pcb : detoxification of building materials in dk presentation for eurits d. 14 may 2012
DESCRIPTION
PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012 Lars Gunnarsen Danish Building Research Institute , Aalborg University. Polychlorinated biphenyl. PCB fundamentals. Sum 7 congeners: 28, 52, 101, 118 , 138, 153 og 180 - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/1.jpg)
PCB: Detoxification of buildingmaterials in DK Presentation for EURITS d. 14 May 2012
Lars GunnarsenDanish Building Research Institute, Aalborg University
![Page 2: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/2.jpg)
Polychlorinated biphenyl
![Page 3: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/3.jpg)
Sum 7 congeners: 28, 52, 101, 118, 138, 153 og 180
2 dioxin-like congeners: 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, og 189
All PCB congeners akkumulate in human bodies
105 og 118 has WHO TEF på 0,0001 and for 156 it is 5 times biggerHighest TEF has nr. 126 with TEF equal 0,1
Vapor pressure of PCB 118 at 25 C is 8.974 × 10–6 mmHg = 0.001196 Pa = 1.18 × 10-8 atm. In air at 1,013 × 105 Pa (1 atm) this is equal to 12 ppb or 160 µg/m3
Occupational TLV is 0 µg/m3
The national Board of Health reccomends action limits set at 3 and 0,3 µg/m3 for indoor air
PCB fundamentals
![Page 4: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/4.jpg)
Construction products
Indoor air
Surface Dust
Soil
![Page 5: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/5.jpg)
0
5
10
15
20
25
30
35
40
45
50
Opførelsesår
Byg
ning
sbes
tand
(m
io m
2)
Erection Year
Bui
ldin
g ar
ea
![Page 6: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/6.jpg)
1950 to 1976 where PCB containing sealant were on the marked 143 mill. m2 new buildings have been erected which is 37 % of the total building stock of 389 mill. m2.
Have not got new windows since 1976 61 %Have rubber-like inner sealants 59 %Have rubber-like outer sealants 22 %Length inner sealants per area 0,47 m/m2
Length inner sealants per area 0,47 m/m2
Total remaining PCB in construction products 20 x103 kgMass primary PCB sources 6.6x106 kgMass secondary sources 3.4x109 kg
Some inofficial guestimates
![Page 7: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/7.jpg)
10 15 20 25 30 35 40 45 50 55 600
0.1
0.2
0.3
0.4
0.5
0.6
0.7
PCB 28
Temperature (oC)
Vapo
r pre
ssur
e (P
a)
EKSP(34,92 - 11,624*1000/(t + 273))
Temperature dependency of vapor pressure
Equation valid 40-55 oC
![Page 8: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/8.jpg)
> 50 mg PCB/kg Dangerous waste To be destructed at approved inceneration plant or deposited underground (not possible in Denmark)
0,1 – 50 mg PCB/kg Not dangerous waste
•Waste with PCB content of less than 1 mg/kg may be deposited at depot for inert waste
•Waste with PCB content between 1 and 50 mg/kg, may be deposited at depot for for mineral waste or mixed waste
< 0,1 mg PCB/kg Products for reuse
May be reused according to other specific rules after notification of municipal authorities
![Page 9: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/9.jpg)
Action values for building occupancy.
> 3.000 ng PCB/m3 air Highest level. Immediate action required.Durable sollutions - could be evacuation of building - should take place before 6 months.
300 – 3.000 ng PCB/m3 air Intermediate level. An action plan required to after some time assure indoor air concentrations below 300 ng PCB/m3 luft.
At 2.000 – 3.000 ng PCB/m3 it is recommended that a maximum of one year may pas before a durable solution is commenced.
At 300 – 2.000 ng PCB/m3 it is recommended that a maximum of two years may pas before a durable solution is commenced. Temporary alleviation measures should be considered.
< 300 ng PCB/m3 air Lowest level that does not increase the health risks.
PCB exposure from indoor air and health risks in relation to recommendations from National Board of Health
Recommendations are based on occupancy of buildings 24-7 for several years.
![Page 10: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/10.jpg)
![Page 11: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/11.jpg)
Homepage ofthe project
SBi.dk/pcb
(in Danish)
![Page 12: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/12.jpg)
Projekt planning 1. år 2. år 3. år 4. år F1. Planning
Litterature survey F2. Laboratory tests
Field tests Data analysis
F3. PCB instruction guide Field tests Data analysis
F5. Improved guide
![Page 13: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/13.jpg)
Recent measurements
24 congeners included in the analysis: PCB-28, 52, 66, 74, 77, 81, 99, 101, 105, 114, 118, 123, 126, 138, 153, 156, 157, 167, 169, 170, 180, 183, 187 og 189. (Dioxin-like in red)
Blood samples furthermore included congener number 69, 178, 182 og 190.
![Page 14: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/14.jpg)
Sample summary
• Results from:– 83 air samples (Birkhøj)– 20 sealant samples (Birkhøj)– 21 air samples (uncontaminated parts of Farum
Midtpunkt)– Approx. 200 blood samples 100 from
contaminated and 100 from PCB free appartments
![Page 15: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/15.jpg)
Sealant samples were taken by knife for single use after removal of temporary sealing with aluminum tape and wodden panels.
![Page 16: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/16.jpg)
Air samples were taken by adsorption on XAD-2 and a total sampling volume during approx. 24 hours of approx. 2.7 m3.
![Page 17: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/17.jpg)
Results, airBirkhøj (n=83), PCBtot
• Average: 1030 ng/m3
• Interval: 168-3843 ng/m3
• 80 appa. > 300 ng/m3 ; 8 appa. > 2000 ng/m3 ; 1 appa. >3000 ng/m3
Øvrige (n=21),• PCB > LOQ in 52%• Average = 6.0 ng/m3 ; interval <LOQ – 254 ng/m3
• OBS! one appartment with high PCB-level. The occupant had lived 31 years in contaminated part and indoor air contamination from household contents suspoected.
![Page 18: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/18.jpg)
Resultats, sealants• Average ∑24PCB: 100 817 mg/kg (187 – 221 667 mg/kg)
• Average PCBtot: 252 150 mg/kg (436 – 718 430 mg/kg)
PC 1 (76%)
PC
2 (2
3%)
-10 -5 0 5-4
-2
0
2
4
6
401A
406C
410D 410E
410F
413D
414E414F
422E
427A
433C434D 435A435D
439E
444F446D448A
456A456F
Ar-1232
Ar-1242
Ar-1254
Group A
Group B
Group C
Group D
![Page 19: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/19.jpg)
Air vs. selants
• Good correlation for low-chlorinated (even intercorrelation)• No correlation between air and sealants for highly-chlorinated
PCB-28 in air and sealant
PCB-28 in air (ng/m3)
PC
B-2
8 in
sea
lant
(m
g/kg
)
10 100 100010
100
1000
10000
PCB-52 in air and sealant
PCB-52 in air (ng/m3)
PC
B-5
2 in
sea
lant
(m
g/kg
)
10 100 100010
100
1000
10000
100000
![Page 20: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/20.jpg)
Sum of 24 measured congeners in indoor air (ng/m3)
![Page 21: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/21.jpg)
Sum of 12 non-dioxinlike congeners in indoor air (ng/m3)
![Page 22: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/22.jpg)
Sum of 12 dioxinlike congeners in indoor air (ng/m3)
![Page 23: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/23.jpg)
139134N =
127165103219
201
240
241
7525041273793
9435
PCB
118
in pl
asm
a, u
g/l
,7
,6
,5
,4
,3
,2
,1
0,0
-,1
PCB exposure in apartment
ExposeNon-exposed
![Page 24: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/24.jpg)
Number of years living in Farum Midtpunkt dwelling
4035302520151050-5
Sum
of 3
- 4
chlo
rine
PCB
in p
lasm
a, u
g/l
25
20
15
10
5
0
-5
PCB exposure
Exposed
Non-exposed
Correlation coefficient 0.69 ; p<0.001 (Spearman); n = 154
PCB 28 in air of dwelling, ng/m3
3002001000
PCB
28 in
pla
sma,
ug/
l
12
10
8
6
4
2
0
![Page 25: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/25.jpg)
PCB congener
Number Concentration, mg/kgAverage Min 25 percentile Median 75 percentile Max
Sum 24 20 100817,4 187,0 4556,5 101040,0 168584,8 221677,0
Sum_DL 19 13472,3 29,4 1071,7 15836,8 22370,7 26382,3
Sum_NDL 20 87274,4 157,5 3465,9 80113,3 152273,9 206043,0
Total PCB (6) 20 252149,7 436,0 7005,2 165207,5 500091,3 718430,0
Total PCB (6+1) 20 283017,0 511,6 9678,8 210992,5 538203,8 749330,0
PCB content in selants in contaminated part
![Page 26: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/26.jpg)
PCB congener
Concentration, ng/m3
Average Min 25 percentile Median 75 percentile Max
Sum 24 284,90 43,31 150,13 235,77 350,57 1060,02
Sum_DL1 3,21 0,18 1,20 2,19 3,53 16,53
Sum_NDL2 281,68 43,10 146,96 233,73 349,21 1043,48
Total PCB (6) 1030,15 167,97 531,21 858,75 1333,83 3842,88
Total PCB (6+1)
1038,90 167,95 534,55 861,95 1343,75 3888,30
PCB in indoor air in contaminated part
![Page 27: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/27.jpg)
Questionnaire resultsa) Vacuuming
PCB
tot,
air
(ng/
m3)
Daily Weekly Monthly Less0
500
1000
1500
2000
(n=9) (n=1)(n=10)(n=61)
b) Dusting
PCB
tot,
air
(ng/
m3 )
Daily Weekly Monthly Less0
500
1000
1500
2000
*
(n=3) (n=2)(n=19)(n=57)
c) Floor washing
PC
Bto
t, a
ir (n
g/m
3 )
Daily Weekly Monthly Less0
500
1000
1500
2000
(n=2) (n=8)(n=29)(n=41)
d) AiringP
CB
tot,
air
(ng/
m3 )
Daily Weekly Monthly Less0
500
1000
1500
2000
(n=54) (n=3)(n=5)(n=21)
![Page 28: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/28.jpg)
Cleaning does help
![Page 29: PCB : Detoxification of building materials in DK Presentation for EURITS d. 14 May 2012](https://reader036.vdocument.in/reader036/viewer/2022062410/56816471550346895dd6555b/html5/thumbnails/29.jpg)
Conclusions
There still is PCB in some buildings – maybe in approximately 10% of the buildings from the relevant period
Old sealants with PCB, will still be a significant source of PCB in indoor air, surface dust and the soil around the buildings. In rare cases this may lead to health risks for the building occupants
PCB in dwellings leads to a significantly increased PCB contamination of building occupants. For these people the dwelling causes by far the most PCB intake
Better ability to identify buildings with PCB is recommended
More efficient means of renovation of PCB contaminated buildings are recommended
More rigorous waste hanling recommended
More reseach, innovation and consistency recommended