page:date: 26.2.2010code: p021/30a1 clarity chromatography software clarity 3.0 – new features
TRANSCRIPT
page: Date: 26.2.2010Code: P021/30A
1
Clarity Chromatography Software
Clarity 3.0 – New features
page: Date: 26.2.2010Code: P021/30A
2
More than 100 new features in version 3.0
Calibration
Import/Export
Chromatogram
Event table
User Interface
Reports
Sequence
page: Date: 26.2.2010Code: P021/30A
3
Opening the Clarity Instrument
Select your Project during
the logon
Option to select project in Login Dialog
Auto Lock - option to lock Instrument after predefined period
page: Date: 26.2.2010Code: P021/30A
4
Improvements in user interface
User Options - new tab Directories to set paths for PDF reports, exports and imports
Tables - function Fill series
(Sequence, Calibration, Gradient)
page: Date: 26.2.2010Code: P021/30A
5
CalibrationBracketing, Standard Addition, Normalization
Improved Identification Windows
Forced Compound Identification
New Calibration curves, Linearization of Calibration Graph Axes
Calculation by Response of Another Compound
Response factor as Amount/Response or Response/Amount
Response Correction Factor
page: Date: 26.2.2010Code: P021/30A
6
Calibration Options
Calibration curve check
Failure displayed in the Peak Type
column in Result Table
New Calculation types
NORMSTDADD
page: Date: 26.2.2010Code: P021/30A
7
Linearization of axes in Calibration
Select appropriate function to
linearize the values on X, Y
axes
Show linearized values in
Graph Properties
page: Date: 26.2.2010Code: P021/30A
8
New Curve Fit Types in Calibration
Select a new curve:• ln• log10• exp• pow10• Hyperbola• Half Sigmoid
page: Date: 26.2.2010Code: P021/30A
9
ChromatogramUser columns – compound name in special values
Mathematical operations – invert function to reverse polarity
Advanced peak tags
File open dialog – option to change overlay mode
Result table – peak type indicates more info
Support for electronic signatures in PDF reports
page: Date: 26.2.2010Code: P021/30A
10
Enhanced Peak Type info
Peak Type in Result Table indicates used calibration options
Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied
Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied
page: Date: 26.2.2010Code: P021/30A
11
Overlay mode
Change to Overlay mode in
Open Chromatogram
dialog
page: Date: 26.2.2010Code: P021/30A
12
Electronic signatures in PDF reports
page: Date: 26.2.2010Code: P021/30A
13
Force Peak Identification
Force Peak Identificati
onSelect Peak
to Force
Select new Peak
Identification
Name peaks without calibration file
Override identification by calibration
Name peaks without calibration file
Override identification by calibration
page: Date: 26.2.2010Code: P021/30A
14
Relative Retention Times
Force Peak Identificati
on
Calculated RRT
Setup User Column using
the Special Values,
Compound option
page: Date: 26.2.2010Code: P021/30A
15
Customizable order of Report Sections
Right click the tab and adjust its
position
page: Date: 26.2.2010Code: P021/30A
16
Export of graphsExport of graphs from PDA view
Export Calibration curve as picture
[g/kg]Amount
0,0 0,5 1,0 1,5 2,0 2,5 3,0
[mV.s]
Res
pons
e
0
50
100
150
page: Date: 26.2.2010Code: P021/30A
17
Export of data in Excel (.xls) format
page: Date: 26.2.2010Code: P021/30A
18
Import Chromatogram Data
Store your preferences
for future use(user specific)
Import of multiple signal
chromatogram data
aranged in columns
Preview the imported data
file
Preview the imported data
file
Apply same settings to
multiple files opened
simultaneously
page: Date: 26.2.2010Code: P021/30A
19
Event tableEvents could be performed outside run
New input conditions
New output actions
Resizable dialog and columns width
New set of event for
running/idle state of
Instrument
New set of commands in
Output
page: Date: 26.2.2010Code: P021/30A
20
Valve control Set custom
position for Valve at Close Instrument
Input/Output names instead of
numbers
Set custom position for Valve
at Close Instrument
page: Date: 26.2.2010Code: P021/30A
21
SequenceBypass to perform run without injection for
startup and shutdown methods
New file name variables
%P – Project%s – Sequence%J – Method
New columns:• Include in SST – perform SST
test when injection is finished
• Stored Calib. – chromatogram will be opened with stored calibration
• Close All – close all currently opened chromatograms in overlay to prepare for next summary report
page: Date: 26.2.2010Code: P021/30A
22
Bracketing and Standard Addition
Calibration and Sequence Usage
Clone calibration at each Sequence start
Standard AdditionBracketing
This calibration will be used with Calibration used as
specified by user
Copy of the Example Calibration will be created according to Sequence options,
Calibration and Sequence Usage
page: Date: 26.2.2010Code: P021/30A
23
Extension and Control ModulesPDA – option Add All Identified Peaks to
Spectrum library
FC GP – new option Collect all
Flow rate units options extended to L/min, mL/min, µL/min
page: Date: 26.2.2010Code: P021/30A
24
Control Modules in development
Agilent 7890 GC
Agilent 1200 HPLC DAD (G1315D)
Sedere ELSD detector 80LT and 85LT
PG Instruments LC-200 HPLC
page: Date: 26.2.2010Code: P021/30A
25