Parker domnick hunter Industrial Gas Generation. “High purity nitrogen gas generated from compressed air”. How much Nitrogen is in air?. Nitrogen - 78% Oxygen - 20.9% Argon - 0.9% CO2 - 0.02% Other “rare” gases make up the balance Hydrogen, neon, helium, krypton and xenon. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Parker  domnick  hunter  Industrial Gas Generation

Parker domnick hunter Industrial Gas Generation

“High purity nitrogen gas generated from compressed air”

Page 2: Parker  domnick  hunter  Industrial Gas Generation

How much Nitrogen is in air?

Nitrogen - 78%

Oxygen - 20.9%

Argon - 0.9%

CO2 - 0.02% Other “rare”

gases make up the

balance Hydrogen, neon, helium, krypton and xenon

ARGONOXYGEN

NITROGEN

Page 3: Parker  domnick  hunter  Industrial Gas Generation

Why do people use Nitrogen?

A clean, dry gas (dewpoint <-70°F)

NITROGEN is an INERT gas that will remove OXYGEN from their product or production processes….

O2N2

Page 4: Parker  domnick  hunter  Industrial Gas Generation

By removing oxygen we can ...

Prevent oxidation of metals, polymers and chemicals

Stop bacteriological growth (foodstuffs & pharmaceuticals)

Reduce the risk of combustion and explosion (chemicals, reactions, processes)

Page 5: Parker  domnick  hunter  Industrial Gas Generation

How is Nitrogen Gas Currently supplied?

Over 90% of nitrogen gas is supplied by 4 large gas companies:-- Praxair- Air Products- Cryoinfra- Air Liquide- BOC Gases

Page 6: Parker  domnick  hunter  Industrial Gas Generation

Gas Supply Options

Cylinder Gas (single and multiple cylinder packs)

Liquid Nitrogen Dewars Bulk Gas Nitrogen Gas Generators

Page 7: Parker  domnick  hunter  Industrial Gas Generation

Disadvantages of Cylinder and Liquid Dewar Supply

Cost High gas cost, rental, delivery,

demurrage charges. Waste - unused gas No control over price increases

from gas company. The most expensive supply method.

Page 8: Parker  domnick  hunter  Industrial Gas Generation

Disadvantages of Cylinder and Liquid Dewar Supply

Safety Dangerous, high pressure gas. Heavy - involve moving and

lifting. Large, stored gas volume

requires special attention (chains and adequate ventilation).

Page 9: Parker  domnick  hunter  Industrial Gas Generation

Safety According to the Dept of environmental safety at

Cornell Univ. Even with the vacuum and insulation, heat leaks in the

cylinder causing the cryogenic liquid to vaporize and build pressure.

The vaporization rate will depend on several factors including the product itself, ambient temperature, condition of the cylinder’s vacuum, etc. The liquid-to-gas conversion rate is about 2.3% per day under perfect conditions, so the actual vaporization rate experienced can vary.

If gas product is not used, pressure will build until it is released by a control valve.

Disadvantages of Cylinder and Liquid Dewar Supply

Page 10: Parker  domnick  hunter  Industrial Gas Generation

Disadvantages of Cylinder and Liquid Dewar Supply

Inconvenience Changing cylinders Inconsistent deliveries Poor gas quality Running out Lost production time

Page 11: Parker  domnick  hunter  Industrial Gas Generation

Bulk Liquid Cryogenic nitrogen

in liquid form Delivered and

stored in large cryogenic tanks (mostly located outside facility)

Capacity of usable gas - can vary

Typical user would require 1200 -10,000 scfh

Page 12: Parker  domnick  hunter  Industrial Gas Generation

Disadvantages of Bulk Liquid

Cost Requires long term, highly restrictive

contracts between gas company and end user

Gas lost / wasted through evaporation 2.3% per day at best

No control over price increases from gas company

Usually requires building permits / license from local authorities

Page 13: Parker  domnick  hunter  Industrial Gas Generation

Disadvantages of Bulk Liquid

Inconvenience Inconsistent deliveries Lack of flexibility - expansion

difficult Running out Lost production time

BACK

Page 14: Parker  domnick  hunter  Industrial Gas Generation

The Alternative:Gas Generation Technologies

Parker domnick hunter Industrial Gas Generation

1) Membrane Generators2) Pressure Swing Adsorption generators

Page 15: Parker  domnick  hunter  Industrial Gas Generation

Parker Hannifin Corporation

Annual sales of $13 billion for fiscal year 2012 (ending June 30, 2012)

world’s leading diversified manufacturer of motion and control technologies and systems

Markets: commercial, mobile, industrial and aerospace

Page 16: Parker  domnick  hunter  Industrial Gas Generation

Organization

82 Combined Divisions (between geographical and functional)

Located in 36 countries around the globe

38 Major brands

Page 17: Parker  domnick  hunter  Industrial Gas Generation

Domnick Hunter Division

Company founded in 1963 Originally a company from the United Kingdom Acquired by Parker Hannifin Corporation in

2006 for close to half billion Dollars Maintains a leadership position in the market

with close to 40% share More than 40 Years experience in Nitrogen

Generation equipment.

Page 18: Parker  domnick  hunter  Industrial Gas Generation

Membrane Generators

“Compressed air is passed through semi-permeable polymer membranes which allow oxygen and water vapor to pass through the polymer and escape to atmosphere, leaving nitrogen as the product gas”

Page 19: Parker  domnick  hunter  Industrial Gas Generation

Membrane Generators

AIR Nitrogen

‘Fast’ water vapor and oxygen molecules diffuse through the membrane polymer.

‘Slow’ nitrogen moleculesstay within and are deliveredas product gas

Page 20: Parker  domnick  hunter  Industrial Gas Generation

Key characteristics - membrane generators

Flow and purity limited typically used for purities of <99.9%

High maintenance cost / activated carbon tower

Less durable to harsh plant conditions

Extremely sensitive to temperature and contamination

Page 21: Parker  domnick  hunter  Industrial Gas Generation

Parker - Domnick Hunter

Pressure Swing Adsorption

(PSA) Generators

Page 22: Parker  domnick  hunter  Industrial Gas Generation

CMS Operating Principles

Pressure swing adsorption using the varying molecular sizes of the gases in ambient air.

Small molecules are trapped in the sieve, nitrogen passes through.

Page 23: Parker  domnick  hunter  Industrial Gas Generation

Pressure Swing Adsorption (PSA)

Generators

“Nitrogen gas is produced by passing ambient air through a proprietary Carbon Molecular Sieve (CMS) which adsorbs O2,H2O,CO2

CMS

Small molecules are trapped in the sieve, nitrogen passes through.

Nitrogen

Inlet air

Oxygen

Page 24: Parker  domnick  hunter  Industrial Gas Generation

CMS

Carbon Molecular Sieve (CMS)

Small oxygen molecules trapped

Larger nitrogen molecules are not

Page 25: Parker  domnick  hunter  Industrial Gas Generation

Key characteristics - PSA generators

Higher Purity Nitrogen - 95% to 99.9995%

Flow 1-10,000 scfh + Low maintenance cost More durable than membrane

technology Less sensitive to temperature

variations than membranes Never have to replace CMS if

maintained properly

Page 26: Parker  domnick  hunter  Industrial Gas Generation

Parker domnick hunter

MAXIGAS PSA Nitrogen Gas

Generators

Page 27: Parker  domnick  hunter  Industrial Gas Generation

Purity of nitrogen gas 95 - 99.9995%

Built-in oxygen analyzer Hour meter PLC Controlled LED displays Simplified wiring Small footprint Expandable design

Parker domnick hunterMAXIGAS

PSA Nitrogen Gas GeneratorsFEATURES

Page 28: Parker  domnick  hunter  Industrial Gas Generation

MAXIGAS Configuration

Light-weight extruded aluminum columns

Bolted construction Alocrom corrosion

protected High quality ASCO

solenoid valves Feet incorporate fork-

lift box design for ease of transport

Page 29: Parker  domnick  hunter  Industrial Gas Generation

N2MAX - MAXIGAS Multi-bank

Add more banks as requirements change

Multi bank to meet your needs 10,000 scfh +

Page 30: Parker  domnick  hunter  Industrial Gas Generation

N2MAX - MAXIGAS Dual-bankN2MAX - MAXIGAS Dual-bank

Simple Electrical Installation

Simple Electrical Installation

Page 31: Parker  domnick  hunter  Industrial Gas Generation

MIDIGASMIDIGAS

Small, self contained PSA system to supply lower gas volumes

Purity of nitrogen gas 95 - 99.999%

Built-in oxygen analyzer

Small footprint Flow rate up to 815

scfh

Small, self contained PSA system to supply lower gas volumes

Purity of nitrogen gas 95 - 99.999%

Built-in oxygen analyzer

Small footprint Flow rate up to 815

scfh

Page 32: Parker  domnick  hunter  Industrial Gas Generation

MAXIGAS systemUse existing compressed air supply or install a dedicated air compressor

PNEUDRI pre-treatment package guarantees clean, dry air to the nitrogen generator

Nitrogen is fed to a buffer vessel

then back from the buffer vessel

Ensuring the nitrogen outlet flow is stable and pulse-free

Air enters the nitrogen generator typically at 6 barg

7 barg

Page 33: Parker  domnick  hunter  Industrial Gas Generation

Typical Installation MAXIGAS DUALBANK Nitrogen

Generator

Air compressor Wet Air Receiver

MAXIGAS Nitrogen Generator

N2 Buffer Vessel

Nitrogen Outlet

NN2

MAXIGAS

Pre-treatment dryer

PNEUDRI

NN2

MAXIGAS

Water Separator

AR filter

Air inlet

Air inlet

PS

Pressure Switch

Pressure switch only required for DME012 to DME040

DME050, 060 and 080 do not require pressure switch

Page 34: Parker  domnick  hunter  Industrial Gas Generation

Benefits of a gas generator

Low cost nitrogen Compact - frees up

valuable floor space

Eliminates safety concerns

Consistent purity No gas waste Expandable No contract

Continuous 24 hour operation Minimal maintenance Control gas supply Fast payback usually <24 months 100% SATISFACTION GUARANTEE!

Page 35: Parker  domnick  hunter  Industrial Gas Generation

Installation Requirements

Well ventilated Protected from water Ambient temperature range

+41 to +113°F

Page 36: Parker  domnick  hunter  Industrial Gas Generation

Air Pre-treatment Package

All systems include integrated compressed air pre-treatment package

PNEUDRI desiccant air dryer c/w filters

Remove contaminants - Oil <0.003mg/m3 - Dewpoint -40°F- Dirt <0.01µ

CMS bed protection GUARANTEED!

Industrial DME dryers

Standard product

Supplied with– AO, AA, AR

filters– Fixing kits

Page 37: Parker  domnick  hunter  Industrial Gas Generation

Annual maintenance

Gas Generator:-- Exhaust silencer (2)

Compressed air dryer:-- 3 Filter elements

CMS never needs to be changed if pre-treatment unit is maintained properly

Page 38: Parker  domnick  hunter  Industrial Gas Generation

Oil Refineries Brazing plants Chemical Plants Controlled Atmosphere Storage Food Processing Plants Heat Treatment Laser Cutting Pharmaceuticals Modified Atmosphere Packaging Gas Assisted Plastic Injection Molding Wineries and Distilleries Electronic Manufacturing plants

Parker – Domnick Hunter MAXIGAS Presence

Page 39: Parker  domnick  hunter  Industrial Gas Generation

Applications OverviewElectronics

Reflow ovens Selective soldering Laser soldering Wave soldering PCB rework Dry boxes Storage of ICs Purging ovens for LCD

manufacture

Page 40: Parker  domnick  hunter  Industrial Gas Generation

Questions

Thank you !!!

Page 41: Parker  domnick  hunter  Industrial Gas Generation

domnick hunter Support

Sergio Castillejos- Regional Sales Mgr Craig Williams- Industrial Nitrogen Sales

Mgr Chad McDaniel- Internal Operations Mgr Nick Herrig- V.P Industrial Sales Mike Troyer - Service & Technical Support