Refrigeration Compressors, Chillers, Condensers Motors Electrical Heating Components Indoor Air Quality Thermostats Oils & Chemicals Accessories, Supplies & Commodities Tools & Instruments Refrigeration K-175 EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description Refrigeration, Low Temp. & Commerc i a l Installat ions Air Condit ioning Fie l d Replacement & Field Installat i ons R-12/R-134a R- 22 R-404A/R-502/R-507A R-12/ R-134a R-22/R- 407C/R-410A + STAS 485 T 8 10 8 8 10 STAS 487 T 10 13 10 10 12 1/2 STAS 489 T 10 15 10 10 15 STAS 4 8 11T 13 20 13 13 20 STAS 967 T 20 25 15 20 25 STAS 969 T 25 30 20 25 30 STAS 96 11T 30 35 25 30 35 STAS 96 13T 35 4 0 30 35 4 0 STAS-9625S-V 40 4 5 35 40 4 5 STAS 1 44 9T 30 4 0 30 30 4 0 STAS 144 11T 40 50 35 40 50 STAS 144 13T 45 55 4 0 45 55 STAS 144 17T 60 50 4 5 50 60 STAS 19211T 50 70 4 5 50 70 STAS 19213T 60 80 55 60 80 STAS 19217T 65 85 60 65 85 ADKS 30013T 50 65 4 5 50 65 ADKS 30017T 60 80 50 60 80 ADKS 4 0017T 65 85 55 65 85 ADKS 4 0021T 75 100 65 75 100 * For kW, mult iply tons by 3 . 5 + Consult product catalog pages for R-410A suitability.

Upload: lekhuong

Post on 26-Mar-2018

224 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-175

EMERSON CLIMATE TECHNOLOGIES-System ProtectorsRecommended System TonnageTake-Apart Liquid Line Filter Driers in Tons*

DescriptionRefrigeration, Low Temp. &

Commercial Installations

Air Conditioning

Field Replacement & Field Installations

R-12/R-134a R-22 R-404A/R-502/R-507A R-12/R-134a R-22/R-407C/R-410A+

STAS 485T 8 10 8 8 10 STAS 487T 10 13 10 10 12 1/2 STAS 489T 10 15 10 10 15

STAS 4811T 13 20 13 13 20 STAS 967T 20 25 15 20 25 STAS 969T 25 30 20 25 30

STAS 9611T 30 35 25 30 35 STAS 9613T 35 40 30 35 40

STAS-9625S-V 40 45 35 40 45 STAS 1449T 30 40 30 30 40

STAS 14411T 40 50 35 40 50 STAS 14413T 45 55 40 45 55 STAS 14417T 60 50 45 50 60 STAS 19211T 50 70 45 50 70 STAS 19213T 60 80 55 60 80 STAS 19217T 65 85 60 65 85 ADKS 30013T 50 65 45 50 65 ADKS 30017T 60 80 50 60 80 ADKS 40017T 65 85 55 65 85 ADKS 40021T 75 100 65 75 100

* For kW, multiply tons by 3.5 + Consult product catalog pages for R-410A suitability.

Sec#10d Refridge 46pages 2011_Fridge 12/9/2010 4:54 PM Page 45

Page 2: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-176

EMERSON CLIMATE TECHNOLOGIES-System ProtectorsRecommended System TonnageHermetic Liquid Line Filter Driers (EK, ADK, BFK, BOK)(Recommended Capacities at 2 psi drop (See catalog page showing ARI data for capacity at 1 psi drop.)

Refrigeration Low Temp. & Commercial Installations

Air Conditioning Field Replacement & Field Installations

DescriptionR-12/R-134a R-22 R-404A/R-502/R-507 R-12/R-134a R-22/R-407C/R-410A

032 032S 033

033S

1/2 1/2

052 052S

3/4 3/4

1/2 1 1-1/2

053 053S

1-1/2 2 1-1/2 3 4

082 082S

1 3/4 1-1/2 2

0825S 1

2 1 3 4083

083S 3 4 5

084 084S

24

25 7-1/2

162 162S

1-1/2 2 1 1-1/2 2

1625S 2 3 2 3 4163

163S 4 5

164 164S

55 10

165 165S

3

7-1/2 7-1/2 12

303 303S

5

3

4 6

304 304S

47-1/2 4 7-1/2 10

305 305S

10 15

307S 10

18 24309S

7-1/2

15

5

20 26413 4 5 5414

414S 4 5

5 7-1/2 12

415 415S

7-1/2 7-1/2 12 18

417S 107-1/2

18 25419S

1012 10 20 27

757S 20 25 15 22 30759S 22 30 20 25 34

Sec#10d Refridge 46pages 2011_Fridge 12/9/2010 4:54 PM Page 46

Page 3: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-177

EMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter DrierThe EK Liquid Line Filter Drier is a premium compacted bead Filter Drier with a fine 20 micron fine outlet pad for maximum filtration. The EK is a premium universal replacement liquid line Filter Drier for CFC, HCFC and HFC refrigerants including R-12, R-134a, R-22, R-404A, R-407C, R-410A, R-500, R-502, and R-507.

Features • Filtration first for more effective use of surface area of desiccant • High moisture and acid removal capacity • Solid copper connections • Corrosion resistant epoxy powder paint finish • Copeland® brand products approved for POE Oils • Shock resistant steel shell construction

Specifications • Desiccant blend - optimized for high water capacity and acid

capacity • Filtration: 20 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124

Nomenclature example: EK-083S EK 08 3 S

Drier Series

Unit Size (in cu. in.)

Connection Size

(in 1/8”)

S = ODF connections

(omit for SAE)

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 1

Page 4: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-178

EMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter DrierOrdering Information

Dimensions (in)PCN A B D E F Weight

(lbs)Description

060009 4.38 - - 2.56 1.63 0.50 EK 032060012 3.88 3.13 0.38 2.56 1.63 0.50 EK 032S060011 3.50 - - 2.56 1.63 0.50 EK 032FM060010 3.50 - - 2.56 1.63 0.50 EK 032MF060013 4.69 - - 2.56 1.63 0.50 EK 033060014 4.06 3.19 0.44 2.56 1.63 0.50 EK 033S047601 4.81 - - 3.00 2.63 0.88 EK 052057013 4.50 - - 3.00 2.63 0.88 EK 052MF063978 3.57 0.32 2.64 3.02 2.63 0.88 EK 0525S047602 4.44 3.69 0.38 3.00 2.63 0.88 EK 052S047603 5.13 - - 3.00 2.63 0.88 EK 053047604 4.50 3.63 0.44 3.00 2.63 0.88 EK 053S047605 5.63 - - 3.81 2.63 1.25 EK 082047606 5.25 4.50 0.38 3.81 2.63 1.25 EK 082S049551 5.38 4.38 0.50 3.81 2.63 1.25 EK 0825S056906 5.94 - - 3.81 2.63 1.25 EK 083MF047607 5.94 - - 3.81 2.63 1.25 EK 083047608 5.31 4.44 0.44 3.81 2.63 1.25 EK 083S047609 6.19 - - 3.81 2.63 1.25 EK 084047610 5.38 4.38 0.50 3.81 2.63 1.25 EK 084S047611 6.56 - - 4.75 2.63 1.25 EK162047612 6.19 5.44 0.38 4.75 2.63 1.25 EK 162S056045 5.94 5.31 0.31 4.75 2.63 1.25 EK 1625S047613 6.88 - - 4.75 2.63 1.25 EK 163047614 6.25 5.44 0.44 4.75 2.63 1.25 EK 163S047615 7.06 - - 4.75 2.63 1.25 EK 164047616 6.31 5.31 0.50 4.75 2.63 1.25 EK 164S047617 7.50 - - 4.75 2.63 1.25 EK 165047618 6.56 5.31 0.63 4.75 2.63 1.25 EK 165S047619 7.50 5.63 0.75 4.75 2.63 1.25 EK 167S048210 9.63 - - 7.50 3.06 3.75 EK 303048211 9.00 8.13 0.44 7.50 3.06 3.75 EK 303S048212 9.88 - - 7.50 3.06 3.75 EK 304048213 9.13 8.13 0.50 7.50 3.06 3.75 EK 304S048214 10.31 - - 7.50 3.06 3.75 EK 305048215 9.31 8.06 0.63 7.50 3.06 3.75 EK 305S048216 9.69 8.44 0.63 7.50 3.06 3.75 EK 306S048217 9.88 8.38 0.75 7.50 3.06 3.75 EK 307S048218 10.25 8.44 0.94 7.50 3.06 3.75 EK 309S048219 9.75 - - 7.63 3.69 4.75 EK 413048220 10.00 - - 7.63 3.69 4.75 EK 414048221 9.25 8.25 0.50 7.63 3.69 4.75 EK 414S048222 10.44 - - 7.63 3.69 4.75 EK 415048223 9.44 8.19 0.63 7.63 3.69 4.75 EK 415S048224 10.00 8.50 0.75 7.63 3.69 4.75 EK 417S048225 10.94 8.50 0.75 7.63 3.69 4.75 EK 419S048228 15.44 13.94 0.75 13.06 3.69 7.50 EK 757S048229 15.75 13.88 0.94 13.06 3.69 7.50 EK 759S

1 Does not include weld bead

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 2

Page 5: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-179

EMERSON CLIMATE TECHNOLOGIES-System Protectors EK Contractor’s Choice Filter DrierThe EK Contractor’s Choice filter drier is designed for foodservice and residential air conditioning applications.

Features • Extended solid copper connections • Dual access valves for faster and easier system diagnosis • Incorporates all the internal features of the premium EK

Specifications • Desiccant blend – optimized for high water capacity and acid capacity • Filtration: 20 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124 Ordering Information

PCN Description063908 EK 032S VV065966 EK 052S VV065963 EK 053S VV065964 EK 083S VV065965 EK 163S VV

EMERSON CLIMATE TECHNOLOGIES-System Protectors EK Cap Tube Filter DrierThe EK Cap Tube filter drier is designed for foodservice refrigera- tion systems.

Features • Schrader valve on the inlet side acts as a maintenance

and charging port • Outlet is designed to accept capillary tubing without the

need for crimping • Extended solid copper 1/4 ODF connection inlet by cap

tube • Incorporates all the internal features of the premium EK Specifications • Desiccant blend - optimized for high water capacity and

acid capacity • Filtration: 20 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124 Ordering Information

PCN Description063208 EK 032 SV CAP (3 cubic inch)065846 EK 052 SV CAP (5 cubic inch)

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 3

Page 6: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-180

EMERSON CLIMATE TECHNOLOGIES-System Protectors EK Filter DriersCapacity Tables

Water Capacity2 Drops of Water3Flow Capacity Tons @ 1 psi P1.4

(For kW, multiply tons by 3.5 ) R-12 R-134a R-22 R-407C R-410A R-404A/507 R-502 Description Connections

Inlet/Outlet R-12 R-

134aR-22/R-

410A R-407

CR-04A/R-507 75°F 125°

F 75°F 125°F 75°F 125°

F 75°F 125°F 75°F 125°

F 75°F 125°F 75°F 125°

FEK 03 2 FM 1/4 Fem/1/4 Male SAE 1.6 2.0 2.2 2.1 1.4 EK 03 2 MF 1/4 Male/1/4 Fem SAE 1.6 2.0 2.2 2.1 1.4

EK 03 2 1/4 SAE 1.6 2.0 2.2 2.1 1.4 EK 03 2 S 1/4 ODF 2.2 2.7 2.9 2.9 2.0 EK 032 SV 1/4 ODF 2.2 2.7 2.9 2.9 2.0

EK 03 3 3/8 SAE 2.5 3.0 3.3 3.2 2.2 EK 03 3 S 3/8 ODF 2.5 3.0 3.3 3.2 2.2

47 41 40 37 40 33 33 25 21 19 38 37 42 37

EK 05 2 FM 1/4 Fem/1/4 Male SAE 1.7 2.1 2.3 2.2 1.5 EK 05 2 MF 1/4 Male/1/4 Fem SAE 1.7 2.1 2.3 2.2 1.5

EK 05 2 1/4 SAE 1.7 2.1 2.3 2.2 1.5 EK 05 2 S 1/4 ODF 2.7 3.3 3.6 3.5 2.4

EK 05 3 MF 3/8 Male/3/8 Fem SAE 2.9 3.5 3.8 3.7 2.5 EK 05 3 3/8 SAE 2.9 3.5 3.8 3.7 2.5

EK 05 3 S 3/8 ODF 3.6 4.4 4.8 4.7 3.2

133 119 116 106 114 97 95 75 64 58 109 106 120 107

EK 08 2 FM 1/4 Fem/1/4 Male SAE 1.9 2.3 2.5 2.4 1.7 EK 08 2 MF 1/4 Male/1/4 Fem SAE 1.9 2.3 2.5 2.4 1.7

EK 08 2 1/4 SAE 1.9 2.3 2.5 2.4 1.7 EK 08 2 S 1/4 ODF 2.5 3.1 3.4 3.3 2.2

EK 08 25 S 5/16 ODF 2.9 3.5 3.8 3.7 2.5 EK 08 3 MF 3/8 Male/3/8 Fem SAE 3.3 4.0 4.3 4.3 2.9 EK 08 3 3/8 SAE 3.3 4.0 4.3 4.3 2.9

EK 08 3 S 3/8 ODF 3.7 4.5 4.9 4.8 3.3 EK 08 4 1/2 SAE 5.5 6.7 7.3 7.1 4.9

EK 08 4 S 1/2 ODF 5.8 7.1 7.7 7.5 5.1

274 240 237 218 235 200 195 155 159 118 224 217 245 217

EK 16 2 MF 1/4 Male/1/4 Fem SAE 1.9 2.3 2.5 2.4 1.7 EK 16 2 1/4 SAE 1.9 2.3 2.5 2.4 1.7

EK 16 2 S 1/4 ODF 2.5 3.1 3.4 3.3 2.2 EK 16 25 S 5/16 ODF 2.5 3.1 3.4 3.3 2.2

EK 16 3 3/8 SAE 3.2 3.9 4.2 4.1 2.8 EK 16 3 S 3/8 ODF 3.6 4.4 4.8 4.7 3.2 EK 16 4 S 1/2 ODF 7.0 8.5 9.2 9.0 6.2 EK 16 5 5/8 SAE 8.0 9.7 10.5 10.3 7.0

EK 16 5 S 5/8 ODF 8.3 10.1 10.9 10.7 7.3 EK 16 7 S 7/8 ODF 12.7 15.5 16.8 16.5 11.2

347 301 371 341 368 313 305 240 206 186 350 340 306 272

EK 30 3 3/8 SAE 3.5 4.3 4.7 4.6 3.1 EK 30 3 S 3/8 ODF 5.2 6.3 6.8 6.7 4.6 EK 30 4 1/2 SAE 6.6 8.1 8.8 8.6 5.9

EK 30 4 S 1/2 ODF 8.2 10.0 10.8 10.6 7.2 EK 30 5 5/8 SAE 8.7 10.6 11.5 11.3 7.7

EK 30 6 S 3/4 ODF 12.1 14.8 16.0 15.7 10.7 EK 30 7 S 7/8 ODF 13.8 16.8 18.2 17.9 12.2 EK 30 9 S 1 1/8 ODF 16.1 19.6 21.2 20.8 14.2

601 526 664 611 657 561 548 434 515 355 627 608 536 477

EK 41 3 3/8 SAE 3.5 4.3 4.7 4.6 3.1 EK 41 4 1/2 SAE 8.5 10.4 11.3 11.1 7.5

EK 41 4 S 1/2 ODF 8.9 10.8 11.7 11.5 7.8 EK 41 5 5/8 SAE 9.8 12.0 13.0 12.8 8.7

EK 41 7 S 7/8 ODF 16.6 20.3 22.0 21.6 14.7 EK 41 9 S 1 1/8 ODF 22.7 27.7 30.0 29.4 20.1

1104 971 938 854 919 785 765 607 715 465 876 850 991 884

EK 75 7 S 7/8 ODF 18.2 22.2 24.1 23.6 16.1 EK 75 9 S 1 1/8 ODF 26.8 32.7 35.4 34.8 23.7

2368 2159 2159 2019 2159 1880 1810 1460 1460 1111 2019 2019 2229 2019

1All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature

5°F saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R-407C 4.0 lbs./min./ton for R-404A/507 and R-12 2.7 lbs./min./ton for R-410A

2 Water Capacities are based on:Equilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404- A/507, R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

320 drops of water = 1 gram = 1 cc 4For 2 PSI P, Multiply values by 1.4

Liquid Refrigerant Holding Capacity-OuncesUnit Size

R-12 R-134a R-22 R-407C R-410A R-404A/R-507 R-502 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F

03 2.9 2.6 2.6 2.3 2.6 2.3 2.5 2.1 2.3 1.9 2.3 1.9 2.7 2.3 05 6.5 5.9 6.0 5.4 5.9 5.3 5.6 4.9 5.3 4.4 5.2 4.4 6.0 5.3 08 8.3 7.6 7.6 6.9 7.5 6.8 7.2 6.3 6.7 5.7 6.6 5.6 7.7 6.8 16 10.2 9.4 9.4 8.6 9.3 8.4 8.9 7.8 8.3 7.0 8.2 6.9 9.5 8.4 30 28.7 26.3 26.4 23.9 26.1 23.5 24.9 21.9 23.3 19.6 22.9 19.4 26.7 23.4 41 40.0 36.4 36.9 33.1 36.4 32.5 34.7 30.3 32.5 27.2 31.9 26.8 37.2 32.4 75 72.4 66.3 66.7 60.3 65.8 59.2 62.8 55.2 58.7 49.5 57.7 48.9 67.2 59.0

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 4

Page 7: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-181

EMERSON CLIMATE TECHNOLOGIES-System Protectors ADK Core Style Liquid Line Filter DrierThe ADK is a solid core liquid line Filter Drier ideal for use with CFC, HCFC, and HFC refrigerants.

Features • Solid copper connections • High moisture and acid removal capacity • Corrosion resistant epoxy powder paint finish • Copeland® products approved for POE oils

Specifications • Desiccant Blend: optimized for high water capacity and acid capacity • Filtration: 40 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124Nomenclature example: ADK 083S

ADK 08 3 S

Series Unit Size (in cu. in.)

Connection Size

(in 1/8”)

S = ODF connections

(omit for SAE)

Ordering InformationDimensions (in)

PCN ConnectionSize

A B D E Weight(lbs)

Description

059874 1/4 SAE 4.38 2.56 1.75 0.50 ADK-032052451 1/4 ODF 3.88 3.13 0.38 2.56 1.75 0.50 ADK-032S023157 3/8 SAE 4.69 2.56 1.75 0.50 ADK-033053172 3/8 ODF 4.06 3.25 0.44 2.56 1.75 0.50 ADK-033S060125 1/4 SAE 4.88 3.00 2.63 1.00 ADK-052060126 1/4 ODF 4.44 3.69 0.38 3.00 2.63 1.00 ADK-052S060127 3/8 SAE 5.13 3.00 2.63 1.00 ADK-053060128 3/8 ODF 4.50 3.69 0.44 3.00 2.63 1.00 ADK-053S060129 1/4 SAE 5.63 3.81 2.63 1.25 ADK-082060130 1/4 ODF 5.00 4.31 0.38 3.81 2.63 1.25 ADK-082S060131 3/8 SAE 5.94 3.81 2.63 1.25 ADK-083060132 3/8 ODF 5.38 4.06 0.63 3.81 2.63 1.25 ADK-083S060133 1/2 SAE 6.19 3.81 2.63 1.25 ADK-084060134 1/2 ODF 5.38 4.06 0.75 3.81 2.63 1.25 ADK-084S059838 1/4 ODF 6.94 5.25 0.25 4.75 2.63 1.75 ADK-162S059820 1/4 SAE 6.56 4.75 2.63 1.75 ADK-162059839 3/8 SAE 6.75 4.75 2.63 1.75 ADK-163060795 3/8 ODF 6.25 5.00 0.63 4.75 2.63 1.75 ADK-163S059840 1/2 SAE 7.13 4.75 2.63 1.75 ADK-164059841 1/2 ODF 6.38 5.00 0.75 4.75 2.63 1.75 ADK-164S059842 5/8 SAE 7.56 4.75 2.63 1.75 ADK-165059843 5/8 ODF 6.56 5.13 0.63 4.75 2.63 1.75 ADK-165S060172 3/8 SAE 9.63 7.50 3.13 3.50 ADK-303058507 5/8 ODF 8.94 8.13 0.44 7.50 3.13 3.50 ADK-303S060173 1/2 SAE 9.81 7.50 3.13 3.50 ADK-304060176 1/2 ODF 9.06 8.06 0.50 7.50 3.13 3.50 ADK-304S060174 5/8 SAE 10.31 7.50 3.13 3.50 ADK-305060177 5/8 ODF 9.25 8.00 0.63 7.50 3.13 3.50 ADK-305S060178 7/8 ODF 9.88 8.38 0.75 7.50 3.13 3.50 ADK-307S060179 1-1/8 ODF 10.19 8.38 0.94 7.50 3.13 3.50 ADK-309S060182 3/8 SAE 9.75 7.63 3.69 4.75 ADK-413060183 1/2 SAE 10.00 7.63 3.69 4.75 ADK-414060185 1/2 ODF 9.19 8.19 0.50 7.63 3.69 4.75 ADK-414S060184 5/8 SAE 10.44 7.63 3.69 4.75 ADK-415060186 5/8 ODF 9.44 8.19 0.63 7.63 3.69 4.75 ADK-415S060187 7/8 ODF 10.00 8.50 0.75 7.63 3.69 4.75 ADK-417S060188 1-1/8 ODF 10.38 8.50 0.94 7.63 3.69 4.75 ADK-419S060190 7/8 ODF 15.50 14.94 0.75 13.13 3.69 7.75 ADK-757S060191 1-1/8 ODF 15.88 14.17 0.94 13.13 3.69 7.75 ADK-759S

1 Does not include weld bead

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 5

Page 8: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-182

EMERSON CLIMATE TECHNOLOGIES-System Protectors ADK Filter DriersCapacity Tables

Water Capacity2 Drops of Water3Flow Capacity Tons @ 1 psi P1.4

(For kW, multiply tons by 3.5 ) R-12 R-134a R-22 R-407C R-410A R-404A/507 R-502 Description Connections

R-12 R-134a R-22 R-410A R-407C R404A/507 125°F 75°F 125°

F 75°F 125°F 75°F 125°

F 75°F 125°F 75°F 125°

F 75°F 125°F

ADK 032 1/4 SAE 1.6 1.9 2.1 2.1 2.0 1.4 ADK 032S 1/4 ODF 1.9 2.3 2.5 2.5 2.4 1.7 ADK 033 3/8 SAE 2.2 2.7 2.9 2.9 2.9 2.0

ADK 033S 3/8 ODF 2.5 3.0 3.3 3.3 3.2 2.2

70 74 68 69 63 57 46 47 36 76 72 71 63

ADK 052 1/4 SAE 1.6 2.0 2.2 2.2 2.1 1.4 ADK 052S 1/4 ODF 2.4 2.9 3.1 3.1 3.1 2.1 ADK 053 3/8 SAE 3.0 3.7 4.0 4.0 3.9 2.7 ADK 53S 3/8 ODF 3.7 4.5 4.9 4.9 4.8 3.3

185 195 180 180 130 150 120 125 95 200 190 185 165

ADK 082 1/4 SAE 1.6 2.0 2.2 2.2 2.1 1.4 ADK 082S 1/4 ODF 2.5 3.1 3.4 3.4 3.3 2.2 ADK 083 3/8 SAE 3.5 4.3 4.7 4.7 4.6 3.1

ADK 083S 3/8 ODF 3.4 4.2 4.6 4.6 4.5 3.0 ADK 084 1/2 SAE 5.5 6.7 7.3 7.3 7.1 4.9

ADK 084S 1/2 ODF 5.7 7.0 7.6 7.6 7.4 5.1

250 265 245 250 225 205 165 170 130 275 260 255 230

ADK 162 1/4 SAE 1.6 2.0 2.2 2.2 2.1 1.4 ADK 163 1/4 SAE 3.6 4.4 4.8 4.8 4.7 3.2

ADK 163S 3/8 ODF 4.0 4.9 5.3 5.3 5.2 3.6 ADK 164 1/2 SAE 6.8 8.3 9.0 9.0 8.8 6.0

ADK 164S 1/2 ODF 7.1 8.6 9.3 9.3 9.1 6.2 ADK 165 5/8 SAE 9.7 11.8 12.8 12.8 12.5 8.6

ADK 165S 5/8 ODF 10.7 13.1 14.2 14.2 13.9 9.5 ADK 167S 7/8 ODF 13.1 16.0 17.3 17.3 17.0 11.8

365 390 360 265 330 300 240 250 190 400 380 375 335

ADK 303 3/8 SAE 3.9 4.7 5.1 5.1 5.0 3.4 ADK 304 1/2 SAE 7.1 8.6 9.3 9.3 9.1 6.2

ADK 304S 1/2 ODF 7.2 8.8 9.5 9.5 9.4 6.4 ADK 305 5/8 SAE 11.3 13.8 15.0 15.0 14.7 10.0

ADK 305S 4/8 ODF 11.9 14.5 15.7 15.7 15.4 10.5 ADK 306S 3/4 ODF 13.0 15.8 17.1 17.1 16.8 11.5 ADK 307S 7/8 ODF 14.3 17.4 18.9 18.9 18.5 12.6 ADK 309S 1 1/8 ODF 20.4 24.9 27.0 27.0 26.5 18.0

820 865 800 810 740 675 540 555 420 895 845 835 745

ADK 413 3/8 SAE 3.9 4.7 5.1 5.1 5.0 3.4 ADK 414 1/2 SAE 8.0 9.8 10.6 10.6 10.4 7.1

ADK 414S 1/2 ODF 8.8 10.7 11.6 11.6 11.4 7.8 ADK 415 5/8 SAE 12.8 15.6 16.9 16.9 16.6 11.3

ADK 415S 5/8 ODF 13.5 16.5 17.9 17.9 17.5 12.0 ADK 417S 7/8 ODF 16.6 20.3 22.0 22.0 21.7 14.7 ADK 419S 1 1/8 ODF 20.7 25.2 27.3 27.3 26.8 18.3

1120 1210 1100 1140 1010 945 740 780 580 1260 1156 1170 1020

ADK 757S 7/8 ODF 28.0 34.2 37.1 37.1 36.3 24.8 ADK 759S 1 1/8 ODF 30.6 37.3 40.4 40.4 39.6 27.0

1985 2100 1940 1956 1800 1635 1310 1350 1030 2170 2050 2025 1800

1All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature

5°F saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R- 407C 4.0 lbs./min./ton for R-404A/507 and R-12 2.7 lbs./min./ton for R-410A

2 Water Capacities are based on: Equilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404- A/507, R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

320 drops of water = 1 gram = 1 cc

4For 2 PSI P, Multiply values by 1.4

Liquid Refrigerant Holding Capacity-OuncesR-12 R-134a R-22 R-407C R-410A R-404A/R-507 R-502

Unit Size 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 03 2.4 2.2 2.2 2.0 2.2 2.0 2.1 1.9 2.0 1.7 1.9 1.7 2.7 2.3 05 5.9 6.0 5.5 5.5 5.4 5.4 5.2 5.0 4.8 4.5 4.7 4.5 6.0 5.3 08 8.0 7.4 7.4 6.7 7.3 6.6 7.0 6.2 6.5 5.5 6.4 5.5 7.7 6.8 16 14.5 12.5 13.4 11.4 13.2 11.2 12.6 10.4 11.7 9.4 11.6 9.3 9.5 8.4 30 21.8 19.9 20.1 18.1 19.8 17.8 18.9 16.6 17.4 14.9 17.4 14.7 26.7 23.4 41 29.3 26.8 26.9 24.4 26.6 23.9 25.4 22.3 23.7 20.0 23.3 19.7 37.2 32.4 75 52.8 48.3 48.6 43.9 48.0 43.1 45.8 40.2 42.8 36.0 42.1 35.6 67.2 59.0

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 6

Page 9: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-183

EMERSON CLIMATE TECHNOLOGIES-System Protectors BFK Liquid Line Bi-Directional FilterDrierThe BFK is a solid core, bi-directional, liquid line Filter Drier for heat pump applications for use with CFC, HCFC, and HFC refrigerants.

Features • Available 5 to 30 cu. in. size • Internal check valves allow flow and filtration in either direction, eliminates

need for external check valves • High moisture and acid removal capacity • Corrosion resistant epoxy powder paint finish • Copeland® brand products approved for POE oils

Specifications • Desiccant Blend: optimized for high water capacity and acid capacity • Filtration: 40 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124

Nomenclature example: BFK 165S BFK 16 5 S

Series Unit Size (in cu. in.)

Connection Size

(in 1/8”)

S = ODF connections

(omit for SAE)

Ordering Information Dimensions (in)

PCN ConnectionSize

A B C D E Weight(lbs)

Description

062300 1/4 SAE 4.82 3.00 2.62 1.00 BFK-052062425 1/4 ODF 4.44 3.00 3.69 2.62 0.38 1.00 BFK-052S062254 3/8 SAE 5.13 3.00 2.62 1.00 BFK-053062255 3/8 ODF 4.48 3.00 3.67 2.62 0.40 1.00 BFK-053S058584 1/4 ODF 5.27 3.82 4.52 2.62 0.38 1.00 BFK-082S058597 5/16 ODF 5.02 3.82 4.38 2.62 0.32 1.00 BFK-0825S043321 3/8 SAE 5.94 3.82 2.62 1.00 BFK-083043323 3/8 ODF 5.29 3.82 4.48 2.62 0.40 1.00 BFK-083S043325 1/2 SAE 6.16 3.82 2.62 1.00 BFK-084043327 1/2 ODF 5.38 3.82 4.38 2.62 0.50 1.00 BFK-084S043728 5/8 SAE 6.62 3.82 2.62 1.00 BFK085043730 5/8 ODF 5.60 3.82 4.35 2.62 0.63 1.00 BFK-085S043330 3/8 SAE 6.74 4.61 3.15 2.00 BFK-163043333 3/8 ODF 6.08 4.61 5.28 3.15 0.40 2.00 BFK-163S043335 1/2 SAE 6.96 4.61 3.15 2.00 BFK-164043337 1/2 ODF 6.17 4.61 5.17 3.15 0.50 2.00 BFK-164S043732 5/8 SAE 7.41 4.61 3.15 2.00 BFK-165043734 5/8 ODF 6.39 4.61 5.14 3.15 0.63 2.00 BFK-165S058589 7/8 ODF 6.99 7.5 5.49 3.15 0.25 2.00 BFK-167S063076 3/8 SAE 9.63 7.5 5.49 3.15 2.00 BFK303063077 3/8 ODF 8.97 7.5 5.49 3.15 0.40 3.75 BFK-303S063078 1/2 SAE 9.84 7.5 5.49 3.15 3.75 BFK-304063079 1/2 ODF 9.02 7.5 5.49 3.15 0.50 3.75 BFK-304S063080 5/8 SAE 10.31 7.5 5.49 3.15 3.75 BFK-305063081 5/8 ODF 9.31 7.5 5.49 3.15 0.63 3.75 BFK-305S063082 3/4 SAE 10.61 7.5 5.49 3.15 3.75 BFK-306063083 3/4 ODF 9.72 7.5 5.49 3.15 3.75 BFK-306S063084 7/8 ODF 9.91 7.5 5.49 3.15 0.75 3.75 BFK-307S063451 1 1/8 ODF 10.22 7.5 5.49 3.15 0.91 3.75 BFK-309S

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 7

Page 10: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-184

EMERSON CLIMATE TECHNOLOGIES-System Protectors BFK Liquid Line Bi-Directional FilterDrier

Flow Capacity Tons @ 1 psi P 1, 4

(For kW, multiply tons by 3.5 ) Water Capacity2 Drops of Water3

R-22 R-407C R-410Description Connection R-22 R-410A R-407C

75°F 125°F 75°F C 125°F A 75°F A 125°F BFK-05 2 1/4 SAE 1.6 1.6 1.6

BFK-05 2S 1/4 ODF 2.2 2.2 2.2BFK-05 3 3/8 SAE 3.5 3.5 3.4

BFK-05 3S 3/8 ODF 4.0 4.0 3.9

73 66 58 42 39 35

BFK-08 3 3/8 SAE 4.5 4.5 4.4BFK-08 3S 3/8 ODF 5.1 5.1 5.0BFK-08 4 1/2 SAE 6.4 6.4 6.3

BFK-08 4S 1/2 ODF 6.7 6.7 6.6BFK-08 5 5/8 SAE 7.2 7.2 7.0

BFK-08 5S 5/8 ODF 8.1 8.1 7.9

159 144 106 79 85 75

BFK-16 3 3/8 SAE 4.6 4.6 4.5BFK-16 3S 3/8 ODF 5.2 5.2 5.1BFK-16 4 1/2 SAE 7.7 7.7 7.6

BFK-16 4S 1/2 ODF 8.1 8.1 7.9BFK-16 5 5/8 SAE 8.3 8.3 8.1

BFK-16 5S 5/8 ODF 8.7 8.7 8.5

323 294 237 179 178 160

BFK-30 3S 3/8 ODF 5.8 5.8 5.7BFK-30 4 1/2 SAE 7.6 7.6 7.5

BFK-30 4S 1/2 ODF 9.7 9.7 9.5BFK-30 5 5/8 SAE 10.3 10.3 10.1

BFK-30 5S 5/8 ODF 14.2 14.2 13.9 BFK-30 6S 3/4 ODF 16.0 16.0 15.7 BFK-30 7S 7/8 ODF 16.7 16.7 16.4 BFK-30 9S 1 1/8 ODF 18.0 18.0 17.5

585 532 452 345 415 293

1All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature

5°F saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R-407C 4.0 lbs./min./ton for R-404A/507 and R- 122.7 lbs./min./ton for R-410A

2 Water Capacities are based on: Equilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404- A/507, R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

320 drops of water = 1 gram = 1 cc 4For 2 PSI P, Multiply values by 1.4

Liquid Refrigerant Holding Capacity-OuncesR-22 R-407C R-410A

Unit Size 75°F 125°F 75°F 125°F 75°F 125°F 05 4.6 4.2 4.4 3.9 4.1 3.5

08 7.7 6.9 7.3 6.4 6.9 5.8

16 14.2 12.7 13.5 11.8 12.6 10.6 30 21.0 18.7 20.0 17.4 19.6 16.5

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 8

Page 11: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-185

EMERSON CLIMATE TECHNOLOGIES-System Protectors BOK-HH Liquid Line Burnout Filter DrierThe BOK-HH is a liquid line Filter Drier for burnout clean-up and wax removal. The BOK-HH incorporates an activated carbon blended solid core for the effective clean-up of systems following a severe burnout.

Features • Designed for maximum effectiveness in the clean-up of systems following

a severe burnout • Corrosion resistant epoxy powder paint finish • Activated carbon blend for soluble contaminant and wax removal • Solid copper connections

Specifications • Filtration: 40 microns • Maximum working pressure: 680 psig • UL/CUL fi le number: SA 3124

Nomenclature example: BOK 305S-HH BOK 30 5 S HH

Series Unit Size (in cu. in.)

Connection Size

(in 1/8”)

S = ODF connections

(omit for SAE)

Activated carbon Blend

Ordering InformationDimensions (in)

PCN ConnectionSize

A B D E Weight(lbs)

Description

060223 1/4 SAE 5.63 -- -- 3.94 2.94 1.00 BOK-082-HH064591 1/4 ODF 5.00 4.31 0.38 3.81 2.63 1.00 BOK-082S060224 3/8 SAE 5.94 -- -- 3.94 2.94 1.00 BOK-083-HH057995 3/8 ODF 5.38 4.06 0.63 3.81 2.63 1.00 BOK-083S060240 1/4 SAE 6.44 -- -- 3.94 2.94 1.00 BOK-162-HH064592 1/4 ODF 6.03 5.29 0.38 4.63 3.13 1.00 BOK-162S-HH060241 3/8 SAE 6.75 -- -- 3.94 2.94 1.00 BOK-163-HH060242 3/8 ODF 6.13 5.25 0.94 4.63 2.88 2.00 BOK-163S-HH060228 1/2 SAE 6.94 -- -- 4.63 2.88 2.00 BOK-164-HH060229 1/2 ODF 6.19 5.16 0.50 4.63 2.88 2.00 BOK-164S-HH060230 5/8 SAE 7.44 -- -- 4.63 2.88 2.00 BOK-165-HH060231 5/8 ODF 6.38 5.13 0.63 7.50 3.06 3.75 BOK-165S-HH060232 3/8 SAE 9.63 -- -- 7.50 3.06 3.75 BOK-303-HH060233 1/2 SAE 9.88 -- -- 7.50 3.06 3.75 BOK-304-HH060234 1/2 ODF 9.13 8.13 0.50 7.50 3.06 3.75 BOK-304S-HH060235 5/8 SAE 10.31 -- -- 7.50 3.06 3.75 BOK-305-HH060236 5/8 ODF 9.31 8.06 0.63 7.50 3.06 3.75 BOK-305S-HH060237 1/2 SAE 10.00 -- -- 7.63 3.69 4.75 BOK-414-HH060238 5/8 SAE 9.25 8.25 0.50 7.63 3.69 4.75 BOK-415-HH060239 7/8 ODF 10.44 -- -- 7.63 3.69 4.75 BOK-417S-HH064593 5/8 ODF 9.25 8.25 0.50 7.63 3.69 4.75 BOK-415S-HH

1 Does not include weld bead

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 9

Page 12: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-186

EMERSON CLIMATE TECHNOLOGIES-System Protectors BOK-HH Liquid Line Burnout Filter DrierWater Capacity2

Drops of Water3Flow Capacity Tons @ 1 psi P1.4

(For kW, multiply tons by 3.5 ) R-12 R-134a R-22 R-407C R-410A R-404A/507 R-502 Description Connections

R-12 R-134a R-22 R-410A R-407C R404A/507 75°F 125°F 75°F 125°F 75°F 125°F 75°F125°F 75°F 125°F 75°F 125°F 75°F 125°F

BOK 08 2-HH 1/4 SAE 1.2 1.5 1.6 1.6 1.6 1.1 180 118 BOK 082S 1/4 ODF - 3.1 3.4 3.4 3.3 2.2 - -

BOK 08 3-HH 3/8 SAE 3.2 3.9 4.2 4.2 4.1 2.8 180 118 BOK 083S 3/8 ODF - 4.2 4.6 4.6 4.5 3.0 - -

88 71 78 59 74 45 66 38 93 71 109 79

BOK 16 2-HH 1/4 SAE 1.2 1.5 1.6 1.6 1.6 1.1 BOK 16 3-HH 3/8 SAE 3.6 4.3 4.7 4.7 4.6 3.1

BOK 16 3S-HH 3/8 ODF 4.8 5.8 6.3 6.3 6.2 4.2 BOK 16 4-HH 1/4 SAE 7.0 8.6 9.3 9.3 9.1 6.2

BOK 16 4S-HH 1/4 ODF 8.4 10.2 11.1 11.1 10.9 7.4 BOK 16 5-HH 5/8 SAE 10.5 12.8 13.9 13.9 13.6 9.3

BOK 16 5S-HH 5/8 ODF 10.5 12.8 13.9 13.9 13.6 9.3

209 143 171 141 153 117 91 56 77 41 182 141 135 100

BOK 30 3-HH 3/8 SAE 3.6 4.3 4.7 4.7 4.6 3.1 BOK 30 4-HH 1/2 SAE 8.1 9.9 10.7 10.7 10.5 7.2

BOK 30 4S-HH 1/2 ODF 8.9 10.8 11.7 11.7 11.5 7.8 BOK 30 5-HH 5/8 SAE 11.1 13.5 14.6 14.6 14.3 9.8

BOK 30 5S-HH 5/8 ODF 12.0 14.6 15.8 15.8 15.5 10.6

552 367 300 245 267 204 234 146 160 94 318 247 342 249

BOK 41 4-HH 1/4 SAE 8.4 10.2 11.1 11.1 10.9 7.4 BOK 41 5-HH 5/8 SAE 13.4 16.3 17.7 17.7 17.4 11.8

BOK 41 5S-HH 5/8 ODF 13.4 16.3 17.7 17.7 21.1 14.4 BOK 41 7S-HH 7/8 ODF 16.3 19.8 21.5 21.5 21.1 14.4

623 410 427 344 379 282 256 155 220 125 454 342 380 274

1All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature

5°F saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R-407C 4.0 lbs./min./ton for R-404A/507 and R- 122.7 lbs./min./ton for R-410A

2 Water Capacities are based on: Equilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404- A/507, R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

320 drops of water = 1 gram = 1 cc

4For 2 PSI P, Multiply values by 1.4

Liquid Refrigerant Holding Capacity - OuncesR-12 R-134a R-22 R-407C R-410A R-404A/ R-507 R-502

Unit Size 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 08 7.3 6.6 6.7 6.0 6.6 5.9 6.3 5.5 5.9 4.9 5.8 4.9 6.7 5.9

16 13.9 12.7 12.8 11.5 12.6 11.3 12.0 10.5 11.2 9.4 11.1 9.3 12.9 11.3

30 21.8 19.9 20.1 18.1 19.8 17.8 18.9 16.6 11.7 14.9 17.4 14.7 20.2 17.7 41 29.3 26.8 26.9 24.4 26.6 23.9 25.4 22.3 23.7 20.0 23.3 19.7 27.2 23.8

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 10

Page 13: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-187

EMERSON CLIMATE TECHNOLOGIES-System Protectors ALF Liquid FilterThe ALF is a liquid line refrigerant filter for recovery, recycle and reclaim usage. The ALF is also used for protecting solenoid and expansion valve parts from debris.

Features • Filtering media that maximizes

removal of finer particles • Corrosion resistant epoxy powder

paint finish

Specifications • Filtration: 40 microns • Maximum working pressure: 680 psig • UL/CUL file number: SA 3124

Nomenclature example: ALF 033S ALF 03 3 S

Series Unit Size Connection Size Inlet (in 1/8”)

Connection Style S = ODF

Omit for SAE

Ordering Information Dimensions (in)

PCN Connection SizeInlet/Outlet

A C Description

058500 1/4 SAE 2.56 1.63 4.38 ALF-032056618 1/4 ODF 2.56 1.63 3.88 ALF-032S057193 1/4 SAE Male In 2.56 1.63 4.00 ALF-032MF057193 1/4 SAE Female

Out2.56 1.63 4.00 ALF-032MF

057140 3/8 ODF 2.56 1.63 4.00 ALF-033S056645 1/2 ODF 2.56 1.63 4.13 ALF-034S064777 1/4 SAE 3.00 2.63 4.88 ALF-052

1 Does not include weld bead

Recovery, Recycle and Reclaim Refrigerant Flow Capacity (lbs./min. liquid)

R-134A R-22/R-410A R-404A/R-5077.6 8.0 8.0

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 11

Page 14: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-188

EMERSON CLIMATE TECHNOLOGIES-System Protectors Spun Copper Liquid Line Filter DrierThe CU series is a high capacity spun copper solid core Filter Drier idea l for superior corrosion resistance in ocean going vessels and coastal appl ications.

Features • All copper construction for extreme corrosion resistance • 100% molecu lar sieve so lid core drier • For use with CFC, HCFC and HFC refrigerants

Nomenclature example: CU 163S Specifications • Maximum working pressure: 500 psig • Fil tration: 40 microns • UL/CUL file number: SA 7175

CU 16 3 S

Series Unit Size Connection Size (in 1/8”) ODF

Ordering Information and Capacity TablesPCN Connection R-12 R-134a R-22 R-407CR-404A/

R-507R-1275°F

R-12125°F

R-134a75°F

R-134a125°F

R-2275°F

R-22125°F

R-407C75°F

R-407C125°F

R-404A/R-507 75°F

R-404A/R-507 125°F

R-50275°F

R-502125°F

Description

064388 1/4 ODF 1.4 1.7 1.8 1.8 1.2 96 87 93 87 87 81 72 57 96 93 90 81 CU 03 2 S064389 3/8 ODF 2.1 2.6 2.8 2.7 1.9 96 87 93 87 87 81 72 57 96 93 90 81 CU 03 3 S064390 1/4 ODF 1.5 1.8 2.0 2.0 1.3 112 101 108 101 101 93 82 63 112 108 104 93 CU 05 2 S064391 3/8 ODF 2.1 2.6 2.8 2.7 1.9 112 101 108 101 101 93 82 63 112 108 104 93 CU 05 3 S064392 1/4 ODF 1.6 1.9 2.1 2.1 1.4 212 191 205 191 191 177 156 122 212 205 198 177 CU 08 2 S064393 3/8 ODF 2.9 3.5 3.8 3.7 2.5 212 191 205 191 191 177 156 122 212 205 198 177 CU 08 3 S064394 1/2 ODF 3.5 4.2 4.6 4.5 3.1 212 191 205 191 191 177 156 122 212 205 198 177 CU 08 4 S064395 3/8 ODF 3.3 4.0 4.3 4.2 2.9 287 257 277 257 257 237 207 158 287 277 267 237 CU 16 3 S064396 1/2 ODF 3.9 4.7 5.1 5.0 3.4 287 257 277 257 257 237 207 158 287 277 267 237 CU 16 4 S064397 5/8 ODF 4.4 5.4 5.8 5.7 3.9 287 257 277 257 257 237 207 158 287 277 267 237 CU 16 5 S1 All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature 5°F saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R-407C 4.0 lbs./min./ton for R-404A/507 and R-12 2.7 lbs./min./ton for R-410A

2 Water Capacities are based on: Equilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404-A/507, R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

3 20 drops of water = 1 gram = 1 cc 4 For 2 PSI P, Multiply va lues by 1.4

Dimensional Data (in)Overall Length (A) Lay-In Dimension (B) Diameter Description

3.94 3.25 1.63 CU 03 5.19 4.50 1.63 CU 05 6.06 5.38 2.00 CU 08 6.63 6.00 2.00 CU 16

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 12

Page 15: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-189

EMERSON CLIMATE TECHNOLOGIES-System Protectors STAS Steel Liquid and Suction FilterDrier

The STAS is a replaceable core Filter Drier for CFC, HCFC, and HFC refrigerants for use in large commercial air conditioning and refrigerant systems.

Features • Slotted cover/unique internal hardware for hassle-free instal lation • Fu ll flow fittings for low pressure drop • Corrosion resistant epoxy powder paint finish • Sturdy steel shells for long l ife • Solid copper connections • 100 mesh outlet screen

Nomenclature example: STAS 489T Specifications • Filtration (with core): 40 microns • Maximum working pressure: SV version = 500 psig T version = 680 psig

• UL/CUL file number: SA7175

STAS Models are shipped without filter or filter drier cores. See filter or filter drier cores for availability.

STAS 48 9 TSteel

Take-Apart Series

Unit Size (in cu . in.)

Connection Size (in 1/8”)

System Service T = Liquid Line Service

SV = Suction Line Service

Ordering InformationDimensions (in)

PCN ConnectionSize

DesiccantVolume (Cu. In.)

A B C D Description

053001 *5/8 ODF 1 48 9.94 6.00 3.78 0.63 STAS-485T053003 *7/8 ODF 1 48 9.69 6.25 3.75 0.78 STAS-487T053005 *1 1/8 ODF 1 48 9.75 6.31 3.84 0.94 STAS-489T053007 *1 3/8 ODF 1 48 9.84 6.44 3.97 0.94 STAS-4811T053043 1 5/8 ODF 1 48 9.88 6.02 4.03 1.13 STAS-4813S-V*053044 2 1/8 ODF 1 48 10.06 6.56 4.56 1.34 STAS-4817S-V*053045 2 5/8 ODF 1 48 10.44 7.03 4.75 1.04 STAS-4821S-V*053375 1 5/8 ODF 1 48 9.88 6.50 4.03 1.13 STAS-4813T053938 1 3/8 ODF 1 48 9.84 6.44 3.97 0.94 STAS-4811SV053010 *7/8 ODF 2 96 15.19 11.72 3.75 0.78 STAS-967T053012 *1 1/8 ODF 2 96 15.22 11.78 3.84 0.94 STAS-969T053014 *1 3/8 ODF 2 96 15.31 11.91 3.97 1.03 STAS-9611T053017 *1 5/8 ODF 2 96 15.38 11.97 4.03 1.13 STAS-9613T053018 *2 1/8 ODF 2 96 15.56 12.03 4.56 1.34 STAS-9617T053047 2 1/8 ODF 2 96 15.56 12.03 4.56 1.34 STAS-9617S-V*053048 2 5/8 ODF 2 96 15.94 12.50 4.75 1.50 STAS-9621S-V*059739 3 1/8 ODF 2 96 16.54 12.63 5.44 1.66 STAS-9625 SV053020 1 1/8 ODF 3 144 21.25 17.38 3.84 0.94 STAS-1449T053022 1 3/8 ODF 3 144 21.34 17.53 3.97 1.03 STAS-14411T053024 1 5/8 ODF 3 144 21.38 17.59 4.03 1.13 STAS-14413T053025 2 1/8 ODF 3 144 21.56 17.63 4.56 1.34 STAS-14417T053028 1 3/8 ODF 4 192 26.91 23.00 3.97 1.03 STAS-19211T053030 1 5/8 ODF 4 192 26.94 23.17 4.03 1.13 STAS-19213T053031 2 1/8 ODF 4 192 27.13 23.13 4.56 1.34 STAS-19217T056213 7/8 X 5/8 4 192 26.50 6.00 3.69 0.78/0.63 STAS-1927/5T

* “SV” style include stainless steel bolts and access valve. NOTE: “T” style can be used for suction by removing pipe plug and installing X-11562-2.

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 13

Page 16: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-190

EMERSON CLIMATE TECHNOLOGIES-SystemProtectors STAS Steel Liquid and Suction FilterDrier

Description ConnectionsLiquid Flow Capacity Tons @ 1 psi P 1, 2, 3

R-12 R-134a R-22 R-

407CR-404A

/507R-

502R-

410ASTAS-485T 5/8 ODF 16 21 22 21 15 14 22 STAS-487T 7/8 ODF 29 38 41 39 27 25 41 STAS-489T 1 1/8 ODF 42 53 58 56 38 36 58 STAS-4811T 1 3/8 ODF 48 75 81 78 53 41 80 STAS-4813T 1 5/8 ODF 67 81 89 85 58 58 87 STAS-967T 7/8 ODF 33 42 45 43 30 27 45 STAS-969T 1 1/8 ODF 49 65 71 68 47 42 71 STAS-9611T 1 3/8 ODF 62 80 87 83 57 54 86 STAS-9613T 1 5/8 ODF 67 92 100 95 65 58 99 STAS-1449T 1 1/8 ODF 48 66 72 69 47 41 71

STAS-14411T 1 3/8 ODF 69 92 100 96 65 60 99 STAS-14413T 1 5/8 ODF 77 93 101 97 66 66 100STAS-14417T 2 1/8 ODF 88 110 120 115 78 76 119STAS-19211T 1 3/8 ODF 75 94 102 98 67 64 101STAS-19213T 1 5/8 ODF 81 103 113 108 74 69 111STAS-19217T 2 1/8 ODF 91 113 123 117 80 78 1211 All ratings in accordance with ARI Standard 710-04. 86oF liquid refrigerant temperature • 5°F saturated vapor temperature • 3.1 lbs./min./ton for R-134a • 2.9 lbs./min./ton for R-22 and R-407C • 4.0 lbs./min./ton for R-404A/507 and R-12 2 For 2 PSI P, Multiply values by 1.4 3 For kW, multiply by 3.5

Replacement Parts For STASFlange Cover Assembly

PCN Flange Cover Assembly Description054046 All STAS Driers - Include Flange

Cover, Compression Spring, PipePlug, and Grade 5 Bolts

X12176-3

Shell Strainer AssemblyPCN Shell Strainer Assembly Description

060274 STAS-48 X27458-1060275 STAS-96 X27458-2060276 STAS-144 X27458-3060277 STAS-192 X27458-4

Miscellaneous PartsPCN Miscellaneous Parts Description

053121 Cover Bolts (Stainless Steel –suction line service)

X25787-7

037409 Access Valve (V Option) X11562-2027453 Cover Gasket (Includes felt set) X11983-1053812 Handle 26446-1053813 Inlet Retainer 26477-1060258 Spring 26439-1060278 Felt Set (1 Core Set) 27394-1027454 Gasket Set X11983-2061715 Mounting Bracket X28747-1

Mounting Backet for STAS 48* *More than one mounting bracket may be required for shel l sizes 96 and above. Exploded View

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 14

Page 17: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-191

EMERSON CLIMATE TECHNOLOGIES-System Protectors ADKS Liquid and Suction Line FilterDrierThe ADKS is a replaceable core Filter Drier for use wi th CFC, HCFC, and HFC refrigerants in very large commercial air conditioning and refrigerant systems. Features • Full flow fittings for low pressure drop • Corrosion resistant epoxy powder paint finish • Sturdy steel shells for long life durability

Nomenclature examp le: ADKS 30013T ADKS 300 13 TSystem

Protector Series

Unit Size (in cu. in.)

Connection Size (in 1/8”)

T = Tap Access Connection

Specifications• Filtration (with core): 40 microns • Maximum working pressure: 500 psig* • UL/CUL file number: SA 3124 • Bolt Torque: 35 ft-lbs *Note: Not suitable for R-410A applications above 500 psig

Dimensional Data

Ordering Information Dimensions (in)

PCN Connection Size A B C D E F* G H** Weight (lbs) Description026570 1 5/8 ODF 3 25.50 19.47 4.19 1.13 23.19 6.00 7.56 22.25 39.00 ADKS-30013T037978 2 1/8 ODF 3 25.59 19.00 3.78 1.69 23.19 6.00 7.56 22.25 39.00 ADKS-30017T032105 2 1/8 ODF 4 32.09 25.50 3.78 1.66 29.97 6.00 7.56 28.88 46.00 ADKS-40017T037570 2 5/8 ODF 4 33.13 26.72 4.81 1.47 29.97 6.00 7.56 28.88 46.00 ADKS-40021T

* Does not include weld bead ** “H” Dimension is the clearance required to change the internal hardware assembly T = 1/4” FPT access connection

ADKS Models are shipped without filter cores or filter drier cores. See filter or filter drier cores for availability.

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 15

Page 18: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-192

EMERSON CLIMATE TECHNOLOGIES-System Protectors ADKS Liquid and Suction Line FilterDrierCapacity Tables (in Tons)Liquid Line for Replaceable Block Type ADKS Filter Driers

Flow Capacity In Tons @ 1 psi ΔΔP 1, 2Description Connection

R-12 R-134a R-22/R-410A R-407C R-404/507 R-502ADKS 30013T 1 5/8 ODF 83 102 110 108 73 49ADKS 30017T 2 1/8 ODF 121 148 160 157 107 59ADKS 40017T 2 1/8 ODF 128 157 170 167 114 63ADKS 40021T 2 5/8 ODF 136 166 180 177 120 711 All ratings in accordance with ARI Standard 710-04. 86°F liquid refrigerant temperature

5oF saturated vapor temperature 3.1 lbs./min./ton for R-134a 2.9 lbs./min./ton for R-22 and R-407C 4.0 lbs./min./ton for R-404A/507 and R-12

2 For 2 PSI P. Multiply values by 1.4 Replacement Parts

PCN Flange Cover Description027467 ADKS-300, ADKS-400 X12176-2

PCN Shell Strainer Assembly Description039967 ADKS-300 X10574-5038315 ADKS-400 X10574-6

Exploded View

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 16

Page 19: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-193

EMERSON CLIMATE TECHNOLOGIES-System Protectors Filter Drier Cores and FiltersUniversa l replacement cores and filter cores for use in our ADKS and STAS shells and sim ilar competi tive Take-Apart type Filter Drier shells. May not be used for BTAS.

Features • Water capaci ties to sui t specific system conditions • Exceptional acid capacities for normal system protection,

or to effectively clean-up following a compressor burnout • Activated carbon blend for soluble contaminant and wax

removal (W-HH Series) Nomenclature example: H 48

Ordering Information and Capacity Tables

H 48 48 Series Cubic Inch

Specifications• Interchangeable with competitive products

NOTE: Filter Drier cores are suitable for use with R-11 AND R-123 but filters are NOT.

PCN RecommendedRefrigerant Type

Function R-1275°F

R-12125°F

R-134a75°F

R-134a125°F

R-2275°F

R-22125°F

R-407C75°F

R-407C125°F

R-404A/R-50775°F

R-404A/R-507125°F

R-410A75°F

R-410A125°F

R-50275°F

R-502125°F

059541 CFC, HCFC High Acid Removal 810 453 415 340 363 254 225 95 457 343 210 86 388 225 D-48059542 CFC, HCFC High Acid and Water

Removal1020 688 676 538 597 436 445 285 721 535 380 226 643 475 H-48

061235 CFC, HCFC, HFC Burnout Cleanup 772 488 387 294 335 226 290 165 417 289 249 130 444 306 W-48-HH061617 CFC, HCFC, HFC Universal

Replacement1579 1319 1272 1168 1181 1072 1033 786 1319 1241 976 707 1332 1150 UK-48

089338 CFC, HCFC High Acid and WaterRemoval

1958 1225 1112 834 962 673 726 418 1199 839 672 364 1109 758 H-100

062424 CFC, HCFC, HFC UniversalReplacement

3204 2740 2769 2550 2574 2345 2182 1682 2868 2710 - - 2787 2437 UK-100

043582 CFC, HCFC, HFC Burnout Cleanup 1668 1054 1077 812 938 621 629 363 1162 792 573 307 960 663 W-100-HH089559 CFC, HCFC, HFC Filter (Suction Only) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A F-48047664 CFC, HCFC, HFC Filter (Suction Only)

Reverse FlowN/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A F-48R

095762 CFC, HCFC, HFC Filter (Suction Only)) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A F-100061237 CFC, HCFC Removal 1020 688 1096 920 1037 790 750 530 1090 940 650 420 643 475 RH-48061238 CFC, HCFC Cleanup 772 488 583 493 532 380 380 230 600 482 350 197 444 306 RW-481 Water Capacities are based on:

Equ ilibrium Point Dryness (EPD) of: 50 parts per million for R-134a, R404-A/R-410A and R-407C 60 parts per million for R-22 15 parts per million for R-12

2 20 drops of water = 1 gram = 1 cc 3 D-42, H-42 and W-42 include one neoprene composite lid Gasket and one core gasket. All other cores include a universa l neoprene composi te gasket kit which includes 2 sizes of rep lacement lid gaskets, and gaskets for the top and bottom of the core or filter.

Dimensional Data

Filter Drier Block Size

Dimensions Weight (lbs)A B C

42 6.00 1.58 3.12 1.00 48 5.50 1.77 3.72 1.50

100 6.50 2.06 4.81 4.00

CatalogNumber

Dimensions Weight (lbs)A B C

F-48/F-48R 5.50 2.81 3.88 0.75 F-100 6.50 3.75 4.81 1.50

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 17

Page 20: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-194

EMERSON CLIMATE TECHNOLOGIES-System Protectors BTAS Brass Take-Apart Suction LineFilter DrierThe BTAS is a suction line, replaceable core Fil ter Drier for suction line services ideal for commercial ref rigeration app lications. Features • Full flow fittings for low pressure drop • Corrosion resistant brass body with stainless steel bolts • Specia l cartridge design exclusive to brass shell

Nomenclature examp le: BTAS 311SV BTAS 3 11 SVBrass

Take-Apart Series

Unit Size

Connection Size

(in 1/8”)

Suction Line

Service

Specifications• Filtration: 40 microns • Maximum working pressure: 400 psig • UL/CUL f ile number: SA 3124

Dimensional Data

Ordering InformationDimensions (in)

PCN Connection Size Nominal Shell Size (in) A B C D E Weight (lbs) Description049462 7/8 ODF 2 9.75 6.57 2.19 3.75 0.75 6.75 BTAS-27 S-V049465 1 1/8 ODF 3 10.31 6.81 3.31 4.63 0.91 10.25 BTAS-39 S-V049466 1 3/8 ODF 3 11.06 6.94 3.44 4.63 0.97 10.50 BTAS-311 S-V049467 1 5/8 ODF 3 11.25 7.13 3.63 4.63 1.09 11.00 BTAS-313 S-V049468 2 1/8 ODF 3 11.50 7.38 3.88 4.63 1.34 11.20 BTAS-317 S-V064169 1 3/8 ODF 4 11.41 7.81 4.13 5.75 0.78 16.20 BTAS-411 S-V049470 1 5/8 ODF 4 12.03 7.81 4.13 5.75 1.09 16.75 BTAS-413 S-V049471 2 1/8 ODF 4 12.28 8.06 4.13 5.75 1.34 17.20 BTAS-417 S-V049472 2 5/8 ODF 4 12.41 8.19 4.94 5.75 1.47 18.00 BTAS-421 S-V049473 2 1/8 ODF 5 13.44 8.41 4.19 7.09 1.34 28.75 BTAS-517 S-V049474 2 5/8 ODF 5 13.56 8.47 4.94 7.09 1.47 29.00 BTAS-521 S-V049475 3 1/8 ODF 5 13.25 8.16 4.63 7.09 1.66 29.25 BTAS-525 S-V

BTAS models are shipped without filter cartridge or Filter Drier cartridge.

Type A-F Replaceable Filter CartridgesPCN Filter Core For Shell No. Core O.D. Core Length Filter Area (Sq. In.) Weight (lbs)

049479 A2F BTAS-2 1 29/32 6 3/8 66 0.33049480 A3F BTAS-3 2 3/4 6 7/8 115 0.50049481 A4F BTAS-4 3 3/4 7 1/2 189 0.88049482 A5F BTAS-5 4 5/16 8 1/2 270 1.00

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 18

Page 21: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-195

EMERSON CLIMATE TECHNOLOGIES-System Protectors BTAS Brass Take-Apart Suction LineFilter DrierType A-F-D Replaceable Filter Drier Cartridges

PCN Filter Drier Cartridge For Shell No. Cartridge O.D. Cartridge Length Desiccant Volume (Cu. In.) Weight (lbs)049483 A2F-D BTAS-2 1 29/32 6 3/8 4.2 0.50049484 A3F-D BTAS-3 2 3/4 6 7/8 13.3 0.88049485 A4F-D BTAS-4 3 3/4 7 1/2 26.0 1.20049486 A5F-D BTAS-5 4 5/16 8 1/2 36.5 1.20

Replacement Parts*PCN Misc. Parts Description

037409 Access Valve X11562-2065970 BTAS 2 Repair Kit KD-30519-2065971 BTAS 3 Repair Kit KD-30519-3065972 BTAS 4 Repair Kit KD-30519-4065973 BTAS 5 Repair Kit KD-30519-5

* Repair kits contain cover bolts, cover, spring and seal ring.

Exploded View

BTAS models are shipped without f ilter cartridge or Filter Drier cartridge.

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 19

Page 22: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-196

EMERSON CLIMATE TECHNOLOGIES-System Protectors ASD Premium Suction Line Filter DrierThe ASD is a premium suction l ine Filter Drier for use with CFC, HCFC and HFC refrigerants. The ASD is optimized for high moisture, acid, and solid contaminant removal.

Features • Outstanding filtration for ultimate compressor protection • Dual access valves for easy pressure readings • Solid copper connections • Corrosion resistant epoxy powder paint finish

Nomenclature examp le: ASD 35S5VV ASD 35 S 5 VV

Series Unit Size (in cu. in.)

Connections S = ODF F = SAE

Connection Size

(in 1/8”)

Dual Access Valves

Specifications• Filtration: 40 microns • Maximum working pressure: 500 psig • UL/CUL f ile number: SA 3124

Ordering InformationDimensions (in)

PCN Connection Size A B C D E Weight (lbs) Description056352 3/8 SAE 5.59 -- 0.44 4.13 3.69 2.00 ASD 28F3049168 3/8 ODF 5.59 4.72 0.44 4.13 3.69 2.00 ASD 28S3-W049169 1/2 ODF 5.69 4.69 0.50 4.13 3.69 2.00 ASD 28S4-W049170 5/8 SAE 7.56 -- -- 4.75 3.69 2.50 ASD 35F5-W049171 5/8 ODF 6.22 5.28 0.63 4.75 3.69 2.50 ASD 35S5-W049172 3/4 ODF 7.75 6.50 0.63 5.56 3.69 3.00 ASD 45S6-W049173 7/8 ODF 7.94 6.44 0.75 5.56 3.69 3.00 ASD 45S7-W049174 1 1/8 ODF 8.84 7.03 0.91 6.13 3.69 3.50 ASD 50S9-W049175 1 3/8 ODF 12.25 10.31 0.97 8.25 3.69 5.00 ASD 75S11-W049176 1 5/8 ODF 12.16 9.91 1.13 8.25 3.69 5.00 ASD 75S13-W

Dimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 20

Page 23: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-197

EMERSON CLIMATE TECHNOLOGIES-System Protectors SFD Suction Line Filter DrierThe SFD is a standard suction line Filter Drier for use after a burnout or when ma jor work has been performed. It is for use with CFC, HCFC and HFC refrigerants.

Features • Solid copper connections • Dual access valves for easy pressure read ings • Corrosion resistant epoxy powder paint finish

Nomenclature example: SFD 13S5-VV SFD 13 S 5 VV

Series Unit Size (in cu. in.)

Connections S = ODF F = SAE

Connection Size

(in 1/8”)

Dual Access Valves

Specifications• Filtration: 40 m icrons • Maximum working pressure: 500 psig • UL/CUL file number: SA 3124

Ordering InformationDimensions (in)

PCN Connection Size A B C D Weight (lbs) Description064042 3/8 SAE - 3.38 5.50 3.13 2.00 SFD 08F3-W064044 3/8 ODF 5.31 3.38 6.19 3.13 2.00 SFD 08S3-W064043 1/2 SAE - 3.38 5.75 3.13 2.00 SFD 08F4-W064045 1/2 ODF 3.94 3.38 5.00 3.13 2.00 SFD 08S4-W064046 5/8 ODF 3.91 3.38 5.16 3.13 2.00 SFD 08S5-W064047 3/4 ODF 4.31 3.38 5.56 3.13 2.00 SFD 08S6-W060244 3/8 SAE - 3.38 5.50 3.69 2.00 SFD 13F3-W060245 3/8 ODF 3.97 3.38 4.84 3.69 2.00 SFD 13S3-W060246 1/2 ODF - 3.38 5.75 3.69 2.00 SFD 13S4-W060247 1/2 SAE 3.94 3.38 4.94 3.69 2.00 SFD 13F4-W060248 5/8 SAE - 3.38 6.13 3.69 2.00 SFD 13F5-W060249 5/8 ODF 3.91 3.38 5.16 3.69 2.00 SFD 13S5-W060250 3/4 ODF 4.00 3.38 5.25 3.69 2.00 SFD 13S6-W060262 7/8 ODF 4.25 3.38 5.75 3.69 2.00 SFD 13S7-W056505 3/4 ODF 5.75 5.13 7.00 3.69 3.00 SFD 27S6-W060251 7/8 ODF 6.00 5.13 7.50 3.69 3.00 SFD 27S7-W060252 1 1/8 ODF 5.81 5.13 7.63 3.69 3.00 SFD 27S9-W060253 1 3/8 ODF 10.31 12.16 12.25 3.69 4.50 SFD 54S11-W060254 1 5/8 ODF 9.91 12.16 12.16 3.69 4.50 SFD 54S13-W

Dimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 21

Page 24: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-198

EMERSON CLIMATE TECHNOLOGIES-System Protectors CSFD Compact Suction Line Filter DrierThe CSFD has a compact solid desiccant core perfect for short lay-in app lications. The CSFD is used for moisture, acid and so lid contam inant removal. It is for use with CFC, HCFC and HFC refrigerants.

Features • Dual access valves for easy pressure readings • High acid removal capacity • Solid copper fittings for easiest brazing • Corrosion resistant epoxy powder paint finish

Nomenclature example: CSFD 14S4-VV CSFD 14 S 4 VVSeries Unit Size Connections

S = ODF Connection Size

(in 1/8”)Dual Access

Valves

Specifications• Fil tration: 40 m icrons • Maximum working pressure: 500 psig** • UL/CUL file number: SA 3124

Ordering InformationDimensions (in)

PCN Connection Size A B C Description062231 1/2 ODF 4.25 2.75 4.63 CSFD-14S4-W062232 5/8 ODF 4.50 2.75 4.63 CSFD-14S5-W062233 3/4 ODF 4.38 2.75 4.63 CSFD-14S6-W062234 7/8 ODF 4.56 2.75 4.63 CSFD-14S7-W062235 1 1/8 ODF 4.88 2.75 4.63 CSFD-14S9-W**

** 400 psig Maximum Working PressureDimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 22

Page 25: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-199

EMERSON CLIMATE TECHNOLOGIES-System Protectors ASK-HH Suction Line Filter DrierThe ASK utilizes a solid core with an activated carbon blend to maximize acid, moisture and wax removal. It is for use with CFC, HCFC and HFC refrigerants.

Features • Dual access valves for easy pressure readings • Corrosion resistant epoxy powder paint finish • Activated carbon blend for soluble contaminant and wax • Solid copper connections

Specifications• Filtration: 40 microns • Maximum working pressure: 500 psig • UL/CUL file number: SA 3124

Nomenclature example: ASK 165S-VV-HH ASK 16 5 S VV HH

Series Unit Size (in cu. in.)

Connection Size

(in 1/8”)

Connection S = ODF

Dual Access Valves

Charcoal Blend

Ordering InformationDimensions (in)

PCN Connection Size A B C D Weight (lbs) Description056508 5/8 ODF 6.38 5.13 0.63 4.63 2.00 ASK 165S-W-HH056509 3/4 ODF 6.75 5.50 0.38 4.63 2.00 ASK 166S-W-HH056510 7/8 ODF 6.94 5.26 0.75 4.63 2.00 ASK 167S-W-HH056511 3/4 ODF 9.69 8.56 0.63 7.50 3.75 ASK 306S-W-HH056512 7/8 ODF 9.88 8.38 0.75 7.50 3.75 ASK 307S-W-HH056513 1 1/8 ODF 10.19 8.38 0.94 7.50 3.75 ASK 309S-W-HH

* Dimension does not include weld beadDimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 23

Page 26: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

Refrigeration

Com

pres

sors

, Ch

iller

s, C

onde

nser

sM

otor

sEl

ectr

ical

Heat

ing

Com

pone

nts

Indo

or A

ir

Qual

ity

Ther

mos

tats

Oils

&

Chem

ical

sAc

cess

orie

s, S

uppl

ies

& C

omm

odit

ies

Tool

s &

In

stru

men

tsRe

frig

erat

ion

K-200

EMERSON CLIMATE TECHNOLOGIES-System Protectors ASF Suction Line FilterThe ASF is a specifically designed filter to protect the compressor from dirt and all solid contaminants.

Features • Dual access valves for easy pressure readings • Solid copper connections • Corrosion resistant epoxy powder paint finish

Nomenclature example: ASF 35S5-VV Specifications• Filtration: 40 microns • Maximum working pressure: 500 psig • UL/CUL file number: SA 3124

Ordering Information

ASF 35 S 5 VV

Series Unit Size (in cu. in.)

Connections S = ODF F = SAE

Connection Size(in 1/8”)

Dual AccessValves

Dimensions (in)PCN Connection Size A B C D E* Weight (lbs) Description

062961 1/2 ODF 4.38 3.38 0.50 2.88 2.63 1.50 ASF 11S4062962 5/8 ODF 4.63 3.38 0.63 2.88 2.63 1.50 ASF 11S5062963 7/8 ODF 6.50 5.00 0.75 4.13 3.06 2.00 ASF 28S7062964 1 1/8 ODF 7.41 5.61 0.91 4.13 3.06 2.00 ASF 28S7-VV049177 3/8 ODF 5.59 4.72 0.44 4.13 3.69 2.00 ASF 28S3-VV049178 1/2 ODF 5.69 4.69 0.50 4.13 3.69 2.00 ASF 28S4-VV049179 5/8 SAE 7.56 – – 4.75 3.69 2.50 ASF 35FS-VV049180 5/8 ODF 6.53 5.28 0.63 4.75 3.69 2.50 ASF 35S5-VV059999 3/8 SAE 7.69 – – 5.56 3.69 3.00 ASF 45F3-VV049181 3/4 ODF 7.75 6.50 0.63 5.56 3.69 3.00 ASF 45S6-VV049182 7/8 ODF 7.94 6.44 0.75 5.56 3.69 3.00 ASF 45S7-VV049183 1 1/8 ODF 8.84 7.03 0.91 6.13 5.00 3.50 ASF 50S9-VV063113 2 1/8 ODF 11.75 9.06 1.31 7.63 5.00 3.50 ASF 64S17-V063115 2 5/8 ODF 13.00 10.00 1.50 7.88 5.00 3.50 ASF 64S21-V049184 1 3/8 ODF 12.25 10.31 0.97 8.25 5.00 5.00 ASF 75S11-VV049185 1 5/8 ODF 12.16 9.91 1.13 8.25 5.00 5.00 ASF 75S13-VV

* Dimension does not include weld beadDimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 24

Page 27: PAGE K175-K201 - SYSTEM PROTECTORS - Totaline K175-K201 - SYSTEM PROTECTORS.pdfEMERSON CLIMATE TECHNOLOGIES-System Protectors EK Liquid Line Filter Drier The EK Liquid Line Filter

RefrigerationCo

mpr

esso

rs,

Chill

ers,

Con

dens

ers

Mot

ors

Elec

tric

alHe

atin

g Co

mpo

nent

sIn

door

Air

Qu

alit

yTh

erm

osta

tsOi

ls &

Ch

emic

als

Acce

ssor

ies,

Sup

plie

s &

Com

mod

itie

sTo

ols

&

Inst

rum

ents

Refr

iger

atio

n

K-201

EMERSON CLIMATE TECHNOLOGIES-System Protectors APD Pulsation Dampener/MufflerThe APD series is designed to reduce noise and vibration on the compressor discharge lines.

Features • Compact size • Full flow fittings • Solid copper connections • Corrosion resistant epoxy powder paint finish • Rugged steel she lls for vibration resistance • Shock resistant steel shel l construction

Nomenclature example: APD 053 SB APD 05 3 S B

Pulsation Dampener

Cubic Inches

Fitting Size in 1/8”

ODF Fittings

With Baffles (omit for

standard)

Specifications• Maximum working pressure: 680 psig • Operating Range: -40°F to +250°F • UL/CUL f ile number: SA 5760

F low CapacityFitting Size Tons

1/4 1-53/8 5-101/2 10-205/8 15-257/8 25-35

1 1/8 35+Ordering Information

Dimensions (in)PCN A B C D E F Description

061862 6.00 5.00 4.47 3.02 0.50 0.50 APD 1R049651 4.56 3.56 3.00 2.63 0.50 0.50 APD 054 S-B059144 6.25 5.38 4.75 2.63 0.38 0.38 APD 163 S049623 6.25 5.38 4.75 2.63 0.38 0.38 APD 163 S-B060119 6.56 5.31 4.75 2.63 0.63 0.63 APD 165 S-B056989 10.25 8.44 7.50 3.13 1.13 0.88 APD 309 S

Dimensional Data

Sec#10 Refridge 53pages 2011_Fridge 12/10/2010 12:32 PM Page 25