patio home a - siesta hills

2
The right time, the right place, the right size! This beautiful patio home is just what you need, with everything you want. Well-appointed and accented by a highly desirable sunroom, transition to life in this home is a breeze. TOUR 360 Features: • 2112 Square Feet • 55x50 Build Pad • 2 Bedrooms (1 Master, 1 Guest) • 2 Full Bathrooms (Master, Guest) • 2 Car Garage w/Large Storage Room • Large Kitchen w/Center Island • Walk-in Pantry • Professional Designed Cabinetry • GE Stainless Steel Appliances • Sunroom • Asphalt Shingles • Schmidt Siding (Steel) • Brick Front • Anderson Windows • Forced Air Heat and Central Air Conditioning • Gas Fireplace Unit w/Custom Surround • Custom Design Floorcovering (Budget Amount) • Landscaping (Budget Amount) • Sprinkler System • Concrete Driveway/Patio • City Sewer and Water • HOA fee’s of $250/Month FIRST FLOOR PLAN MASTER BEDROOM KITCHEN CLOSET MASTER BATH SUNROOM DINING GARAGE MUDROOM LAUNDRY OFFICE / BEDROOM BATHROOM GREAT ROOM MECH. PANTRY PHOTOS, SITE PLANS & MORE! VISIT: SIESTAHILLSLIVING.COM Patio Home A

Upload: others

Post on 29-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

The right time, the right place, the right size! This beautiful patio home is just what you need, with everything you want. Well-appointed and accented by a highly desirable sunroom, transition to life in this home is a breeze.

TOUR360

Features:

• 2112 Square Feet• 55x50 Build Pad• 2 Bedrooms (1 Master, 1 Guest)• 2 Full Bathrooms (Master, Guest)• 2 Car Garage w/Large Storage Room• Large Kitchen w/Center Island• Walk-in Pantry• Professional Designed Cabinetry• GE Stainless Steel Appliances• Sunroom• Asphalt Shingles• Schmidt Siding (Steel)• Brick Front• Anderson Windows• Forced Air Heat and Central Air Conditioning• Gas Fireplace Unit w/Custom Surround• Custom Design Floorcovering (Budget Amount)• Landscaping (Budget Amount)• Sprinkler System• Concrete Driveway/Patio• City Sewer and Water• HOA fee’s of $250/Month

Architecture + Engineering + Environmental + PlanningSiesta Hills Development

Mankato, Minnesota - 06/03/2020ISG Project No. 23092

ISGinc.com

Patio Home A

ALTERNATE FRONT ELEVATION 1 ALTERNATE FRONT ELEVATION 2 ALTERNATE FRONT ELEVATION 3 ALTERNATE FRONT ELEVATION 4

FIRST FLOOR PLAN

MASTERBEDROOM

KITCHEN

CLOSET

MASTERBATH

SUNROOM

DINING

GARAGE

MUDROOM

LAUNDRY

OFFICE / BEDROOM

BATHROOM

GREAT ROOM

MECH.

PANTRY

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEIL

REQUIREMENTS INCLUDING FRAMINGBRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUAFOR EVERY 300 SQUARE FEET OF ATTIBETWEEN THE SOFFIT AND THE RIDGE.

EXTERIOR· FLASH OVE

· FLASH ALL EPER IRC SEC

· PAN FLASHPRIOR TO IN

· PROVIDE KI

· WINDOW SIEXTERIOR DEXTERIOR R

· WINDOW FALESS THAN 3OR SURFAC

TEMPERED

TEMPERED

ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"

VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO

Theuninck ConstructionSiesta Hills - Patio Home A

New Construction / Mankato, Minnesota

Gable Roof Option

EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"

TEMPERED

EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &

SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8

· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1

· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"

· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE

· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

TEMPERED

TEMPERED

BID D

OCUM

ENTS

- NOT

FOR C

ONST

RUCT

ION

PRO

JEC

T IN

FO

PLANS ISSUED:pricing

IN ASSOCIATION WITH:

GENERAL PLAN NOTES:u EXTERIOR WALLS ARE DRAWN AT 6" ANDDIMENSIONED TO THE OUTSIDE FACE OFSHEATHING, UNLESS NOTED OTHERWISE.u INTERIOR PARTITIONS ARE DRAWN AT 3-1/2"AND DIMENSIONED TO CENTER OF WALL,UNLESS NOTED OTHERWISE.u MASONRY OR ICF WALLS ARE DRAWN ATNOMINAL (NOT ACTUAL) SIZE ANDDIMENSIONED TO THE OUTSIDE FACE OF BLOCKOR FOAM, UNLESS NOTED OTHERWISE.u ANGLED WALLS ON FLOOR PLANS ARE AT A45 DEGREE ANGLE, UNLESS NOTED OTHERWISE.u VERIFY ALL APPLICABLE BUILDING & CODEISSUES PRIOR TO CONSTRUCTION.u VERIFY TOPOGRAPHIC AND SUBSURFACECONDITIONS AND ADAPT FOUNDATION PLANSACCORDINGLY.u CODES GOVERN OVER DRAWINGS.u DIMENSIONS GOVERN OVER SCALE.

PROJECT BY:

const docsrevisedrevisedrevised

Blueprint Home DesignThe Hugo Bldg, 530 North Riverfront Dr, Suite 160Mankato, MN 56001507 [email protected]________________________________________________

DISCLAIMER - Due to the lack of "on site"consultation & supervision, and control over theactual construction process, and because of thevarious local building code requirements &weather conditions, the drafter/designer ASSUMESNO RESPONSIBILITY in the use of these plans forany damages. This includes structural failures dueto any deficiencies, omissions, or errors in thedesign or blueprints. It is recommended youconsult with a local building official or inspectorprior to the start of actual construction.

COPYRIGHT 2018 - This is a copyrighted plan and isthe exclusive property of Blueprint Home Design.All rights are reserved. These plans may not beused, built from, or reproduced in any form or buyany means without the written permission ofBlueprint Home Design.

Theu

ninc

k C

onst

ruct

ion

Sies

ta H

ills -

Patio

Hom

e A

New

Con

stuc

tion

03/24/2020

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

ADHERED (MASOINSTALL PER MFR WEATHER-RESISTIVTWO LAYERS OF GUNDER ADHEREDSTUCCO

Siesta HillsNew Cons

TEMPE

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

TEMPERED

TEMPERED

VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO

Theuninck ConstrucSiesta Hills - Patio Home

New Construction / Mankato, Minn

Gable Roof O

EXTERIOR ELEVATION - RIGHTSCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - LEFTSCALE: 1/8" = 1'-0"

TEMPERED

EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &

SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8

· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1

· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"

· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE

· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

TEMPERED

TEMPERED

ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"

A N I M AT I O N & V I R T U A L T O U Rhttps://youtu.be/KLpDyPCtbuohttps://tourmkr.com/f/F19VAURGox/

Animation Virtual Tour

PHOTOS, SITE PLANS & MORE!

VISIT: SIESTAHILLSLIVING.COM

Patio Home A

Architecture + Engineering + Environmental + PlanningSiesta Hills Development

Mankato, Minnesota - 06/03/2020ISG Project No. 23092

ISGinc.com

Patio Home A

ALTERNATE FRONT ELEVATION 1 ALTERNATE FRONT ELEVATION 2 ALTERNATE FRONT ELEVATION 3 ALTERNATE FRONT ELEVATION 4

FIRST FLOOR PLAN

MASTERBEDROOM

KITCHEN

CLOSET

MASTERBATH

SUNROOM

DINING

GARAGE

MUDROOM

LAUNDRY

OFFICE / BEDROOM

BATHROOM

GREAT ROOM

MECH.

PANTRY

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEIL

REQUIREMENTS INCLUDING FRAMINGBRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUAFOR EVERY 300 SQUARE FEET OF ATTIBETWEEN THE SOFFIT AND THE RIDGE.

EXTERIOR· FLASH OVE

· FLASH ALL EPER IRC SEC

· PAN FLASHPRIOR TO IN

· PROVIDE KI

· WINDOW SIEXTERIOR DEXTERIOR R

· WINDOW FALESS THAN 3OR SURFAC

TEMPERED

TEMPERED

ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"

VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO

Theuninck ConstructionSiesta Hills - Patio Home A

New Construction / Mankato, Minnesota

Gable Roof Option

EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"

TEMPERED

EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &

SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8

· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1

· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"

· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE

· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

TEMPERED

TEMPERED

BID

DOCU

MEN

TS -

NOT

FOR

CONS

TRUC

TION

PR

OJE

CT

INFO

PLANS ISSUED:pricing

IN ASSOCIATION WITH:

GENERAL PLAN NOTES:u EXTERIOR WALLS ARE DRAWN AT 6" ANDDIMENSIONED TO THE OUTSIDE FACE OFSHEATHING, UNLESS NOTED OTHERWISE.u INTERIOR PARTITIONS ARE DRAWN AT 3-1/2"AND DIMENSIONED TO CENTER OF WALL,UNLESS NOTED OTHERWISE.u MASONRY OR ICF WALLS ARE DRAWN ATNOMINAL (NOT ACTUAL) SIZE ANDDIMENSIONED TO THE OUTSIDE FACE OF BLOCKOR FOAM, UNLESS NOTED OTHERWISE.u ANGLED WALLS ON FLOOR PLANS ARE AT A45 DEGREE ANGLE, UNLESS NOTED OTHERWISE.u VERIFY ALL APPLICABLE BUILDING & CODEISSUES PRIOR TO CONSTRUCTION.u VERIFY TOPOGRAPHIC AND SUBSURFACECONDITIONS AND ADAPT FOUNDATION PLANSACCORDINGLY.u CODES GOVERN OVER DRAWINGS.u DIMENSIONS GOVERN OVER SCALE.

PROJECT BY:

const docsrevisedrevisedrevised

Blueprint Home DesignThe Hugo Bldg, 530 North Riverfront Dr, Suite 160Mankato, MN 56001507 [email protected]________________________________________________

DISCLAIMER - Due to the lack of "on site"consultation & supervision, and control over theactual construction process, and because of thevarious local building code requirements &weather conditions, the drafter/designer ASSUMESNO RESPONSIBILITY in the use of these plans forany damages. This includes structural failures dueto any deficiencies, omissions, or errors in thedesign or blueprints. It is recommended youconsult with a local building official or inspectorprior to the start of actual construction.

COPYRIGHT 2018 - This is a copyrighted plan and isthe exclusive property of Blueprint Home Design.All rights are reserved. These plans may not beused, built from, or reproduced in any form or buyany means without the written permission ofBlueprint Home Design.

The

un

inc

k C

on

stru

ctio

nSi

est

a H

ills

- P

atio

Ho

me

A

Ne

w C

on

stu

ctio

n

03/24/2020

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

ADHERED (MASOINSTALL PER MFR WEATHER-RESISTIVTWO LAYERS OF GUNDER ADHEREDSTUCCO

Siesta HillsNew Cons

TEMPE

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

TEMPERED

TEMPERED

VEHICLE ACCESS DOORS:SHALL MEET ASTM E-330 OR ANSI/DHSMA108 FOR 90 MPH WIND RATING, PLACECOMPLIANCE STICKER ON THE DOORS

SITE FINISH GRADE:SITE SHALL BE GRADED A MIN OF 6" PER10'-0" & AS SUCH TO DRAIN SURFACEWATER AWAY FROM FOUNDATIONWALLS.

ADHERED (MASONRY) VENEER:INSTALL PER MFR INSTRUCTIONS.WEATHER-RESISTIVE BARRIER EQUIVALENT TOTWO LAYERS OF GRADE 'D' PAPER IS REQ'DUNDER ADHERED VENEER SUCH AS STONE ORSTUCCO

Theuninck ConstrucSiesta Hills - Patio Home

New Construction / Mankato, Minn

Gable Roof O

EXTERIOR ELEVATION - RIGHTSCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - REARSCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - LEFTSCALE: 1/8" = 1'-0"

TEMPERED

EXTERIOR ELEVATIONSSCALE: 1/4" = 1'-0" or 1/8" = 1'-0"· ALL EXTERIOR OPENINGS AND INTERSECTIONS OF WALL AND ROOF TO BE FLASHED &

SEALED TO PREVENT THE ENTRY OF WATER IN THE WALL CAVITY PER IRC 703.8

· WINDOW SILL PROTECTION - PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS &WINDOWS, SLOPED TO DRAIN WATER TO THE EXTERIOR R703.8.1

· FINISHED GRADE SHALL FALL FROM FOUNDATION A MINIMUM OF 6" IN THE FIRST 10'-0"

· 6" WOOD/EARTH SEPARATION REQ'D WHILE PROVIDING POSITIVE DRAINAGE AWAYFROM STRUCTURE. BUILDER/HOMEOWNER SHALL COMPLY WITH GRADING PLAN TOASSURE PROPER DRAINAGE

· WINDOW FALL PROTECTION - REQ'D ON ALL OPERABLE WINDOWS LESS THAN 36" ABOVETHE FINISHED FLOOR AND 72" ABOVE GRADE OR SURFACE BELOW R312.2 ASTM 2090

EXTERIOR OPENINGS· FLASH OVER AND CAULK ALL EXTERIOR OPENINGS

· FLASH ALL EXTERIOR OPENINGS & INTERSECTIONS OF WALL & ROOFPER IRC SECTION R703.8.

· PAN FLASHING REQ'D UNDER ALL EXTERIOR DOORS & WINODWSPRIOR TO INSTALLATION

· PROVIDE KICK OUT FLASHING AS REQ'D

· WINDOW SILL PROTECTION: PROVIDE PAN FLASHING UNDER ALLEXTERIOR DOORS & WINDOWS, SLOPED TO DRAIN WATER TO THEEXTERIOR R703.8.1

· WINDOW FALL PROTECTION: REQ'D ON ALL OPERABLE WINDOWSLESS THAN 36" ABOVE THE FINISHED FLOOR AND 72" ABOVE GRADEOR SURFACE BELOW R312.2 ASTM 2090

ROOF PLANSCALE: 1/8" = 1'-0"· REFER TO CHAPTER 8 FOR ROOF CEILING DESIGN

REQUIREMENTS INCLUDING FRAMING, BRACING,BRIDGING AND TRUSS DESIGN.

· VENT ATTIC WITH AT LEAST ONE SQUARE FOOT OF VENTFOR EVERY 300 SQUARE FEET OF ATTIC SPLIT EQUALLYBETWEEN THE SOFFIT AND THE RIDGE.

TEMPERED

TEMPERED

ALTERNATE FRONT ELEVATIONSSCALE: 1/8" = 1'-0"

A N I M AT I O N & V I R T U A L T O U Rhttps://youtu.be/KLpDyPCtbuohttps://tourmkr.com/f/F19VAURGox/

Animation Virtual Tour

Front

Master Bedroom

Living Room

Rear

Kitchen

Contact Info:Phone: 507-720-6433

Website: siestahillsliving.comEmail: [email protected]