P14474: Hydrostatic Test Apparatus
Jake ManleyAnushka KalicharanMitchell SedoreBrian BennerKyle Abbott
![Page 2: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/2.jpg)
Project Overview
Goals● Control pressure, ramp rate,
and time● Test enclosures against
UL1203, UL2225, and CSA 22.2 no. 30
● Control test automatically with minimal operator interaction
Constraints:● Must reuse current fixed
displacement pump● 10,000 psi max pressure● Ability to capture results
during test○ Future Labview Integration
![Page 3: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/3.jpg)
Customer Requirements
Top Customer Requirements ● Test Automation complies with
Standards● Ability to Interface with Current Cooper
Product Line● Ability to Acquire Data from Test● Complete Apparatus for On-Site Testing● Control of Pressure, Hold Time, and
Ramp Rate
![Page 4: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/4.jpg)
Engineering Requirements
![Page 5: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/5.jpg)
Engineering Requirements
Top Engineering Requirements● Deliver Maximum Required Pressure to
Enclosure● Withstand Maximum Internal System
Pressure● Deliver Minimum Required Pressure to
Enclosure● Pressure Ramp Rate● Hold Time for 4X Max Internal Explosion
Pressure● Hold Time for 1.5X Max Internal Explosion
Pressure
![Page 6: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/6.jpg)
Functional Decomposition
![Page 7: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/7.jpg)
Functional Decomposition
![Page 8: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/8.jpg)
Functional Decomposition
![Page 9: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/9.jpg)
Functional Decomposition
![Page 10: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/10.jpg)
Concept Selection
![Page 11: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/11.jpg)
Alternatives Considered
● Hold Components: Manifold vs. Inline● Data Transmission: Wired vs. Wireless● Test Control: Hybrid (Digital and
Manual) vs. Strictly Digital.
![Page 12: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/12.jpg)
Manifold vs. Inline Design for Holding
ComponentsManifold
● Pro’s○ Compact, single unit○ Less plumbing
connections■ Less
opportunities for leakage
● Con’s○ Large manifold
■ Difficult to manufacture
○ Less flexibility in component placement
Inline● Pro’s
○ Flexible location of components
○ Small components■ Easy to
manufacture
● Con’s○ More parts and
connections
![Page 13: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/13.jpg)
Ranking of Manifold vs. Inline
![Page 14: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/14.jpg)
Wired vs. WirelessMethod for Data Transmission
Wired● Pro’s
○ Simple○ Reliable○ Inexpensive○ Secure
● Con’s○ Requires Physical
Routing○ Possible Data loss
due to Wire Damage
Wireless● Pro’s
○ Easy to add Components
● Con’s○ Expensive○ Less Secure○ Susceptible to
Interference
![Page 15: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/15.jpg)
Ranking of Wired vs. Wireless
![Page 16: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/16.jpg)
Hybrid vs. Strictly DigitalManner of Test Control
Hybrid● Pro’s
○ Fail-Safe○ Full Automation○ Allows for Manual
Override
● Con’s○ More Components○ More Complexity
Strictly Digital● Pro’s
○ More Compact○ Full Automation
● Con’s○ No Backup System
![Page 17: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/17.jpg)
Ranking of Hybrid vs. Strictly Digital Controller
![Page 18: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/18.jpg)
Selected Concept Overview
![Page 19: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/19.jpg)
System Controller Overview
![Page 20: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/20.jpg)
Risk Analysis
![Page 21: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/21.jpg)
Risk Analysis
Highest Risk
![Page 22: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/22.jpg)
Testing Plan
● Pressure Sensor(s)○ Apply varying pressures to sensor(s) to verify
output matches expected values.○ Calibrate sensor(s) as necessary.
● Structural Integrity of Piping and Hose.○ Perform calculations to determine
approximate pressure for conduit failure.○ Simulate stress experienced by conduit with
finite element model if deemed necessary from calculations.
![Page 23: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/23.jpg)
Testing Plan
● System Controller○ Simulate logic before programming the controller
to debug as necessary.○ Apply stimulus to controller to recreate input from
pressure sensor and observe output waveforms to verify functionality.
● Pressure Control System○ Apply stimuli to pressure controller to simulate
input from test controller to verify functionality and response time.
○ Attach to test controller and apply stimuli to controller.■ This simulates input from pressure sensor and
can be used to verify reaction time and functionality of pressure controller.
![Page 24: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/24.jpg)
Project Timeline
![Page 25: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/25.jpg)
Questions?
![Page 26: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/26.jpg)
BACKUP SLIDES
![Page 27: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/27.jpg)
What is a Hydrostatic Test?
● Tests structural integrity of the product
○ Product: Electrical enclosures
○ Simulates explosion within the electrical enclosure
● �High Pressure Tests :
○ Proof Test
■ Hold time at specified pressure
○ Destructive Test
■ Test to failure
■ Determines safety factor (UL Standards)
![Page 28: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/28.jpg)
Standards
● �UL1203
○ Electrical enclosure: 10 sec hold time without rupture
○ Safety factor of 4x internal explosion pressure
● �UL2225
○ Cable sealing: 10 sec hold time w/o rupture
○ Safety factor of 4x internal explosion pressure
○ Pressure: 100-600psi/min
● CSA22.2 no.30
![Page 29: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/29.jpg)
Current Hydrostatic Test Apparatus
● �Fully functional
● �Manually controlled by technicians
● �Analog pressure and time measurements
● �Isolated Test Environment
● �Follows standards:
○ UL1203
○ �UL2225
○ �CSA22.2 no.30
![Page 30: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/30.jpg)
Project Deliverables
● �Hardware
○ �Complete onsite test apparatus
● �Documentation
○ Maintenance Recommendations
○ �Model for fatigue predictions
○ �User guide for operation
○ �Engineering Drawings
![Page 31: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/31.jpg)
Stakeholders
● �Cooper-Crouse Hinds
○ Joe Manahan
○ �Lab Technicians
○ �Secondary Customers
● RIT
○ MSD Group
○ �Ben Varela
○ �Mike Zona
![Page 32: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/32.jpg)
Customer Requirements
![Page 33: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/33.jpg)
Engineering Requirements
![Page 34: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/34.jpg)
House of Quality
![Page 35: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/35.jpg)
Photos
![Page 36: P14474: Hydrostatic Test Apparatus Jake Manley Anushka Kalicharan Mitchell Sedore Brian Benner Kyle Abbott](https://reader035.vdocument.in/reader035/viewer/2022062314/56649dc45503460f94ab7637/html5/thumbnails/36.jpg)
Photos