Ethernet & IP Mobile Backhaul parallel measurements for test multiple Slave and Boundary Clocks simultaneously Paragon-t at-a-glance Save on me and equipment with the Calnex Paragon - t 1588v2 Sync-E E1, T1, 2M, 10M, 1PPS, ToD Apply multiflow, multi-PDV profiles using the Paragon-X and simultaneously measure the BC/SC clock and phase outputs using the Paragon-t 4 ports simultaneous Boundary Clock (BC) and Slave Clock (SC) frequency measurements 4 ports simultaneous phase measurements - 1pps 4 ports ToD (Time of Day) 4 ports MTIE, TDEV, clock MAFE and FFO pass/fail evaluation to standard or user masks Simultaneous testing of multiple 1588v2 Slave and Boundary Clocks 4 ports simultaneous Sync-E wander measurement to G.8262/G.8261 4 ports Sync-E ESMC monitoring with G.8264 decodes 4 ports MTIE, TDEV, clock MAFE and FFO pass/fail evaluation to G.8262/G.8261 standard or user masks Simultaneous Sync-E measurement 4 ports Sync-E clock measurement 1GbE, 100BT 4 ports clock measurement E1 (bal/unbal), T1 (bal), 10M (unbal), 2M (unbal) 4 ports phase measurement 1pps (bal/unbal) 4 ports ToD (Time of Day) Clock Reference input GPS Antenna, 64k, 2M, 6.3M, 10M, T1 BITS, E1 MTS 2 ports Clock Reference outputs 10MHz, 2MHz Multi-user capability

Upload: others

Post on 21-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: parallel measurements for Ethernet & IP Mobile Backhaul · Ethernet & IP Mobile Backhaul parallel measurements for test multiple Slave and Boundary Clocks ... Reference Clocks Lock

Ethernet & IP Mobile Backhaulparallel measurements for

test multiple Slave and Boundary Clocks

simultaneously

Paragon-t at-a-glance

Save on time and equipment with the Calnex Paragon -t1588v2 Sync-E E1, T1, 2M, 10M, 1PPS, ToD

Apply multiflow, multi-PDV profiles using the Paragon-X and simultaneously measure the BC/SC clock and phase outputs using the Paragon-t

4 ports simultaneous Boundary Clock (BC) and Slave Clock (SC) frequency measurements

4 ports simultaneous phase measurements- 1pps

4 ports ToD (Time of Day)

4 ports MTIE, TDEV, clock MAFE and FFOpass/fail evaluation to standard or user masks

Simultaneous testing of multiple 1588v2 Slave and Boundary Clocks

4 ports simultaneous Sync-E wandermeasurement to G.8262/G.8261

4 ports Sync-E ESMC monitoring with G.8264 decodes

4 ports MTIE, TDEV, clock MAFE and FFOpass/fail evaluation to G.8262/G.8261 standard or user masks

Simultaneous Sync-E measurement

4 ports Sync-E clock measurement1GbE, 100BT

4 ports clock measurement E1 (bal/unbal), T1 (bal), 10M (unbal), 2M (unbal)

4 ports phase measurement 1pps (bal/unbal)

4 ports ToD (Time of Day)

Clock Reference inputGPS Antenna, 64k, 2M, 6.3M, 10M, T1 BITS, E1 MTS

2 ports Clock Reference outputs 10MHz, 2MHz

Multi-user capability

Page 2: parallel measurements for Ethernet & IP Mobile Backhaul · Ethernet & IP Mobile Backhaul parallel measurements for test multiple Slave and Boundary Clocks ... Reference Clocks Lock

Precise synchronization in today’s evolving mobile backhaul network has never been so vital: Increasing usage of smart phones and other mobile devices means escalating traffic and demand for more and more bandwidth; the deployment of new technologies such as LTE means increased complexity; and crucially, almost all routers, Ethernet switches, MSPTs etc now support synchronization standards such as Sync-E (ITU-T G.8262) and PTP (IEEE 1588v2) as they integrate PTP Slave/Boundary Clock functionality.

Equally vital is ensuring NE’s synchronization mechanisms perform exactly the way they were designed – before deployment. And that means rigorously measuring frequency and time simultaneously. With the power to make lengthy simultaneous measurements, whether for long term Software

Small investment, big returnTest multiple NEs and Clocks simultaneously

Calnex Paragon-X Master Emulation(running multiflow multi-PDV)

References:E1/T110MHz/2MHzGPS Antenna

1588v2 Multi-Port Slave and Boundary Clock Testing

Calnex Paragon-t

~References:E1/T110MHz/2MHzGPS Antenna

Typical Time Saving:Single Slave Clock test = 24 hours typicalTesting 4 Slave Clocks sequentially = 4 daysUsing Paragon-t saves 3 days

4 Simultaneous Frequency Measurements4 Simultaneous Phase Measurements4 Simultaneous ToD Measurements

Freq. Meas. = 4 x E1, T1, 10MHz, 2 MHz, Sync-EPhase Meas. = 4 x 1pps Accuracy4 x ToD

Regression/System Verification Testing or during Acceptance and Installation Testing, the Calnex Paragon-t is quite simply the tool of choice.

The Paragon-t lets you make 4 Frequency, plus 4 Phase (1pps) and 4 ToD display measurements simultaneously. In other words, 12 simultaneous measurements saving you days of test time, greatly increasing test coverage, and saving on test equipment.

So if you need to verify multiple software releases each year, verify network equipment during vendor selection, acceptance test or field trials, or verify the Installation of synchronization equipment, now you can be sure your NEs meet performance and quality standards. Better still, the Paragon-t lets you do it faster, more thoroughly and with less equipment than ever before.

Freq

, Pha

se, T

oD

Freq

, Pha

se, T

oD

Freq

, Pha

se, T

oD

Freq

, Pha

se, T

oD

4 x Slave ClockSCSCSCSC

Paragon-X generates PDV impairments

~

Page 3: parallel measurements for Ethernet & IP Mobile Backhaul · Ethernet & IP Mobile Backhaul parallel measurements for test multiple Slave and Boundary Clocks ... Reference Clocks Lock

Calnex Paragon-X Master Emulation(running multiflow PDV)

Calnex Paragon-t

~References:E1/T110MHz/2MHzGPS Antenna

Freq. Meas. = 4 x E1, T1, 10MHz, 2 MHz, Sync-EPhase Meas. = 4 x 1pps Accuracy4 x ToD

Paragon-X generates PDV impairments

Wanderfree

Calnex Paragon-t

References:E1/T110MHz/2MHz64k, 6.3MHzGPS Antenna

G.8262 Multi-Port Sync-E Measurement

Wander Meas. = 4 x Sync-E (100BT, GbE)

4 x MTIE/TDEV Meas. vs G.8262 Mask

Sync-E

Sync-E

Sync-E

Sync-E

~

4 Simultaneous Sync-E Wander Measurements

Typical Time Saving:Sync-E noise gen test = 3,000s min.Testing 4 EECs sequentially = 12,000sUsing Paragon-t saves 9,000s = 2.5hrs

Calnex Paragon-t

Boundary and Slave Clock Benchmarking and ComparisonCompare the performance of:

Up to 4 different BCs and SCs from different NEMs against each other

Up to 4 versions of BC/SC software for version benchmarking

Freq, Phase, ToD

4 x Boundary Clock

Freq, Phase, ToDBC

BC

BC

BCFr

eq, P

hase

, ToD

Freq

, Pha

se, T

oD

Freq

, Pha

se, T

oD

Freq

, Pha

se, T

oD

4 x Slave ClockSCSCSCSC

~References:E1/T110MHz/2MHzGPS Antenna

EEC

EEC

EEC

EEC

Page 4: parallel measurements for Ethernet & IP Mobile Backhaul · Ethernet & IP Mobile Backhaul parallel measurements for test multiple Slave and Boundary Clocks ... Reference Clocks Lock

© Calnex Solutions Ltd, 2012.

www.calnexsol.com

Product Specifications

Physical Interfaces Ethernet: 4 off 1G, 100BT Electrical – RJ45, 4 off 1G Optical (SFP required) 4 ports E1, 10MHz, 2.048MHz – BNC (unbalanced) 4 ports E1, T1 – RJ48 (balanced) 4 ports 1pps – BNC (unbalanced) 4 ports 1pps – RJ45 (balanced) 4 ports ToD – RJ45

Wander Measurement TIE to ITU-T G.8262, ITU-T O.174

MTIE/TDEV Analysis Built-in wander analysis software with ITU-T Masks (G.813, G.823, G.824, G.8261, G.8262, G.8263, G.8261.1, GR.1244) and Pass/Fail indication (also clock MAFE and clock FFO)

Sync-E Master Accuracy traceable to Reference source (refer Reference Clocks)

Measurement Accuracy 1ns

ESMC (SSM) Features Decode ESMC messages to ITU-T G.8264 and plot Quality Level (QL) changes graphically (bi-directional) to G.8264, G.781 etc. QLs: PRS, PRC, INV3, SSU-A/TNC, INV5, INV6, ST2, SSU-B, INV9, EEC2/ST3, EEC1/SEC, SMC, ST3E, PROV, STU/UKN, DNU/DUS Reference Clocks Lock internal timing reference to external reference. Reference Lock Soft LED indication External reference inputs: 64kHz, 2.048MHz, 6.312MHz,10MHz, T1 BITS clock (1.544Mb/s), E1 MTS (2.048Mb/s), 1pps single ended/differential, Sync-E, GPS Antenna Internal Reference Clock: Frequency Stability over Temp: +/-1.5E-7 (no GPS), <5E-12 over 24hrs (with GPS)

PC Control Interface Any standard PC or laptop (min. 4GB RAM recommended) running Windows XP, Vista or 7 RJ45 LAN connection to instrument

TCP/IP Settings TCP Port, IP Address and Gateway settable

Graph Manipulation Zoom in (X and Y), Zoom out (X and Y), Marker 1, Marker 2, Min/Max display in nanoseconds

Timing Measurements E1, T1, 10MHz, 2.048MHz, Sync-E Wander – TIE, MTIE, TDEV analysis with ITU-T masks, sample rate 0.1Hz to 100Hz(Option 001, 002, 003) 1pps accuracy – recovered slave clock 1pps vs 1pps reference Simultaneous Measurements 4 x Clock Wander (E1/T1/10MHz/2.048MHz) – Option 001 4 x Clock Wander (Sync-E) – Option 002 4 x 1pps Wander/Accuracy – Option 003 4 x ToD Accuracy – Option 003

Remote Control Scripting via TCL Multi-User Architecture

Operation and Regulatory Temperature 5-50˚C, Humidity 0-95%, CE and EMC (incl. EN-61010, EN-61326, etc.) certified Voltage 85-246VAC, 100-240VAC (Nominal) @ 50/60Hz

GPS Rubidium Reference PRS-/Stratum 1 (GPS-locked): typical 1 E-12 (Option 132) Outputs: 10MHz, 1pps

Indicators/LEDs Power On E1, T1, 10MHz, 2MHz, 1pps – Signal Present/Signal Not Present 1GbE, 100BT – Integral LEDs

Clock Reference Output Ports 2 off 10MHz/2.048MHz Reference Outputs (BNC)

1pps + ToD Reference Input 1pps unbalanced Input (BNC), 1pps balanced Input + ToD (RJ48C), ToD/RS-232 (DB9)

1pps + ToD Reference Output 1pps unbalanced Output (BNC), 1pps balanced Output + ToD (RJ48C), ToD/RS-232 (DB9)

ToD 4 ports ToD (CCSA, CISCO, NTP, NMEA format)) – Option 003

Calnex Solutions is a global leader in Test and Measurement solutions for next-generation telecom networks. Our products help to prove new technologies for Mobile Backhaul and Carrier Ethernet networks.

For more information on the Calnex Paragon platform, and to take advantage of Calnex’s extensive experience in Packet Sync and OAM testing technologies, contact Calnex Solutions today:tel: +44 (0) 1506 671 416 email: [email protected]

Specification is subject to change without notice.