W·B67A TEST, ENGINEERING AND RESEARCH GROUP, SAN BERNARDINO Our ob No. T56261 Contract Your P.O. No. 4500001654 Date November 19, 2008 This report contains te and correct data. obtained in the perance of the test prog set rth in your purchase order. Test methods, results, ✁d equipmet used are recorded on these data sheets. Where applicle, instru+entatio+ nsed in obtaiing this data has been cabrated using standds which are traceable to the National Institute Standards a Tecolo. SUMMA: One (1) Toolbox, P No. 0450 d idenfied s Wl, was sected to Iersion Testing accordance with MIL-STD-810F, Parah 512$. One {1) Toolbox, Part No. 0450 and idified as W2, was sected to Blowing Dust Testing n accordance with MIL-STD-Kl OF, Pah 510.4. Colete test d?s, clu ps and ient list, test results e coed in this report. Test Dates: 11/17/08-11/18/08 STEOFCALIFORNIA COUNTY OF SAN BERNARDINO }ss; Douglas G. Anderson bei11g . . duly swom, depos¢s and says: That the inrmation contained in tl1is n�port is e result qf cplete an.d carelly conducted tests and is to the best ofhis knowledge true and conect ifi all respects. . !BED and sworn to me this ay , 2008 by ough1s G. Anderson proved to e on the hasis f satisfactory eVidece to be the. person who appeared bere me, CAROL A. Commission # 1791094 Not.c PybHc cantrn10 San Qeno TEST ENGINEER TEST OPERATIONS M.Bovard Copyright by Wyle Laboratories. The right to reproduce, exhibit, or otherwise utilize any ofthe maJeri1 c.ontai p ed herein without the express prior permission of Wyle Laboratories is orohibited. The acceotance of·a ourchase in connertionwilh thA mtAril rnlinArl hArAln hll hP Am rivlnt tn "'" nrinr nrmiinn

Upload: hoangtram

Post on 07-Mar-2018

216 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

W·B67A

TEST, ENGINEERING AND RESEARCH GROUP, SAN BERNARDINO

Our :Job No. T56261 Contract

Your P.O. No. 4500001654 Date November 19, 2008

This report contains true and correct data. obtained in the perfonnance of the test progam set forth in yourpurchase order. Test methods, results, a1d equipmet1t used are recorded on these data sheets.

Where applicable, instru11entatio11 nsed in obtail1ing this data has been calibrated using standards which aretraceable to the National Institute of Standards and Technology.

SUMMARY:

One (1) Toolbox, Part No. 0450 and identified .as Wl, was subjected to Immersion Testing in accordance withMIL-STD-810F, Paragraph 51204.

One {1) Toolbox, Part No. 0450 and identified as W2, was subjected to Blowing Dust Testing n accordance withMIL-STD-Kl OF, Paragraph 510.4.

Complete test details, including photos and equipment list, an,d test results are contained in this report.

Test Dates: 11/17/08-11/18/08

STATEOFCALIFORNIA COUNTY OF SAN BERNARDINO }ss;

Douglas G. Anderson bei11g . . duly swom, depos¢s and

says: That the information contained in tl1is n�port is the result qf complete an.d carefully

conducted tests and is to the best ofhis knowledge true and conect ifi

all respects.

. !BED and sworn to me this tjay , 2008 by ough1s G. Anderson proved to .me on the hasis o,f satisfactory eVidertce to be the. person who appeared before me,

CAROL A. Commission # 1791094

Not.cry PybHc .. cant<)rn10 San Qerncm:.tno

TEST ENGINEER

TEST OPERATIONS

M.Bovard

Copyright by Wyle Laboratories. The right to reproduce, exhibit, or otherwise utilize any ofthe maJeri;31 c.ontaiped herein without the express prior permission of Wyle Laboratories is orohibited. The acceotance of·a ourchase in conner.tionwilh thA m;:itAri::il r.:nril::iinArl hArAln i:h::ill hP. Am riv::ili:>nt tn "'"'"'""'"' nrinr n<>rmi<><>inn

Page 2: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 2 of 20

Page 3: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 3 of 20

Page 4: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 4 of 20

Page 5: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 5 of 20

Page 6: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 6 of 20

Page 7: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 7 of 20

Page 8: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 8 of 20

Page 9: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 9 of 20

Page 10: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 10 of 20

Page 11: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 11 of 20

Page 12: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 12 of 20

Page 13: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 13 of 20

Page 14: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 14 of 20

Page 15: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 15 of 20

Page 16: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 16 of 20

Page 17: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 17 of 20

Page 18: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 18 of 20

Page 19: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 19 of 20

Page 20: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Report No. 56261Page 20 of 20

Page 21: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Engineering Report 52570-1

Fungus Test

for

Pelican Products, Inc.

Prepared by

Nicole T. Duff, Technical Writer

Donald M. Knutson, Ph.D., Biologist

Approved by

David M. Gillen, Vice President

This document shall not be reproduced, except in full, without express written authorization of Environ Laboratories LLC.

In the event this document is provided to the customer in any format that may be modified or copied in any part, no

modifications, changes, or additions to this report, nor any summary hereof, shall be permitted in any manner. All original

content of this document shall be considered one entire report. Environ Laboratories LLC shall not be liable to the customer or

to any third party for unauthorized modification or misuse of this document.

Transmittal of technical data (as applicable):

ITAR/EAR related content; this document may contain technical data within the definition of the International Traffic in Arms

Regulations (ITAR) or Export Administration Regulations (EAR) and is subject to the export controls law of the

U.S. Government. Transfer of this data by any means to a foreign person or foreign entity, whether in the United States or

abroad, without an export license, ITAR exemption, or other approval from the U.S. Department of State or Bureau of Industry

and Security is prohibited.

Testing Cert 1719.01

Page 22: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Revision history

Revision Total number of pages Date Description

-- 10 July 13, 2015 Original

Page 23: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Prepared for:

Pelican Products, Inc.

Attention: Mohammad Hakami

Test dates

Start:

Completion:

6/11/2015

7/9/2015

Environ test number: 52570-1

Purchase order number:

Purchase date:

MH060915

6/8/2015

Fungus Test

1.0 Abstract

1.1 Object

Subject one Case and seven Material Samples to a Fungus Test as specified in MIL-STD-810G, with Change 1, dated April 15, 2014, Method 508.7, as requested in Pelican Products, Inc. purchase order MH060915, dated June 8, 2015.

1.2 Conclusions

Examination of the samples upon completion of the incubation period found no evidence of fungal growth. The samples were assigned a MIL-STD-810 rating of 0.

2.0 Unit(s) tested

Table 2-1: Units tested

Manufacturer Pelican Products, Inc.

Device One (1) Case Seven (7) Material Samples

One (1) Gasket

One (1) Vent

One (1) Red Label

Four (4) Plastic Samples

Model/part number 1500 N/A N/A N/A Yellow, Orange, Green, Tan

Assigned number 1 6 7 8 2, 3, 4, 5

The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number.

Page 24: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

3.0 Test requested

Subject one Case and seven Material Samples to a Fungus Test as specified in MIL-STD-810G, with Change 1, dated April 15, 2014, Method 508.7.

A mixed-spore suspension containing Aspergillus niger, Aspergillus flavus, Aspergillus versicolor, Penicillium funiculosum, and Chaetomium globosum, shall be prepared. The test samples shall be conditioned for at least 4 hours at 30°C ±1°C (86°F ±2°F) and 95% ±5% relative humidity prior to inoculation. Place the test samples in the fungus chamber along with cotton fabric control strips. Inoculate the samples and the cotton strips with the fungal spore suspension by spraying the suspension onto the strips and sample with a fine mist from an atomizer.

Incubate the test samples 30°C ±1°C (86°F ±2°F) and 95% ±5% relative. After 7 days of incubation, inspect the cotton control strips and verify chamber conditions are right for fungal growth. At least 90% of the surface area of each control strip shall be covered by fungi. If the growth is satisfactory, the chamber shall be resealed and the incubation continued until a total of 28 days has elapsed. The samples shall then be examined for fungal growth and rated according to Table 3-1 below.

Table 3-1: Microbial test evaluation scheme (MIL-STD-810G, Method 508.7)

Amount of growth Grade Organic substrates

None 0 Substrate is devoid of microbial growth.

Trace 1 Sparse or very restricted microbial growth and reproduction. Substrate utilization minor or inhibited. Little or no chemical, physical, or structural change detectable.

Slight 2 Intermittent infestations or loosely spread microbial colonies on substrate surface and moderate reproduction.

Medium 3 Substantial amount of microbial growth and reproduction. Substrate exhibiting chemical, physical, or structural change.

Heavy 4 Massive microbial growth or reproduction. Substrate decomposed or rapidly deteriorating.

Page 25: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

4.0 Instrumentation, procedure, and results

4.1 Instrumentation

All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z540.3-2006, and ISO/IEC 17025: 2005.

Table 4-1: Instrumentation list

Eq

uip

men

t N

um

ber

Des

crip

tio

n

Man

ufa

ctu

rer

Mo

del

Nu

mb

er

Las

t C

alib

rati

on

Du

e C

alib

rati

on

Ran

ge

200-151 Temperature Controller Watlow 920 3/17/2015 3/17/2016 -328ºF to +662ºF

501-006 Fungus Chamber Environ F1 N/A N/A Ambient to +120ºF; 50% to 98% RH

810-002 Microscope Me ji EMT-2 N/A N/A 10X; 30X

950-058 Data Logging System Fluke 2686A 4/20/2015 4/20/2016 -200°C to +400°C; 0% to 100% RH; 0 to 25 psia

Page 26: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

4.2 Procedure

A mixed-spore suspension was prepared in accordance with MIL-STD-810G, with Change 1, Method 508.7, Paragraph 4.4.3.2 using the American cultures listed in Section 3.0. The test units were placed in the incubation chamber. Cotton control strips were also placed near the samples in the chamber at this time. The test units were conditioned for 4 hours at 86°F and at 97% relative humidity. The test units and the cotton control strips were then inoculated with the mixed-spore suspension. The chamber was sealed, and the controls were programmed to provide the temperature and humidity cycle described in Section 3.0 of this report.

After 7 days, the chamber was opened and the cotton control strips were examined for sufficient fungal growth. Proper fungal growth was verified, so the chamber was again sealed, and the incubation period continued. Upon completion of the 4-week exposure, the test units were removed from the chamber and immediately examined for evidence of fungal growth under the microscope.

4.3 Results

Examination of the samples upon completion of the incubation period found no evidence of fungal growth. The samples were assigned a MIL-STD-810 rating of 0.

The test units were returned to Pelican Products, Inc. upon completion of the test.

Page 27: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

200.00

0.00

171.43

142.86

114.29

85.71

57.14

28.57

200.00

0.00

166.67

133.33

100.00

66.67

33.33

Fri 7/10/2015 5:10:48 AMFri 6/12/2015 5:10:48 AM 28 Days 00:00:00

Figure 4-1: Graph showing the chamber wet bulb / dry bulb temperatures (°C) during the incubation period

Page 28: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Photograph 4-1: Test units in the chamber prior to inoculation

Photograph 4-2: Case upon completion of the incubation period

Page 29: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Photograph 4-3: Yellow Plastic Sample upon completion of the incubation period

Photograph 4-4: Orange Plastic Sample upon completion of the incubation period

Page 30: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Photograph 4-5: Green Plastic Sample upon completion of the incubation period

Photograph 4-6: Tan Plastic Sample upon completion of the incubation period

Page 31: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Photograph 4-7: Gasket upon completion of the incubation period

Photograph 4-8: Vent upon completion of the incubation period

Page 32: Pelican Travel Gear & Accessories Test Report - CARiD instrumentation is calibrated regularly by instruments directly ... The test units were returned to Pelican Products, Inc. upon

Photograph 4-9: Red Label upon completion of the incubation period

Looking for dependable travel gear & accessories? Rely on Pelican for quality and long-lasting products.