    Tanjung Jati B Training

    PA-FD-ID Fans

  • 8/21/2019 PA-FD-ID Fans

    2/53

    Tanjung Jati B Training

    Boiler Precipitator FGD Absorber

    2 x 660MW (net)

    P.T. Central Java PowerTanjung Jati B Units 1 & 2

  • 8/21/2019 PA-FD-ID Fans

    3/53

    Tanjung Jati B Training

    OPERATIONS

    PA-FD-ID FANS

  • 8/21/2019 PA-FD-ID Fans

    4/53

    Tanjung Jati B Training

    PA-FD-ID FansLocation

    PA FANS ID FANSFD FANS

  • 8/21/2019 PA-FD-ID Fans

    5/53

    Tanjung Jati B Training

    PA-FD-ID FansFunction

    The fans serve to provide the following regarding

    The operations of the Boiler, ESP & FGD Systems

    FD FANS: Combustion Air for the Burners

    ID FANS: Remove Flue Gas from the Boiler & ESP

    and force the flue gas through the

    FGD System to the Stack

    PA FANS: Provide air for the operation of the

    Pulverizers and transport of pulverized

    coal to the Burners

  • 8/21/2019 PA-FD-ID Fans

    6/53

    Tanjung Jati B Training

    PA-FD-ID Fans

    Forced Draft (FD)

    Induced Draft (ID)

    Primary Air (PA)

  • 8/21/2019 PA-FD-ID Fans

    7/53

    FD Fans

    Each FD Fan has a single inlet and provide

    50% of the total airrequirement at Boiler

    Maximum Continuous Rating firing Bengalon

    Coal at 1% sulfur.

    The FD Fans are theAxial type versus the

    Centrifugal type PA and ID Fans.

    Air flow through the fan is controlled by theVariable Pitch Blades.

    Tanjung Jati B Training

  • 8/21/2019 PA-FD-ID Fans

    8/53

    FD FansAxial Design

    MOTOR

    INLET BOX

    AIR FLOW BLADES

    DIFFUSER

    LUBE AND/OR

    HYDRAULIC UNIT

    STRAIGHTENING

    VANES

    OUTLET AIR

    Tanjung Jati B Training

  • 8/21/2019 PA-FD-ID Fans

    9/53

    FD Fans

    Secondary Air System

    FD Fan

    FD Fan

    SCAH

    SCAH

    Air Heater

    Air Heater

    Air Foil B

    Air Foil A

    Burner Level

    Windbox

    (typical)

    Inlet

    Silencer

    Screen

    N

    Tanjung Jati B Training

    Hot Crossover

    Duct

  • 8/21/2019 PA-FD-ID Fans

    10/53

    Tanjung Jati B Training

    ID FansFan Bearings

    The ID Fans have sleeve-type bearings which

    require continuous water flow for cooling.Water is supplied by the Closed Circuit Cooling

    Water (CCCW) system.

    The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,

    most likely cooling water has entered the oil

    cavity and has contaminated.

  • 8/21/2019 PA-FD-ID Fans

    11/53

    FD Fans

    Some Components and Terms to remember

    Variable Pitch Blades

    Hydraulic-Lube Unit

    Fan Stall

    Tanjung Jati B Training

  • 8/21/2019 PA-FD-ID Fans

    12/53

    Tanjung Jati B Training

    FD FansVariable Pitch Blades

    Variable Pitch Blades, internal to the Fan

    Housing are used to control air flow through

    the fan.

    A stand alone Hydraulic Oil Unit provides thenecessary oil pressure to adjust the pitch of

    the Blades.

  • 8/21/2019 PA-FD-ID Fans

    13/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    The Hydraulic Unit serves two functions

    Adjust the pitch of the Blades

    Provide Lube Oil for the Fan Bearings

  • 8/21/2019 PA-FD-ID Fans

    14/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    The Hydraulic Oil Unit consists of the following

    Local Control Cabinet

    Two (2) motor-driven oil pumps

    Oil HeaterOil Cooler

    Oil Sump

    Filters

    Instrumentation (Flow switch, Level switch)

  • 8/21/2019 PA-FD-ID Fans

    15/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    The Control Cabinet has the following features

    Indication Lamps

    Oil Pump Status

    Oil Heater StatusHigh/Low Oil Temperature

    Low Oil Level

    Low Oil Flow

    Low Oil Pressure

  • 8/21/2019 PA-FD-ID Fans

    16/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    The Control Cabinet has the following features

    Buttons & Switches

    Oil Pump Select

    Oil Pump StartOil Pump Stop

    Oil Pump Hand/Off/Auto (x2)

    Alarm Reset

  • 8/21/2019 PA-FD-ID Fans

    17/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    The Oil Pumps are interlocked such that a

    significant drop in oil pressure from the

    operating pump will start the stand-by

    pump.

  • 8/21/2019 PA-FD-ID Fans

    18/53

    Tanjung Jati B Training

    FD FansHydraulic Unit

    CONTROL PANEL

    OIL SUMP

    OIL PUMPS

  • 8/21/2019 PA-FD-ID Fans

    19/53

    Tanjung Jati B Training

    FD FansStart-Up

    Prior to starting an FD Fan, the Hydraulic Unitmust be available and operating. If the Hydraulic

    Unit panel indicates any alarms, these should be

    investigated and cleared prior to starting the Fan.

    An Induced Draft Fan must be in service prior to

    starting an FD Fan.

  • 8/21/2019 PA-FD-ID Fans

    20/53

    Tanjung Jati B Training

    FD FansAutomatic Operation

    During automatic operation the FD Fan Inlet

    Vanes will control air pressure in the Secondary Hot

    Crossover Duct to the desired set point.

  • 8/21/2019 PA-FD-ID Fans

    21/53

    Tanjung Jati B Training

    FD FansTrip Interlocks

    Fans will trip under the following conditions

    Secondary Air Duct Pressure High-High

    High Fan Bearing Vibration

    High Fan Bearing Oil Temperature

    Furnace Pressure High-High

    Loss of Flow Path

    Loss of Breaker (power failure)High Motor Amps (time delay)

    Hydraulic Oil Unit Failure

  • 8/21/2019 PA-FD-ID Fans

    22/53

    Tanjung Jati B Training

    FD FansShutdown

    Prior to stopping the FD Fan, the fans loading

    should be reduced manually and slowly. This

    wil l allow the other operating FD Fan to maintaincontrol of the Secondary Air Duct pressure.

  • 8/21/2019 PA-FD-ID Fans

    23/53

    Tanjung Jati B Training

    FD FansStall

    Fan stall is a condition where there is a

    sudden and significant drop in the differential

    pressure (air f low) between the fan inlet and outlet.

    A differential pressure transmitter is provided to

    monitor air flow condit ions.

  • 8/21/2019 PA-FD-ID Fans

    24/53

    Tanjung Jati B Training

    FD FansStall

    Fan stall is a serious and potentially danger situation

    which is usually accompanied by vibration and

    increased noise. Fan blade failure can occur.

    When fan stall is suspected, the fan should be

    SHUT DOWN immediately.

  • 8/21/2019 PA-FD-ID Fans

    25/53

    Tanjung Jati B Training

    PA-FD-ID Fans

    Forced Draft (FD)

    Induced Draft (ID)

    Primary Air (PA)

  • 8/21/2019 PA-FD-ID Fans

    26/53

    Tanjung Jati B Training

    ID Fans

    Description

    The Induced Draft (ID) Fans are single-speed,

    double-inlet, centrifugal-type fans.

    The ID Fans operate at a relatively low speed

    compared to the FD Fans and Primary Air Fans.

  • 8/21/2019 PA-FD-ID Fans

    27/53

    Tanjung Jati B Training

    ID Fans

    Function

    The ID Fans remove flue gas from the Boiler and the

    Precipitator and force those flue gasses through the

    FGD System to the stack.

  • 8/21/2019 PA-FD-ID Fans

    28/53

    Tanjung Jati B Training

    PA-FD-ID FansLocation

    PA FANS ID FANSFD FANS

  • 8/21/2019 PA-FD-ID Fans

    29/53

    Tanjung Jati B Training

    ID FansOperation

    ID Fans, serve to control Furnace Draft Pressure

    during Unit operation. During start-up of the Boiler,

    the ID Fan Inlet vanes and Start-Up Damperwork in

    unison to control the flow through the ID Fan.

  • 8/21/2019 PA-FD-ID Fans

    30/53

    ID Fans

    Flue Gas System

    Tanjung Jati B Training

    Man-Safe

    Double Dampers

    with Seal Air Tri-Sector

    Air Heaters

    Precipitators

    Boiler

    ID Fans

    Start-Up

    Control Damper

    Guillotine Isolation

    Damper with Seal Air

    To FGD

  • 8/21/2019 PA-FD-ID Fans

    31/53

    Tanjung Jati B Training

    ID FansFan Bearings

    The ID Fan have sleeve-type bearings which

    require continuous water flow for cooling.Water is supplied by the Closed Circuit Cooling

    Water (CCCW) system.

    The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,

    most likely cooling water has entered the oil

    cavity and has contaminated.

  • 8/21/2019 PA-FD-ID Fans

    32/53

    Tanjung Jati B Training

    ID FansStart-Up

    Prior to starting an ID Fan, an operator should

    check the oil level in the bearing and be sure

    that the CCCW isolation valves are open.

    Be sure all housing doors are closed and anoperator should be present when the fan is started.

  • 8/21/2019 PA-FD-ID Fans

    33/53

    Tanjung Jati B Training

    ID FansStart-Up

    When the ID Fan is commanded to start, the

    fans Outlet Isolation Guillotine Damperwillclose. Once the dampers close limit switch

    is activated the fan will start. The isolation

    damper will open after a time delay.

    After the ID Fan is started, the operator will

    manually modulate both the FD & ID Fans to

    achieve the desired air f low and furnace

    pressure prior to putting control in automatic.

  • 8/21/2019 PA-FD-ID Fans

    34/53

    Tanjung Jati B Training

    ID FansAutomatic Operation

    The ID Fans inlet vanes modulate to controlFurnace Pressure only.

    If two fans are running and one trips, the

    remaining ID fan will control Furnace Draftwhile the unit runs back or reduces load

    towards 50%.

  • 8/21/2019 PA-FD-ID Fans

    35/53

    Tanjung Jati B Training

    ID FansAutomatic Operation

    How does an operator know both fans areoperating at the same load?...

    The motor running amps wil l be the same!

  • 8/21/2019 PA-FD-ID Fans

    36/53

    Tanjung Jati B Training

    ID FansTrip Interlocks

    Fans will trip under the following conditions

    High Fan Bearing Vibration

    High Fan Bearing Oil Temperature

    Furnace Pressure High-HighLoss of Flow Path

    Loss of Breaker (power failure)

    High Motor Amps (time delay)

  • 8/21/2019 PA-FD-ID Fans

    37/53

    Tanjung Jati B Training

    ID FansShutdown

    Similar to the FD Fan, the inlet vane controls

    should be put into manual and the Inlet Vanes

    should be closed slowly. When the fan is at

    minimum loading, the fan can be stopped.

  • 8/21/2019 PA-FD-ID Fans

    38/53

    Tanjung Jati B Training

    PA-FD-ID Fans

    Forced Draft (FD)

    Induced Draft (ID)

    Primary Air (PA)

  • 8/21/2019 PA-FD-ID Fans

    39/53

    Tanjung Jati B Training

    PA-FD-ID Fans

    Location

    PA FANS ID FANSFD FANS

  • 8/21/2019 PA-FD-ID Fans

    40/53

    Primary Air (PA) FansFunction

    Two (2) 60% capacity, single-speed,

    centrifugal-type primary air fans are neededfor the following

    Circulation of coal in the pulverizers

    Hot air to dry the coal

    Transport pulverized coal to the burners

    Primary air accounts for approximately 25%

    of the air flow required for combustions

    Tanjung Jati B Training

  • 8/21/2019 PA-FD-ID Fans

    41/53

    Primary Air

    Tanjung Jati B Training

    MILL A

    MILL B

    MILL C

    MILL D

    MILL E

    MILL F

    PA Fans

    Inlet Screen

    and Silencer

    Isolation

    Dampers

    Cold Air Duct

    Hot Air

    Duct

    Tri-Sector

    Air Heater

    Control DampersGuillotine

    Isolation Damper

    To Seal

    Air Fans

    Air Measurement

  • 8/21/2019 PA-FD-ID Fans

    42/53

    Tanjung Jati B Training

    PA Fans

    Fan Bearings

    The PA Fans have sleeve-type bearings which

    require continuous water flow for cooling.

    Water is supplied by the Closed Circuit Cooling

    Water (CCCW) system.

    The bearing are also equipped with a oil levelsite gauge. If the oil appears cloudy or frothy,

    most likely cooling water has entered the oil

    cavity and has contaminated.

  • 8/21/2019 PA-FD-ID Fans

    43/53

    Tanjung Jati B Training

    PA Fans

    Fan Motors

    The PA Fan Motors have oil-lubricated bearings

    which requires a stand alone lube oil skid. One

    lube oil skid supplies oil to both motors.

  • 8/21/2019 PA-FD-ID Fans

    44/53

    Tanjung Jati B Training

    PA Fans

    Fan Motor Lube Oil Skid

    The lube skid has very similar components

    to the FD Fan oil skid

    Two (2) Oil Pumps

    Oil Sump

    Filters

    Air Cooler

    Oil Pressure & Temperature Switches

    GaugesJunction Box

    PA F

  • 8/21/2019 PA-FD-ID Fans

    45/53

    Tanjung Jati B Training

    PA Fans

    Start-Up

    Prior to starting an PA Fan, an operator should

    check the oil level in the bearing and be surethat the CCCW isolation valves are open.

    Be sure all housing doors are closed and an

    operator should be present when the fan is started.

    PA F

  • 8/21/2019 PA-FD-ID Fans

    46/53

    Tanjung Jati B Training

    PA Fans

    Start-Up

    Prior to starting an PA Fan, an operator should

    also check to be sure that the Motor Lube OilSkid is started and functioning properly (no alarms).

    PA F

  • 8/21/2019 PA-FD-ID Fans

    47/53

    Tanjung Jati B Training

    PA Fans

    Start-Up

    Prior to starting a pulverizer, a PA must be started

    first. When the fan is commanded to start, the fansOutlet Isolations Damper will be commanded to close.

    once the Dampers closed limit switch is activated,

    the PA Fan starts. After a specified time delay, the

    Outlet Isolation Damper opens.

    PA F

  • 8/21/2019 PA-FD-ID Fans

    48/53

    Tanjung Jati B Training

    PA Fans

    Automatic Operation

    The loading of the PA Fans is controlled by variableInlet Vanes. This is determined by the Primary Air

    Hot Crossover Duct Pressure Set Point.

    If two fans are in service and one trips, the Boiler

    load will runback to approximately 60% load.

    PA F

  • 8/21/2019 PA-FD-ID Fans

    49/53

    Tanjung Jati B Training

    PA Fans

    Trip Interlocks

    Fans will trip under the following conditions

    Boiler MFT (pulverizers tripped)

    High Fan Bearing Vibration

    High Fan Bearing Oil TemperatureLoss of Flow Path

    Loss of Breaker (power failure)

    High Motor Amps (time delay)

    PA F

  • 8/21/2019 PA-FD-ID Fans

    50/53

    PA FansShutdown

    Tanjung Jati B Training

    Similar to the other fans, the inlet vane controlsshould be put into manual and the Inlet Vanes

    should be closed slowly. When the fan is at

    minimum loading, the fan can be stopped.

    PA F

  • 8/21/2019 PA-FD-ID Fans

    51/53

    PA FansShutdown

    Tanjung Jati B Training

    Once the last pulverizer has been shutdown,the Primary Air Fans can be stopped.

    PA FD ID Fans

  • 8/21/2019 PA-FD-ID Fans

    52/53

    PA-FD-ID Fans

    General Start-Up Sequence

    Tanjung Jati B Training

    The start-up sequence for the fans is as follows.This assumes all fans are available

    ID Fan A or ID Fan B

    FD Fan A FD Fan B

    ID Fan B ID Fan A

    FD Fan B FD Fan A

    PA Fans A/B (prior to starting a pulverizer)