Pacemakers Sorin

TRANSCRIPT

Sheet1Pacemaker type VVIRDDDRVVIR PRENIUMDDDR PRENIUMVVIR PRENIUM 2DDDR PRENIUM 2VVIR - Pro MRIDDDR - Pro MRIModel numberModel nameESPRIT SRESPRIT DRREPLY SRREPLY DRREPLY 200 SRREPLY 200 DRKORA 100 SRKORA 100 DRLongevity9.8 years (70 bpm, 2.5 v, 0.5 ms, 500 ohms, Holter ON, Sensor ON)9 years (70 bpm, 2.5 v, 0.5 ms, 500 ohms, 100% Atrial pacing and 15% Ventricular pacing, diagnostic ON)11.4 years (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% pacing EGM and diagnostic ON)9.6 years in DDDR mode (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% A&V pacing EGM and Diagnostic ON) 12 years in SafeR mode (60 bpm, 2.5 v, 0.35 ms, 50% A pacing, 5% V pacing, 750 ohms, EGM and diagnostic ON)11.4 years (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% pacing EGM and diagnostic ON)9.6 years in DDDR mode (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% A&V pacing EGM and Diagnostic ON) 12 years in SafeR mode (60 bpm, 2.5 v, 0.35 ms, 50% A pacing, 5% V pacing, 750 ohms, EGM and diagnostic ON)11.4 years (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% pacing EGM and diagnostic ON)9.6 years in DDDR mode (60 bpm, 2.5 v, 0.35 ms, 750 ohms, 100% A&V pacing EGM and Diagnostic ON) 12 years in SafeR mode (60 bpm, 2.5 v, 0.35 ms, 50% A pacing, 5% V pacing, 750 ohms, EGM and diagnostic ON)Size7.5 cc, 19 g8 cc, 20 g7.5 cc, 19 g8 cc, 20 g7.5 cc, 19 g8 cc, 20 g7.5 cc, 19 g8 cc, 20 gSafe R mode AAI DDDAAI DDDAAI DDDCap confirmationminimum ventricular amplitudeminimum ventricular amplitudeminimum ventricular amplitudeminimum ventricular amplitudeminimum ventricular amplitudeminimum ventricular amplitudeminimum ventricular amplitude Auto thresholdauto- monitor - offauto - monitor - offauto - monitor - offauto - monitor - offauto - monitor - offauto - monitor - offauto - monitor - offauto - monitor - offAuto lead impedance measurementevery 6 hoursevery 6 hoursevery 6 hoursevery 6 hoursevery 6 hoursevery 6 hoursevery 6 hoursevery 6 hoursStored iEGM14 stored episodes with markers and EGM, up to 3.5 min A+V7 stored episodes with markers and EGM, 1.6 min A or V22 stored episodes with markers and EGM, 5.5 min, A+V7 stored episodes with markers and EGM, 1.6 min A or V22 stored episodes with markers and EGM, 5.5 min, A+V7 stored episodes with markers and EGM, 1.6 min A or V22 stored episodes with markers and EGM, 5.5 min, A+VECG triggersAtrial and Ventricular burst, Mode switchingAtrial and Ventricular burstMode switching, Atrial bursts, Ventricular bursts, Switches in SafeR mode (AV Bloks)Atrial and Ventricular burstMode switching, Atrial bursts, Ventricular bursts, Switches in SafeR mode (AV Bloks)Atrial and Ventricular burstMode switching, Atrial bursts, Ventricular bursts, Switches in SafeR mode (AV Bloks)Rate responseaccelerometer sensor (G)accelerometer sensor (G)Minute ventilation (MV) and Accelerometer (G) MV+G / MV / GMinute ventilation (MV) and Accelerometer (G) MV+G / MV / GMinute ventilation (MV) and Accelerometer (G) MV+G / MV / GMinute ventilation (MV) and Accelerometer (G) MV+G / MV / GMinute ventilation (MV) and Accelerometer (G) MV+G / MV / GMinute ventilation (MV) and Accelerometer (G) MV+G / MV / GMRI compatible nonononononoAutomatic MRI modeAutomatic MRI modePacing configurationunipolar - bipolarunipolar - bipolarunipolar - bipolarunipolar - bipolarunipolar - bipolarunipolar - bipolarunipolar - bipolarunipolar - bipolarAuto implantationAuto measure of lead impedance and configuration programming Auto measure of lead impedance. SafeR mode and configuration programming Auto measure of lead impedance and configuration programming Auto measure of lead impedance. SafeR mode and configuration programming Auto measure of lead impedance and configuration programming Auto measure of lead impedance. SafeR mode and configuration programming Auto sensitivity auto- monitor auto- monitor auto- monitor auto- monitor auto- monitor auto- monitor auto- monitor auto- monitor AV hysteresisDplus DplusDplusDplusAtrial arrhythmia preventionOverdrive, Pause suppression, PAC acceleration Overdrive, Pause suppression, PAC acceleration Overdrive, Pause suppression, PAC acceleration Dynamic AV delayrest, exercise, auto reprogramming for PMT protectionrest, exercise, auto reprogramming for PMT protectionrest, exercise, auto reprogramming for PMT protectionrest, exercise, auto reprogramming for PMT protectionRest ratebased on physical activitybased on physical activitybased on physical activitybased on physical activitybased on physical activitybased on physical activitybased on physical activitySudden rate dropsmoothing smoothingsmoothingsmoothing, accelerationsmoothingsmoothing, accelerationsmoothingsmoothing, accelerationSleep Apnea Monitoring (SAM)Monitoring on-off, monitoring period choice . Respiratory disturbance index; number and duration of events in diagnosticsMonitoring on-off, monitoring period choice . Respiratory disturbance index; number and duration of events in diagnosticsMonitoring on-off, monitoring period choice . Respiratory disturbance index; number and duration of events in diagnosticsMonitoring on-off, monitoring period choice . Respiratory disturbance index; number and duration of events in diagnosticsRate HysteresisYesYesYesYesYesYesYesYesTest assistant smartcheckNoNoYesYesYesYesYesYesRegulatory Status" " " " " " " "