Page 1: PARALYMPIC TECHNOLOGY

AUTHORS: Deny Gomes de Freitas, Denize Vilela Novais,

Gina Lizette Anyull Salgado Cubides, Caroline Lopes Gomes de

Abreu, Cleudmar Amaral de Araujo, Sílvio Soares dos Santos.

Page 2: PARALYMPIC TECHNOLOGY

• Improvement of the physical

conditioning

• Technological evolution of

equipment .

(BURTON, 2010)

PURPOSE METHOD CONCLUSION

PARALYMPIC SPORTSRESULTS DISCUSSION MOTIVATION

Page 3: PARALYMPIC TECHNOLOGY

• New ergometers have emerged as

devices for the assessment of paralympic

wheelchair athletes

(FAUPIN, 2008)

PURPOSE METHOD CONCLUSION

ERGOMETERRESULTS DISCUSSION MOTIVATION

Page 4: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSION

INNOVATIONS

RESULTS DISCUSSION MOTIVATION

• Technological innovations in wheelchair ergometers

– Replicate the biomechanical aspects of propulsion in manual wheelchair

– Assessment the physiological response of specific sport paralympic

Page 5: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

Evaluate the power parameters and fatigue

index of paralympic wheelchair athletes using

the Wingate test in a new wheelchair ergometer.

Page 6: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSION

• A new wheelchair ergometer prototype was developed to apply anaerobic tests

• Structural parts were designed with anthropometric measurements and manufactured

in two modules (propulsion and electromagnetic resistance)

RESULTS DISCUSSION MOTIVATION

+−++

=)cos(.)sin(

)sin(

2

..

βαµβαβαµ rP

T

Page 7: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

• LabVIEW program

Page 8: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSION

• A second version the wheelchair ergometer prototype was

developed.

RESULTS DISCUSSION MOTIVATION

Page 9: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

• 12 Paralympic athletes users of wheelchair

– 4 Wheelchair Basketball, 4 swimming, 4 weightlifting

– Gender - 9 males and 3 females;

– Age – 27.9 ± 11.1 years;

– Injury time – 13.5 ± 9.9 years;

– Body mass – 69.0 ± 21 kg.

• Injury of wheelchair athletes: 6 spinal cord injured; 1 poliomyelitis, 1

myelomeningocele, 1 congenital malformation of the lower limb, 1

epiphysiolysis in lower limb, 2 with lower limb ampute.

Page 10: PARALYMPIC TECHNOLOGY

Sample Gender Age (years) Injury Paralympic Sport Injury Time (years) Weight (kg)

1 M 42 Amputee MMII weightlifting 11 58

2 F 23 SCI L4 - L5 weightlifting 9 88

3 M 23 SCI T8 weightlifting 21 77

4 M 32Epiphysiolysis

in lower limbweightlifting 10 103

5 F 27 SCI T10 Swimming 16 42

6 F 50 SCI T5 Swimming 3 57

7 M 19 SCI T11 Swimming 2 61

8 M 27 SCI T3 - T4 Swimming 6 52

9 M 41 Poliomyelitis Wheelchair Basketball 39 110

10 M 19 Myelomeningocele Wheelchair Basketball 19 67

11 M 17Malformation

of the lower limbWheelchair Basketball 17 58

12 M 15 Amputee MMII Wheelchair Basketball 12 56

MOTIVATION PURPOSE METHOD RESULTS DISCUSSION CONCLUSION

Page 11: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

Wingate Test

• Phases

– Heat phase

– Maximum strength (30 seg)

– Recovery phase

• Load

– 7.5% of body mass.

Page 12: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

0

50

100

150

200

250

300

1 2 3 4 5 6 7 8 9 10 11 12

Ab

solu

te P

ow

er

(W)

Paralympic Athlete

weightlifting

Swimming

Wheelchair Basketball

ABSOLUTE POWER

Page 13: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

0

50

100

150

200

250

1

Ab

solu

te P

ow

er(

W)

Powerlifting Swimming Wheelchair Basketball

ABSOLUTE POWER

Page 14: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

ENERGY

140

190

240

290

340

390

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

En

erg

y (

J)

Time (sec)

Page 15: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

0

10

20

30

40

50

60

70

1 2 3 4 5 6 7 8 9 10 11 12

fati

gu

e I

nd

ex

(%

)

Paralympic Athlete

weightlifting

Swimming Wheelchair Basketball

NEW FATIGUE INDEX

Page 16: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSION MOTIVATION

• Studies report factors to be considered:

– Specificity of each paralympic sport

– Gender

– Level of injury

(Devillard, 2001)

Page 17: PARALYMPIC TECHNOLOGY

PURPOSE METHOD CONCLUSIONRESULTS DISCUSSIONMOTIVATION

- Using the new wheelchair ergometer prototype

were found absolute power and a new energy

fatigue index parameters;

- The parameters studied to the sample was

related to functionality, gender, level of injury and

the specific paralympic sports.

Page 18: PARALYMPIC TECHNOLOGY

Acknowledgments

Thank you!