PAXFOCUS INSTALLATION AND USER MANUAL 1. TECHNICAL DATA 2 2. PRE-INSTALLATION 3 3. INSTALLATION 5 4. OPERATION 13 5. TESTING 14 Keep for future use OBLICA 200 Argyle St Fitzroy VIC 3065 03 9416 0400

Upload: others

Post on 24-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAXFOCUSINSTALLATION AND USER MANUAL

1. TECHNICAL DATA 2

2. PRE-INSTALLATION 3

3. INSTALLATION 5

4. OPERATION 13

5. TESTING 14

Keep for future use

OBLICA

200 Argyle St Fitzroy VIC 3065

03 9416 0400

Page 2: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 2OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

1. TECHNICAL DATA

DETERMINED UNDER TEST CONDITIONS:

Nominal thermal output 5kW

Efficiency 46,1%

WEIGHT AND DIMENSIONS:

Firebox diameter W950mm x D650mm

Firebox weight 66Kg

Flue diameter 219mm

Flue weight 16Kg/meter

External flue kit Triple skin 200/250/300mm

ø219 mm

FLUE

ø950 mm

360 mm

FIREBOX

PAXFOCUS ATTACHED TONON COMBUSTABLE WALL

Page 3: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 3OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

2. PRE-INSTALLATION

Congratulations on your purchase of the PaxFocus. This appliance should be installed and checked by a qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns please contact Oblica on 03 9416 0400.

The installation process is outlined below: – Determine position of firebox and flue carefully observing the clearances described within this section – Install the suspension bracket – Install the external flue – Install the internal flue and engage the firebox – Ensure the floor has adequate protection

CAUTION:Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance.

WARNING:

• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the relevant building code or codes.

• Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS/NZS 4013.

• Once the flue has been installed and approved by a professional installer, the flue must not be modified in any way.

Page 4: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 4OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

MINIMUM CLEARANCE – INTERNAL

2.1 Clearance from non-combustible surfaces (eg masonry)

There is no minimum clearance required from fully non-combustible surfaces.

Non CombustibleNon Combustible – Masonry WallNon Combustible – Masonry Wall

Combustible

700 350

Com

bustible Wall

Glass

Cement sheet1200150

2.2 Clearance from glass

350mm minimum clearance is required from normal non-combustible glass.150mm minimum clearance is required from toughened glass.

Non CombustibleNon Combustible – Masonry WallNon Combustible – Masonry Wall

Combustible

700 350

Com

bustible Wall

Glass

Cement sheet1200150

2.3 Clearance from combustible surfaces (eg timber joist & plasterboard)

700mm minimum clearance is required on the sides.

Non CombustibleNon Combustible – Masonry WallNon Combustible – Masonry Wall

Combustible

700 350

Com

bustible Wall

Glass

Cement sheet1200150

Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Building Code.

For information on heat shielding please contact our office on 03 9416 0400 or email [email protected].

IMPORTANT: Frames must also be considered. Timber window frames must be treated as combustible surfaces (see 2.3). Aluminium frames can be treated as non-combustible surfaces (see 2.2).

2. PRE-INSTALLATION (CONTINUED)

- 4 -

Distances de sécurité parrapport aux matériauxcombustibles.Safety clearance distances fromcombustible materials.Mindestabstand hinsichtlich derbrennbaren Materialien.Distanze di sicurezza da ogni materialecombustibile.distancias de seguridad con relación alos materiales combustiblesVeilige afstand tot brandbaar materiaal.Sikkerheds afstand til braendbartmateriale.OHUTU KAUGUSPÕLEVMATERJALIDEST.Suojaetäisyydet palava-aineiseenmateriaalin.

.

Biztonsági távolság gyúlékonyanyagoktól.Dro a distance no viegli uzliesmojo iemmateri liem.Leistinas saugus atstumas nuo degimed iag .Distanzi li jridu jithallew minn kullmaterjal li jista jaqbad.Minimalne odleg o ci bezpiecze stwa odmateria ów palnych.Distâncias de segurança em relação aosmateriais combustíveis.Bezpe nostná vzdialenos od hor av chmateriálov.Varnostna razdalja glede na vnetljivemateriale.Säkerhetsavstånd från brännbartmaterial.Bezpe nostní vzdálenost od ho lav chmateriál .

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

700

150

Ventilation Grill

≥1350

Page 5: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 5OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3. INSTALLATION

LOWER FLUE ø219mm.

CONNECTOR

CEILING FLANGE

RUBBER FLASHING

TRIPLE SKIN FLUE200 X 250 X 300(8’ x 10’ x 12’)

CHINAMAN HAT(Anti-Down-Draft device)

PLASTER CEILING MINIMUM GAP

150m

m

25mm

3.1 Installing the suspension bracket

• You must leave a 25mm clearance gap between the flue and the ceiling. This gap will be covered by the ceiling Flange.

• 25mm minimum clearance from the triple skin flue to any combustible material within the roof space

• 40mm minimum overlap of the stainless steel 8” flue into the connector

TYPICAL FLAT ROOF INSTALLATION

Page 6: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 6OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3. INSTALLATION (CONTINUED)

LOWER FLUE ø219mm.

PLASTER CEILINGMINIMUM GAP

25mm

CONNECTOR

CEILING FLANGE

RUBBER FLASHING

TRIPLE SKIN FLUE200 X 250 X 300(8’ x 10’ x 12’)

CHINAMAN HAT(Anti-Down-Draft device)

150m

m

PITCHED ROOF INSTALLATION (CUSTOM MADE FLANGE)

Page 7: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 7OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3. INSTALLATION (CONTINUED)

3.2 Installing the external flue

1. Place the connection piece inside the suspension bracket. This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different diameters.

2. Ensure the triple skin flue is installed as per Australian standards (see diagrams below).

The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a minimum distance of 3 meters from any higher section of roof.

> 40 cm–> 40 cm–

> 40 cm–

> 3 m–

> 120 cm–

> 3 m–

> 120 cm–

> 120 cm–

> 40 cm–> 40 cm–

> 40 cm–

> 3 m–

> 120 cm–

> 3 m–

> 120 cm–

> 120 cm–

The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of 3 meters from any higher section of roof.

PITCHED ROOF INSTALLATION

FLAT ROOF INSTALLATION (LESS THAN 5˚ PITCH)

Page 8: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 8OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3. INSTALLATION (CONTINUED)

2

- 2 -

1 2

43

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

2

- 2 -

1 2

43

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

- 2 -

1 2

43

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

2

- 2 -

1 2

43

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

1

3

2

4

Page 9: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 9OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3. INSTALLATION (CONTINUED)

3

- 3 -

5 6

87

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

3

- 3 -

5 6

87

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

3

- 3 -

5 6

87

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

3

- 3 -

5 6

87

© atelier dominique imbert, 2013.

paxfocus29 07 131307

RRF - 1625

5

7

6

8

Needs more ventilation at rear of heater.

Page 10: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 10OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

3.4 Protecting the floor

• Floor protector MUST EXTEND 300mm in front of fire and 200mm on sides.

• If installed directly on combustible material, the floor protector must be made of a minimum 6mm thick cement sheet. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet, light concrete, etc).

• If the combustible floor is installed on concrete, you can replace the combustible material with non-combustible material laid directly onto the concrete.

Joist

200mm

Insulative board (6mm)+ non combustible finish Non combustible finish

(eg.tiles)

Concrete

Combustible floor (eg. timber)

Joist

200mm 200mm

Insulative board (6mm)+ non combustible finish

Combustible floor (eg. timber)

Combustible floor (eg. timber)

non combustible finishFloor protector /

Combustible floor (eg. timber)

300

200

FIREBOX

WALL

FLOOR PROTECTOR LAID ON TIMBER FLOOR

3. INSTALLATION (CONTINUED)

Joist

200mm

Insulative board (6mm)+ non combustible finish Non combustible finish

(eg.tiles)

Concrete

Combustible floor (eg. timber)

Joist

200mm 200mm

Insulative board (6mm)+ non combustible finish

Combustible floor (eg. timber)

Combustible floor (eg. timber)

non combustible finishFloor protector /

Combustible floor (eg. timber)

300

200

FIREBOX

WALL

FLOOR PROTECTOR LAID ON JOIST

Page 11: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 11OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

Joist

200mm

Insulative board (6mm)+ non combustible finish Non combustible finish

(eg.tiles)

Concrete

Combustible floor (eg. timber)

Joist

200mm 200mm

Insulative board (6mm)+ non combustible finish

Combustible floor (eg. timber)

Combustible floor (eg. timber)

non combustible finishFloor protector /

Combustible floor (eg. timber)

300

200

FIREBOX

WALL

FLOOR PROTECTOR LAID ON CONCRETE

TOP VIEW

3. INSTALLATION (CONTINUED)

Joist

200mm

Insulative board (6mm)+ non combustible finish Non combustible finish

(eg.tiles)

Concrete

Combustible floor (eg. timber)

Joist

200mm 200mm

Insulative board (6mm)+ non combustible finish

Combustible floor (eg. timber)

Combustible floor (eg. timber)

non combustible finishFloor protector /

Combustible floor (eg. timber)

300

200

FIREBOX

WALL IMPORTANT: Cement sheet section must be ventilated (Opening on both sides)

Page 12: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 12OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

4. OPERATION

4.1 What you should burn

• Untreated, air dried hardwood • Split logs with a humidity content of less than 20%

4.2 Do not burn

• Trash• Painted plastic • Coated or preservative treated wood• Waste or black coal • Inflammable liquids • Fire gels • Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney).

WARNING:

• Do not use flammable liquids or aerosols to start or rekindle the fire.

• Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating.

• Do not store fuel within prescribed installation clearance distances.

• The use of some types of preservative-treated woods as a fuel can be hazardous.

IMPORTANT: • Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee.• The maximum load capacity for the PaxFocus is 20kg of wood.• Burning only seasoned hardwood helps to protect the environment and lower emissions.

For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected].

Page 13: PAXFOCUS · 2020-01-24 · materi liem. Leistinas saugus atstumas nuo degi med iag . Distanzi li jridu jithallew minn kull materjal li jista jaqbad. Minimalne odleg o ci bezpiecze

PAGE 13OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL

5. TESTING

TEST REPORT Nº ATL17-10

TESTING LABORATORY: AHHA Testing Laboratory 6/26 Stirling st Thebarton, SA 5031 08 8351 8056

MANUFACTURER: Focus – Atelier Dominique Imbert

MODEL: PaxFocus open style fireplace Extended to PaxFocus by Vipac Laboratory WORK REQUESTED: Measure CO2 levels as outlined in AS/NZS 4013:1999 to determine if appliance is excluded from full testing to this standard.

TEST DATES: 09/06/2010

RESULTS: The maximum carbon dioxide output by the appliance during the high burn rate prescribed in AS/NZS 4013:1999 was 3.75%.

CONCLUSION: This appliance meets the requirements of AS/NZS 4013:1999 section 1.2.3 (f) and is classified as an excluded appliance.