patio home a - siesta hills
TRANSCRIPT
The right time, the right place, the right size! This beautiful patio home is just what you need, with everything you want. Well-appointed and accented by a highly desirable sunroom, transition to life in this home is a breeze.
TOUR360
Features:
• 2112 Square Feet• 55x50 Build Pad• 2 Bedrooms (1 Master, 1 Guest)• 2 Full Bathrooms (Master, Guest)• 2 Car Garage w/Large Storage Room• Large Kitchen w/Center Island• Walk-in Pantry• Professional Designed Cabinetry• GE Stainless Steel Appliances• Sunroom• Asphalt Shingles• Schmidt Siding (Steel)• Brick Front• Anderson Windows• Forced Air Heat and Central Air Conditioning• Gas Fireplace Unit w/Custom Surround• Custom Design Floorcovering (Budget Amount)• Landscaping (Budget Amount)• Sprinkler System• Concrete Driveway/Patio• City Sewer and Water• HOA fee’s of $250/Month
Architecture + Engineering + Environmental + PlanningSiesta Hills Development
Mankato, Minnesota - 06/03/2020ISG Project No. 23092
ISGinc.com
Patio Home A
ALTERNATE FRONT ELEVATION 1 ALTERNATE FRONT ELEVATION 2 ALTERNATE FRONT ELEVATION 3 ALTERNATE FRONT ELEVATION 4
FIRST FLOOR PLAN
MASTERBEDROOM
KITCHEN
CLOSET
MASTERBATH
SUNROOM
DINING
GARAGE
MUDROOM
LAUNDRY
OFFICE / BEDROOM
BATHROOM
GREAT ROOM
MECH.
PANTRY
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEIL
REQUIREMENTS INCLUDING FRAMINGBRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUAFOR EVERY 300 SQUARE FEET OF ATTIBETWEEN THE SOFFIT AND THE RIDGE.
EXTERIOR· FLASH OVE
· FLASH ALL EPER IRC SEC
· PAN FLASHPRIOR TO IN
· PROVIDE KI
· WINDOW SIEXTERIOR DEXTERIOR R
· WINDOW FALESS THAN 3OR SURFAC
TEMPERED
TEMPERED
ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"
VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO
Theuninck ConstructionSiesta Hills - Patio Home A
New Construction / Mankato, Minnesota
Gable Roof Option
EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"
TEMPERED
EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &
SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8
· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1
· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"
· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE
· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
TEMPERED
TEMPERED
BID D
OCUM
ENTS
- NOT
FOR C
ONST
RUCT
ION
PRO
JEC
T IN
FO
PLANS ISSUED:pricing
IN ASSOCIATION WITH:
GENERAL PLAN NOTES:u EXTERIOR WALLS ARE DRAWN AT 6" ANDDIMENSIONED TO THE OUTSIDE FACE OFSHEATHING, UNLESS NOTED OTHERWISE.u INTERIOR PARTITIONS ARE DRAWN AT 3-1/2"AND DIMENSIONED TO CENTER OF WALL,UNLESS NOTED OTHERWISE.u MASONRY OR ICF WALLS ARE DRAWN ATNOMINAL (NOT ACTUAL) SIZE ANDDIMENSIONED TO THE OUTSIDE FACE OF BLOCKOR FOAM, UNLESS NOTED OTHERWISE.u ANGLED WALLS ON FLOOR PLANS ARE AT A45 DEGREE ANGLE, UNLESS NOTED OTHERWISE.u VERIFY ALL APPLICABLE BUILDING & CODEISSUES PRIOR TO CONSTRUCTION.u VERIFY TOPOGRAPHIC AND SUBSURFACECONDITIONS AND ADAPT FOUNDATION PLANSACCORDINGLY.u CODES GOVERN OVER DRAWINGS.u DIMENSIONS GOVERN OVER SCALE.
PROJECT BY:
const docsrevisedrevisedrevised
Blueprint Home DesignThe Hugo Bldg, 530 North Riverfront Dr, Suite 160Mankato, MN 56001507 [email protected]________________________________________________
DISCLAIMER - Due to the lack of "on site"consultation & supervision, and control over theactual construction process, and because of thevarious local building code requirements &weather conditions, the drafter/designer ASSUMESNO RESPONSIBILITY in the use of these plans forany damages. This includes structural failures dueto any deficiencies, omissions, or errors in thedesign or blueprints. It is recommended youconsult with a local building official or inspectorprior to the start of actual construction.
COPYRIGHT 2018 - This is a copyrighted plan and isthe exclusive property of Blueprint Home Design.All rights are reserved. These plans may not beused, built from, or reproduced in any form or buyany means without the written permission ofBlueprint Home Design.
Theu
ninc
k C
onst
ruct
ion
Sies
ta H
ills -
Patio
Hom
e A
New
Con
stuc
tion
03/24/2020
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
ADHERED (MASOINSTALL PER MFR WEATHER-RESISTIVTWO LAYERS OF GUNDER ADHEREDSTUCCO
Siesta HillsNew Cons
TEMPE
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
TEMPERED
TEMPERED
VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO
Theuninck ConstrucSiesta Hills - Patio Home
New Construction / Mankato, Minn
Gable Roof O
EXTERIOR ELEVATION - RIGHTSCALE: 1/8" = 1'-0"
EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"
EXTERIOR ELEVATION - LEFTSCALE: 1/8" = 1'-0"
TEMPERED
EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &
SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8
· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1
· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"
· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE
· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
TEMPERED
TEMPERED
ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"
A N I M AT I O N & V I R T U A L T O U Rhttps://youtu.be/KLpDyPCtbuohttps://tourmkr.com/f/F19VAURGox/
Animation Virtual Tour
PHOTOS, SITE PLANS & MORE!
VISIT: SIESTAHILLSLIVING.COM
Patio Home A
Architecture + Engineering + Environmental + PlanningSiesta Hills Development
Mankato, Minnesota - 06/03/2020ISG Project No. 23092
ISGinc.com
Patio Home A
ALTERNATE FRONT ELEVATION 1 ALTERNATE FRONT ELEVATION 2 ALTERNATE FRONT ELEVATION 3 ALTERNATE FRONT ELEVATION 4
FIRST FLOOR PLAN
MASTERBEDROOM
KITCHEN
CLOSET
MASTERBATH
SUNROOM
DINING
GARAGE
MUDROOM
LAUNDRY
OFFICE / BEDROOM
BATHROOM
GREAT ROOM
MECH.
PANTRY
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEIL
REQUIREMENTS INCLUDING FRAMINGBRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUAFOR EVERY 300 SQUARE FEET OF ATTIBETWEEN THE SOFFIT AND THE RIDGE.
EXTERIOR· FLASH OVE
· FLASH ALL EPER IRC SEC
· PAN FLASHPRIOR TO IN
· PROVIDE KI
· WINDOW SIEXTERIOR DEXTERIOR R
· WINDOW FALESS THAN 3OR SURFAC
TEMPERED
TEMPERED
ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"
VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO
Theuninck ConstructionSiesta Hills - Patio Home A
New Construction / Mankato, Minnesota
Gable Roof Option
EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"
TEMPERED
EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &
SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8
· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1
· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"
· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE
· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
TEMPERED
TEMPERED
BID
DOCU
MEN
TS -
NOT
FOR
CONS
TRUC
TION
PR
OJE
CT
INFO
PLANS ISSUED:pricing
IN ASSOCIATION WITH:
GENERAL PLAN NOTES:u EXTERIOR WALLS ARE DRAWN AT 6" ANDDIMENSIONED TO THE OUTSIDE FACE OFSHEATHING, UNLESS NOTED OTHERWISE.u INTERIOR PARTITIONS ARE DRAWN AT 3-1/2"AND DIMENSIONED TO CENTER OF WALL,UNLESS NOTED OTHERWISE.u MASONRY OR ICF WALLS ARE DRAWN ATNOMINAL (NOT ACTUAL) SIZE ANDDIMENSIONED TO THE OUTSIDE FACE OF BLOCKOR FOAM, UNLESS NOTED OTHERWISE.u ANGLED WALLS ON FLOOR PLANS ARE AT A45 DEGREE ANGLE, UNLESS NOTED OTHERWISE.u VERIFY ALL APPLICABLE BUILDING & CODEISSUES PRIOR TO CONSTRUCTION.u VERIFY TOPOGRAPHIC AND SUBSURFACECONDITIONS AND ADAPT FOUNDATION PLANSACCORDINGLY.u CODES GOVERN OVER DRAWINGS.u DIMENSIONS GOVERN OVER SCALE.
PROJECT BY:
const docsrevisedrevisedrevised
Blueprint Home DesignThe Hugo Bldg, 530 North Riverfront Dr, Suite 160Mankato, MN 56001507 [email protected]________________________________________________
DISCLAIMER - Due to the lack of "on site"consultation & supervision, and control over theactual construction process, and because of thevarious local building code requirements &weather conditions, the drafter/designer ASSUMESNO RESPONSIBILITY in the use of these plans forany damages. This includes structural failures dueto any deficiencies, omissions, or errors in thedesign or blueprints. It is recommended youconsult with a local building official or inspectorprior to the start of actual construction.
COPYRIGHT 2018 - This is a copyrighted plan and isthe exclusive property of Blueprint Home Design.All rights are reserved. These plans may not beused, built from, or reproduced in any form or buyany means without the written permission ofBlueprint Home Design.
The
un
inc
k C
on
stru
ctio
nSi
est
a H
ills
- P
atio
Ho
me
A
Ne
w C
on
stu
ctio
n
03/24/2020
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
ADHERED (MASOINSTALL PER MFR WEATHER-RESISTIVTWO LAYERS OF GUNDER ADHEREDSTUCCO
Siesta HillsNew Cons
TEMPE
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
TEMPERED
TEMPERED
VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS
SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.
ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO
Theuninck ConstrucSiesta Hills - Patio Home
New Construction / Mankato, Minn
Gable Roof O
EXTERIOR ELEVATION - RIGHTSCALE: 1/8" = 1'-0"
EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"
EXTERIOR ELEVATION - LEFTSCALE: 1/8" = 1'-0"
TEMPERED
EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &
SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8
· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1
· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"
· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE
· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090
EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS
· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.
· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION
· PROVIDE KICK OUT FLASHING AS REQ'D
· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1
· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090
ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN
REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.
· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.
TEMPERED
TEMPERED
ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"
A N I M AT I O N & V I R T U A L T O U Rhttps://youtu.be/KLpDyPCtbuohttps://tourmkr.com/f/F19VAURGox/
Animation Virtual Tour
Front
Master Bedroom
Living Room
Rear
Kitchen
Contact Info:Phone: 507-720-6433
Website: siestahillsliving.comEmail: [email protected]