panel and motor control components overview...

36
Panel and Motor Control Components Overview Catalogue The cost effective alternative www.klinkmann.com Wide international approvals: C US LISTED

Upload: nguyentuong

Post on 20-Apr-2018

226 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

Panel and Motor Control Components Overview Catalogue

The cost effective alternative

www.klinkmann.com

Wide international approvals:R

RC US LISTED

Page 2: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

CONTENTS

MCBs ......................................................................................................3

RCDs ......................................................................................................5

RCBOs ....................................................................................................6

MCCBs ...................................................................................................8

ACBs .....................................................................................................12

Contactors ...........................................................................................15

Starters ................................................................................................22

Pushbuttons & Indicators ...................................................................27

Modular Pushbuttons & Indicators & Disconnectors .......................30

Accessories ..........................................................................................32

Switch Disconnectors .........................................................................34

Page 3: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

3

MCB

R

RC US LISTED

NB1 Miniature Circuit Breaker

1. General1.1 Short circuit protection1.2 Overload protection1.3 Switch1.4 Isolation1.5 Contact position indicator1.6 Advanced current-limit Technology1.7 Heat dissipation gap for better cooling1.8 Extendable DIN-rail holder for easy installation

NB1

2. Technical features

Standard IEC/EN60898-1

IEC/EN60947-2 UL1077 UL1077

1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63

1P, 2P, 3P, 4P 1P, 2P, 3P, 4P 1P, 2P, 3P, 4P 1P, 2P

240/415 240/415 277/480 110/125

50/60Hz DC

6000/10000 6k 5k 10k

3

6000

B, C, D 8-12In B, C, D 4-7In, 7-14In

8, 000

20, 000

On DIN rail EN 60715 (35mm) by means of fast clip device

From top and bottom

Yes

Yes

Yes

Yes

Rated current In

Poles

Rated voltage Ue

Rated frequency

Rated breaking capacity

Energy limiting class

Rated impulse withstand voltage(1.2/50) Uimp

Thermo-magnetic release characteristic

Mounting

Connection

Auxiliary contact

Shunt release

Under voltage release

Alarm contant

Electrical life

Mechanical life

A

V

A

V

B, C, D curve

3. CurveIEC/EN 60898-1

MCBsMCBs

Page 4: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

4

NB1 6kA 1P B1 12NB1 6kA 1P B2 12NB1 6kA 1P B3 12NB1 6kA 1P B4 12NB1 6kA 1P B6 12NB1 6kA 1P B10 12NB1 6kA 1P B13 12NB1 6kA 1P B16 12NB1 6kA 1P B20 12NB1 6kA 1P B25 12NB1 6kA 1P B32 12NB1 6kA 1P B40 12NB1 6kA 1P B50 12NB1 6kA 1P B63 12 NB1 6kA 1P C1 12NB1 6kA 1P C2 12NB1 6kA 1P C3 12NB1 6kA 1P C4 12NB1 6kA 1P C6 12NB1 6kA 1P C10 12NB1 6kA 1P C13 12NB1 6kA 1P C16 12NB1 6kA 1P C20 12NB1 6kA 1P C25 12NB1 6kA 1P C32 12NB1 6kA 1P C40 12NB1 6kA 1P C50 12NB1 6kA 1P C63 12 NB1 6kA 1P D1 12NB1 6kA 1P D2 12NB1 6kA 1P D3 12NB1 6kA 1P D4 12NB1 6kA 1P D6 12NB1 6kA 1P D10 12NB1 6kA 1P D13 12NB1 6kA 1P D16 12NB1 6kA 1P D20 12NB1 6kA 1P D25 12NB1 6kA 1P D32 12NB1 6kA 1P D40 12NB1 6kA 1P D50 12NB1 6kA 1P D63 12 NB1 6kA 2P C6 6NB1 6kA 2P C10 6NB1 6kA 2P C13 6NB1 6kA 2P C16 6NB1 6kA 2P C20 6NB1 6kA 2P C25 6NB1 6kA 2P C32 6NB1 6kA 2P C40 6NB1 6kA 2P C50 6NB1 6kA 2P C63 6

NB1 6kA 2P D4 6NB1 6kA 2P D6 6NB1 6kA 2P D10 6NB1 6kA 2P D13 6NB1 6kA 2P D16 6NB1 6kA 2P D20 6NB1 6kA 2P D25 6NB1 6kA 2P D32 6NB1 6kA 2P D40 6NB1 6kA 2P D50 6NB1 6kA 2P D63 6 NB1 6kA 3P B6 4NB1 6kA 3P B10 4NB1 6kA 3P B13 4NB1 6kA 3P B16 4NB1 6kA 3P B20 4NB1 6kA 3P B25 4NB1 6kA 3P B32 4NB1 6kA 3P B40 4NB1 6kA 3P B50 4NB1 6kA 3P B63 4 NB1 6kA 3P C1 4NB1 6kA 3P C2 4NB1 6kA 3P C3 4NB1 6kA 3P C4 4NB1 6kA 3P C6 4NB1 6kA 3P C10 4NB1 6kA 3P C13 4NB1 6kA 3P C16 4NB1 6kA 3P C20 4NB1 6kA 3P C25 4NB1 6kA 3P C32 4NB1 6kA 3P C40 4NB1 6kA 3P C50 4NB1 6kA 3P C63 4 NB1 6kA 3P D4 4NB1 6kA 3P D6 4NB1 6kA 3P D10 4NB1 6kA 3P D13 4NB1 6kA 3P D16 4NB1 6kA 3P D20 4NB1 6kA 3P D25 4NB1 6kA 3P D32 4NB1 6kA 3P D40 4NB1 6kA 3P D50 4NB1 6kA 3P D63 4 S9 Shunt Release for NB1 V9 Under Voltage Release for NB1 F9 Auxiliary contact for NB1

NB1 Description Pack

Description Pack

MCBsMCBs

Page 5: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

5

1. General1.1 Protection against risk of fire1.2 Protection against risk of electric shock1.3 3 protection class: AC, A, 1.4 Tripping class

AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.

A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.

class can be used as upstream group switch for selective tripping contrary to a downstream standard RCCB

1.5 Rated residual operating current30mA- to give a high degree of protection against electric shock in a situation where supplementary protection against shock from accidental direct contact is required when itmust be able to trip within 40 milliseconds when a fault current of 150mA is detected. 100mA- to give a degree of protection against electric shock due to indirect contact situation.300mA- to gives overall protection against risk of fire form electrical faults in wiring etc, only where sufficient current (typically less than 500mA) may cause incandes-cence of metal parts in suitable circumstances and in consideration that installed over current devices would require far in excess of 300mA to operate.

1.6 Fault current indicator

RCDs

NL1 6KA 2P 25A 30mA A-TYPE 1NL1 6KA 2P 40A 30mA A-TYPE 1NL1 6KA 2P 63A 30mA A-TYPE 1NL1 6KA 4P 25A 30mA A-TYPE 1NL1 6KA 4P 40A 30mA A-TYPE 1NL1 6KA 4P 63A 30mA A-TYPE 1

NL1 10kA 2P 25A 30mA A-TYPE 1NL1 10kA 2P 40A 30mA A-TYPE 1NL1 10kA 2P 63A 30mA A-TYPE 1NL1 10kA 4P 25A 30mA A-TYPE 1NL1 10kA 4P 40A 30mA A-TYPE 1NL1 10kA 4P 63A 30mA A-TYPE 1

NL1 Description Pack

Description Pack

s

s

s

NL1 Residual Current Operated Circuit Breaker without over-current protection (Magnetic)

2. Technical features

Standard IEC/EN 61008-1

Type (wave form of the earth leakage sensed)

Rated current In

Poles

Rated voltage Ue

Rated sensitivity I∆n

Short-circuit current Icn=I∆c

Electrical life

Mechanical life

Terminal connection type

Mounting

Connection

AC, A,

25, 40, 63, 80, 100

2P, 4P

230/400

0.03, 0.1, 0.3

6000/10000

2, 000

2, 000

Cable/U-type busbar/Pin-type busbar

On DIN rail EN 60715 (35mm)

by means of fast clip device

From top and buttom

A

V

A

V

NL1

RCDs

Page 6: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

6

3. Сurve

NB1L Residual Current Operated Circuit Breakerwith over-current protection(Magnetic)

1. General1.1 Protection against risk of fire1.2 Protection against risk of electric shock1.3 Protection against overload1.4 Protection against short circuit1.5 Contact position indicator

NBL1

NBL1

2. Technical features

A

A

V

A

s

IEC/EN 61009-1

AC, A

B, C

Standard

B, C curve

t(s)

100005000

1h20001000

500200100

502010

521

0.50.20.1

0.050.020.01

0.0050.0020.0010.5 1 2 34 5 7 10 20 30 5070100 200 I/In

C

B

IEC/EN 61009-1

Type (wave form of the

rarth leakage sensed)

Thermo-magnetic release characteristic

Rated current In

Poles

Rated voltage Ue

Rated sensitivity I∆n

Rated short-circuit capacity lcn

Break time under I∆n

Electrical life

Mechanical life

Mounting

Connection

MCB+add-onRCD block

Combined

MCB+add-on RCD block

MCB+add-on RCD block

1, 2, 3, 4, 6, 10, 13, 16,20, 25, 32, 40, 50, 63

1, 2, 3, 4, 6, 10, 13,16, 20, 25, 32, 40

1P+N, 2P, 3P, 3P+N, 4P

0.03, 0.1, 0.3

0.03

1P+N, 2PCombined

Combined

6,000/10,000

≤0.1

2,000

2,000

On DIN rail EN 60715 (35mm) bymeans of fast clip device

From top and bottom (for combined type)

From top (MCB+add-on RCD block)

230/400

RCBOs RCBOs

Page 7: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

7

RCBOs

4. Overall and Mounting Dimensions (mm)MCB+add-on RCD block Overall and Mounting Dimensions

NB1L(2) NB1L 1P+N B6 30mA A 6KA (COMBINED) 1NB1L 1P+N B10 30mA A 6KA (COMBINED) 1NB1L 1P+N B13 30mA A 6KA (COMBINED) 1NB1L 1P+N B16 30mA A 6KA (COMBINED) 1NB1L 1P+N B20 30mA A 6KA (COMBINED) 1NB1L 1P+N B25 30mA A 6KA (COMBINED) 1 NB1L 1P+N C6 30mA A 6KA (COMBINED) 1NB1L 1P+N C10 30mA A 6KA (COMBINED) 1NB1L 1P+N C13 30mA A 6KA (COMBINED) 1NB1L 1P+N C16 30mA A 6KA (COMBINED) 1NB1L 1P+N C20 30mA A 6KA (COMBINED) 1NB1L 1P+N C25 30mA A 6KA (COMBINED) 1

NB1L(3~) NB1L 4P 10A 30mA C A 10KA 1NB1L 4P 16A 30mA C A 10KA 1NB1L 4P 20A 30mA C A 10KA 1NB1L 4P 25A 30mA C A 10KA 1NB1L 4P 32A 30mA C A 10KA 1NB1L 4P 40A 30mA C A 10KA 1 NB1L 3P+N 10A 30mA C AC 6KA 1NB1L 3P+N 16A 30mA C AC 6KA 1 NB1L 3P+N 25A 30mA C AC 6KA 1

RCBO Modular DeviceDescription Pack

Description Pack

RCBOs

Page 8: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

8

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

Body Motor driven operating mechanism Front connection plate DIN rail adaptor

Thermo magnetic release Under-voltage release Rear connection plate Cage clamp terminal

Electronic release Shunt release Locking system(padlock) Mechanical interlock

Plug-in base Alarm contact Short terminal cover Communication module

Rotary manual operating handle Auxiliary contact Extended terminal cover

Adjustable type MCCBNM8

● Rated current from 16 to 1250A● Thermal-magnetic type/Electronic type/Magnetic-only type● Adjustable thermal & adjustable magnetic trip● 2P 3P 4P available● AC/DC applicable● 5-class breaking capacity from 25kA to 150kA● Ics=100%Icu(In 630A),Ics=150%Icu(In>630A)● Circuit breakers and auxiliaries comply with the following international standard:

IEC/EN 60947-1: general rulesIEC/EN 60947-2: circuit breakersIEC/EN 60947-3: switches, disconnectors, switch-disconnectors, etc.IEC/EN 60947-4: contactor and motor startersIEC/EN 60947-5.1 and following: control circuit devices and switching elements,

● Automatic control components. NM8 also comply with the specifications of the marine clas-sification companies.

● Certified for operation in pollution-degree III environments as defined by IEC standard 60947 (industrial environments).● Wide temperature range from -40°C to +70°C● A complete system of add-on modules for NM8

MCCBs

NM8

MCCBs

Page 9: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

9

MCCBs

Overall and Mounting Dimensions Overall and mounting dimensions of fixed type for front connection

3 POL 16-125 A NM8-125S-16A/3P 1NM8-125S-20A/3P 1NM8-125S-25A/3P 1NM8-125S-32A/3P 1NM8-125S-40A/3P 1NM8-125S-50A/3P 1NM8-125S-63A/3P 1NM8-125S-80A/3P 1NM8-125S-100A/3P 1NM8-125S-125A/3P 1 3 POL 100-250A NM8-250S-100A/3P 1NM8-250S-125A/3P 1NM8-250S-160A/3P 1NM8-250S-200A/3P 1NM8-250S-250A/3P 1 3 POL NM8S-400S-400A/3P 1NM8S-630S-630A/3P 1NM8S-800S-800A/3P 1NM8S-1250S-1250A/3P 1

Accessories DIN-MOUNTINGSET NM8-125A-3P 1CAGE CLAMP TERMINAL NM8 125 1x50мм2 1CAGE CLAMP TERMINAL CU/AL NM8 125 1x35-95мм2 1DIRECT HANDLE NM8-125 1DOOR OPERATING HANDLE NM8-125 1ALARM AUXILIARY CONTACTSET NM8 125-630 1 TERMINAL CU/AL NM8 250/NM8 125 2x35-150мм2 1DIRECT HANDLE NM8-250 1DOOR OPERATING HANDLE NM8-250 1 TERMINAL CU/AL NM8S 630 1x240мм2 1TERMINAL CU/AL NM8S 630 2x240мм2 1DIRECT HANDLE NM8-400/630 1DOOR OPERATING HANDLE NM8-400/630 1 TERMINAL CU/AL NM8S 1250 3x240мм2 1TERMINAL CU/AL NM8S 1250 4x240мм2 1

NM8Description Pack

Description Pack

140

157

255

370

240

357

474

570

56

62.5

100

120

112

125

200

240

72

82

95

132

79

88

113

144

103

126

168

206

15

17.5

22.5

35

30

35

45

70

60

70

90

140

30

35

45

70

90

105

140

210

120

140

185

280

6

6

6

7

L1 L2 H0 H1 H2 K K1 K2 G1 G2 W0 W1 W2 d(mm)

62

70

-

-

W3NM8-125

NM8S-125/NM8-250/NM8S-250

NM8-400, 630/NM8S-400, 630

NM8-800, 1250/NM8S-800, 1250

MCCBs

Page 10: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

10

MCCBs

Tehnical DataParametrs

Number of poles 2 3 4

AC 220V/230V/240V

AC 380V/400V/415V

AC 440V

AC 500V

AC 660V/690V

DC 250V (1P)

DC 500V (2P)

Rated ultimate short-circuit

breaking capacity

(kA RMS) Icu

Life(CO recycle)Mechanical

Electrical

Breaking capacity code

Rated service breaking capacity Ics= (%Icu)

Utilization category

Safety of insulation

Suitability for isolation

100

A

20,000

20,000

H

100

100

100

50

6

3535

AC 50/60Hz

DC

Electric characteristics as per IEC 60947-2 and EN60947-2

Rated current(A) In

Rated insulation voltage (V) Ui

Rated impulse withstand voltage (kV) Uimp

Rated operational voltage (V) Ue

16, 20, 25, 32, 40, 50, 63, 80, 100, 125

750

8

690

500

Protection

Release units

Over-load protectionShort-circuit protection

Auxiliaries for control and indication

Motor-driven mechanism

Manual, remote operated automatic source changeover systems

Shunt and under-voltage release

Auxiliary and alarm contact

Pad locking system

Mounting and connection accessories

Residual current protectionAdded on residual

current protection module

Mounting and connection

FixedFront connection

Rear connection

Plug-in

ManualHandle

Direct or extended rotary handle

Connection terminal

Front connection plate

Rear connection plateDIN rail adaptor

Plug-in type connection accessories

Terminal coversInterphase barrier

Dimension and weight

Front connection

Rear connection

Dimension(mm)W H L

Weight(kg)

Thermo-magnetic

62 140 79 90 140 79 120 140 79

0.85 1.2 1.6

DIN rail Front connection

R

150

150

130

70

8

50

50

S

85

50

50

35

5

H

100

100

100

50

6

H

100

100

100

50

6

3535

S

85

50

50

35

525

25

2525

3535

NM8 circuit breaker (Thermal-magnetic) NM8-1254 Frames Frame 1

2 3 4

100

A

H

100

100

100

50

8

3535

H

100

100

100

50

S

85

50

50

35

6

R1501501307010

100, 125, 160, 180, 200, 225, 250

750

8

690

500

70 157 88 105 157 88 140 157 88

1.5 2.1 2.8

Thermo-magnetic

H

100

100

100

50

8

3535

S855050356

2525

5050

2525

8

3535

NM8-250Frame 2

Fixed type-front connection

Fixed type-front connection

20,000

20,000

MCCBs

Page 11: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

11

MCCBs

4

H R

100

A

15,000

6000

S H

150

150

130

70

15

250, 315, 350, 400

750

8

690

500

140 255 113 185 255 113

7.5 10

Thermo-magnetic

_

3

S

85

70

50

35

10

2525

100

100

85

50

12

3535

5050

100

100

85

50

12

3535

85

70

50

35

10

2525

HR

70 70

65 65

50 50

20 20

50 50

_____

_

50

A

10,000 10,000

4000 4000

50 50_

630, 700, 800

750

8

690

500

_

__

_

_

___

_

___

_

17.5 23

Thermo-magnetic

SHSHS6550353010

65

50

35

30

10

3535

3535

3 43 4

HH R

65

50

35

30

10

70 70

65 65

50 50

20 20

50 50

_____

_

800, 1000, 1250

750

8

690

500

50

A

50 50_

_

__

_

_

___

_

___

_

Thermo-magnetic

SS65

50

3530

10

2317.5

3535

3535

4

NM8-400 NM8-800 NM8-1250NM8-630

A

15,000

4000

HR

85

70

50

35

10

250, 315, 350, 400, 500

750

8

690

500

7.5 10

Thermo-magnetic

_

3

S

140 255 113 185 210 280 370 196 280 370 196370 196 210 370 196255 113

2525

100

100 100100100 100

85

50

12

3535

150

150

130

70

15

5050

85

70

50

35

10

2525

100

100

85

50

12

3535

Frame 3 Frame 4

MCCBs

Page 12: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

12

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACBNA1

● Rated current from 200 to 6300A● Modulized mechanical part and accessories● The terminal of the control circuit on the front enables easy handling● Minimized arc space● 3P 4P available● Max. breaking capacity up to 120kA@400V● Drawout type/fixed type● Power supplied from either top bottom does no reduction in performance● Circuit breakers comply with IEC/EN 60947-2● Certified for operation in pollution-degree III environments as defined by IEC standard 60947 (industrial environments).● Temperature range from -5°С to +65°С● A complete system of add-on modules for NA1

NA1

Drawout type Auxiliary contact Wire-cable mechanical interlock Under-voltage release

Fixed type Locking-device Connecting-rod type mechanical interlock Motor-driven energy-storage mechanism

Intelligent controller Arcing chamber Shunt release Rotary handle

Operating mechanism Secondary connecting part Closing release Fixed plate

ACBs ACBs

Page 13: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

13

ACBs

Summary

5 basic frame sizes

For your various requirements, the Air Circuit Breaker NA1 includes 5 basic

frame sizes as followed.

ACBs

Page 14: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

14

Motor & Fixed 3P NA1-2000-630M 3P Motor/Fixed 1NA1-2000-800M 3P Motor/Fixed 1NA1-2000-1000M 3P Motor/Fixed 1NA1-2000-1250M 3P Motor/Fixed 1NA1-2000-1600M 3P Motor/Fixed 1NA1-2000-2000M 3P Motor/Fixed 1 NA1-3200-2000M 3P Motor/Fixed 1NA1-3200-2500M 3P Motor/Fixed 1NA1-3200-3200M 3P Motor/Fixed 1 NA1-4000-4000M 3P Motor/Fixed 1 NA1-6300-5000M 3P Motor/Drawable 1 NA1-6300-6300M 3P Motor/Drawable 1 4P NA1-2000-630M 4P Motor/Fixed 1NA1-2000-800M 4P Motor/Fixed 1NA1-2000-1000M 4P Motor/Fixed 1NA1-2000-1250M 4P Motor/Fixed 1NA1-2000-1600M 4P Motor/Fixed 1NA1-2000-2000M 4P Motor/Fixed 1 NA1-3200-2000M 4P Motor/Fixed 1NA1-3200-2500M 4P Motor/Fixed 1NA1-3200-3200M 4P Motor/Fixed 1 NA1-4000-4000M 3P Motor/Fixed 1 NA1-6300-5000M 3P Motor/Drawable 1 NA1-6300-5000M 4P Motor/Drawable 1

Manual & Fixed 3P NA1-2000-630M 3P Manual/Fixed 1NA1-2000-800M 3P Manual/Fixed 1NA1-2000-1000M 3P Manual/Fixed 1NA1-2000-1250M 3P Manual/Fixed 1NA1-2000-16000M 3P Manual/Fixed 1NA1-2000-2000M 3P Manual/Fixed 1 NA1-3200-2000M 3P Manual/Fixed 1NA1-3200-2500M 3P Manual/Fixed 1NA1-3200-3200M 3P Manual/Fixed 1 NA1-4000-4000M 3P Manual/Fixed 1 NA1-6300-5000M 3P Manual/Fixed 1 4P NA1-2000-630M 4P Manual/Fixed 1NA1-2000-800M 4P Manual/Fixed 1NA1-2000-1000M 4P Manual/Fixed 1NA1-2000-1250M 4P Manual/Fixed 1NA1-2000-16000M 4P Manual/Fixed 1NA1-2000-2000M 4P Manual/Fixed 1 NA1-3200-2000M 3P Manual/Fixed 1NA1-3200-2500M 3P Manual/Fixed 1NA1-3200-3200M 3P Manual/Fixed 1 NA1-4000-4000M 3P Manual/Fixed 1 NA1-6300-5000M 3P Manual/Fixed 1 NA1-6300-6300M 3P Manual/Drawable 1

NL1 Description Pack

Description Pack

ACBsACBs

Page 15: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

15

Contactors

NC6 Mini Contactor

NC1 Contactor

NC2 Contactor

NCH8 Modular AC Contactor

The NC6 Series Mini Contactor is used in remote motor (≤4kW) control application. Rating up to 690V, 9A (AC3). ----- (06A, 09A) Standard: IEC/EN 60947-4-1 Two kinds of mounting available: Normal type (without pins); Pin type (with pins) Ambient Temp: -5 ~ 40 °С Coil Voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V; Auxiliary contacts: NCF6-02 & NCF6-20 (2NO or 2NC) NCF6-13 & NCF6-31 (1NO & 3NC or 3NO & 1NC) NCF6-13 & NCF6-31 (4NO or 4NC)● Assemble with Thermal overload Relay NR2-11.5 to be a DOL Starter.

The NC1 Series Contactor is used in remote motor (≤45kW) control application. Rating up to 690V, 95A (AC3). ----- (09A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A) Standard: IEC/EN 60947-4-1 Ambient Temp: -5 ~ 40 °С Coil Voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V, 600V, 660V Coil Voltage (DC): 24V, 36V, 48V, 110V, 220; Side mounting Auxiliary contacts: NCF1-11C (1NO & 1NC) Top mounting Auxiliary contacts: F4-20 & F4-02 (2NO & 2NC) F4-13 &F4-31 (1NO & 3NC or 3NO & 1NC) F4-40 & F4-04 (4NO or 4NC) Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)● Assemble with Thermal overload Relay NR2 (or NRE8) to be a DOL Starter.● Assemble with another one & F4 & F5 & NR2 (or NRE8) to be a Star-Delta Starter called QJX2;● Assemble with a current limiting block to be a Capacitor Contactor.● Assemble with another one to be a reversing contactor;

The NC2 Series Contactor is used in remote motor (≤450kW) control application. Rating up to 690V, 630A (AC3). ----- (115A, 150A, 185A, 225A, 265A, 330A, 400A, 500A, 630A)Standard: IEC/EN 60947-4-1Ambient Temp: -5 ~ 40 °СCoil Voltage (AC): 110V, 127V, 220V, 230V, 380V, 400V;Top mounting Auxiliary contacts: F4-20 & F4-02 (2NO & 2NC) F4-13 &F4-31 (1NO & 3NC or 3NO & 1NC) F4-40 & F4-04 (4NO or 4NC)Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)

● Assemble with Thermal overload Relay NR2 to be a DOL Starter. ● Assemble with another one to be a reversing contactor;

1. General1.1 Certificates: a. NCH8-20: CE, SEMKO, ESC; b. NCH8-63: CE1.2 Electric ratings: up to 20A, 40A, 60A, 230V, AC50/60Hz;1.3 Utilization category: AC-1, AC-7a, AC-7b;1.4 Standard: IEC/EN 61095

RC US LISTED

RC US LISTED

RC US LISTED

Contactors

NCH8

NC6

NC1

NC2

Page 16: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

16

Contactors ContactorsTehnical Data

AC operation

AC coil operation

Items Model

AC-3AC-4AC-3AC-4

Rated operationalcurrent (A)

380/400V

660/690V

Rated insulation voltage (V AC)

220/230V380/400V660/690V

200V AC240V AC460V AC600V AC

ACACACPower of controlled

3-phasecage motor (AC-3)

AC-3AC-4

ElectricalOperating frequency(operations/h)

MechanicalAC-3AC-4

Electrical life( 10 operations)3

Mechanical life ( 10 operations)

Matched fuse type

6

93.56.61.56902.24

5.53355

1,200300

3,6001,00020010

RT16-20

125

8.92

6903

5.57.555

7.57.5

1,200300

3,6001,00020010

RT16-20

187.7123.8690

47.5107.57.51010

1,200300

3,6001,00020010

RT16-32

258.5184.46905.511157.5101515

1,200300

3,6001,00020010

RT16-40

NC1-09 NC1-12 NC1-18 NC1-25

20 20 32 40

kW

hp

Rated conventional heating current (A) AC-1

Frame Frame 1 (3P, 4P) Frame 2 (3P) Frame 3 (3P, 4P)

Page 17: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

17

ContactorsContactors

3212217.56907.515

18.510152020

600300

3,600800200

8RT16-50

4018.5349

69011

18.53015202525

600300

3,600800150

8RT16-63

50243912

69015223715203030

600300

3,600600150

8RT16-80

65284214

69018.5303720254040

600300

3,600600150

8RT16-80

803749

17.369022374525304040

600300

3,600600100

6RT16-100

954449

21.369025454530305050

600300

3,600600100

6RT16-125

NC1-32 NC1-40 NC1-50 NC1-65 NC1-80 NC1-95

50 60 80 80 95 95

Frame 4 (3P) Frame 5 (3P, 4P) Frame 6 (3P, 4P)

Page 18: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

18

Contactors ContactorsTehnical Data

Frame Frame 1 Frame 2

3P contactors AC coil operation

Model

Rated operational

current (A)

Rated Conventional heating current (A) AC-1

Frame Frame 1 Frame 2

380/400V AC

240V AC

660/690V AC

660/690V AC

415V AC

1000V AC

1000V AC

480V AC

600V AC

AC-3

AC-4

Power of controlled

3-phase cage motor

(AC-3)

Operating cycles

(operations /h) AC-3

Electrical life

( 10 operations) AC-3

Mechanical life

( 10 operations)

6

6

Model

Rated current A

Matched fuse

type

NC2-115 NC2-150 NC2-185

200

115

86

46

55

80

65

40

60

75

75

200

150

108

50

75

100

65

50

75

100

100

275

185

118

71

90

110

100

60

100

100

100

1,200

1.2

10

600

1

6

1,200

1.2

10

RT16-1

200

RT16-1

225

RT16-2

315

kW

hp

380/400V AC

4P contactors AC coil operation

Model

Rated operationalcurrent (A)

Conventional heating current A

380/400V AC

240V AC

660/690V AC

660/690V AC

415V AC

1000V AC

1000V AC

480V AC

600V AC

AC-3

AC-4

Power of controlled

3-phase cage motor

(AC-3)

Operating cycles

(operations /h) AC-3

Electrical life

( 10 operations) AC-3

Mechanical life

( 10 operations)

6

6

Model

Rated current (A)

Matched fuse

type

NC2-115

200

115

86

46

55

80

65

40

60

75

75

1,200

1.2

10

RT16-1

200

NC2-150

200

150

108

50

75

100

65

50

75

100

100

1,200

1.2

10

RT16-1

225

NC2-185

275

185

118

71

90

110

100

60

100

100

100

600

1

6

RT16-2

315

kW

hp

380/400V AC

Page 19: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

19

ContactorsContactors

Frame 2 Frame 3 Frame 4 Frame 5 Frame 6

Frame 2

NC2-225 NC2-265 NC2-330 NC2-400 NC2-500 NC2-630

275

225

137

90

110

129

100

75

125

125

125

315

265

170

112

132

160

147

100

150

150

150

380

330

235

155

160

220

160

450

400

303

200

200

280

185

630

500

353

232

250

335

335

800

630

462

331

335

450

450

600

1

6

600

0.8

6

600

0.8

6

600

0.8

6

600

0.8

6

600

0.8

6

RT16-2

315

RT16-2

355

RT16-3

450

RT16-3

560

RT16-4

750

RT16-4

950 (on request)

NC2-225

275

225

137

90

110

129

100

75

125

125

125

600

1

6

RT16-2

315

NC2-265

315

265

170

112

132

160

147

100

150

150

150

600

0.8

6

RT16-2

355

NC2-400

450

400

303

200

200

280

185

600

0.8

6

RT16-3

560

NC2-330

380

330

235

155

160

220

160

600

0.8

6

RT16-3

450

NC2-630

800

630

462

331

335

450

450

600

0.8

6

RT16-4

950 (on request)

Frame 3 Frame 4 Frame 5 Frame 6

Page 20: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

20

Contactors

23~32

30~40

37~50

48~65

55~70

63~80

80~93

NC1-40NC1-50NC1-65NC1-80NC1-95

NR2-93

40

40

63

63

80

80

100

63

100

100

100

125

125

160

NC1-32

NR2-36

23~32

28~36

40

40

63

80

NC1-09NC1-12NC1-18

NR2-11.5

1.25~2

1.6~2.5

2.5~4

4~6

5.5~8

7~10

9~13

0.1~0.160.16~0.250.25~0.40.4~0.630.63~11~1.6

1.25~21.6~2.52.5~44~6

5.5~87~109~13

12~1817~25

4

4

6

8

12

12

16

0.250.511224468

1212162025

6

6

10

16

20

20

25

22224466

10162020253550

NC1-09NC1-12NC1-18NC1-25NC1-32

NR2-25

Model ofcontactor

Assembled thermal over-load relayRecommended fuse type

aM gGModel Rated current (A)

NC1-09NC1-12NC1-18

NR2-11.5

0.1~0.16

0.16~0.25

0.25~0.4

0.4~0.63

0.63~1

1~1.6

0.25

0.5

1

1

2

2

2

2

2

2

4

4

Assembly with terminal over-load replay

Contactors

Page 21: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

21

Contactors

Model PictureTime-delay range Number of time-delay contactsF5-T0

F5-T2

F5-T4

F5-D0

F5-D2

F5-D4

0.1s~3s

0.1s~30s

10s~180s

0.1s~3s

0.1s~30s

10s~180s

N/O+N/C

N/O+N/C

N/O+N/C

N/O+N/C

N/O+N/C

N/O+N/C

ModelConfiguration of contacts

PictureNumber of N/O contact Number of N/C contact

F4-20

F4-11

F4-02

F4-40

F4-31

F4-22

F4-13

F4-04

2

1

0

4

3

2

1

0

0

1

2

0

1

2

3

4

F4 auxiliary contact

F5 auxiliary contact

NCF1-11C lateral side auxiliary contact

F4 -Number of N/C auxiliary contactNumber of N/O auxiliary contactAuxiliary contact assembly

0: time-delay range, 0.1s~3s2: time-delay range, 0.1s~30s2: time-delay range, 10s~180sT: making time-delay; D: breaking time-delayTime-delay module

Lateral side1 N/C contact1 N/O contactDesign sequence No.Auxiliary contact assemblyContactorCompany code

F5 -

N C F 1 - 1 1 C

Accessories to NC1

Contactors

Page 22: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

22

Starters

NS2 Manual Motor Starter

NS2

● The NS2 Series Manual Motor Starter is used in remote motor control application for Over-load, short circuit & phase failure. Rating up to 690V, 80A (AC3). ----- (0.1~1.16A, 0.16~0.25A, 0.25~0.4A, 0.4~0.63A, 0.63~1A, 1~1.6A, 1.6~2.5A, 2.5~4A, 4~6.3A, 6~10A, 9~14A, 13~18A, 17~23A, 20~25A, 16~25A, 25~40A, 40~63A, 56~80A)Standard: IEC/EN 60947-5-1Ambient Temp: -5 ~ 40 °СSide mounting Auxiliary contacts: NS2-AU20 (2NO) NS2-AU11 (1NO & 1NC)Front mounting Auxiliary contacts: NS2-AE20 (2NO) NS2-AE11 (1NO & 1NC)Under-voltage release: NS2-UV110, NS2-UV220, NS2-UV380,Shunt release: NS2-SH110, NS2-SH220, NS2-SH380,Fault signal contact & instantaneous auxiliary contact: NS2-FA0110 (1NC & 1NO) NS2-FA0101 (1NC & 1NC) NS2-FA1010 (1NO & 1NO) NS2-FA1001 (1NO & 1NC)

RC US LISTED

Starters

Ovell and Mountig Dimension (mm) for NS8 and NS2

Page 23: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

23

Starters

Technical Parametrs

Starters

Page 24: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

24

Starters

Technical Parametrs

Starters

Page 25: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

25

StartersStarters

Page 26: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

26

NC1 Series Contactor 3P NC1-0901(0910) 13P NC1-1201(1210) 13P NC1-1801(1810) 13P NC1-2501(2510) 13P NC1-3201(3210) 13P NC1-4011 13P NC1-5011 13P NC1-6511 13P NC1-8011 13P NC1-9511 1 NC2 Series Contactor 3P NC2-115 13P NC2-150 13P NC2-185 13P NC2-225 13P NC2-265 13P NC2-330 13P NC2-400 13P NC2-500 13P NC2-630 1 NC6 Series Contactor NC6-0601 (0610) 1NC6-0901 (0910) 1NC6-0901 (0910) 1NC6-0604 (0608) 1NC6-0904 (0908) 1 NCH8 Series Contactor NCH8-20/2P 1NCH8-63/4P 1 Auxiliary contacts F5 1F4-2 1F4-4 1NCF6-4 1NCF6-2 1NCF1 (Side Contact) 1 NC1 Accessory AC Coil for NC1 1CJX2(NC1)-09/12/18 1CJX2(NC1)-25/32 1CJX2(NC1)-40/50/65/80/95 1 Mechanical Interlock CJX2(NC1)-09/12/18/25/32 1CJX2(NC1)-40/50/65 1CJX2(NC1)-80/95 1

NR2 Series Thermal Overload Relay NR2-25G 0.1-0.16A 1NR2-25G 0.16-0.25A 1NR2-25G 0.25-0.4A 1NR2-25G 0.4-0.63A 1NR2-25G 0.63-1A 1NR2-25G 1-1.6A 1NR2-25G 1.25-2A 1NR2-25G 1.6-2.5A 1NR2-25G 2.5-4A 1NR2-25G 4-6A 1NR2-25G 5.5-8A 1NR2-25G 7-10A 1NR2-25G 9-13A 1NR2-25G 12-18A 1NR2-25G 17-25A 1NR2-36G 23-32A 1NR2-36G 28-36A 1NR2-93G 23-32A 1NR2-93G 30-40A 1NR2-93G 37-50A 1NR2-93G 48-65A 1NR2-93G 55-70A 1NR2-93G 63-80A 1NR2-93G 80-93A 1NR2-200G 80-125A 1NR2-200G 100-160A 1NR2-200G 125-200A 1

NS2 Series Manual Motor Starter NS2-25 0.1-0.16A 1NS2-25 0.16-0.25A 1NS2-25 0.25-0.4A 1NS2-25 0.4-0.63A 1NS2-25 0.63-1A 1NS2-25 1-1.6A 1NS2-25 1.6-2.5A 1NS2-25 2.5-4A 1NS2-25 4-6.3A 1NS2-25 6-10A 1NS2-25 9-14A 1NS2-25 13-18A 1NS2-25 17-23A 1NS2-25 20-25A 1

NS2-80B 16A-25A 1NS2-80B 25A-40A 1NS2-80B 40A-63A 1NS2-80B 56A-80A 1

NS2 AccessoryNS2-MC Pushbutton Box 1Shunt Release NS2-SH220 1Shunt Release NS2-SH380 1Fault Signal Contact/Auxilary contact NS2-FA1001 1NS2-AU11 1Under Voltage Release NS2-UV220 1Under Voltage Release NS2-UV380 1

ContactorsDescription Pack

Description Pack

Starters Starters

Page 27: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

27

Pilot Devices

NP2 Pilot Device

ND16 Indicator

The NP2 Series Pilot Device is used in remote circuit control and indication. Rating up to 230V, 4.5A (AC-15) or 110V, 0.6A (DC-13)Standard: IEC/EN 60947-5-1IP40; Drill Plan: Φ22mmElectrical Endurance: 500×103 circles for Flush & mushroom head type; 100×103 circles for Flush & mushroom other head type;Ambient Temp: -5 ~ 40°СContact blocks: 2pcs (max); Illuminated: Either illuminated or Non-illuminated available.Button: Either Momentary or Maintained type availableHolder: Either metal or plastic availableHead available: Flush head, Mushroom head, selector switch, double-head switch, indicatorHead colors available: Red, Black, Green, Blue, Yellow;

The ND16 Series Indicator is used in remote indication. Rating up to 400V (AC/DC) Standard: IEC/EN 60947-5-1IP65; Drill Plan: Φ22mmElectrical Endurance: 30×103 HoursAmbient Temp: -5~40 °СHead colors available: Red, Black, Green, Blue, Yellow;ND16-22A(S)/2: For AC/DC application, Flat-platform lampshade;ND16-22A(S)/4: For AC application, Flat-platform lampshade;ND16-22B(S)/2: For AC/DC application, Flat-round platform lampshade;ND16-22B(S)/4: For AC application, Flat-round platform lampshade;ND16-22C(S)/2: For AC/DC application, Arc-surface ripple lampshade;ND16-22C(S)/4: For AC application, Arc-surface ripple lampshade;ND16-22D(S)/2: For AC/DC application, Arc-surface round lampshade;ND16-22D(S)/4: For AC application, Arc-surface round lampshade;Note: (S) for compact type;

NP2

ND16

RC US LISTED

RC US LISTED

Metal head NP2-BA11 10NP2-BA21 10NP2-BA31 10NP2-BA42 10NP2-BA41 10

Plastic headNP2-EA11 10NP2-EA21 10NP2-EA31 10NP2-EA41 10NP2-EA42 10

Metal head twist releaseNP2-BS442 φ30mm 10NP2-BS541 φ40mm 10NP2-BS642 φ60mm 10

NP2 Selector SwitchesMetal head NP2-BD21 10NP2-BD33 10Plastic head NP2-ED21 10NP2-ED33 10

ND1622D2230VG 1ND1622D2230VR 1ND1622D2230VW 1ND1622D224VR 1ND1622D224VW 1ND1622D4230VW 1ND1622DS224VB 10ND1622DS224VG 1ND1622DS224VR 1ND1622DS224VW 1ND1622DS224VY 1ND1622DS4110VG 1ND1622DS4110VR 1ND1622DS4130VG 1ND1622DS4130VR 1ND1622DS4130VW 1ND1622DS4130VY 1ND1622DS4230VB 1ND1622DS4230VG 1ND1622DS4230VR 1ND1622DS4230VW 1ND1622DS4230VY 1G=green, R=red, Y=yellow, W=white, B=blue

NP2Description Pack

ND16Description Pack

Pilot Devices

Page 28: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

28

RC US LISTED

Pushbuttons

Pushbutton, NP2

Indicator Light, ND16

Metal-headed

Plastic-headed

Key switchNP2-BG

Double-headedbutton

NP2-BL8

Illuminated buttonNP2-BW3

Illuminated double-headed buttonNP2-BW8

Indicator lightNP2-BV

Key switchNP2-EG

Double-headedbutton

NP2-EL8

Illuminatedbutton

NP2-EW3

Illuminateddouble-headed button

NP2-EW8

Indicator lightNP2-EV

Economic indicatorlight

NP2-EV1

60mmmushroom button

NP2-BR

FlushbuttonNP2-BA

40mmmushroom button

NP2-BC

Mushroom button,stay-up,rotated to reset

NP2-BS

Selctor button withrotary knobNP2-BD

Selector button withrotary handle

NP2-BJ

FlushbuttonNP2-EA

40mmmushroom button

NP2-EC

60mmmushroom button

NP2-ER

Mushroom button, stay-up,rotated to reset

NP2-ES

Selctor buttonwith rotary knob

NP2-ED

Selector button withrotary handle

NP2-EJ

Seperated modulars HeadHead-metal

Flush buttonNP2-BA

40mmmushroom button

NP2-BC

60mmmushroom button

NP2-BR

Mushroom button,self-locking,rotated to reset

NP2-BS

Selector switchNP2-BD

RC US LISTED

ND16-22A ND16-22AS ND16-22B ND16-22BS ND16-22C ND16-22DND16-22CS ND16-22DS

PushbuttonsType Designation

Specification code (Refer to table below)

Derivative type (Refer to table below)Structure classes: B: Metal head; E: PlastDesign sequence number ButtonsCompany code

Page 29: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

29

Pushbuttons & Indicators

NP9 Pushbutton

ND9 Indicator Light

1. General1.1 Electric ratings: 230V, AC50/60Hz;1.2 Utilization category: AC-14;1.3 Rated conventional heating current lth: 16A;1.4 Rated operational current Ie: 6A;1.5 Rated insulation voltage Ui: 500V;1.6 Rated impulse withstand voltage Uimp: 5000 V;1.7 Protection grade: IP20;1.8 Standard: IEC/EN 60947-5-1;

2. Normal Operational and Mounting Conditions2.1 Ambient temperature: -5°C~+40°C, average temperature in 24 hours not exceed +35°C;2.2 Altitude: ≤ 2000m;2.3 Air conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20°C. Special measures should be taken to occurrence of dews;2.4 Mounting category: II, III;2.5 Pollution grade: II;2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°C.

3. Technical Data3.1 Life (operations): a. Electric life: 100×103

b. Mechanical life: 250×103

3.3 Assembly of contact: 1NC+2NO, 2NC+1NO, 3NO, 2NC+2NO (Not available for illuminated type)3.4 Technical data of signal lamp a. Rated operational voltage: AC/DC6.3V, AC/DC12V, AC/DC24V, AC/DC110V, AC/DC230V b. Rated operational current: ≤20mA3.5 Life: incandescence lamp≥1000h, neon lamp≥2000h, LED≥30000h

1. General1.1 Electric ratings: 230V, AC50/60Hz;1.2 Rated insulation voltage Ui: 500V;1.3 Protection grade: IP201.4 Rated operational current: ≤20mA1.5 Life: LED≥30000h;1.6 Standard: IEC/EN 60947-5-1

2. Normal Operational and Mounting Conditions2.1 Ambient temperature: -5°C~+40°C, average temperature in 24 hours not exceed +35°C;2.2 Altitude: ≤ 2000m;2.3 Air conditions:

At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, highe relative humidity is allowable under lower temperature. For example, RH could be 90% at +20°C Special measures should be taken to occurrence of dews;

2.4 Mounting category: II, III;2.5 Pollution grade: II;2.6 Mounting mode: TH35-7.5 standard rail, inclination between mounting and vertical plane not exceed 5°.

NP9

ND9

Pushbuttons & Indicators

Page 30: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

30

ND91G230V 1ND91R230V 1ND91W230V 1ND91Y230V 1ND923031 1ND923032 1ND923033 1ND92GR230V 1ND92WW230V 1ND9PR 1

Illuminated pushbuttonsNP9230VR2NO1NC 153021 10NP9230VG1NO2NC 153025 10NP9110VR2NO1NC 153027 10NP9110VG1NO2NC 153031 10NP9024VR2NO1NC 153033 10NP9024VG1NO2NC 153037 10

pushbuttonsNP9R2NO2NC 153053 10NP9G2NO2NC 153057 10

ND9Description Pack

NP9Description Pack

Pushbuttons & Indicators Pushbuttons & Indicators

Modular Switch DisconnectorsNH4 Switch Disconnector

1. General1.1 In the open position, It complies with the requirements of the isolating function.1.2 It is designed match NB series MCBs/RCBOs.

2. Technical features

Page 31: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

31

Main SwitchMain SwitchOrdering Information

Overall and Mounting Dimensions (mm) Overall and Mounting Dimensions

Page 32: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

32

Accessories for Din-rail products

Busbar

Busbar for MCB & RCD

3P 1 131510Pin Type

3P 1 131509Pin Type

ModelNumber of

polesLengthL (m)

1P

2P

3P

4P

1P

1P

2P

2P

1

1

1

1

1

1

1

1

Ordercode

Fork Type

Fork Type

Fork Type

Fork Type

Pin Type

Pin Type

Pin Type

Pin Type

131501

131502

131503

131504

131505

131506

131507

131508

Cross section(mm )2

16

16

16

16

16

20

16

20

16

20

L

L

L

L

L

L

L

L

L

L

Accessories for Din-rail products

Page 33: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

33

Accessories for Din-rail products

Model

Model

Feed-in from endcross section (mm )2

Number ofpoles

Number ofpoles

1-phase

LengthL (m)

LengthL (m)

Ordercode

Ordercode

Cross section(mm )2

Cross section(mm )2

4P

4P

1

1

131511

131512

Pin Type

Pin Type

2P

3P

1

1

Pin Type

Pin Type

131514

131515

10

10

2. Busbar for RCBO

16

20

2, 3 and 4 phase

I =IsE

max. current (A)

Feed-in from the middlemax. current (A)

Max. feed-in current (A)

10

63

12

65

16

80

20

90

25

100

35

130

10

63

16

80

25

100

36

130

100 110 130 150 180 220 100 130 180 220

Depends on the cross section for connection!

3. DIN rail

Model Order codeDIN rail 131550

L(m)1

Accessories for Din-rail products

Page 34: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

34

Switch Disconnectors

HH15-QA/QP Switch Disconnector

NH40 Switch Disconnector

HH15-QSA Fuse-switch Disconnector

NHR17 Fuse-Switch Disconnector

NHR17

HH15-QSA

NH40

HH15-QA/QP

Mainly used in the distributing and motor circuit which has high short-circuit current, and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment.They provide safety isolation and protection against overcurrent for any low voltage electrical circuit.Standard: IEC/EN 60947-3Rated current: 125-3150A

Nh40 series Switch-disconnector is applicable for AC 50Hz, rated voltage AC 690V and below, DC440V and below, rated current up to 3150A.It can be applied for manually infrequent making &breaking and disconnecting of the circuit. Products with Ith under 1000A can be used as load break switch. They provide safety isolation for any Low voltage circuit.Standard: IEC/EN60947-3.Rated current: 16-630A

Mainly used in the distributing and motor circuit which has high short-circuit current, and acted as main switch or master switch infrequently operated by hand, it is particularly suitable in the relative high class with drawable low voltage complete equipment.They provide safety isolation and protection against overcurrent for any low voltage electrical circuit.Standard: IEC/EN 60947-3.Rated current: 63-630A

NHR17 series fuse-swith disconector is a new product developed by our company. Rated insulation voltage up to 800V. rated operational voltage up to 690V. rated operational current up to 630A, rated frequency 50Hz, in the distribution circuit and motor circuit which has high short-circuit current as the power switch,isolating switch, emergency switch as well as circuit protection, but normally it is not used to make and break a single motor directly.Standard: IEC/EN 60947-3.Rated current: 160-630A

Switch Disconnectors

Page 35: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

35

NHR40 Fuse-switch disconnector

NHRT40 Vertical Fuse-switch disconnector

HH15/QAS/QPS/QSS Changeover Switch

NH40S Changeover Switch

NH40SZ Automatic Changeover Switch

NH40SZ

HH15/QAS/QPS/QSS

NH40S

NHRT40

NHR40

NHR40 series switch-disconnector with fuse is applicable in the circuit of AC50Hz, rated voltageAC690V and below, DC440V and below, rated current up to 630A.NHR40 series are infrequently manually operated multipolar fuse combination switches, They breakor switch off on load and provide safely isolation and protection against overcurrent for any voltageelectrical circuit.Standard: IEC/EN 60947-3.Rated current: 160-630A

NHRT40 series are infrequently manually operated multipolar fuse combination switches, They breakor switch off on load and provide safely isolation and protection against overcurrent for any voltageelectrical circuit.Standard: IEC/EN 60947-3.Rated current: 160-630A

Mainly used in the distributing and motor circuit which has high short-circuit current, and acted asmain switch or master switch infrequently operated by hand, it is particularly suitable in the relativehigh class with drawable low voltage complete equipment.They provide safety isolation and protection against overcurrent for any low voltage electrical circuit.Standard: IEC/EN 60947-3.Rated current: 125-3150A

Mainly used in the distributing and motor circuit which has high short-circuit current, and acted asmain switch or master switch infrequently operated by hand, it is particularly suitable in the relativehigh class with drawable low voltage complete equipment.They provide safety isolation and protection against overcurrent for any low voltage electrical circuit.Standard: IEC/EN 60947-3.Rated current: 160-630A

NH40SZ automatic changeover switch disconnector can realize automatic and manual changeoverbetween normal and back up power supply power, and stop power supplying to load when change-over process of power supply is carried out.The switch is applicable for two circuits power supply and in the condition which requires high quality power supply.Standard: IEC/EN 60947-3. 60947-6Rated current: 16-1600A

Switch DisconnectorSwitch Disconnectors

Page 36: Panel and Motor Control Components Overview Cataloguemedia.klinkmann.fi/catalogue/en/Chint/Chint_Panel_Motor_Control... · Panel and Motor Control Components Overview Catalogue The

The cost effective alternative

Panel and motor control components from the Asian market leader Chint is the largest manufacturer in Asia and one of the TOP3 global manufacturers of electrical panel and motor control components. Many well known international component suppliers supply Chint products under their own name and brand - you secure the most cost effective component sourcing by buying the Chint products directly from Klinkmann. Reliable Chint components offer good technical performance and they have wide international approvals - select Chint for the most optimal component sourcing.

Chint_Panel_Motor_Control_Components_Overview_en_0911.pdf

Samaratel. +7 846 273 95 [email protected]

Yekaterinburgtel. +7 343 376 [email protected]

St. Petersburgtel. +7 812 327 [email protected]

Moscowtel. +7 495 641 [email protected]

Helsinkitel. +358 9 540 [email protected]

Vilniustel. +370 5 215 [email protected]

Rigatel. +371 6738 [email protected]

Мinsktel. +375 17 200 [email protected]

Tallinntel. +372 668 [email protected]

Кievtel. +38 044 495 33 [email protected]

www.klinkmann.com