patient care devices himss ihe showcase ’09 review & ‘10 planning
TRANSCRIPT
![Page 1: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/1.jpg)
Patient Care DevicesPatient Care Devices
HIMSS IHE ShowcaseHIMSS IHE Showcase’’09 Review & ‘10 Planning09 Review & ‘10 Planning
![Page 2: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/2.jpg)
2
General ’09 Feedback
General observations from ‘09…General observations from ‘09… Great exposure & interest!
PCD Message repeated too often / took too long to communicate
Too little vendor system exposure (vs. too much in the past)
PCD still an Interoperability Island
Live vs. Staged? (e.g., heart alarm) – Show live as much as possible!
![Page 3: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/3.jpg)
3
General ’09 Feedback
General observations from ‘09…General observations from ‘09… Engagement of tour participants to
pursue / promote PCD solutions.
More clearly address “where do I buy this?” (user’s guide? Theater? Certification/Connectathon testing?)
Desire for “private” vendor tours – guidelines? Limitations?
Utilize “distributed demo” opportunity? Showcase screen for remote data sources?
![Page 4: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/4.jpg)
4
General ’09 Feedback
General observations from ‘09…General observations from ‘09… Pre-conference vendor-specific video
that could be presented in vendor’s area
Off-hours vendor-specific tours?
Paul’s Shot-Pump Profile!
…
![Page 5: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/5.jpg)
5
Welch AllynWelch AllynConnexConnexTMTM
DataDataManagementManagement
SystemSystem
Vital Signs Monitor
GEGE
AwareAwareGatewayGateway
Patient Monitor, Ventilator
PhilipsPhilips
IntellivueIntellivueInformationInformation
CenterCenter
Patient Monitor, Ventilator
Emergency Care Intensive Care
LiveDataLiveData
OR-DashBoardOR-DashBoard
GE GE
CentricityCentricity®®
PeriopPeriopAnesthesiaAnesthesia
DraegerDraeger
InnovianInnovian®®
Solution SuiteSolution Suite
Patient Monitor, Anesthesia Sys
B. BraunB. BraunDoseTracDoseTracTMTM
InfusionInfusionManagementManagement
SoftwareSoftware
InfusionDevices
Perioperative Care
PhilipsPhilips
Intellivue ClinicalIntellivue ClinicalInformationInformation
PortfolioPortfolio
PCD @ HIMSS ’07 Systems
![Page 6: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/6.jpg)
6
PCD @ HIMSS ’08 Systems
![Page 7: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/7.jpg)
7
GE GE CentricityCentricity®®
Periop Anes.Periop Anes.
Enterprise
DOC
DOC
Patient Patient
LiveDataLiveDataOR –OR –
DashBoardDashBoardTMTM
DOR = Device Observation Reporter IOP = Infusion Order Programmer
DOC = Device Observation Consumer IOC = Infusion Order Consumer
AR = Alarm Reporter / AM = Alarm Manager
PDQ/PAMServer
PhilipsPhilipsIntelliVueIntelliVue ClinicalClinical
Info PortfolioInfo Portfolio
DOC DOC
DraegerDraegerInnovianInnovian® ® WebWeb
CapsuleCapsule
GE GE CentricityCentricity®®
EnterpriseEnterprise
DOC
LiveData LiveData Alert ManagerAlert Manager
PhilipsPhilipsEmerginEmergin
AM
OR
TimeServer
Step-DownICU
AM
Hospital Bed,BIS Monitor
CapsuleCapsuleDataCaptorDataCaptor
DOR,AR
Patient Monitor
DOR,AR
PhilipsPhilipsIntelliVueIntelliVue
Info. CenterInfo. Center
AR DOR,AR
CernerCerner
CareMobileCareMobileTMTM
DOCIOP
AC
DOR,AR
Hospital Bed,VS Monitor
CernerCerner
CareAwareCareAwareTMTM
DOR,AR
InfusionDevices
IOC
B.
Bra
un
B.
Bra
un
Ho
sp
ira
Ho
sp
ira
Ca
rdin
al
Ca
rdin
al
Patient Monitor,Ventilator
DOR
GEGEAwareAware
GatewayGateway
DOR,AR
InfusionDevices
IOC
B.
Bra
un
B.
Bra
un
Ho
sp
ira
Ho
sp
ira
Ca
rdin
al
Ca
rdin
al
Patient Monitor,Anesthesia Sys
DOR, AR
DraegerDraeger InfinityInfinityGatewayGateway
DOR,AR
InfusionDevices
B.
Bra
un
B.
Bra
un
Ho
sp
ira
Ho
sp
ira
Ca
rdin
al
Ca
rdin
al
Patient Patient
PolycomPolycomWirelessWirelessPhonePhone
AlarmClient
CapsuleCapsule
SISSISPeriopPeriop
SolutionSolutionDOC
CernerCerner
CareMobileCareMobileTMTM
DOCIOP
IHE PCD ’09 Showcase
![Page 8: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/8.jpg)
8
Considerations for 2010 Showcase
PCD Message should…PCD Message should…
Be fresh (3 years w/ care context!)
Accommodate >2X vendors!
Relevant to Current U.S. HIT Activities (ARRA)
Problem / Profile Focus?
Increased integration with other areas (Alarms, XDS, Continua, …)
![Page 9: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/9.jpg)
9
Considerations for 2010 Showcase
Problem / Problem / ProfileProfile Focus… Focus… Integration with EHR (DEC + RTM)
Patient Safety (ACM & PIV)
Multiple Contexts (HITSP/CmDC & RMON/SDE#2/Home, Emergency Responder, ED/OR/ICU/… )
Quality & Workflow Efficiency (MEM, DPI, IDCO, ICE-PAC, …)
Research & Comparative Effectiveness (RTM, Device Semantics, …)
![Page 10: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/10.jpg)
10
Considerations for 2010 Showcase
Problem / Problem / ProfileProfile Focus… Focus… Integrate “new directions” materials in
core walls (vs. separate area)
![Page 11: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/11.jpg)
11
IHE Patient Care Devices (PCD)
(6” Wide Walls)
Continua IDCO
Multi-Context Connectivity
WAN
EHR / XDS
EHR
Integration
Distributed / Remote Demos
Patient Safety
Quality &
Efficiency
New Directions / Posters / …
![Page 12: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/12.jpg)
![Page 13: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/13.jpg)
13
ARRA Specifics From HITECH Section 3002
1. Technology to protect privacy and security (Protect S&P)
2. A nationwide health information infrastructure that supports exchange of health information (Health Info Infrastructure)
3. The use of certified health record for each person in the US by 2014 (Pervasive Certified Health Record)
4. Technologies to account for disclosures of health information (Disclosure Audit)
![Page 14: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/14.jpg)
14
ARRA Specifics From HITECH Section 3002
5. The use of certified electronic health records to improve the quality of health care, such as by promoting the coordination of health care and improving continuity of health care among health care providers, by reducing medical errors, by improving population health, by reducing health disparities, by reducing chronic disease, and by advancing research and education. (Quality)
6. Technologies that allow individually identifiable health information to be rendered unusable, unreadable, or indecipherable to unauthorized individual (IIHI Unusable)
7. The use of electronic systems to ensure the comprehensive collection of patient demographic data (Demographic Data)
8. Technologies that address the needs of children and other vulnerable populations (Needs of Vulnerable)
![Page 15: Patient Care Devices HIMSS IHE Showcase ’09 Review & ‘10 Planning](https://reader035.vdocument.in/reader035/viewer/2022062221/56649ebe5503460f94bc7b29/html5/thumbnails/15.jpg)
15
IHE Patient Care Devices (PCD)