pcdc submittal set: not for construction

6
UP UNFINISHED basement UNEXCAVATED rough in plumb. for pROPOSED BATHROOM LOCATION w/h sump FURN. EP UNEXCAVATED cantilever at first floor fd f.p.h.b. f.p.h.b. 2x12 joists at 16" o.c. (2) 2x12 bm. (ijs) (2) 2x12 bm. (ijs) fireplace cantilever (2) 2x12 bm. (ijs) (2) 2x12 bm.(IJS) (2) 2x12 bm.(IJS) SUMP PIT AND PUMP 24" DIA X 24" DEEP MIN W/ DEDICATED OUTLET 4" 2500 PSI CONCRETE SLAB OVER 6 MIL VAPOR BARRIER (LAP JOINTS MIN 6" AND SEAL) OVER MIN 4" GRAVEL OR CRUSHED STONE, maintain a min. finished clearance of 8'-0" ceiling height clearance with beams, ductwork, and all other projections. PORCH ABOVE- 4" 3500 psi concrete slab w/ wwm over gravel fill GARAGE ABOVE- 3500 PSI CONC. SLAB W/ WWF OVER GRAVEL FILL (4" MIN) SLOPE TOWARDS DOOR TYP. GARAGE FND. WALL 8" FOUNDATION WALL W/ (2) #4 HORIZONTAL BARS AT TOP AND BOTTOM TYP. GARAGE STRIP FTG. 24" X 8" W/ (2) #4 REBAR CONT. 24" x 8" ftg. w/ (2) #4 rebar cont. typ. concrete foundation wall 10" fnd wall w/ (2) #5 bars top, middle, and bottom. #6 vertical bars at 56" o.c. 3 span w10 x 26 stl bm. (2) 2 x 12 bm. (ijs) (3) 2 x 12 bm. (ijs) 4x4 post on 24" x 24" x 12" conc. pad unreinf. 3 1/2" dia. adj. 7.58# stl. col over 30" x 30" x 12" conc. pad footing (2) 2 x 12 bm. (ijs) bp bp bp bp 3 1/2" dia. adj. 7.58" stl. col over 30" x 30" x 12" conc. pad footing 2-span w8 x 10 stl bm. hold down t.o. fnd. to rec. garage slab (2) 2x12 BM. (IJS) FLR JOISTS at 12" O.C. AT island abv. (2) 2x12 bm.(IJS) hold down hold down hold down hold down hold down hold down hold down hold down 36' - 0" 2' - 0" 1' - 6" 25' - 0" 7' - 6" 62' - 0" 17' - 6" 44' - 6" 36' - 0" 6' - 0" 30' - 0" 26' - 6" 15' - 6" 20' - 0" 8" 25' - 10" 10" 15' - 4" 10" 17' - 8" 10" 8" 10" 8" 23' - 8" 10" 6' - 6" 10" 8" 10" 9' - 0" 33' - 10" 10" 10" 3' - 6" 14' - 2" 14' - 8" 10" 13' - 7 1/2" 3' - 7" 14' - 6 1/2" 10" 13' - 1" 11' - 0" 6' - 7" 3' - 2" 10" 5' - 0" 2' - 11" 2' - 0" FURN. 62' - 0" 14' - 3" 3 1/2" 5' - 0" 5 1/2" 13' - 10" 54"V 8" 8" 8" 7' - 0" 11' - 6" 11' - 6" 17' - 10" 8" 8" 5' - 4" 10" 2' - 0" 2' - 0" FUTURE BATHROOM (OPT.) 2268 proposed gas line location for grill 5' - 2 1/2" 12' - 6" 14' - 0" 2468 fd field verify max wdw. height w/ grade 3' - 5 1/2" 10' - 6" JDALLC21102 This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC Jeff Day & Associates, LLC Missouri State Certificate of Authority # A-2009027415 CHECKED BY: JKD 14311 Manchester Rd. St. Louis, MO. 63011 314.644.2775 www.jeffdayllc.com ARCHITECTURE & PLANNING & JEFF DAY L L C ASSOCIATES DRAWN BY: TCH REVISED: R1 00.00.00 R2 00.00.00 R3 00.00.00 DATE: 09.21.2021 PCDC REVIEW IN OLIVETTE A1 SOLOMON-JONES OLIVETTE, MO. 63132 9721 HASTINGS DR. SCALE: 1/4" = 1'-0" FOUNDATION PLAN PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Upload: others

Post on 28-Dec-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

UPUNFINISHED basement

UNEXCAVATED

rough in plumb. for pROPOSED BATHROOM LOCATION

w/h

sump

FURN.

EP

UNEXCAVATED

cantilever at first floor

fd

f.p.h.b.

f.p.h.b.

2x12 j

ois

ts

at 16"

o.c

.

(2) 2x

12 b

m. (ijs

) (2) 2x

12 b

m. (ijs

)

fir

epla

ce

cantilever

(2) 2x

12 b

m. (ijs

)

(2) 2x12 bm.(IJS)

(2) 2x12 bm.(IJS)

SUMP PIT AND PUMP 24" DIA X 24" DEEP MIN W/ DEDICATED OUTLET

4" 2500 PSI CONCRETE SLAB OVER 6 MIL VAPOR BARRIER (LAP JOINTS MIN 6" AND SEAL) OVER MIN 4" GRAVEL OR CRUSHED STONE, maintain a min. finished clearance of 8'-0" ceiling height clearance with beams, ductwork, and all other projections.

PORCH ABOVE-4" 3500 psi concrete slab w/ wwm over gravel fill

GARAGE ABOVE-3500 PSI CONC. SLAB W/ WWF OVER GRAVEL FILL (4" MIN) SLOPE TOWARDS DOOR

TYP. GARAGE FND. WALL8" FOUNDATION WALL W/ (2) #4 HORIZONTAL BARS AT TOP AND BOTTOM

TYP. GARAGE STRIP FTG. 24" X 8" W/ (2) #4 REBAR CONT.

24" x 8" ftg. w/ (2) #4 rebar cont.

typ. concrete foundation wall10" fnd wall w/ (2) #5 bars top,

middle, and bottom. #6 vertical bars at 56" o.c.

3 span w10 x 26 stl bm.

(2) 2

x 12

bm

. (ijs

)

(3) 2 x 12 bm. (ijs)

4x4 post on 24" x 24" x 12" conc. pad unreinf.

3 1/2" dia. adj. 7.58# stl. col over 30" x 30" x 12" conc. pad footing

(2) 2

x 12

bm

. (ijs

)

bp

bp

bp

bp

3 1/2" dia. adj. 7.58" stl. col over 30" x 30" x 12" conc. pad footing

2-span w8 x 10 stl bm.

hold down t.o. fnd. to rec. garage slab

(2) 2x12 BM. (IJS)

FLR JOISTS at 12" O.C. AT

island abv. (2) 2x

12 b

m.(IJS)

hold downhold down

hold down

hold down

hold down hold down

hold down

hold down

36' -

0"

2' -

0"1' -

6"

25' -

0"

7' -

6"

62' - 0"

17' - 6" 44' - 6"

36' -

0"

6' -

0"

30

' -

0"

26' - 6" 15' - 6" 20' - 0"

8" 25' - 10" 10" 15' - 4" 10" 17' - 8" 10"

8" 10"

8"

23' -

8"

10"

6' -

6"

10"

8"

10" 9' - 0" 33' - 10" 10"

10"

3' -

6"

14' -

2"14

' -

8"

10"

13' -

7 1/2"

3' -

7"14

' -

6 1/2

"

10" 13' - 1" 11' - 0" 6' - 7" 3' - 2" 10"

5' -

0"

2' -

11" 2' - 0"

FURN.

62' - 0"

14' - 3" 3 1/2" 5' - 0" 5 1/2" 13' - 10"

54"V

8"8"8"

7' -

0"

11' -

6"

11' -

6"

17' - 10" 8"

8"

5' -

4"

10"

2' - 0"

2' -

0"

FUTURE BATHROOM (OPT.)

2268

proposed gas line location for grill

5' - 2 1/2" 12' - 6"

14' -

0"

2468

fd

field verify max wdw. height w/ grade

3' -

5 1/2

"10

' -

6"

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A1

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

SCALE: 1/4" = 1'-0"

FOUNDATION PLAN

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Page 2: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

UP

REF.

RA

NG

EN

.I.C

.

DW

DN

DN

Freezer

DN

DN

STUDY

FAMILY ROOM

DINING ROOM

HEARTH

KITCHEN

GARAGE FOYER

MICRO &

OVENPANTRY MOP PwdR

FRONT PORCH

CLOSETDN

mech chase

30

68t.g

.

1268lite 1268lite

40

68d

bl

2068

2468

2468S.C.

2868

6068sldr

2868s.c

.

9'x7' garage door9'x7' garage door

2868S.C

.

owner provided pocket doors 3'-0" x 6'-8" pair

electric

(2) 2x10 hdr (2) 2x10 hdr

(2) 2x10 hdr

(2) 2x10 hdr (2) 2x10 hdr

(2) 2x

10 h

dr

(2) 2x

10 h

dr

(2) 2x

10 h

dr(2) 2x10 hdr(2) 2x10 hdr

(2) 2x10 hdr

(2) 2x10 hdr

(2) 2x10 hdr

(2) 2x

10 h

dr

(2) 2x

10 h

dr

(2) 2x12 hdr (2) 2x12 hdr

roof t

russes d

.b.o

. at 2

4"

o.c

.

11 1/4

" tji

at 16"

o.c

.

(2) 2x10 bm. (ijs)

roof t

russ d

.b.o

. at 2

4"

o.c

.

slo

pe t

oward

s d

oor

(2) 2x12 bm.

(2) 2x

12 b

m. HOLD DOWN

HOLD DOWN

HOLD DOWN

HOLD DOWN

HOLD DOWN

HOLD DOWN

HOLD DOWN

(2) 2x12 bm

(2) 2x

10 h

dr

tv niche above

4068bipass

7076

c.o

.

sound insulated wall

36' -

0"

2' -

0"

7' -

6"

25' -

0"

1' -

6"

17' - 6" 22' - 11" 11' - 0" 10' - 7" 2' - 0"

36' -

0"

2' -

0"

3' -

9"

5' -

0"

21' -

3"

4' -

0"

2' -

0"

26' - 6" 17' - 0" 18' - 6"

62' - 0"

7' - 11" 10' - 10" 7' - 9" 5' - 0" 7' - 0" 5' - 0" 3' - 6" 6' - 6" 5' - 6" 3' - 0"

2' -

0"

1' -

9"

5' -

0"

1' -

9"

16' -

6"

3' -

0"

5' -

2"2' -

4"

6' -

4"

12' -

4"

6' -

4"

14' - 6" 3' - 0" 16' - 6" 6' - 5" 5' - 6" 5' - 6" 2' - 7" 4' - 6" 3' - 6"

64' - 0"

(2) 2x12 bm.

(2) 2x

12 b

m.

8x8 col w/ wrap verify size with owner

8x8 col w/ wrap verify size with owner

20' - 0"

3 5/8" 8' - 8 3/8" 10' - 8 3/8" 3 5/8"

5' - 0" 15' - 0"2' -

0"

3 1/2" 10' - 5" 6"7' - 6"16' - 0"4" 26' - 2 1/2"

2' - 1"3' - 7"3 1/2" 4' - 2"

2' -

1"

5 1/2

"11' -

6"

6"

11' -

6"

6"

2' -

10

1/2

"

2' - 1" 5' - 5"

6" 3' - 3" 5' - 2" 13' - 7 1/2" 10' - 0" 10' - 7"

5 1/2"

1' - 8 1/2"

4"

5' - 5" 11" 9' - 9 1/2"3' - 0"5' - 8"2' - 7"5 1/2" 5' - 2" 9 1/2"

14' -

0"

6"

3' -

7"2' -

1 1/2

"12' -

8 1/2

"6"

10' -

4 1/2

"2' -

4"

2' -

0"6

"

1' -

9 1/4

"

1' -

10"

3' -

7"10

' -

0"

10' - 10"5' - 2"

24' -

4"

4"

4' -

8"

2' -

1"

30

68co

2' -

1"

3' -

0 1/2

"

GAS FIREPLACE W/ DIRECT VENT AS SELECTED BY OWNER. COORD ALL DIMS WITH SELECTED PRODUCT

30"V

COORD WDW WITH CABS SELECTED

FINAL D.B.O.

COORD. FINAL DIMS W/ PRODUCT SELECTED by owner

HVAC VENT AT TOE KICK D.B.O.

SOLDERED COPPER PIPES FOR ALL KITCHEN wATER SUPPLY D.B.O.

COMPOSITE JAMB AT REAR DOOR

bwp

4' -

0"

bwp

4' - 0"

bwp

4' -

0"

bwp

4' -

0"

trash can location

18' - 8" 20' - 0" 5' - 10"

+/-1

5'-0

"

7' - 5 7/8"

13' -

0"

f.v. w/ owner for length of wall at fridge.

slant floor joist above stair opening

thermal insulate mech chase walls if trunk line isnt insulated

patio

patio

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A2

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

SCALE: 1/4" = 1'-0"

FIRST FLOOR

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Page 3: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

MASTER BEDROOM

MASTER BATH

CLOSET

LAUNDRY

HALL

BEDROOM 2

BEDROOM 3BATH

LINEN

CLOSET

HELLCAT HIDEAWAY

W.I.C.

ROOF BELOW

ROOF BELOW

DN

opt. coffered ceiling

ROOF BELOW

mech

20682468

2668

26682668

2668

2668S.C

.

5068bipass

5068bipass

2668

2668

2468tg

2468

wash

gas

dr

y

(2) 2x10 hdr (2) 2x10 hdr

(2) 2x10 hdr (2) 2x10 hdr (2) 2x10 hdr

(2) 2x

10 h

dr

(2) 2x

10 h

dr(2) 2x10 hdr

(2) 2x10 hdr

(2) 2x

10 h

dr

(2) 2x

10 h

dr

girder truss

roof b

elo

w

sound insulated wall

(2) 2x10 hdr

47' - 0"

35' - 6"

34' -

0"30

' -

0"

4' -

0"

35' - 6"11' - 6"

34' -

0"

1' -

6"

16' -

10"

15' -

8"

5' - 6" 13' - 6" 12' - 8" 3' - 10"

DORMER

7' - 6" 4' - 0"

3' - 9" 3' - 9" 4' - 0" 5' - 0" 7' - 0" 5' - 0" 3' - 6" 6' - 6" 5' - 6" 3' - 0"

2' -

6"

17' -

0"

10' -

6"

7' -

11"

7' -

9"

12' - 0"

6"

6" 11' - 0 1/2" 5 1/2" 22' - 2 1/2"

5' - 11"16' - 0"

6' - 6" 4' - 6 1/2"

14' -

0"

6"

15' -

0"

3' -

5"

3' -

7"3' -

7"5 1/2

"7' -

1"

6"

15' -

10"

6"

7' -

7"

8' -

2 7/

8"

7' -

9"

2668

92"V

(2) 2x10 hdr

7' - 2 1/2" 3' - 6" 8" 5' - 1" 3' - 1" 1' - 11 1/2"

7' -

9"

6' -

9 1/2

"3' -

7"

78"V

8' -

10"

6"

10' -

0"

3' -

0"

3' - 6 1/2" 3' - 6" 2' - 3" 5 1/2"

7' - 0" 5' - 2" 5 1/2" 11' - 10"

5' - 8 1/2" 6' - 0"

11' -

8"

2' -

1"

14' -

8"

2' -

1"

2' -

1"

3' - 4" 6' - 0" 2' - 1"

12' -

3 1/2

"

5 1/2"

6' - 10"9' - 11"

30"V

11' - 10" 6"

sound insulate double wall

6"

6' -

9 1/2

"

lin

en

1' - 8" 3' - 6"

2' -

6 1/2

"6' -

9"

3' - 8"

thermal insulate mech chase walls if trunk line isnt insulated

8' -

7"

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A3

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

SCALE: 1/4" = 1'-0"

SECOND FLOOR

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Page 4: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

FIRST FLOOR

T.O. PL.

T.O. FND.

T.O. SLAB

SECOND FLOOR

t.o. pl.

36X72s.h.

36X72s.h.

32X72S.h.

32X72s.h.

tg

tg

tg

36X62D.H.

36X62D.H.

24X42FXD

32X62 D.H.

32X62D.H.

WD

W H

EIG

HT

7' -

0"

WD

W H

EIG

HT

6' -

10"

GARAGE FOUNDATION

basement FOUNDATION

porch foundation

9' -

1 1/8"

8' -

1 1/8"

8' -

6"

step

step

4"

1'-0"

9"

1'-0"

8"

1'-0"

4"

1'-0"T.O. GAR. PL.

cont. ridge vent

cont. ridge vent

8' -

1 1/8"

O.H.

1' - 0"

min

.

4"wall flashing

exterior shingle siding as selected by owner (typ.)

1x8 fascia brd. (typ.)

10" trim board

gutter as selected by owner (typ.)

4" window trim (typ.)

asphalt shingle roof as selected by owner (typ.)

4" corner trim (typ.)

8"

1'-0"8"

1'-0"

8"

min

32x62d.h.

32x62d.h.

6" trim

o.h.

9"

o.h.

9"

lap siding as selected by owner (typ.)

o.h.

1' - 0"

o.h.

1' - 0"

o.h.

1' - 0"

o.h.

4"

8x8 post w/ wrap (typ.)

FIRST FLOOR

T.O. PL.

T.O. FND.

T.O. SLAB

SECOND FLOOR

t.o. pl.

9' -

1 1/8"

36X72s.h.

36X72s.h.

GARAGE FOUNDATION

basement fOUNDATION

42x36fxd tg

8' -

1 1/8"

8' -

6"

4" 1'-0"4"

1'-0"

T.O. GAR. PL.

cont. ridge vent

wd

w. heig

ht

6' -

10"

O.H.

1' - 1"

O.H.

3' - 0"O.H.

1' - 0"

O.H.

1' - 0"

WALL FLASHING

WALL

FLA

SHING

WALL FLASHING

30X48S.H.

wd

w h

eig

ht

7' -

0"

min4"

8"

min

min

4"

min

4"

o.h.

1' - 0"

o.h.

1' - 0"

asphalt roof shingles as selected by owner (typ.)

4" corner trim (typ.)

shingle siding as selected by owner (typ.)

gutter as selected by owner (typ.)

lap siding as selected by owner (typ.)

4" window trim (typ.)

8x8 post w/ wrap (see plan)

6" concrete patio slab

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A4

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

SCALE: 1/4" = 1'-0"

FRONT ELEVATION

SCALE: 1/4" = 1'-0"

LEFT ELEVATION

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Page 5: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

FIRST FLOOR

T.O. PL.

T.O. FND.

T.O. SLAB

SECOND FLOOR

t.o. pl.

28X72s.h.

28X72s.h.

42X36sldr.

36X62d.h.

30X44d.h.

TG TG

WD

W H

EIG

HT

7' -

0"

24X24fxd

GARAGE FOUNDATION

basement FOUNDATION

8' -

6"

9' -

1 1/8"

8' -

1 1/8"

8"

1'-0"

8"

1'-0"

9"

1'-0"

4"

1'-0"

T.O. GAR. PL.

cont. ridge vent

cont. ridge vent

wd

w. heig

ht

6' -

10"

O.H.

1' - 0"

o.h.

1' - 0"

WALL FLASHING

MIN4"

o.h.

1' - 0"

o.h.

1' - 0"o.h.

4"

o.h.

4"

o.h.

4"

roof shingles as selected by owner (typ.)

corner trim (typ.)

window trim (typ.)

gutter as selected by owner (typ.)

lap siding as selected by owner (typ.)

FIRST FLOOR

T.O. PL.

T.O. FND.

T.O. SLAB

SECOND FLOOR

t.o. pl.

32X72s.h.

20X72FXD

20X72FXD

36X62D.H.

36X62D.H.

WD

W H

EIG

HT

7' -

0"

WD

W H

EIG

HT

6' -

10"

egress wdw well

basement FOUNDATION

8' -

6"

9' -

1 1/8"

8' -

1 1/8"

4"

1'-0"4"

1'-0"

cont. ridge vent

o.h.

1' - 0"

direct side fireplace vent install per mnf.

MIN

4"

WALL FLASHING

WALL FLASHING

MIN4"

36x24 48x36egress sldr

operable wdw as selected by owner. coord. final wdw. height with exterior grade

o.h

3"o.h.

7' - 0"

o.h.

1' - 0"

o.h.

1' - 0"

o.h.

3"

roof shingles as selected by owner (typ.)

window trim (typ.)

corner trim (typ.)

gutter as selected by owner (typ.)

lap siding as selected by owner (typ.)

shingle siding as selected by owner (typ.)

8x8 post w/ wrap (see plan)

6" concrete patio

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A5

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

SCALE: 1/4" = 1'-0"

REAR ELEVATION

SCALE: 1/4" = 1'-0"

RIGHT ELEVATION

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

Page 6: PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

JDALLC21102This drawing and the details on it are the sole property of the Architect and may be used for this specific project only. it shall not be loaned, copied, or reproduced in whole or in part, or for any other purpose or project without the written consent of the Architect. Copyright 2021 Jeff Day & Associates, LLC

Jeff Day & Associates, LLCMissouri State

Certificate of Authority# A-2009027415

CHECKED BY: JKD

1431

1 M

anch

este

r R

d.

St.

Loui

s, M

O. 6

3011

314.

644.

2775

www.

jeffd

ayllc

.com

ARC

HITE

CTU

RE

& P

LANN

ING

&JEFF

DAY

L L CAS

SO

CIA

TES

DRAWN BY: TCH

REVISED:R1 00.00.00R2 00.00.00R3 00.00.00

DATE: 09.21.2021

PC

DC

REV

IEW

IN O

LIVE

TTE

A6

SO

LOM

ON-

JONE

S

OLI

VETT

E, M

O. 6

3132

9721

HAS

TING

S D

R.

PCDC SUBMITTAL SET: NOT FOR CONSTRUCTION

LEFT OF RESIDENCE RIGHT OF RESIDENCEPROPOSED RESIDENCE