pag 1 a4 - Προϊόνταchemofluid.gr/pdf-files/emec/catalogo piscina_inglese_31-01-2011.pdf ·...

15
1 POOLS CATALOGUE

Upload: duongdat

Post on 10-May-2018

216 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

1

POOLS CATALOGUE

Page 2: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

2

DESIGN. PRODUCTION. CONSULTING.THERE’S A WHOLE WORLD WITHIN.

Page 3: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

2 3

SUSTAINABILITY

Respecting and safeguarding the environment are the core values underpinning our business. In keeping with that commitment we engage in and promote all actions designed to curb the environmental impact of our processes, products and raw materials, on a life-cycle basis. Our company implements an Environmental Management System compliant with UNI ENI ISO 14001 standards, subject to ongoing updates. Our goal is to curb atmospheric emissions, rationalise water consumption and enact appropriate waste management policies. Environmental impact assessments cover new products, process innovations and public tenders.We are committed to providing our employees and staff with appropriate information and training concerning our company policy and its implementation with respect to both the workplace and our products.

CERTIFIED SKILLS AND VALUES

EMEC’s values and reliability are the result of a long-standing commitment to quality and detail. We testify to that commitment through ongoing human resources training, rigorous abidance by production benchmarks, and concerted efforts to curb all employee health hazards. Our pledge is a firm one and is backed by our policy implementation and investment goals. Our global quality approach matches our market standing and is certified by the world’s leading certification institutes.

THIRTY YEARS OF LEADERSHIP

EMEC ranks among Italy’s top, consolidated industrial actors in the field of electronic control systems for fluids metering and management applications. Our products are designed and manufactured for both industrial and small-scale applications.We are an all-Italian business entity with a clear strategic outlook, right from the outset, striving to merge design innovation with a long-term industrial footing. Our high-precision, hi-reliability products are entirely designed and assembled at our Rieti facilities.EMEC’s reputation as a market leader is expanding both in Italy and internationally, boosting demand for our quality, Italian designer products.

EVERYTHING UNDER CONTROL

Our products are supported by passion and a solid industrial background. At EMEC, we have always sought to identify and seize investment opportunities, committing our resources to technology and human resources. That key to our success - and what sets us apart from market competitors - is our complete control of the production cycle, reliant on specialist business set-ups and resources. Our approach feeds into all aspect ahead of end product delivery: systems design, component production and assembly, software programming and final testing. In line with total quality commitments, we provide installation and maintenance specialists with up-to-date training for both our household and industrial products.Our retail and commercial units operate with a technical mindset, encompassing a firm grounding in all aspects of design and production; as such, they stimulate product innovation and enhancements based on Customer requirements, feedback and field experience. That approach makes us ideal partners when it comes to delivering targeted solutions to specific requirements. Our claims are anything but overstated: complete control, to us, is the only viable approach to ensuring total product quality and effective service delivery.

A CONSTANLY EVOLVING WORLD

Our 30-year industrial footing has bred constant improvements in all our products, expanding range and functions. Our range of products is currently implemented in a broad range of settings:

● Industrial water treatment● Drinking water processing● Industrial water effluents processing● Chemical and mechanical water purification● Bacterial water purification● Liquid fertilisation and irrigation● Chemicals processing● Industrial food processing● Cooling towers● Refineries● Health spas ● Swimming pools ● Car washes

EMEC WORLDWIDE

ISO 9001:2008OHSAS 18001:2007ISO 14001:2004

Page 4: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

4 5

• pH / Redox measurement and control

MULTIFUNCTION PUMPS(Constant, Divide, Multiply, PPM, Batch, Volt,mA, %, ml/q), stand-by*, and flow sensor input*, alarm output** and level control.

• Level and flow control

AMS MF

KMS MF

TMS MF

VMS MF

Dosing pumps

CONSTANT PUMPS

*Not

ava

ilabl

e on

mod

. VM

S M

F **

Exte

rnal

ala

rm a

vaila

ble

on d

eman

d on

mod

. VM

S M

F an

d m

od. V

CL

AMS CL

KCL

TCL

VCL

TMS PH

TMS RH

VMS PH - VMS RH

VPHE - VRHE

FMS EV

Pressurebar

Flowl/h

7 20

3 40

2 60

Stroke lenght andstroke speed adjustment

Pressurebar

Flowl/h

2 18

5 10

20 01

Stroke lenght andstroke speed adjustment

Pressurebar

Flowl/h

4 20

31

3050

Stroke speed adjustment

Pressurebar

Flowl/h

5 1

10 4

3 10

2 17

Stroke speed adjustment

Proportional pump driven by internal built-in pH meter (0÷14pH) stand-byand level control, supplied withoutpH probe.

Proportional pump driven by internalbuilt-in ORP (ORP) meter (0÷1000mV) stand-by and level control, supplied without ORP probe.

VMS PHProportional pump driven by internal built-inpH meter (0÷14pH) and level control,supplied without pH probe.PVDF pump head and accessories.

VMS RHProportional pump driven by internalbuilt-in ORP (ORP) meter (0÷1000mV)and level control,supplied without ORP probe.PVDF pump head and accessories.

VPHEProportional pump driven by internal built-in pH meter (6.8÷7.4pH) and level control,supplied without pH probe. LED display.PVDF pump head and accessories.

VRHEProportional pump driven by internal built-in ORP meter (660÷740mV) and level control,supplied without pH probe. LED display.PVDF pump head and accessories.

Proportional controller for ORP with output for disinfectant or salt chlorine generator.

Pressurebar

Flowl/h

4 20

3 30

Pressurebar

Flowl/h

4 20

31

3050

Pressurebar

Flowl/h

5 1

10 4

3 102 17

Pressurebar

Flowl/h

2 2

Solenoid ValveVAC

ConsumptionA

230 10

Page 5: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

6 7

• Dosing and controlling systems for dry feeder and salt chlorine generator

• pH and active oxygen measurement and control

WDPHCA

WDPHCF

• Multiple parameters measurement and control

Dosing pumps

WDPHCL

WDPHRH

WDPHCLS - WDPHRHS WDPHOS

pH & Chlorine

Swimming pool controller with 2metering pumps for acid (pH) andchlorine (Cl).

Ranges: 0 - 14 pH0 - 10 mg/l Cl2.Chlorine probe to specify at order.Controller settings by wheel. LCDbacklight display.

Alarm output, max dosing timealarm, probe check-up, pH prioritydosing. Liquid ends in PVDF.

pH & Redox (ORP)

Swimming pool controller with 2metering pumps for acid (pH) anddisinfectant (ORP).

Ranges: 0 - 14 pH0 - 1000 mV.Controller settings by wheel. LCDbacklight display.

Alarm output, max dosing timealarm, probe check-up, pH prioritydosing.Liquid ends in PVDF.

pH / Redox (ORP) & EV

Proportional control and dosing pump driven by internal built-in pH, Redox and Chlorine/Bromine meter.PVDF pump head and accessories. Exit (SCHUKO plug) for sterilisers or Cl/Br feeders.

Ranges: 0 - 14 pH 0 - 10 mg/l Cl2 / Br2

Also available in pH /Redox version (WDPHRHS).

Ranges:0 - 14 pH0 - 1000 mV

Pressurebar

Flowl/h

5 1

3 10

Pressurebar

Flowl/h

5 1

3 10

Pressurebar

Flowl/h

5 1

3 10

Section pH / Redox

Solenoid ValveVAC

ConsumptionA

230 10

Proportional control and dosing pump with two in-built pH and anti-algae pumps. Output to 230 VAC solenoid valve and on/off switch for Cl/Br feeders. Weekly anti-algae timer.

Rotational ENCODER.PVDF pump head and accessories.

Ranges:0 - 14 pH0 - 10 mg/l Cl2

Pressurebar

Flowl/h

3 10

Proportional control and dosing pump with two built-in pH and flocculant pumps . Output to 230 VAC solenoid valve and on/off switch for Cl/Br feeders. Dosing units: g/day

Rotational ENCODER.PVDF pump head and accessories.

Ranges:0 - 14 pH0 - 10 mg/l Cl2

Pressurebar

Flowl/h

3 10(pH section)

Pressurebar

Flowl/h

3 10(pH section)

3 4(active oxygen

section)

Proportional control and dosing pump with two built-in pH and active oxygen pumps. Temperature control via provided probe. Active oxygen timer settings adjustable weekly and daily (hourly basis).PVDF pump head and accessories.Parameter settings:- quantity/m3 @ 25°C- quantity/m3 @ 30°C- pool volume Rotational ENCODERRange: 0 - 14 pH

Page 6: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

8 9

Dechloration system for filters cleaning waters. It works with a pulse sender water meter (1.1/2” or da 2” size).

Proportional volume control (product ppm) with level meter.

Foot-bath disinfection system. It works with a pulser sender water meter (1/2” size).

% control with level probe.

Foot-bath disinfection system. It works with a pulser sender water meter (1/2” size).

% control with level probe.

Dechlorination system for Chlorine filter waters. Level meter provided.

Volume settings:- 0-800 gr/h- 0-8000 gr/h

VMS MF

CTFI

• pH and active oxygen measurement and control

• Scent and essences dosing for health spas

• Foot-bath disinfection systems

• Dechloration system for filters cleaning waters

Dosing pumps

FLOCCULANT

Metering pump for flocculant withdouble measurement scale (24h)

From 0 to 300 gr/dayFrom 0 to 3000 gr/day

* With level probe

SCENT AND ESSENCES DOSING

Silenced pump for scent and essences dosing at spas and hammam centres. Level probe provided.2-scale parameter settings:- 0-100 g/hr- 0-1000 g/hr

SCENT AND ESSENCES DOSING C.E.

Silenced pump for scent and essences dosing at spas and hammam centres. Level probe provided. External input socket (N.O.). 2-scale parameter settings:- 0-100 g/hr- 0-1000 g/hr

ALGICIDE

Anti-algae pump with a weekly timer for shock-type water treatment. Quantities adjustable in cc units.

ACTIVE OXYGEN Active oxygen pump, temperature and level control probes provided.

Settings:- day/week timer- temperature compensation- pool volume

Pressionebar

Portatal/h

5 8

Pressurebar

Flowl/h

3 30

Pressurebar

Flowl/h

3 10

Pressurebar

Flowl/h

3 4

Pressurebar

Flowgr/24h

5 3000

Pressurebar

Flowl/h

7 1

Pressurebar

Flowl/h

7 1

Pressurebar

Flowl/h

3 10

2 17

CTFI 1/2”

CTFI 1.1/2”CTFI 2”

VMS EN

VMSA H2O2

VCOG - VCLG*

VCLS

VCLSE

VCLD

CTFI

CTFIVMS MF

TMS MF

Pressurebar

Flowl/h

5 12

CTFI 1/2”

Page 7: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

10 11

Control Led via a rotational encoder• Digital controllers for swimming pools parameters control: pH - Redox - Cl2 - °C - Br2 - O3 - Total chlorine - H2O2

Single parameter digital instruments Multi-parameter digital instruments• Simultaneous multi-parameter measurement and control

LDxx Series Digital Controllers

Digital controller with automatic temperature compensation (ETEPT probe, not included). LCD backlight display. Outputs: On/Off, proportional digital, max dosing time alarm, chart recorder output (0-20 or 4-20), serial port for printer or GSM Modem, probe cleaning output. Inputs: pulse emitter water meter input, product levels,stand-by, flow.

RS232/485 serial port.“SMS alarm” ready. IP65 housing.

LDPH pH (0÷14 pH), °C (0÷150) LDRH ORP (-1000÷+2000 mV), °C (0÷150) LDCL Free chlorine, Chlorine, Oxygen Peroxide, Ozone, Bromine (based on choosen probe), °C (0÷150)

Single unit controller for: pH or ORP or Conductivity or Chlorine or Ozone or Dissolved Oxygen or Chlorine Dioxide or H2O2 and Temperature. Automatic temperature compensation (ETEP probe, not included).Two On/Off set points. 0÷20 mA or 4÷20 mA output proportional to measured value.

RACK mounting(48x96mm)

RAIL mounting(6 moduli)

JC SERIES J DIGITAL SERIES DIN DIGITAL SERIES

RACK mounting(96x96mm)

LDPHxx Series

Digital controller with microprocessor and backlit LCD display. Rotational ENCODER. 3 proportional pulses setpoints and 2 proportional On/Off or timered (PWM). Stand-by input; max dosing time alarm, probe failure alarm, off-scale parameter alarm. Externally controllable via filter switch. Chlorine/ Bromine selector. General Alarm OutputAdditional features:- USB output port (operations data memorisation)- output current (0/4 - 20 mA)- RS485 output socket

LDPHRH pH (0÷14) - ORP (0÷1000mV) - °C (0÷99,9) LDPHCL* pH (0÷14) - Chlorine (0÷10 mg/l Cl2)* - °C (0÷99,9)LDPHO2 pH (0÷14) - O2 (0÷200 mg/l H2O2) - °C (0÷99,9) *Probe type must be specified upon ordering.

MAX5(pH / Total chlorine / Free chlorine /Combined chlorine / Redox / °C / Turbidity / Conductivity )

MAX5 is a multiple digital controller system. It reads and controls up to 5 channels that can be programmed to control pH - ORP - Chlorine - Turbidity - Temperature - Total Chlorine control.It features 6 setpoint outputs, 6 proportional pump outputs, 5 level tank inputs, 5 flocculant/algicide dosing timer, water meter input for water restore, alarm output. MAX5 can be connected to a PCfor pool remote controlling/ programming using a standard USB port or RS485 connection or GSM MODEM. Rotational ENCODER.

Additional features:- USB output port (operations data memorisation)- output current (0/4 - 20 mA)

The MAX5 version features additional proportional output channels (4 ÷20 mA).

All information are provided through a widescreen LCD display (240x64). Using a revolutionary wheel the controller can be easily programmed. Self-installing communication software.

MAX5 working ranges are:

pH: from 0 to 14 pHORP (Redox): from 0 to 1000 mVTotal Chlorine: from 0 to 10 mg/lFree Chlorine: from 0 to 10 mg/l

Combined Chlorine: from 0 to 10 mg/lTurbidity: from 0 to 30 NTUTemperature: from 0 to 100 °CConductivity: from 0 to 300 mS

Page 8: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

12 13

1 1

22

33

44

5 5

Complete control and dosing systems

PA- PHH2O2 PA- PHRH PA- WDPHRH PA- WDPHEV

1 12 2

3 34 45 5

6 6

Proportional pH or Redox control.Dry feeder and steriliser output (230VAC / 10A).

1. Controller WDPHRHS 07 06 (6 l/h) or 05 01 (1 l/h)2. NFIL Filter3. Probe Redox ERHS4. Probe pH EPHS5. Probe Holder NPED4

Dimensions: 400x600 mmPre-assembled panel.Available with customized / coloured background

Proportional pH and Redox control.

1. Controller WDPHRH 03 10 (10 l/h) or 05 01 (1 l/h)2. NFIL Filter3. Probe Redox ERHS4. Probe pH EPHS5. Probe Holder NPED4

Dimensions: 400x600 mmPre-assembled panel.Available with customized / coloured background

For pH proportional controland active oxygen.

1. Dosing Pump VMS PH 07 06 (6 l/h)2. Dosing Pump VMS H2O2 03 04 (4 l/h)3. NFIL Filter4. Temperature Probe5. Probe pH EPHS6. Probe Holder NPED4

Dimensions: 400x600 mmPre-assembled panel.Available with customized / coloured background

For pH proportional controland Chlorine (Redox).

1. Dosing Pump VMS PH 07 06 (6 l/h)2. Dosing Pump VMS RH 07 06 (6 l/h)3. NFIL Filter4. Probe Redox ERHS5. Probe pH EPHS6. Probe Holder NPED4

Dimensions: 400x600 mmPre-assembled panel.Available with customized / coloured background

Page 9: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

14 15

• pH / Chlorine treatment

PA-WDPHCL

PA-WDPHCLO

1

2 3

4

5

1

2 3

4

6

5

Complete control and dosing

1

2

3

4

5

PA-WDPHCFSA / PA-WDPHCASAPA-WDPHCFBR / PA-WDPHCABR

For proportional pH and chlorine.

1. Controller WDPHCL 07 06 (6 l/h) or 05 01 (1 l/h)2. NFIL Filter3. Proximity sensor SEPR4. Probe pH EPHS5. Open amperometric cell ECL6

Dimensions: 500x700 mmPre-assembled panel.Available with customized / coloured background

Chlorine

Inorganic and organic chlorine.

For proportional pH and chlorine (inorganic and organic).

1. Controller WDPHCL 07 06 (6 l/h) or 05 01 (1 l/h)2. NFIL Filter3. Proximity sensor SEPR4. Probe pH EPHS5. Probe chlorine ELC3S/106. Probes holder PEF1

Dimensions: 500x700 mmPre-assembled panel.Available with customized / coloured background

Salt sterilizer version: - Flocculant PA-WDPHCFSA- Algicide PA-WDPHCASA

1. Controller WDPHCA 07 06 (6 l/h) or 05 01 (1 l/h)2. Probe Redox EPHS3. NFIL Filter4. Proximity sensor SEPR5. Amperometric cell ECL6

Dimensions: 500x700 mmPre-assembled panel.Available with customized / coloured background

Bromine dry feeder version: - Flocculant PA-WDPHCFBR- Algicide PA-WDPHCABR

1. Controller WDPHCL 07 06 (6 l/h) or 05 01 (1 l/h)2. Probe Redox EPHS3. NFIL Filter4. Proximity sensor SEPR5. Amperometric cell ECL6

Dimensions: 500x700 mmPre-assembled panel.Available with customized / coloured background

Page 10: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

16 17

PA- LDPHCLOB

PA- LDPHCLOBG

1

1

4

5

6

7

8

2 3

4

5

6

8

7

2 3

• LDPHCL controller based system with open amperometric cell ECL6

Control and dosing

PA- LDPHCL

PA- LDPHCLO

1 2

4

5

6

8

7

3

1 2

3

4

5

6

7

For pH and chlorine proportional control.Large size swimming pool.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 02 17 (17 l/h)3. Dosing Pump chlorine GMS MF 03 30 (30 l/h)4. NFIL Filter5. Probe pH EPHS6. Proximity sensor SEPR7. Temperature probe ETEPT8. Open amperometric cell ECL6

Dimensions: 800x800 mmPre-assembled panel.Available with customized / coloured background

For pH and chlorine proportional control.Large size swimming pool.

1. Controller LDPHCL2. Dosing Pump acid GMS MF 03 30 (30 l/h)3. Dosing Pump chlorine GMS MF 01 50 (50 l/h)4. NFIL Filter5. Probe pH EPHS6. Proximity sensor SEPR7. Temperature probe ETEPT8. Open amperometric cell ECL6

Dimensions: 800x800 mmPre-assembled panel.Available with customized / coloured background

To use with dry feeder (chlorine / bromine) or sterilizer. Medium size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 03 10 (10 l/h)3. NFIL Filter4. Probe pH EPHS5. Proximity sensor SEPR6. Temperature probe ETEPT7. Open amperometric cell ECL6

Dimensions: 600x800 mmPre-assembled panel.Available with customized / coloured background

For pH and chlorine proportional control. Medium size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 03 10 (10 l/h)3. Dosing Pump chlorine VMS MF 02 17 (17 l/h)4. NFIL Filter5. Probe pH EPHS6. Proximity sensor SEPR7. Temperature probe ETEPT8. Open amperometric cell ECL6

Dimensions: 600x800 mmPre-assembled panel.Available with customized / coloured background

Page 11: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

18 19

PA- LDPHCLVG

PA- LDPHCLGD

1 2 3

4 5

8

76

1 2 3

4 5

8

6 7

• LDPHCL controller based system with closed amperometric cell ECL3S/10 and PEF1

Control and dosing

PA- LDPHCLV

PA- LDPHCLVD

1

1

6

45

9

8 7

2 3

3

5

4

8

7 6

2

For dosing and controlling proportional pH and chlorine (inorganic and organic).For big-size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 02 17 (17 l/h)3. Dosing Pump chlorine GMS MF 03 30 (30 l/h)4. NFIL Filter5. Proximity sensor SEPR6. Probe pH EPHS7. Probe chlorine ECL3S/108. Probes holder PEF1

Dimensions: 800x800 mmPre-assembled panel.Available with customized / coloured background

For dosing and controlling proportional pH and chlorine (inorganic and organic).For mid-size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid GMS MF 03 30 (30 l/h)3. Dosing Pump chlorine GMS MF 01 50 (50 l/h)4. NFIL Filter5. Proximity sensor SEPR6. Probe pH EPHS7. Probe chlorine ECL3S/108. Probes holder PEF1

Dimensions: 800x800 mmPre-assembled panel.Available with customized / coloured background

To use with dry feeder or salt chlorine generator. For mid-size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 03 10 (10 l/h)3. NFIL Filter4. Proximity sensor SEPR5. Probe pH EPHS6. Probe chlorine ECL3S/107. Temperature probe ETEPT8. Probes holder PEF1

Dimensions: 600x800 mmPre-assembled panel.Available with customized / coloured background

For dosing and controlling proportional pH and chlorine (inorganic and organic).For mid-size swimming pools.

1. Controller LDPHCL2. Dosing Pump acid VMS MF 03 10 (10 l/h)3. Dosing Pump chlorine VMS MF 02 17 (17 l/h)4. NFIL Filter5. Proximity sensor SEPR6. Probe pH EPHS7. Probe chlorine ECL3S/108. Temperature probe ETEPT9. Probes holder PEF1

Dimensions: 600x800 mmPre-assembled panel.Available with customized / coloured background

Page 12: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

20 21

• LAN - GPRS/GSM - Webserver with HOSTING service

Worldwide controlling systemAdvanced complete systems

PA-M5D

1 2 3

5

47

10

6

8 9

PA-M5DB

1

7 89

10 11

612

13

2 3 4 5

PA-M5DV

MAX5

For pH, ORP, Free chlorine and Temperature

1. Controller MAX52. Dosing Pump acid VMS MF 03 10* (10 l/h)3. Dosing Pump chlorine VMS MF 02 17* (17 l/h)4. NFIL Filter5. Probe EPHS di pH6. Probe ECL3S/10 chlorine libero7. Proximity sensor SEPR8. Temperature probe ETEPT9. Probe ERHS di Redox10. Probes holder PEF1

*GMS pump version (Ordering code PA-M5DG)

Dimensions: 800x800 mm Pre-assembled panel. Available with customized / coloured background

1. Multiparameters controller MAX52. Dosing Pump acid VMS MF 03 10 (10 l/h)3. Dosing Pump chlorine VMS MF 02 17 (17 l/h)4. Dosing Pump flocculante VCLG*5. Dosing Pump anti-alghe VMS EN 07 06* (6 l/h)6. NFIL Filter7. Probe pH EPHS

*not available for panel PA-M5DV

Dimensions: 1000x800 mmPre-assembled panel. Available with customized / coloured background

For pH, ORP, Free chlorine, Chlorine, Combined chlorine, Temperature, Flocculant and Algicide

8. Probe Redox ERHS9. Temperature probe ETEPT10. Probe free chlorine ECL3S/1011. Probe chlorine ECL8/1012. Proximity sensor SEPR13. Probes holder PEF22

With RS485 + USB version The core of your communication system is MAX5 integrated. The software included realizes the connection beetween controller and PC by RS485 ora USB port.

With GSM + RS485 + USB versionGSM option is available for multiple MAX5 remote control.The communication software included allows to control one or more controllers even if they are installed on different plants. More over you canalways realizes the connection between the controller and PC by RS485 or a USB port. GSM option features SMS communication and SMS alarm.

With ETHERNET + RS485 + USBInternet: to log-in all you need is a PC, the remote management software and either local or remote network access. You can set the device to trigger email alerts. You can also access the Internet either by plugging a RS485 cable into your computer or via USB.

With WEBSERVER + HOSTING ServiceInternet: just a web browser for remote and reliable control of one or more MAX5 controllers. NO software or application needed. We host your controller’s interface! Otherwise you can always realize the connection between the controller and PC by RS485 or a USB port.

Hosting service operates with ETHERNET or GPRS / GSM option.

REMOTE CONTROL

Dosing Pump acid VMS MF 03 10 (10 l/h)Dosing Pump chlorine VMS MF 02 17 (17 l/h)

Controls pH, Redox, free Chlorine, total Chlorine, combined Chlorine and temperature

Dimensions: 800x800 mmPre-assembled panel. Available with customized / coloured background

Page 13: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

22 23

Accessories for controllers

EPHS

pH electrode for pressures up to 7bar/70°C (3.5bar/80°C).0.8m cable. Epoxy body.Minimum 100μS.

ERHS

ORP electrode for pressures up to7bar/70°C (3.5bar/80°C).0.8m cable. Epoxy body.Minimum 100μS.

ECL8

Total chlorine amperometric cell (organic and inorganic),from 0 to 2 mg/l ; from 0 to 20 mg/l, pH and temperature compensated.

ETEPT

Temperature probe PT100 (0°C÷100 °C, max 10bar). Suited for operations with LDxx, LDPHxx and Max5 series instruments.

ECL6 - ECL12

Free chlorine / bromine amperometric cell (organic and inorganic), from 0 to 10 mg/l.Flow switch and flow adjustment.Electrodes holder for pH, Redox and temperature.With proximity switch mod. SEPR. 6x8 fittings.

BUFFER SOLUTIONS

Buffer solutions for probes calibration.

ECL3S/10

Free chlorine amperometric cell (organic and inorganic),from 0 to 10 mg/l, pH and temperature compensated.

PEF1

Off-line electrode holder for ECL1/2/3/8/9/10/11 and pH,Redox and temperature, with flow switch and regulation.With proximity switch mod. SEPR. 6X8 fittings.

NFIL CA

Activated 5” filter with carbonfilter cartridge. 6x8 fittings.

NFIL

Filter with cartridge. Washable.PET (60 μ). 6x8 fittings.

PELC

PVDF in-line electrode holder for pH / Redox electrodeswith 1/2” or 3/4” thread.For saddle connection.

PEL

PVDF in-line electrode holder for pH / Redox electrodeswith 1/2” or 3/4” thread.For “T” connection.

EVLA

Electrovalve for dry feeder. 1/2” fitting.

PEF22

Holder for Chlorine, pH, Redox, free Chlorine, total Chlorine and temperature probes. Provided type SEPR flow controller. Suited for operations with MAX5 device.

NPED4

Off-line electrode holder for EPH and ERH electrodes. Epoxy Ø12 casing. Max temperature 50° C, max pressure 5bar with flow sensor, N.O. switch, 6x8 fittings.

Page 14: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

24

Accessories for pumps

LINR

1/2” injection lance for dosing sodium hypochlorite in hard water. Self cleaning. Viton® o-ring. PVC body.

MF MULTIFUNCTIONS VALVE

Multifunction valve (pressure, safety, antisyphon and bleed) 1/2” connectionsfor different hoses diameters. Viton® or EPDM o-ring.PVDF body.

PVDFINJECTIONVALVE

LEVEL PROBE WITH FOOT FILTER

CHEMICAL TANKS& SAFETY BUNDS

Polyethylene, anti-UV for chemicals. Complete chemicaltanks with safety bunds, metering pump and mixer.

MIXV/8

High speed mixer1400 RPM.AISI shaft-PVC coated,different lengths available(630-730-830-930 mm).Marine impeller,diameter 70mm.

MIX/8

Low speed mixer70/200 RPM.AISI shaft-PVC coated,different lengths available(630-730-830-930 mm).3-blade impeller,diameter 150mm.

MIX/MAN

Manual mixer.PVC shaft, differentlengths available(500-600 and 700-800 mm).Impeller diameter 130 mm.

LASP

Suction lanceswith level control,for tanks up to1000 liters.

LASP

Suction lanceswith level control,for tanks up to25 liters.

Page 15: pag 1 a4 - Προϊόνταchemofluid.gr/PDF-FILES/EMEC/Catalogo piscina_Inglese_31-01-2011.pdf · ISO 9001:2008 OHSAS 18001:2007 ... *Not available on mod. ... time alarm, chart

26

EMEC S.r.l.Via Donatori di Sangue, 1

02100 Vazia (RI) - Italia

T +39 0746 22841T +39 0746 1725114

F +39 0746 22842

[email protected]

Mar

ketin

g D

ept.

O2/

2011