partnering with potws to use p2 to achieve industrial phosphorus reduction cindy mccomas university...
TRANSCRIPT
Partnering with POTWs to Use P2 to Achieve Industrial Phosphorus Reduction
Cindy McComas
University of Minnesota—MnTAP
612-624-4678
Point vs Non Point Phosphorus Sources--Minnesota River Basin
High flow
Non point 90 %
Point source 10 %
Low flow
36 %
64 %
Challenges Facing WWTFs
• Reduce phosphorus and other pollutant loading
• Prepare Phosphorus Management Plans
• Meet 1 mg/L limit
• Aging systems
Three Strategies for Phosphorus Reduction
• Industrial/commercial/institutional
• Residential education
• Removal at POTW
Industrial Assistance Approach
• Contact with POTWs in three basins: Upper and Lower Mississippi Rivers, Minnesota River
• Identify industrial phosphorus contributors
• Provide phosphorus reduction assistance to industrial contributors (site visits, interns, teams)
MnTAP, University of Minnesota
• Site visits
• Student interns
• Facilitated industry teams
• Resources for mercury elimination
Industrial Sources of Phosphorus
• Metal conversion coatings (prior to painting)
• Food processing and food waste
• Cleaning and sanitizing operations
Electrolux, St. Cloud
• Manufactures freezers
• Switched two cleaning/conversion coating lines to no phosphorus
• Reduced phosphorus by 90% from 42 lb/day to below 5 lb/day
Bongards Creameries, Norwood
• Butter, cheese and whey powder
• Changes: – clean in place systems
– dry cleanup prior to wet cleanup
– installed level sensors on tanks
• Reduced phosphorus by 60% from 150 lb/day to 60 lb/day
Schwan Food Company, Marshall
• Frozen foods• Switched to low/
no P cleaners and sanitizers
• Reduced P from 36 lb/day to 13 lb/day; 8,400 lb/yr
• 30% reduction at the same time as a 31% increase in flow
Industrial Loading Impact on POTW
• City of Richmond and meat locker• Wastewater treatment plant went
from influent of 11.25 ppm (9.4 lb/day) to 5 ppm (4.2 lb/day)
• Meat locker reduced 1,092 lb phosphorus/yr by keeping material off the floor and moving to no-phosphorus cleaners
Activity Results
• Contacts: 200 POTWs 131 industrial
facilities
• Site visits: 62 POTWs113 industries
• Intern projects: 7
Outcome Results
• Reduced– Phosphorus 65,950 lb
– BOD/TSS 7.5 million lb
– Water 104 million gal
• Cost savings to businesses– $3.2 million
Lessons Learned
• Partnering with POTWs to reach industries
• P2 is an effective tool to reduce P and other pollutants to POTWs
• Regulatory requirements are motivators (PMP and P limits)
• Industries save money due to more efficient use of raw materials
• POTWs cut costs for chemical use
Next Steps—Community Wide Reduction Effort
• Partner with cities
• Inventory businesses
• Educate business and residential contributors
• Provide assistance to identify phosphorus reduction options
• Measure reductions