Page 1 Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002 Envisat Validation Workshop Atmospheric Chemistry Validation Team Ground-Based Measurements and Campaign Database Subgroup Comparison of scientific SCIAMACHY products with ground- based measurements Klaus Bramstedt [email protected] bremen.de

Upload: christine-webb

Post on 02-Jan-2016

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Envisat Validation Workshop

Atmospheric Chemistry Validation Team

Ground-Based Measurements and Campaign Database Subgroup

Comparison of scientific SCIAMACHY products with ground-

based measurementsKlaus Bramstedt [email protected]

Page 2Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Scientific productsNon-operational algorithms for determining atmospheric parameters

in the scientific community.

Use:

Verification

Products not available yet

New products

Feedback for operat. products

Limitations:

0-1 processing/calibration

availability of Level 1 products

"non-operational“

Only preliminary case studies

Examples: - NO2 col. - CH4/CO col. - Ozone profile (limb) – PMC detection

Page 3Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Scientific NO2 columns DOAS (ife, University of Bremen, A. Richter)

Pacific radiance used as reference spectrum in DOAS fit

Compared with: Groundb.

DOAS Ny Alesund Bremen Nairobi(AO 331, A. Richter)

Page 4Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 5Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 6Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 7Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Comparison of CH4 and CO

WFM-DOAS (M. Buchwitz, IUP/ife Bremen) Reference spectra are derivatives of the radiance, fit

parameter is VCD Additional „Calibration Correction Function“ fitted

Iterat. maxim. likelihood method (H. Schrijver,SRON) Modelled spectrum is fitted to the measured spectrum.

Compared with: FTIR

Ny-Alesund (AO 331, A. Schulz) Kiruna (AO 191, T. Blumenstock)

Page 8Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 9Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 10Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 11Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 12Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 13Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 14Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Comparison of O3 profiles from limb

Limb ozone profiles (C. von Savigny, IUP/ife Bremen) Normalized, paired limb radiances are analysed with an

optimal estimation approach (OSIRIS)

Compared with: Ozone sondes from:

Ny-Alesund (AO 331, P. von der Gathen) Neumayer (Antarctica) (AO 331, P. von der Gathen) Hohenpeißenberg (AO 158, W. Steinbrecht)

Page 15Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Ny-Alesund 07.08.02Ny-Alesund 24.07.02

Page 16Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Neumayer 03.11.02Neumayer 10.10.02

Page 17Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Hohenpeißenberg 22.11.02Hohenpeißenberg 06.11.02

Page 18Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

Page 19Envisat Validation Workshop, ACVT-GBMCD, SCIAMACHY scient. prod. 12/12/2002

SummaryPreliminary Comparisons: CH4/CO columns: 2 algorithms available

up to 50% dev. (same order of magnitude!!) Ozone Limb profiles: Altitude shift (pointing problem?) NO2 columns: reliable relative and absolute values Antarctic ozone hole identified! PMCs can be detected in limb

All scientific retrievals and their validation suffer from O-1 processing problems (calibration and availability), but:

It´s in there!