access control pac overview - stanley security …stanleypac.com/products/resource...
TRANSCRIPT
Access Control | 512 Two-Door Controller Series
Overview
The PAC 512 and the PAC 512IP control all aspects of two secure doors, with up to two card readers installed as entry and exit readers on each door. This includessupport for a door strike to lock and unlock the door and a door contact to detect the doors position. Each door also has a programmable auxiliary input that may beused for alarm system integration, and an auxiliary output that enables a buzzer or strobe when security is breached or a door is left open. A tamper input enables themonitoring of a enclosure door, and an override input that will release both doors. In the event of communication loss, the PAC 512 allows all local functionality tocontinue until the server connection is restored.
With unprecedented scalability and flexibility, a Stanley PAC access control system can consist of just PAC 512-series access controllers, or PAC 512s managed by anAccess and Alarm Server (PAC 500). When operating in conjunction with a PAC 500, the PAC 512 serves as part of an integrated solution that can include both input(PAC 520) and output (PAC 530) controllers, elevator control and sophisticated anti-passback capabilities providing a scalable solution for even the largest applications.
The Readykey™ Controller Retrofit Kit enables the conversion of existing K2100/K2200 controllers installed since 1990, to the new PAC 512 series.Utilizing the existing enclosure and power supply, the kit replaces the legacy controller with new PAC512s. The kit preserves all the existing infrastructure investmentand maximizes the value of existing equipment by maintaining the power supply, cabling, readers and without re-enrolling cardholders.
Key Features
Controls up to two doors
Each door supports up to two K2000 Series/K3000-Series/Oneprox TM readers for entry and exit or one Wiegand reader
Up to 20,000 onboard cardholder database and 16,000 event buffer
75,000 dynamic cardholder management support in conjunction PAC 500
20 system holidays with 20 start and stop dates and times
200 time profiles with up to 4,000 weekly periods
5,000 access groups, each with 2 time profiles and 2 area lists
One Form-C 3-Amp lock relay lock control per door
One programmable supervised or non-supervised Form-C 5-Amp auxillary relay per door*
One programmable supervised or non-supervised ancillary input per door*
Dedicated case tamper and door override to open all doors
Request to exit programmable supervised or non-supervised input per door
Door contact programmable supervised or non-supervised input per door
5V and 12V reader data
PAC 512IP includes a built-in RJ-45 100Mbps Ethernet connection
Local anti-passback
Area anti-passback and area usage in conjunction with PAC 500
Mantrap capability in conjunction with PAC 500
One-TouchTM installation test mode. This installer test facility enables the functionalityof each controller and its associated circuits to be tested locally at the door, by simplypressing a single button without the need for a PC or programming
AC and battery status are monitored and reported
Non-volatile memory storage
Rechargeable lithium battery monitoring and status reporting
Lock sharing across door channels
Individual extended door access times (ADA compliance)
Downloadable firmware updates
DIN-Rail mounting for ease of installation (removable)
*Can be independantly controlled in conjunction with PAC 500 Access & Alarm Server
7S-512IPB
Visit us at...www.stanleypac.com
READYKEY™
COMPATIBLE
Visit us at...© 2018 Stanley Security Solutions, Inc. All Rights Reserved. All trademarks are the property of their respective owners.512 2018/1
CONTROLLER AND OPTIONS
7S-512 Stanley PAC 512 - Two Door Access Controller (DIN-Rail Mount)7S-512B STANLEY PAC 512 - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock ,
prewired with a single output 3A power supply/charger,12 or 24VDC selectable.
7S-512IP Stanley PAC 512IP - Two Door Access Controller (DIN-Rail Mount)7S-512IPB Stanley PAC 512IP - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock ,
prewired with a single output 3A power supply/charger,12 or 24VDC selectable.
7S-2KRETRO Readykey K2100/K2200 Controller Retrofit Kit
7S-PSU3 Stanley 3A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)7S-PSU7 Stanley 7A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)
SPECIFICATIONS
Primary Power The PAC 512 is for use in low voltage, power limited, class 2 circuits onlyInput Power: 10.5VDC to 28VDC — PAC 512IP 220mA maximum, PAC 512 220mA maximum
Event Memory and Clock Backup 3V Rechargeable Lithium Cell (Monitored and status reported) - 6 months memory retention when not poweredCommunication Ports
Ethernet (PAC 512IP only): 10/100Base-T Ethernet high-speed RJ-45 portDial-Up (PAC 512 only): RS-232Downstream Ports: RS-485, 32 local devices maximum
InputsTamper and Door Override: Programmable as supervised or unsupervised circuits, dedicatedPower Fail Monitors (MSTAT): Unsupervised, dedicated
Door Configuration Each door supports up to two K2000 Series/K3000-Series/Oneprox TM readers for entry and exit or one Wiegand reader Inputs Per Door
Door Contact, REX & Auxiliary Input: Each programmable as normally open,or normally closed, supervised or unsupervised circuitsOutputs Per Door
Relay outputs: One Form-C 3 A at 30VDC relay for lock control with thermal fuse and one programmable Form-C 5 A at 30VDC auxiliary relayReader Power Follows input voltage. Limited to 200 mA @ 12 VDCReader Port Compatibility PAC, Wiegand Data 1/Data 0 and Magstripe Clock/DataStatus LEDs RS-232, RS-485, Door 1, Door 2, LAN Status and System StatusWiring Requirements RS-485: CAT5 or CAT 6 up to 3000ft or 22AWG cable up to 500ft total cable.
Reader Wire: 22AWG Unshielded and Stranded, up to 800 ftMechanical
DIN-Rail Unit Dimensions: H: 7.3" W: 5.1" D: 5.1"DIN-Rail Unit Weight: 14oz. nominalEnclosure Dimensions: H: 13" W: 13" D: 3.5"
EnvironmentalTemperature: Operating: 14F to 130°F Storage: 9F to 176F Humidity: 0 to 90% RHNC
Approvals: UL 294-listed, CE-marked and ROHS compliantWarranty 5-Year Limited Warranty
REQUEST-TO-EXIT
+-12 OR 24V BATTERY INPUT
INPUT: 10.5VDC TO 28VDCDOOR LOCK
DOOR CONTACT
DOOR LOCK
DOOR CONTACT
EXIT (OUT) READEROR REX BUTTON
AUXILLARY OUTPUT(1 PER DOOR CHANNEL)
AUXILLARY INPUT(1 PER DOOR CHANNEL)
ENTRY (IN) READERENTRY READER
DOOR ONE DOOR TWO
UPSTREAM COMMUNICATIONS:RS-232 (PAC 512), TCP/IP (PAC 512IP)
or RS-485 (PAC 500)
DOWNSTREAM COMMUNICATIONS:TOTAL OF 24 CONTROLLERS
DOOR OVERRIDE
INPUTCASETAMPERINPUT
GROUND
PSU
-+ LOCK POWER OUTPUT
STANLEY PAC 512IP
1 2 3
* 0 #
7 8 9
4 5 6
ENTRYEXIT ENTRY EXIT
PAC
512
IP M
k. II