Page 2: Parker P1D Series Actuators

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

SALE CONDITIONSThe items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered into by Parker will be governed by the provisions stated in Parker’s standard terms and conditions of sale (copy available upon request).

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY ANDPROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

NoteAlltechnicaldatainthiscataloguearetypicaldataonly.Airqualityisessentialformaximumcylinderservicelife(seeISO8573).

ImportantBeforeattemptinganyexternalorinternalworkonthecylinderoranyconnectedcomponents,makesurethecylinderisventedanddisconnecttheairsupplyinordertoensureisolationoftheairsupply.

Features Air Hydraulic Electro cylinder cylinder mechanical actuators

Overload safe *** *** *

Easy to limit force *** *** *

Easy to vary speed *** *** *

Speed *** ** **

Reliability *** *** ***

Robustness *** *** *

Installation cost *** * **

Ease of service *** ** *

Safety in damp environments *** *** *

Safety in explosive atmospheres *** *** *

Safety risk with electrical installations *** *** *

Risk of oil leak *** * ***

Clean, hygienic *** ** *

Standardised measurements *** *** *

Service life *** *** *

Hydraulic system required *** * ***

Weight ** ** **

Purchase price *** ** *

Power density ** *** *

Noise level during operation ** *** **

High force for size ** *** *

Positioning possibilities * *** ***

Total energy consumption * ** ***

Service interval * ** ***

Compressor capacity required * *** ***

* = good, **=average, ***=excellent

Page 3: Parker P1D Series Actuators

3

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Contents pageISOcylinderfamily,P1D................................................................................4P1DStandard................................................................................................6P1DClean.....................................................................................................8P1DFlexiblePorting....................................................................................10P1DTie-Rod................................................................................................1�Designvariants........................................................................................13-16Cylinderforces,doubleactingvariants........................................................17Maindata:P1D............................................................................................17Standardstroke...........................................................................................18Operationdata............................................................................................18Workingmedium,airquality........................................................................18Boresandstrokes.........................................................................................18Materialspecification...................................................................................19Cushioningcharacteristics...........................................................................19Guideforselectingsuitabletubing..............................................................�0ValveserieswithrespectiveflowsinNl/minute............................................�1IntroductiontotheATEXdirective................................................................��SafetyinstructionsfortheP1D-Scylinderwithaccessories.........................�4Dimensionsandtolerances.....................................................................�6-�7OrderkeyP1DStandardandP1DTierod..................................................�8OrdercodestandardstrokesP1DStandard................................................�9Orderkeyforcylinderswithfactoryfittedaccessories...........................30-38OrdercodestandardstrokesP1DClean.................................................3941OrderkeyP1DFlexiblePorting....................................................................4�OrdercodestandardstrokesP1DFlexiblePorting.....................................43OrderkeyP1DCleanandP1DFlexiblePorting..........................................44P1Dcompleteworkingunit......................................................................45-47P1Dcylinderwithpistonrodlocking.......................................................48-51P1Dwithrodguidancemodules.............................................................5�-55Cylindermountings.................................................................................56-60Pistonrodmountings...............................................................................61-6�Combinations..........................................................................................63-64Accessories..................................................................................................65Completeworkingunitand3and4positioncylinders................................66Sensors...................................................................................................67-69Connectingcableswithoneconnector........................................................70ConnectionblockValvetronic110................................................................71Pneumaticcylindersensor.....................................................................7�-73P1DSealkits...........................................................................................74-75Orderkey,spareparts..................................................................................76Completeworkingunits–readyforinstallation............................................77ThereisaP1Dcylinderforeveryapplication.........................................78-79MainordercodeP1D..............................................................................80-8�

Page 4: Parker P1D Series Actuators

4

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

ISO cylinder family, P1D Acompletelynewcylinderrangefromthegroundup,withmajorinvestmentinresearch,materialandtech-nology,demandslongexperienceandmajorresources.WhenwedevelopedourP1Dcylinderrange,westartedfromscratch,butnotreally.Decadesofresearchandlearningaboutwhatourcustomersreallyneedworld-widehasgivenusaverystablefoundationtostartfrom.

P1Disacylinderdesignofthehighestpossiblequality,everydetailhasbeenthoughtthrough,without

makinganycompromises.Ithasalargenumberofinnovationswhichcouldonlybeachievedbyusingthebestpossiblematerialsandmethods.TheresultisacompletefamilyofISO/VDMAcylinders,ofwhichweareveryproud.

P1Disahightechnologycylinderdesignforjustabouteveryconceivableapplication,bothsimpleandhighlycomplex.

Page 5: Parker P1D Series Actuators

5

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Thesamehightechnologyplatformisusedforthreemainversions:

• P1D Standard–theuniversal,generalpurposecylinderwithhighperformanceandlonglife.

• P1D Clean–thenewproductlevelforISO/VDMAcylindersofcleandesignwithasystemofintegrated,adjustablesensors(patentappliedfor),forstringenthygienedemands.

• P1D Flexible Porting–theinnovativedesignwhichsavesspaceandreducesdimensionsbyallowingconnectionstobemadeinthefrontorrearendofthecylinder.

• P1D Tie rod–basedonthesamehigh-techdesign,theP1Disalsoavailableinatierodversion.Thisfuture-proofcylinderistheperfectchoicewhereveratierodcylinderisrequired.

Page 6: Parker P1D Series Actuators

6

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Standard TheinnovativeP1Disafuture-proofgenerationofISO/VDMAcylinders.Thecylindersaredouble-acting,withanewdesignofaircushioning.Thelight,stiffbodyextrusionhassensorgroovesforsimpleandprotectedsensorinstallation.

Installation dimensions according to international standardsThenewP1DcomplieswiththecurrentISO6431,ISO1555�,VDMA�456�andAFNORinstallationdimen-sionstandards.Forcustomerreassuranceworld-wide.

High technology design Thebestmaterials,manufacturingmethodsanddesignofeverydetailhavebeencarefullytested,togivethebestpossibleproduct.Theinternalcomponentsaremadeofhighstrengthplastics,forquietoperationandlongservicelife.Thealuminiumendcapsandthetorsionallystiffaluminiumbodyextrusionmakethecylinderrobustandsuitableforawiderangeofapplica-tions.

High quality TheP1Dhasbeendevelopedwithqualityinallphases–requirementspecification,design,planning,purchasing,production,distributionandservice.WehavebeencertifiedundertheISO9001QAstandardforthepasttenyears.Qualityinallourproductsandserv-icesisourwatchword.

Even more functions and variantsTheP1Disavailablewithalltheusualoptionaldesigns,suchas:Throughpistonrod,highandlowtemperature,hydraulicoperation,extendedpistonrodetc.

Anewspecialvariantistheuniqueself-lubricatingHDPEscraperringandpistonrodseal,speciallydesignedforoperationwithacompletelydrypistonrod(i.e.applicationswherethefilmofgreaseonthepistonrodisregularlywashedoff).

Surface treated steel end cover nuts for tough environments. Sealing plugs are available for all P1D cylinders.

All seals are made from polyurethane, which gives P1D cylinders extra long service life.

P1D Standard has a further develop-ment of our famous body extrusion with grooves for the new ”drop-in” sensors.

The cylinder end covers have no cavities or pockets which could collect water or dirt. This facilitates effective cleaning.

The body extrusion is anodised inside and outside, for long life and low friction.

The cylinders have magnetic pistons as standard.

Polyurethane end-of-stroke washers give smooth and quiet operation.

One piston rod nut according to ISO 439B is included as standard.

P1D has a stainless steel piston rod as standard. Hard chromed steel, hard chromed stainless steel and acid-proof steel are available as options.

All P1D cylinders for normal temperature have initial greasing of a transparent, non-toxic grease, approved by the food industry, which is entirely free from PTFE and silicone.

The cushioning has individual flow geom-etry for each cylinder size. This gives effec-tive cushioning which is easier to set and adjust.

Page 7: Parker P1D Series Actuators

7

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Complete accessory programmeP1DoffersacompleteISO,VDMAandAFNORcompa-tibleaccessoryprogramme,withawiderangeofpistonrodandcylindermountingsforbothpivotedandfixedoperation.Severalofthesetypesofmountingsareavail-ableinstainlesssteel.Thenew”drop-in”sensorsareavailablewithbothreedandelectronicoperation,withawidechoiceofconnectortypesandcablelengths.

New, mechanically protected sensor technologyThebodyextrusionhasrecessedsensorgroovesonthreesidesofthecylinder.Thenewsensorsareofthe”drop-in”type,andarequicklyandeasilyinstalledintheT-groovefromtheside.Boththecableandthesensorareprotectedinthegroove.Chooseasensorwith3or10mcable,8mmconnectororthenewM1�connector.

Optimised cushioningThankstotheplasticinsertsintheendcovers,eachcylinderborehasbeengivenindividualflowgeometry.Thisprovidesoptimisedcushioning,whichisquickerandeasiertosetandadjust.

Smooth, quiet operation and long service life Allsealsandend-of-strokewashersaremadefrompoly-urethane(PUR),thebearingsandpistonaremadefromprovenengineeringplasticswithexcellentbearingprop-ertiesandallcylindersaregreasedatthefactorywithatransparent,foodstuffs-approvedgrease.AltogetherthisgivestheP1Dverylongservicelifeandsmooth,quietoperation.

Page 8: Parker P1D Series Actuators

8

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Clean P1DCleanisanewversioninourISOcylindersystem,completelydesignedforthefoodstuffsindustry.Manyyears’experienceofthestringentrequirementsforhygiene,choiceofmaterialandcorrosionresistance,fromawidespectrumoffoodstuffsapplicationshaveguidedthedevelopmentofthiscylinderversion.Greatemphasishasbeenputontheexternaldesignofthecylinder,choiceofmaterialsandcorrosionprotection.

Main dimensions according to international standardsAllthemaindimensionsoftheP1DCleancomplywithISO6431,ISO1555�,VDMA�456�andAFNORstand-ards.Theexceptionisthesomewhatlargerfootprintoftheendcoversandenvelopeofthebodyextrusion,duetotheso-calledpositivegeometry(hygienic,convex,easy-to-cleangeometry)ofthecushioningadjustmentscrewandthecomponentsintheintegratedsensorsystem.

Common, high technology design platformTheP1DCleanhasthesametechnicalplatformastheP1DStandard.Thebestmaterials,includingthepolyurethane(PUR)seals,manufacturingmethodsandthecarefulattentiontodetaildesigngivetheP1DCleansmooth,quietoperationandlongservicelife.

Convex shape for optimum hygiene P1DCleanhasaconvexbodyextrusion,whichmakesthecylinderseasytokeepclean.Irrespectiveofinstalla-tionposition,fluidsrunoffthebodyextrusionsurfaces.

Page 9: Parker P1D Series Actuators

9

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Cushioning screw with positive geometryToofferthebesthygieneproperties,theprojectingcush-ioningscrew,issealedwithrubbersealagainsttheendcover.Thiseliminatesdirt-collectingcavitiesandgivesthebesthygiene,sinceitissoeasytoclean.

Sealing plugs FourplasticsealingplugsaresuppliedwitheveryP1DCleancylinder.Theseareinstalledintheendcoverscrewswhicharenotusedforthecylinderinstallation.Toensurethesealingfunction,theplugscanbeusedonlyoncei.e.theycannotbere-used.Wheninstalledintheendcoverscrews,theyshouldbetappedlightlywithahammertosecurelyfix.

Patent applied system for integrated standard sensorsTheP1DCleancylinderhasasystemofsensors,whicharefullyintegratedintothebodyextrusion,togivethecylindersacleanexternaldesign.UptofoursensorschosenfromtherangeofP1Dstandardsensors,reedorelectronicoperation,canbemountedintwodedicatedgroovesbeneathatransparent,sealedmoulding.Tighteningthestopscrewontothecamshaft,willlockeachsensorinthedesiredposition,withgreatforce.ThesensorLEDsarealwaysfullyvisible,whichfacilitatescommissioning,adjustmentandtrouble-shooting.Theentiresensorsystemhasahose-proofdesign,equiva-lenttoIP65.P1DCleancanbeorderedwithfactory-fittedsensorsintheendpositions,whichcantheneasilybemovedtoanyotherpositionalongtheentirestroke.

Up to four integral sensors Cylindersfortwointegralsensorshavetwoundividedcamshaftsalongtheentirestroke.Freechoiceofcableexit,frontorrear.Thereisalsoaversionwithdividedcamshaftsforuptofoursensors,whichareinstalledtwofromeachendcover,withcableexitfrontandrear.

The sensor position is easily adjusted by undoing a set screw and using the cable to move the sensor to the desired position.

The sensors are mounted into their grooves through the opening in a transparent, sealed cover. The sensor cables have strain relief and are sealed.

Once the sensor has been locked in its new position, the protective cover is installed again.

Simple sensor adjustment

Page 10: Parker P1D Series Actuators

10

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Flexible Porting Progressleadstosmallercomponentsandmachinery.Inharmonywiththistrend,andcomplyingwiththemaindimensionrequirementsinISO6431,wehavedevel-opedP1DFlexiblePorting,whichoffersnew,smarterdesignsolutions.Sinceoneendofthecylindercanbeplacedinrestricted,unusedspaces,withoutneedinganyconnections,thespaceintheapplicationcanbeusedmoreefficiently,ormademorecompact.

Main dimensions according to international standardsApartfromtheprojectingconnectionsonsizesØ3�–63mmP1DFlexiblePortingcomplieswithISO6431,ISO1555�,VDMA�456�andAFNORstandards.

Common, high technology design platformP1DFlexiblePortinghasthesamehightechnologylevelasP1DStandardandP1DClean.Thefuture-proofdesigngivesP1DFlexiblePortinghighperformanceandlongservicelife.

Body extrusion with integrated air channelsP1DFlexiblePortinghasthesamebodyextrusionastheP1DCleancylinder.Sincetheairisledthroughchannelsbuiltintothebodyextrusion,bothconnectionscanbemadetoeitherendofthecylinder.Theflowcapacityoftheairchannelsisbigenoughnottorestrictthecylinderspeedinallnormalapplications.

Page 11: Parker P1D Series Actuators

11

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Straight or elbow push-in fittings for Ø32-63 mm ForcylinderboreØ3�-63mm,oneconnectionislocatedonthebodyextrusion.TheconnectorfromtheModuflexvalverangeisusedforthisconnection.AmatchingPrestolok�(plastic)fittingisusedfortheconnectionattheendcover.Choosebetweenstraightorelbowfittings.Theotherendhasapluginstalledintheunusedcylinderport.

Threaded connections for Ø80-125 mm CylinderboreØ80-1�5mmhavetwothreadedconnec-tionslocatedineitherendcover.Theotherendhasplugsinthecylinderports.Theseplugscanbemovedtotheotherendtosuittheapplication.

Mechanically protected ”drop-in” sensorsThebodyextrusion,whichiscommontoallP1DCleanandP1DFlexiblePortingcylinders,hasrecessedsensorgroovesinthesideopening.Thegeometryhasatthesametimebeendesignedfor”normal”mechanicalsensorinstallation(similartoP1DStandard)andforthebuilt-insensorsystem(P1DClean).Usestandardsensorsintheusualway.

Combine with P1D Clean Forcompactapplicationswithstringenthygienerequirements,P1DCleancanbecombinedwithFlex-iblePorting.Thiscylinderversioncomplieswithmanydifferentrequirementsandoffersnewopportunitiesforcreatingeffectiveapplicationsolutions.

Page 12: Parker P1D Series Actuators

1�

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Tie-Rod TheP1Disavailableinatie-rodversion,basedonthesamehighleveltechnology.Thisfuture-proofcylinderistheperfectchoicewhereveratie-rodcylinderisneeded.

Installation dimensions to international standardTheP1DTie-RodcomplieswithISO6431,ISO1555�,VDMA�456�andAFNORinstallationdimensionstand-ards.Forcustomerreassuranceworld-wide.

Smooth, quiet operation and long service life Allsealsandend-of-strokewashersaremadefrompolyurethane(PUR),thebearingsandpistonaremadefromprovenengineeringplasticswithexcellentbearingpropertiesandtheinitialgreasingatthefactorywithatransparent,foodstuffs-approvedgrease.AltogetherthisgivestheP1Dverylongservicelifeandgentle,quietoperation.

Optimised cushioningThankstotheplasticinsertsintheendcovers,eachcylinderborehasbeengivenanindividualflowgeom-etry.Thisgivesanoptimisedcushioning,whichisquickerandeasiertosetandadjust.

Complete accessory programmeP1DoffersacompleteISO,VDMAandAFNORcompat-ibleaccessoryprogramme,withawiderangeofpistonrodandcylindermountingsforbothpivotedandfixedoperation.

”Drop-in” sensor TheP1DTie-Roduses”drop-in”P1Dsensors.Aningeniousmulti-jointedadapterfixesthesensorsinanychosenpositionalongthestroke.

Page 13: Parker P1D Series Actuators

13

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

UsingP1Dcylindersasaplatform,anumberofdifferentdesignscanbeproducedtosuitdifferingrequirements.Pleaserefertotheorderkeyonpages�8-51forthedesignationofeachvariant.

P1D complete working unitP1DStandardcanbeorderedwithafactory-fittedvalveandpiping.ThevalveseriesistherobustandcompactVikingseries.Ofcourse,theentirerangeofP1DaccessoriescanalsobeusedfortheP1Dwithbuilt-invalve,andcylinderscanbeorderedwithfactory-fittedaccessoriesandsensors.Formoreinformation,seepage45.

P1D cylinder with piston rod lockingTheP1Dcylinderisavailableinaversionwithpistonrodlocking,allowingthepistonrodtobelockedinanyposition.Thelockunit,oftheair/springactuatedtype,isintegratedinthefrontendpieceofthecylinder.Thelockunitcanbeusedforbrakingaswellaslocking.Withnosignalpressure,thefullforceofthelockisappliedtothepistonrod,andthelockisreleasedat4barsignalpressure.LockunitsareavailableforP1DStandard(P1D-L)andP1DClean(P1D-D)indimensionsØ3�-1�5mm.P1DStandardcanbeorderedwithalockunitandabuilt-invalve(P1D-4).Formoreinformation,seepage48

P1D cylinder with internal piston rod threadAllP1Dcylindersareavailablewithaninternalpistonrodthreadwhereashortinstallationlengthisrequired

Design variants for P1D Standard, P1D Clean, P1D Flexible porting and P1D Tie-Rod

P1D-L

P1D-D

Page 14: Parker P1D Series Actuators

14

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Design variants for P1D Standard, P1D Clean, P1D Flexible porting and P1D Tie-Rod

Alternative piston rod materials AllP1Dcylindersinallbores,Ø3�-1�5mm,canbeorderedwiththefollowingpistonrodmaterials:–Steel,hardchromed–Stainlesssteel,rollerpolished(standard)–Acid-proofsteel,rollerpolished–Stainlesssteel,hardchromed

Through piston rod AllP1Dcylindersinallbores,Ø3�-1�5mm,areavailablewithathroughrod.Cylinderswithathroughrodcantakehighersideforcesthankstothedoublesupportforthepistonrod.Inaddition,thisdesignmakesiteasiertoinstallexternalpositionsensors.

Low and high ambient temperature Forallbores,Ø3�-1�5mm,theP1Dcanbesuppliedinspecialhighambienttemperatureandlowambienttemperatureversions.Thecylindershavesealsystems,materialsandgreasefortheirparticulartemperatureranges.Thehightemperatureversiondoesnothavemagneticpiston(nofunc-tionathightemperatures).Thelowtemperaturecylindersdohavemagneticpiston,butrememberthatmostsensorsarespecifiedto–�5°C(nofunctionbelowthistemperature).Ambienttemperatureranges:–Lowtemperature:-40°Cto+40°C–Hightemperature:-10°Cto+150°C,peaksupto+�00°C

Low pressure hydraulicsTheP1DinboresØ3�-1�5mmcanbesuppliedwithspecialsealsforoperationwithlowpressurehydraulicsupto10bar.Temperaturerange-�0°Cto+80°C.

Page 15: Parker P1D Series Actuators

15

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Operation with dry piston rod Inmanyapplications,primarilyinthefoodstuffsindustry,thecylindersarecleanedfrequently.Thismeansthatthefilmofgreaseonthepistonrodiswashedoff,whichputsspecialdemandsonthematerialsandthedesignofthepistonrodsealsystem(scraperringandpistonrodseal).Apistonrodsealsystemspeciallydesignedfordryrodoperationisavail-ableasoptionsforthistypeofapplication,forallboresofP1Dcylinders.ThesystemhasaspeciallydesignedL-shapedsealandthematerialisself-lubricating,highmolecularweightplastics(HDPE)–thesamesystemasinourpreviousP1Ccylinders,withprovenfunction.

P1D with metal scraper ringStandardscraperringscannotbeusedinenvironmentswherethepistonrodmaybecoatedwithresin,ice,cement,sugarcrystals,dough,etc.,primarilyintimberhandling,refriger-ated/chilledtransport,cementindustry,chemicalsandfoodanddrinks.Hardanddirtycoatingsdamagethestandardscraperringsandshortentheirservicelife,introducingdirtintothecylinder.Ascraperringhasbeenspeciallydesignedforapplicationsofthiskind,asanoptionforalldiametersofP1D-S,P1D-TandP1D-Vcylinders.Thescraperring,whichrequiresahard-chromiumplatedpistonrod,hasastainlesssteelcarrier,abrassouterscraperringandanitrilerubberinnerscraperring.

Scraper for high chemical resistanceForuseinapplicationswherechemicalsmayaffectthescraperinthefrontendcover,anoptionwithascraperinFPMrubberforbetterchemicalresistancemustbeused

Design variants for P1D Standard, P1D Clean, P1D Flexible porting and P1D Tie-Rod

Page 16: Parker P1D Series Actuators

16

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Design variants for P1D Standard, P1D Clean, P1D Flexible porting and P1D Tie-Rod

3 and 4 position cylinders Byinstallingtwocylinderswiththesameordifferentstroke,itispossibletobuildaworkingunitwiththreeorfourpositions.Thistypeofunitisavailableasfactory-fittedP1Dtie-rodcylin-ders(P1D-T)inallbores,Ø3�-1�5mm.OtherP1Dcylinderscanbeflangemountedback-to-backwithaspecialmounting(seepages59and66).

Tandem versionTheP1Disalsoavailableasatandemcylinder,i.e.twocylin-dersconnectedinseries.Thiscylinderunithasalmosttwicetheforce,whichisagreatadvantageinrestrictedspaces.Tandemcylindersareavailableastie-rodcylinders,P1D-T,inallboresØ3�-1�5mm.

Page 17: Parker P1D Series Actuators

17

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Main data: P1D Cylinder Cylinder Pistonrod Cushioning Aircon- Connection FlexiblePortingdesignation bore area dia. area thread length sump- thread tubingdimension tion�) Push-in mm cm� mm cm� mm litre mm

P1D-•03�••-XXXX1) 3� 8,0 1� 1,1 M10x1,�5 17 0,105 G1/8 4or6P1D-•040••-XXXX1) 40 1�,6 16 �,0 M1�x1,�5 19 0,16� G1/4 4or6P1D-•050••-XXXX1) 50 19,6 �0 3,1 M16x1,5 �0 0,�53 G1/4 8or10P1D-•063••-XXXX1) 63 31,� �0 3,1 M16x1,5 �3 0,414 G3/8 8or10P1D-•080••-XXXX1) 80 50,3 �5 4,9 M�0x1,5 �3 0,669 G3/8 -P1D-•100••-XXXX1) 100 78,5 �5 4,9 M�0x1,5 �7 1,043 G1/� -P1D-•1�5••-XXXX1) 1�5 1��,7 3� 8,0 M�7x� 30 1,66� G1/�

Total mass including moving parts

Cylinder Totalmass(kg) Supplementmass(kg) Totalmass(kg)designation at0mmstroke forrodlocking Supplementper10mmstroke Standard Tie-Rod Clean/Flex Allvariants Standard Tie-Rod Clean/Flex

P1D-•03�••-X 0,55 0,54 0,60 0,31 0,0�3 0,0�� 0,047P1D-•040••-X 0,80 0,79 0,88 0,44 0,033 0,030 0,063P1D-•050••-X 1,�0 1,�0 1,3� 0,61 0,048 0,048 0,094P1D-•063••-X 1,73 1,73 1,86 1,�5 0,051 0,051 0,101P1D-•080••-X �,45 �,47 �,63 �,45 0,075 0,079 0,14�P1D-•100••-X 4,00 4,00 4,�� 3,7� 0,084 0,084 0,168P1D-•1�5••-X 6,87 6,73 7,01 6,07 0,138 0,1�9 0,�48

Mass moving parts only (for cushioning calculation)

Cylinder Massmovingparts(kg)designation at0mmstroke Supplementper10mmstroke Allvariants Allvariants

P1D-•03�••-X 0,13 0,009P1D-•040••-X 0,�4 0,016P1D-•050••-X 0,4� 0,0�5P1D-•063••-X 0,50 0,0�5P1D-•080••-X 0,90 0,039P1D-•100••-X 1,10 0,039P1D-•1�5••-X �,34 0,0631)Stroke�)Freeairconsumptionper10mmstrokeforadoublestrokeat6bar

Cyl. bore/ Stroke Pistonarea Max theoretical force in N (bar) pist. rod mm cm 2 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0

32/12 + 8,0 80 161 �41 3�� 40� 483 563 643 7�4 804 - 6,9 69 138 �07 �76 346 415 484 553 6�� 691

40/16 + 1�,6 1�6 �51 377 503 6�8 754 880 1005 1131 1�57 - 10,6 106 �1� 318 4�4 530 636 74� 848 954 1060

50/20 + 19,6 196 393 589 785 98� 1178 1374 1571 1767 1963 - 16,5 165 330 495 660 8�5 990 1155 1319 1484 1649

63/20 + 31,� 31� 6�3 935 1�47 1559 1870 �18� �494 �806 3117 - �8,0 �80 561 841 11�1 140� 1682 196� ��4� �5�3 �803

80/25 + 50,3 503 1005 1508 �011 �513 3016 3519 40�1 45�4 50�7 - 45,4 454 907 1361 1814 ��68 2721 3175 36�9 408� 4536

100/25 + 78,5 785 1571 �356 314� 39�7 4712 5498 6�83 7069 7854 - 73,6 736 1473 ��09 �945 368� 4418 5154 5890 66�7 7363

125/32 + 1��,7 1��7 �454 368� 4909 6136 7363 8590 9817 11045 1��7� - 114,7 1147 ��94 3440 4587 5734 6881 80�7 9174 103�1 11468

Note!Selectatheoreticalforce50-100%largerthantheforcerequired

+ =Outwardstroke- = Returnstroke

Cylinder forces, double acting variants

Page 18: Parker P1D Series Actuators

18

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Operation data Workingpressure Max10barWorkingtemperature min maxStandard -�0°C +80°CHightempversion -10°C +150°CLowtempversion -40°C +80°C

Greasedforlife,doesnotnormallyneedadditionallubrication.Ifextralubricationisgiven,thismustalwaysbecontinued.

Bores and strokesP1D 3�-1�5mmStandardstrokes �5-500mmaccordingtoISO4393Maxstroke �800mmMinstroke,P1DClean �5mm(0-�sensors) 100mm(3-4sensors)

P1D CleanProtectionclass Hose-proofinaccordancewithIP65Chemicalresistance Testedfornormallyusedindustrial detergents,bothacidandalkaline

Low pressure hydraulicWorkingpressure Max10bar Min�bar

Forlowpressurehydraulicsystemsisfollowingoilqualitytobeused.

HydraulicoiltypeHLP(DIN515�4,ISO11158).Viscosityby40°C:3�mm�/s(cSt).

ForinstanceShellTellus3�orequal.

Working medium, air quality Workingmedium Dry,filteredcompressedair toISO8573-1class3.4.3.

Recommended air quality for cylinders

Forbestpossibleservicelifeandtrouble-freeoperation,ISO8573-1qualityclass3.4.3shouldbeused.Thismeans5µmfilter(standardfilter)dewpoint+3ºCforindooroperation(alowerdewpointshouldbeselectedforoutdooroperation)andoilconcentration1.0mgoil/m3,whichiswhatastandardcompressorwithastandardfiltergives.

ISO 8573-1 quality classes

Quality Pollution Water Oil class particle max con- max. press. max con- size centration dew point centration (µm) (mg/m³) (°C) (mg/m³)

1 0,1 0,1 -70 0,01 2 1 1 -40 0,1 3 5 5 -�0 1,0 4 15 8 +3 5,0 5 40 10 +7 �5 6 - - +10 -

Standard stroke StandardstrokesforallP1DcylinderscomplywithISO4393.(*40isnotanISOstandardstroke)Specialstrokesupto�800mm.MinimumstrokeforP1DCleanis�5mmwith0-�sensorsand100mmwith3-4sensors.

Order no Cylinder bore = Standard stroke (mm) = Stroke to special order XXXX=Stroke (mm) �5 40 50 80 100 1�5 160 �00 �50 3�0 400 500 600 700 800 �800

Double actingProfile cylinder

P1D-S032MS-XXXX 32P1D-S040MS-XXXX 40P1D-S050MS-XXXX 50P1D-S063MS-XXXX 63P1D-S080MS-XXXX 80P1D-S100MS-XXXX 100P1D-S125MS-XXXX 125

Important!Ifthecylinderisusedinapplicationswithsignificantlateralloadsonthepistonrod,anexternalguidemustbeusedtoachievemaximumservicelife.Seetheexamplesonpages5�-55.

Page 19: Parker P1D Series Actuators

19

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

4,03,0

2,0

1,5

1,0

0,50,4

0,3

0,2

0,11 2 3 4 5 10 20 30 40 50 100 200 300 500 1000 2000

Ø32Ø40 Ø50

Ø63Ø80

Ø100Ø125

Speed [m/s]

Mass [kg]

Material specificationStandard design Bodyextrusion Naturalcolour,anodisedaluminiumEndcover BlackanodisedaluminiumEndcoverinserts POMEndcovernuts/screws Zincplatedsteel8.8Pistonrodnut ZincplatedsteelPistonrod Stainlesssteel,X10CrNiS189Scraperring PURPistonrodbearing POMPiston POMPistonbearing POMMagneticring PlasticboundmagneticmaterialPistonbolt ZincplatedsteelPistonseal PURO-rings Nitrilerubber,NBREnd-of-strokewashers PURCushioningseals PURCushioningscrews LCP

P1D CleanTransparentmoulding SiliconeTransparentcover ABSScrews,sensorsystem Stainlesssteel,A�Uppersealandlowerseal,protectivecover SantoprenSealingplugs PAPistonrodnut Stainlesssteel,A�

P1D Flexible PortingConnectionpartØ3�-63 POMElbowfittingsØ3�-63 PAStraightfittingsonbodyextrusionØ3�-63 PAStraightfittingsinports NickelplatedbrassSeal,connectionpart NitrilerubberNBR

P1D Tie-RodTie-rods Stainlesssteel,X10CrNiS189

Design variantsLowtemperaturedesign Seals/scraperring PolyurethanePUR/NitrilerubberNBR Piston Anodisedaluminium Piston/pistonrodbearing UHMWPEplastic

Hightemperaturedesign Seals/scraperring Fluorocarbonrubber,FPM Piston Anodisedaluminium Piston/pistonrodbearing BronzefilledPTFE

Lowpressurehydraulics Seals/scraperring Nitrilerubber,NBR Piston Anodisedaluminium Piston/pistonrodbearing UHMWPEplastic

CylindersfordryrodoperationSeals/scraperring FPM/HDPE

CylinderwithmetalscraperringScraperring Stainlesssteel/brass/NBR

OptionPistonrodmaterial Hard-chromiumplatedsteel,Fe490-�FN Acid-proofsteel,X5CrNiMo17133 Hard-chromiumplatedstainlesssteel, X10CrNiS189

Cushioning characteristicsThediagrambelowisusedfordimensioningofcylindersrelatedtothecushioningcapacity.Themaximumcushioningcapacityshowninthediagramassumesthefollowing:

•Lowload,i.e.lowpressuredropacrossthepiston•Equilibriumspeed•Correctlyadjustedcushioningscrew•6baratcylinderport

Theloadisthesumofinternalandexternalfriction,plusanygravitationalforces.Athighrelativeload(pressuredropexceeding1bar),werecommendthatforanygivenspeed,themassshouldbereducedbyafactorof�.5,orforagivenmass,thespeedshouldbereducedbyafactorof1.5.Thisisinrelationtothemaximumperformancegiveninthediagram

Page 20: Parker P1D Series Actuators

�0

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Guide for selecting suitable tubingTheselectionofthecorrectsizeoftubingisoftenbasedonexpe-rience,withnogreatthoughttooptimizingenergyefficiencyandcylindervelocity.Thisisusuallyacceptable,butmakingaroughcalculationcanresultinworthwhileeconomicgains.

The following is the basic principle:1.Theprimarylinetotheworkingvalvecouldbeoversized(this

doesnotcauseanyextraairconsumptionandconsequentlydoesnotcreateanyextracostsinoperation).

�.Thetubesbetweenthevalveandthecylindershould,however,beoptimizedaccordingtotheprinciplethataninsufficientborethrottlestheflowandthuslimitsthecylinderspeed,whileanoversizedpipecreatesadeadvolumewhichincreasestheairconsumptionandfillingtime.

Thechartbelowisintendedtohelpwhenselectingthecorrectsizeoftubetousebetweenthevalveandthecylinder.

The following prerequisites apply:Thecylinder load should be about 50%ofthetheoreticalforce(=normalload).Alowerloadgivesahighervelocityandviceversa.Thetubesizeisselectedasafunctionofthecylinder bore,thedesiredcylinder velocityandthetube lengthbetweenthevalveandthecylinder.

Ifyouwanttousethecapacityofthevalvetoitsmaximum,andobtainmaximumspeed,thetubingshouldbechosensothattheyatleastcorrespondwiththeequivalentrestrictiondiameter(seedescriptionbelow),sothatthetubingdoesnotrestrictthetotalflow.Thismeansthatashorttubingmusthaveatleasttheequivalentrestrictiondiameter.Ifthetubingislonger,chooseitfromthetablebelow.Straightfittingsshouldbechosenforhighestflowrates.(Elbowandbanjofittingscauserestriction.)

1) The“equivalentthrottlingbore“isalongthrottle(forexampleatube)oraseriesofthrottles(forexample,throughavalve)convertedtoashortthrottlewhichgivesacorrespondingflowrate.Thisshouldnotbeconfusedwiththe“orifice“whichissometimesspecifiedforvalves.Thevaluefortheorificedoesnotnormallytakeaccountofthefactthatthevalvecontainsanumberofthrottles.

�) Qnisameasureofthevalveflowcapacity,withflowmeasuredinlitreperminute(l/min)at6bar(e)supplypressureand1barpressuredropacrossthevalve.

CylinderØ[mm]

Equivalentthrottlingbore1) TubeØOut./ØInt.[mm]

Lengthoftubing[m]Cylinderspeed[m/s]0,2 0,5 0,8 1,1 1,4 0 1 2 3 4 5 6 7 8 9 10

1

2

3

4

5

6

7

8

9

10

11

Ø10Ø16Ø20Ø25Ø32Ø40Ø50

Ø63

Ø80

Ø100

Ø125

Ø160

Ø200

14/11–/12

–/13

–/14

–/15

–/16

12/10

10/8

8/6

6/45/34/2,7

200

400

800

1000

1200

14001600

1800200022002400

3000

4000

2800

3200340036003800

2600

4

3

2

1

AirflowQn[Nl/min]

Page 21: Parker P1D Series Actuators

�1

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Example 1 : Which tube diameter should be used?A50mmborecylinderistobeoperatedat0.5m/s.Thetubelengthbetweenthevalveandcylinderis�m.Inthediagramwefollowthelinefrom50mmboreto0.5m/sandgetan“equivalentthrottlingbore“ofapproximately4mm.Wecontinueouttotherightinthechartandintersectthelinefora�mtubebetweenthecurvesfor4mm(6/4tube)and6mm(8/6tube).Thismeansthata6/4tubethrottlesthevelocitysomewhat,whilean8/6tubeisalittletoolarge.Weselectthe8/6tubetoobtainfullcylindervelocity.

Example 2 : What cylinder velocity will be obtained?A80mmborecylinderwillbeused,connectedby8m1�/10tubetoavalvewithQn1�00Nl/min.Whatcylindervelocitywillweget?Werefertothediagramandfollowthelinefrom8mmtubelengthuptothecurvefor1�/10tube.Fromthere,wegohorizontallytothecurvefortheØ80cylinder.Wefindthatthevelocitywillbeabout0.5m/s.

Example 3 : What is the minimum inner diameter and maximum lenght of tube?Foraapplicationa1�5mmborecylinderwillbeused.Maximumvelocityofpistonrodis0.5m/s.ThecylinderwillbecontrolledbyavalvewithQn3�00Nl/min.Whatdiameteroftubecanbeusedandwhatismaximumlenghtoftube.Werefertothediagram.WestartattheleftsideofthediagramcylinderØ1�5.Wefollowthelineuntiltheintersectionwiththevelocitylineof0.5m/s.Fromherewedrawahorizontallineinthediagram.Thislineshowsusweneedanequivalentthrot-tlingboreofapproximately10mm.Followingthislinehorizon-tallywecrossafewintersections.Theseintersectionsshowsustheminimuminnerdiameter(rightsidediagram)incombina-tionwiththemaximumlengthoftube(bottomsidediagram).

Forexample:Intersectionone:Whenatube(14/11)willbeused,themaximumlengthoftubeis0.7meter.Intersectiontwo:Whenatube(—/13)willbeused,themaximumlengthoftubeis3.7meter.Intersectionthree:Whenatube(—/14)willbeused,themaximumlengthoftubeis6meter.

Example 4 : Determining tube size and cylinder velocity with a particular cylinder and valve?Foranapplicationusinga40mmborecylinderwithavalvewithQn=800Nl/min.Thedistancebetweenthecylinderandvalvehasbeensetto5m.Tube dimension: Whattubeboreshouldbeselectedtoobtainthemaximumcylindervelocity?Startatpipelength5m,followthelineuptotheintersectionwith800Nl/min.Selectthenextlargesttubediameter,inthiscaseØ10/8mm.Cylinder velocity:Whatmaximumcylindervelocitywillbeobtained?Followthelinefor800Nl/mintotheleftuntilitinter-sectswiththelinefortheØ40mmcylinder.Inthisexample,thespeedisjustabove1.1m/s.

Valve series with respective flows in Nl/minute

Valve series Qn in Nl/Min

ValvetronicSolstar 33InterfacePS1 100AdexA05 173Moduflexsize1,(�x3/�) ��0ValvetronicPVL-B5/3closedcentre,6mmpushin �90Moduflexsize1,(4/�) 3�0B43Manualandmechanical 340ValvetronicPVL-B�x�/3,6mmpushin 350ValvetronicPVL-B5/3closedcentre,G1/8 370CompactIsomaxDX0� 385ValvetronicPVL-B�x3/�G1/8 440ValvetronicPVL-B5/�,6mmpushin 450ValvetronicPVL-B5/3ventedcentre,6mmpushin 450Moduflexsize�,(�x3/�) 450FlowstarP�V-A 5�0ValvetronicPVL-B5/3ventedcentre,G1/8 540ValvetronicPVL-B5/�,G1/8 540ValvetronicPVL-C�x3/�,8mmpushin 540AdexA1� 560ValvetronicPVL-C�x3/�G1/8 570CompactIsomaxDX01 585VIKINGXtremeP�LAX 660ValvetronicPVL-C5/3closedcentre,8mmpushin 700ValvetronicPVL-C5/3ventedcentre,G1/4 700B3-Series 780ValvetronicPVL-C5/3closedcentre,G1/4 780Moduflexsize�,(4/�) 800ValvetronicPVL-C5/�,8mmpushin 840ValvetronicPVL-C5/3ventedcentre,8mmpushin 840ValvetronicPVL-C5/�,G1/4 840FlowstarP�V-B 1090ISOMAXDX1 1150B53Manualandmechanical 1160B4-Series 1170VIKINGXtremeP�LBX 1�90B5-Series,G1/4 1440AirlineIsolatorValveVE��/�3 1470ISOMAXDX� �330VIKINGXtremeP�LCX,G3/8 �460VIKINGXtremeP�LDX,G1/� �660ISOMAXDX3 4050AirlineIsolatorValveVE4�/43 55�0AirlineIsolatorValveVE8�/83 13680

Page 22: Parker P1D Series Actuators

��

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Introduction to the ATEX directiveExplosive atmospheresDirective94/9/ECdefinesanexplosiveatmosphereasamixtureof:

a) flammable substances–gases,vapours,mistsordusts

b) withair

c) underspecificatmospheric conditions

d) inwhich,afterignitionhasoccurred,combustionspreadstotheentireflammablemixture

(NB:withregardtodust,itmaybethatnotalldustiscombustedafterignitionhasoccurred)

Anatmospherewiththepotentialtobecomeanexplosiveatmosphereduringoperatingconditionsand/orundertheinfluenceofthesurroundingsisdefinedasapotentially explosive atmosphere.Productscoveredbydirective94/9/ECaredefinedasintendedforuseinpotentiallyexplosiveatmospheres.

Harmonised European ATEX standard

TheEuropeanUnionhasadoptedtwoharmoniseddirectivesinthefieldofhealthandsafety.ThedirectivesareknownasATEX100aandATEX137.

DirectiveATEX100a(94/9/EC)laysdownminimumsafetyrequirementsforproductsintendedforuseinpotentiallyexplosiveatmospheresinEuropeanUnionmemberstates.DirectiveATEX137(99/9�/EC)definesminimumrequirementsforhealthandsafetyattheworkplace,forworkingconditionsandforthehandlingofproductsandmaterialsinpotentiallyexplosiveatmospheres.Thisdirectivealsodividestheworkplaceintozonesanddefinescriteriabywhichproductsarecategorisedwithinthesezones.Thetablebelowdescribesthezonesinaninstallationwherethereisapotentialforexplosiveatmospheres.Theowneroftheinstallationmustanalyseandassesstheareainwhichtheexplosivegas/dustmixturemayoccur,andifnecessarymustdivideitintozones.Thisprocessofzoningthenallowsthecorrectplantandequipmenttobeselectedforuseinthearea.

TheATEXdirectivehasbeeninforcethroughouttheEuropeanUnionsince1July�003,replacingtheexistingdivergentnationalandEuropeanlegislationrelatingtoexplosiveatmospheres.Pleasenotethatforthefirsttime,thedirectivecoversmechanical,hydraulicandpneumaticequipmentandnotjustelectricalequipmentasbefore.

WithregardtotheMachinery directive98/37/EC,notethatanumberofexternalrequirementsin94/9/ECrefertohazardsarisingfrompotentiallyexplosiveatmospheres,wheretheMachinerydirectiveonlycontainsgeneralrequirementsrelatingtoexplosionsafety(AnnexI1.5.7).Asaresult,directive94/9/EC(ATEX100a)takesprecedenceovertheMachinerydirectivewithregardtoexplosionprotectioninpotentiallyexplosiveatmospheres.TherequirementsintheMachinerydirectiveareapplicabletoallotherrisksrelatingtomachinery.

Zones Presence of potentially explosive atmosphere Type of risk Gas Dust G D

0 �0 Presentcontinuouslyorforlongperiods Permanent

1 �1 Likelytooccurinnormaloperationoccasionally Potential

� �� Notlikelytooccurinnormaloperationbut,ifitdoesoccur, Minimal willpersistforashortperiodonly

Zone1Category�

Zone�Category3

Zone0Category1

Page 23: Parker P1D Series Actuators

�3

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Levels of protection for the various equipment categories

Thevariousequipmentcategoriesmustbecapableofoperatinginaccordancewiththemanufacturer’soperatingspecificationsatdefinedlevelsofprotection.

Level of Category Type of protection Operating specifications protec- Group Group tion I II

Very M1 Twoindependentmeansofprotectionorsafety,ensuringthat Theequipmentremainsenergisedand high theequipmentremainsfunctionalevenintheeventoftwofaults andfunctionalevenwithanexplosive occurringindependentlyofeachother atmospherepresent

Very 1 Twoindependentmeansofprotectionorsafety,ensuringthat Theequipmentremainsenergisedand high theequipmentremainsfunctionalevenintheeventoftwofaults functionalinzones0,1,�(G)and/or occurringindependentlyofeachother zones�0,�1,��(D) High M� Protectionsuitablefornormaloperationandsevere Theequipmentisde-energisedinthe operatingconditions eventofanexplosiveatmosphere High � Protectionsuitablefornormaloperationandfrequentfaults,or Theequipmentremainsenergisedandfunc- equipmentinwhichfaultsnormallyhavetobetakenintoaccounttionalinzones1,�(G)and/orzones�1,��(D) Normal 3 Protectionsuitablefornormaloperation Theequipmentremainsenergisedandfunc- tionalinzones�(G)and/orzones��(D)

G=gasandD=dust

Temperature classes

Classificationofflammablegasesandvapoursonthebasisofignitiontemperature

Group I II mines, combustible vapours other potentially explosive atmospheres (gases, dust)

Category M1 M2 1 2 3

Atmosphere* G D G D G D

Zone 0 �0 1 �1 � ��

Declaration of conformity

Theproductcataloguescontaincopiesofthedeclarationofconformitydemonstratingthattheproductmeetstherequirementsofdirective94/9/EC.Thedeclarationisonlyvalidinconjunctionwiththeinstructionscontainedintheinstallationmanualrelatingtothesafeuseoftheproductthroughoutitsservicelife.Theinstructionsrelatingtotheconditionsinthesurroundingareaareparticularlyimportant,asthecertificateisinvalidatediftheinstructionsarefoundnottohavebeenadheredtoduringoperationoftheproduct.Ifthereisanydoubtastothevalidityofthecertificateofconformity,contactParkerHannifincustomerservice.

Temperature class Ignition temperature °C

T1 Over450

T� (300)–450

T3 (�00)–300

T4 (135)–�00

T5 (100)–135

T6 (85)-100

Operation, installation and maintenance

Theinstallationmanualoftheproductcontainsinstructionsrelatingtothesafestorage,handling,operationandservicingoftheproduct.Themanualisavailableindifferentlanguages,andcanbedownloadedfromwww.parker.com/euro_pneumatic.Thisdocumentmustbemadeaccessibleinasuitableplacenearwheretheproductisinstalled.Itisusedasareferenceforallpersonnelauthorisedtoworkwiththeproductthroughoutitsservicelife.We,themanufacturer,reservetherighttomodify,extendorimprovetheinstallationmanualintheinterestsoftheusers.

FormoreinformationaboutATEXseeEUshomepage:http://europa.eu.int/comm/enterprise/atex/

Definition of groups(EN11�7-1)Group I Equipmentintendedforuseinundergroundpartsofminesaswellasthosepartsofsurfaceinstallationsofsuchmineslikelytobe

endangeredbyflammablevapoursand/orflammabledusts.Group IIEquipmentintendedforuseinotherplacesexposedtoexplosiveatmospheres.

Page 24: Parker P1D Series Actuators

�4

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Supplementary safety instructions for P1D-S cylinders installed in Ex-areasSerious, even fatal, damage or injury may be caused by the hot moving parts of the P1D cylinders in the presence of explosive gas mixtures and concentrations of dust.

Allinstallation,connection,commissioning,servicingandrepairworkonP1Dcylindersmustbecarriedoutbyqualifiedpersonneltakingaccountofthefollowing•Theseinstructions

•Markingsonthecylinder

•Allotherplanningdocuments,commissioninginstructionsandconnectiondiagramsassociatedwiththeapplication.

•Provisionsandrequirementsspecifictotheapplication

•National/internationalregulations(explosionprotection,safetyandaccidentprevention)

Real life applications

P1Dcylindersaredesignedtoprovidelinearmovementinindustrialapplications,andshouldonlybeusedinaccordancewiththeinstructionsinthetechnicalspecificationsinthecatalogue,andwithintheoperatingrangeindicatedontheratingplate.Thecylindersmeettheapplicablestandardsandrequirementsofdirective94/9/EC(ATEX)

Thecylindersmustnotbeusedundergroundinminessusceptibletofiredampand/orflammabledusts.Thecylindersareintendedforuseinareasinwhichexplosiveatmospherescausedbygases,vapoursormistsofflammableliquids,orair/dustmixturesmaybeexpectedtooccurduringnormaluse(infrequently)

Checklist

BeforeusingthecylindersinanEx-area,youshouldcheckthefollowing:DothespecificationsoftheP1D-ScylindermatchtheEx-classificationoftheareaofuseinaccordancewithdirective94/9/EC(previouslyATEX100a)•Equipmentgroup

•Ex-equipmentcategory

•Ex-zone

•Temperatureclass

•Max.surfacetemperature

1.WheninstallingtheP1D-Scylinder,isitcertainthatthereisnopotentiallyexplosiveatmosphere,oil,acids,gases,vapoursorradiation?

�.Istheambienttemperatureasspecifiedinthetechnicaldatainthecatalogueatalltimes?

3.IsitcertainthattheP1D-Scylinderisadequatelyventilatedandthatnoforbiddenadditionalheatisadded?

4.AreallthedrivenmechanicalcomponentsATEXcertified?

5.CheckthattheP1D-Scylinderissafelyearthed.

6.CheckthattheP1D-Scylinderissuppliedwithcompressedair.Explosivegasmixturesmustnotbeusedfordrivingthecylinder.

7.CheckthattheP1D-Scylinderisnotequippedwithametalscraperring(specialversion).

Installation requirements in Ex-areas

• Thetemperatureofthesupplyairmustnotexceedtheambienttemperature.

• TheP1D-Scylindermaybeinstalledinanyposition.

• AnairtreatmentunitmustbeattachedtotheinletoftheP1D-Scylinder.

• TheP1D-Scylindermustbeconnectedtoearthatalltimes,throughitssupport,ametallictubeorseparateconductor.

• TheoutletoftheP1D-ScylindermustnotbeopenwithinanEx-area,butmustbeconnectedtothesilenceror,preferably,pipedandreleasedoutsidetheEx-area.

• TheP1D-ScylindermayonlydriveunitsthatareATEXcertified.

• EnsurethattheP1D-Scylinderisnotexposedtoforcesgreaterthanthosepermittedinaccordancewiththecatalogue

• TheP1D-Scylindermustbesuppliedwithcompressedair.Explosivegasmixturesmustnotbeused

• P1D-ScylinderswithmetalscraperringsmustnotbeusedinEx-areas

Inspecting cylinders during operationTheP1Dcylindermustbekeptcleanontheoutside,andalayerofdust/dirtthickerthan1mmmustneverbeallowedtoform.Strongsolventsshouldnotbeusedforcleaning,becausetheycancausetheseal(materialPUR)aroundthepistonrodtoswell,potentiallyincreasingthetemperature.Inspectandverifythatthecylinder,withattachments,compressedairfittings,hoses,tubes,etc.meetthestandardsof”safe”installation.

Marking of cylinder P1D-S Standard (P1D-S***MS-****)

CommunautéEuropéenne=EUCEontheproductshowsthatParkerHannifinproductsmeetoneormoreEUdirectives.

Exmeansthatthisproductisintendedforuseinpotentiallyexplosiveatmospheres.

II Standsfortheequipmentgroup(I=minesandII=otherhazardousareas).

2GD Standsforequipmentcategory�Gmeanstheequipmentcanbeusedinzones1and�wherethereisariskinvolvinggases,vapoursormistsofcombustibleliquidsand�Dinzones�1and��wherethereisariskinvolvingdusts.�GDMeanstheequipmentcanbeusedinzones1,�,�1and��.

c Safedesign(prEN13463-5)

T4 IfequipmentisintemperatureclassT4,themaximumsurfacetemperaturemustnotexceed135°C.(Toguaranteethis,theproducthasbeentestedtoensurethatthemaximumis130°C.Thisprovidesasafetymarginof5°K).

120 °C MaximumpermittedsurfacetemperatureonP1D-Scylinderinatmospherescontainingpotentiallyexplosivedusts.

Safety instructions for the P1D-S cylinder with accessories

II 2GD c T4 120 °C

Page 25: Parker P1D Series Actuators

�5

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Supplementary safety instructions for P8S- GPFLX/EX sensors installed in Ex-areasSerious, even fatal, damage or injury may be caused by the hot moving parts of the P1D cylinders in the presence of explosive gas mixtures and concentrations of dust.

Instructions for use

Safety instructions

• CylindersensorATEXclassedforcategoryII3GandII3D

• AmbienttemperatureTa=-�0°Cto+45°C

• TemperatureclassT4,ormax.surfacetemperatureofT=135°C

• ProtectionclassIP67

• Readinstallationinstructionsbeforestartup

• Installation,connectionandcommissioningmustbecarriedoutbytrainedpersonnel

Applications

• ThissensorisdesignedforuseintheT-grooveofcylinders,anddetectsthemagneticfieldinpotentiallyexplosiveareas.ThesensorcanonlybeinstalledintheT-grooveofthesecylinders.

• Thesensormayalsobeinstalledonroundcylindersbymeansofthefollowingattachments:

P8S-TMC01SuitableforP1SandP1Adiameter10-�5mm

P8S-TMC02SuitableforP1Sdiameter3�-63mm

P8S-TMC03SuitableforP1Sdiameter80-1�5mm

Thefollowingdataappliestotheseattachments:

- AmbienttemperatureTa=0°Cto45°C

- LowenergyabsorptiontoEN500�1

• Thesensormayalsobeinstalledontie-rodcylindersorprofilecylindersbymeansofthisattachment:

P8S-TMA0XSuitableforP1D-Tdiameter3�-1�5mm,P1E-Tdiameter160–�00mmandC41diameter160–�00mm

Installation

General:ThesensormustbeprotectedfromUVradiation.Thecablemustbeinstalledsuchthatitisprotectedfromexternalinfluences,forexampleitmaybenecessarytoattachanexternalstrainrelieftothecable.

Technical data for sensor

OperatingvoltageUb=18to30VDCMax.loadcurrentIad”¡Ü70mAAmbienttemperature:-�0°Cto45°C

Commissioning

Whenconnectingthesensortoapowersource,pleasepayattentiontothefollowinga)theloaddata(operatingvoltage,continuousloadcurrent)b)thewiringdiagramforthesensor

Maintenance

OurP8S-GPFLX/EXcylindersensorismaintenancefree,butthecableconnectionsshouldbecheckedatregularintervals.ThesensormustbeprotectedfromUVradiation.Thesensormustbekeptcleanontheoutside,andalayerofdirtthickerthan1mmmustneverbeallowedtoform.Strongsolventsshouldnotbeusedforcleaningastheymaydamagethesensor.

P8S-GPFLX/EX cylinder sensor

CommunatutéEuropéenne=EU

CEontheproductshowsthatParkerHannifinproductsmeetoneormoreEUdirectives.

Exmeansthatthisproductisintendedforuseinpotentiallyexplosiveatmospheres.

II Standsfortheequipmentgroup(I=minesandII=otherhazardousareas)

3G Standsfortheequipmentcategory3Gmeanstheequipmentcanbeusedinzone�wherethereisariskinvolvinggases,vapoursormistsofcombustibleliquids.

EEx EExmeansthatthisisanelectricalproductintendedforuseinEx-areas.

nA II nNotignitabletoEN500�1,AExplosiongrouptestedwithacetone,ethanol,tolueneandxylene;IINotforuseintheminingindustry.

T4 X IfequipmentisintemperatureclassT4,themaximumsurfacetemperaturemustnotexceed135°C.(Toguaranteethis,theproducthasbeentestedtoensurethatthemaximumis130°C.Thisprovidesasafetymarginof5°K.)XMustbeinstalledinaccordancewiththeinstallationmanual.

3D Standsforequipmentcategory3Dinzone��wherethereisariskinvolvingdusts.

135 °CMaximumpermittedsurfacetemperatureonthesensorinatmospherescontainingpotentiallyexplosivedusts.

IP67 SatisfiesprotectionclassIP67.

Components such as cylinder attachments, tube fittings, tubes, etc.Components

ParkerHannifinguaranteesthatourcylinderattachments,tubefittings,tubes,etc.arenotsubjecttotheprovisionsoftheATEXdirective.

Acomponentmeansanyitemessentialtothesafefunctioningofequipmentandprotectivesystemsbutwithnoautonomousfunction.

ComponentsintendedforincorporationintoequipmentorprotectivesystemswhichareaccompaniedbyanattestationofconformitywiththeATEXdirective,includingastatementoftheircharacteristicsandhowtheymustbeincorporatedintoproducts,areconsideredtoconformtotheapplicableprovisionsofdirective94/9/EC.Ex-componentsasdefinedintheEuropeanstandardEN50014arecomponentsinthesenseoftheATEXdirective94/9/ECaswell.ComponentsmustnothavetheCEmarkingaffixedunlessotherwiserequiredbyotherdirectives.

Examplesofcomponents:

• terminals

• pushbuttonsassemblies

• relays

• emptyflameproofenclosures

• ballastsforfluorescentlamps

• meters(e.g.movingcoil)

• encapsulatedrelaysandcontactors,withterminalsand/orflyingleads

II3G EEx nA II T4X II3D 135 °C IP67

Page 26: Parker P1D Series Actuators

�6

08.01

www.parker.com/euro_pneumatic

DimensionsCylinderbore AM B BA BG D D4 E EE G KK L� L8 L9 L1�mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� �� 30 30 16 1� 45,0 50,0 G1/8 �8,5 M10x1,�5 16,0 94 146 6,0 40 �4 35 35 16 16 5�,0 57,4 G1/4 33,0 M1�x1,�5 19,0 105 165 6,5 50 3� 40 40 16 �0 60,7 69,4 G1/4 33,5 M16x1,5 �4,0 106 180 8,0 63 3� 45 45 16 �0 71,5 8�,4 G3/8 39,5 M16x1,5 �4,0 1�1 195 8,0 80 40 45 45 17 �5 86,7 99,4 G3/8 39,5 M�0x1,5 30,0 1�8 ��0 10,0100 40 55 55 17 �5 106,7 116,0 G1/� 44,5 M�0x1,5 3�,4 138 �40 14,01�5 54 60 60 �0 3� 134,0 139,0 G1/� 51,0 M�7x� 45,0 160 �90 18,0

Cylinderbore PL PP R RT SS SW TT VA VD WH WL WTmm mm mm mm mm mm mm mm mm mm mm

3� 13,0 �1,8 3�,5 M6 4,0 10 4,5 3,5 4,5 �6 �1 M8x1 40 14,0 �1,9 38,0 M6 8,0 13 5,5 3,5 4,5 30 �3 M10x1,�5 50 14,0 �3,0 46,5 M8 4,0 17 7,5 3,5 5,0 37 31 M14x1,5 63 16,4 �7,4 56,5 M8 6,5 17 11,0 3,5 5,0 37 31 M14x1,5 80 16,0 30,5 7�,0 M10 0 �� 15,0 3,5 4,0 46 39 M18x1,5100 18,0 35,8 89,0 M10 0 �� �0,0 3,5 4,0 51 39 M18x1,51�5 �8,0 40,5 110,0 M1� 0 �7 17,5 5,5 6,0 65 53 M�4x�S=Stroke

TolerancesCylinderbore B BA L8 L9 R Stroketolerance Stroketolerancemm mm mm mm uptostroke500mm forstrokeover500mm

3� d11 d11 ±0,4 ±� ±0,5 +0,3/+�,0 +0,3/+3,0 40 d11 d11 ±0,7 ±� ±0,5 +0,3/+�,0 +0,3/+3,0 50 d11 d11 ±0,7 ±� ±0,6 +0,3/+�,0 +0,3/+3,0 63 d11 d11 ±0,8 ±� ±0,7 +0,3/+�,0 +0,3/+3,0 80 d11 d11 ±0,8 ±3 ±0,7 +0,3/+�,0 +0,3/+3,0100 d11 d11 ±1,0 ±3 ±0,7 +0,3/+�,0 +0,3/+3,01�5 d11 d11 ±1,0 ±3 ±1,1 +0,3/+�,0 +0,3/+3,0

P1D Standardcylinder

AM

ØB

ØD

KK

WT

BG

VD

G

WH

WH

WH

WL

WH + S

L2

L12

ØD

4

PP

PL

SS

TT Ø

BA

VA

GL8 + S

RT

R

E

L9 + 2 x S

DIN 439B

SW

EE

P1D Standard CAD drawings on the InternetOurhomepagewww.parker.com/euro_pneumaticincludestheAirCadDrawingLibrarywith�Dand3Ddrawingsforthemainversions.

Internal piston rod thread

Page 27: Parker P1D Series Actuators

�7

08.01

www.parker.com/euro_pneumatic

AM

ØB

ØD

KK

VD

G

349 18

3

WH

L2

L12

PPE2 maxPL

SS

TT Ø

BA

VA

GL8 + S

RT

R

E

E 1

DIN 439B

SW

EE

ØD

7

AM

ØB

ØD

KK

VD

G

WH

L2

L12

ØD

7

PP

PL

SS

TT Ø

BA

VA

GL8 + S

RT

R

E

E3

DIN 439B

SW

EE

AM

ØB

ØD

KK

VD

G

WH

L2

L12

ØD

5

ØD

6

PP

PL

SS

TT Ø

BA

VAG

L8 + S

RT

R

E

DIN 439B

SW

EE

DimensionsCylinderbore Elbowfittings,tubingØmm Straightfittings,tubingØmm 4 6 8 10 4 6 8 10 D5 D6 D7 E1 E�max E3 E3 E3 E3 E3 E3 E3 E3mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 36 5,3 49,6 3� 30,0 4� 44 - - 38 40 - - 40 44 5,3 57,3 36 34,7 46 48 - - 4� 44 - - 50 55 7,1 69,3 4� 40,7 - - 56 76 - - 48 50 63 68 7,1 8�,3 49 46,� - - 64 83 - - 55 75 80 86 8,9 99,3 57 54,7 - - - - - - - -100 106 8,9 117,6 68 64,0 - - - - - - - -1�5 13� 10,8 14�,8 81 75,5 - - - - - - - -

Otherdimensions,seeoppositepageP1DFlexiblePortingØ80-Ø1�5canbeorderedwiththreadedportsonlyorwithfactory-fittedelboworstraightpush-infittings(seeposition�0intheordercodekeypage3�)

P1D Clean

P1D Tie-Rod

P1D Flexible Porting

P1D Clean/Tie-Rod/FlexiblePorting

MinimumstrokeforP1DCleanis�5mmwith0-�sensorsand100mmwith3-4sensors.

Page 28: Parker P1D Series Actuators

�8

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

The simple and complete order keyTheP1Dorderkeyisbasedonthesameprinciplesasitspredecessors,theP1CandP1E.Thismakesiteasytoidentifyandorderallcommoncylinderversions.Thechange-overfromourpreviouscylinderrangestotheequivalentP1Dcylindersislogicalandsimple.Asfaraspossible,thesamesymbolsasforP1CandP1Ehavebeenretainedforthesamefunctions.MostofthecommoncylindertypesintheP1D-familyhavea15-digitordernumber.

Manyofournewcylinderversions,e.g.P1DCleanandP1DFlexiblePorting,andcompleteworkingunits(withfactory-fittedcylindermountings,sensorsetc.)aredefinedbya�0-digitordernumber.ThereisonlyonesingleorderkeyforP1D,whichthuscontainsthe15-digitordernumbersforthemostcommoncylindertypesand�0-digitordernumbersforcylinderswithmorefunctions.Rememberthattherearealways15or�0positionsintheordernumber–neveranyfigureinbetween.

Example 1 Standard, double acting cylinder Standardcylinderwithstandardscraperring(PUR),standardpistonrodmaterial(stainlesssteel)andstandardtemperaturerange.

P1D Compare P1C and P1E

P1D-S03�MS-0160 P1C-S03�MS-0160 P1E-S03�MS-0160P1D-S100MS-0400 P1C-S100MS-0400 P1E-S100MS-0400

Example 2 Tie-Rod design, double acting cylinder Tie-rodcylinderwithstandardscraperring(PUR),hardchromedsteelpistonrodandstandardtemperaturerange.

P1D Compare P1E

P1D-T040MC-01�5 P1E-T040MC-01�5

�) P1DCleanwithoutsensorfunction,seepage41.6) ForP1D-SandP1D-T.��)Ifstainlesssteelendcoverscrewsareselected,thepistonrodnutsarealsosuppliedinstainlesssteel.�3)Fordryrodoperation.�4)Thesealsystemforlowpressurehydraulicsdemandsahardchromedsurfaceforproperfunction.�5)Themetalscraperringrequiresahard-chromiumplatedpistonrod�6) FPMscrapershouldbechosenforhigherchemicalresistanceonstandardtemperatureversionsonly.

Cylinder bore mm

032

040

050

063

080

100

125

Stroke (mm) e.g. 0100 = 100 mm

Optionalstrokelengthsupto�800mm.Standardstrokesseetablepage18

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 3 2 M S – 0 1 0 0

Piston rod Seals material

S C M R Standard-�0°Cto+80°C.

F G N D Hightemperatureversion6) -10°Cto+150°C. Nomagneticfunction

L K P E Lowtemperatureversion6) -40°Cto+40°C.

– J – Z Lowpressurehydraulic6)�4)

Stai

nles

sst

eel

Chr

omiu

m-p

late

dst

eel

Aci

d-pr

oofs

teel

Chr

om.-p

l.st

ainl

ess

stee

l

Cylinder version

S Standard

C Clean�)

F FlexiblePorting

T Tie-Rod

II 2GD c T4 120 °C

ValidforP1D-S***MS-****,seeATEXinformationpages��-�5.

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

2 4 6 8 – – – – 3and4positioncylinders

C J K L – – – – Tandem

Page 29: Parker P1D Series Actuators

�9

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D StandardDouble-acting

Cyl. bore Stroke Order codemm mm

32 �5 P1D-S032MS-0025Conn.G1/8 40 P1D-S032MS-0040 50 P1D-S032MS-0050 80 P1D-S032MS-0080 100 P1D-S032MS-0100 1�5 P1D-S032MS-0125 160 P1D-S032MS-0160 �00 P1D-S032MS-0200 �50 P1D-S032MS-0250 3�0 P1D-S032MS-0320 400 P1D-S032MS-0400 500 P1D-S032MS-0500

40 �5 P1D-S040MS-0025Conn.G1/4 40 P1D-S040MS-0040 50 P1D-S040MS-0050 80 P1D-S040MS-0080 100 P1D-S040MS-0100 1�5 P1D-S040MS-0125 160 P1D-S040MS-0160 �00 P1D-S040MS-0200 �50 P1D-S040MS-0250 3�0 P1D-S040MS-0320 400 P1D-S040MS-0400 500 P1D-S040MS-0500

50 �5 P1D-S050MS-0025Conn.G1/4 40 P1D-S050MS-0040 50 P1D-S050MS-0050 80 P1D-S050MS-0080 100 P1D-S050MS-0100 1�5 P1D-S050MS-0125 160 P1D-S050MS-0160 �00 P1D-S050MS-0200 �50 P1D-S050MS-0250 3�0 P1D-S050MS-0320 400 P1D-S050MS-0400 500 P1D-S050MS-0500

63 �5 P1D-S063MS-0025Conn.G3/8 40 P1D-S063MS-0040 50 P1D-S063MS-0050 80 P1D-S063MS-0080 100 P1D-S063MS-0100 1�5 P1D-S063MS-0125 160 P1D-S063MS-0160 �00 P1D-S063MS-0200 �50 P1D-S063MS-0250 3�0 P1D-S063MS-0320 400 P1D-S063MS-0400 500 P1D-S063MS-0500

P1D StandardDouble-acting

Cyl.bore Stroke Ordercodemm mm

80 �5 P1D-S080MS-0025Conn.G3/8 40 P1D-S080MS-0040 50 P1D-S080MS-0050 80 P1D-S080MS-0080 100 P1D-S080MS-0100 1�5 P1D-S080MS-0125 160 P1D-S080MS-0160 �00 P1D-S080MS-0200 �50 P1D-S080MS-0250 3�0 P1D-S080MS-0320 400 P1D-S080MS-0400 500 P1D-S080MS-0500

100 �5 P1D-S100MS-0025Conn.G1/� 40 P1D-S100MS-0040 50 P1D-S100MS-0050 80 P1D-S100MS-0080 100 P1D-S100MS-0100 1�5 P1D-S100MS-0125 160 P1D-S100MS-0160 �00 P1D-S100MS-0200 �50 P1D-S100MS-0250 3�0 P1D-S100MS-0320 400 P1D-S100MS-0400 500 P1D-S100MS-0500

125 �5 P1D-S125MS-0025Conn.G1/� 40 P1D-S125MS-0040 50 P1D-S125MS-0050 80 P1D-S125MS-0080 100 P1D-S125MS-0100 1�5 P1D-S125MS-0125 160 P1D-S125MS-0160 �00 P1D-S125MS-0200 �50 P1D-S125MS-0250 3�0 P1D-S125MS-0320 400 P1D-S125MS-0400 500 P1D-S125MS-0500

Thecylindersaresuppliedcompletewithonezincplatedsteelpistonrodnut.

P1D StandardTheordernumbersonthispagerefertoP1DStandardwithoutsensors.Thecylinderscanbeorderedwithsensors,fittings,pistonrodandcylindermountings,speedcontrolsetc.foreffi-cientlogistics.Pleaserefertotheorderkeytoselectcylinderswithfactory-fittedaccessories.

II 2GD c T4 120 °C

SeeATEXinformationpages��-�5.

Page 30: Parker P1D Series Actuators

30

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Usingthe�0-digitordernumber,itispossibletoordercompleteworkingunitswithfactoryinstalledpistonrodsandcylindermountings,sensorsetc.

Pistonrodmountingsandsealingplugsforthecylinderendcoverscrewsarespecifiedinposition16inaccordancewiththeorderkeybelow.

8) Validonlyforcylinderswithfactory-fittedcylindermountings.P1DCleancylindersarealwaysdeliveredwith4sealingplugs.9) P1Dcylindersarealwaysdeliveredwithonepistonrodnutinzinc-platedsteel,exceptP1DCleanwhichisdeliveredwiththepistonrodnut

instainlesssteel.CodesXandPmeanthatthecylinderisdeliveredwithoneadditionalnutofthesametype.10)Thepistonrodnutinzinc-platedsteelisreplacedbyanutinstainlesssteel

(P1DCleanisalwaysdeliveredwithonepistonrodnutinstainlesssteel).18)Onlyforbore3�-100mm

Example of piston rod fittings and end cover screw sealing plugsP1D-S040MS-03�0CNNNN P1DStandardwithazincplatedclevisonthepistonrodandwithoutsealingplugsintheendcoverscrewsP1D-S080MS-0�50ATNNN P1DStandardwithswivelrodeyeonthepistonrod,clevisbracketMP�installedonrearendcoverand sealingplugsinthecylinderendcoverscrewsinthefrontend.

Pleasenotethatanordercodewithsealingplugsmustbecombinedwithselectingacylindermountinginposition17.Thesealingplugsareinstalledintheendcoverscrewswhicharenotused.

P1D cylinders with piston rod mountings and end cover screw sealing plugs

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – S 0 4 0 M S – 0 3 2 0 C N N N N

Factory-fitted piston rod mountings and sealing plugs

S A Swivelrodeye,zinc-platedsteel

T 1 Swivelrodeye,stainlesssteel10)

V E Swivelrodeye,zinc-platedsteelandclevisbracketGA

W 2 Swivelrodeye,stainlesssteelandclevisbracketGA10)

C B Clevis,zinc-platedsteel

D 3 Clevis,stainlesssteel10)

F G Flexocoupling,zinc-platedsteel

X P Oneadditionalpistonrodnut9)

Y 4 Pistonrodnutinstainlesssteel10)

Z 5 Pistonrodnutinacid-proofsteel

6 7 Withoutpistonrodnut

H L Rodguidancemodule,Hstyle,ballbearings18)

J M Rodguidancemodule,Hstyle,plainbearings18)

K Q Rodguidancemodule,Ustyle,plainbearings18)

N R None

No

plug

s

With

plu

gs8)

Page 31: Parker P1D Series Actuators

31

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

TherearethreedifferenttypesofcentretrunnionintheP1Dfamily.AcentretrunnionfortheP1DStandardandonefortheP1DTie-Rodplacedinthecentreoranoptionallocationofthecylinder,oraflangemountedcentretrunniononthefrontorrearendcoverthatfitsallP1Dcylinders.

FortheP1D,thecentretrunnionisavailableamongthecylindermountingsinposition17.IfGor7appearsinposition17,thepositionofthecentretrunnionshouldbespecifiedasathree-digitmeasurementinpositions18-�0.ForP1D-S,000indicatesaloosecentretrunnion.IfDor6appearsinposition17,thecentretrunnionisalwayscentredonthecylinder(no

�) P1DCleanwithoutsensorfunction,seepage41.5) Shaftorpivotssquaretoorinlinewiththecylinderports.6) ForversionsP1D-SandP1D-T7) ForP1D-SandP1D-T,XV-measure(fromthepistonrodthreadaccordingtoISOtothecentreofthepivots)statedinmminpositions18-�0

(max999,or000ifloosecentretrunnionspecified).ForXVmeasures,seepage60.

Examples of centre trunnion P1D-S050MS-0�50NDNNN P1DStandardrodcylinderwithcentretrunnioninstalledincentreofcylinder.P1D-T050MS-0�50NG�05 P1DTierodcylinderwithcentretrunnioninstalledonXVdimensionspecifiedinpositions18,19and�0.P1D-S03�MS-0160NHNNN P1DStandardcylinderwithtrunnionflangemountedonfrontendcover.P1D-S03�MS-0160NJNNN P1DStandardcylinderwithtrunnionflangemountedonrearendcover.

Examples of other combinationsP1D-C050MS-0�501HQN6 P1DCleancylinderwithtrunnionflangemountedonfrontendcover,tworeedsensors,8mmconnector (1mcable),cableconnectiononrearendcover,factoryinstalledstainlesssteelswivelrodeye,push-in fittings(Prestolok,nickelplatedbrass)lowelbowtypefor6mmtube,sealingplugsinstalledinunusedend coverscrews(code1forstainlessswivelrodeye).P1D-F080MSJ0400XJFN0 P1DFlexiblePortingcylinderwithtrunnionflangemountedonrearendcover,twothreadedconnectionsin rearendcover,extrazincplatedsteelpistonrodnut(i.e.atotaloftwozincplatedsteelnuts),twofactory installedelectronicsensors,�4VDC,PNPtype,3mcable,factoryinstalledpush-infittings(Prestolok, nickelplatedbrass)lowelbowtypefor10mmtube.

measurementspecifiedinpositions18-�0).Forsomeofourpreviouscylinderseries,thecentretrunnionisselectedbackinposition5,e.g.P1C-C.RememberthatCinposition5forP1DmeanstheCleancylinderversionandnothingelse!

Itispossibletoequipthecylinderswithfactoryinstalledpistonrodmountings,sensors,fittingsetc.intheusualway.Fortheversionwithoptionallocationofthecentretrunnionorloosecentretrunnion,nochoicescanbemadeforpositions18-�0sincetheyareusedfortheXVdimension.(Seepage60)

P1D cylinders with centre trunnion and cylinder mountings

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – T 0 4 0 M S – 0 3 2 0 N D N N NCylinder version

S Standard

C Clean�)

F FlexiblePorting

T Tie-Rod

Cylinder mountings

90° 0° 90°=shaftsquareto,0°=shaftinlinewithports5)

1 3 FlangeMF1/MF�infrontend

B 4 FlangeMF1/MF�inrearend

2 K FlangeMF1/MF�inbothends

F – FootbracketsMS1(bothends)

C U ClevisbracketGA

E V ClevisbracketMP4

S W Swiveleyebracket

T Y ClevisbracketMP�

L Z ClevisbracketMP�+MP4

X 5 ClevisbracketMP�+pivotbracketwithrigidbearing

Q 0 ClevisbracketGA+pivotbracketwithswivelbearing

M A ClevisbracketGA+swiveleyebracket

D 6 CentretrunnionMT4,midposition6)

G 7 TrunnionMT4,optionalpos.(XV-meas.pos18-�0)7)

H P Trunnionflangeinfrontend

J 8 Trunnionflangeinrearend

N None

Page 32: Parker P1D Series Actuators

3�

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Factory-fitted sensors AllP1Dcylinderscanbesuppliedwithuptofourfactoryinstalledsensors(standardreedorelectronicsensors)inspeciallydesignedgrooves.Bothcableandsensorareprotectedinthegroove.Chooseasensorwith3or10mcableorwith8mmconnector.

P1DCleanhasasystemofsensorsfullyintegratedinthebodyextrusion,inspeciallydesignedgroovesunderneathatransparent,sealedmoulding.Thefactoryinstalledsensorsare

installedattheendpositionsandcantheneasilybemovedanywherealongtheentirestrokeduringcommissioning.Thesensorscanbeorderedwithcableexitinthefrontendcover,rearendcoveroratbothendcovers.

Forcylinderswith3sensors,�sensorsareinstalledintherearendpositionandonesensorinthefrontendposition.Cylinderswith4sensorsaresuppliedwith�sensorsineachendposition.

11)LeftandrightvalidforP1DStandardandP1DTie-Rodseenfrombehindwiththeportsontop.ThesensorscanonlybemountedontheleftforP1DFlexiblePorting.

1�)Nofactory-fittedsensors,butpreparedforcableexitinthefrontend(max.�sensors).13)Nofactory-fittedsensors,butpreparedforcableexitintherearend(max.�sensors).14)Nofactory-fittedsensors,butpreparedforcableexitinbothends(max.4sensors).�1)Thestandardcablelengthis0.�7m.However,P1DCleanissuppliedwith1mcablelength.

Dependingonthelocationofthesensors,thecablelength(1m)maylimitthestrokeoftheP1DCleancylinder

Example of sensors P1D-S050MS-03�0NNCNN P1DStandardwithtwofactoryinstalledsensors�4VDCPNP,8mmconnectorP1D-C063MS-0�50NNLNN P1DCleanwithtwofactoryinstalledReedsensors,3mcableandcableconnectionatrearendcoveronleftsideP1D-F080MS-0400NNMNNP1DFlexiblePortingwithtwofactoryinstalledReedsensors,8mmconnector

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – S 0 5 0 M S – 0 3 2 0 N N C N N

Factory-fitted sensors

Cable exit

F R – �sensors�4VDCpnp,3mcable

G H – �sensors�4VDCpnp,10mcable

C S – �sensors�4VDCpnp,8mmconnector�1)

K L – �sensorsReedtype,3mcable

T V – �sensorsReedtype,10mcable

M Q – �sensorsReedtype,8mmconnector�1)

– – 3 3sensors�4VDCpnp,8mmconnector�1)

– – Z 3sensorsReedtype,8mmconnector�1)

– – 4 4sensors�4VDCpnp,8mmconnector�1)

– – W 4sensorsReedtype,8mmconnector�1)

612) 713) 814) Nofactory-fittedsensorsP1DClean

N NosensorsP1D(excl.P1DClean)

Fron

tend

orl

eft11

)

Rea

rend

orr

ight

11)

Fron

tand

rear

end

Page 33: Parker P1D Series Actuators

33

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

16)P1DCleancylindershavefactoryfittednickelplatedversionsofthePTFseries.

17)NotavailableforP1DFlexiblePortingbore3�-63mm.

Pre-assembled fittings or speed controlsAllP1Dcylinderscanbedeliveredwithelboworstraightpush-infittingsinnickel-platedbrass(Prestolok)orspeedcontrolsinbrass(seriesPTF).P1DCleancylindersarefactory-fittednickel-platedversionsofthePTFspeedcontrols.Pleaseseepage4�fortheordercodekeyforP1DFlexiblePortingwithpre-assembledfittings.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – S 0 5 0 M S – 0 3 2 0 N N N N 8Speed controls or

fittings for tube dimension

Speed controls17) Series PTF 4PB16)

X inbothendsfortube4mm

Y inbothendsfortube6mm

Z inbothendsfortube8mm

P inbothendsfortube10mm

R inbothendsfortube1�mm

Push-in fitting, elbow type for:

4 Tubedimension4mm

6 Tubedimension6mm

8 Tubedimension8mm

0 Tubedimension10mm

2 Tubedimension1�mm

Push-in fitting, straight type for:

1 Tubedimension4mm

3 Tubedimension6mm

5 Tubedimension8mm

7 Tubedimension10mm

9 Tubedimension1�mm

N None

Available fittings and speed controls for P1D Standard

Cyl. Speed controls Elbow fitting Straight fitting bore for tube for tube for tube

32 4,6,8 4,6,8 4,6,8

40, 50 6,8 4,6,8,10,1� 4,6,8,10,1�

63, 80 8,10,1� 8,10,1� 8,10,1�

100, 125 1� 1� 10,1�

Example P1D Standard with factory-fitted fittings or speed controlsP1D-S050MS-03�0NNNN8 P1DStandardcylinderwithtwopush-infittings,elbowtypefor8mmtube.P1D-S1�5MS-0400NNNNR P1DStandardcylinderwithtwospeedcontrolsfor1�mmtube.

Page 34: Parker P1D Series Actuators

34

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Piston rod in alternative materials P1Dhasapolishedstainlesssteelpistonrodasstandard.Ifyouwantadifferentmaterialand/orsurfacetreatment,pleaseorderthisincombinationwithsealmaterialinposition10.

Example of piston rod material P1D-S03�MS-0100 P1DStandardcylinder,bore3�mm,withstainlesssteelpistonrod(standard)P1D-T040MC-0160 P1DTie-Rodcylinder,bore40mm,withhardchromedsteelpistonrod

Pistonrodnutsaresuppliedinzincplatedsteelasstandard,butstainlesssteelpistonrodnutsarealwayssuppliedforP1DClean.Ifanalternativematerialisused,thepistonrodnutisalwayssuppliedinthesamematerial.

Extended piston rod AllcylindersintheP1Dfamilycanbeorderedwithextendedpistonrod,forallpistonrodmaterials.Tomakeitpossibletocombinepistonrodextensionwithallthefunctionsandprop-ertiesintheP1Dsystem,thethreepositionswhichnormally

Example of an extended piston rod P1D-SK45MS-0�00 P1DStandardcylinder,bore3�mm,witha45mmextendedpistonrod.P1D-TPD�MS-0500 P1DTie-Rodcylinder,bore80mm,with13�mmextendedpistonrod.

specifycylinderboreareusedtospecifybothboreandexten-sion.WhenorderingaP1Dcylinderwithextendedpistonrod,specifythisasbelow.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S K R 5 M S – 0 3 2 0Piston rod extension

E.g.KR5=Cylinderbore3�mmwithpistonrodextension=�55mm01-99 1-99 N0-N9 ��0-��9

A0-A9 100-109 P0-P9 �30-�39

B0-B9 110-119 Q0-Q9 �40-�49

C0-C9 1�0-1�9 R0-R9 �50-�59

D0-D9 130-139 S0-S9 �60-�69

E0-E9 140-149 T0-T9 �70-�79

F0-F9 150-159 U0-U9 �80-�89

G0-G9 160-169 V0-V9 �90-�99

H0-H9 170-179 W0-W9 300-309

J0-J9 180-189 X0-X9 310-319

K0-K9 190-199 Y0-Y9 3�0-3�9

L0-L9 �00-�09 Z0-Z9 330-339

M0-M9 �10-�19

Cylinder bore mm

K 3�

L 40

M 50

N 63

P 80

Q 100

R 1�5

Themaximumextendedpistonrodlengththatcanbespecifiedbytheorderkeyis339mm.Ifalongerextendedpistonrodisneededpleasecontactusandwewillorganiseaspecialpartnumber.

Bychangingfrom03�toKR5,thecylinderhasbeengivena�55mmextendedpistonrod.Atthesametime,thecylindercanbespecifiedwithallfunctionsandpropertiesintheotherpositions.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 3 2 M S – 0 1 0 0Piston rod Seals material

S C M R Standard-�0°Cto+80°C.

F G N D Hightemperatureversion6) -10°Cto+150°C.Nomagneticfunction

L K P E Lowtemperatureversion-40°Cto+40°C.6)

– J – Z Lowpressurehydraulic6)�4)

Stai

nles

sst

eel

Chr

omiu

m-p

late

dst

eel

Aci

d-pr

oofs

teel

Chr

om.-p

l.st

ainl

ess

stee

l

6) For P1D-S and P1D-T.24) The seal system for low

pressure hydraulics demands a hard chromed surface for proper function.

Page 35: Parker P1D Series Actuators

35

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

ThenewP1Dsystemcontainscylinderversionsforhighandlowtemperatureandlowpressurehydraulics.Theseversionshavematerialandsealingsystemsspeciallydesignedfortheirparticulartemperatureranges.Endcoversandpistonsaremadeentirelyfrommetal,togiveoptimumfunctionathighorlowtemperatureincombinationwithsealsmadefromspeciallytestedmaterialsandspecialgrease.Thesevariantsareavail-ablewiththeP1D-SandP1D-Tmodels.Thelowtemperatureversionhasamagneticringinthepistonforproximitysensing(butpleasenotethatthesensorsarenormallyspecifiedforfullperformancedownto–�5°Conly),whereasthehightempera-tureversiondoesnothaveamagneticringinthepiston.ThehightemperatureversionischosenbytheletterFinposi-

6) ForP1D-SandP1D-T.�4) Thesealsystemforlowpressurehydraulicsdemandsahardchromedsurfaceforproperfunction.

Examples of high and low temperature, and low pressure hydraulicsP1D-S03�MF-01�5 P1Dcylinder,versionS,hightemperaturedesign,nomagneticfunction.P1D-S050ML-0�50 P1Dcylinder,versionS,lowtemperaturedesign,built-inmagneticring(butthesensorshave normallyacceptablefunctionto–�5°Conly).P1D-S063MF-03�0S1NNN P1Dcylinder,versionS,hightemperaturedesign,nomagneticfunction,zincplatedsteelswivelrodeye, flangeonfrontendcover.P1D-S050MJ-0�00 P1Dcylinder,versionS,lowpressurehydraulicversion,hardchromedpistonrod,magneticringbuiltin.

tion10(orG,D,Nforotherpistonrodmaterials,seethetable).ThelowtemperatureversionischosenbytheletterLinposi-tion10(orK,E,Pforotherpistonrodmaterials,seethetable).OrdercylindersforlowpressurehydraulicsbyspecifyingtheletterJ(hardchromedsteelpistonrod)orZ(hardchromedstainlesssteelpistonrod)inposition10inthetablebelow.Pleasenotethatthisversionrequiresapistonrodwithhardchromedsurface.

Certainrestrictionsapplytochoosingsensors,pistonrodmountings,cylindermountingsandfittingsduetothetempera-turerange.However,thehightemperaturecylinderscannotbesuppliedwithsensors,i.e.alwayscodeNinposition18.

High and low temperature and low pressure hydraulics

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 6 3 M F – 0 3 2 0

Piston rod Seals material

S C M R Standard-�0°Cto+80°C.

F G N D Hightemperatureversion6) -10°Cto+150°C. Nomagneticfunction.

L K P E Lowtemperatureversion6) -40°Cto+40°C.

– J – Z Lowpressurehydraulic�4)�4)

Stai

nles

sst

eel

Chr

omiu

m-p

late

dst

eel

Aci

d-pr

oofs

teel

Chr

om.-p

l.st

ainl

ess

stee

l

Cylinder version

S Standard

C Clean

F FlexiblePorting

T Tie-Rod

Page 36: Parker P1D Series Actuators

36

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Through piston rod AllP1Dcylinderscanbeorderedwithathroughpistonrod.Orderthisdesigninposition9incombinationwiththescraperringsystemasbelow.

Example of through piston rod P1D-S03�FS-0100 P1DStandardcylinder,bore3�mm,withthroughpistonrodP1D-T050FS-01�5 P1DTie-Rodcylinder,bore50mm,withthroughpistonrod

3 and 4 position cylinders Factory-fitted3and4positioncylinderscanbeorderedintie-roddesignP1D-T.Throughgoingtie-rodsfixthetwocylindersintoacompactunit.

Equal stroke – 3 position cylinder SpecifyletterTinposition5(P1D-T)andfigure�inposition9(standardscraperring)

Unequal stroke – 4 position cylinder SpecifyletterTinposition5(P1D-T)andfigure�inposition9(standardscraperring)Specifytheshorteststrokeintheordinarypositions1�,13,14,15andthelongeststrokeinpositions17,18,19,�0.

Example of 3 and 4 position cylinders P1D-T03��S-0�00SNNN4 P1DTie-Rodcylinderwith3position design,swivelrodeyeinzincplatedsteel, factoryinstalledplug-infittings(Prestolok, nickelplatedbrass)for4mmtube.P1D-T063�S-0160 P1DTie-Rodcylinderwith3positiondesignP1D-T080�S-0�00N0�50 P1DTie-Rodcylinderwith4positiondesign withstroke�00mmand�50mm.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – T 0 8 0 2 S – 0 2 0 0 N 0 2 5 0Cylinder version

S Standard

C Clean

F FlexiblePorting

T Tie-Rod

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 3 2 F S – 0 1 0 022) If stainless steel end cover screws

are selected, the piston rod nuts are also supplied in stainless steel.

23) For dry rod operation.25) The metal scraper ring requires a

hard-chromium plated piston rod26) FPM scraper should be chosen

for higher chemical resistance on standard temperature versions only.

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

2 4 6 8 – – – – 3and4positioncylinders

C J K L – – – – Tandem

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

22) If stainless steel end cover screws are selected, the piston rod nuts are also supplied in stainless steel.

23) For dry rod operation.25) The metal scraper ring requires a

hard-chromium plated piston rod26) FPM scraper should be chosen

for higher chemical resistance on standard temperature versions only.

Page 37: Parker P1D Series Actuators

37

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Tandem cylinders TheP1D-Tisavailableintandemdesigni.e.twocylindersinseries,foralmostdoubleforce.OrderwiththeletterCinposition9.

Operation with a dry piston rod Thesealsystemforoperationwithadrypistonrod(HDPEscraper)isavailableasanoptionforallP1Dcylindersexcepthighandlowtemperatureversionandthehydraulicmodel.

Example of seal system for dry rod P1D-S040DS-0�00 P1DStandardcylinderwithsealsystemfordryoperation.P1D-C050DS-0�50TERN6 P1DCleancylinderwithsealsystemfordryoperation,stainlesssteelswivelrodeye,clevisbracketMP4,two factory-fittedelectronicsensors,�4VDC,PNPtype,3mcable,cableexitatrearendcover,factory-fitted push-infittings(Prestolok,nickelplatedbrass)oflowelbowtypefor6mmtube.Foursealingplugsforunusedend coverscrewsareenclosed.P1D-C063DSC03�0DMSN6P1DCleancylinderwithsealsystemfordryoperation,twopush-inlowelbowfittingsplacedatrearendcoverfor6mm tube,stainlesssteelclevis,combinationofclevisbracketGA+swiveleyebracketinstalledonrearendcover, twofactory-fittedelectronicsensors,�4VDC,PNPtype,8mmconnector(1mcable),cableexitatrearendcover. Foursealingplugsforunusedendcoverscrewsareenclosed.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 8 0 D S – 0 2 0 0Cylinder version

S Standard

C Clean

F FlexiblePorting

T Tie-Rod

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – T 0 4 0 C S – 0 3 2 0

OrderthisfunctionbyspecifyingletterDinposition9(doubleactingcylinder)orE(doubleactingcylinderwiththroughpistonrod).Specifythecodeforthesealsystemineitherthe15or�0digitpartnumber.

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

2 4 6 8 – – – – 3and4positioncylinders

C J K L – – – – Tandem

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

2 4 6 8 – – – – 3and4positioncylinders

C J K L – – – – Tandem

22) If stainless steel end cover screws are selected, the piston rod nuts are also supplied in stainless steel.

23) For dry rod operation.25) The metal scraper ring requires a

hard-chromium plated piston rod26) FPM scraper should be chosen

for higher chemical resistance on standard temperature versions only.

22) If stainless steel end cover screws are selected, the piston rod nuts are also supplied in stainless steel.

23) For dry rod operation.25) The metal scraper ring requires a

hard-chromium plated piston rod26) FPM scraper should be chosen

for higher chemical resistance on standard temperature versions only.

Page 38: Parker P1D Series Actuators

38

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Clean with built-in sensor TheentirelynewP1DCleanwithbuilt-insensorshasa�0-digitpartnumbertodefineallfunctions.CylinderversionP1DCleanisselectedbyputtingtheletterCinposition5andthesensorsareselectedinposition18.ThesetwopositionsdeterminethedesignofeachP1DCleancylinder.Ifrequired,thepistonrod

andcylindermountings,pistonrodthreadandfittingsorspeedcontrolscanbeselectedinpositions16,17,19and�0toobtainacompleteworkingunit.Youcanalsospecifythecodefornoneoftheseoptions.Butpleaserememberthatacodemustbespecifiedinallpositions16–�0.

�) P1DCleanwithoutsensorfunction,seepage41.11)LeftandrightvalidforP1DStandardandP1DTie-Rodseenfrombehindwiththeportsontop.Thesensorscanonlybemountedontheleft

forP1DFlexiblePorting.1�)Nofactory-fittedsensors,butpreparedforcableexitinthefrontend(max.�sensors).13)Nofactory-fittedsensors,butpreparedforcableexitintherearend(max.�sensors).14)Nofactory-fittedsensors,butpreparedforcableexitinbothends(max.4sensors).�1)Duetothesensorpositions,thecablelength(1m)couldlimitthestrokeoftheP1DCleancylinders.

Example of P1D Clean P1D-C03�MS-0�00NNCNNP1DCleancylinderwithtwoelectronicsensors,PNPtype,with8mmconnector,cableexitatfrontendcover, 4sealingplugsforendcoverscrewsareenclosed.

P1D-C050MS-0160TNHNN P1DCleancylinderwithtwoelectronicsensors,PNPtype,with10mcable,cableexitatrearendcover, swivelrodeyeinstainlesssteel,4sealingplugsforendcoverscrewsareenclosed.

P1D-C080MS-0�50-3BMNNP1DCleancylinderwithtworeedsensors,with8mmconnector,cableconnectionatfrontendcover,stainlesssteel clevis,flangeonrearendcover,sealingplugsinstalledinunusedendcoverscrews.

P1D-C1�5MS-04004T3NN P1DCleancylinderwiththreeelectronicsensors,PNPtype,with8mmconnector,cableexitatbothfrontand rearendcover(1cablefront,�cablesrear–canbemovedtoinvertedconfiguration),extrastainlesssteelpistonrod nut,clevisbracketMP�onrearendcover,plugsinstalledinunusedendcoverscrews.

P1D-C040MS-03�0RHWNNP1DCleancylinderwithfourelectronicsensors,PNPtype,with8mmconnector,cableexitatbothfrontand rearendcover(�cablesineachendcover),flangemountedtrunniononfrontendcover,sealingplugs installedinunusedendcoverscrews.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – C 0 5 0 M S – 0 3 2 0 N N C N NFactory-fitted sensors, P1D Clean

Cable exit

F R – �sensors�4VDCPNP,3mcable

G H – �sensors�4VDCPNP,10mcable

C S – �sensors�4VDCPNP,8mmconnector,1mcable�1)

K L – �sensorsReedtype,3mcable

T V – �sensorsReedtype,10mcable

M Q – �sensorsReedtype,8mmconnector,1mcable�1)

– – 3 3sensors�4VDCPNP,8mmconnector,1mcable�1)

– – Z 3sensorsReedtype,8mmconnector,1mcable�1)

– – 4 4sensors�4VDCPNP,8mmconnector,1mcable�1)

– – W 4sensorsReedtype,8mmconnector,1mcable�1)

612) 713) 814) Nofactory-fittedsensorsP1DClean

N NosensorsP1D(excl.P1DClean)

Cylinder version

S Standard

C Clean�)

F FlexiblePorting

T Tie-Rod

Fron

tend

orl

eft11

)

Rea

rend

orr

ight

11)

Fron

tand

rear

end

Page 39: Parker P1D Series Actuators

39

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Double acting

Cyl. bore Stroke Order codemm mm

32 �5 P1D-C032MS-0025NNCNNConn.G1/8 40 P1D-C032MS-0040NNCNN 50 P1D-C032MS-0050NNCNN 80 P1D-C032MS-0080NNCNN 100 P1D-C032MS-0100NNCNN 1�5 P1D-C032MS-0125NNCNN 160 P1D-C032MS-0160NNCNN �00 P1D-C032MS-0200NNCNN �50 P1D-C032MS-0250NNCNN 3�0 P1D-C032MS-0320NNCNN 400 P1D-C032MS-0400NNCNN 500 P1D-C032MS-0500NNCNN

40 �5 P1D-C040MS-0025NNCNNConn.G1/4 40 P1D-C040MS-0040NNCNN 50 P1D-C040MS-0050NNCNN 80 P1D-C040MS-0080NNCNN 100 P1D-C040MS-0100NNCNN 1�5 P1D-C040MS-0125NNCNN 160 P1D-C040MS-0160NNCNN �00 P1D-C040MS-0200NNCNN �50 P1D-C040MS-0250NNCNN 3�0 P1D-C040MS-0320NNCNN 400 P1D-C040MS-0400NNCNN 500 P1D-C040MS-0500NNCNN

50 �5 P1D-C050MS-0025NNCNNConn.G1/4 40 P1D-C050MS-0040NNCNN 50 P1D-C050MS-0050NNCNN 80 P1D-C050MS-0080NNCNN 100 P1D-C050MS-0100NNCNN 1�5 P1D-C050MS-0125NNCNN 160 P1D-C050MS-0160NNCNN �00 P1D-C050MS-0200NNCNN �50 P1D-C050MS-0250NNCNN 3�0 P1D-C050MS-0320NNCNN 400 P1D-C050MS-0400NNCNN 500 P1D-C050MS-0500NNCNN

63 �5 P1D-C063MS-0025NNCNNConn.G3/8 40 P1D-C063MS-0040NNCNN 50 P1D-C063MS-0050NNCNN 80 P1D-C063MS-0080NNCNN 100 P1D-C063MS-0100NNCNN 1�5 P1D-C063MS-0125NNCNN 160 P1D-C063MS-0160NNCNN �00 P1D-C063MS-0200NNCNN �50 P1D-C063MS-0250NNCNN 3�0 P1D-C063MS-0320NNCNN 400 P1D-C063MS-0400NNCNN 500 P1D-C063MS-0500NNCNN

P1D CleanTheordernumbersonthispagerefertoP1DCleanwithtwobuilt-inelectronicsensors,factory-fittedinthecylinderendpositions,withcableexitatthefrontendcover.Seetheordercodekeytoselectothersensorsandotherlocationofthecableexit.

Cyl. bore Stroke Order codemm mm

80 �5 P1D-S080MS-0025NNCNNConn.G3/8 40 P1D-C080MS-0040NNCNN 50 P1D-C080MS-0050NNCNN 80 P1D-C080MS-0080NNCNN 100 P1D-C080MS-0100NNCNN 1�5 P1D-C080MS-0125NNCNN 160 P1D-C080MS-0160NNCNN �00 P1D-C080MS-0200NNCNN �50 P1D-C080MS-0250NNCNN 3�0 P1D-C080MS-0320NNCNN 400 P1D-C080MS-0400NNCNN 500 P1D-C080MS-0500NNCNN

100 �5 P1D-C100MS-0025NNCNNConn.G1/� 40 P1D-C100MS-0040NNCNN 50 P1D-C100MS-0050NNCNN 80 P1D-C100MS-0080NNCNN 100 P1D-C100MS-0100NNCNN 1�5 P1D-C100MS-0125NNCNN 160 P1D-C100MS-0160NNCNN �00 P1D-C100MS-0200NNCNN �50 P1D-C100MS-0250NNCNN 3�0 P1D-C100MS-0320NNCNN 400 P1D-C100MS-0400NNCNN 500 P1D-C100MS-0500NNCNN

125 �5 P1D-C125MS-0025NNCNNConn.G1/� 40 P1D-C125MS-0040NNCNN 50 P1D-C125MS-0050NNCNN 80 P1D-C125MS-0080NNCNN 100 P1D-C125MS-0100NNCNN 1�5 P1D-C125MS-0125NNCNN 160 P1D-C125MS-0160NNCNN �00 P1D-C125MS-0200NNCNN �50 P1D-C125MS-0250NNCNN 3�0 P1D-C125MS-0320NNCNN 400 P1D-C125MS-0400NNCNN 500 P1D-C125MS-0500NNCNN

Thecylindersaresuppliedcompletewithonestainlesssteelpistonrodnutand4sealingplugstobeusedintheunusedendcoverscrews.

P1D Clean with electronic sensors 24 VDC, PNP, 1 m cable with 8 mm connector

Page 40: Parker P1D Series Actuators

40

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Double acting

Cyl. bore Stroke Order codemm mm

32 �5 P1D-C032MS-0025NNMNNConn.G1/8 40 P1D-C032MS-0040NNMNN 50 P1D-C032MS-0050NNMNN 80 P1D-C032MS-0080NNMNN 100 P1D-C032MS-0100NNMNN 1�5 P1D-C032MS-0125NNMNN 160 P1D-C032MS-0160NNMNN �00 P1D-C032MS-0200NNMNN �50 P1D-C032MS-0250NNMNN 3�0 P1D-C032MS-0320NNMNN 400 P1D-C032MS-0400NNMNN 500 P1D-C032MS-0500NNMNN

40 �5 P1D-C040MS-0025NNMNNConn.G1/4 40 P1D-C040MS-0040NNMNN 50 P1D-C040MS-0050NNMNN 80 P1D-C040MS-0080NNMNN 100 P1D-C040MS-0100NNMNN 1�5 P1D-C040MS-0125NNMNN 160 P1D-C040MS-0160NNMNN �00 P1D-C040MS-0200NNMNN �50 P1D-C040MS-0250NNMNN 3�0 P1D-C040MS-0320NNMNN 400 P1D-C040MS-0400NNMNN 500 P1D-C040MS-0500NNMNN

50 �5 P1D-C050MS-0025NNMNNConn.G1/4 40 P1D-C050MS-0040NNMNN 50 P1D-C050MS-0050NNMNN 80 P1D-C050MS-0080NNMNN 100 P1D-C050MS-0100NNMNN 1�5 P1D-C050MS-0125NNMNN 160 P1D-C050MS-0160NNMNN �00 P1D-C050MS-0200NNMNN �50 P1D-C050MS-0250NNMNN 3�0 P1D-C050MS-0320NNMNN 400 P1D-C050MS-0400NNMNN 500 P1D-C050MS-0500NNMNN

63 �5 P1D-C063MS-0025NNMNNConn.G3/8 40 P1D-C063MS-0040NNMNN 50 P1D-C063MS-0050NNMNN 80 P1D-C063MS-0080NNMNN 100 P1D-C063MS-0100NNMNN 1�5 P1D-C063MS-0125NNMNN 160 P1D-C063MS-0160NNMNN �00 P1D-C063MS-0200NNMNN �50 P1D-C063MS-0250NNMNN 3�0 P1D-C063MS-0320NNMNN 400 P1D-C063MS-0400NNMNN 500 P1D-C063MS-0500NNMNN

P1D CleanTheordernumbersonthispagerefertoP1DCleanwithtwobuilt-inreedsensors,factory-fittedinthecylinderendposi-tions,withcableexitatthefrontendcover.Seetheordercodekeytoselectothersensorsandotherlocationofthecableexit.

Cyl. bore Stroke Order codemm mm

80 �5 P1D-S080MS-0025NNMNNConn.G3/8 40 P1D-C080MS-0040NNMNN 50 P1D-C080MS-0050NNMNN 80 P1D-C080MS-0080NNMNN 100 P1D-C080MS-0100NNMNN 1�5 P1D-C080MS-0125NNMNN 160 P1D-C080MS-0160NNMNN �00 P1D-C080MS-0200NNMNN �50 P1D-C080MS-0250NNMNN 3�0 P1D-C080MS-0320NNMNN 400 P1D-C080MS-0400NNMNN 500 P1D-C080MS-0500NNMNN

100 �5 P1D-C100MS-0025NNMNNConn.G1/� 40 P1D-C100MS-0040NNMNN 50 P1D-C100MS-0050NNMNN 80 P1D-C100MS-0080NNMNN 100 P1D-C100MS-0100NNMNN 1�5 P1D-C100MS-0125NNMNN 160 P1D-C100MS-0160NNMNN �00 P1D-C100MS-0200NNMNN �50 P1D-C100MS-0250NNMNN 3�0 P1D-C100MS-0320NNMNN 400 P1D-C100MS-0400NNMNN 500 P1D-C100MS-0500NNMNN

125 �5 P1D-C125MS-0025NNMNNConn.G1/� 40 P1D-C125MS-0040NNMNN 50 P1D-C125MS-0050NNMNN 80 P1D-C125MS-0080NNMNN 100 P1D-C125MS-0100NNMNN 1�5 P1D-C125MS-0125NNMNN 160 P1D-C125MS-0160NNMNN �00 P1D-C125MS-0200NNMNN �50 P1D-C125MS-0250NNMNN 3�0 P1D-C125MS-0320NNMNN 400 P1D-C125MS-0400NNMNN 500 P1D-C125MS-0500NNMNN

Thecylindersaresuppliedcompletewithonestainlesssteelpistonrodnutand4sealingplugstobeusedintheunusedendcoverscrews.

P1D Clean with Reed sensors, 1 m cable with 8 mm connector

Page 41: Parker P1D Series Actuators

41

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Clean without sensor function Theonlyexceptionfromthe�0-digitpartnumberisoneversionofP1DCleanwhichhasa15-digitordernumber.ThisversionisapermanentlysealedP1DCleanwithnofacilityforinstallingsensors.Theexteriorofthiscylinderischaracterisedbynothavingthebigtransparentcover,ithasinsteadtwoshortcoverswithatransparentmouldingbetween.Thecylinderhasaverycleandesignandisintendedforapplicationswherenosensorsareused.

TheP1Dwithoutthesensorfunctioncanofcoursebecombinedwithotherequipmentandfunctionsbyusinga�0-digitordernumber.ButpleasenotethattheletterNmustalwaysbeusedinposition18.

Double acting

Cyl. bore Stroke Order codemm mm

32 �5 P1D-C032MS-0025Conn.G1/8 40 P1D-C032MS-0040 50 P1D-C032MS-0050 80 P1D-C032MS-0080 100 P1D-C032MS-0100 1�5 P1D-C032MS-0125 160 P1D-C032MS-0160 �00 P1D-C032MS-0200 �50 P1D-C032MS-0250 3�0 P1D-C032MS-0320 400 P1D-C032MS-0400 500 P1D-C032MS-0500

40 �5 P1D-C040MS-0025Conn.G1/4 40 P1D-C040MS-0040 50 P1D-C040MS-0050 80 P1D-C040MS-0080 100 P1D-C040MS-0100 1�5 P1D-C040MS-0125 160 P1D-C040MS-0160 �00 P1D-C040MS-0200 �50 P1D-C040MS-0250 3�0 P1D-C040MS-0320 400 P1D-C040MS-0400 500 P1D-C040MS-0500

50 �5 P1D-C050MS-0025Conn.G1/4 40 P1D-C050MS-0040 50 P1D-C050MS-0050 80 P1D-C050MS-0080 100 P1D-C050MS-0100 1�5 P1D-C050MS-0125 160 P1D-C050MS-0160 �00 P1D-C050MS-0200 �50 P1D-C050MS-0250 3�0 P1D-C050MS-0320 400 P1D-C050MS-0400 500 P1D-C050MS-0500

Cyl. bore Stroke Order codemm mm

63 �5 P1D-C063MS-0025Conn.G3/8 40 P1D-C063MS-0040 50 P1D-C063MS-0050 80 P1D-C063MS-0080 100 P1D-C063MS-0100 1�5 P1D-C063MS-0125 160 P1D-C063MS-0160 �00 P1D-C063MS-0200 �50 P1D-C063MS-0250 3�0 P1D-C063MS-0320 400 P1D-C063MS-0400 500 P1D-C063MS-0500

80 �5 P1D-C080MS-0025Conn.G3/8 40 P1D-C080MS-0040 50 P1D-C080MS-0050 80 P1D-C080MS-0080 100 P1D-C080MS-0100 1�5 P1D-C080MS-0125 160 P1D-C080MS-0160 �00 P1D-C080MS-0200 �50 P1D-C080MS-0250 3�0 P1D-C080MS-0320 400 P1D-C080MS-0400 500 P1D-C080MS-0500

100 �5 P1D-C100MS-0025Conn.G1/� 40 P1D-C100MS-0040 50 P1D-C100MS-0050 80 P1D-C100MS-0080 100 P1D-C100MS-0100 1�5 P1D-C100MS-0125 160 P1D-C100MS-0160 �00 P1D-C100MS-0200 �50 P1D-C100MS-0250 3�0 P1D-C100MS-0320 400 P1D-C100MS-0400 500 P1D-C100MS-0500

Cyl. bore Stroke Order codemm mm

125 �5 P1D-C125MS-0025Conn.G1/� 40 P1D-C125MS-0040 50 P1D-C125MS-0050 80 P1D-C125MS-0080 100 P1D-C125MS-0100 1�5 P1D-C125MS-0125 160 P1D-C125MS-0160 �00 P1D-C125MS-0200 �50 P1D-C125MS-0250 3�0 P1D-C125MS-0320 400 P1D-C125MS-0400 500 P1D-C125MS-0500

Thecylindersaresuppliedcompletewithonestainlesssteelpistonrodnutand4sealingplugstobeusedintheunusedendcoverscrews.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – C 0 4 0 M S – 0 2 5 0

P1D Clean without sensor function is defined by the letter C in position 5 and the 15-digit order number

Cylinder version

S Standard

C Clean

F FlexiblePorting

T Tie-Rod

Page 42: Parker P1D Series Actuators

4�

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

P1D Flexible PortingTheP1DFlexiblePortingwithbothcylinderportsinoneendcoverhasa�0-digitpartnumber.Position11isusedtoselectthepositionofthecylinderports(allcylinderswithoneconnec-tionineachendcoverhaveadashinthisposition).Pleasenotethatcylinderbores3�-63mmonlyhavethepush-infittingdesignand80-1�5mmisonlyavailablewiththreadedconnec-tions.Position�0isusedtospecifythetypeofpush-infittings(lowelboworstraightfitting)andtubedimension(4or6mm

Examples of P1D Flexible Porting P1D-F050MSB0160SMKN8FlexiblePortingcylinderwithtwoplug-inlowelbowfittingsfor8mmtube,placedatfrontendcover,zincplatedsteel swivelrodeye,combinationclevisbracketGAandswiveleyebracketinstalledonrearendcover, twofactory-fittedreedsensorswith3mcable.

P1D-F080MSH0500BFCN FlexiblePortingcylinderwithtwothreadedconnectionsinfrontendcover,zincplatedsteelclevis,footbrackets,two factory-fittedelectronicsensors,PNPtype,with8mmconnector(0.3mcable),sealingplugsinstalledinunusedend coverscrews.

P1D-F03�MSB0�50NNNN6FlexiblePortingcylinderwithtwopush-inelbowfittingsfor6mmtube,placedatfrontendcover.

P1D-F063MSC0400NNNN7FlexiblePortingcylinderwithtwostraightpush-infittingsfor10mmtube,placedatrearendcover (onlypossibletochoose8or10mmforcylinderbore50and63mm).

P1D-F1�5MSJ0600NNNNNFlexiblePortingcylinderwithtwothreadedconnectionsinrearendcover.

forØ3�and40,and8or10mmforØ50and63).ForcylinderboresØ3�-63mm,thefittingsaremadeofplasticsmaterialforFlexiblePortingcylinders(nickelplatedbrassonallotherP1Dcylinders).Thesefoursmallestborescannotbeequippedwithspeedcontrols.ForcylinderboresØ80-1�5mm,position�0isusedtoselectthespeedcontrols,fittings(Prestolok,nickelplatedbrass)ornone(codeN).

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – F 0 6 3 M S B 0 3 2 0 N N N N 0Cylinder version

S Standard

C Clean

F FlexiblePorting

T Tie-Rod

3) OnlyforP1D-Fbore80-1�5mm.Selectoptionalfittingsinposition�0.

4) OnlyforP1D-Fbore3�-63mm.Selectfittingsinposition�0.

16)P1DCleancylindershavefactoryinstallednickelplatedversionsofthePTFseries.

17)NotavailableforP1DFlexiblePortingbore3�-63mm.

Fron

t&re

ar

Bot

hfro

nt

Bot

hre

arCylinder ports

Port location

H3) J3) Gthreads,BSPP(Ø80-1�5mm)

– B4) C4) Push-in,metric(Ø3�-63mm)

Available fittings and speed controls for P1D Flexible Porting

Cyl. Speed controls Elbow fitting Straight fitting bore for tube for tube for tube

32, 40 notavailable 4,6 4,6

50, 63 notavailable 8,10 8,10

80 8,10,1� 8,10,1� 8,10,1�

100, 125 1� 1� 10,1�

Speed controls or fittings for tube dimension

Speed controls17) Series PTF4PB16)

X inbothendsfortube4mm

Y inbothendsfortube6mm

Z inbothendsfortube8mm

P inbothendsfortube10mm

R inbothendsfortube1�mm

Push-in fitting, elbow type for:

4 Tubedimension4mm

6 Tubedimension6mm

8 Tubedimension8mm

0 Tubedimension10mm

2 Tubedimension1�mm

Push-in fitting, straight type for:

1 Tubedimension4mm

3 Tubedimension6mm

5 Tubedimension8mm

7 Tubedimension10mm

9 Tubedimension1�mm

N None

Page 43: Parker P1D Series Actuators

43

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

Ø80-1�5mm

Ø3�-63mm

P1D Flexible PortingDouble acting

Cyl. bore Stroke Order codemm mm

32 �5 P1D-F032MSB0025NNNN6Push-inelbow6mm 40 P1D-F032MSB0040NNNN6 50 P1D-F032MSB0050NNNN6 80 P1D-F032MSB0080NNNN6 100 P1D-F032MSB0100NNNN6 1�5 P1D-F032MSB0125NNNN6 160 P1D-F032MSB0160NNNN6 �00 P1D-F032MSB0200NNNN6 �50 P1D-F032MSB0250NNNN6 3�0 P1D-F032MSB0320NNNN6 400 P1D-F032MSB0400NNNN6 500 P1D-F032MSB0500NNNN6

40 �5 P1D-F040MSB0025NNNN6Push-inelbow6mm 40 P1D-F040MSB0040NNNN6 50 P1D-F040MSB0050NNNN6 80 P1D-F040MSB0080NNNN6 100 P1D-F040MSB0100NNNN6 1�5 P1D-F040MSB0125NNNN6 160 P1D-F040MSB0160NNNN6 �00 P1D-F040MSB0200NNNN6 �50 P1D-F040MSB0250NNNN6 3�0 P1D-F040MSB0320NNNN6 400 P1D-F040MSB0400NNNN6 500 P1D-F040MSB0500NNNN6

50 �5 P1D-F050MSB0025NNNN0Push-inelbow10mm 40 P1D-F050MSB0040NNNN0 50 P1D-F050MSB0050NNNN0 80 P1D-F050MSB0080NNNN0 100 P1D-F050MSB0100NNNN0 1�5 P1D-F050MSB0125NNNN0 160 P1D-F050MSB0160NNNN0 �00 P1D-F050MSB0200NNNN0 �50 P1D-F050MSB0250NNNN0 3�0 P1D-F050MSB0320NNNN0 400 P1D-F050MSB0400NNNN0 500 P1D-F050MSB0500NNNN0

63 �5 P1D-F063MSB0025NNNN0Push-inelbow10mm 40 P1D-F063MSB0040NNNN0 50 P1D-F063MSB0050NNNN0 80 P1D-F063MSB0080NNNN0 100 P1D-F063MSB0100NNNN0 1�5 P1D-F063MSB0125NNNN0 160 P1D-F063MSB0160NNNN0 �00 P1D-F063MSB0200NNNN0 �50 P1D-F063MSB0250NNNN0 3�0 P1D-F063MSB0320NNNN0 400 P1D-F063MSB0400NNNN0 500 P1D-F063MSB0500NNNN0

P1D Flexible Porting TheordercodesonthispagerefertoP1DFlexiblePortingwithbothcylinderportsinthefrontendcoverandwithfactory-fittedpush-inelbowfittings.ForØ3�-63mm,thefittingsaremadeofplastic,whereasØ80-1�5mmcanbeorderedwiththreadedportsonlyorwithpush-inPrestoloknickelplatedbrassfittings.Seetheorderkeytoselectfittings.

P1D Flexible PortingDouble acting

Cyl. bore Stroke Order codemm mm

80 �5 P1D-S080MSH0025NNNN0Push-inelbow10mm 40 P1D-F080MSH0040NNNN0 50 P1D-F080MSH0050NNNN0 80 P1D-F080MSH0080NNNN0 100 P1D-F080MSH0100NNNN0 1�5 P1D-F080MSH0125NNNN0 160 P1D-F080MSH0160NNNN0 �00 P1D-F080MSH0200NNNN0 �50 P1D-F080MSH0250NNNN0 3�0 P1D-F080MSH0320NNNN0 400 P1D-F080MSH0400NNNN0 500 P1D-F080MSH0500NNNN0

100 �5 P1D-F100MSH0025NNNN2Push-inelbow1�mm 40 P1D-F100MSH0040NNNN2 50 P1D-F100MSH0050NNNN2 80 P1D-F100MSH0080NNNN2 100 P1D-F100MSH0100NNNN2 1�5 P1D-F100MSH0125NNNN2 160 P1D-F100MSH0160NNNN2 �00 P1D-F100MSH0200NNNN2 �50 P1D-F100MSH0250NNNN2 3�0 P1D-F100MSH0320NNNN2 400 P1D-F100MSH0400NNNN2 500 P1D-F100MSH0500NNNN2

125 �5 P1D-F125MSH0025NNNN2Push-inelbow1�mm 40 P1D-F125MSH0040NNNN2 50 P1D-F125MSH0050NNNN2 80 P1D-F125MSH0080NNNN2 100 P1D-F125MSH0100NNNN2 1�5 P1D-F125MSH0125NNNN2 160 P1D-F125MSH0160NNNN2 �00 P1D-F125MSH0200NNNN2 �50 P1D-F125MSH0250NNNN2 3�0 P1D-F125MSH0320NNNN2 400 P1D-F125MSH0400NNNN2 500 P1D-F125MSH0500NNNN2

Thecylindersaresuppliedcompletewithonezincplatedsteelpistonrodnut.

Page 44: Parker P1D Series Actuators

44

P1D Cylinder

08.01

www.parker.com/euro_pneumatic

AllCleancylinderscanbecombinedwiththeconnectionsinthefrontorrearendcoverinaccordancewiththeFlexiblePortingdesign.SpecifycylinderversionCinposition5,posi-tionofconnectionportsinposition11(codesH,J,BorC),choiceofbuilt-insensorsinposition18andtypeoffittingand

Examples of P1D Clean in combination with Flexible Porting P1D-C03�MSC0�00NNSN6P1DCleancylinderwithtwopush-inelbowfittingsfor6mmtube,placedatfrontendcover,twofactory-fitted electronicsensors,PNPtype,with8mmconnector,cableexitatrearendcover,4sealingplugsforend coverscrewsareenclosed.

P1D-C080MSJ0500AN3N0 P1DCleancylinderwithtwothreadedconnectionsinrearendcover,factory-fittedpush-inelbowfittings(Prestolok, nickelplatedbrass)for10mmtubeinbothconnections,threefactory-fittedelectronicsensors,PNPtype,with 8mmconnector,cableexitinbothfrontandrearendcovers,zincplatedsteelswivelrodeye,4sealingplugsare installedinunusedendcoverscrews.

Combine P1D Clean and P1D Flexible Porting tubedimensioninposition�0.Naturally,thecylindercanbeequippedwithpistonrodfittingsandcylindermountingsinpositions16and17ifrequired.Aswithallcleancylindersasetof4sealingplugsisenclosedforinstallationinunusedendcoverscrews.

�) P1DCleanwithoutsensorfunction,seepage41.3) OnlyforP1D-Fbore80-1�5mm.Selectoptionalfittingsinposition

�0.4) OnlyforP1D-Fbore3�-63mm.Selectfittingsinposition�0.11)LeftandrightvalidforP1DStandardandP1DTie-Rodseenfrom

behindwiththeportsontop.ThesensorscanonlybemountedontheleftforP1DFlexiblePorting.

1�)Nofactory-fittedsensors,butpreparedforcableexitinthefrontend(max.�sensors).

13)Nofactory-fittedsensors,butpreparedforcableexitintherearend(max.�sensors).

14)Nofactory-fittedsensors,butpreparedforcableexitinbothends(max.4sensors).

15)Tochoosespeedcontrolandcouplings,pleaserefertopage4�.16)P1DCleancylindershavefactoryfittednickelplatedversions

ofthePTFseries.17)NotavailablewithP1DFlexiblePortingbore3�-63mm.�1)Duetothesensorpositions,thecablelength(1m)couldlimitthe

strokeoftheP1DCleancylinders.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – C 0 5 0 M S B 0 3 2 0 N N C N 8Cylinder version

S Standard

C Clean�)

F FlexiblePorting

T Tie-Rod

Fron

t&re

ar

Bot

hfro

nt

Bot

hre

ar

Cylinder ports

Port location

H3) J3) Gthreads,BSPP(Ø80-1�5mm)

– B4) C4) Push-in,metric(Ø3�-63mm)

Speed controls or

fittings for tube dimension

Speed controls17) Series PTF 4/8PB16)

X inbothendsfortube4mm15)

Y inbothendsfortube6mm15)

Z inbothendsfortube8mm15)

P inbothendsfortube10mm15)

R inbothendsfortube1�mm15)

Push-in fitting, elbow type for:

4 Tubedimension4mm15)

6 Tubedimension6mm15)

8 Tubedimension8mm15)

0 Tubedimension10mm15)

2 Tubedimension1�mm15)

Push-in fitting, straight type for:

1 Tubedimension4mm15)

3 Tubedimension6mm15)

5 Tubedimension8mm15)

7 Tubedimension10mm15)

9 Tubedimension1�mm15)

N None

Factory-fitted sensors

Cable exit

F R – �sensors�4VDCPNP,3mcable

G H – �sensors�4VDCPNP,10mcable

C S – �sensors�4VDCPNP,8mmconnector,1mcable�1)

K L – �sensorsReedtype,3mcable

T V – �sensorsReedtype,10mcable

M Q – �sensorsReedtype,8mmconnector,1mcable�1)

– – 3 3sensors�4VDCPNP,8mmconnector,1mcable�1)

– – Z 3sensorsReedtype,8mmconnector,1mcable�1)

– – 4 4sensors�4VDCPNP,8mmconnector,1mcable�1)

– – W 4sensorsReedtype,8mmconnector,1mcable�1)

612) 713) 814) Nofactory-fittedsensorsP1DClean

N NosensorsP1D(excl.P1DClean)

Fron

tend

orl

eft11

)

Rea

rend

orr

ight

11)

Fron

tand

rear

end

Page 45: Parker P1D Series Actuators

45

08.01

www.parker.com/euro_pneumatic

P1D complete working unitP1DStandardcanbeorderedwithafactory-fittedvalveandtubing.ThevalveseriesistherobustandcompactVikingseries,withproductcodeP�L-A(forcylinderbores3�-63),P�L-B(forcylinderbores80-100)andP�L-D(forcylinderbore1�5).Thisvalveserieswasspeciallydesignedforharshenvironmentsandalongservicelife.Thevalveissecurelyfittedtoafixingplateboltedontothecylinderbarrel.Theunitisdeliveredcompletewithvalve,Prestolokpush-inconnec-tioninnickelplatedbrass,andhosing.Thevalvehasbuilt-insilencers(Siflowforspeedregulation),andelectrically-oper-atedversionshavesolenoidvalves(P�Ewithspring-loadedmanualoverride)andacableheadwithLEDandsparkdisper-sion.Thesupplyvoltageis�4VforACaswellasDCversions.ThisUC(UniversalCurrent)ispossiblebecauseofabuilt-inrectifierinthecablehead,allowingtheuseofdirectcurrentandalternatingcurrentforactuation.Ofcourse,theentirerangeofP1DaccessoriescanalsobeusedfortheP1Dwithbuilt-invalve,andcylinderscanbeorderedwithfactory-fittedaccessoriesandsensors.

Fast responseThelargeflowcapacityofthevalveandtheshortdistancebetweenthevalveandthecylinderportsmeanthattheworkingunitoperatesquickly(shortactuationtimeandwithminimalflowrestriction).

P1D FactoryFittedValve

No maintenance and easy to serviceTheworkingunitisbuiltfromstandardcomponents.Thecylindersandthevalvesaredesignedtobeusedwithoutsupplementarylubrication.

Wide range of applicationsThecompleteworkingunitcanbeusedinsiloapplications,foroperatingflapsandvalves,insawmillsandinmanysimilarinstallationsinwhichthecylindersarescatteredorthefastactuationisimportant.Theunitwiththevalveinstallediscompact,soitcanalsobeusedinsmallspaces.

Range of solenoid valve voltagesThesolenoidvalvesareavailableinthestandardvoltages,forexample;�4VUC(�4VAC/DC,UniversalCurrent)115V/50Hz,1�0V/60Hz�30V/50Hz,�40V/60Hz

Page 46: Parker P1D Series Actuators

46

08.01

www.parker.com/euro_pneumatic

Technical dataWorkingpressure max10barWorkingmedia dryfilteredcompressedair. Pleaserefertopage18.Workingtemperature: –�0°Cto+70°C (–15°Cto+60°Cwithsolenoidvalve)Flow,P�L-A,acc.toISO6358 Qn=760Nl/minFlow,P�L-B,acc.toISO6358Qn=10�0Nl/minFlow,P�L-D,acc.toISO6358Qn=�880Nl/minSolenoidpowerconsumption Pull HoldP�E-KV3�C1,�4VDC 1,�W 1,�WP�E-KV31C1,�4VAC 3,5VA 1,6VA

Material specificationP1Dcylinders pleaserefertopage19.Valves1)

Housingandends AnodisedaluminiumSolenoidvalves Housing Polyamide Magnetcoil EpoxycoatedFixingplate AnodisedaluminiumFixingscrewsforplate StainlesssteelFixingscrewsforvalve Zinc-coatedsteelAngleconnections Nickel-coatedbrassPlastictubes PUR1)seealsocatalogueforP�LseriesVikingvalves

Accessories

Name Ordercode

SiflowsilencerforP�L-Avalve,G1/8 9301050901SinteredplasticsilencerforP�L-Avalve,G1/8 P6M-PAB1

SiflowsilencerforP�L-Bvalve,G1/4 9301050902SinteredplasticsilencerforP�L-Bvalve,G1/4 P6M-PAB2

SiflowsilencerforP�L-Dvalve,G1/� 9301050904SinteredplasticsilencerforP�L-Dvalve,G1/� P6M-PAB4FixingplateforØ3�-Ø63,valveP�L-A,-B 9121742111FixingplateforØ80,Ø100,valveP�L-A,-B,-D 9121742112FixingplateforØ1�5,valveP�L-A,-B,-D 9121742113

Factory Fitted ValveA�0-characterordernumberisusedtoordertheP1DStandardwithfactoryfittedvalve.Position5indicatesthecylinderversion,withtheactuationtypeinposition11andthevalvetypeinposition�0.Notethatcylinderdiameters3�-63usevalveP�L-A(1/8"),diameters80-100useP�L-B

(1/4"),anddiameter1�5usesP�L-D(1/�").Thisversionofthecylindercanofcoursebecombinedwithfactory-fittedcylinderaccessories,pistonrodaccessoriesandsensors.Fixingplatesfordifferentvalvesizesmaybeorderedseparately.

P1D FactoryFittedValve

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – V 0 5 0 M S 1 0 3 2 0 N N N N H

Cylinder version

V Standardwithfactoryfittedvalve

4 Standardwithlockunit andfactoryfittedvalve

Valve function

Air actuated

A Air-Air,5/�

B Air-Spring,5/�

C Air-Air,5/3,closedcentreposition

D Air-Air,5/3,ventedcentre

E Air-Air,5/3,pressurisedcentre

Electrically actuated internal supply

F Elec-Elec,5/�

H Elec-Spring,5/�

K Spring-Elec*,5/�

M Elec-Elec,5/3,closedcentreposition

Q Elec-Elec,5/3,ventedcentre

S Elec-Elec,5/3,pressurisedcentre

Electrically actuated external supply

G Elec-Elec,5/�

J Elec-Spring,5/�

L Spring-Elec*,5/�

Factory fitted valve type

0 Airactuated

1 Electricallyactuated �4VUC,LED+VDR (AC/DCUniversalCurrent) Completewithrectifier

4 Electricallyactuated �4VUC,LED+VDRwith 5mintegralcable (AC/DCUniversalCurrent) Completewithrectifier

7 Electricallyactuated �4VUC,LED+VDRwith 10mintegralcable (AC/DCUniversalCurrent) Completewithrectifier

2 Electricallyactuated 115V/50Hz,1�0V/60Hz, LED+VDR

3 Electricallyactuated �30V/50Hz,�40V/60Hz, LED+VDR

* Pistonrodinextendedpositionwithunactuatedvalve

Page 47: Parker P1D Series Actuators

47

08.01

www.parker.com/euro_pneumatic

P1D FactoryFittedValve

DimensionsCylinderbore AM B BA BG D D4 E G KK L� L8 L1�mm mm mm mm mm mm mm mm mm mm mm mm

3� �� 30 30 16 1� 45,0 50,0 �8,5 M10x1,�5 16,0 94 6,0 40 �4 35 35 16 16 5�,0 57,4 33,0 M1�x1,�5 19,0 105 6,5 50 3� 40 40 16 �0 60,7 69,4 33,5 M16x1,5 �4,0 106 8,0 63 3� 45 45 16 �0 71,5 8�,4 39,5 M16x1,5 �4,0 1�1 8,0 80 40 45 45 17 �5 86,7 99,4 39,5 M�0x1,5 30,0 1�8 10,0100 40 55 55 17 �5 106,7 116,0 44,5 M�0x1,5 3�,4 138 14,01�5 54 60 60 �0 3� 134,0 139,0 51,0 M�7x� 45,0 160 18,0

Cylinderbore PP R RT SS SW VA VD WH U V Xmm mm mm mm mm mm mm mm mm mm mm

3� �1,8 3�,5 M6 4,0 10 3,5 4,5 �6 55 40 -9+S/� 40 �1,9 38,0 M6 8,0 13 3,5 4,5 30 55 40 -8+S/� 50 �3,0 46,5 M8 4,0 17 3,5 5,0 37 55 40 -8+S/� 63 �7,4 56,5 M8 6,5 17 3,5 5,0 37 55 40 -6,5+S/� 80 30,5 7�,0 M10 0 �� 3,5 4,0 46 55 54 -�,5+S/�100 35,8 89,0 M10 0 �� 3,5 4,0 51 55 54 -�,5+S/�1�5 40,5 110,0 M1� 0 �7 5,5 6,0 65 55 65 �+S/�

Cylinderbore Y YY Z ZZmm mm mm mm mm

3� 80 56 80 90 40 88 64 87 96 50 10� 78 96 105 63 109 85 107 116 80 136 10� 13� 1�5100 151 117 148 1401�5 185 146 183 159S=Stroke1)Airactuated5/�and5/3�)Electricallyactuated5/�withspringreturn3)Electricallyactuated5/�and5/3(�solenoidvalves)4)Electricallyactuated5/�withspringreturn(reversefunction)

AM

ØB YY

Y

ØD

KK

VD

G

WH

L2

L12Ø

D4

PP

SS

ØB

A

VAGXU

1) 78 (P2L-A), 111 (P2L-B), 164 (P2L-D)

4) 124 (P2L-A), 156 (P2L-B), 192 (P2L-D)

2) 124 (P2L-A), 156 (P2L-B), 192 (P2L-D)

3) 169 (P2L-A), 203 (P2L-B), 280 (P2L-D)

2) 3) 34 (P2L-A)2) 3) 24 (P2L-B)2) 3) 17 (P2L-D)V

X

Z

ZZ

L8 + S

RT

R

E

DIN 439B

SW

CAD drawings on the InternetOurhomepagewww.parker.com/euro_pneumaticincludestheAirCadDrawingLibrarywith�Dand3Ddrawingsforthemainversions.

Page 48: Parker P1D Series Actuators

48

08.01

www.parker.com/euro_pneumatic

P1D cylinder with piston rod lockingTheP1Dcylinderisavailableinaversionwithpistonrodlocking,allowingthepistonrodtobelockedinanyposition.Thelockunit,oftheair/springactuatedtype,isintegratedinthefrontendpieceofthecylinder.Withnosignalpressure,thefullforceofthelockisappliedtothepistonrod,andthelockisreleasedat4barsignalpressure.LockunitsareavailableforP1DStandard(P1D-L)andP1DClean(P1D-D)inbores3�-1�5mm.P1DStandardcanbeorderedwithalockunitandabuilt-invalve(P1D-4).Ofcourse,theentirerangeofP1Daccessoriescanalsobeusedforthelockingcylinder,whichcanbeorderedwithfactoryfittedaccessories,sensorsandvalves.However,thelockunitincreasestheoveralllengthofthecylinder.Comparethedimensionaldiagramsonpages�6and51.Theoveralldimensionsspecifiedinthecatalogueforbuilt-incylinderfittings,pages56-64,areonlycorrectforP1Dstandardversionswithoutlockunit.

Clean and compact designThefrontendpieceandlockunitformanintegratedblock,keepingthelengthofthestructureshort.Thedesigniseasytoclean,sealedandwaterproof.Theexhaustairfromthe

P1D Pistonrodlocking

lockunitcanberemovedbyreplacingthefilterunitwithaconnectorandhose.Thisisanadvantageintermsofcleaningorwhenenvironmentalfactorsareimportant.

Locking and braking.Thestaticlockingforcecorrespondsto7barpressure.Undercertaincircumstances,thelockcanalsobeusedasabrakeforpositioningorsimilarapplications.Themaximumvaluessetoutinthegraphonpage49mustnotbeexceeded.

Function on pressure lossThepistonrodlockcanbeusedinallmaterialhandlingsystemswherecontrolledfasteningorpositioningisrequired.Thepistonrodlockisalsosuitableforuseasapressure-lossbrakeforcylinderswithsuspendedloads,forexample.Seelockforces.Thesignalairtothelockunitcanbeconnecteddirectlytotheairsystemortothesupplyairforthevalvecontrollingthecylinderinquestion.Forcontrolledon/offoperationofthelockunit,aseparatevalve,withlargeexhaustflowcapacity,isused.

P1D-L

P1D-D

Page 49: Parker P1D Series Actuators

49

08.01

www.parker.com/euro_pneumatic

Technical dataWorkingpressure max10barWorkingmedia dryfilteredcompressedairWorkingtemperature –�0°Cto+80°CReleasepressure1) min4bar±10%

1)Signalpressuretoinletportoflockunit.

Static lock forcesLockforcesat0barsignalpressuretolockunit

Cylinderdia. Lockforcemm N

3� 550 40 860 50 1345 63 �140 80 3450100 53901�5 84�5

Material specification, piston rod lockingHousing/endpiece BlackanodisedaluminiumLockcollar/piston HardenedsteelSprings StainlesssteelPistonrodsealDim3�-40 UHMWPEplasticPistonrodsealDim50-1�5 PolyurethaneO-rings Nitrilerubber,NBRScraperring PolyurethaneAirfilter Brass/sinteredbronze

Otherdataasforrelevantbasecylinder.

Thecylindersaresuppliedwithahardchromeplatedpistonrod.

NOTE!Ifrodguidensemoduleistobefitted,thepistonrodmustbeextendedtoprovidethesameWHdimensionsasfortheP1Dbasecylinder.Pleaserefertopage5�.

P1D Pistonrodlocking

Piston rod lockingToorderacylinderwithpistonrodlocking,position5shouldcontainL(P1DStandardwithlockunit),D(P1DCleancylinderwithlockunit)or4(P1Dwithfactoryfittedvalveandlockunit).NotethattheP1Dwithpistonrodlockingrequiresa

chromeplatedpistonrodorchromeplatedstainlesssteelpistonrodbecauseofthehighsurfacepressure.Forfactory-fittedcylinderaccessories,sensors,etc.pleaserefertothecompleteordercodekeyonpages78-8�.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – L 0 8 0 M C – 0 2 0 0

Cylinder version

L Standardwithlockunit

D Cleanwithlockunit

4 Standardwithlockunitand factoryfittedvalve

Har

dch

rom

e

plat

eds

teel

Har

dch

r.pl

.st

ainl

ess

stee

l

Material Seals Piston rod

C R Standard-�0°Cto+80°C.

2,0

1,5

1,0

0,50,4

0,3

0,2

0,10,5 1 2 3 5 10 20 30 50 100 200

Ø32 Ø40 Ø50 Ø63 Ø80Ø100

Ø125

Use as a brakeThetableshowsthemaximumvaluesforspeedandbrakingmassifthecylinderisusedasabrake.Thecylindershouldnotbeexposedtoadditionalcompressiveforcesasthissignificantlyreducestheexternalmassthatcanbebraked.Werecommendsystemsolutionsasshownatthetopofpage46(Fasteninginposition)orsimilar,inwhichthecylinderdoesnotactasamotorduringbraking.Heatisgener-atedifthebrakeisusedfrequently,andthismustbetakenintoaccounttoensurethatthemaximumtempera-tureisnotexceeded.

Speed [m/s]

Mass [Kg]

Page 50: Parker P1D Series Actuators

50

08.01

www.parker.com/euro_pneumatic

P1D Pistonrodlocking

Fastening in position

Function on hose rupture

Function on pressure loss

Thisistheoptimumsolutionforstraightforwardfasteninginanyposition,whilepreservingthemaximumexpectedservicelifeofthelock.Thecylinderissuppliedwithcompressedairviaa5/3valvewithventedcentre.Thevalveissuppliedwithfullpressureinport3,port�isconnectedtotheminusportonthecylinder,port5issuppliedwithareducedpressureandport4isconnectedtotheplusportonthecylinder.Thereducedpressuretothecylinderplusportistoequalisetheforce,sothatnoforcescanactonthelockwhenitinthelockedposition.Thesolenoidvalvesofthe5/3valvearesuppliedwithcompressedairfroma3/�valve,whichalsosuppliescompressedairtoreleasethelock.Tocausethecylindertomoveineitherdirection,the3/�mustbeactuatedinordertoreleasethelockandsupplythesolenoidvalveswithsignalair,afterwhichtheycanbeactuated.Thismeansthatassoonasthe3/�valveisdeactuated,thelockisappliedandnosignalairissuppliedtothesolenoidvalves,causingthe5/3valvetoswitchtothecentreposition.Thecylinderisnowsuppliedbythetwodifferentpressuresources,isfullyventedandnoforceisappliedtothelock.

Thisarrangementhelpstosecurethepistonrodifthereisapressurelossduetohoserupture.Thecylinderissuppliedbya5/�valveandthecylinderspeediscontrolledusingflowcontrolvalveswithby-passfittednearthecylinder.ATEEpieceisfittedinthepipebetweentheworkingvalveandthecylinder,goingtoachangeovervalvewithairpassingtothelock.Intheeventofapressureloss,thepressuretothe5/�valveceases,asdoesthepressureviathechangeovervalvetothelock.Thelockisthenapplied.

Thissolutionisusedtolockthecylinderintheeventofapressurelossinthesystem.ATEEpieceisfittedinthepipefeedingtheworkingvalveforthecylinder.ThelockonthecylinderissuppliedfromthisTEEpiece.Intheeventofapres-sureloss,thelockisventedimmediatelyandisapplied.

Page 51: Parker P1D Series Actuators

51

08.01

www.parker.com/euro_pneumatic

P1D Pistonrodlocking

AM

ØB

ØD

KK

BG

WH

L12

ØD

4

PP

PL

SS

TT Ø

BA

VA

G

H

P

L

L8 + S

RT

TR

E

DIN 439B

SW

EE

VD G1/8A

6

(M5

Ø32

- Ø

40)

(G1/

8 Ø

50 -

Ø12

5)

DimensionsCylinderbore A AM B BA BG D D4 E EE G H KK Lmm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 18,5 �� 30 30 16 1� 45,0 50,0 G1/8 �8,5 71,0 M10x1,�5 53,0 40 �0,0 �4 35 35 16 16 5�,0 57,4 G1/4 33,0 76,5 M1�x1,�5 56,0 50 �1,0 3� 40 40 16 �0 60,7 69,4 G1/4 33,5 80,0 M16x1,5 65,0 63 30,0 3� 45 45 16 �0 71,5 8�,4 G3/8 39,5 96,0 M16x1,5 76,5 80 35,0 40 45 45 17 �5 86,7 99,4 G3/8 39,5 110,0 M�0x1,5 89,0100 54,0 40 55 55 17 �5 106,7 116,0 G1/� 44,5 13�,0 M�0x1,5 11�,01�5 65,5 54 60 60 �0 3� 134,0 139,0 G1/� 51,0 144,5 M�7x� 1�4,5

Cylinderbore L8 L1� P PL PP R RT SS SW T TT VA VD WHmm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 137 6,0 63,0 13,0 �1,8 3�,5 M6 4,0 10 4,5 4,5 3,5 4,5 15 40 149 6,5 67,5 14,0 �1,9 38,0 M6 8,0 13 3,0 5,5 3,5 4,5 16 50 153 8,0 71,0 14,0 �3,0 46,5 M8 4,0 17 5,5 7,5 3,5 5,0 17 63 178 8,0 87,0 16,4 �7,4 56,5 M8 6,5 17 3,0 11,0 3,5 5,0 17 80 199 10,0 101,0 16,0 30,5 7�,0 M10 0 �� 6,0 15,0 3,5 4,0 �0100 ��6 14,0 1��,0 18,0 35,8 89,0 M10 0 �� 6,0 �0,0 3,5 4,0 �01�5 �54 18,0 134,5 �8,0 40,5 110,0 M1� 0 �7 6,0 17,5 5,5 6,0 �7S=Stroke

TolerancesCylinderbore B BA L8 L9 R Stroketolerance Stroketolerancemm mm mm mm mm uptostroke500mm forstrokeover500mm

3� d11 d11 ±0,4 ±� ±0,5 +0,3/+�,0 +0,3/+3,0 40 d11 d11 ±0,7 ±� ±0,5 +0,3/+�,0 +0,3/+3,0 50 d11 d11 ±0,7 ±� ±0,6 +0,3/+�,0 +0,3/+3,0 63 d11 d11 ±0,8 ±� ±0,7 +0,3/+�,0 +0,3/+3,0 80 d11 d11 ±0,8 ±3 ±0,7 +0,3/+�,0 +0,3/+3,0100 d11 d11 ±1,0 ±3 ±0,7 +0,3/+�,0 +0,3/+3,01�5 d11 d11 ±1,0 ±3 ±1,1 +0,3/+�,0 +0,3/+3,0

CAD drawings on the InternetOurhomepagewww.parker.com/euro_pneumaticincludestheAirCadDrawingLibrarywith�Dand3Ddrawingsforthemainversions.

Page 52: Parker P1D Series Actuators

5�

08.01

www.parker.com/euro_pneumatic

P1D RodGuidanceModules

P1D with rod guidance modulesTheP1Dseriescylinderscanbeequippedwithanexternalguidingdevicetopreventthepistonrodfromturning.Thefactoryfittedguidegivesaguidedpistonmovementandenablesthecylindertotakeupturningmomentsonthepistonrod,aswellasgreatertransverseforces.TherodguidanceisavailablewithplainbearingsorlinearballbearingsandwithHorUstyle.Thebracket,whichhaspre-drilledmountingholes,isconnectedtothepistonrodbymeansofaflexofitting,whichpreventsthebuild-upofstressesinthecylinder.P1Dcylinderswithguidingdeviceareavailablewithboresfrom3�to100mm,andstandardstrokelengthsfrom�5to�50mm.Specialstrokelengthsupto500mmcanalsobeobtained.Factory-fittingoftheguidingdevicecanbespecifiedaccordingtotheorderkeyonpage30.Separateguidingdevicekitscanbesuppliedonrequestaccordingtotheorderkeybelow.

Technical dataLoad Seediagramonpage36Workingmedium Dry,filteredcompressedairWorkingtemperature –�0°Cto+80°C

Material specifications, guidance modulesBody AnodisedaluminiumGuidebars,Hstyle Stainlesssteelforballbearing chromeplatedforplainbearingFrontplate AnodisedaluminiumGuidebars,Ustyle StainlesssteelFrontplate Zinc-platedsteelBearings Plainbearings Linearballbearings

Otherdataasstandardcylinder.

Order specifications for complete unit, please refer to pages 30 and 80

Order key for separate guidance module

Bore size mm

K 3�

L 40

M 50

N 63

P 80

Q 100

Cylinder version

E ISO6431/VDMAcylinders

P 1 E - 4 K R H - 0 1 0 0

Guide module type

H Hstyle,ballbearings

J Hstyle,plainbearings

K Ustyle,plainbearings

Stroke length (mm)

Sameasforthecylindere.g.0100=100mm.

Flange compatible with3D product range.

Self aligning adaptorfor ISO cylinder pistonrod.

Cylinder mountingconforms to ISO 6431and DIN 24335standard

Lubrication points.

Anti-rotation achieved by 4 integral bearings. Choice of linear ball bearings or plain PTFE coated bearings

Aluminium body provides 3 mounting faces.

Guide bars:Ball bearing versionsstainless steel.Plain bearing versionhard chrome plated.

Installation on P1D with lock unitIf rotary control is to be retrofitted to a P1D with lock unit, the piston rod must be extended to provide the same WH dimensions as for the P1D base cylinder, as shown in the table below.

Cyl.dim Pistonrodextension onP1Dwithlockunitmm mm

3� 11 40 14 50 �0 63 �0 80 �6100 31

Ball bearings are greased for life, for extra protection external wiper seals are fitted on each face of the unit.

Page 53: Parker P1D Series Actuators

53

08.01

www.parker.com/euro_pneumatic

P1D RodGuidanceModules

Technical information 'H style'

Maximum permissible torque (Nm)

Stroke(mm)

Maximum permissible torque (Nm)

Stroke(mm)

F

L

Formula:

C(Nm)=F(N)xL(m)

Load (kg)

Stroke(mm)

Maximum load carried

Stroke(mm)

Deflection(mm)

Maximum deflection/max load Maximum deflection/max load

Stroke(mm)

Maximum load carriedLoad (kg)

Stroke(mm)

Deflection(mm)

C

f

A2 / 2

A2

Graphsestablishedatmidpointofstroke

A2 / 2

A2

C

Graphsestablishedatmidpointofstroke

Rod guide with ball bearingsRod guide with plain bearings

60

1

2

3

45

10

15

20

304050

025

5080

125160

200250

320400

500

Ø80 & 100

Ø63Ø50

Ø40

Ø32

60

0,5

1

2

345

10

15

20

30

4050

025

5080

125160

200250

320400

500

Ø80 & 100

Ø63Ø50

Ø40

Ø32

025

5080

125160

200250

320400

500

Ø40 & 63 & 100Ø50 & 80

Ø32

0,2

0,1

0,4

0,60,8

1,5

3,0

6,0

8,0

10,0

025

5080

125160

200250

320400

500

Ø63 & 100

Ø50 & 80Ø32 & 40

0,2

0,4

0,6

0,8

1,0

1,2

1,4

025

5080 125

160200

250320

400100500

Ø100Ø80

Ø63Ø50Ø40 Ø322

468

10

15

20

25

30

35

40

025

5080 125

160200

250320

400100500

Ø100

Ø80

Ø63Ø50Ø40Ø322

468

10

15

20

25

30

35

40

45

50

55

Torque(Nm)

Torque(Nm)

Page 54: Parker P1D Series Actuators

54

08.01

www.parker.com/euro_pneumatic

B4

2 x Ø6H7

B1

A1B

5

B4

B3

B2

A2

B4

P1 P2

D5

ØD

1

ØD

2

E1

B6

B4

L2 B7

C3

C2

K2

K1

H2

L5 ***L4

*

G1

R1

ØC

1

R2

N1 **

V

L1 + S

L3 + S

H1

B8

ØF

1

P3

B4

D5 depth T

P1D RodGuidanceModules

Dimensions, H style guidance modulesCyl.bore A1 A� B1 B� B3 B4 B5 B6 B7 B8 ØC1 C� C3 ØD1 ØD� D5mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 50 97 45 90 78 3�,5 50 4,0 1� 61 1� 73,5 50 6,6 11 M6 40 58 115 54 110 84 38,0 54 11,0 1� 69 16 86,5 58 6,6 11 M6 50 70 137 63 130 100 46,5 7� 19,0 15 85 �0 103,5 70 9,0 14 M8 63 85 15� 80 145 105 56,5 8� 15,0 15 100 �0 118,5 85 9,0 14 M8 80 105 189 100 180 130 7�,0 106 �1,0 �0 130 �5 147,0 105 11,0 17 M10100 130 �13 1�0 �00 150 89,0 131 �4,5 �0 150 �5 171,5 130 11,0 17 M10

Cyl.bore E1 ØF1+0,1/0 G1 L1 L� L3 L4 L5 N1 P1

±1 P�±1 P3 R1 R� W

mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 7 30 17 150 1�0 15 71 64 17 36 31 40 M6 11 5 40 7 35 �4 170 130 �5 71 74 17 36 36 44 M6 11 6 50 9 40 �7 19� 150 �4 79 89 �4 4� 44 50 M8 16 8 63 9 45 �7 ��� 180 �4 109 89 �4 58 44 60 M8 16 8 80 11 45 3� �47 �00 �4 113 110 30 50 5� 70 M10 16 10100 11 55 3� �67 ��0 �4 1�8 115 30 49 51 70 M10 16 10

Cyl.bore H1±0,05 H� K1

H8 K� T V+0,3/0 Weightat0mmstroke Supplementweightper10mmstrokemm mm mm mm mm mm mm kg kg

3� 81 11,7 �4 19 1� 4 0,970 0,018 40 99 8,0 �4 19 1� 4 1,550 0,315 50 119 4,� 38 �6 16 4 �,560 0,493 63 13� 13,0 38 �6 16 4 3,570 0,493 80 166 15,0 46 3� �0 4 6,530 0,770100 190 �0,5 46 3� �0 4 8,760 0,770

S=Strokelength

* 6holeØ6H7,depth10+1/0

** Hexagonprofile*** Minadjustment=0,max.=W

Page 55: Parker P1D Series Actuators

55

08.01

www.parker.com/euro_pneumatic

P1D RodGuidanceModules

B4

B4

2 x Ø6H7

B1

A1

B5

B4

B4

B3

B2

A2

L3 + S

L1 + S

L2

B6B4

N1**

G1

B7H2

L4 L5***

C2

C3

ØF

1

H1

R1 Ø

C1

ØD

1

ØD

2

B8

D5

R2

E2

*

Dimensions, U style guidance modulesCyl.bore. A1 A� B1 B� B3 B4 B5 B6 B7 B8 C1 C� C3 D1 D� D5mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 50 97 45 90 78 3�,5 50 18,0 1� 61 1� 73,5 50 6,6 11 M6 40 58 115 54 110 84 38,0 54 15,5 1� 70 16 86,5 58 6,6 11 M6 50 70 137 63 130 100 46,5 7� 19,5 15 85 �0 103,5 70 9,0 14 M8 63 85 15� 80 145 105 56,5 8� �9,5 15 100 �0 118,5 85 9,0 14 M8 80 105 189 100 180 130 7�,0 106 39,0 �0 130 �5 147,0 105 11,0 17 M10100 130 �13 1�0 �00 150 89,0 131 53,0 �0 150 �5 171,5 130 11,0 17 M10

Cyl.bore E1 E� ØF1+0,1/0 G1 L1 L� L3 L4 L5 N1 R1 R� H1

±0,05 H� Wmm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 1� 7 30 30 134 7� 15,0 44 75,0 17 M6 61 1,75 � 40 1� 7 35 36 150 84 13,0 51 86,0 17 M8 70 3,50 � 50 16 9 40 4� 175 100 1�,0 60 103,0 �4 M8 85 3,75 4 63 16 9 45 4� 190 115 1�,0 75 103,0 �4 M8 100 1,�5 4 80 16 11 45 49 �38 160 1,0 111 1�6,0 30 M10 130 3,�5 6100 16 11 55 49 �49 165 7,5 110 131,5 30 M10 150 8,50 6

Cyl.bore Weightat0mmstroke Supplementweightper10mmstrokemm kg kg

3� 0,970 0,018 40 1,550 0,315 50 �,560 0,493 63 3,570 0,493 80 6,530 0,770100 8,760 0,770

S=Strokelength

* 6holeØ6H7,depth10+1/0

** Hexagonprofile*** Minadjustment=0,max.=W

12 x D5 depth E1

Page 56: Parker P1D Series Actuators

56

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Flange MF1/MF2 Intendedforfixedmountingofcylinder.Flangecanbefittedtofrontorrearendcoverofcylinder.MaterialsFlange:Surface-treatedsteel,blackMountingscrewsacc.toDIN691�:Zinc-platedsteel8.8Suppliedcompletewithmountingscrewsforattachmenttocylinder.

AccordingtoISOMF1/MF�,VDMA�456�,AFNOR

Cyl. d1 FB TG1 E R MF TF UF l1 W* ZF* ZB*bore H11 H13 JS14 JS14 JS14 -0,5mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 30 7 3�,5 45 3� 10 64 80 5,0 16 130 1�3,5 40 35 9 38,0 5� 36 10 7� 90 5,0 �0 145 138,5 50 40 9 46,5 65 45 1� 90 110 6,5 �5 155 146,5 63 45 9 56,5 75 50 1� 100 1�0 6,5 �5 170 161,5 80 45 1� 7�,0 95 63 16 1�6 150 8,0 30 190 177,5100 55 14 89,0 115 75 16 150 170 8,0 35 �05 19�,51�5 60 16 110,0 140 90 �0 180 �05 10,5 45 �45 �30,5S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Foot bracket MS1 Intendedforfixedmountingofcylinder.Footbracketcanbefittedtofrontandrearendcoversofcylinder.MaterialsFootbracket:Surface-treatedsteel,blackMountingscrewsacc.toDIN91�:Zinc-platedsteel8.8Suppliedinpairswithmountingscrewsforattachmenttocylinder.

AccordingtoISOMS1,VDMA�456�,AFNOR

Cyl. AB TG1 E TR AO AU AH l7 AT l9 SA*bore H14 JS14 JS15 JS14mm mm mm mm mm mm mm mm mm mm mm mm

3� 7 3�,5 45 3� 10 �4 3� 30 4,5 17,0 14� 40 9 38,0 5� 36 8 �8 36 30 4,5 18,5 161 50 9 46,5 65 45 13 3� 45 36 5,5 �5,0 170 63 9 56,5 75 50 13 3� 50 35 5,5 �7,5 185 80 1� 7�,0 95 63 14 41 63 49 6,5 40,5 �10100 14 89,0 115 75 15 41 71 54 6,5 43,5 ��01�5 16 110,0 140 90 �� 45 90 71 8,0 60,0 �50

S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Pivot bracket with Intendedforflexiblemountingofcylinder.The rigid bearing pivotbracketcanbecombinedwithclevisbracketMP�.

MaterialsPivotbracket:Surface-treatedaluminium,blackBearing:Sinteredoil-bronzebushing

AccordingtoCETOPRP107P,VDMA�456�,AFNOR

Cyl. CK S5 K1 K� G1 G� EM G3 CA H6 R1bore H9 H13 JS14 JS14 JS14 JS15mm mm mm mm mm mm mm mm mm mm mm mm

3� 10 6,6 38 51 �1 18 �5,5 31 3� 8 10,0 40 1� 6,6 41 54 �4 �� �7,0 35 36 10 11,0 50 1� 9,0 50 65 33 30 31,0 45 45 1� 13,0 63 16 9,0 5� 67 37 35 39,0 50 50 1� 15,0 80 16 11,0 66 86 47 40 49,0 60 63 14 15,0100 �0 11,0 76 96 55 50 59,0 70 71 15 19,01�5 �5 14,0 94 1�4 70 60 69,0 90 90 �0 ��,5

3� 0,�3 P1C-4KMB 40 0,�8 P1C-4LMB 50 0,53 P1C-4MMB 63 0,71 P1C-4NMB 80 1,59 P1C-4PMB100 �,19 P1C-4QMB1�5 3,78 P1C-4RMB

ØF

B

R

UF

Ød1 TF

E

TG1

ZB+S

MFMF

W

ZF+S

I1

5

G

ØC

K

CA

G2

G3

1R1

H6

KK12

EM

SA+S

ØAB

AU AO

AT

E

TGI

IAH

TR7

3� 0,06** P1C-4KMF 40 0,08** P1C-4LMF 50 0,16** P1C-4MMF 63 0,�5** P1C-4NMF 80 0,50** P1C-4PMF100 0,85** P1C-4QMF1�5 1,48** P1C-4RMF

**Weightperitem

3� 0,06 P1C-4KMD 40 0,08 P1C-4LMD 50 0,15 P1C-4MMD 63 0,�0 P1C-4NMD 80 0,33 P1C-4PMD100 0,49 P1C-4QMD1�5 1,0� P1C-4RMD

Cylinder mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Page 57: Parker P1D Series Actuators

57

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Swivel eye bracket IntendedforusetogetherwithclevisbracketGAMaterialBracket:Surface-treatedaluminium,blackSwivelbearingacc.toDIN648K:HardenedsteelSuppliedcompletewithmountingscrewsforattachmenttocylinder.

AccordingtoVDMA�456�,AFNOR

Cyl. E B1 B� EN R1 R� FL l� L CN XD* Zbore H7 mm mm mm mm mm mm mm mm mm mm mm mm

3� 45 10,5 - 14 16 - �� 5,5 1� 10 14� 4° 40 5� 1�,0 - 16 18 - �5 5,5 15 1� 160 4° 50 65 15,0 51 �1 �1 19 �7 6,5 15 16 170 4° 63 75 15,0 - �1 �3 - 3� 6,5 �0 16 190 4° 80 95 18,0 - �5 �9 - 36 10,0 �0 �0 �10 4°100 115 18,0 - �5 31 - 41 10,0 �5 �0 �30 4°1�5 140 �5,0 - 37 40 - 50 10,0 30 30 �75 4°S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Clevis bracket MP2 Intendedforflexiblemountingofcylinder.ClevisbracketMP�canbecombinedwithclevisbracketMP4.MaterialsClevisbracket:Surface-treatedaluminium,blackPin:SurfacehardenedsteelCirclipsaccordingtoDIN471:SpringsteelMountingscrewsacc.toDIN91�:Zinc-platedsteel8.8Suppliedcompletewithmountingscrewsforattachmenttocylinder.

AccordingtoISOMP�,VDMA�456�,AFNOR

Cyl. C E UB CB FL L l� CD MR XD*bore h14 H14 ±0,� H9 mm mm mm mm mm mm mm mm mm mm mm

3� 53 45 45 �6 �� 13 5,5 10 10 14� 40 60 5� 5� �8 �5 16 5,5 1� 1� 160 50 68 65 60 3� �7 16 6,5 1� 1� 170 63 78 75 70 40 3� �1 6,5 16 16 190 80 98 95 90 50 36 �� 10,0 16 16 �10100 118 115 110 60 41 �7 10,0 �0 �0 �301�5 139 140 130 70 50 30 10,0 �5 �5 �75S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

3� 0,08 P1C-4KMSA 40 0,11 P1C-4LMSA 50 0,�0 P1C-4MMSA 63 0,�7 P1C-4NMSA 80 0,5� P1C-4PMSA100 0,7� P1C-4QMSA1�5 1,53 P1C-4RMSA

3� 0,08 P1C-4KMT 40 0,11 P1C-4LMT 50 0,14 P1C-4MMT 63 0,�9 P1C-4NMT 80 0,36 P1C-4PMT100 0,64 P1C-4QMT1�5 1,17 P1C-4RMT

UB

CB

E

XD+S

MR

I

FL

L

2

C

XD+S

ØCN

R1

L

R2

B

B1

2

EN

L2FL

ZZ

Cylinder mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Formountingscrewsinstainlesssteelseepage65.

Page 58: Parker P1D Series Actuators

58

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Clevis bracket MP4 Intendedforflexiblemountingofcylinder.ClevisbracketMP4canbecombinedwithclevisbracketMP�.MaterialsClevisbracket:Surface-treatedaluminium,blackMountingscrewsacc.toDIN91�:Zinc-platedsteel8.8Suppliedcompletewithmountingscrewsforattachmenttocylinder.

AccordingtoISOMP4,VDMA�456�,AFNOR

Cyl. E EW FL L l� CD MR XD*bore ±0,� H9mm mm mm mm mm mm mm mm mm

3� 45 �6 �� 13 5,5 10 10 14� 40 5� �8 �5 16 5,5 1� 1� 160 50 65 3� �7 16 6,5 1� 1� 170 63 75 40 3� �1 6,5 16 16 190 80 95 50 36 �� 10,0 16 16 �10100 115 60 41 �7 10,0 �0 �0 �301�5 140 70 50 30 10,0 �5 �5 �75S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Clevis bracket GA Intendedforflexiblemountingofcylinder.ClevisbracketGAcanbecombinedwithpivotbracketwithswivelbearing,swiveleyebracketandswivelrodeye.MaterialsClevisbracket:Surface-treatedaluminiumPin:SurfacehardenedsteelLockingpin:SpringsteelCirclipsaccordingtoDIN471:SpringsteelMountingscrewsacc.toDIN91�:Zinc-platedsteel8.8Suppliedcompletewithmountingscrewsforattachmenttocylinder.

AccordingtoVDMA�456�,AFNOR

Cyl. C E B� B1 T B3 R� L1 FL l� L CN R1 XD*bore d1� H14 ±0,� F7mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 41 45 34 14 3 3,3 17 11,5 �� 5,5 1� 10 11 14� 40 48 5� 40 16 4 4,3 �0 1�,0 �5 5,5 15 1� 13 160 50 54 65 45 �1 4 4,3 �� 14,0 �7 6,5 17 16 18 170 63 60 75 51 �1 4 4,3 �5 14,0 3� 6,5 �0 16 18 190 80 75 95 65 �5 4 4,3 30 16,0 36 10,0 �0 �0 �� �10100 85 115 75 �5 4 4,3 3� 16,0 41 10,0 �5 �0 �� �301�5 110 140 97 37 6 6,3 4� �4,0 50 10,0 30 30 30 �75S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

3� 0,09 P1C-4KMCA 40 0,13 P1C-4LMCA 50 0,17 P1C-4MMCA 63 0,36 P1C-4NMCA 80 0,58 P1C-4PMCA100 0,89 P1C-4QMCA1�5 1,75 P1C-4RMCA

EW

E

XD+S

CD

MR

I

FL

L

2

3� 0,09 P1C-4KME 40 0,13 P1C-4LME 50 0,17 P1C-4MME 63 0,36 P1C-4NME 80 0,46 P1C-4PME100 0,83 P1C-4QME1�5 1,53 P1C-4RME

Stainless steel Pin Set GAMaterialsPin:StainlesssteelLockingpin:StainlesssteelCirclipsaccordingtoDIN471:Stainlesssteel 3� 0,05 9301054311 40 0,06 9301054312 50 0,07 9301054313 63 0,07 9301054314 80 0,17 9301054315100 0,31 93010543161�5 0,54 9301054317

XD+S

CN

R1

L

L

R2

B

B

E

1

2

B3

T1

L2FL

C

Formountingscrewsinstainlesssteelseepage65.

Cylinder mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Page 59: Parker P1D Series Actuators

59

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Pivot bracket with IntendedforusetogetherwithclevisbracketGA.swivel bearing

MaterialPivotbracket:Surface-treatedsteel,blackSwivelbearingacc.toDIN648K:Hardenedsteel

AccordingtoVDMA�456�,AFNOR

Cyl. CN S5 K1 K� EU G1 G� EN G3 CH H6 ER Zbore H7 H13 JS14 JS14 JS14 JS15mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 10 6,6 38 51 10,5 �1 18 14 31 3� 10 16 4° 40 1� 6,6 41 54 1�,0 �4 �� 16 35 36 10 18 4° 50 16 9,0 50 65 15,0 33 30 �1 45 45 1� �1 4° 63 16 9,0 5� 67 15,0 37 35 �1 50 50 1� �3 4° 80 �0 11,0 66 86 18,0 47 40 �5 60 63 14 �8 4°100 �0 11,0 76 96 18,0 55 50 �5 70 71 15 30 4°1�5 30 14,0 94 1�4 �5,0 70 60 37 90 90 �0 40 4°

Mounting kit Mountingkitforbacktobackmountedcylinders,3and4positioncylinders.Material:Mounting:AluminiumMountingscrews:Zinc-platedsteel8.8

Cyl. E TG ØFB MF A ØBAboremm mm mm mm mm mm mm

3� 50 3�,5 6,5 5 16 30 40 60 38,0 6,5 5 16 35 50 66 46,5 8,5 6 �0 40 63 80 56,5 8,5 6 �0 45 80 100 7�,0 10,5 8 �5 45100 118 89,0 10,5 8 �5 55

Pivot bracket for MT4 IntendedforusetogetherwithcentretrunnionMT4.MaterialPivotbracket:Surface-treatedaluminiumBearingacc.toDIN1850C:Sinteredoil-bronzebushingSuppliedinpairs.

AccordingtoISO,VDMA�456�,AFNOR

Cyl. B1 B� A C d1 d� H1 H� fx45°bore H13 minmm mm mm mm mm mm mm mm mm mm

3� 46 18,0 3� 10,5 1� 6,6 30 15 1,0 40 55 �1,0 36 1�,0 16 9,0 36 18 1,6 50 55 �1,0 36 1�,0 16 9,0 36 18 1,6 63 65 �3,0 4� 13,0 �0 11,0 40 �0 1,6 80 65 �3,0 4� 13,0 �0 11,0 40 �0 1,6100 75 �8,5 50 16,0 �5 14,0 50 �5 �,01�5 75 �8,5 50 16,0 �5 14,0 50 �5 �,0

5

G

ØC

N

CH

G2

G3

1ER

H6

KK12

EU

ZZ

EN

E

TG

ØFB

ETG

A

MF

ØBA

3� 0,04* 9301054261 40 0,07* 9301054262 50 0,07* 9301054262 63 0,1�* 9301054264 80 0,1�* 9301054264100 0,�1* 93010542661�5 0,�1* 9301054266

*Weightperitem.

3� 0,18 P1C-4KMA 40 0,�5 P1C-4LMA 50 0,47 P1C-4MMA 63 0,57 P1C-4NMA 80 1,05 P1C-4PMA100 1,4� P1C-4QMA1�5 3,10 P1C-4RMA

3� 0,060 P1E-6KB0 40 0,078 P1E-6LB0 50 0,16� P1E-6MB0 63 0,194 P1E-6NB0 80 0,450 P1E-6PB0100 0,67� P1E-6QB0

C

B2

fx45°

H2

Ød1

H1

AB1

Ød2

Cylinder mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Page 60: Parker P1D Series Actuators

60

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Flange mounted trunnion Intendedforarticulatedmountingofcylinder.ThistrunnioncanbeflangemountedonthefrontorrearendcoverofallP1Dcylinders.Atyourchoice,youcanorderacompletecylinderwithfactory-fittedflangemountedtrunnion–seetheordercodekeyatpages31and80-8�.Individualtrunnionshaveordercodeasshowntotheright.Material:Trunnion:zincplatedsteelScrews:zincplatedsteel,8.8Deliveredcompletewithmountingscrewsforattachmenttothecylinder

AccordingtoISOMT4,VDMA�456�,AFNOR

Cyl. TM TL TD R UW L1 XV1* X* Ybore h14 h14 e9mm mm mm mm mm mm mm mm mm mm

3� 50 1� 1� 1,0 46 14 19,5 1�6,5 11 40 63 16 16 1,6 59 19 �1,0 144,0 14 50 75 16 16 1,6 69 19 �8,0 15�,0 �0 63 90 �0 �0 1,6 84 �4 �5,5 169,5 �0 80 110 �0 �0 1,6 10� �4 34,5 185,5 �6100 13� �5 �5 �,0 1�5 �9 37,0 �03,0 31XV�=X+Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

TofitaflangemountedtrunnionatthefrontendcoverofaP1Dcylinderwithlockunit,thepistonrodmustbeextended.ThisisinordertoprovidethesameWHdimensionsasfortheP1DbasecylinderwithdimensionY.

3� 0,13 See order 40 0,31 key on 50 0,37 pages 63 0,69 31 and 80 0,89 80-82100 1,581�5 �,60

TL

UW

TM

TD

TL

R

XVstd

L1LL

XVmin

XVmax

3� 0,17 P1D-4KMYF 40 0,43 P1D-4LMYF 50 0,55 P1D-4MMYF 63 1,10 P1D-4NMYF 80 1,66 P1D-4PMYF100 3,00 P1D-4QMYF

TL

UW

TM

TD

TL

R

XV1

L1LL

XV2

L1LL

Cylinder mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Centre trunnion MT4 Intendedforarticulatedmountingofcylinder.Thismountingfor P1D-S isavailablefortheP1DStandardandforthetie-rod

designofP1D.Thetrunnionisfactory-fittedinthecentreofthecylinderoratanoptionallocationspecifiedbytheXV-measure–seetheordercodekey.CombinedwithpivotbracketforMT4.Material:Trunnion:zincplatedsteel

Centre trunnion MT4 Trunnion centredfor P1D-T ThecentretrunnionfortheP1D-SandP1D-Tisordered

withletterDinposition17(nodimensionspecifiedinpositions18-�0).Seetheordercodekeyatpages31.

Trunnion with optional locationThecentretrunnionfortheP1D-SandP1D-TisorderedwithletterGinposition17anddesiredXV-measure(3-digitmeasureinmm)inpositions18-�0.Seetheordercodekeyatpage31.

Trunnion loose P1D-Scanalsobeorderedwiththecentretrunnion

looselyfittedtothecylinder(notfixedinposition).Thisallowsthepositiontobeestablishedatthetimeofinstallation.

OrderedwithletterGinposition17and000inpositions18-�0.Pleaserefertotheordercodekeyonpage31.

AccordingtoISOMT4,VDMA�456�,AFNOR

Cyl. TM TL TD R UW UW L1 L1 X1* XVmin XVmin XVmin X� X� X�bore h14 h14 e9 P1D-S P1D-T P1D-S P1D-T P1D-S P1D-T P1D-L P1D-S P1D-T P1D-Lmm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 50 1� 1� 1,0 5� 46 18 15 73,0 89 6� 1�1 57 84 88 40 63 16 16 1,6 59 59 �0 �0 8�,5 95 73 1�5 70 9� 99 50 75 16 16 1,6 71 69 �0 �0 90,0 113 81 140 67 99 93 63 90 �0 �0 1,6 84 84 �6 �5 97,5 118 89 155 78 106 114 80 110 �0 �0 1,6 105 10� �6 �5 110,0 13� 98 177 88 1�� 13�100 13� �5 �5 �,0 1�9 1�5 3� 30 1�0,0 140 111 197 100 1�9 1561�5 160 �5 �5 �,0 159 155 33 3� 145,0 168 13� ��4 1�� 158 177

XVstd=X1+Strokelength/�,XVmax=X�+Strokelength8

Page 61: Parker P1D Series Actuators

61

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Swivel rod eye Swivelrodeyeforarticulatedmountingofcylinder.SwivelrodeyecanbecombinedwithclevisbracketGA.Maintenance-free.MaterialsSwivelrodeye:Zinc-platedsteelSwivelbearingaccordingtoDIN648K:Hardenedsteel

Stainless steel swivel rod eye Stainless-steelswivelrodeyeforarticulatedmountingofcylinder.SwivelrodeyecanbecombinedwithclevisbracketGA.Maintenance-free.MaterialsSwivelrodeye:StainlesssteelSwivelbearingaccordingtoDIN648K:StainlesssteelUsestainlesssteelnut(seepage6�)withstainlesssteelswivelrodeye.

AccordingtoISO8139

Cyl. A B B CE CN EN ER KK LE N O Zbore min max H9 h1� minmm mm mm mm mm mm mm mm mm mm mm

3� �0 48,0 55 43 10 14 14 M10x1,�5 15 17 10,5 1�° 40 �� 56,0 6� 50 1� 16 16 M1�x1,�5 17 19 1�,0 1�° 50 �8 7�,0 80 64 16 �1 �1 M16x1,5 �� �� 15,0 15° 63 �8 7�,0 80 64 16 �1 �1 M16x1,5 �� �� 15,0 15° 80 33 87,0 97 77 �0 �5 �5 M�0x1,5 �6 3� 18,0 15°100 33 87,0 97 77 �0 �5 �5 M�0x1,5 �6 3� 18,0 15°1�5 51 1�3,5 137 110 30 37 35 M�7x� 36 41 �5,0 15°

Clevis Clevisforarticulatedmountingofcylinder.MaterialClevis,clip:GalvanizedsteelPin:Hardenedsteel

Stainless steel clevis Stainless-steelclevisforarticulatedmountingofcylinder.MaterialClevis:StainlesssteelPin:StainlesssteelCirclipsaccordingtoDIN471:StainlesssteelUsestainlesssteelnut(seepage6�)withstainlesssteelswivelrodeye.

AccordingtoISO8140

Cyl. A B B CE CK CL CM ER KK LE Obore min max h11/E9mm mm mm mm mm mm mm mm mm mm mm

3� �0 45,0 5� 40 10 �0 10 16 M10x1,�5 �0 �8,0 40 �4 54,0 60 48 1� �4 1� 19 M1�x1,�5 �4 3�,0 50 3� 7�,0 80 64 16 3� 16 �5 M16x1,5 3� 41,5 63 3� 7�,0 80 64 16 3� 16 �5 M16x1,5 3� 41,5 80 40 90,0 100 80 �0 40 �0 3� M�0x1,5 40 50,0100 40 90,0 100 80 �0 40 �0 3� M�0x1,5 40 50,01�5 56 1�3,5 137 110 30 55 30 45 M�7x� 54 7�,0

CK

B

ER

CELEA

CL

CM O

KK

3� 0,08 P1C-4KRS 40 0,1� P1C-4LRS 50 0,�5 P1C-4MRS 63 0,�5 P1C-4MRS 80 0,46 P1C-4PRS100 0,46 P1C-4PRS1�5 1,�8 P1C-4RRS

3� 0,08 P1S-4JRT 40 0,1� P1S-4LRT 50 0,�5 P1S-4MRT 63 0,�5 P1S-4MRT 80 0,46 P1S-4PRT100 0,46 P1S-4PRT1�5 1,�8 P1S-4RRT

3� 0,09 P1C-4KRC 40 0,15 P1C-4LRC 50 0,35 P1C-4MRC 63 0,35 P1C-4MRC 80 0,75 P1C-4PRC100 0,75 P1C-4PRC1�5 �,10 P1C-4RRC

3� 0,09 P1S-4JRD 40 0,15 P1S-4LRD 50 0,35 P1S-4MRD 63 0,35 P1S-4MRD 80 0,75 P1S-4PRD100 0,75 P1S-4PRD1�5 �,10 P1S-4RRD

CN

B

N

Z

ACE

LE

O

KK

EN

ER

Z

Piston rod mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Page 62: Parker P1D Series Actuators

6�

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Flexo coupling Flexocouplingforarticulatedmountingofpistonrod.Flexofittingisintendedtotakeupaxialangleerrorswithinarangeof±4°.MaterialFlexocoupling,nut:Zinc-platedsteelSocket:HardenedsteelSuppliedcompletewithgalvanizedadjustmentnut.

Cyl. B B DL EH EI EK EL EN EO EP EQ ER M Zbore min maxmm mm mm mm mm mm mm mm mm mm mm mm mm

3� 36,0 43 M10x1,�5 �0 �3 70 31 1� 30 30 19 30 5,0 4° 40 37,0 43 M1�x1,�5 �3 �3 67 31 1� 30 30 19 30 6,0 4° 50 53,0 61 M16x1,5 40 3� 11� 45 19 41 41 30 41 8,0 4° 63 53,0 61 M16x1,5 40 3� 11� 45 19 41 41 30 41 8,0 4° 80 57,0 67 M�0x1,5 39 4� 1�� 56 19 41 41 30 41 10,0 4°100 57,0 67 M�0x1,5 39 4� 1�� 56 19 41 41 30 41 10,0 4°1�5 75,5 89 M�7x� 48 48 145 60 �4 55 55 3� 55 13,5 4°

Nut Intendedforfixedmountingofaccessoriestothepistonrod.Material:Zinc-platedsteelAllP1Dcylindersaredelivredwithazinc-platedsteelpistonrodnut,exceptP1DClean,whichisdeliveredwithastainlesssteelpistonrodnutinstead.

Stainless steel nut Intendedforfixedmountingofaccessoriestothepistonrod.Material:StainlesssteelA�AllP1Dcylindersaredelivredwithazinc-platedsteelpistonrodnut,exceptP1DClean,whichisdeliveredwithastainlesssteelpistonrodnutinstead.

Acid-proof nut Intendedforfixedmountingofaccessoriestothepistonrod.Material:Acid-proofsteelA4Cylinderswithacid-proofpistonrodaresuppliedwithnutofacid-proofsteel

AccordingtoDIN439B

Cyl.bore A B Cmm mm mm

3� 17 5,0 M10x1,�5 40 19 6,0 M1�x1,�5 50 �4 8,0 M16x1,5 63 �4 8,0 M16x1,5 80 30 10,0 M�0x1,5100 30 10,0 M�0x1,51�5 41 13,5 M�7x�

DL

ER

Z

M

Z

DL

EN EO EP EQ

EI

EL

B

EK

EH

M

3� 0,�1 P1C-4KRF 40 0,�� P1C-4LRF 50 0,67 P1C-4MRF 63 0,67 P1C-4MRF 80 0,7� P1C-4PRF100 0,7� P1C-4PRF1�5 1,80 P1C-4RRF

A

C B

3� 0,007 9128985601 40 0,010 0261109910 50 0,0�1 9128985603 63 0,0�1 9128985603 80 0,040 0261109911100 0,040 02611099111�5 0,100 0261109912

3� 0,007 9126725404 40 0,010 9126725405 50 0,0�1 9126725406 63 0,0�1 9126725406 80 0,040 0261109921100 0,040 02611099211�5 0,100 0261109922

3� 0,007 0261109919 40 0,010 0261109920 50 0,0�1 0261109917 63 0,0�1 0261109917 80 0,040 0261109916100 0,040 02611099161�5 0,100 0261109918

Piston rod mountingsType Description Cyl.bore Weight Ordercode Ømm kg

Page 63: Parker P1D Series Actuators

63

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Clevis bracket MP4 Clevis bracket MP2 Inthiscombinationtheclevis bracketMP4isattachedtothe cylinder.

Sameasabovebutwithscrews andpininstainlesssteel.Deliveredasindividualmountings,notmountedtogether,andcompletewithmountingscrewsforattachmenttocylinder.

Cyl. A B C CD d3 E FL L TG1 XA* XD* Zbore H9 H13 ±0,�mm mm mm mm mm mm mm mm mm mm mm mm

3� 9 44 53 10 6,6 45 �� 13 3�,5 164 14� 11�° 40 9 50 60 1� 6,6 5� �5 16 38,0 185 160 1��° 50 11 54 68 1� 9,0 65 �7 16 46,5 197 170 94° 63 11 64 78 16 9,0 75 3� �1 56,5 ��� 190 11�° 80 14 7� 98 16 11,0 95 36 �� 7�,0 �46 �10 8�°100 14 8� 118 �0 11,0 115 41 �7 89,0 �71 �30 90°1�5 �0 100 139 �5 13,5 140 50 30 110,0 3�5 �75 94°S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Clevis bracket MP2 Pivot bracket with Inthiscombinationtheclevisrigid bearing bracketMP�isattachedto thecylinder.

Sameasabovebutwithscrews andpininstainlesssteel.

Deliveredasindividualmountings,notmountedtogether,andcompletewithmountingscrewsforattachmenttocylinder.

Cyl. A CA D E G1 G� G3 H6 k1 k� S5 XA* XD* Z1 Z�bore JS15 JS14 JS14 JS14 H13mm mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 43 3� 53 45 �1 18 31 8 38 51 6,6 169,5 14� 150° 18° 40 49 36 60 5� �4 �� 35 10 41 54 6,6 190,5 160 155° 18° 50 60 45 68 65 33 30 45 1� 50 65 9,0 �10,5 170 145° 18° 63 69 50 78 75 37 35 50 1� 5� 67 9,0 �34,5 190 155° �0° 80 83 63 98 95 47 40 60 14 66 86 11,0 �67,0 �10 150° �0°100 96 71 118 115 55 50 70 15 76 96 11,0 �95,0 �30 150° 15°1�5 1�0 90 139 140 70 60 90 �0 94 1�4 14,0 360,0 �75 145° 18°S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

3� 0,17 P1C-4KML 40 0,�4 P1C-4LML 50 0,31 P1C-4MML 63 0,65 P1C-4NML 80 0,8� P1C-4PML100 1,47 P1C-4QML1�5 �,70 P1C-4RML 3� 0,13 P1C-4KMG 40 0,�3 P1C-4LMG 50 0,35 P1C-4MMG 63 0,61 P1C-4NMG 80 0,66 P1C-4PMG100 1,53 P1C-4QMG1�5 �,83 P1C-4RMG

3� 0,14 P1C-4KMP 40 0,19 P1C-4LMP 50 0,�9 P1C-4MMP 63 0,49 P1C-4NMP 80 0,69 P1C-4PMP100 1,13 P1C-4QMP1�5 �,83 P1C-4RMP

3� 0,10 P1C-4KMK 40 0,18 P1C-4LMK 50 0,33 P1C-4MMK 63 0,45 P1C-4NMK 80 0,93 P1C-4PMK100 1,19 P1C-4QMK1�5 �,3� P1C-4RMK

C

E

1

d

XA+S

CD

FL

..

XD+S

Z

XA+S

G1

G

..

XD+S

D

K112

E

S5

CA

H6

A

2

Z2

Z1

CombinationsType Description Cyl.bore Weight Ordercode Ømm kg

Page 64: Parker P1D Series Actuators

64

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Clevis bracket GA Pivot bracket with Inthiscombinationtheclevisswivel bearing bracketGAisattachedtothe cylinder.

Deliveredasindividualmountings,notmountedtogether,andcompletewithmountingscrewsforattachmenttocylinder.

Cyl. CH E ER G1 G� G3 H6 k1 k� l3 S5 XD* Z1 Z� Z3bore JS15 JS14 JS14 JS14 H13mm mm mm mm mm mm mm mm mm mm mm mm mm

3� 3� 45 16 �1 18 31 10 38 51 41 6,6 14� 4° 130° 10° 40 36 5� 18 �4 �� 35 10 41 54 48 6,6 160 4° 140° 15° 50 45 65 �1 33 30 45 1� 50 65 54 9,0 170 4° 130° 8° 63 50 75 �3 37 35 50 1� 5� 67 60 9,0 190 4° 140° �0° 80 63 95 �8 47 40 60 14 66 86 75 11,0 �10 4° 1�5° 4°100 71 115 30 55 50 70 15 76 96 85 11,0 �30 4° 130° 4°1�5 90 140 40 70 60 90 �0 94 1�4 110 14,0 �75 4° 1�0° 3°S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Clevis bracket GA Swivel eye bracket Inthiscombinationtheclevis bracketGAortheSwiveleye bracketcanbeattachedtothe cylinder.

Deliveredasindividualmountings,notmountedtogether,andcompletewithmountingscrewsforattachmenttocylinder.

Cyl. A B C CN d3 E FL L TG1 XA* XD* Z1 Z�bore h9 H13 ±0,�mm mm mm mm mm mm mm mm mm mm mm mm

3� 10 44 41 10 6,6 45 �� 1� 3�,5 164 14� 4° 105° 40 10 50 48 1� 6,6 5� �5 15 38,0 185 160 4° 1��° 50 10 54 54 16 9,0 65 �7 17 46,5 197 170 4° 84° 63 1� 64 60 16 9,0 75 3� �0 56,5 ��� 190 4° 116° 80 16 7� 75 �0 11,0 95 36 �0 7�,0 �46 �10 4° 84°100 16 8� 85 �0 11,0 115 41 �5 89,0 �71 �30 4° 90°S=Strokelength *Doesnotapplytocylinderswithlockunit,pleaserefertopage48

Swivel rod eye Clevis bracket GA Inthiscombinationtheswivel rodeyeisattachedtothe cylinder.

SameasabovebutwithSwivel rodeye,screwsandpinin stainlesssteel.Deliveredasindividualmountings,notmountedtogether,andcompletewithmountingscrewsforattachmenttocylinder.

Cyl. A Bmin Bmax CE E ER FL k kk M l TG1 Z1 Z�mm mm mm mm mm mm mm mm mm mm mm mm

3� �0 48,0 55 43 45 14 �� 17 M10x1,�5 5,0 41 3�,5 4° �08° 40 �� 56,0 6� 50 5� 16 �5 19 M1�x1,�5 6,0 48 38,0 4° �14° 50 �8 7�,0 80 64 65 �1 �7 �� M16x1,5 8,0 54 46,5 4° �06° 63 �8 7�,0 80 64 75 �1 3� �� M16x1,5 8,0 60 56,5 4° �14° 80 33 87,0 97 77 95 �5 36 3� M�0x1,5 10,0 75 7�,0 4° 198°100 33 87,0 97 77 115 �5 41 3� M�0x1,5 10,0 85 89,0 4° �08°1�5 51 1�3,5137 110 140 35 50 41 M�7x� 13,5 110 110,0 4° �00°

3� 0,4� P1C-4KMMA 40 0,59 P1C-4LMMA 50 0,98 P1C-4MMMA 63 1,38 P1C-4NMMA 80 �,59 P1C-4PMMA100 3,64 P1C-4QMMA1�5 5,85 P1C-4RMMA

I

TG1

E

Z1

Z1

A

KERM

CEB FL

KK

Z2

XD+S

A

B

ØCN

C

3TG

E1

Ød

Z1

Z1

ALFL

XA+S

Z2

XD+S

ER

R1

CN

CH

G2G3

G1

B

I3

2

5K

K1KK

2

S

Z1

Z1

H6

E

Z2

Z3

3� 0,40 P1C-4KMQA 40 0,54 P1C-4LMQA 50 0,95 P1C-4MMQA 63 1,�5 P1C-4NMQA 80 �,44 P1C-4PMQA100 3,46 P1C-4QMQA1�5 7,15 P1C-4RMQA

3� 0,30 P1C-4KRVA 40 0,41 P1C-4LRVA 50 0,73 P1C-4MRVA 63 0,93 P1C-4NRVA 80 1,85 P1C-4PRVA 100 �,50 P1C-4QRVA 1�5 5,33 P1C-4RRVA

3� 0,30 P1C-4KRWA 40 0,41 P1C-4LRWA 50 0,73 P1C-4MRWA 63 0,93 P1C-4NRWA 80 1,85 P1C-4PRWA 100 �,50 P1C-4QRWA 1�5 5,33 P1C-4RRWA

CombinationsType Description Cyl.bore Weight Ordercode Ømm kg

Page 65: Parker P1D Series Actuators

65

P1D Mountings

08.01

www.parker.com/euro_pneumatic

Stainless steel screw set SetofstainlesssteelscrewsforfittingclevisbracketsMP�,MP2, MP4, MS1 and GA MP4andGAontothecylinder.Thescrewshave

aninternalhexagonalheadandareusedinspecialenvironments,e.g.thefoodindustry,orwherethereareextrademandsforprotectionagainstcorrosion.Material:AccordingtoDIN91�,Stainlesssteel,A�4pcsperpack.

Stainless steel screw set SetofstainlesssteelscrewsforfittingflangesMF1/MF� for MF1/MF2 ontothecylinder.Thescrewshaveaninternalhexagonal

headandareusedinspecialenvironments,e.g.thefoodindustry,orwherethereareextrademandsforprotectionagainstcorrosion.Material:AccordingtoDIN691�,Stainlesssteel,A�4pcsperpack

Sealing plugs Setofsealingplugstobefittedinunusedendcovers.TheplugscanbeusedforallP1Dcylinderstoavoidcollectingdirtandfluidsintheendcoverscrewrecesses.

Material:PolyamidPA4pcsperpack

3� 0,0� 9301054321 40 0,0� 9301054321 50 0,05 9301054322 63 0,05 9301054322 80 0,09 9301054323100 0,09 93010543231�5 0,15 9301054324

3� 0,0� 9301054331 40 0,0� 9301054331 50 0,04 9301054332 63 0,04 9301054332 80 0,07 9301054333100 0,07 93010543331�5 0,1� 9301054334

3� 0,01 9121742201 40 0,01 9121742201 50 0,0� 9121742202 63 0,0� 9121742202 80 0,0� 9121742203100 0,0� 91217422031�5 0,03 9121742204

AccessoriesType Description Cyl.bore Weight Ordercode Ømm kg

Page 66: Parker P1D Series Actuators

66

P1D Mountings

08.01

www.parker.com/euro_pneumatic

CombinationsTypeanddescription

Cylinders complete with mountings, sensors, speed regulation, fittings etc. Orderacompleteworkingunitonasingleordercodeinsteadofalotofseparatenumbers.Savetimeinallphases,suchaspurchasing,goodsreceptionandinstallation.Afactoryinstalledcompletecylindermakesyourworkmoreefficient!Configurefunctionsandequipmentintheorderkey.Seepages�8-49and78-8�.

3 and 4 position cylinders Thistypeofcylinderfunctionconsistsoftwocylindersinstalledbacktoback.Twocylinderswiththesamestrokegivea3positioncylinderwithasymmetricalcentreposition,whereasdifferentstrokesgivea4positioncylinderwherethetwocentralpositionscanbecalculatedfromthedifferentstrokelengths.

3and4positioncylinderscanbeorderedintwoways.

Factory-fitted P1D-T Tie-rodP1Dcylindersarecompletedatthefactoryandarejoinedtogetherasoneunitbyspecialtie-rods,seeposition9intheorderkey.Seepages36and80-8�.

Installation kit for all designs Thereisaninstallationkitforcylinderbores3�–100mmwhichmakesitpossibletojoinanytwoP1Dcylinderstogetheratanytime,tomakea3or4positioncylinder.

Pleaserefertocylindermountings,page59.

Cylinder A,P1D-T A,P1D-Sbore.mm mm mm

3� �47 �56 40 �77 �86 50 �93 306 63 3�3 336 80 355 373100 385 4031�5 461 –

S=Stroke

3position:A+�xS4position:A+S1+S�

Page 67: Parker P1D Series Actuators

67

P1D Sensors

08.01

www.parker.com/euro_pneumatic

New drop-in sensors Thecompletelynew”drop-in”P1Dsensorscaneasilybeinstalledfromthesideinthesensorgroove,atanypositionalongthepistonstroke.Thesensorsarecompletelyrecessedandthusmechanicallyprotected.Choosebetweenelectronicorreedsensorsandseveralcablelengthsand8mmandM1�connectors.ThesamestandardsensorsareusedforallP1Dversions,i.e.evenforP1DCleanwiththepatentappliedsystemofintegratedsensors.Pleasenotethatthesensorswith8mmandM1�connectorshouldhavecablelengths1mforP1DCleantoallowflexiblepositioningofthesensors,includinglongerstrokelengths.Thereisadoublejointedadapterforthetie-rodversion,whichofferssimpleandflexibleuseofstandardsensors.

Electronic sensors Thenewelectronicsensorsare”SolidState”,i.e.theyhavenomovingpartsatall.Theyareprovidedwithshort-circuitprotec-tionandtransientprotectionasstandard.Thebuilt-inelec-tronicsmakethesensorssuitableforapplicationswithhighonandoffswitchingfrequency,andwhereverylongservicelifeisrequired.

Technical dataDesign GMR(GiantMagneticResistance) magneto-resistivefunctionInstallation Fromside,downintothesensor groove,so-calleddrop-inOutputs PNP,normallyopen(alsoavailablein NPNdesign,normallyclosed, onrequest)Voltagerange 10-30VDC 10-18VDC,ATEXsensorRipple max10%Voltagedrop max�,5VLoadcurrent max100mAInternalconsumption max10mAActuatingdistance min9mmHysteresis max1,5mmRepeatabilityaccuracy max0,�mmOn/offswitchingfrequency max5kHzOnswitchingtime max�msOffswitchingtime max�msEncapsulation IP67(EN605�9)Temperaturerange –�5°Cto+75°C –�0°Cto+45°C,ATEXsensorIndication LED,yellowMaterialhousing PA1�Materialscrew StainlesssteelCable PVCorPUR3x0.�5mm�

seeordercoderespectively

Reed sensors Thesensorsarebasedonprovenreedswitches,whichofferreliablefunctioninmanyapplications.Simpleinstallation,aprotectedpositiononthecylinderandclearLEDindicationareimportantadvantagesofthisrangeofsensors.

Technical dataDesign ReedelementMounting Fromside,downintothesensor groove,so-calleddrop-inOutput Normallyopen,ornormallyclosedVoltagerange 10-30VAC/DCor 10-1�0VAC/DC �4-�30VAC/DCLoadcurrent max500mAfor10-30Vor max100mAfor10-1�0V max30mAfor�4-�30VBreakingpower(resistive) max6W/VAActuatingdistance min9mmHysteresis max1,5mmRepeatabilityaccuracy 0,�mmOn/offswitchingfrequency max400HzOnswitchingtime max1,5msOffswitchingtime max0,5msEncapsulation IP67(EN605�9)Temperaturerange –�5°Cto+75°CIndication LED,yellowMaterialhousing PA1�Materialscrew StainlesssteelCable PVCorPUR3x0.14mm�

seeordercoderespectively

Page 68: Parker P1D Series Actuators

68

P1D Sensors

08.01

www.parker.com/euro_pneumatic

Sensors Adapter for P1D-T

3515,7 A

B

Cyl.bore A Bmm mm mm

3� 35 �6 40 39 30 50 44 30 63 50 4� 80 54 5�100 6� 601�5 74 69

31,5

37

M8x

1M

8x1

4,3

6,1

4,6

9,7

31,5 - 36

1

4

3DC

Brown

Black

Blue

1

4

3AC/DC

1

4

3+(–)VAC/DC

Signal

–(+)VAC/DC

Brown

Black

Blue

AC/DC

Brown

Blue

P8S-GRFLX / P8S-GRFLX2

143

+(–)VAC/DC

Signal–(+)VAC/DC

M8 M12

1

4

3+VDC

Signal

–VDC143

+VDC

Signal–VDC

M8 M12

Electronic sensors Reed sensors

AC/DC

P8S-GCFPX

Brown

Blue

Dimensions

Page 69: Parker P1D Series Actuators

69

P1D Sensors

08.01

www.parker.com/euro_pneumatic

Ordering data

Output/function Cable/connector Weight Order code kg

Electronic sensors , 10-30 V DC

PNPtype,normallyopen 0,�7mPUR-cableand8mmsnap-inmaleconnector1) 0,007 P8S-GPSHXPNPtype,normallyopen 1,0mPUR-cableand8mmsnap-inmaleconnector 0,013 P8S-GPSCXPNPtype,normallyopen 1,0mPUR-cableandM8screwmaleconnector 0,013 P8S-GPCCXPNPtype,normallyopen 0,�7mPUR-cableandM1�screwmaleconnector1) 0,015 P8S-GPMHXPNPtype,normallyopen 3mPVC-cablewithoutconnector 0,030 P8S-GPFLXPNPtype,normallyopen 10mPVC-cablewithoutconnector 0,110 P8S-GPFTX

Electronic sensor 18-30 V DC ATEX-certified See ATEX information pages 22 - 25.

TypePNP,normallyopen 3mPVC-cablewithoutconnector 0,030 P8S-GPFLX/EX

Reed sensors , 10-30 V AC/DC

Normallyopen 0,�7mPUR-cableand8mmsnap-inmaleconnector1) 0,007 P8S-GSSHXNormallyopen 1,0mPUR-cableand8mmsnap-inmaleconnector 0,013 P8S-GSSCXNormallyopen 1,0mPUR-cableandM8maleconnector 0,013 P8S-GSCCXNormallyopen 0,�7mPUR-cableandM1�screwmaleconnector1) 0,015 P8S-GSMHXNormallyopen 1,0mPUR-cableandM1�screwmaleconnector 0,0�3 P8S-GSMCXNormallyopen 3mPVC-cablewithoutconnector 0,030 P8S-GSFLXNormallyopen 10mPVC-cablewithoutconnector 0,110 P8S-GSFTXNormallyclosed 5mPVC-cablewithoutconnector�) 0,050 P8S-GCFPX

Reed sensors, 10-120 V AC/DC

Normallyopen 3mPVC-cablewithoutconnector 0,030 P8S-GRFLX

Reed sensorer, 24-230 V AC/DC

Normaltöppen 3mPVC-kabelutankontakt 0,030 P8S-GRFLX2

1)NotincombinationwithP1DClean(tooshortcable)�)WithoutLED

Adapter for tie-rod design

Description Weight Order code kg

DoublejointedadapterforcylinderP1D-TcylinderboreØ3�toØ1�5mm 0,07 P8S-TMA0X

II3G EEx nA II T4X II3D 135 °C IP67

Page 70: Parker P1D Series Actuators

70

P1D Sensors

08.01

www.parker.com/euro_pneumatic

Asaccessoriesthesystemcomprisesalargenumberofdifferentcablesinordertomeetallrequirementsthatmayariseandtomaketheinstallationsimple,fastandreliable.Cableswithmoulded8mmsnap-inroundcontactsinbothends.Thecablesareavailableintwotypes,onewithastraightmaleandfemaleconnectorsrespectively,andonewithastraight3-polemaleconnectorinoneendandanangled3-polefemaleconnectorintheotherend.

Technical dataContactsMoulded8mmsnap-inmale/femalecontacts.Enclosure IP67

CableConductor 3x0,�5mm�(3�x0,10mm�)Sheath PVC/PURColour Black

Designation Weight Order code kg

Cablewithstraightcontacts,0,�m 0,0� 9121717014Cablewithstraightcontacts,0,3m 0,0� 9121717015Cablewithstraightcontacts,0,5m 0,03 9121717016Cablewithstraightcontacts,1,0m 0,03 9121717017Cablewithstraightcontacts,�,0m 0,05 9121717018Cablewithstraightcontacts,3,0m 0,07 9121717019Cablewithstraightcontacts,5,0m 0,1� 9121717020Cablewithstraightcontacts,10m 0,�3 9121717021

Designation Weight Order code kg

Cablewithstraightandangledconnectors,0,�m0,0� 9121717022Cablewithstraightandangledconnectors,0,3m0,0� 9121717023Cablewithstraightandangledconnectors,0,5m0,03 9121717024Cablewithstraightandangledconnectors,1,0m0,03 9121717025Cablewithstraightandangledconnectors,�,0m0,05 9121717026Cablewithstraightandangledconnectors,3,0m0,07 9121717027Cablewithstraightandangledconnectors,5,0m0,1� 9121717028Cablewithstraightandangledconnectors,10m 0,�3 9121717029

Type of cable Cable/connector Weight Order code kg

Cables for sensors, complete with one female connector

Cable,FlexPVC 3m,8mmSnap-inconnector 0,07 9126344341Cable,FlexPVC 10m,8mmSnap-inconnector 0,�1 9126344342Cable,SuperFlexPVC 3m,8mmSnap-inconnector 0,07 9126344343Cable,SuperFlexPVC 10m,8mmSnap-inconnector 0,�1 9126344344Cable,Polyurethane 3m,8mmSnap-inconnector 0,01 9126344345Cable,Polyurethane 10m,8mmSnap-inconnector 0,�0 9126344346Cable,Polyurethane 5m,M1�screwconnector 0,07 9126344348Cable,Polyurethane 10m,M1�screwconnector 0,�0 9126344349

Male connectors for connecting cablesCableconnectorsforproducingyourownconnectingcables.Theconnectorscanbequicklyattachedtothecablewithoutspecialtools.Onlytheoutersheathofthecableisremoved.TheconnectorsareavailableforM8andM1�screwconnectorsandmeetprotectionclassIP65.

Connector Weight Order code kg

M8screwconnector 0,017 P8CS0803JM1�screwconnector 0,0�� P8CS1204J

Connecting cables with one connectorThecableshaveanintegralsnap-infemaleconnector.

Cableswithstraight3-polemaleandfemaleconnectorsrespectively. Cableswithastraight3-polemaleconnectorinoneendandanangled3-polefemaleconnectorintheotherend.

Ready to use connecting cables with connectors at each end

Page 71: Parker P1D Series Actuators

71

08.01

www.parker.com/euro_pneumatic

Connection block Valvetronic 110TheValvetronic110isaconnectionblockthatcanbeusedforcollectingsignalsfromsensorsatvariouspointsonamachineandconnectingthemtothecontrolsystemviaamulticorecable.Valvetronic110canalsobeusedforcentralconnectionofthemulti-corecabletotheoutputsofacontrolsystem,andcanbelaidtoamachinewheretheoutputsignalscanbeconnected.Theconnectionblockhasten8mmsnap-incircularconnectorsandamulti-corecablewhichisavailableinlengthsof3or10m.Theconnectionsontheblockarenumberedfrom1to10.Blankingplugsareavailableforunusedconnections,aslabelsformarkingtheconnectionsofeachblock.

18,7

12,5

825 12

9,2 20,5

L

30,5

8575

M3

6 7 8 9 10

1 2 3 4 5

3 3 3 3 3

2 2 2 2 2

1 1 1 1 1

3 3 3 3 3

2 2 2 2 2

1 1 1 1 1

A

5 43 21

67 89 10B

P1D Connectionblock

Technical dataConnections:Ten3-polenumbered8mmroundsnap-infemalecontacts Inputblock Pin1 Common,+�4VDC Pin� Inputsignal Pin3 Common,0V

Outputblock Pin1 Common,GND Pin� Outputsignal Pin3 Common,0V

Electrical data:Voltage �4VDC(max.60VAC/75VDC)Insulationgroup accordingtoDIN0110classCLoad max.1Aperconnection totalmax.3A

Cable:Length 3mor10mTypeofcable LifYY11YConductor 1�Area 0.34mm�

Colourmarking AccordingtoDIN47100

32

1

32

1

Mechanical dataEnclosure IP67,DIN40050withfittedcontactsand/or blankingplugs.Temperature –�0°Cto+70°C

MaterialBody PA6,6VDaccordingtoUL94Contactholder PBTPSnap-inring LDPEMouldingmass EpoxySeal NBRScrews Platedsteel

Industrial durabilityGoodchemicalandoilresistance.Testsshouldbeperformedinaggressiveenvironments.

Ordering data

Designation Weight Order code kg

ConnectionblockValvetronic110with3mcable 0,3� 9121719001 ConnectionblockValvetronic110with10mcable 0,95 9121719002

Blankingplugs(packof10) 0,0� 9121719003 Useblankingplugstocloseunusedconnections.

Labels(packof10) 0,0� 9121719004 Whitelabelstoinsertingroovesonthesideoftheconnection

Dimensions and wiring diagrams

Conductor Colour Input Output

1 Pink Signal 1 Signal 1 2 Grey Signal 2 Signal 2 3 Yellow Signal 3 Signal 3 4 Green Signal 4 Signal 4 5 White Signal 5 Signal 5 6 Red Signal 6 Signal 6 7 Black Signal 7 Signal 7 8 Violet Signal 8 Signal 8 9 Grey-Pink Signal 9 Signal 9 10 Red-Blue Signal 10 Signal 10 A Blue 0 V 0 V B Brown +24 V PE

Page 72: Parker P1D Series Actuators

7�

P1D Sensors

08.01

www.parker.com/euro_pneumatic

Pneumatic cylinder sensor for P1D-TAnidealsolutionwhereadirectpneumaticsignaliswantedfromacylindersensortoapneumaticcontrolsystem,forexample.Thiscouldbeamachineordeviceinwhichonlycompressedairisavailable,andanelectricitysupplytonormalcylindersensorswouldinvolveseriousproblemsorconsider-ableexpense.

Function:Non-contactingsensingofapneumaticcylinder,triggeringanoutputsignal(conn.�)fromtheintegrated3/�NCvalve,whichisactivatedbyamagneticfieldorironcoreandhasareturnspring.

Ifmorethanonesensorisusedwithacylindertheremustbeadistanceofatleast�0mmbetweensensorstopreventtheminfluencingeachother.

Toavoidinterference,theremustbeaminimumspacingof15mmtosteeldetails.

Theoutlet(conn.3)mustnotbeblockedorrestrictedasthiscanimpairthefunctionofthesensor.

Thesensorisfastenedtothecylinderusingthespecialsensorfixing.

Technical data:Workingpressure: min�tomax6barTemperature: -15to+60°CAirquality: 3.4.3toISO8573-1(mustbeoilfree)Function: 3/�NCvalveFlow: 40NlperminuteConnection: forplasticpipewith�,5-3mminternaldiameterActivationdistance: formagnet:min9mmActivationdistance: forFe:approx.�mmRepetitionaccuracy: +/-0.�mmCylindervelocity: max1m/s(dependsonmagneticfield, interferencefromsteelinenvironment, signallengthrequirementfromcontrol system….)Distancebetweensensors:min�0mmDistancefromsensortosteeldetails: min15mmFixing: withsensorfixingorwithanM4threadincaseSensing: non-contacting(alsothroughawallofnon-magneticmaterial)

Order codes

Name Weight Order code kg

Pneumaticsensor 0,0� P8S-A34XCylinderfixing 0,01 P8S-AMA1

13

2

Cylinder fixing

Page 73: Parker P1D Series Actuators

73

P1D Sensors

08.01

www.parker.com/euro_pneumatic

40,3

34

15 15

17

M4

29,3

2

3,5

1,2

14,5

1,6

16,7

18

4

812

1,3

3,9

9,1

14,3

18,2

Dimensions

Active surface for sensing iron core

Indication

Page 74: Parker P1D Series Actuators

74

08.01

www.parker.com/euro_pneumatic

P1D Sealkits

Grease for P1D

Standard 30g 9127394541

Hightemperature 30g 9127394521

Lowtemperature 30g 9127394541

Order codes

Cyl.bore P1D cylinder version mm Standard HighTemp LowTemp Hydraulic P1D-S,P1D-T,P1D-C,P1D-F P1D-S P1D-S P1D-S

3� P1D-6KRN P1D-6KRF P1D-6KRL P1D-6KRH 40 P1D-6LRN P1D-6LRF P1D-6LRL P1D-6LRH 50 P1D-6MRN P1D-6MRF P1D-6MRL P1D-6MRH 63 P1D-6NRN P1D-6NRF P1D-6NRL P1D-6NRH 80 P1D-6PRN P1D-6PRF P1D-6PRL P1D-6PRH 100 P1D-6QRN P1D-6QRF P1D-6QRL P1D-6QRH 1�5 P1D-6RRN P1D-6RRF P1D-6RRL P1D-6RRH

Cyl.bore P1D optional cylinder versions Throughrod mm Standardtemperature P1D-S,P1D-T,P1D-C,P1D-F

3� P1D-6KRNF 40 P1D-6LRNF 50 P1D-6MRNF 63 P1D-6NRNF 80 P1D-6PRNF 100 P1D-6QRNF 1�5 P1D-6RRNF

P1D Seal kitsCompletesealkitsconsistingof:PistonsealsCushioningsealsPistonrodbearingCombinedpistonrodsealandscraperringO-rings

Materialspecification,seepage19

Cyl.bore P1D cylinder version

mm Standard temperature Standard temperature Standard temperature Standard temperature

with FPM scraper ring Dry piston rod with metal scraper ring with piston rod locking

with HDPE scraper ring

P1D-S,P1D-T, P1D-S,P1D-T, P1D-S,P1D-T, P1D-L,P1D-D,

P1D-C,P1D-F P1D-C,P1D-F P1D-C,P1D-F P1D-4

3� P1D-6KRV P1D-6KRD P1D-6KRQ P1D-6KRNL 40 P1D-6LRV P1D-6LRD P1D-6LRQ P1D-6LRNL 50 P1D-6MRV P1D-6MRD P1D-6MRQ P1D-6MRNL 63 P1D-6NRV P1D-6NRD P1D-6NRQ P1D-6NRNL 80 P1D-6PRV P1D-6PRD P1D-6PRQ P1D-6PRNL 100 P1D-6QRV P1D-6QRD P1D-6QRQ P1D-6QRNL 1�5 P1D-6RRV P1D-6RRD P1D-6RRQ P1D-6RRNL

Forotherdesignvariantswiththroughrods,orderdoublesealkitsasabove.Example:ForaP1D-SØ63withthroughrod,hightempera-tureversion,order�xP1D-6NRF

Page 75: Parker P1D Series Actuators

75

08.01

www.parker.com/euro_pneumatic

P1D Sealkits

Cyl.-dia Plastic Alu. piston piston T1 T1 NV T2 NV T3 NV NVmm Nm Nm mm Nm mm Nm mm mm

3� 4,5 15 6 8 6 6 6 40 11 30 8 8 6 6 6 50 �0 40 10 �0 8 11 8 63 �0 40 10 �0 8 11 8 80 40 1�0 14 �0 6 �0 3x16100 1�0 1�0 14 �0 6 �0 3x161�5 1�0 1�0 14 70 8 40 4x18

T1

T2

T3

T2

Seal kit= Includedinsealkit = Tighteningtorque

= Screwdriverhead = Lubricatedwithgrease,seepage74.

= Insexgrepp = Lockingfluid

Loctite 270 or Loctite 2701 locking fluid must be used

T1

Loctite 270 or Loctite 2701 locking fluid must be used

T3

T3

T3

T2

T2Variants for: low tempera-ture, high temperature, low pressure hydraulics

P1D-C

P1D otherP1D-StandardP1D-CleanP1D-Flexible PortingP1D-Tie Rod

P1D-Flexible Porting

Page 76: Parker P1D Series Actuators

76

08.01

www.parker.com/euro_pneumatic

P1D SpareParts

8 Spare parts

Cylinder dia. mm

032

040

050

063

080

100

125

Stroke** (mm) e.g. 0100 = 100 mm

Anystrokeuptomax.�800mm.

**Whenorderingpistonrodsforcylinderswithextendedpistonrod,addtogetherthestrokeandtheextensionintheorderkey.Forexample,acylinderwithstroke100mmandapistonrodextensionof�5mmisorderedwith01�5intheordernumber.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – 8 0 3 2 D G – 0 1 0 0

Piston rod

D Double-acting

F Pistonrodlocking,only chromium-platedrod

G Internalthread

H Throughrod

L Throughrod+pistonrod locking

Cylinder barrel*

A Profilecylinder

B Cylindrical(fortierod)

Tie rods

T Tierods (order4foracylinder)

*CylinderbarrelforP1DCleanandP1DFlexportcannotbeorderedwiththisorderkey.Con-tactcustomerservice

Piston rod

G Stainlesssteel

H Hard-chromiumplated

J Acid-resistantsteel

K Chromiumplatedstainless

Cylinder barrel*

A Aluminium

Tie rods

V Stainlesssteel (order4foracylinder)

Order key, spare parts

Piston rod

Cylinder barrel type A

Piston rod

Cylinder barrel type B

Tie rods

P1D with profile cylinder P1D with tie rods

Page 77: Parker P1D Series Actuators

77

08.01

www.parker.com/euro_pneumatic

Complete working units – ready for installation

PistonrodmountingsCylindermountingsFactory-fittedsensorsPistonrodthreadaccordingtoISOSpeedcontrolsorfittings

16 17 18 19 20

P 1 D – C 0 4 0 M S B 0 1 2 5 A L C N 6

Piston rod mountingsOrderP1Dwithswiveleyebracketorclevisbracketofzinc-platedorstainlesssteel–orpossiblyaFlexoCoupling.OtherexamplesfromthewiderangeareaswiveleyebracketcombinedwithclevisbracketGAandrodguid-ancemodules(plainorball-bearingtype).

Fittings or speed controlThecylindersareavailablewithfactory-fittedelboworstraightpush-infittingsfromthePrestolokrange(nickel-platedbrass).BanjospeedcontrolvalvesfromtheParkerPTFrangeareavailableasanalternative.

Factory-fitted sensorsP1DCleancanbeorderedwithfactory-fittedsensors.Thisisoftenanadvantageforothercylinderversionsaswell.Thesecylinderscomewiththesensorsmountedintheendpositions.Ifneeded,thesensorsareeasytoadjustwheninstallingthecylinders.Choosefromawiderangeofsensors–electronicorreedtype,3or10metresofcable,8mmorM1�connectors.

Cylinder mountingsAmountingisalmostalwaysneededwheninstallingacylinder.Takeadvantageoftheoppor-tunitytohavefactory-fittedmountingssuchasfootbracket,flange,clevisbracketMP�/MP4,clevisbracketGA,swiveleyebracketorcombinationsofthese.Sealingplugscanbefittedatthefactoryinunusedendcoverholes.

Save time and costsNowyoucansavetimeandmoneywhenchoosing,ordering,receivingandinstalling,byorderingacompletecylinderratherthanhavingtoorderuptotenseparateitems.

Everything under one part numberTheP1Drangemeansmorethanmajortechnicaladvances:wehavemadeitincrediblysimpletoorderP1Dcylindersascompletelyequippedworkingunitswithallaccessoriesfitted,readytoplugin.Everythingunderonepartnumber,whichyoucreatewiththehelpoftheordercodekey.

The right qualityThenewsystemsavesalotoftimeateverystage,fromorderingtocommissioning.Youcanalsobesureofgettingexactlythesameconfigurationeverytime.Allaccessoriesareguaranteedcorrectlyfitted,withthecorrecttighteningtorque.OtherexamplesfromthewiderangeareaswiveleyebracketcombinedwithclevisbracketGAandguidancemodules(plainorball-bearingtype).

P1D Ordercodekey

Page 78: Parker P1D Series Actuators

78

08.01

www.parker.com/euro_pneumatic

There is a P1D cylinder for every application P1D Standard ThebasicplatformintheP1Dfamilyoffershighperformance,thankstoitsverydurableanduser-friendlydesign.

P1D Clean with integrated sensorsTheobviouschoiceforstringenthygienerequirements,speciallydesignedfordemandingapplicationsTheperfectfitforthefoodprocessingindustry.Built-insensorsareselectedinposition18.

P1D Clean without sensor function Thecleancylinderforapplicationswhichdonotrequiresensors.ThisistheonlyP1DCleancylinderwhichisorderedwitha15-digitordercode.

Flexible Porting TheP1DFlexiblePortingcylinderisavailablewithbothconnectionsinoneendoftheendcovers.Thiscylinderalwayshasa�0-digitordercode,wherethepositionofthecylinderportsisdefinedinposition11andthetypeoffittingandtubedimensionischoseninposition�0.

P1D Ordercodekey

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – F 0 5 0 M S B 0 3 2 0 N N N N 0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – C 0 5 0 M S – 0 2 5 0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – C 0 5 0 M S – 0 3 2 0 N N C N N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 3 2 M S – 0 1 0 0

Page 79: Parker P1D Series Actuators

79

08.01

www.parker.com/euro_pneumatic

P1D Clean with Flexible Porting CombineP1DCleanwithhavingbothconnectionsinoneend,byusingtheFlexiblePortingoption.

P1D Tie-Rod ThesamebasichightechnologydesignasallotherP1Dcylinderversions,butwithatie-roddesign.FollowsthesameordercodeprinciplesasourpreviousP1Erange.

P1D complete working unitP1DStandardcanbeorderedwithafactory-fittedvalveandhosing.ThevalveseriesistherobustandcompactVikingseries,withproductcodeP�L-A(forcylinderbores3�-63),P�L-B(forcylinderbores80-100)andP�L-D(forcylinderbore1�5).

P1D cylinder with piston rod lockingTheP1Dcylinderisavailableinaversionwithpistonrodlocking,allowingthepistonrodtobelockedinanyposition.Thelockunit,oftheair/springactuatedtype,isintegratedinthefrontendpieceofthecylinder.

P1D Standard with piston rod locking

P1D Clean with piston rod locking

P1D Ordercodekey

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – T 0 5 0 M S – 0 1 2 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – C 0 5 0 M S B 0 3 2 0 N N C N 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P 1 D – V 0 5 0 M S 1 0 3 2 0 N N N N H

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – L 0 5 0 M C – 0 2 5 0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – D 0 5 0 M C – 0 2 5 0

Page 80: Parker P1D Series Actuators

80

08.01

www.parker.com/euro_pneumatic

P1D Ordercodekey

Cylinder version

S Standard

C Clean�)

F FlexiblePorting

T Tie-Rod

V Standardwithfactoryfittedvalve

L Standardwithlockunit19)

D Cleanwithlockunit19)

4 Standardwithlockunitand factoryfittedvalve19)

Stai

nles

sst

eel

Chr

omiu

m-p

late

dst

eel

Aci

d-pr

oofs

teel

Chr

om.-p

l.st

ainl

ess

stee

l

Piston rod Seals material

S C M R Standard-�0°Cto+80°C.

F G N D Hightemperatureversion6) -10°Cto+150°C. Nomagneticfunction

L K P E Lowtemperatureversion6) -40°Cto+40°C.

– J – Z Lowpressurehydraulic6)�4).

15-digit order code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

P 1 D – S 0 4 0 M S – 0 3 2 06-7-8 7-86 Rod extension only

Cylinder bore mm

032

040

050

063

080

100

125

Cylinder bore mm

K 3�

L 40

M 50

N 63

P 80

Q 100

R 1�5

Piston rod extension

E.g.KR5=Cylinderbore3�mmwithpistonrodextension=�55mm

01-99 1-99 N0-N9 ��0-��9

A0-A9 100-109 P0-P9 �30-�39

B0-B9 110-119 Q0-Q9 �40-�49

C0-C9 1�0-1�9 R0-R9 �50-�59

D0-D9 130-139 S0-S9 �60-�69

E0-E9 140-149 T0-T9 �70-�79

F0-F9 150-159 U0-U9 �80-�89

G0-G9 160-169 V0-V9 �90-�99

H0-H9 170-179 W0-W9 300-309

J0-J9 180-189 X0-X9 310-319

K0-K9 190-199 Y0-Y9 3�0-3�9

L0-L9 �00-�09 Z0-Z9 330-339

M0-M9 �10-�19

5

Bot

hfro

nt

Bot

hre

ar

Cylinder ports Flexible porting

Port location

H3) J3) Gthreads,BSPP(Ø80-1�5)

B4) C4) Push-in,metric(Ø3�-80)

Cylinder ports Other

Gthreads,BSPPrearandfront

Factory fitted valve type

0 airactuated

1 Electricallyactuated �4VUC,LED+VDR (AC/DCUniversalCurrent) Completewithrectifier

4 Electricallyactuated �4VUC,LED+VDRmed with5mintegralcable (AC/DCUniversalCurrent) Completewithrectifier

7 Electricallyactuated �4VUC,LED+VDRmed with10mintegralcable (AC/DCUniversalCurrent) Completewithrectifier

2 115V/50Hz,1�0V/60Hz, LED+VDR

3 �30V/50Hz,�40V/60Hz, LED+VDR

11

9

16

10

12-13-14-15

Stroke length see next page

No

plug

s

With

plu

gs8)

Factory-fitted piston rod mountings and sealing plugs

S A Swivelrodeye,zinc-platedsteel

T 1 Swivelrodeye,stainlesssteel

V E Swivelrodeye,zinc-platedsteel andclevisbracketGA

W 2 Swivelrodeye,stainlesssteel andclevisbracketGA

C B Clevis,zinc-platedsteel

D 3 Clevis,stainlesssteel

F G Flexocoupling,zinc-platedsteel

X P Oneadditionalpistonrodnut9)

Y 4 Pistonrodnutinstainlesssteel10)

Z 5 Pistonrodnutinacid-proofsteel

6 7 Withoutpistonrodnut

H L Rodguidance,H,ballbearings18)

J M Rodguidance,H,plainbearings18)

K Q Rodguidance,U,plainbearings18)

N R None

II 2GD c T4 120 °CValidforP1D-S***MS-****,seeATEXinformationpages��-�5.

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

Std

scra

per

Met

alav

skra

pare

�5)

HD

PEs

crap

er�3

)

FPM

ssc

rape

r�6)

End cover screws Function Standard Stainless steel22)

M Q D V A S H W Double-acting

F R E B G T Y Z Double-acting throughrod

2 4 6 8 – – – – 3and4positioncylinders

C J K L – – – – Tandem

Page 81: Parker P1D Series Actuators

81

08.01

www.parker.com/euro_pneumatic

P1D Ordercodekey

Stroke (mm) e.g. 0100 = 100 mm

Thelongeststrokeina4positioncylinder.(Totalstrokelengthuptomax�800mm,seeorderingexampleonpage36)

Fron

tend

orl

eft11

)

Rea

rend

orr

ight

11)

Fron

tand

rear

end

Factory-fitted sensors

Cable exit

F R – �sensors�4VDCpnp,3mcable

G H – �sensors�4VDCpnp,10mcable

C S – �sensors�4VDCpnp,8mmconnector,1mcable�1)

K L – �sensorsReedtype,3mcable

T V – �sensorsReedtype,10mcable

M Q – �sensorsReedtype,8mmconnector,1mcable�1)

– – 3 3sensors�4VDCpnp,8mmconnector,1mcable�1)

– – Z 3sensorsReedtype,8mmconnector,1mcable�1)

– – 4 4sensors�4VDCpnp,8mmconnector,1mcable�1)

– – W 4sensorsReedtype,8mmconnector,1mcable�1)

612) 713) 814) Nofactory-fittedsensorsP1DClean

N NosensorsP1D(excl.P1DClean)

Speed controls or Valve function fittings for tube dimension

Speed controls17), Air actuated Series PTF4PB16)

X inbothendsfortube4mm15) A Air-Air,5/�

Y inbothendsfortube6mm15) B Air-Spring,5/�

Z inbothendsfortube8mm15) C Air-Air,5/3,closedcentreposition

P inbothendsfortube10mm15) D Air-Air,5/3,ventedcentre

R inbothendsfortube1�mm15) E Air-Air,5/3,pressurisedcentre

Push-in fitting, elbow type for: Electrically actuated internal supply

4 Tubedimension4mm15) F Elec-Elec,5/�

6 Tubedimension6mm15) H Elec-Spring,5/�

8 Tubedimension8mm15) K Spring-Elec,5/��0)

0 Tubedimension10mm15) M Elec-Elec,5/3,closedcentreposition

2 Tubedimension1�mm15) Q Elec-Elec,5/3,ventedcentre

Push-in fitting, straight type for: S Elec-Elec,5/3,pressurisedcentre

1 Tubedimension4mm15) Electrically actuated external supply

3 Tubedimension6mm15) G Elec-Elec,5/�

5 Tubedimension8mm15) J Elec-Spring,5/�

7 Tubedimension10mm15) L Spring-Elec,5/��0)

9 Tubedimension1�mm15)

N None

Stroke (mm) e.g. 0100 = 100 mm

Optionalstrokelengthsupto�800mm.Standardstrokesseetablepage18

17

18

20

12-13-14-15

17-18-19-20

1-26) Information notes see page 82

4-position cylinders only

Piston rod thread

N AccordingtoISO-standard1)

6 Internalpistonrodthread

19

Cylinder mountings

90° 0° 90°=shaftsquareto,0°=shaftinlinewithports5)

1 3 FlangeMF1/MF�infrontend

B 4 FlangeMF1/MF�inrearend

2 K FlangeMF1/MF�inbothends

F – FootbracketsMS1(bothends)

C U ClevisbracketGA

E V ClevisbracketMP4

S W Swiveleyebracket

T Y ClevisbracketMP�

L Z ClevisbracketMP�+MP4

X 5 ClevisbracketMP�+pivotbracketwithrigidbearing

Q 0 ClevisbracketGA+pivotbracketwithswivelbearing

M A ClevisbracketGA+swiveleyebracket

D 6 CentretrunnionMT4,midposition6)

G 7 TrunnionMT4,optionalpos.(XV-meas.pos18-�0)7)

H P Trunnionflangeinfrontend

J 8 Trunnionflangeinrearend

N None

20-digit order code 16 17 18 19 20

S N N N N1)

Page 82: Parker P1D Series Actuators

8�

08.01

www.parker.com/euro_pneumatic

Information notes1) CodeNforpistonrodthreadaccordingtotheISO-

standard.Otherthreadsonrequest.

�) P1DCleanwithoutsensorfunction,seepage41.

3) OnlyforP1D-Fbore80-1�5mm.Selectoptionalfittingsinposition�0,seepage4�.

4) OnlyforP1D-F(FlexiblePorting)bore3�-63mm.Selectfittingsinposition�0,seepage4�.

5) Shaftorpivotssquaretoorinlinewiththecylinderports.

6) ForversionsP1D-SandP1D-T.

7) OnlyforP1D-TandP1D-S,XV-measure(fromthepistonrodthreadaccordingtoISOtothecentreofthepivots)statedinmminpositions18-�0(max999).

8) Validonlyforcylinderswithfactory-fittedcylindermount-ings.P1DCleancylindersarealwaysdeliveredwith4sealingplugs.

9) P1Dcylindersarealwaysdeliveredwithonepistonrodnutinzinc-platedsteel,exceptP1DCleanwhichisdeliveredwiththepistonrodnutinstainlesssteel.CodesXandPmeanthatthecylinderisdeliveredwithoneadditionalnutofthesametype.

10)Thepistonrodnutinzinc-platedsteelisreplacedbyanutinstainlesssteel(P1DCleanisalwaysdeliveredwithonepistonrodnutinstainlesssteel).

11)LeftandrightvalidforP1DStandardandP1DTie-Rodseenfrombehindwiththeportsontop.ThesensorscanonlybemountedontheleftforP1DFlexiblePorting.

1�)Nofactory-fittedsensors,butpreparedforcableexitinthefrontend(max.�sensors).

13)Nofactory-fittedsensors,butpreparedforcableexitintherearend(max.�sensors).

14)Nofactory-fittedsensors,butpreparedforcableexitinbothends(max.4sensors).

15)Tochoosespeedcontrolandfittings,pleaserefertopage33forP1DStandardandpage4�forP1DFlexiblePorting.

16)P1DCleancylindershavefactoryinstallednickelplatedversionsofthePTFseries.

17)NotavailablewithP1DFlexiblePortingbore3�-63mm.

18)Validforbore3�-100mm.

19)OnlyforpistonrodmaterialtypeCandR.

P1D Ordercodekey

�0)Pistoninextendedpositionwithunactuatedvalve.

�1)Thestandardcablelengthis0.�77m.However,P1DCleanissuppliedwith1mcablelength.

��)Ifstainlesssteelendcoverscrewsareselected,thepistonrodnutsarealsosuppliedinstainlesssteel.

�3)Foroperationwithdrypistonrod.IntendedforvariantsP1D-S,P1D-C,P1D-F,P1D-TandP1D-V

�4)Thesealsystemforlowpressurehydraulicsdemandsahardchromedsurfaceforproperfunction.

�5) Themetalscraperringrequiresahard-chromiumplatedpistonrod.IntendedforvariantsP1D-S,P1D-TandP1D-V.

�6)FPMscrapershouldbechosenforhigherchemicalresist-anceonstandardtemperatureversionsonly.

Page 83: Parker P1D Series Actuators
Page 84: Parker P1D Series Actuators

AE – UAE, Dubai Tel: +971 4 8875600 [email protected]

AR – Argentina, Buenos Aires Tel: +54 3327 44 4129

AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 [email protected]

AT – Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 970 [email protected]

AU – Australia, Castle Hill Tel: +61 (0)2-9634 7777

AZ – Azerbaijan, Baku Tel: +994 50 2233 458 [email protected]

BE/LX – Belgium, Nivelles Tel: +32 (0)67 280 900 [email protected]

BR – Brazil, Cachoeirinha RS Tel: +55 51 3470 9144

BY – Belarus, Minsk Tel: +375 17 209 9399 [email protected]

CA – Canada, Milton, Ontario Tel: +1 905 693 3000

CH – Switzerland, Etoy Tel: +41 (0) 21 821 02 30 [email protected]

CN – China, Shanghai Tel: +86 21 5031 2525

CZ – Czech Republic, Klecany Tel: +420 284 083 111 [email protected]

DE – Germany, Kaarst Tel: +49 (0)2131 4016 0 [email protected]

DK – Denmark, Ballerup Tel: +45 43 56 04 00 [email protected]

ES – Spain, Madrid Tel: +34 902 33 00 01 [email protected]

FI – Finland, Vantaa Tel: +358 (0)20 753 2500 [email protected]

FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25 [email protected]

GR – Greece, Athens Tel: +30 210 933 6450 [email protected]

HK – Hong Kong Tel: +852 2428 8008

HU – Hungary, Budapest Tel: +36 1 220 4155 [email protected]

IE – Ireland, Dublin Tel: +353 (0)1 466 6370 [email protected]

IN – India, Mumbai Tel: +91 22 6513 7081-85

IT – Italy, Corsico (MI) Tel: +39 02 45 19 21 [email protected]

JP – Japan, Fujisawa Tel: +(81) 4 6635 3050

KR – South Korea, Seoul Tel: +82 2 559 0400

KZ – Kazakhstan, Almaty Tel: +7 7272 505 800 [email protected]

LV – Latvia, Riga Tel: +371 6 745 2601 [email protected]

MX – Mexico, Apodaca Tel: +52 81 8156 6000

MY – Malaysia, Subang Jaya Tel: +60 3 5638 1476

NL – The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 [email protected]

NO – Norway, Ski Tel: +47 64 91 10 00 [email protected]

NZ – New Zealand, Mt Wellington Tel: +64 9 574 1744

PL – Poland, Warsaw Tel: +48 (0)22 573 24 00 [email protected]

PT – Portugal, Leca da Palmeira Tel: +351 22 999 7360 [email protected]

RO – Romania, Bucharest Tel: +40 21 252 1382 [email protected]

RU – Russia, Moscow Tel: +7 495 645-2156 [email protected]

SE – Sweden, Spånga Tel: +46 (0)8 59 79 50 00 [email protected]

SG – Singapore Tel: +65 6887 6300

SK – Slovakia, Banská Bystrica Tel: +421 484 162 252 [email protected]

SL – Slovenia, Novo Mesto Tel: +386 7 337 6650 [email protected]

TH – Thailand, Bangkok Tel: +662 717 8140

TR – Turkey, Istanbul Tel: +90 216 4997081 [email protected]

TW – Taiwan, Taipei Tel: +886 2 2298 8987

UA – Ukraine, Kiev Tel +380 44 494 2731 [email protected]

UK – United Kingdom, Warwick Tel: +44 (0)1926 317 878 [email protected]

US – USA, Cleveland Tel: +1 216 896 3000

VE – Venezuela, Caracas Tel: +58 212 238 5422

ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700 [email protected]

Catalogue PDE2570TCUK-ul. October 2008

Your local authorized Parker distributor

© 2008 Parker Hannifin Corporation. All rights reserved.

Parker Worldwide

European Product Information Centre

Free phone: 00 800 27 27 5374

(from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE,

IT, PT, SE, SK, UK)

Parker Hannifin LtdPneumatic Division EuropeThe Collins Centre,Lichfield South, Wall Island,Birmingham Road, Lichfield.WS14 0QP United KingdomTel.: +44 (0) 1543 483800Fax: +44 (0) 1543 483801www.parker.com/euro_pneumatic