pb 22359 en - 03 - gewiss 22359 en cata prog light 0316_en.indd 10 15/04/16 11:44. ... id 4 5 20 id...

90
SOLUTIONS FOR sport facilities lighting 2nd EDITION

Upload: others

Post on 28-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

SOLUTIONS FOR

sport facilities lighting2nd EDITION

PB 2

2359

EN

- 03

.16

GEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - Italy Tel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies / VAT / Tax code (IT) 00385040167 - REA 107496 - Share capital 60,000,000.00 EUR fully paid up

PB 22359 EN Cover dorso 0316.indd 1-3 15/04/16 09:31

Page 2: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

GEWISS was founded more than 40 years ago and, right from the start, the search for quality and the development of first class solutions have been the guiding values behind every action and decision. Over the years, this innovative vocation has taken the form of a business model based above all on continuous investment in R&D.The constant testing of new materials and technologies, the global vision of the lighting concept and the formalisation of design elements bearing the unmistakable Italian design - these are the deepest and most intimate features of GEWISS lighting solutions. The perfect chemistry has enabled GEWISS to become a global partner for the creation of lighting systems for indoor and outdoor sports facilities.The range includes floodlights, high bays and watertight luminaires designed to offer the best lighting performance for sports events at every level, from professional to semi-professional and amateur.

3

PB 22359 EN Cata prog Light 0316_EN.indd 3 15/04/16 11:43

Page 3: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

FOOTBALL BASKETBALL VOLLEYBALL TENNIS

STANDARD FOOTBALLAverage lighting

[lx] Page

500 10

200 12

75 14

7-A-SIDE FOOTBALLAverage lighting

[lx] Page

200 16

75 18

5-A-SIDE FOOTBALLAverage lighting

[lx] Page

200 20

75 22

Average lighting [lx]

Page

200 30

75 32

Average lighting [lx]

Page

500 40

200 42

75 44

Average lighting [lx]

Page

300 52

200 54

5-A-SIDE FOOTBALLAverage lighting

[lx] Page

750 24

500 26

200 28

Average lighting [lx]

Page

750 34

500 36

200 38

Average lighting [lx]

Page

750 46

500 48

200 50

Average lighting [lx]

Page

750 56

500 58

300 60

OU

TDO

OR

IND

OO

R

4

Contents

PB 22359 EN Cata prog Light 0316_EN.indd 4 15/04/16 11:43

Page 4: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

SWIMMING SQUASH BOCCE COMPLEMENTARY AREAS

Average lighting [lx]

Page

300 62

200 64

Page

An overview of the GEWISS range

82

Example of sports facilities layout

84

List of products

1.1 Car park1.2 Northern

stand1.3 Southern

stand1.4 Access path

86

1.5 Storehouse1.6 Local team

changing rooms

1.7 Guest team changing rooms

87

1.8 Technical premises

1.9 Office88

1.10 Referee 1 changing room

1.11 Referee 2 changing room

89

Average lighting [lx]

Page

500 66

300 68

200 70

Average lighting [lx]

Page

300 78

200 80

Average lighting [lx]

Page

750 72

500 74

300 76

5

PB 22359 EN Cata prog Light 0316_EN.indd 5 15/04/16 11:44

Page 5: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

Smart [4] 2.0 is the new lighting device whose strength lies in its multi-faceted nature. It can provide sustainable light for the most varied contexts (from industrial to sports, indoor and outdoor) where the crucial aspect is the lighting performance. It can be a floodlight, high bay or

Smart [4] 2.0

luminaire, offering different photometry ranges depending on the context. The horizontal and vertical modularity of this product combines with easy installation and maintenance, using “green” materials and displaying the unmistakable Italian style.

6

GEWISS solutions

PB 22359 EN Cata prog Light 0316_EN.indd 6 15/04/16 11:44

Page 6: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

Lighting boundaries are pushed further with the Stadium range: outdoor floodlights for lighting particularly large areas. Lamps with a maximum power of 2000W, combined with a symmetrical or asymmetrical, diffused or restricted optic. Bodies in die-cast aluminium treated with trivalent passivation and painted with polyester powders. High bays in 99.85 aluminium, anodised and polished. To guarantee long-lasting performance results, all the versions are fitted with an anti-condensation device in Gore-Tex® for internal pressure compensation.

Smart [3] is the new range of LED watertight luminaires that completes the Smart selection. Ideal for use in installation contexts with heights of less than 4 metres, the latest GEWISS lighting devices stand out for their elegant Italian design, excellent energy performance, optimum impact resistance and quick and easy installation.

Stadium Smart [3]

7

PB 22359 EN Cata prog Light 0316_EN.indd 7 15/04/16 11:44

Page 7: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

We provide light for sport

This collection aims to spread a lighting culture from the design and installation viewpoint, providing the basic information needed to create sport facilities lighting systems of the best quality, from design through to installation.Apart from skilled professionals and qualified installers, these solutions will also be useful for those wanting to acquire further knowledge about the design and application aspects of lighting, such as students of professional technical colleges and aspiring lighting designers.The design sheets refer to sports fields of standard sizes, and the projects were developed in compliance with EN 12193, envisaging various levels of lighting to meet the needs of a range of activities from amateur to semi-professional and professional level.To provide complete support, beyond just the basic lighting project, the designs are accompanied by a layout illustrating the electrotechnical aspects of the installation, indicating the characteristics of the system components (e.g. the control panel, auxiliary circuits and protective or command circuit breakers).

8

Lighting for sports facilities

PB 22359 EN Cata prog Light 0316_EN.indd 8 15/04/16 11:44

Page 8: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

9

PB 22359 EN Cata prog Light 0316_EN.indd 9 15/04/16 11:44

Page 9: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

20-5

-10

-15

-20

Ass

e y

(m)

-40

-35

-30

-25

2535

4030

0 5 10 15 20-5-10-15-20Asse x (m)

-25-30-35-40-45-50-55 25 30 35 40 45 50 55

1 11 1 1

1 11 1 1

1 11 1 1

1 11 1 1

1 11 1 1

1 11 1 1

1 11 1 1

1 11 1 1

1

1

1

1

1

1

1

1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 2000W/842

Lamp flux (lm) 220,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 28

Number of floodlights 48

Number of floodlights per high mast 12

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT - 2000W - GW 84 668

FLOODLIGHT POSITIONINGLighting

towerPosition of

devices in XPosition of devices in Y

Position of devices in Z

Device rotation X°; Y°; Z°

1 -33.00 -38.00 27.00 0°; 0°; 140°

1 -32.00 -38.00 27.00 0°; 0°; 140°

1 -31.00 -38.00 27.00 0°; 0°; 135°

1 -30.00 -38.00 27.00 0°; 0°; 55°

1 -29.00 -38.00 27.00 0°; 0°; 50°

1 -28.00 -38.00 27.00 0°; 0°; 50°

1 -33.00 -37.00 28.00 0°; 0°; 140°

1 -32.00 -37.00 28.00 0°; 0°; 140°

1 -31.00 -37.00 28.00 0°; 0°; 135°

1 -30.00 -37.00 28.00 0°; 0°; 55°

1 -29.00 -37.00 28.00 0°; 0°; 50°

1 -28.00 -37.00 28.00 0°; 0°; 50°

GRID 21x15EAv [lx] 594

Emin/EAv 0.71

GR 30

CRI 80

No. floodlights 48

floodlight height [m] 27-28

KEY400.0 lx500.0 lx

600.0 lx

700.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

I 500 0.7 50 60

PLAY AREA DIMENSIONSLength [m] 105Width [m] 65Grid points (length) 21Grid points (width) 15

10

OU

TD

OO

R

REQUISITES

Standard football - 500 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

11

PB 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44

Page 10: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

264

171

AUX

1

2

3Id

4

5

20Id

18

19

Id16

17

Id14

15

Id12

13

Id10

11

Id8

9

Id6

7

Id

NEUTRO

FASE

Kpp1P1 P2 Kpp2 P3 Kpp3 P4 Kpp4 P5 Kpp5 P6 Kpp6 P7 Kpp7 P8 Kpp8

Km1aKpp1 Kpp2 Km1b Kpp3 Km2a Kpp4 Km2b Kpp5 Km3a Kpp6 Km3b Kpp7 Km4a Kpp8 Km4b

STANDARD ELECTRICAL SCHEME -System power: 96kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast

1 - Km 1aHigh mast 1 - Km 1b

High mast 2 - Km 2a

High mast 2 - Km 2b

High mast 3 - Km 3a

High mast 3 - Km 3b

High mast 4 - Km 4a

High mast 4 - Km 4b

Auxiliaries circuit

Power 96.000 kW 0.000 kW 12.000 kW 12.000 kW 12.000 kW 12.000 kW 12.000 kW 12.000 kW 12.000 kW 12.000 kW 0.000 kW

Operating current Ib [A] 154.14 0.00 19.27 19.27 19.27 19.27 19.27 19.27 19.27 19.27 0.00

Rated current In [A] 200.00 100.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 6.00

Article descriptionMTX250 N

36kA 4P 200A TM1

Disconnect-able fuse

holder 3P+N 22x58 690V

100A

Surge protec-tive device 3P+N 25kA Type 1+2

Triple red signalling

lamp with fuse holder 230V

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MT60 MCB D25 4P + BD 4P 63A

30mA A-IR Contactor 4NO

230V 24A

MDC60 C6 2P Id=30mA AC

Code GW D7 216 GW 96 314 GW D6 405 GW 96 592 GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715

GW 92 489 + GW D6 715 GW 94 125

Breaking capacity [kA] 36.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586 GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 45 057 CVX630M - Structure 600x1600 1GW 45 077 CVX630M - Pair of side panels 1GW 45 157 CVX630M - Glass door IP55 1GW 45 202 Kit for modular devices on DIN rail 600x200 5GW 45 273 CVX630K/M Kit for MTX250 600x200 1GW 45 304 CVX630K Blank front panel 2GW 45 411 Double DIN rail 24M 1GW 45 526 Pair of supports for terminal block 1GW 45 541 4-pole divider 250A 1

Standard puSh-buttonpanel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 105 12-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 8

GW 74 501 1 NO contact 10A 250V 8

GW 74 511 Lamp-holder - BA95 coupling 8

GW 74 518 Lamp - BA95 coupling 8

GW 74 521 Black cap 4

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW D7 216 MCB 4P MTX250 N 36KA 200A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 489 MCB 4P D25 10KA 4M 8

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 8

GW D6 715 Contactor 230V 4NO 24A 8

GW D6 644 Latching relay 1NO 16A 230V 8

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

11

PB 22359 EN Cata prog Light 0316_EN.indd 11 15/04/16 11:44

Page 11: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

20-5

-10

-15

-20

Ass

e y

(m)

-40

-35

-30

-25

2535

4030

0 5 10 15 20-5-10-15-20Asse x (m)

-25-30-35-40-45-50-55 25 30 35 40 45 50 55

1

1

1

1

11

111 1

1 1 11

1 1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 2000W/842

Lamp flux (lm) 220,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 27

Number of floodlights 16

Number of floodlights per high mast 4

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT - 2000W - GW 84 668

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -27.00 -36.00 0°; 0°; 50°

1 -28.00 -36.00 0°; 0°; 60°

1 -29.00 -36.00 0°; 0°; 135°

1 -30.00 -36.00 0°; 0°; 140°

4 27.00 -36.00 0°; 0°; 130°

4 28.00 -36.00 0°; 0°; 120°

4 29.00 -36.00 0°; 0°; 45°

4 30.00 -36.00 0°; 0°; 40°

GRID 21x15EAv [lx] 216

Emin/EAv 0.65

GR 30

CRI 80

No. floodlights 16

floodlight height [m] 27

KEY 150.0 lx

200.0 lx250.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 200 0.6 50 60

PLAY AREA DIMENSIONSLength [m] 105Width [m] 65Grid points (length) 21Grid points (width) 15

12

11O

UT

DO

OR

REQUISITES

Standard football - 200 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 12 15/04/16 11:44

Page 12: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

3

4 5

6

7

8

9

10

11

12

13IdIdIdIdId

AUX

6 7 8

STANDARD ELECTRICAL SCHEME -System power: 32kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 32.000 kW 0.000 kW 8.000 kW 8.000 kW 8.000 kW 8.000 kW 8.000 kW 8.000 kW 8.000 kW 8.000 kW 0.000 kW

Operating current Ib [A] 51.38 0.00 12.85 12.85 12.85 12.85 12.85 12.85 12.85 12.85 0.00

Rated current In [A] 63.00 50.00 16.00 24.00 16.00 24.00 16.00 24.00 16.00 24.00 6.00

Article description MTHP160 D63 4P

Disconnectable fuse holder 3P+N 22x58

690V 50A

Surge protec-tive device 3P+N 25kA Type 1+2

Triple red signalling

lamp with fuse holder 230V

MCB MT60 D16 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D16 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D16 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D16 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MDC60 C6 2P Id=30mA AC

Code GW 93 396 GW 96 314 GW D6 405 GW 96 592 GW 92 487 GW D6 715 GW 92 487 GW D6 715 GW 92 487 GW D6 715 GW 92 487 GW D6 715 GW 94 125

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 515MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 93 396 MCB 4P D63 10KA 6M 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 487 MCB 4P D16 6KA 4M 4

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 4

GW D6 715 Contactor 230V 4NO 24A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

13

PB 22359 EN Cata prog Light 0316_EN.indd 13 15/04/16 11:44

Page 13: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

55504540353025-55 -50 -45 -40 -35 -30 -25Asse x (m)

-20 -15 -10 -5 20151050

3040

3525

-25

-30

-35

-40

Ass

e y

(m)

-20

-15

-10

-520

1510

50

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 2000W/842

Lamp flux (lm) 220,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 25

Number of floodlights 8

Number of floodlights per high mast 2

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT - 2000W - GW 84 668

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -29.75 -36.00 0°; 0°; 140°

1 -28.75 -36.00 0°; 0°; 35°

2 -29.75 36.00 0°; 0°; -140°

2 -28.75 36.00 0°; 0°; -35°

3 29.75 36.00 0°; 0°; -40°

3 28.75 36.00 0°; 0°; -145°

4 29.75 -36.00 0°; 0°; 40°

4 28.75 -36.00 0°; 0°; 145°

GRID 21x15EAv [lx] 99

Emin/EAv 0.61

GR 30

CRI 80

No. floodlights 8

floodlight height [m] 25

KEY60.0 lx80.0 lx

100.0 lx

120.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 75 0.5 55 20

PLAY AREA DIMENSIONSLength [m] 105Width [m] 65Grid points (length) 21Grid points (width) 15

14

11O

UT

DO

OR

REQUISITES

Standard football - 75 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 14 15/04/16 11:44

Page 14: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

R

2

3

4 5

6

7

8

9

10

11

12

13

Id

AUX

STANDARD ELECTRICAL SCHEME -System power: 16kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 16.000 kW 0.000 kW 4.000 kW 4.000 kW 4.000 kW 4.000 kW 4.000 kW 4.000 kW 4.000 kW 4.000 kW 0.000 kW

Operating current Ib [A] 25.68 0.00 6.42 6.42 6.42 6.42 6.42 6.42 6.42 6.42 0.00

Rated current In [A] 40.00 40.00 10.00 24.00 10.00 24.00 10.00 24.00 10.00 24.00 6.00

Article description

MT100 D40 4P +

BD 4P 63A 30mA A-IR

Disconnectable fuse holder 3P+N 22x58

690V 40A

Surge protec-tive device 3P+N 25kA Type 1+2

Triple red signalling

lamp with fuse holder 230V

MT60 D10 4P

Contactor4 NO

230V AC/DC 24A - 2M

MT60 D10 4P

Contactor4 NO

230V AC/DC 24A - 2M

MT60 D10 4P

Contactor 4 NO

230V AC/DC 24A - 2M

MT60 D10 4P

Contactor 4 NO

230V AC/DC 24A - 2M

MTC60 C6 1P+N

Code GW 92 791 GW 96 314 GW D6 405 GW 96 592 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 90 225

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 + GW 90 893

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 8M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 791 MCB 4P D40 10KA 4M 1

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 1

GW 90 893 Adjustable reset RM TOP 4P 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 486 Compact MCB 4P D10 6KA 4M 4

GW D6 715 Contactor 230V 4NO 24A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 90 225 Compact MCB 1P+N C 6 6KA 1M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

15

PB 22359 EN Cata prog Light 0316_EN.indd 15 15/04/16 11:44

Page 15: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

-30-35 30 35

05

1015

-5-1

0-1

5

Ass

e y

(m)

-20

-25

2025

11 11

11 11 1

11

1

430

660

770

630170170

ø14 ø14

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 16

Number of floodlights 12

Number of floodlights per high mast 3

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT 1000W - GW 84 667

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -16.50 -23.00 0°; 0°; 140°

1 -15.50 -23.00 0°; 0°; 100°

1 -14.50 -23.00 0°; 0°; 50°

2 -16.50 23.00 0°; 0°; -140°

2 -15.50 23.00 0°; 0°; -100°

2 -14.50 23.00 0°; 0°; -50°

3 16.50 23.00 0°; 0°; -40°

3 15.50 23.00 0°; 0°; -80°

3 14.50 23.00 0°; 0°; -130°

4 16.50 -23.00 0°; 0°; 40°

4 15.50 -23.00 0°; 0°; 80°

4 14.50 -23.00 0°; 0°; 130°

GRID 19x13EAv [lx] 211

Emin/EAv 0.67

GR 30

CRI 80

No. floodlights 12

floodlight height [m] 16

PROPOSED SOLUTION

KEY 150.0 lx

200.0 lx250.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 200 0.6 50 60

PLAY AREA DIMENSIONSLength [m] 60Width [m] 40Grid points (length) 19Grid points (width) 13

16

7O

UT

DO

OR

REQUISITES

7-a-side football - 200 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 16 15/04/16 11:44

Page 16: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

3

4 5

6

7

8

9

10

11

12

13IdIdIdIdId

AUX

STANDARD ELECTRICAL SCHEME -System power: 12kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 12.000 kW 0.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 0.000 kW

Operating current Ib [A] 19.27 0.00 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 0.00

Rated current In [A] 32.00 50.00 10.00 24.00 10.00 24.00 10.00 24.00 10.00 24.00 6.00

Article description MT100 D32 4P

Disconnectable fuse holder 3P+N 22x58

690V 50A

Surge protec-tive device 3P+N 25kA Type 1+2

Triple red signalling

lamp with fuse holder 230V

MCB MT60D10 4P +

BD 4P 63A 30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A 30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A 30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A 30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MDC60 C6 2P Id=30mA AC

Code GW 92 790 GW 96 314 GW D6 405 GW 96 592 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 94 125

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800x585x300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 515MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 8M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 790 MCB 4P D32 10KA 4M 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 486 MCB 4P D10 6KA 4M 4

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 4

GW D6 715 Contactor 230V 4NO 24A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

17

PB 22359 EN Cata prog Light 0316_EN.indd 17 15/04/16 11:44

Page 17: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

-30-35 30 35

05

1015

-5-1

0-1

5

Ass

e y

(m)

-20

-25

2025

11 11

11 11

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 17

Number of floodlights 8

Number of floodlights per high mast 2

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 75 0.5 55 20

ASYMMETRICAL STADIUM FLOODLIGHT 1000W GW 84 667

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -15.00 -23.00 0°; 0°; 60°

1 -16.00 -23.00 0°; 0°; 135°

2 -15.00 23.00 0°; 0°; -60°

2 -16.00 23.00 0°; 0°; -135°

3 15.00 23.00 0°; 0°; -120°

3 16.00 23.00 0°; 0°; -45°

4 15.00 -23.00 0°; 0°; 120°

4 16.00 -23.00 0°; 0°; 45°

GRID 19x13EAv [lx] 140

Emin/EAv 0.65

GR 30

CRI 80

No. floodlights 8

floodlight height [m] 17

KEY 80.0 lx

100.0 lx120.0 lx140.0 lx160.0 lx180.0 lx

PLAY AREA DIMENSIONSLength [m] 60Width [m] 40Grid points (length) 19Grid points (width) 13

18

7O

UT

DO

OR

REQUISITES

7-a-side football - 75 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 18 15/04/16 11:44

Page 18: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

R

2

3

4 5

6

7

8

9

10

11

12

13

Id

AUX

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

STANDARD ELECTRICAL SCHEME -System power: 8kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 8.000 kW 0.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 0.000 kW

Operating current Ib [A] 19.32 0.00 9.66 9.66 9.66 9.66 9.66 9.66 9.66 9.66 0.00

Rated current In [A] 20.00 20.00 16.00 20.00 16.00 20.00 16.00 20.00 16.00 20.00 6.00

Article description

MCB MT100 D20 4P +

BD 4P 63A 30mA A-IR

Disconnectable fuse holder 3P+N 22x58 690V 100A

Surge protec-tive device 3P+N 25kA Type 1+2

Triple red signalling

lamp with fuse holder 230V

MT60 D16 2P

Contactor 2 NO

230V AC 20A -1M

MT60 D16 2P

Contactor 2 NO

230V AC 20A -1M

MT60 D16 2P

Contactor 2 NO

230V AC 20A -1M

MT60 D16 2P

Contactor 2 NO

230V AC 20A -1M

MTC60 C6 1P+N

Code GW 92 788 GW 96 314 GW D6 405 GW 96 592 GW 92 447 GW D6 703 GW 92 447 GW D6 703 GW 92 447 GW D6 703 GW 92 447 GW D6 703 GW 90 225

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 + GW 90 893

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 205 Polyester board with window 650x515x250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM 1

GW 46 437 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 532 F Double rail 24M 1

GW 44 696 4-pole terminal block 4M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 788 MCB 4P D20 10KA 4M 1

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 1

GW 90 893 Adjustable reset RM TOP 4P 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 447 MCB 2P D16 6KA 2M 4

GW D6 703 Contactor 230V 2NO 20A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 90 225 Compact MCB 1P+N C 6 6KA 1M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

19

PB 22359 EN Cata prog Light 0316_EN.indd 19 15/04/16 11:44

Page 19: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 1

1 1

1

1

1

1

1

11

1

1

1 1

1

751 99

504

533

PROPOSED SOLUTION

CALCULATION RESULTS

GRID 13x7EAv [lx] 205

Emin/EAv 0.75

GR 17

CRI 80

No. floodlights 16

floodlight height [m] 12

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 12

Number of floodlights 16

Number of floodlights per high mast 4

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -13.00 -11.50 0°; 0°; 130°

1 -12.00 -11.50 0°; 0°; 100°

1 -11.00 -11.50 0°; 0°; 70°

1 -10.00 -11.50 0°; 0°; 35°

4 13.00 -11.50 0°; 0°; 50°

4 12.00 -11.50 0°; 0°; 80°

4 11.00 -11.50 0°; 0°; 110°

4 10.00 -11.50 0°; 0°; 145°

KEY 150.0 lx

200.0 lx

300.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 200 0.6 50 60

PLAY AREA DIMENSIONSLength [m] 40Width [m] 20Grid points (length) 13Grid points (width) 7

20

5O

UT

DO

OR

REQUISITES

5-a-side football - 200 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 20 15/04/16 11:45

Page 20: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 3.8kW, three-phase

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 3.800 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.000 kW

Operating current Ib [A] 6.00 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 0.00

Rated current In [A] 32.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 6.00

Article descriptionControl switch disconnector

4P 32A

Surge protective device 3P+N

25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230VAC/ 220V DC -2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230VAC/ 220V DC -2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MDC60 C6 2PId=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 089 MCB 4P C25 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 3.5M 4

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

21

PB 22359 EN Cata prog Light 0316_EN.indd 21 15/04/16 11:45

Page 21: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 1

1 1

1

1

1

1

1 1

1 1

741

700

74

282

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 116

Lumen output (lm) 12,780

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 10

Number of floodlights 12

Number of floodlights per high mast 3

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 156 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -13.00 -11.00 0°; 0°; 135°

1 -12.00 -11.00 0°; 0°; 90°

1 -13.00 -11.00 0°; 0°; 35°

4 10.00 -11.00 0°; 0°; 145°

4 11.00 -11.00 0°; 0°; 90°

4 12.00 -11.00 0°; 0°; 45°

GRID 13x7EAv [lx] 83

Emin/EAv 0.61

GR 18

CRI 80

No. floodlights 12

floodlight height [m] 10

KEY60.0 lx90.0 lx

120.0 lx

150.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 75 0.5 55 20

PLAY AREA DIMENSIONSLength [m] 40Width [m] 20Grid points (length) 13Grid points (width) 7

22

5O

UT

DO

OR

REQUISITES

5-a-side football - 75 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 22 15/04/16 11:45

Page 22: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

1

23

4 5

10 11

6 7 8 9 12

STANDARD ELECTRICAL SCHEME -System power: 1.4kW, single-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod. EN 50022 1

GW 46 204 Polyester board with window 650X405X200 1

GW 46 421 F Panel without windows 18 mod. 3

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 2

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 1.400 kW 0.350 kW 0.350 kW 0.350 kW 0.350 kW 0.350 kW 0.350 kW 0.350 kW 0.350 kW 0.000 kW

Operating current Ib [A] 6.80 1.70 1.70 1.70 1.70 1.70 1.70 1.70 1.70 0.00

Rated current In [A] 32.00 16.00 25.00 16.00 25.00 16.00 25.00 16.00 25.00 6.00

Article descriptionControl switch disconnector

2P 32A

Surge protec-tive device 1P+N 25kA

Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse

holder 230V 10.3x38 - 3M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 92 047 GW D6 712 GW 92 047 GW D6 712 GW 92 047 GW D6 712 GW 92 047 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 4.50

RCCB GW 94 566 GW 94 566 GW 94 566 GW 94 566

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 92 047 MCB 2P C16 6KA 2M 4

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 566 Residual current device 2P IN<63A Immun. A/0.03 2M 4

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 4

23

PB 22359 EN Cata prog Light 0316_EN.indd 23 15/04/16 11:45

Page 23: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 11 1 1

1 11 1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

11 1

11

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 52

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -21.00 -11.00 0°; 0°; 90°

2 -20.00 -11.00 0°; 0°; 90°

3 -19.00 -11.00 0°; 0°; 90°

4 -17.50 -11.00 0°; 0°; 90°

5 -16.00 -11.00 0°; 0°; 90°

6 -14.50 -11.00 0°; 0°; 90°

7 -12.50 -11.00 0°; 0°; 90°

8 -10.00 -11.00 0°; 0°; 90°

9 -8.00 -11.00 0°; 0°; 90°

10 -6.00 -11.00 0°; 0°; 90°

11 -4.00 -11.00 0°; 0°; 90°

12 -2.50 -11.00 0°; 0°; 90°

13 -1.00 -11.00 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 15x9EAv [lx] 778

Emin/EAv 0.85

CRI 80

No. floodlights 52

floodlight height [m] 10

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

KEY 500.0 lx

600.0 lx700.0 lx800.0 lx900.0 lx

1000.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 750 0.7 60

PLAY AREA DIMENSIONSLength [m] 40Width [m] 20Grid points (length) 15Grid points (width) 9

24

REQUISITES

5IN

DO

OR

5-a-side football - 750 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 24 15/04/16 11:45

Page 24: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

STANDARD ELECTRICAL SCHEME -System power: 12.0kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 4

GW 46 423 F Panel without windows 28 mod. 1

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3GW 92 093 MCB 4P C63 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 176 Control switch disconnector 4P 63A AC22B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1GW D6 724 Contactor 40A 4NO 230V 3M 4

Standard auxiliarieS circuit

Line description Main device Lamp Line 1 km1 Line 2 km2 Line 3 km3 Line 4 km4 Auxiliaries line

Power 12.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 0.000 kW

Operating current Ib [A] 19.20 4.80 4.80 4.80 4.80 4.80 4.80 4.80 4.80 0.00

Rated current In [A] 63.00 63.00 40.00 63.00 40.00 63.00 40.00 63.00 40.00 6.00

Article description

Control switch discon-

nector 4P63A

Surge protec-tive device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling

lamp with fuse holder 230V 10.3x38 - 5M

MT60 C63 4P+

BD 4P 63A 30mA

S

Contactor 40A4NO -

230V AC/220V DC -

3M

MT60 C634P+

BD 4P 63A 30mA

S

Contactor 40A4NO -

230V AC/220V DC -

3M

MT60 C63 4P+

BD 4P 63A 30mA

S

Contactor 40A4NO -

230V AC/220V DC -

3M

MT60 C63 4P+

BD 4P 63A 30mA

S

Contactor 40A4NO -

230V AC/220V DC -

3M

MDC60 C6 2PId=30mA AC

Code GW 96 176 GW D6 405 GW 96 592 GW 92 093 GW D6 724 GW 92 093 GW D6 724 GW 92 093 GW D6 724 GW 92 093 GW D6 724 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW94 532 GW 94 532 GW 94 532 GW 94 532

25

PB 22359 EN Cata prog Light 0316_EN.indd 25 15/04/16 11:45

Page 25: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 1 1 1 11 1 11

1 1 1 1 11 1 11 1

11

1

1

1

1

1

1

1

1

11 1

1 1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 34

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 15x9EAv [lx] 504

Emin/EAv 0.83

CRI 80

No. floodlights 34

floodlight height [m] 10

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 - 21.00 -11.00 0°; 0°; 90°

2 - 19.00 -11.00 0°; 0°; 90°

3 - 17.00 -11.00 0°; 0°; 90°

4 - 15.00 -11.00 0°; 0°; 90°

5 - 13.00 -11.00 0°; 0°; 90°

6 - 10.00 -11.00 0°; 0°; 90°

7 - 6.00 -11.00 0°; 0°; 90°

8 - 3.00 -11.00 0°; 0°; 90°

9 0.00 -11.00 0°; 0°; 90°

KEY 300.0 lx

400.0 lx500.0 lx600.0 lx700.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 40Width [m] 20Grid points (length) 15Grid points (width) 9

26

REQUISITES

5IN

DO

OR

5-a-side football - 500 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 26 15/04/16 11:45

Page 26: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

STANDARD ELECTRICAL SCHEME -System power: 8.0kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp Line1 km1 Line

2 km2 Line3 km3 Line

4 km4 Auxiliaries line

Power 8.000 kW 2.100 kW 2.100 kW 1.900 kW 1.900 kW 2.100 kW 2.100 kW 1.900 kW 1.900 kW 0.000 kW

Operating current Ib [A] 12.60 3.30 3.30 3.00 3.00 3.30 3.30 3.00 3.00 0.00

Rated current In [A] 40.00 40.00 25.00 40.00 25.00 40.00 25.00 40.00 25.00 6.00

Article description MT100 D40 4P

Surge protec-tive device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling

lamp with fuse holder 230V 10.3x38 - 5M

MT60 C40 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C40 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C404P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C40 4P +

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MDC60 C6 2PId=30mA AC

Code GW 92 791 GW D6 405 GW 96 592 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 091 MCB 4P C40 6KA 4M 4

GW 92 791 MCB 4P D40 10KA 4M 1

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

27

PB 22359 EN Cata prog Light 0316_EN.indd 27 15/04/16 11:45

Page 27: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

-5-1

0-1

5

Ass

e y

(m)

-25 250 5 10 15 20-5-10-15-20Asse x (m)

1 1 1 1 1

1 1 1 1 1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHTGW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 14

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -19.00 -11.00 0°; 0°; 90°

2 -14.00 -11.00 0°; 0°; 90°

3 -7.00 -11.00 0°; 0°; 90°

4 -0.00 -11.00 0°; 0°; 90°

11 0.00 11.00 0°; 0°; -90°

12 7.00 11.00 0°; 0°; -90°

13 14.00 11.00 0°; 0°; -90°

14 19.00 11.00 0°; 0°; -90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 15x9EAv [lx] 213

Emin/EAv 0.81

CRI 80

No. floodlights 14

floodlight height [m] 10

KEY150.0 lx200.0 lx

250.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 200 0.5 20

PLAY AREA DIMENSIONSLength [m] 40Width [m] 20Grid points (length) 15Grid points (width) 9

28

REQUISITES

5IN

DO

OR

5-a-side football - 200 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 28 15/04/16 11:46

Page 28: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 32

4 5 6 7 8

1 5 7

85

132

1

2

1

3

1

4

1

5

46

1

7

68

1

9

8

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

STANDARD ELECTRICAL SCHEME -System power: 3.3kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 696 4-pole terminal block 4 mod.EN 50022 1

GW 46 205 Polyester board with window 650X515X250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 532 F Quick-assembly double rail 24M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 091 MCB 4P C40 6KA 4M 2

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 2

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 2

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 2

Standard auxiliarieS circuit

Line description Main device Lamp Line 1 km1 Line 2 km2 Auxiliaries line

Power 3.300 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 0.000 kW

Operating current Ib [A] 5.20 2.60 2.60 2.60 2.60 0.00

Rated current In [A] 32.00 40.00 25.00 40.00 25.00 6.00

Article description Control switch discon-nector 4P 32A

Surge protective device 3P+N 25kA Aux. Type

1+2 + fuse holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C40 4P+

BD 4P 63A 30mAS

Contactor 25A4NO -

230V AC/ 220V DC -2M

MT60 C40 4P+

BD 4P 63A 30mAS

Contactor 25A4NO -

230V AC/ 220V DC -2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 4.50

RCCB GW 94 532 GW 94 532

29

PB 22359 EN Cata prog Light 0316_EN.indd 29 15/04/16 11:46

Page 29: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

0 5 10 15-5-10-15Asse x (m)

05

10-5

-10

Ass

e y

(m)

-20 20

1 1

1 11 1

11

1 1

1 1

751 99

504

533

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 10

Number of floodlights 12

Number of floodlights per high mast 3

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHTGW S4 176 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -9.00 -10.50 0°; 0°; 130°

1 -8.00 -10.50 0°; 0°; 90°

1 -7.00 -10.50 0°; 0°; 55°

2 -9.00 10.50 0°; 0°; -130°

2 -8.00 10.50 0°; 0°; -90°

2 -7.00 10.50 0°; 0°; -55°

3 9.00 10.50 0°; 0°; -50°

3 8.00 10.50 0°; 0°; -90°

3 7.00 10.50 0°; 0°; -125°

4 9.00 -10.50 0°; 0°; 50°

4 8.00 -10.50 0°; 0°; 90°

4 7.00 -10.50 0°; 0°; 125°

GRID 13x7EAv [lx] 221

Emin/EAv 0.78

GR 21

CRI 80

No. floodlights 12

floodlight height [m] 10

KEY 50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx

300.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 200 0.6 50 60

PLAY AREA DIMENSIONSLength [m] 28Width [m] 15Grid points (length) 13Grid points (width) 7

30

OU

TD

OO

R

REQUISITES

Basketball - 200 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 30 15/04/16 11:46

Page 30: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

234 5 6 7

89

10 11

12

1 5 7 9 11

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

STANDARD ELECTRICAL SCHEME -System power: 2.8kW, single-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 205 Polyester board with window 650X515X250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 532 F Quick-assembly double rail 24M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 2.800 kW 0.700 kW 0.700 kW 0.700 kW 0.700 kW 0.700 kW 0.700 kW 0.700 kW 0.700 kW 0.000 kW

Operating current Ib [A] 13.60 3.40 3.40 3.40 3.40 3.40 3.40 3.40 3.40 0.00

Rated current In [A] 32.00 20.00 25.00 20.00 25.00 20.00 25.00 20.00 25.00 6.00

Article descriptionControl switch disconnector

2P 32A

Surge protec-tive device 1P+N 25kA

Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 10.3x38

230V - 3M

MCB MT60 C20 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C20 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C20 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C20 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MDC60 C6 2P

Id=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 92 048 GW D6 712 GW 92 048 GW D6 712 GW 92 048 GW D6 712 GW 92 048 GW D6 712 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94566 GW 94 566 GW 94 566 GW 94 566

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 92 048 MCB 2P C20 6KA 2M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 566 Residual current device 2P IN<63A Immun. A/0.03 2M 4

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 4

31

PB 22359 EN Cata prog Light 0316_EN.indd 31 15/04/16 11:46

Page 31: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

0 5 10 15-5-10-15Asse x (m)

05

10-5

-10

Ass

e y

(m)

-20 20

1 1

1 1

1

1

1

1

741

700

74

282

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 116

Lumen output (lm) 12,780

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 9

Number of floodlights 8

Number of floodlights per high mast 2

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 156 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -8.00 -10.00 0°; 0°; 125°

1 -7.00 -10.00 0°; 0°; 70°

4 7.00 -10.00 0°; 0°; 105°

4 8.00 -10.00 0°; 0°; 55°

2 -8.00 10.00 0°; 0°; -125°

2 -7.00 10.00 0°; 0°; -70°

4 7.00 10.00 0°; 0°; -105°

4 8.00 10.00 0°; 0°; -55°

CALCULATION RESULTS

GRID 13x7EAv [lx] 80

Emin/EAv 0.62

GR 19

CRI 80

No. floodlights 8

floodlight height [m] 9

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

KEY 30.0 lx

60.0 lx90.0 lx

120.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 75 0.5 55 20

PLAY AREA DIMENSIONSLength [m] 28Width [m] 15Grid points (length) 13Grid points (width) 7

32

OU

TD

OO

R

REQUISITES

Basketball - 75 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 32 15/04/16 11:46

Page 32: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

23

4 5

10 11

6 7 8 9 12

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

STANDARD ELECTRICAL SCHEME -System power: 1.0kW, single-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod.EN 50022 1

GW 46 204 Polyester board with window 650X405X200 1

GW 46 421 F Panel without windows 18 mod. 3

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 2

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 92 046 MCB 2P C10 6KA 2M 4

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 566 Residual current device 2P IN<63A Immun. A/0.03 2M 4

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 1.000 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.000 kW

Operating current Ib [A] 4.40 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 0.00

Rated current In [A] 32.00 10.00 25.00 10.00 25.00 10.00 25.00 10.00 25.00 6.00

Article descriptionControl switch disconnector

2P 32A

Surge protec-tive device 1P+N 25kA

Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 10.3x38

230V - 3M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 4.50

RCCB GW 94 566 GW 94 566 GW 94 566 GW 94 566

33

PB 22359 EN Cata prog Light 0316_EN.indd 33 15/04/16 11:46

Page 33: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

15-1

5

0 5 10 15-5-10-15Asse x (m)

-20 20-25 25

1 1 1

1 1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 40

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -15.00 -11.00 0°; 0°; 90°

2 -14.00 -11.00 0°; 0°; 90°

3 -13.00 -11.00 0°; 0°; 90°

4 -12.00 -11.00 0°; 0°; 90°

5 -10.00 -11.00 0°; 0°; 90°

6 -8.50 -11.00 0°; 0°; 90°

7 -6.50 -11.00 0°; 0°; 90°

8 -4.50 -11.00 0°; 0°; 90°

9 -3.00 -11.00 0°; 0°; 90°

10 -1.00 -11.00 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x7EAv [lx] 764

Emin/EAv 0.88

CRI 80

No. floodlights 40

floodlight height [m] 10

KEY 300.0 lx

400.0 lx500.0 lx600.0 l x700.0 lx800.0 lx900.0 lx

1000.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 750 0.7 60

PLAY AREA DIMENSIONSLength [m] 28Width [m] 15Grid points (length) 13Grid points (width) 7

34

REQUISITES

IND

OO

R

Basketball - 750 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 34 15/04/16 11:46

Page 34: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

1 3

1 5 7 9

11

2

78 10 11 12

4 5 6 9

STANDARD ELECTRICAL SCHEME -System power: 9.4kW, three-phase

Line description Main device Lamp Line 1 km1 Line

2 km2 Line 3 km3 Line

4 km4 Auxiliaries line

Power 9.400 kW 2.350 kW 2.350 kW 2.350 kW 2.350 kW 2.350 kW 2.350 kW 2.350 kW 2.350 kW 0.000 kW

Operating current Ib [A] 14.80 3.70 3.70 3.70 3.70 3.70 3.70 3.70 3.70 0.00

Rated current In [A] 63.00 50.00 40.00 50.00 40.00 50.00 40.00 50.00 40.00 6.00

Article descriptionControl switch disconnector

4P 63A

Surge protective device 3P+N

25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C50 4P +BD 4P 63A

30mAS

Contactor 40A 4NO -230V AC/ 220V DC -

3M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 40A 4NO -230V AC

/220V DC -3M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 40A 4NO -230V AC

/220V DC -3M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 40A 4NO -230V AC

/220V DC -3M

MDC45 C6 2PId=30mA AC

Code GW 96 176 GW D6 405 GW 96 592 GW 92 092 GW D6 724 GW 92 092 GW D6 724 GW 92 092 GW D6 724 GW 92 092 GW D6 724 GW 94 025

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 4.50

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 MOD.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 092 MCB 4P C50 6KA 4M 4

GW 94 025 RCBO C.2P C 6 4.5KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 176 Control switch disconnector 4P 63A AC22B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 724 Contactor 40A 4NO 230V 3M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

35

PB 22359 EN Cata prog Light 0316_EN.indd 35 15/04/16 11:46

Page 35: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

0 5 10 15-5-10-15Asse x (m)

-20 20-25 25

05

10-5

-10

Ass

e y

(m)

15-1

5

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

11

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 28

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -14.00 -11.00 0°; 0°; 90°

2 -13.00 -11.00 0°; 0°; 90°

3 -12.00 -11.00 0°; 0°; 90°

4 -10.00 -11.00 0°; 0°; 90°

5 -7.00 -11.00 0°; 0°; 90°

6 -4.00 -11.00 0°; 0°; 90°

7 -2.00 -11.00 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x7EAv [lx] 530

Emin/EAv 0.89

CRI 80

No. floodlights 28

floodlight height [m] 10

KEY 200.0 lx

300.0 lx400.0 lx500.0 lx600.0 lx700.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 28Width [m] 15Grid points (length) 13Grid points (width) 7

36

REQUISITES

IND

OO

R

Basketball - 500 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 36 15/04/16 11:46

Page 36: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 3

1 5 7 9

11

2

10 11 12

4 5 6 7 8 9

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 6.6kW, three-phase

Line description Main device Lamp Line 1 km1 Line

2 km2 Line 3 km3 Line

4 km4 Auxiliaries line

Power 6.600 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 0.000 kW

Operating current Ib [A] 10.40 2.60 2.60 2.60 2.60 2.60 2.60 2.60 2.60 0.00

Rated current In [A] 40.00 32.00 25.00 32.00 25.00 32.00 25.00 32.00 25.00 6.00

Article descriptionControl switch disconnector

4P 40A

Surge protective device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signal-ling lamp with

fuse holder 230V 10.3x38 - 5M

MDC45 C32 4PId=30mA A

Contactor 25A 4NO -

230V AC /220V DC -

2M

MDC45 C32 4PId=30mA A

Contactor 25A 4NO -

230V AC /220V DC -

2M

MDC45 C32 4PId=30mA A

Contactor 25A 4NO -

230V AC /220V DC -

2M

MDC45 C32 4PId=30mA A

Contactor 25A 4NO -

230V AC /220V DC -

2M

MDC45 C6 2PId=30mA AC

Code GW 96 135 GW D6 405 GW 96 592 GW 94 270 GW D6 715 GW 94 270 GW D6 715 GW 94 270 GW D6 715 GW 94 270 GW D6 715 GW 94 025

Breaking capacity Icn/Icu [kA] 4.50 4.50 4.50 4.50 4.50

RCCB GW 94 532 GW 94 532

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 MOD.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 94 025 RCBO C.2P C 6 4.5KA AC/0.03 2M 1

GW 94 270 RCBO C.4P C32 4.5KA AC/0.03 4M 4

GW 96 135 Switch disconnector 4P 40A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

37

PB 22359 EN Cata prog Light 0316_EN.indd 37 15/04/16 11:46

Page 37: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

0 5 10 15-5-10-15Asse x (m)

-20 20-25 25

05

10-5

-10

Ass

e y

(m)

15-1

5

1 1 1

1 1 1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 10

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -12.00 -11.00 0°; 0°; 90°

2 -7.00 -11.00 0°; 0°; 90°

3 0.00 -11.00 0°; 0°; 90°

8 0.00 11.00 0°; 0°; -90°

9 7.00 11.00 0°; 0°; -90°

10 12.00 11.00 0°; 0°; -90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x7EAv [lx] 202

Emin/EAv 0.78

CRI 80

No. floodlights 10

floodlight height [m] 10

KEY 50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 200 0.5 20

PLAY AREA DIMENSIONSLength [m] 28Width [m] 15Grid points (length) 13Grid points (width) 7

38

REQUISITES

IND

OO

R

Basketball - 200 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 38 15/04/16 11:47

Page 38: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

85

132

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

1

2

1

3

1

4

1

5

46

1

7

68

1

9

8

1 32

456 7 8

STANDARD ELECTRICAL SCHEME -System power: 2.4kW, single-phase

Line description Main device Lamp Line 1 km1 Line 2 km2 Auxiliaries line

Power 2.400 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 0.000 kW

Operating current Ib [A] 11.20 5.60 5.60 5.60 5.60 0.00

Rated current In [A] 32.00 32.00 40.00 32.00 40.00 6.00

Article description Control switch discon-nector 2P 32A

Surge protective device 1P+N 25kA Aux. Type

1+2 + fuse holder 22x58 - 8M

Red signalling lamp with fuse holder 230V

10.3x38 - 3M

MDC60 C32 2PId=30mA A

Contactor 40A2NO -

230V AC/ 220V DC -3M

MDC60 C32 2PId=30mA A

Contactor 40A2NO -

230V AC/ 220V DC -3M

MDC45 C6 1P+NId=300mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 330 GW D6 721 GW 94 330 GW D6 721 GW 94 015

Breaking capacity Icn/Icu [kA] 6.00 6.00 4.50

RCCB

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod. EN 50022 1

GW 46 204 Polyester board with window 650X405X200 1

GW 46 421 F Panel without windows 18 mod. 3

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 015 RCBO C.1P+N C 6 4.5KA AC/0.3 2M 1

GW 94 330 RCBO C.2P C32 6KA AC/0.03 2M 2

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 2

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 721 Contactor 40A 2NO 230V 3M 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

39

PB 22359 EN Cata prog Light 0316_EN.indd 39 15/04/16 11:47

Page 39: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

0 5 10 15-5-10-15Asse x (m)

1 1

11

1 1

1 11 1

11

1

1 1

1

751 99

504

533

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 9

Number of floodlights 16

Number of floodlights per high mast 4

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -8.00 -8.00 0°; 0°; 100°

1 -7.00 -8.00 0°; 0°; 96°

1 -6.00 -8.00 0°; 0°; 92°

1 -5.00 -8.00 0°; 0°; 67°

4 5.00 -8.00 0°; 0°; 113°

4 6.00 -8.00 0°; 0°; 88°

4 7.00 -8.00 0°; 0°; 84°

4 8.00 -8.00 0°; 0°; 80°

GRID 13x9EAv [lx] 502

Emin/EAv 0.71

GR 19

CRI 80

No. floodlights 16

floodlight height [m] 9

PROPOSED SOLUTION

KEY300.0 lx

400.0 lx500.0 lx600.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

I 500 0.7 50 60

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

40

OU

TD

OO

R

REQUISITES

Volleyball - 500 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 40 15/04/16 11:47

Page 40: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 3.8kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 3.800 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.000 kW

Operating current Ib [A] 6.00 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 0.00

Rated current In [A] 32.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 25.00 6.00

Article descriptionControl switch disconnector

4P 32A

Surge protec-tive device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling

lamp with fuse holder 230V 10.3x38 - 5M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MCB MT60 C25 4P

+ BD 4P 63A30mA A-IR

Contactor 25A4NO -

230V AC/220V DC -

2M

MDC60 C6 2P

Id=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 92 089 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 089 MCB 4P C25 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 3.5M 4

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

41

PB 22359 EN Cata prog Light 0316_EN.indd 41 15/04/16 11:47

Page 41: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

0 5 10 15-5-10-15Asse x (m)

1 1

11

1 1

1 11 1

11

1

1 1

1

741

700

74

282

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 116

Lumen output (lm) 12,780

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 9

Number of floodlights 16

Number of floodlights per high mast 4

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 156 GS

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -9.00 -8.00 0°; 0°; 100°

1 -8.00 -8.00 0°; 0°; 90°

1 -7.00 -8.00 0°; 0°; 90°

1 -6.00 -8.00 0°; 0°; 65°

4 6.00 -8.00 0°; 0°; 115°

4 7.00 -8.00 0°; 0°; 90°

4 8.00 -8.00 0°; 0°; 90°

4 9.00 -8.00 0°; 0°; 80°

GRID 13x9EAv [lx] 236

Emin/EAv 0.72

GR 19

CRI 80

No. floodlights 16

floodlight height [m] 9

KEY 200.0 lx

250.0 lx300.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 200 0.6 50 60

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

42

OU

TD

OO

R

REQUISITES

Volleyball - 200 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 42 15/04/16 11:47

Page 42: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

23

4 5 6 7

89

10 11

12

1 5 7 9 11

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 1.8kW, single-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod.EN 50022 1

GW 46 205 Polyester board with window 650X515X250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 532 F Quick-assembly double rail 24M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 1.800 kW 0.450 kW 0.450 kW 0.450 kW 0.450 kW 0.450 kW 0.450 kW 0.450 kW 0.450 kW 0.000 kW

Operating current Ib [A] 8.80 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 0.00

Rated current In [A] 32.00 16.00 25.00 16.00 25.00 16.00 25.00 16.00 25.00 6.00

Article descriptionControl switch disconnector

2P 32A

Surge protec-tive device 1P+N 25kA

Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 10.3x38

230V - 3M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MCB MT60 C16 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/220V DC -

2M

MDC60 C6 2P

Id=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 92 047 GW D6 712 GW 92 047 GW D6 712 GW 92 047 GWD6 712 GW 92 047 GW D6 712 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 566 GW 94 566 GW 94 566 GW 94 566

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 92 047 MCB 2P C16 6KA 2M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 566 Residual current device 2P IN<63A Immun. A/0.03 2M 4

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 4

43

PB 22359 EN Cata prog Light 0316_EN.indd 43 15/04/16 11:47

Page 43: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

0 5 10 15-5-10-15Asse x (m)

05

10-5

-10

Ass

e y

(m)

1 1

1 1

1

1

1

1

741

700

74

282

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 116

Lumen output (lm) 12,780

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 9

Number of floodlights 8

Number of floodlights per high mast 2

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 156 GS

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 75 0.5 55 20

CALCULATION RESULTS

GRID 13x9EAv [lx] 127

Emin/EAv 0.64

GR 18

CRI 80

No. floodlights 8

floodlight height [m] 9

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -7.00 -8.00 0°; 0°; 90°

1 -6.00 -8.00 0°; 0°; 90°

4 6.00 -8.00 0°; 0°; 90°

4 7.00 -8.00 0°; 0°; 90°

2 -7.00 8.00 0°; 0°; 90°

2 -6.00 8.00 0°; 0°; 90°

3 6.00 8.00 0°; 0°; 90°

3 7.00 8.00 0°; 0°; 90°

KEY 90.0 lx

120.0 lx150.0 lx

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

44

OU

TD

OO

R

REQUISITES

Volleyball - 75 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 44 15/04/16 11:47

Page 44: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

23

4 5

10 11

6 7 8 9 12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 1.0kW, single-phase

Standard diStribution board

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries line

Power 1.000 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.250 kW 0.000 kW

Operating current Ib [A] 4.40 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 0.00

Rated current In [A] 32.00 10.00 25.00 10.00 25.00 10.00 25.00 10.00 25.00 6.00

Article descriptionControl switch disconnector

2P 32A

Surge protec-tive device 1P+N 25kA

Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 10.3x38

230V - 3M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MCB MT60 C10 2P

+ BD 2P 63A30mA A-IR

Contactor 25A2NO -

230V AC/ 220V DC -

2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 92 046 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 4.50

RCCB GW 94 566 GW 94 566 GW 94 566 GW 94 566

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 92 046 MCB 2P C10 6KA 2M 4

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 566 Residual current device 2P IN<63A Immun. A/0.03 2M 4

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 4

DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod.EN 50022 1

GW 46 204 Polyester board with window 650X405X200 1

GW 46 421 F Panel without windows 18 mod. 3

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 2

GW 46 531 F Quick-assembly double rail 18M 1

45

PB 22359 EN Cata prog Light 0316_EN.indd 45 15/04/16 11:47

Page 45: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

15-1

5

0 5 10 15-5-10-15Asse x (m)

-20 20

1 1

1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

11

1 1

11

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -13.00 -9.00 0°; 0°; 90°

2 -11.50 -9.00 0°; 0°; 90°

3 -10.00 -9.00 0°; 0°; 90°

4 -8.00 -9.00 0°; 0°; 90°

5 -6.00 -9.00 0°; 0°; 90°

6 -4.00 -9.00 0°; 0°; 90°

7 -2.00 -9.00 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x9EAv [lx] 768

Emin/EAv 0.85

CRI 80

No. floodlights 28

floodlight height [m] 10

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 28

KEY400.0 lx500.0 lx

600.0 lx

700.0 lx

800.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 750 0.7 60

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

46

REQUISITES

IND

OO

R

Volleyball - 750 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 46 15/04/16 11:47

Page 46: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 6.6kW, three-phase

Line description Main device Lamp Line 1 km1 Line 2 km2 Line 3 km3 Line 4 km4 Auxiliaries line

Power 6.600 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 0.000 kW

Operating current Ib [A] 10.40 2.60 2.60 2.60 2.60 2.60 2.60 2.60 2.60 0.00

Rated current In [A] 32.00 32.00 25.00 32.00 25.00 32.00 25.00 32.00 25.00 6.00

Article descriptionControl switch disconnector

4P 32A

Surge protective device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C32 4P+ BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor25A 4NO -230V AC

/220V DC -2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -230V AC

/220V DC -2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor25A 4NO -230V AC

/220V DC -2M

MDC60 C6 2PId=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 MOD.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3GW 92 090 MCB 4P C32 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

47

PB 22359 EN Cata prog Light 0316_EN.indd 47 15/04/16 11:47

Page 47: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

15-1

5

0 5 10 15-5-10-15Asse x (m)

-20 20

1 1 1

1 1 1

1

1

1

1

1

1

1

1

1

1

1

1 1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 20

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -13.00 -9.00 0°; 0°; 90°

2 -11.00 -9.00 0°; 0°; 90°

3 -8.00 -9.00 0°; 0°; 90°

4 -5.00 -9.00 0°; 0°; 90°

5 -2.00 -9.00 0°; 0°; 90°

6 2.00 -9.00 0°; 0°; 90°

7 5.00 -9.00 0°; 0°; 90°

8 8.00 -9.00 0°; 0°; 90°

9 11.00 -9.00 0°; 0°; 90°

10 13.00 -9.00 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x9EAv [lx] 544

Emin/EAv 0.84

CRI 80

No. floodlights 20

floodlight height [m] 10

KEY 300.0 lx

350.0 lx400.0 lx450.0 lx500.0 lx550.0 lx600.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

48

REQUISITES

IND

OO

R

Volleyball - 500 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 48 15/04/16 11:48

Page 48: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 4.8kW, three-phase

Line description Main device Lamp Line 1 km1 Line 2 km2 Line 3 km3 Line 4 km4 Auxiliaries line

Power 4.800 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 1.200 kW 0.000 kW

Operating current Ib [A] 7.60 1.90 1.90 1.90 1.90 1.90 1.90 1.90 1.90 0.00

Rated current In [A] 32.00 32.00 25.00 32.00 25.00 32.00 25.00 32.00 25.00 6.00

Article descriptionControl switch disconnector

4P 32A

Surge protective device 3P+N

25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -230V AC

/220V DC -2M

MT60 C32 4P + BD 4P 25A

30mAS

Contactor 25A 4NO -230V AC

/220V DC -2M

MT60 C32 4P+ BD 4P 63A

30mAS

Contactor 25A 4NO -230V AC

/220V DC -2M

MT60 C32 4P+ BD 4P 25A

30mAS

Contactor25A 4NO -230V AC

/220V DC -2M

MDC60 C6 2PId=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 090 GW D6 715 GW 92090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 522 GW 94 532 GW 94 522

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod. EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 518 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3GW 92 090 MCB 4P C32 6KA 4M 4GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1GW 94 522 Residual current device 4P IN<25A INSTANT. A/0.03 3.5M 2GW 94 532 Residual current device 4P IN<63A INSTANT. A/0.03 3.5M 2GW 96 134 Switch disconnector 4P 32A AC23B 1GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1GW 96 592 Triple red indicator lamp 230V 1M 1GW D6 644 Latching relay 1NO 16A 230V 4GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

49

PB 22359 EN Cata prog Light 0316_EN.indd 49 15/04/16 11:48

Page 49: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

15-1

5

0 5 10 15-5-10-15Asse x (m)

-20 20

1 1 1 1

1 1 1 1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 8

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -10.00 -9.00 0°; 0°; 90°

2 -4.50 -9.00 0°; 0°; 90°

3 4.50 -9.00 0°; 0°; 90°

4 10.00 -9.00 0°; 0°; 90°

5 -10.00 9.00 0°; 0°; -90°

6 -4.50 9.00 0°; 0°; -90°

7 4.50 9.00 0°; 0°; -90°

8 10.00 9.00 0°; 0°; -90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 13x9EAv [lx] 239

Emin/EAv 0.79

CRI 80

No. floodlights 8

floodlight height [m] 10

KEY100.0 lx150.0 lx200.0 lx

250.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 200 0.5 20

PLAY AREA DIMENSIONSLength [m] 24Width [m] 15Grid points (length) 13Grid points (width) 9

50

REQUISITES

IND

OO

R

Volleyball - 200 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 50 15/04/16 11:48

Page 50: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

85

132

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

1 32

4 5 6 7 8

1

2

1

3

1

4

1

5

46

1

7

68

1

9

8

STANDARD ELECTRICAL SCHEME -System power: 1.9kW, single-phase

Line description Main device Lamp Line 1 km1 Line 2 km2 Auxiliaries line

Power 1.900 kW 0.950 kW 0.950 kW 0.950 kW 0.950 kW 0.000 kW

Operating current Ib [A] 9.0 4.50 4.50 4.50 4.50 0.00

Rated current In [A] 32.00 25.00 40.00 25.00 40.00 6.00

Article description Control switch discon-nector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 230V

10.3x38 - 3M

MDC60 C25 2PId=30mA A

Contactor 40A2NO -

230V AC/ 220V DC -3M

MDC60 C25 2PId=30mA A

Contactor 40A2NO -

230V AC/ 220V DC -3M

MDC45 C6 1P+NId=30mA AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 329 GW D6 721 GW 94 329 GW D6 721 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 4.50

RCCB

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 mod. EN 50022 1

GW 46 204 Polyester board with window 650X405X200 1

GW 46 421 F Panel without windows 18 mod. 3

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 329 RCBO C.2P C25 6KA AC/0.03 2M 2

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 2

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 721 Contactor 40A 2NO 230V 3M 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

51

PB 22359 EN Cata prog Light 0316_EN.indd 51 15/04/16 11:48

Page 51: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

0 5 10 15 20-5-10-15-20Asse x (m)

05

1015

20-5

-10

-15

-20

Ass

e y

(m)

1

11

1

1 1

1 11 1

1 1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

GRID 15x7EAv [lx] 308

Emin/EAv 0.73

GR 26

CRI 80

No. floodlights 12

floodlight height [m] 14

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -11.00 -20.00 0°; 0°; 140°

1 -10.00 -20.00 0°; 0°; 125°

1 -9.00 -20.00 0°; 0°; 50°

2 -11.00 20.00 0°; 0°; -140°

2 -10.00 20.00 0°; 0°; -125°

2 -9.00 20.00 0°; 0°; -50°

3 11.00 20.00 0°; 0°; -40°

3 10.00 20.00 0°; 0°; -55°

3 9.00 20.00 0°; 0°; -130°

4 11.00 -20.00 0°; 0°; 40°

4 10.00 -20.00 0°; 0°; 55°

4 9.00 -20.00 0°; 0°; 130°

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 14

Number of floodlights 12

Number of floodlights per high mast 3

ASYMMETRICAL STADIUM FLOODLIGHT 1000W GW 84 667

KEY200.0 lx250.0 lx

300.0 lx

350.0 lx

PLAY AREA DIMENSIONSLength [m] 36Width [m] 36Grid points (length) 15Grid points (width) 7

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 300 0.7 50 60

52

OU

TD

OO

R

REQUISITES

Tennis - 300 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 52 15/04/16 11:48

Page 52: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

3

4 5

6

7

8

9

10

11

12

13IdIdIdIdId

AUX

STANDARD ELECTRICAL SCHEME -System power: 12kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 12.000 kW 0.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 0.000 kW

Operating current Ib [A] 19.27 0.00 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 0.00

Rated current In [A] 32.00 50.00 10.00 24.00 10.00 24.00 10.00 24.00 10.00 24.00 6.00

Article description MT100 D32 4P

Disconnectable fuse holder

3P+N 22x58

690V 50A

Surge protec-tive device 3P+N 25kAType 1+2

Triple red signalling

lamp with fuse holder 230V

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4NO

230V AC/DC 24A - 2M

MDC60 C6 2PId=30mA AC

Code GW 92 790 GW 96 314 GW D6 405 GW 96 592 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW 96 712 GW 94 125

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 790 MCB 4P D32 10KA 4M 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 486 MCB 4P D10 6KA 4M 4

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 4

GW D6 715 Contactor 230V 4NO 24A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800x585x300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 515MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 8M 1

53

PB 22359 EN Cata prog Light 0316_EN.indd 53 15/04/16 11:48

Page 53: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

20-5

-10

-15

-20

Ass

e y

(m)

0 5 10 15 20-5-10-15-20Asse x (m)

1

11

1

1 1

1 11 1

1 1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

GRID 15x7EAv [lx] 242

Emin/EAv 0.66

GR 27

CRI 80

No. floodlights 8

floodlight height [m] 13

FLOODLIGHT POSITIONINGLighting

towerPosition of devices

XPosition of devices

Y Device rotation X°; Y°; Z°

1 -12.00 -20.00 0°; 0°; 120°

1 -11.00 -20.00 0°; 0°; 55°

2 -12.00 20.00 0°; 0°; -120°

2 -11.00 20.00 0°; 0°; -55°

3 12.00 20.00 0°; 0°; -60°

3 11.00 20.00 0°; 0°; -125°

4 12.00 -20.00 0°; 0°; 60°

4 11.00 -20.00 0°; 0°; 125°

TECHNICAL DATA OF THE LAMP Maintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 13

Number of floodlights 8

Number of floodlights per high mast 2

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT 1000W GW 84 667

KEY150.0 lx200.0 lx

250.0 lx

300.0 lx

PLAY AREA DIMENSIONSLength [m] 36Width [m] 36Grid points (length) 15Grid points (width) 7

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 200 0.6 55 20

54

OU

TD

OO

R

REQUISITES

Tennis - 200 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 54 15/04/16 11:48

Page 54: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1

R

2

3

4 5

6

7

8

9

10

11

12

13

Id

AUX

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

STANDARD ELECTRICAL SCHEME -System power: 8kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 8.000 kW 0.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 0.000 kW

Operating current Ib [A] 19.32 0.00 9.66 9.66 9.66 9.66 9.66 9.66 9.66 9.66 0.00

Rated current In [A] 20.00 20.00 16.00 20.00 16.00 20.00 16.00 20.00 16.00 20.00 6.00

Article description

MCB MT100 D20 4P +

BD 4P 63A30mA A-IR

Disconnect-able fuse holder

3P+N22x58 690V

100A

Surge protec-tive device 3P+N 25kAType 1+2

Triple red signalling

lamp with fuse holder 230V

MT60 D16 2P

Contactor 2NO

230V AC - 20A 1M

MT60 D16 2P

Contactor 2NO

230V AC - 20A 1M

MT60 D16 2P

Contactor 2NO

230V AC - 20A 1M

MT60 D16 2P

Contactor 2NO

230V AC - 20A 1M

MTC60 C6 1P+N

Code GW 92 788 GW 96 314 GW D6 405 GW 96 592 GW 92 447 GWD6703 GW 92 447 GWD6703 GW 92 447 GWD6703 GW 92 447 GWD6703 GW 90 225

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 + GW 90 893

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 205 Polyester board with window 650x515x250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM 1

GW 46 437 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 532 F Double rail 24M 1

GW 44 696 4-pole terminal block 4M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 788 MCB 4P D20 10KA 4M 1

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 1

GW 90 893 Adjustable reset RM TOP 4P 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 447 MCB 2P D16 6KA 2M 4

GW D6 703 Contactor 230V 2NO 20A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 90 225 Compact MCB 1P+N C 6 6KA 1M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

55

PB 22359 EN Cata prog Light 0316_EN.indd 55 15/04/16 11:48

Page 55: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 11 1

1 11 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 36

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

Lighting project for indoor sports centre.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -18.00 -9.00 0°; 0°; 90°

2 -17.00 -9.00 0°; 0°; 90°

3 -16.00 -9.00 0°; 0°; 90°

4 -13.00 -9.00 0°; 0°; 90°

5 -10.00 -9.00 0°; 0°; 90°

6 -7.50 -9.00 0°; 0°; 90°

7 -5.00 -9.00 0°; 0°; 90°

8 -3.00 -9.00 0°; 0°; 90°

9 -1.00 -9.00 0°; 0°; 90°

GRID 15x7EAv [lx] 773

Emin/EAv 0.80

CRI 80

No. floodlights 36

floodlight height [m] 10

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

KEY500.0 lx600.0 lx700.0 lx

800.0 lx

900.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 750 0.7 60

PLAY AREA DIMENSIONSLength [m] 36Width [m] 18Grid points (length) 15Grid points (width) 7

56

REQUISITES

IND

OO

R

Tennis - 750 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 56 15/04/16 11:48

Page 56: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11

12

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 8.4kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3GW 92 091 MCB 4P C40 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp Line 1 km1 Line 2 km2 Line 3 km3 Line 4 km4 Auxiliaries line

Power 8.400 kW 2.100 kW 2.100 kW 2.100 kW 2.100 kW 2.100 kW 2.100 kW 2.100 kW 2.100 kW 0.000 kW

Operating current Ib [A] 13.20 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 0.00

Rated current In [A] 32.00 40.00 25.00 40.00 25.00 40.00 25.00 40.00 25.00 6.00

Article descriptionControl

switch discon-nector 4P 32A

Surge protec-tive device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling

lamp with fuse holder 230V 10.3x38 - 5M

MT60 C40 4P+

BD 4P 63A30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C40 4P+

BD 4P 63A30mA A

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C404P+

BD 4P 63A30mA A

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C40 4P+

BD 4P 63A30mA A

Contactor 25A4NO -

230V AC/220V DC -

2M

MDC60 C6 2P

Id=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

57

PB 22359 EN Cata prog Light 0316_EN.indd 57 15/04/16 11:48

Page 57: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 1 1 1 1 1

1 1 1 1 1 11

1

1

1

1

1

1

1

1

1 1

1

751 99

504

533

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 24

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

Lighting project for indoor sports centre.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -17.00 -9.00 0°; 0°; 90°

2 -15.00 -9.00 0°; 0°; 90°

3 -11.50 -9.00 0°; 0°; 90°

4 -8.50 -9.00 0°; 0°; 90°

5 -5.50 -9.00 0°; 0°; 90°

6 -2.00 -9.00 0°; 0°; 90°

GRID 15x7EAv [lx] 526

Emin/EAv 0.75

CRI 80

No. floodlights 24

floodlight height [m] 10

KEY300.0 lx400.0 lx

500.0 lx

600.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 36Width [m] 18Grid points (length) 15Grid points (width) 7

58

REQUISITES

IND

OO

R

Tennis - 500 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 58 15/04/16 11:49

Page 58: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 5.6kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 4

GW 46 423 F Panel without windows 28 mod. 1

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 galvanised steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 090 MCB 4P C32 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp Line 1 km1 Line 2 km2 Line 3 km3 Line 4 km4 Auxiliaries line

Power 5.600 kW 1.400 kW 1.400 kW 1.400 kW 1.400 kW 1.400 kW 1.400 kW 1.400 kW 1.400 kW 0.000 kW

Operating current Ib [A] 8.80 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 0.00

Rated current In [A] 32.00 32.00 25.00 32.00 25.00 32.00 25.00 32.00 25.00 6.00

Article descriptionControl switch disconnector

4P 32A

Surge protec-tive device

3P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signalling

lamp with fuse holder 230V 10.3x38 - 5M

MT60 C32 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/ 220V DC -

2M

MT60 C32 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C32 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C32 4P+

BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/220V DC -

2M

MDC60 C6 2P

Id=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

59

PB 22359 EN Cata prog Light 0316_EN.indd 59 15/04/16 11:49

Page 59: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

05

1015

-5-1

0-1

5

Ass

e y

(m)

1 1 1 1 1

1 1 1 1 1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

TECHNICAL DATA OF THE FLOODLIGHTS Floodlight assembly height (m) 10

Number of floodlights 14

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -15.50 -9.00 0°; 0°; 90°

2 -13.00 -9.00 0°; 0°; 90°

3 -5.00 -9.00 0°; 0°; 90°

4 0.00 -9.00 0°; 0°; 90°

11 0.00 9.00 0°; 0°; -90°

12 5.00 9.00 0°; 0°; -90°

13 13.00 9.00 0°; 0°; -90°

14 15.50 9.00 0°; 0°; -90°

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

GRID 15x7EAv [lx] 302

Emin/EAv 0.79

CRI 80

No. floodlights 14

floodlight height [m] 10

Lighting project for indoor sports centre.

KEY200.0 lx250.0 lx

300.0 lx

350.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 300 0.5 20

PLAY AREA DIMENSIONSLength [m] 36Width [m] 18Grid points (length) 15Grid points (width) 7

60

REQUISITES

IND

OO

R

Tennis - 300 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 60 15/04/16 11:49

Page 60: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 32

1 5 74 5 7 86

85

132

1

2

1

3

1

4

1

5

46

1

7

68

1

9

8

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

STANDARD ELECTRICAL SCHEME -System power: 3.3kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 696 4-pole terminal block 4 mod.EN 50022 1

GW 46 205 Polyester board with window 650X515X250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 532 F Quick-assembly double rail 24M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 091 MCB 4P C40 6KA 4M 2

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 2

GW 96 134 Switch disconnector 4P 32A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 2

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp Line 1 km1 Line 2 km2 Auxiliaries line

Power 3.300 kW 1.650 kW 1.650 kW 1.650 kW 1.650 kW 0.000 kW

Operating current Ib [A] 5.20 2.60 2.60 2.60 2.60 0.00

Rated current In [A] 32.00 40.00 25.00 40.00 25.00 6.00

Article description Control switch disconnector 4P 32A

Surge protective device 3P+N 25kA Aux. Type

1+2 + fuse holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C40 4P+

BD 4P 63A 30mAS

Contactor 25A4NO -

230V AC/220V DC -

2M

MT60 C40 4P+

BD 4P 63A 30mAS

Contactor 25A4NO -

230V AC/ 220V DC -

2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 134 GW D6 405 GW 96 592 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 4.50

RCCB GW 94 532 GW 94 532

61

PB 22359 EN Cata prog Light 0316_EN.indd 61 15/04/16 11:49

Page 61: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

-30-35 30 35

05

1015

-5-1

0-1

5

Ass

e y

(m)

-20

20

1 1

1 11

1 1

11

1 1

1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 14

Number of floodlights 12

Number of floodlights per high mast 3

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

ASYMMETRICAL STADIUM FLOODLIGHT 1000W GW 84 667

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -16.50 -15.00 0°; 0°; 140°

1 -15.50 -15.00 0°; 0°; 90°

1 -14.50 -15.00 0°; 0°; 45°

2 -16.50 15.00 0°; 0°; -140°

2 -15.50 15.00 0°; 0°; -90°

2 -14.50 15.00 0°; 0°; -45°

3 16.50 15.00 0°; 0°; -40°

3 15.50 15.00 0°; 0°; -90°

3 14.50 15.00 0°; 0°; -135°

4 16.50 -15.00 0°; 0°; 40°

4 15.50 -15.00 0°; 0°; 90°

4 14.50 -15.00 0°; 0°; 135°

GRID 17x7EAv [lx] 380

Emin/EAv 0.71

GR -

CRI 80

No. floodlights 12

floodlight height [m] 14

KEY 50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx300.0 lx350.0 lx400.0 lx450.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

II 300 0.7 - 60

PLAY AREA DIMENSIONSLength [m] 50Width [m] 21Grid points (length) 17Grid points (width) 7

62

OU

TD

OO

R

REQUISITES

Swimming - 300 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 62 15/04/16 11:49

Page 62: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

3

4 5

6

7

8

9

10

11

12

13IdIdIdIdId

AUX

STANDARD ELECTRICAL SCHEME -System power: 12kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 12.000 kW 0.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 3.000 kW 0.000 kW

Operating current Ib [A] 19.27 0.00 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 0.00

Rated current In [A] 32.00 50.00 10.00 24.00 10.00 24.00 10.00 24.00 10.00 24.00 6.00

Article description MT100 D32 4P

Disconnectable fuse holder

3P+N22x58 690V 50A

Surge protec-tive device 3P+N 25kAType 1+2

Triple red signalling

lamp with fuse holder 230V

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MDC60 C6 2PId=30mA AC

Code GW 92 790 GW 96 314 GW D6 405 GW 96 592 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 94 125

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 515MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 8M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 790 MCB 4P D32 10KA 4M 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 486 MCB 4P D10 6KA 4M 4

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 4

GW D6 715 Contactor 230V 4NO 24A 4

GWD6644 Latching relay 1NO 16A 230V 4

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

63

PB 22359 EN Cata prog Light 0316_EN.indd 63 15/04/16 11:49

Page 63: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

-25 250 5 10 15 20-5-10-15-20Asse x (m)

-30-35 30 35

05

1015

-5-1

0-1

5

Ass

e y

(m)

-20

20

1 1

1 11

1 1

1

430

660

770

630170170

ø14 ø14

PROPOSED SOLUTION

CALCULATION RESULTS

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Stadium

Optic Asymmetrical

Lamp MHN-LA 1000W/842

Lamp flux (lm) 100,000

TECHNICAL DATA OF THE HIGH MASTSNumber of high masts 4

High mast height (m. above ground) 14

Number of floodlights 8

Number of floodlights per high mast 2

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

VALUES REQUIRED

Class EAv [lx] Emin/EAv GR Colour rendering index [CRI]

III 200 0.5 - 20

ASYMMETRICAL STADIUM FLOODLIGHT 1000W - GW 84 667

FLOODLIGHT POSITIONINGLighting

towerPosition of devices in

XPosition of devices in

Y Device rotation X°; Y°; Z°

1 -16.00 -15.00 0°; 0°; 125°

1 -15.00 -15.00 0°; 0°; 45°

2 -16.00 15.00 0°; 0°; -125°

2 -15.00 15.00 0°; 0°; -45°

3 16.00 15.00 0°; 0°; -55°

3 15.00 15.00 0°; 0°; -135°

4 16.00 -15.00 0°; 0°; 55°

4 15.00 -15.00 0°; 0°; 135°

GRID 17x7EAv [lx] 252

Emin/EAv 0.71

GR -

CRI 80

No. floodlights 8

floodlight height [m] 14

KEY50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx

300.0 lx

350.0 lx

PLAY AREA DIMENSIONSLength [m] 50Width [m] 21Grid points (length) 17Grid points (width) 7

64

OU

TD

OO

R

REQUISITES

Swimming - 200 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 64 15/04/16 11:49

Page 64: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

132

171

1 3

1 5 7 9

11

2

4 5 6 7

8 9

101112

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

3

4 5

6

7

8

9

10

11

12

13IdIdIdIdId

AUX

STANDARD ELECTRICAL SCHEME -System power: 8kW, three-phase

Line description Main device Surge protec-tive device Lamp High mast 1 km1 High mast 2 km2 High mast 3 km3 High mast 4 km4 Auxiliaries

circuit

Power 8.000 kW 0.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 2.000 kW 0.000 kW

Operating current Ib [A] 12.85 0.00 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 0.00

Rated current In [A] 20.00 20.00 10.00 24.00 10.00 24.00 10.00 24.00 10.00 24.00 6.00

Article description MT100 D20 4P

Disconnectable fuse holder 3P+N 22x58 690V 100A

Surge protec-tive device 3P+N 25kAType 1+2

Triple red signalling

lamp with fuse holder 230V

MCB MT60 D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MCB MT60D10 4P +

BD 4P 63A30mA A-IR

Contactor 4 NO

230V AC/DC 24A - 2M

MDC60 C6 2PId=30mA AC

Code GW 92 788 GW 96 314 GW D6 405 GW 96 592 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 92 486 GW D6 715 GW 94 125

Breaking capacity [kA] 10.00 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 586 GW 94 586 GW 94 586 GW 94 586

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows - 28 mod. 4

GW 46 428 F Blank panel 1M. 515MM 1

GW 46 438 F Pair of uprights 1

GW 46 446 Set of 4 galvanised fixing brackets 1

GW 46 533 F Double rail 28M 1

GW 44 698 4-pole terminal block 8M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 92 788 MCB 4P D20 10KA 4M 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 400V 100A 1

GW D6 405 Surge protective device 3P+N 25KA TYPE 1+2 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 92 486 MCB 4P D10 6KA 4M 4

GW 94 586 Residual current device 4P IN<63A Immun. A/0.03 4

GW D6 715 Contactor 230V 4NO 24A 4

GW D6 644 Latching relay 1NO 16A 230V 4

GW 94 125 RCBO 2P C6 6KA AC/0.03 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

65

PB 22359 EN Cata prog Light 0316_EN.indd 65 15/04/16 11:49

Page 65: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

-5-1

0-1

5

Ass

e y

(m)

-25 250 5 10 15 20-5-10-15-20Asse x (m)

30-30

1 1

1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 38

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -25.50 -11.70 0°; 0°; 90°

2 -24.00 -11.70 0°; 0°; 90°

3 -22.00 -11.70 0°; 0°; 90°

4 -20.00 -11.70 0°; 0°; 90°

5 -17.00 -11.70 0°; 0°; 90°

6 -13.00 -11.70 0°; 0°; 90°

7 -9.00 -11.70 0°; 0°; 90°

8 -5.50 -11.70 0°; 0°; 90°

9 -3.00 -11.70 0°; 0°; 90°

10 0.00 -11.70 0°; 0°; 90°

CALCULATION RESULTS

GRID 17x7EAv [lx] 520

Emin/EAv 0.83

CRI 80

No. floodlights 38

floodlight height [m] 10

Lighting project for indoor sports centre.

KEY350.0 lx400.0 lx450.0 lx500.0 lx550.0 lx

600.0 lx

650.0 lx

700.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 50Width [m] 21Grid points (length) 17Grid points (width) 7

66

REQUISITES

IND

OO

R

Swimming - 500 lx - High-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 66 15/04/16 11:49

Page 66: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 8.9kW, three-phase

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 MOD.EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 041 Illuminated green push-button 4

GW 74 201 1 NO contact 10A 250V 4

GW 74 211 Lamp-holder - BA95 coupling 4

GW 74 218 Lamp - BA95 coupling 4

GW 74 221 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 092 MCB 4P C50 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 176 Control switch disconnector 4P 63A AC22B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW 96 623 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Line description Main device Lamp Line1 km1 Line

2 km2 Line3 km3 Line

4 km4 Auxiliaries line

Power 8.900 kW 2.350 kW 2.350 kW 2.100 kW 2.100 kW 2.350 kW 2.350 kW 2.100 kW 2.100 kW 0.000 kW

Operating current Ib [A] 14.0 3.70 3.70 3.30 3.30 3.70 3.70 3.30 3.30 0.00

Rated current In [A] 40.00 50.00 25.00 50.00 25.00 50.00 25.00 50.00 25.00 6.00

Article descriptionControl switch disconnector

4P 40A

Surge protec-tive device 3P+N 25kA

Aux. Type 1+2 + fuse holder 22x58 - 16M

Triple red signal-ling lamp with

fuse holder 230V 10.3x38 - 5M

MT60 C50 4P + BD 4P 63A

30mA S

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MT60 C50 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MDC60 C6 2PId=30mA AC

Code GW 96 135 GW D6 405 GW 96 592 GW 92 092 GW D6 715 GW 92 092 GW D6 715 GW 92 092 GW D6 715 GW 92 092 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

67

PB 22359 EN Cata prog Light 0316_EN.indd 67 15/04/16 11:49

Page 67: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

-5-1

0-1

5

Ass

e y

(m)

-25 250 5 10 15 20-5-10-15-20Asse x (m)

30-30

1 1 1 1

1 1 1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 22

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -23.50 -12.00 0°; 0°; 90°

2 -21.00 -12.00 0°; 0°; 90°

3 -18.00 -12.00 0°; 0°; 90°

4 -11.50 -12.00 0°; 0°; 90°

5 -5.00 -12.00 0°; 0°; 90°

6 0.00 -12.00 0°; 0°; 90°

7 5.00 -12.00 0°; 0°; 90°

8 11.50 -12.00 0°; 0°; 90°

9 18.00 -12.00 0°; 0°; 90°

10 21.00 -12.00 0°; 0°; 90°

11 23.50 -12.00 0°; 0°; 90°

CALCULATION RESULTS

GRID 17x7EAv [lx] 301

Emin/EAv 0.81

CRI 80

No. floodlights 22

floodlight height [m] 10

Lighting project for indoor sports centre.

KEY200.0 lx250.0 lx300.0 lx350.0 lx400.0 lx

450.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 300 0.7 60

PLAY AREA DIMENSIONSLength [m] 50Width [m] 21Grid points (length) 17Grid points (width) 7

68

REQUISITES

IND

OO

R

Swimming - 300 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 68 15/04/16 11:49

Page 68: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 3

1 5 7 9

11

2

4 5 6 7

8 9

10 11 12

132

171

NEUTRO

FASE

P3

Kpp3

Kpp3

Km3

Kpp4

Kpp4

P4P2

Kpp2

Kpp2

Km2Km1

Kpp1

Kpp1

P1

Km4

1

2

1

3

1

4

1

5

46

1

7

68

1

9

810

1

11

1012

1

13

12

STANDARD ELECTRICAL SCHEME -System power: 5.2kW, three-phase

Line description Main device Lamp Line 1 km1 Line

2 km2 Line 3 km3 Line

4 km4 Auxiliaries line

Power 5.200 kW 1.400 kW 1.400 kW 1.200 kW 1.200 kW 1.400 kW 1.400 kW 1.200 kW 1.200 kW 0.000 kW

Operating current Ib [A] 8.20 2.20 2.20 1.90 1.90 2.20 2.20 1.90 1.90 0.00

Rated current In [A] 40.00 32.00 25.00 32.00 25.00 32.00 25.00 32.00 25.00 6.00

Article descriptionControl switch disconnector

4P 40A

Surge protective device 3P+N

25kA Aux. Type 1+2 + fuse

holder 22x58 - 16M

Triple red signal-ling lamp with

fuse holder 230V 10.3x38 - 5M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC/ 220V DC - 2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC/ 220V DC - 2M

MT60 C32 4P + BD 4P 63A

30mAS

Contactor 25A 4NO -

230V AC / 220V DC - 2M

MDC60 C6 2PId=30mA AC

Code GW 96 135 GW D6 405 GW 96 592 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 92 090 GW D6 715 GW 94 125

Breaking capacity Icn/Icu [kA] 6.00 6.00 6.00 6.00 6.00

RCCB GW 94 532 GW 94 532 GW 94 532 GW 94 532

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 698 4-pole terminal block 8 mod. EN 50022 1

GW 46 206 Polyester board with window 800X585X300 1

GW 46 423 F Panel without windows 28 mod. 4

GW 46 428 F Blank panel 1M. 585MM GR.RAL7035 1

GW 46 438 F Pair of uprights for boards 800X585X300 1

GW 46 446 Set of 4 steel brackets for fixing surface-mounting boards 1

GW 46 533 F Quick-assembly double rail 28M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 104 6-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 4

GW 74 501 1 NO contact 10A 250V 4

GW 74 511 Lamp-holder - BA95 coupling 4

GW 74 518 Lamp - BA95 coupling 4

GW 74 521 Black cap 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 090 MCB 4P C32 6KA 4M 4

GW 94 125 RCBO C.2P C 6 6KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 4

GW 96 135 Switch disconnector 4P 40A AC23B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 4

GW D6 405 Surge protective device 3P+N 25KA AUX TYPE 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 4

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

69

PB 22359 EN Cata prog Light 0316_EN.indd 69 15/04/16 11:49

Page 69: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

1015

-5-1

0-1

5

Ass

e y

(m)

-25 250 5 10 15 20-5-10-15-20Asse x (m)

30-30

1 1 1 1 1

1 1 1 1 1

1

1

1

1

1

1

751 99

504

533

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Floodlight Smart [4] 2.0

Optic Asymmetrical

Power system (W) 232

Lumen output (lm) 25,560

ASYMMETRICAL SMART [4] 2.0 FLOODLIGHT GW S4 176 GS

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

FLOODLIGHT POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -24.00 -11.50 0°; 0°; 90°

2 -20.00 -11.50 0°; 0°; 90°

3 -12.00 -11.50 0°; 0°; 90°

4 -4.00 -11.50 0°; 0°; 90°

13 4.00 11.50 0°; 0°; -90°

14 12.00 11.50 0°; 0°; -90°

15 20.00 11.50 0°; 0°; -90°

16 24.00 11.50 0°; 0°; -90°

CALCULATION RESULTS

GRID 17x7EAv [lx] 220

Emin/EAv 0.80

CRI 80

No. floodlights 16

floodlight height [m] 10

TECHNICAL DATA OF THE FLOODLIGHTSFloodlight assembly height (m) 10

Number of floodlights 16

Lighting project for indoor sports centre.

KEY150.0 lx200.0 lx250.0 lx

300.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 200 0.5 20

PLAY AREA DIMENSIONSLength [m] 50Width [m] 21Grid points (length) 17Grid points (width) 7

70

REQUISITES

IND

OO

R

Swimming - 200 lx - Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 70 15/04/16 11:49

Page 70: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 32

4 5 6 7 8

1 5 7

85

132

1

2

1

3

1

4

1

5

46

1

7

68

1

9

8

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

STANDARD ELECTRICAL SCHEME -System power: 3.8kW, three-phase

Line description Main device Lamp Line 1 km1 Line 2 km2 Auxiliaries line

Power 3.800 kW 1.900 kW 1.900 kW 1.900 kW 1.900 kW 0.000 kW

Operating current Ib [A] 6.00 3.00 3.00 3.00 3.00 0.00

Rated current In [A] 63.00 40.00 25.00 40.00 25.00 6.00

Article description Control switch discon-nector 4P 63A

Surge protective device 3P+N 25kA Aux. Type

1+2 + fuse holder 22x58 - 16M

Triple red signalling lamp with fuse holder

230V 10.3x38 - 5M

MT60 C40 4P +BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/ 220V DC -2M

MT60 C40 4P +BD 4P 63A 30mA

S

Contactor 25A4NO -

230V AC/ 220V DC -2M

MDC45 C6 1P+NId=30mA AC

Code GW 96 176 GW D6 405 GW 96 592 GW 92 091 GW D6 715 GW 92 091 GW D6 715 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 6.00 4.50

RCCB GW 94 532 GW 94 532

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 696 4-pole terminal block 4 mod. EN 50022 1

GW 46 205 Polyester board with window 650X515X250 1

GW 46 422 F Panel without windows 24 mod. 3

GW 46 427 F Blank panel 1M. 515MM GR.RAL7035 1

GW 46 437 F Pair of uprights for boards 650X405X200 1

GW 46 532F Quick-assembly double rail 24M 1

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 3

GW 92 091 MCB 4P C40 6KA 4M 2

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 532 Residual current device 4P IN<63A Instant. A/0.03 3.5M 2

GW 96 176 Control switch disconnector 4P 63A AC22B 1

GW 96 312 Disconnectable fuse holder 3P+N 10.3X38 400V 32A 1

GW 96 314 Disconnectable fuse holder 3P+N 22X58 690V 1

GW 96 592 Triple red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 2

GW D6 405 Surge protective device 3P+N 25KA aux type 1+2 1

GW D6 715 Contactor 25A 4NO 230V 2M 2

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

71

PB 22359 EN Cata prog Light 0316_EN.indd 71 15/04/16 11:49

Page 71: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

-5

Ass

e y

(m)

0 5-5Asse x (m)

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 2 0 07

61 1 0

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Ceiling-mounting luminaire SMART [3]

Optic Opal

Power system (W) 51

Lumen output (lm) 5977

Play area dimensions

LED WATERTIGHT LUMINAIRE SMART[3] 1600MM GW S3 258 P

TECHNICAL DATA OF THE WATERTIGHT LUMINAIRESFloodlight assembly height (m) 4.5

Number of floodlights 15

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

WATERTIGHT LUMINAIRES POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -4.00 -2.20 0°; 0°; 90°2 -4.00 0.00 0°; 0°; 90°3 -4.00 2.20 0°; 0°; 90°4 -2.00 -2.20 0°; 0°; 90°5 -2.00 0.00 0°; 0°; 90°6 -2.00 2.20 0°; 0°; 90°7 0.00 -2.20 0°; 0°; 90°8 0.00 0.00 0°; 0°; 90°9 0.00 2.20 0°; 0°; 90°

10 2.00 -2.20 0°; 0°; 90°11 2.00 0.00 0°; 0°; 90°12 2.00 2.20 0°; 0°; 90°13 4.00 -2.20 0°; 0°; 90°14 4.00 0.00 0°; 0°; 90°15 4.00 2.20 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 9x5EAv [lx] 772

Emin/EAv 0.80

CRI 80

No. of luminaires 15

luminaire h. [m] 4.5

KEY700.0 lx800.0 lx

900.0 lx

1000.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 750 0.7 60

PLAY AREA DIMENSIONSLength [m] 9.75Width [m] 6.40Grid points (length) 9Grid points (width) 5

72

REQUISITES

IND

OO

R

Squash - 750 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 72 15/04/16 11:49

Page 72: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

2 3

4 65

82

66

1

2

1

3

1

4

1

5

46

1

7

6

NEUTRO

FASE

Km1

Kpp1

Kpp1

P1

STANDARD ELECTRICAL SCHEME -System power: 0.77kW, single-phase

Line description Main device Lamp Line 1 km1 Auxiliaries line

Power 0.770 kW 0.770 kW 0.770 kW 0.000 kW

Operating current Ib [A] 3.72 3.72 3.72 0.00

Rated current In [A] 32.00 20.00 25.00 6.00

Article description Control switch disconnector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse holder

22x58 - 8M

Red signalling lamp with fuse holder 230V 10.3x38 - 3M

MDC60 C20 2PId=30mA A

Contactor 25A2NO -

230V AC / 220V DC2M

MDC45 C61P+N Id=30mA

AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 328 GW D6 712 GW 94 005

Breaking capacity [kA] 6.00 4.50

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 203 Polyester board with window 500X405X200 1

GW 46 421 F Panel without windows 18 mod. 2

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 436 F Pair of uprights for boards 500X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 101 1-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 1

GW 74 501 1 NO contact 10A 250V 1

GW 74 511 Lamp-holder - BA95 coupling 1

GW 74 518 Lamp - BA95 coupling 1

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 328 RCBO C.2P C20 6KA A/0.03 2M 1

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 1

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

73

PB 22359 EN Cata prog Light 0316_EN.indd 73 15/04/16 11:49

Page 73: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

-5

Ass

e y

(m)

0 5-5Asse x (m)

1

1

1

1

1

1

1

1

1

1

1 2 0 07

61 1 0

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Ceiling-mounting luminaire SMART [3]

Optic Opal

Power system (W) 51

Lumen output (lm) 5977

LED WATERTIGHT LUMINAIRE SMART[3] 1600MM GW S3 258 P

TECHNICAL DATA OF THE WATERTIGHT LUMINAIRESFloodlight assembly height (m) 4.5

Number of floodlights 10

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

WATERTIGHT LUMINAIRES POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -4.00 -1.75 0°; 0°; 90°

2 -4.00 1.75 0°; 0°; 90°

3 -2.00 -1.75 0°; 0°; 90°

4 -2.00 1.75 0°; 0°; 90°

5 0.00 -1.75 0°; 0°; 90°

6 0.00 1.75 0°; 0°; 90°

7 2.00 -1.75 0°; 0°; 90°

8 2.00 1.75 0°; 0°; 90°

9 4.00 -1.75 0°; 0°; 90°

10 4.00 1.75 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 9x5EAv [lx] 521

Emin/EAv 0.80

CRI 80

No. of luminaires 10

luminaire h. [m] 4.5

KEY500.0 lx600.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II 500 0.7 60

PLAY AREA DIMENSIONSLength [m] 9.75Width [m] 6.40Grid points (length) 9Grid points (width) 5

74

REQUISITES

IND

OO

R

Squash - 500 lx - Medium-level competitionsProject compliant with: EN 12193 (2008): Class II

PB 22359 EN Cata prog Light 0316_EN.indd 74 15/04/16 11:50

Page 74: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

32

1

65482

66

1

2

1

3

1

4

1

5

46

1

7

6

NEUTRO

FASE

Km1

Kpp1

Kpp1

P1

STANDARD ELECTRICAL SCHEME -System power: 0.50kW, single-phase

Line description Main device Lamp Line 1 km1 Auxiliaries line

Power 0.500 kW 0.500 kW 0.500 kW 0.000 kW

Operating current Ib [A] 2.42 2.42 2.42 0.00

Rated current In [A] 32.00 16.00 25.00 6.00

Article description Control switch disconnector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 8M

Red signalling lamp with fuse holder 230V 10.3x38 - 3M

MDC60 C16 2PId=30mA A

Contactor 25A2NO -

230V AC/ 220V DC -2M

MDC45 C61P+N Id=30mA

AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 327 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 4.50

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 203 Polyester board with window 500X405X200 1

GW 46 421 F Panel without windows 18 mod. 2

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 436 F Pair of uprights for boards 500X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 101 1-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 1

GW 74 501 1 NO contact 10A 250V 1

GW 74 511 Lamp-holder - BA95 coupling 1

GW 74 518 Lamp - BA95 coupling 1

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 327 RCBO C.2P C16 6KA A/0.03 2M 1

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 1

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

75

PB 22359 EN Cata prog Light 0316_EN.indd 75 15/04/16 11:50

Page 75: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

-5

Ass

e y

(m)

0 5-5Asse x (m)

1

1

1

1

1

1

1 2 0 07

61 1 0

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMPMaintenance factor 0.80

Ceiling-mounting luminaire SMART [3]

Optic Opal

Power system (W) 51

Lumen output (lm) 5977

LED WATERTIGHT LUMINAIRE SMART[3] 1600MM GW S3 258 P

WATERTIGHT LUMINAIRES POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -3.00 -1.70 0°; 0°; 90°

2 -3.00 1.70 0°; 0°; 90°

3 0.00 -1.70 0°; 0°; 90°

4 0.00 1.70 0°; 0°; 90°

5 3.00 -1.70 0°; 0°; 90°

6 3.00 1.70 0°; 0°; 90°

CALCULATION RESULTS

Lighting project for indoor sports centre.

GRID 9x5EAv [lx] 322

Emin/EAv 0.77

CRI 80

No. of luminaires 6

luminaire h. [m] 4.5

TECHNICAL DATA OF THE WATERTIGHT LUMINAIRESFloodlight assembly height (m) 4.5

No. of luminaires 6

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

KEY250.0 lx300.0 lx

350.0 lx

400.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

III 300 0.7 20

PLAY AREA DIMENSIONSLength [m] 9.75Width [m] 6.40Grid points (length) 9Grid points (width) 5

76

REQUISITES

IND

OO

R

Squash - 300 lx- Training activitiesProject compliant with: EN 12193 (2008): Class III

PB 22359 EN Cata prog Light 0316_EN.indd 76 15/04/16 11:50

Page 76: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

47

1

76582

66

1

7

1

4

1

5

1

6

57

1

8

7

NEUTRO

FASE

Km1

Kpp1

Kpp1

P1

STANDARD ELECTRICAL SCHEME -System power: 0.3kW, single-phase

Line description Main device Lamp Line 1 km1 Auxiliaries line

Power 0.300 kW 0.300 kW 0.300 kW 0.000 kW

Operating current Ib [A] 1.45 1.45 1.45 0.00

Rated current In [A] 32.00 10.00 25.00 6.00

Article description Control switch disconnector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 8M

Red signalling lamp with fuse holder 230V 10.3x38 - 3M

MDC60 C10 2PId=30mA A

Contactor 25A2NO -

230V AC / 220V DC2M

MDC45 C61P+N Id=30mA

AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 326 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 4.50

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 203 Polyester board with window 500X405X200 1

GW 46 421 F Panel without windows 18 mod. 2

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 436 F Pair of uprights for boards 500X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

Standard puSh-button control panel PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 101 1-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 1

GW 74 501 1 NO contact 10A 250V 1

GW 74 511 Lamp-holder - BA95 coupling 1

GW 74 518 Lamp - BA95 coupling 1

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 326 RCBO C.2P C10 6KA A/0.03 2M 1

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 1

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 1

Standard auxiliarieS circuit

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

77

PB 22359 EN Cata prog Light 0316_EN.indd 77 15/04/16 11:50

Page 77: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

0 5 10 15-5-10-15

Asse x (m)

-20 20

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 2 0 07

61 1 0

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMP Maintenance factor 0.80

Ceiling-mounting luminaire SMART [3]

Optic Transparent

Power system (W) 51

Lumen output (lm) 6453

TECHNICAL DATA OF THE WATERTIGHT LUMINAIRESFloodlight assembly height (m) 4.5

No. of luminaires 16

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

WATERTIGHT LUMINAIRES POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -12.25 -1.00 0°; 0°; 90°2 -12.25 1.00 0°; 0°; 90°3 -8.75 -1.00 0°; 0°; 90°4 -8.75 1.00 0°; 0°; 90°5 -5.25 -1.00 0°; 0°; 90°6 -5.25 1.00 0°; 0°; 90°7 -1.75 -1.00 0°; 0°; 90°8 -1.75 1.00 0°; 0°; 90°9 1.75 -1.00 0°; 0°; 90°

10 1.75 1.00 0°; 0°; 90°11 5.25 -1.00 0°; 0°; 90°12 5.25 1.00 0°; 0°; 90°13 8.75 -1.00 0°; 0°; 90°14 8.75 1.00 0°; 0°; 90°15 12.25 -1.00 0°; 0°; 90°16 12.25 1.00 0°; 0°; 90°

CALCULATION RESULTS

LED WATERTIGHT LUMINAIRE SMART[3] 1600MM GW S3 258 T

GRID 11x4EAv [lx] 308

Emin/EAv 0.73

CRI 80

No. of luminaires 16

luminaire h. [m] 4.5

Lighting project for indoor sports centre.

KEY50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx

300.0 lx

350.0 lx

400.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

I 300 0.7 60

PLAY AREA DIMENSIONSLength [m] 27.5Width [m] 4Grid points (length) 15Grid points (width) 4

78

REQUISITES

IND

OO

R

Bocce - 300 lxMedium-level competitions - Training ActivitiesProject compliant with: EN 12193 (2008): Class I

PB 22359 EN Cata prog Light 0316_EN.indd 78 15/04/16 11:50

Page 78: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

2 3

4 65

85

132

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

1

2

1

3

1

4

1

5

46

1

7

6

STANDARD ELECTRICAL SCHEME -System power: 0.82kW, single-phase

Line description Main device Lamp Line 1 km1 Auxiliaries line

Power 0.82 kW 0.82 kW 0.82 kW 0.000 kW

Operating current Ib [A] 3.96 3.96 3.96 0.00

Rated current In [A] 32.00 20.00 25.00 6.00

Article description Control switch disconnector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 8M

Red signalling lamp with fuse holder 230V 10.3x38 - 3M

MDC60 C20 2PId=30mA A

Contactor 25A2NO - 230V AC/ 220V DC - 2M

MDC45 C61P+N Id=30mA

AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 328 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 4.50

Standard diStribution board DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 203 Polyester board with window 500X405X200 1

GW 46 421 F Panel without windows 18 mod. 2

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 436 F Pair of uprights for boards 500X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Standard puSh-button control panel

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 328 RCBO C.2P C20 6KA A/0.03 2M 1

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW 96 623 Latching relay 1NO 16A 230V 1

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 1

Standard auxiliarieS circuit

79

PB 22359 EN Cata prog Light 0316_EN.indd 79 15/04/16 11:50

Page 79: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

05

10-5

-10

Ass

e y

(m)

0 5 10 15-5-10-15

Asse x (m)

-20 20

1 1 1 1 1 1 1 1 1 1 1 1

1 2 0 07

61 1 0

PROPOSED SOLUTION

TECHNICAL DATA OF THE LAMP Maintenance factor 0.80

Ceiling-mounting luminaire SMART [3]

Optic Transparent

Power system (W) 51

Lumen output (lm) 6453

TECHNICAL DATA OF THE WATERTIGHT LUMINAIRESFloodlight assembly height (m) 4.5

No. of luminaires 12

The lighting values actually measured may differ from the project ones due to the intrinsic tolerance levels of the light sources and devices, for their orientation, and for the different electricity supply parameters.

WATERTIGHT LUMINAIRES POSITIONING

Device Position of devices in X

Position of devices in Y Device rotation X°; Y°; Z°

1 -13.75 0.00 0°; 0°; 90°

2 -11.25 0.00 0°; 0°; 90°

3 -8.75 0.00 0°; 0°; 90°

4 -6.25 0.00 0°; 0°; 90°

5 -3.75 0.00 0°; 0°; 90°

6 -1.25 0.00 0°; 0°; 90°

7 1.25 0.00 0°; 0°; 90°

8 3.75 0.00 0°; 0°; 90°

9 6.25 0.00 0°; 0°; 90°

10 8.75 0.00 0°; 0°; 90°

11 11.25 0.00 0°; 0°; 90°

12 13.75 0.00 0°; 0°; 90°

CALCULATION RESULTS

LED WATERTIGHT LUMINAIRE SMART[3] 1600MM GW S3 258 T

GRID 11x4EAv [lx] 228

Emin/EAv 0.71

CRI 80

No. of luminaires 12

luminaire h. [m] 4.5

Lighting project for indoor sports centre.

KEY50.0 lx

100.0 lx150.0 lx200.0 lx250.0 lx300.0 lx

VALUES REQUIRED

Class EAv [lx] Emin/EAv Colour rendering index [CRI]

II - III 200 0.5 - 0.7 60 - 20

PLAY AREA DIMENSIONSLength [m] 27.5Width [m] 4Grid points (length) 15Grid points (width) 4

80

REQUISITES

IND

OO

R

Bocce - 200 lxMedium-level competitions - Training ActivitiesProject compliant with: EN 12193 (2008): Class II – III

PB 22359 EN Cata prog Light 0316_EN.indd 80 15/04/16 11:50

Page 80: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1

2 3

4 65

85

132

P1

Kpp1

NEUTRO

Kpp1

Km1

FASE

Km2

Kpp2

Kpp2

P2

1

2

1

3

1

4

1

5

46

1

7

6

STANDARD ELECTRICAL SCHEME -System power: 0.62kW, single-phase

Line description Main device Lamp Line 1 km1 Auxiliaries line

Power 0.620 kW 0.620 kW 0.620 kW 0.000 kW

Operating current Ib [A] 3.00 3.00 3.00 0.00

Rated current In [A] 32.00 16.00 25.00 6.00

Article description Control switch disconnector 2P 32A

Surge protective device 1P+N 25kA Aux. Type 1+2 + fuse

holder 22x58 - 8M

Red signalling lamp with fuse holder 230V 10.3x38 - 3M

MDC60 C16 2PId=30mA A

Contactor 25A2NO -

230V AC/ 220V DC -2M

MDC45 C61P+N Id=30mA

AC

Code GW 96 114 GW D6 404 GW 96 581 GW 94 327 GW D6 712 GW 94 005

Breaking capacity Icn/Icu [kA] 6.00 4.50

Standard diStribution board

The electrical scheme shown here is merely an example; it can be modified to suit the installation requirements. It should not be considered as a substitute for the necessary electrical project, which must be based on the technical standards.

Standard puSh-button control panel

Standard auxiliarieS circuit

DISTRIBUTION BOARD COMPONENTSCode Description Qty

GW 44 691 2-pole terminal block 4 MOD.EN 50022 1

GW 46 203 Polyester board with window 500X405X200 1

GW 46 421 F Panel without windows 18 mod. 2

GW 46 426 F Blank panel 1M. 405MM GR.RAL7035 1

GW 46 436 F Pair of uprights for boards 500X405X200 1

GW 46 531 F Quick-assembly double rail 18M 1

PUSH-BUTTON PANEL COMPONENTSCode Description Qty

GW 27 102 2-gang push-button panel IP66 1

GW 74 341 Illuminated green push-button 2

GW 74 501 1 NO contact 10A 250V 2

GW 74 511 Lamp-holder - BA95 coupling 2

GW 74 518 Lamp - BA95 coupling 2

COMPONENTS OF THE ELECTRICAL SCHEME AND AUXILIARIES CIRCUITCode Description Qty

GW 72 104 Cylindrical fuse type GG 10.3X38 500V 2A 1

GW 94 005 RCBO C.1P+N C 6 4.5KA AC/0.03 2M 1

GW 94 327 RCBO C.2P C16 6KA A/0.03 2M 1

GW 96 114 Switch disconnector 2P 32A AC23B 1

GW 96 215 Disconnectable fuse holder 1P+N 10.3X38 400V 32A 1

GW 96 218 Disconnectable fuse holder 1P+N 22X58 690V 1

GW 96 581 Single red indicator lamp 230V 1M 1

GW D6 644 Latching relay 1NO 16A 230V 1

GW D6 404 Surge protective device 1P+N 25KA AUX TYPE 1+2 1

GW D6 712 Contactor 25A 2NO 230V 2M 1

81

PB 22359 EN Cata prog Light 0316_EN.indd 81 15/04/16 11:50

Page 81: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 LOW VOLTAGE DISTRIBUTION BOARD 2 BOARDS 3 WIRING 4 DOMESTIC RANGE 5 DISTRIBUTION SYSTEMS 6 COMMAND SYSTEMS 7 CONNECTION SYSTEMS 8 LIGHTING 9 DOMOTICS

DIST

RIBU

TION

BOA

RDS

UP

TO 1

,600

A

SECO

NDAR

Y

DIST

RIBU

TION

BOA

RDS

NETW

ORK

CA

BLIN

G

COM

MAN

DS

ENER

GY S

OCKE

T-OU

TLET

S

DATA

SOC

KET-

OUTL

ETS

TEM

PERA

TURE

ADJ

USTM

ENT

TECH

NICA

L ALA

RMS

COND

UITS

JUNC

TION

BOX

ES

(FLU

SH-M

OUNT

ING/

SU

RFAC

E-M

OUNT

ING)

C OM

PONE

NT-H

OLDE

R BO

XES

(F

LUSH

-MOU

NTIN

G/SU

RFAC

E-M

OUNT

ING)

FLOO

R OU

TLET

BOX

ES

COM

MAN

D AN

D

EMER

GENC

Y SY

STEM

S

IB S

OCKE

T-OU

TLET

DIS

TRIB

UTIO

N AN

D CO

NNEC

TION

SYS

TEM

S

INDO

OR L

IGHT

ING

OUTD

OOR

LIGH

TING

SUPE

R VIS

ION

LIGH

TING

CON

TROL

DRIV

E CO

NTRO

L (H

OPPE

R W

INDO

WS/

BLIN

DS)

TEM

PERA

TURE

ADJ

USTM

ENT

ENER

GY M

ANAG

EMEN

T

TECH

NICA

L ALA

RMS

SCEN

ES

CHANGING ROOM

STAND

ACCESS PATH

PARKING AREA

TECHNICAL PREMISES

STOREHOUSE

OFFICES

82

COM

PLE

MEN

TAR

Y A

RE

AS

An overview of the GEWISS range

Apart from lighting devices, the GEWISS range also includes solutions for protec-tion, management, connection and energy distribution: 20,000 products offering professionals the possibility to design complete systems for all sports facilities service infrastructures.

PB 22359 EN Cata prog Light 0316_EN.indd 82 15/04/16 11:50

Page 82: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1 LOW VOLTAGE DISTRIBUTION BOARD 2 BOARDS 3 WIRING 4 DOMESTIC RANGE 5 DISTRIBUTION SYSTEMS 6 COMMAND SYSTEMS 7 CONNECTION SYSTEMS 8 LIGHTING 9 DOMOTICS

DIST

RIBU

TION

BOA

RDS

UP

TO 1

,600

A

SECO

NDAR

Y

DIST

RIBU

TION

BOA

RDS

NETW

ORK

CA

BLIN

G

COM

MAN

DS

ENER

GY S

OCKE

T-OU

TLET

S

DATA

SOC

KET-

OUTL

ETS

TEM

PERA

TURE

ADJ

USTM

ENT

TECH

NICA

L ALA

RMS

COND

UITS

JUNC

TION

BOX

ES

(FLU

SH-M

OUNT

ING/

SU

RFAC

E-M

OUNT

ING)

C OM

PONE

NT-H

OLDE

R BO

XES

(F

LUSH

-MOU

NTIN

G/SU

RFAC

E-M

OUNT

ING)

FLOO

R OU

TLET

BOX

ES

COM

MAN

D AN

D

EMER

GENC

Y SY

STEM

S

IB S

OCKE

T-OU

TLET

DIS

TRIB

UTIO

N AN

D CO

NNEC

TION

SYS

TEM

S

INDO

OR L

IGHT

ING

OUTD

OOR

LIGH

TING

SUPE

R VIS

ION

LIGH

TING

CON

TROL

DRIV

E CO

NTRO

L (H

OPPE

R W

INDO

WS/

BLIN

DS)

TEM

PERA

TURE

ADJ

USTM

ENT

ENER

GY M

ANAG

EMEN

T

TECH

NICA

L ALA

RMS

SCEN

ES

CHANGING ROOM

STAND

ACCESS PATH

PARKING AREA

TECHNICAL PREMISES

STOREHOUSE

OFFICES

83

PB 22359 EN Cata prog Light 0316_EN.indd 83 15/04/16 11:50

Page 83: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

PLAY AREA7-A-SIDE

NORTH STANDS

LOCAL LOCKER ROOM

REFEREE LOCKER ROOM

REFEREE LOCKER ROOM

TECHNICAL ROOM

OFFICE

NO

RTH PED

ESTRIAN AREA

SOUTH

PEDESTRIAN

AREA

PARKING AREA

WAREHOUSE

GUEST LOCKER ROOM

SOUTH STANDS

1

4

4

4 7

7

2

2

5

5

5

8

8

8

3

3

9

9

9

4

4

7

7

7

5

5

5

8

8

8

6

6

9

9

9

KEY

1 LOW VOLTAGE DISTRIBUTION BOARD2 BOARDS3 WIRING4 DOMESTIC RANGE5 DISTRIBUTION SYSTEMS

6 COMMAND SYSTEMS7 CONNECTION SYSTEMS8 LIGHTING9 DOMOTICS

84

COM

PLE

MEN

TAR

Y A

RE

AS

Standard example of sports facilities layout

PB 22359 EN Cata prog Light 0316_EN.indd 84 15/04/16 11:51

Page 84: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

PLAY AREA7-A-SIDE

NORTH STANDS

LOCAL LOCKER ROOM

REFEREE LOCKER ROOM

REFEREE LOCKER ROOM

TECHNICAL ROOM

OFFICE

NO

RTH PED

ESTRIAN AREA

SOUTH

PEDESTRIAN

AREA

PARKING AREA

WAREHOUSE

GUEST LOCKER ROOM

SOUTH STANDS

4

4

4

4

2

2

2

2

5

5

5

5

8

8

8

8

9

9

9

9

7

7

5

5

8

8

9

9

85

PB 22359 EN Cata prog Light 0316_EN.indd 85 15/04/16 11:51

Page 85: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

1.1 PARKING AREA

1.1.1 Lighting

GW R5 272 ROAD [5] 2M 4000K 700mA 20 pcs

GW 84 097 CONICAL STEEL HIGH MAST H=7M ABOVE GROUND 20 pcs

1.1.2 Power take-off outlet box

GW 20 246 SOCKET-OUTLET 2P+E 16A DUAL AMP. ITALIAN/GERMAN STD. SY/WT 2 pcs

GW 27 403 2-GANG BLANK WATERTIGHT CAP SYSTEM 2 pcs

GW 66 304 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.2P+E 16A 230V 6H SBF 1 pcs

GW 66 309 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.3P+N+E 16A 400V 6H SBF 1 pcs

GW 66 709 N FLANGED COVER, 2 CAPS IP67 1 pcs

GW 68 715 A EMPTY PEDESTALS WITH SINGLE-SIDED TAKE-OFF QMC 125B LIGHT BLUE 1 pcs

GW 68 731 W PANEL 3 INTERLOCKED SWITCHED SOCKET-OUTLETS VERT. IP55 BIA 1 pcs

GW 68 741 A PANEL WITH ENCLOSURE AZ 1 pcs

GW 68 765 TERMINAL BLOCK FOR QMC: CABLES UP TO 16SQ.MM 1 pcs

GW 94 167 RCBO C.4P C16 6KA AC/0.03 4M 2 pcs

GW 96 135 CONTROL SWITCH DISCONNECTOR 4P 40A 1 pcs

1.1.3 Routing and boxes

DX 59 401 ELECTRICAL BOX 200X200 12 pcs

DX 35 003 FU15/ 75R.50M FLEXIBLE CABLE DUCT 300 m

DX 58 203 FUM/ 75 COUPLING 12 pcs

1.2 NORTH STANDS

1.2.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 40 pcs

1.2.2 Routing and boxes

DX 25 732 RKB32-3M HEAVY SOLID CONDUIT, GREY 50 m

DX 43 232 MS 32 MORBIDX BOX-CONDUIT COUPLING 40 pcs

DX 25 720 RKB20-3M HEAVY SOLID CONDUIT, GREY 10 m

DX 43 220 MS 20 MORBIDX BOX-CONDUIT COUPLING 44 pcs

GW 44 208 BOX IP56 SMOOTH WALLS 240X190X90 20 pcs

GW 50 604 SNAP-ON SUPPORT FOR CONDUIT D.32 GR.RAL7035 25 pcs

GW 50 602 SNAP-ON SUPPORT FOR CONDUIT D.20 GR.RAL7035 5 pcs

1.2.3 Socket-outlets

GW 66 204 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 C.F.2P+E 16A 230V 6H SBF 1 pcs

GW 66 209 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 C.F.3P+N+E 16A 400V 6H SBF 1 pcs

1.3 SOUTH STANDS

1.3.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 40 pcs

1.3.2 Routing and boxes

DX 25 732 RKB32-3M HEAVY SOLID CONDUIT, GREY 50 m

DX 43 232 MS 32 MORBIDX BOX-CONDUIT COUPLING 40 pcs

DX 25 720 RKB20-3M HEAVY SOLID CONDUIT, GREY 10 m

DX 43 220 MS 20 MORBIDX BOX-CONDUIT COUPLING 44 pcs

GW 44 208 BOX IP56 SMOOTH WALLS 240X190X90 20 pcs

GW 50 604 SNAP-ON SUPPORT FOR CONDUIT D.32 GR.RAL7035 25 pcs

GW 50 602 SNAP-ON SUPPORT FOR CONDUIT D.20 GR.RAL7035 5 pcs

1.3.3 Socket-outlets

GW 66 204 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 C.F.2P+E 16A 230V 6H SBF 1 pcs

GW 66 209 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 C.F.3P+N+E 16A 400V 6H SBF 1 pcs

1.4 PEDESTRIANS AREA

1.4.1 Lighting

GW S2 401 EXTRO LED 13W 4000K 220-240V 50-60HZ G 20 pcs

GW 82 292 EXTRO COLUMN SING.H.1300 GRAPHITE GREY 20 pcs

GW 82 297 RECTANGULAR BASE FOR EXTRO COLUMN GRAPHITE GREY 20 pcs

1.4.2 Routing and boxes

DX 59 401 ELECTRICAL BOX 200X200 6 pcs

DX 35 003 FU15/ 75R.50M FLEXIBLE CABLE DUCT 90 m

DX 58 203 FUM/ 75 COUPLING 6 pcs

1.4.3 Commands

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 2 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 2 pcs

GW 10 195 BLANKING MODULE 1M WHITE 2 pcs

GW 10 051 TWO-WAY SWITCH 1M 1P 16AX WHITE 4 pcs

GW 42 201 WATERTIGHT ENCLOSURE FOR EMERGENCY SYSTEMS, WITH PUSH-BUTTON 2 pcs

1.4.4 Power take-off outlet box

GW 20 246 SOCKET-OUTLET 2P+E 16A DUAL AMP. ITALIAN/GERMAN STD. SY/WT 2 pcs

GW 27 403 2-GANG BLANK WATERTIGHT CAP SYSTEM 2 pcs

GW 66 304 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.2P+E 16A 230V 6H SBF 1 pcs

GW 66 309 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.3P+N+E 16A 400V 6H SBF 1 pcs

GW 66 709 N FLANGED COVER, 2 CAPS IP67 1 pcs

GW 68 715 A EMPTY PEDESTALS WITH SINGLE-SIDED TAKE-OFF QMC 125B LIGHT BLUE 1 pcs

Code Description Qty Code Description Qty

86

COM

PLE

MEN

TAR

Y A

RE

AS

List of products

PB 22359 EN Cata prog Light 0316_EN.indd 86 15/04/16 11:51

Page 86: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

GW 68 731 W PANEL 3 INTERLOCKED SWITCHED SOCKET-OUTLETS VERT. IP55 BIA 1 pcs

GW 68 741 A PANEL WITH ENCLOSURE AZ 1 pcs

GW 68 765 TERMINAL BLOCK FOR QMC: CABLES UP TO 16SQ.MM 1 pcs

GW 94 167 RCBO C.4P C16 6KA AC/0.03 4M 2 pcs

GW 96 135 CONTROL SWITCH DISCONNECTOR 4P 40A 1 pcs

1.5 WAREHOUSE

1.5.1 Lighting

GW S3 236 T SMART [3] - 1200mm - 39W 12 pcs

1.5.2 Control panel

GW 40 045 DECORATIVE ENCLOSURE 12M IP40 1 pcs

GW 90 090 COMPACT MCB 4P C32 4.5KA 2M 1 pcs

GW 90 286 COMPACT MCB 4P C10 6KA 2M 1 pcs

GW D4 122 RCCB 4P 40A AC/0.03 4M 1 pcs

1.5.3 Socket-outlet board

GW 20 246 SOCKET-OUTLET 2P+E 16A DUAL AMP. ITALIAN/GERMAN STD. SY/WT 8 pcs

GW 27 403 2-GANG BLANK WATERTIGHT CAP SYSTEM 8 pcs

GW 46 446 SET OF 4 GALVANISED STEEL BRACKETS FOR FIXING SURFACE-MOUNTING BOARDS 4 pcs

GW 66 304 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.2P+E 16A 230V 6H SBF 4 pcs

GW 66 320 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.3P+N+E 32A 400V 6H SBF 4 pcs

GW 66 709 N FLANGED COVER, 2 CAPS IP67 4 pcs

GW 68 010 N Q-DIN 14M 3 FLANGES VERTICAL INTERLOCKED SOCKET-OUTLET SBF IP65 4 pcs

GW 90 247 COMPACT MCB 2P C16 6KA 1M 12 pcs

GW 90 290 COMPACT MCB 4P C32 6KA 2M 4 pcs

GW D4 122 RCCB 4P 40A AC/0.03 4M 4 pcs

1.5.4 Routing and boxes

DX 25 720 RKB20-3M HEAVY SOLID CONDUIT, GREY 150 m

DX 40 220 RKT/20G T-JOINT FOR INSPECTIONS, GREY 25 pcs

DX 43 220 MS 20 MORBIDX BOX-CONDUIT COUPLING 42 pcs

DX 40 120 RKS/20G NARROW RADIUS ELBOW 6 pcs

GW 44 204 BOX IP56 SMOOTH WALLS 100X100X50 3 pcs

GW 44 209 BOX IP56 SMOOTH WALLS 300X220X120 4 pcs

GW 50 602 SNAP-ON SUPPORT FOR CONDUIT D.20 GR.RAL7035 75 pcs

1.5.5 Commands

GW 27 003 3-GANG HORIZ. WATERTIGHT CONTAINER 2 pcs

GW 20 576 TWO-WAY SWITCH 1P 16AX SY/WT 2 pcs

GW 20 056 BLANKING MODULE, 1 MODULE SY/WT 4 pcs

GW 70 403 BOX ROTARY SWITCH ISO.4P 16A BLACK HANDLE 1 pcs

1.6 LOCAL LOCKER ROOM

1.6.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 11 pcs

GW S2 801 ASTRID 75 - 11.5W LED G2 350mA WHITE 6 pcs

1.6.2 Control panel

GW 40 225 TB DECORATIVE ENCLOSURE 8M MILK WHITE 1 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

GW 90 027 COMPACT MCB 1P+N C16 4.5KA 1M 1 pcs

GW 94 008 RCBO C.1P+N C20 4.5KA AC/0.03 2M 1 pcs

1.6.3 Routing and boxes

DX 15 120 FK15/20F MEDIUM PLIABLE CONDUIT, BLACK, WITH PROBE 100 m

GW 48 005 FLUSH-MOUNTING JUNCTION BOX 160X130X70 2 pcs

1.6.4 Commands

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 8 pcs

GW 10 195 BLANKING MODULE 1M WHITE 16 pcs

GW 10 001 ONE-WAY SWITCH 1M 1P 16AX WHITE 8 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 8 pcs

1.6.5 Socket-outlets

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 4 pcs

GW 10 195 BLANKING MODULE 1M WHITE 4 pcs

GW 10 204 SOCKET-OUTLET 2M 2P+E 16A DUAL AMP.P30-17 ITAL-IAN/GERMAN STD.B. 4 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 4 pcs

1.6.6 Temperature adjustment

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 1 pcs

GW 10 703 FLUSH-MOUNTING TIMED THERMOSTAT 2M 230V AC, WHITE 1 pcs

1.7 GUEST LOCKER ROOM

1.7.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 11 pcs

GW S2 801 ASTRID 75 - 11.5W LED G2 350mA WHITE 6 pcs

1.7.2 Control panel

GW 40 225 TB DECORATIVE ENCLOSURE 8M MILK WHITE 1 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

Code Description Qty Code Description Qty

87

PB 22359 EN Cata prog Light 0316_EN.indd 87 15/04/16 11:51

Page 87: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

GW 90 027 COMPACT MCB 1P+N C16 4.5KA 1M 1 pcs

GW 94 008 RCBO C.1P+N C20 4.5KA AC/0.03 2M 1 pcs

1.7.3 Routing and boxes

DX 15 120 FK15/20F MEDIUM PLIABLE CONDUIT, BLACK, WITH PROBE 100 m

GW 48 005 FLUSH-MOUNTING JUNCTION BOX 160X130X70 2 pcs

1.7.4 Commands

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 8 pcs

GW 10 195 BLANKING MODULE 1M WHITE 16 pcs

GW 10 001 ONE-WAY SWITCH 1M 1P 16AX WHITE 8 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 8 pcs

1.7.5 Socket-outlets

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 4 pcs

GW 10 195 BLANKING MODULE 1M WHITE 4 pcs

GW 10 204 SOCKET-OUTLET 2M 2P+E 16A DUAL AMP.P30-17 ITALIAN/GERMAN STD.B. 4 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 4 pcs

1.7.6 Temperature adjustment

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 1 pcs

GW 10 703 FLUSH-MOUNTING TIMED THERMOSTAT 2M 230V AC, WHITE 1 pcs

1.8 TECHNICAL ROOM

1.8.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 4 pcs

1.8.2 Control panel

GW 44 698 4-POLE TERMINAL BLOCK 8 MOD. EN 50022 1 pcs

GW 45 057 CVX630M - STRUCTURE 600X1600 1 pcs

GW 45 077 CVX630M - PAIR OF SIDE PANELS H1600 1 pcs

GW 45 157 CVX630M - GLASS DOOR IP55 600X1600 1 pcs

GW 45 202 CVX630K - DIN PANEL KIT 600X200 7 pcs

GW 45 304 CVX630K - SOLID PANEL 600X200 1 pcs

GW 45 412 CVX630K - PROFILE G32 B600 1 pcs

GW 45 526 CVX630K - 2 HORIZ. TERMINAL BLOCK SUPPORTS 45° 1 pcs

GW 47 491 CVX630 - BRACKETS FOR SURFACE-MOUNTING 1 pcs

GW 72 104 CYLINDRICAL FUSE TYPE GG 10.3X38 500V 2A 6 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

GW 90 028 COMPACT MCB 1P+N C20 4.5KA 1M 5 pcs

GW 92 046 MINIATURE CIRCUIT BREAKER 2P C10 6KA 2M 1 pcs

GW 92 086 MINIATURE CIRCUIT BREAKER 4P C10 6KA 4M 5 pcs

GW 92 087 MINIATURE CIRCUIT BREAKER 4P C16 6KA 4M 2 pcs

GW 92 088 MINIATURE CIRCUIT BREAKER 4P C20 6KA 4M 1 pcs

GW 92 089 MINIATURE CIRCUIT BREAKER 4P C25 6KA 4M 2 pcs

GW 92 090 MINIATURE CIRCUIT BREAKER 4P C32 6KA 4M 4 pcs

GW 92 091 MINIATURE CIRCUIT BREAKER 4P C40 6KA 4M 3 pcs

GW 92 093 MINIATURE CIRCUIT BREAKER 4P C63 6KA 4M 1 pcs

GW 94 422 RESIDUAL CURRENT DEVICE 4P IN<25A INSTANT.AC/0.03 3.5M 6 pcs

GW 94 423 RESIDUAL CURRENT DEVICE 4P IN<25A INSTANT.AC/0.3 3.5M 1 pcs

GW 94 432 RESIDUAL CURRENT DEVICE 4P IN<63A INSTANT.AC/0.03 3.5M 3 pcs

GW 94 433 RESIDUAL CURRENT DEVICE 4P IN<63A INSTANT.AC/0.3 3.5M 1 pcs

GW 96 312 DISCONNECTABLE FUSE HOLDER 3P+N 10.3X38 690V 32A 2 pcs

GW 96 446 CURRENT TRANSFORMER 100A 3 pcs

GW 96 581 SINGLE RED INDICATOR LAMP 230V 1M 3 pcs

GW 96 897 VOLTAGE/CURRENT MULTIMETER 1 pcs

GW D4 124 RCCB 4P 40A AC/0.3 4M 1 pcs

1.8.3 Socket-outlet board

GW 20 246 SOCKET-OUTLET 2P+E 16A DUAL AMP. ITALIAN/GERMAN STD. SY/WT 2 pcs

GW 27 403 2-GANG BLANK WATERTIGHT CAP SYSTEM 2 pcs

GW 46 446 SET OF 4 GALVANISED STEEL BRACKETS FOR FIXING SURFACE-MOUNTING BOARDS 1 pcs

GW 66 304 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.2P+E 16A 230V 6H SBF 1 pcs

GW 66 320 N INTERLOCKED SWITCHED SOCKET-OUTLET IP67 S.F.3P+N+E 32A 400V 6H SBF 1 pcs

GW 66 709 N FLANGED COVER, 2 CAPS IP67 1 pcs

GW 68 010 N Q-DIN 14M 3 FLANGES VERTICAL INTERLOCKED SOCKET-OUTLET SBF IP65 1 pcs

GW 90 247 COMPACT MCB 2P C16 6KA 1M 3 pcs

GW 90 290 COMPACT MCB 4P C32 6KA 2M 1 pcs

GW D4 122 RCCB 4P 40A AC/0.03 4M 1 pcs

1.8.4 Routing and boxes

DX 25 720 RKB20-3M HEAVY SOLID CONDUIT, GREY 15 m

DX 40 220 RKT/20G T-JOINT FOR INSPECTIONS, GREY 2 pcs

DX 43 220 MS 20 MORBIDX BOX-CONDUIT COUPLING 4 pcs

DX 40 120 RKS/20G NARROW RADIUS ELBOW 1 pcs

GW 44 206 BOX IP56 SMOOTH WALLS 150X110X70 2 pcs

GW 50 602 SNAP-ON SUPPORT FOR CONDUIT D.20 GR.RAL7035 8 pcs

1.8.5 LAN board

GW 38 431 SOHO LAN BOARD 10'' 400x350x265 8U 1 pcs

GW 38 441 SOHO PANEL 10'' SUPPLY SOCKET-OUTLETS 1 pcs

GW 38 437 UNWIRED PANEL FOR 8 CONNECTORS 2 pcs

GW 38 012 RJ45 SOCKET CAT.5e UTP TOOL LESS 16 pcs

GW 38 189 CABLE LSZH CAT.5E UTP 24 AWG 50 m

GW 38 439 SOHO BRACKET 10'' MINI HUB 1 pcs

GW 38 440 SOHO PANEL 10'' CABLE GLANDS 1 pcs

GW 38 117 CORD RJ45-RJ45 CAT.5E UTP 1M WHITE 16 pcs

1.8.6 Commands

GW 27 003 3-GANG HORIZ. WATERTIGHT CONTAINER 1 pcs

GW 20 056 BLANKING MODULE, 1 MODULE SY/WT 2 pcs

GW 20 571 ONE-WAY SWITCH 1P 16AX SY/WT 1 pcs

GW 70 403 BOX ROTARY SWITCH ISO.4P 16A BLACK HANDLE 2 pcs

1.9 OFFICE

1.9.1 Lighting

GW S2 506 ASTRID 60X60 DIFFUSED OPTIC 36W LED 4000K WHITE 4 pcs

1.9.2 Control panel

GW 40 225 TB DECORATIVE ENCLOSURE 8M MILK WHITE 1 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

Code Description Qty Code Description Qty

88

Metric calculation

PB 22359 EN Cata prog Light 0316_EN.indd 88 15/04/16 11:51

Page 88: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

GW 90 027 COMPACT MCB 1P+N C16 4.5KA 1M 1 pcs

GW 94 328 P ONE-WAY SWITCH MDC+RESTART RMPRO 2P20A 6 0.03-A-4M 1 pcs

1.9.3 Routing and boxes

DX 15 120 FK15/20F MEDIUM PLIABLE CONDUIT, BLACK, WITH PROBE 60 m

GW 48 005 FLUSH-MOUNTING JUNCTION BOX 160X130X70 1 pcs

1.9.4 Commands

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 2 pcs

GW 10 001 ONE-WAY SWITCH 1M 1P 16AX WHITE 1 pcs

1.9.5 Socket-outlets

GW 16 103 TB ONE PLATE 3P MILK WHITE 3 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 3 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 3 pcs

GW 10 203 SOCKET-OUTLET 1M 2P+E 16A DUAL AMP.P17-11 ITALIAN STD.WHITE 3 pcs

GW 10 204 SOCKET-OUTLET 2M 2P+E 16A DUAL AMP.P30-17 ITAL-IAN/GERMAN STD.B. 3 pcs

1.9.6 Underfloor outlet box

GW 24 611 UNDERFLOOR OUTLET BOX 10P STAINLESS STEEL COVER 1 pcs

GW 20 271 DATA CONNECTOR RJ45 CAT.5e UTP SY/WT 3 pcs

GW 20 251 TELEPHONE CONNECTOR RJ11 SY/WT 2 pcs

GW 20 246 SOCKET-OUTLET 2P+E 16A DUAL AMP. ITALIAN/GERMAN STD. SY/WT 2 pcs

GW 20 203 SOCKET-OUTLET 2P+E 16A 230V ITALIAN/GERMAN 1 pcs

1.9.7 Temperature adjustment

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 1 pcs

GW 10 703 FLUSH-MOUNTING TIMED THERMOSTAT 2M 230V AC, WHITE 1 pcs

1.10 REFEREE LOCKER ROOM

1.10.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 2 pcs

GW S2801 ASTRID 75 - 11.5W LED G2 350mA WHITE 1 pcs

1.10.2 Control panel

GW 40 225 TB DECORATIVE ENCLOSURE 8M MILK WHITE 1 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

GW 90 027 COMPACT MCB 1P+N C16 4.5KA 1M 1 pcs

GW 94 008 RCBO C.1P+N C20 4.5KA AC/0.03 2M 1 pcs

1.10.3 Routing and boxes

DX 15 120 FK15/20F MEDIUM PLIABLE CONDUIT, BLACK, WITH PROBE 60 m

GW 48 005 FLUSH-MOUNTING JUNCTION BOX 160X130X70 1 pcs

1.10.4 Commands

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 2 pcs

GW 10 195 BLANKING MODULE 1M WHITE 4 pcs

GW 10 001 ONE-WAY SWITCH 1M 1P 16AX WHITE 2 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 2 pcs

1.10.5 Socket-outlets

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 3 pcs

GW 10 195 BLANKING MODULE 1M WHITE 3 pcs

GW 10 204 SOCKET-OUTLET 2M 2P+E 16A DUAL AMP.P30-17 ITAL-IAN/GERMAN STD.B. 3 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 3 pcs

1.10.6 Temperature adjustment

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 1 pcs

GW 10 703 FLUSH-MOUNTING TIMED THERMOSTAT 2M 230V AC, WHITE 1 pcs

1.11 REFEREE LOCKER ROOM

1.11.1 Lighting

GW S3 136 T SMART [3] - 1200mm - 20W 2 pcs

GW S2 801 ASTRID 75 - 11.5W LED G2 350mA WHITE 1 pcs

1.11.2 Control panel

GW 40 225 TB DECORATIVE ENCLOSURE 8M MILK WHITE 1 pcs

GW 90 026 COMPACT MCB 1P+N C10 4.5KA 1M 1 pcs

GW 90 027 COMPACT MCB 1P+N C16 4.5KA 1M 1 pcs

GW 94 008 RCBO C.1P+N C20 4.5KA AC/0.03 2M 1 pcs

1.11.3 Routing and boxes

DX 15 120 FK15/20F MEDIUM PLIABLE CONDUIT, BLACK, WITH PROBE 60 m

GW 48 005 FLUSH-MOUNTING JUNCTION BOX 160X130X70 1 pcs

1.11.4 Commands

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 2 pcs

GW 10 195 BLANKING MODULE 1M WHITE 4 pcs

GW 10 001 ONE-WAY SWITCH 1M 1P 16AX WHITE 2 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 2 pcs

1.11.5 Socket-outlets

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 3 pcs

GW 10 195 BLANKING MODULE 1M WHITE 3 pcs

GW 10 204 SOCKET-OUTLET 2M 2P+E 16A DUAL AMP.P30-17 ITAL-IAN/GERMAN STD.B. 3 pcs

GW 16 703 TB WATERTIGHT PLATE 3P IP55 WHITE 3 pcs

1.11.6 Temperature adjustment

GW 16 103 TB ONE PLATE 3P MILK WHITE 1 pcs

GW 16 803 SUPPORTS, ITALIAN STD. 3P 1 pcs

GW 24 403 BIGBOX 3-GANG BOX FOR MASONRY WALLS 1 pcs

GW 10 195 BLANKING MODULE 1M WHITE 1 pcs

GW 10 703 FLUSH-MOUNTING TIMED THERMOSTAT 2M 230V AC, WHITE 1 pcs

Code Description Qty Code Description Qty

89

PB 22359 EN Cata prog Light 0316_EN.indd 89 15/04/16 11:51

Page 89: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

LIGHTING2015

TRADE CATALOGUEGEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - ItalyTel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) 00385040167 - REA 107496 - Share Capital 60,000,000.00 EUR fully paid up

TRA

DE

CATA

LOG

UE

201

5 LI

GH

TIN

G

PB 1

1086

EN

- 05

.15

Copertina Lighting 2015_EN.indd 1 04/05/15 17:51

TRA

DE

CATA

LOG

UE

201

5 BU

ILD

ING

BUILDING2015

TRADE CATALOGUEGEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - ItalyTel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) 00385040167 - REA 107496 - Share Capital 60,000,000.00 EUR fully paid up PB 1

1085

EN

- 05

.15

Copertina Building 2015_EN.indd 1 04/05/15 17:51

POWER2015

TRADE CATALOGUEGEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - ItalyTel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) 00385040167 - REA 107496 - Share Capital 60,000,000.00 EUR fully paid up

TRA

DE

CATA

LOG

UE

201

5 PO

WER

PB 1

1084

EN

- 05

.15

Copertina Power 2015_EN.indd 1 04/05/15 17:52

TRA

DE

CATA

LOG

UE

201

5 D

OM

OTI

CS

TRADE CATALOGUE

DOMOTICS2015

GEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - ItalyTel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) 00385040167 - REA 107496 - Share Capital 60,000,000.00 EUR fully paid up PB 1

1083

EN

- 05

.15

Copertina Domotics 2015_EN.indd 1 04/05/15 17:51

Smart [3] WATERTIGHT LEDLUMINAIRE

NEW

Quartino_Smart3_EN.indd 2 08/02/16 09:01

Road [5] LED DEVICES FOR STREET AND URBAN LIGHTING

INNOVATIONS

Smart [3] Road [5]

Lighting Catalogue Building Catalogue Power Catalogue Domotics Catalogue

Street [03] Urban [03] Astrid RangeSmart [4]

90

Commercial documentation

PB 22359 EN Cata prog Light 0316_EN.indd 90 15/04/16 11:51

Page 90: PB 22359 EN - 03 - Gewiss 22359 EN Cata prog Light 0316_EN.indd 10 15/04/16 11:44. ... Id 4 5 20 Id 18 19 Id 16 17 Id 14 15 Id 12 13 Id 10 11 Id 8 9 Id 6 7 Id NEUTRO FASE P1 Kpp1 P2

SOLUTIONS FOR

sport facilities lighting2nd EDITION

PB 2

2359

EN

- 03

.16

GEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - Italy Tel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com

Sole Shareholder company - Bergamo Register of Companies / VAT / Tax code (IT) 00385040167 - REA 107496 - Share capital 60,000,000.00 EUR fully paid up

PB 22359 EN Cover dorso 0316.indd 1-3 15/04/16 09:31