paper 7a 2011 final - hkia.net

14
Candidate Number : Seat Number : HKIA / ARB Professional Assessment 2011 Paper 7a CONSTRUCTION DETAILS & DOCUMENTATION (20 marks out of 100 marks of Paper 7) 30 November 2011 4:00 pm – 6:00 pm (2 hours) Kowloonbay International Trade & Exhibition Centre (KITEC) Kowloon Bay ONE COMPULSORY QUESTION General Notes Format Examination paper, both A3 plain and A3 tracing, are provided. Use as appropriate. Presentation Black ink line drawings.

Upload: others

Post on 27-Mar-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Microsoft Word - Paper 7A_2011_finalCandidate Number : Seat Number : HKIA / ARB Professional Assessment 2011 Paper 7a CONSTRUCTION DETAILS & DOCUMENTATION (20 marks out of 100 marks of Paper 7) 30 November 2011 4:00 pm – 6:00 pm (2 hours) Kowloonbay International Trade & Exhibition Centre (KITEC) Kowloon Bay
ONE COMPULSORY QUESTION
General Notes
Format Examination paper, both A3 plain and A3 tracing, are provided. Use as appropriate.
Presentation Black ink line drawings.
HKIA/ARB Professional Assessment 2011 Page 1 Paper 7a Construction Details & Documentation
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
CONTENTS
Attachment 1
Scale 1: 100
Attachment 2 Private House – Drawing List ---
1 Assignment Statement Your client is intending to build a private house built in reinforced concrete post and beam structural system. The schematic design was completed by your colleagues (see Attachment 1). You are then required to produce a set of coordinated construction documents based on the drawing in Attachment 1. You are required to prepare the specified construction details and schedule, as set out below for construction.
2 Submission Requirements
2a Drawing List :
Write on the table provided in Attachment 2. Complete a full list of architectural drawings for the preparation of tender document
2b Construction Details Scale 1: 5 (suggested)
Draw on the tracing paper(s) to show the following details: Detail P : steel balustrade at the outer
edge, showing waterproofing detail of roof.
Detail Q : aluminium door with glass panel, showing interface with external and internal floor finish.
The drawing should include but not limited to the following: • annotations, levels and dimensions; • material descriptions, etc.
END OF PAPER 7a
HKIA/ARB Professional Assessment 2011 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
Candidate Number : Seat Number : HKIA / ARB Professional Assessment 2011 Paper 7b BUILDING DESIGN (80 marks out of 100 marks of Paper 7) 1 December 2011 9:00 am – 5:00 pm (8 hours) Kowloonbay International Trade & Exhibition Centre (KITEC) Kowloon Bay
ONE COMPULSORY QUESTION General Notes
Format Examination paper, both A3 plain and A3 tracing, are provided. Use as appropriate.
Presentation Black ink line drawings are preferred. You may use color for clarity. Do NOT use RED.
HKIA/ARB Professional Assessment 2011 Page 1 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
CONTENTS
Contents
Pages 2 to 6 1 Problem Statement 2 Site Description 3 Design Brief 4 Submission Requirements
Attachment 1
Attachment 2
Site Plan
Scale 1: 200
Attachment 3 Minimum Standards of Turning Circle for Private Cars, Goods Vehicles and Tourist Bus
HKIA/ARB Professional Assessment 2011 Page 2 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
1 PROBLEM STATEMENT
Your Client, the campus office of a local university, intends to develop an existing open space into the School of Music. It is located in the heart of the university campus. The Site is surrounded by teaching blocks of other departments and also a student activity centre. Your task is to prepare a schematic design which satisfies generally all functional and statutory requirements, for presentation to the Client. Your design should incorporate preliminary provisions and requirements for building structure, building services, utilities and the like. The design should be sensitive to the Site and the university neighborhood.
2 SITE DESCRIPTION
Context The Site is a hypothetical site in the heart of a university campus. It is generally flat and served by major Road A and secondary Road B, both of which are more than 6m wide. The vicinity of the Site comprises of other teaching blocks and a student activity centre which are not more than 8 storeys high. See Attachments 1 & 2: Location Plan and Site Plan.
Vehicular Access
Vehicular access for private cars and service vehicles shall be through Road B.
Environmental Factors Traffic noise from the traffic roads is not significant.
HKIA/ARB Professional Assessment 2011 Page 3 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
3 DESIGN BRIEF
3.1 Development Requirements
Zoning Government, Institution or Community (G/IC)
Permissible GFA under Lease Use for teaching purpose and ancillary facilities = 5,000 s.m.
Permissible Plot Ratio (PR) and Site Coverage (SC)
Requirements under Buildings Ordinance shall be complied with.
Building Height Not higher than +68mPD (main roof)
Site Vehicular Access Vehicular access shall be between points X and Y through Z.
Car Parks NOT required for the purpose of this Paper
Loading and Unloading 2 nos. (3.5m x 7.5m x 3.5mH each)
Refuse Collection Vehicular access is NOT required for the purpose of this Paper.
Barrier Free Access Statutory requirements shall be complied with.
Lift(s) 2 nos. of passenger lifts (of shaft size minimum 2100mm x 2100mm) shall be provided
Minimum 1 no. of service lift (of shaft size minimum 2600mm x 2600mm) for the purpose of servicing and transport of musical instruments shall be provided.
HKIA/ARB Professional Assessment 2011 Page 4 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
Audio/Visual Control Room for Theatre
10
3.3 Accommodation Schedule
As appropriate Street level
Theatre cum Multipurpose Hall
500 Clear headroom to be 10m minimum
Classrooms (Type A) 50 x 4 nos. 2 of these classrooms shall be able to combine into 1 large classroom of area = 100s.m.
Classrooms (Type B) 20 x 6 nos.
Practice Rooms 10 x 8 nos.
Library / Reading Lounge 100
Kitchen 25 Separate access shall be provided for servicing
Stores 300 To be distributed on each floor. Access shall be provided to the service lift for transportation of musical instruments.
Backstage, Dressing Rooms and Storage
200
space on street level
Adjacent to the Main Entrance of the School of Music. The outdoor Performance Piazza is an important feature of the School and its design shall form an integral part of the building.
HKIA/ARB Professional Assessment 2011 Page 5 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
Gross Floor Area (s.m.)
As required and as appropriate
Sanitary Provisions for Common Areas
As appropriate
Transformer, Switch & Plant Rooms
HKIA/ARB Professional Assessment 2011 Page 6 Paper 7b Building Design
DO NOT TAKE answer scripts, question papers, provided reference materials, draft and loose sheets out of the examination hall
4 SUBMISSION REQUIREMENTS
Design Statement Describe Concepts and Design Intentions. Use text, sketches and diagrams as appropriate. Be concise and brief.
Site Plan suggested Scale 1:200
Show site development. Include access point(s) for pedestrians.
Plans of all major Levels suggested Scale 1:200
Indicate all major spaces and elements of construction. Label spaces according to the Accommodation Schedule. Note usable area of each space (only approximate figures are required).
Indicate Building Section cut-line(s). Give overall and critical dimensions. Show Site Boundary and adjacent structures. Show Means of Access for Firefighting & Rescue. Show Building Structure. Show provisions for M&E Rooms.
Building Section(s) suggested scale 1:100/ 200
Show floor to floor dimensions. Show relationship between the elements of construction (eg. interfaces and connections of building structure, building envelope, finishes, building services, and the like)
Include annotations and critical dimensions.
Illustration
Illustrate external massing, form, architectural features in minimum one drawing. Use either axonometric, or isometric, or perspective drawing(s) as appropriate.
Indicate major exterior finishes, textures and the like.
Calculations
Show compliance of design with - Permissible Plot Ratio - Permissible Site Coverage
Tables, Schedules and Calculations for exit widths, sanitary fitments, refuse rooms, and the like are NOT REQUIRED.
END OF PAPER 7b