pdr series
TRANSCRIPT
-
7/30/2019 Pdr Series
1/9
Datasheet
The PDR is an equipment ground faultprotection device that combineshydraulic/magnetic circuit breaker andoverload and short circuit protection andground fault protection. This breakersenses and guards against faults toground using a state of the art integrat-ed circuit. This technology detects faultsand when a fault occurs, the breakertrips and an LED illuminates. The LEDgives a clear indication that the trip
occurred as a result of leakage. This pro-tection helps prevent serious equipmentdamage and fire.
Our Circuit Breakers are designed accordingto railway regulations:
- IEC 60077 - 1/2/3
- NF F62-001 - 1/2/3
- EN 45545-2 & NF F16-101/102(fire and toxic regulations)
Proven Reliability
-
7/30/2019 Pdr Series
2/9
Genaral tecnical dats
ElectricalMaximum Voltage AC, 480 WYE/277 VAC, 50/60 HzCurrent Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 amps.
For other ratings, consult factory.Insulation Resistance Minimum: 100 Megohms at 500 VDCDielectric Strength 1960 VAC, 60 Hz for one minute between all electrically isolated terminals.Resistance, Impedance from Line to Load Terminal (Values Based on Series Trip Circuit Breaker)
Leakage to groundStandard Must Trip Leakage Current Ratings 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory.Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current.Test Button On breaker face above actuator.Leakage Trip Indicator Red LED on breaker face above actuator.
MechanicalEndurance 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.Trip Free All PDR equipment leakeage circuit breakers will trip on overload or leakage to
ground, even when actuator is forcibly held in the ON position.
PhysicalNumber of Poles 2, 3 & 4 PolesLength 106.7 mm (4.2 inches) (included switched or unswitched neutral)Width 2-pole: 76.2 mm (3.0 inches)
3-pole: 95.3 mm (3.75 inches)4-pole: 114.3 mm (4.5 inches)
Depth 63.5mm (2.5 inches)Weight 2-pole: 453.6 g (16.0 oz.)
3-pole: 606.7 g (21.4 oz.) 4-pole: 762.6 g (26.9 oz.)Standard Colors Housing - gray; Actuator - black, red, or whiteMounting Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or 35 x 15mm
per DIN EN5002).Termination Box Lug
EnvironmentalOperating Temperature -10 C to +50 C
2 http://www.morssmittrelais.com
General technical specifications - PDR-Series
1000
1
10
100
1001010.10.010.001
0.01
0.1
O
H
M
S
AMPERE RATING
CURRENT(AMPS)
0.10 - 5.0
5.1 - 20.0
15%
25%
TOLERANCE(%)
20.1 - 50.0 35%
-
7/30/2019 Pdr Series
3/9
11 AGENCY APPROVALS 5
1 UL-Recognized, CSA, TUV to EN60077 and NF F62-001
3http://www.morssmittrelais.com
3Current Rating
6Circuit
2Voltage/
Poles
PDR 244
Frequency
& Delay
1Series
B 6108
Actuator
Color
5Equipment
leakagetrip current
7Actuator
10Mounting
9Terminal
B 1 1B 1B
2 SYSTEM VOLTAGE/POLES 1
System Voltage PolesA 120VAC 1 One plus unswitched neutralB 120/240 VAC 1 TwoC 120/208 VAC 1, Two plus unswitched neutral
120/240 VAC 1D 120/208 VAC 1, Two plus switched neutral
120/240 VAC 1
E 208/240 VAC 3 ThreeF 208/240 VAC 3 Three plus unswitched neutralG 208/240 VAC 3 Three plus switched neutralP 480Y VAC 3 ThreeQ 480Y VAC 3 Three plus unswitched neutralR 480Y VAC 3 Three plus switched neutral
4 FREQUENCY & DELAY
20 50/60Hz Instantaneous22 50/60Hz Short
24 50/60Hz Medium26 50/60Hz Long
6 CIRCUIT
B Series Trip (Current)
7 ACTUATOR
A HandleB Handle with handleguard
1 SERIES
PDR
5 EQUIPMENT LEAKAGE - TRIP CURRENT (milliamps) 2
B 7C 10
D 15E 30
F 50G 100
8 ACTUATOR COLOR & LEGEND
Actuator Color Marking Marking Color Color: I-O ON-OFF DualWhite A B 1 BlackBlack C D 2 WhiteRed E F 3 White
Ordering Scheme - PDR-Series
3 CURRENT RATING (AMPERES)
410 1.000512 1.250415 1.500517 1.750420 2.000522 2.250425 2.500527 2.750430 3.000
435 3.500440 4.000
445 4.500450 5.000455 5.500460 6.000465 6.500470 7.000475 7.500480 8.000485 8.500
490 9.000495 9.500
610 10.000710 10.500611 11.000711 11.500612 12.000712 12.500613 13.000614 14.000615 15.000
616 16.000617 17.000
717 17.500618 18.000619 19.000620 20.000622 22.000624 24.000625 25.000630 30.000635 35.000
640 40.000650 50.000
10 MOUNTING 3
1 Threaded Insert 6-32 x 0.195 inches2 Threaded Insert ISO M3 x 6.5 mm
9 TERMINAL
1 Front Connected Box Lug with Pressure Plate
Notes:1 Units with a switched or unswitched neutral connection are the same size as a unit with an
additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the samephysical size as a 3-pole unit.)Switched neutral poles contain the same overcurrent protection as the other poles.
2 The leakage currents shown will cause the breaker to trip (must-trip current). The must-holdcurrent is 67% of the must-trip current.
3 All breakers are front panel mountable using screw size shown. Breakers may also bemounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail.
5 Preliminary test results showed that the breakers comply to the EN60077 and NF F62-001. Certificates for UL-Recognized and CSA are available on request. For the EN60077and NF F62-001 the certificates will be available in short notice
11Agency
approval
1
* Other values on request
-
7/30/2019 Pdr Series
4/9
4 http://www.morssmittrelais.com
Time Delay Values - PDR-Series
NOTES:Delay Curves 22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve.Delay Curves 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temperature of 25C (77F) with no preloading. Breakers are mounted in standard wall-mount position.On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These val-ues are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitiveloads and transformer loads.
AC
1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzINSTANTANEOUS
CURVE NO. 20
150
125
100 200 300 400 500 600 700 800 900
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
Instantaneous Short
Medium Long
800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzSHORT DELAYCURVE NO. 22
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT150125
100 200 300 400 500 600 700
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzMEDIUM DELAYCURVE NO. 24
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzLONG DELAYCURVE NO. 26
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
DELAY 100% 125% 135% 150% 200% 400% 600% 800% 1000% 1200%
20 No Trip May Trip --- .040 MAX .035 MAX .030 MAX .025 MAX .020 MAX .017 MAX .015 MAXTRIP
22 No Trip .700 - 12.0 --- .350 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .045 .004 - .040TIME
24 No Trip 10.0 - 160 --- 6.00 - 60.0 2.20 - 20.0 .300 - 3.00 .050 - 1.30 .007 - .500 .005 - .060 .005 - .040(SECONDS)
26 No Trip 50.0 - 700 --- 32.0 - 350 10.0 - 90.0 1.50 - 15.0 .500 - 7.00 .020 - 3.00 .006 - 2.00 .005 - 1.00
PERCENT OF RATED CURRENT
-
7/30/2019 Pdr Series
5/9
All dimensions in inches and [mm]
5http://www.morssmittrelais.com
Circuit & Terminal Diagrams - PDR-Series
TEST
P1(L1) LINE
LINEP1(L1)
TEST
(N)
LINEP1(L1) (N)
LOAD
LOAD
TEST
LOAD
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
P3(L3)
SENSOR
CIRCUIT SCHEMATICS
SOLID STATECIRCUITRY
TRIPMECHANISM
TRIPMECHANISM
1-POLE CIRCUIT
(N)
SOLID STATECIRCUITRY
P1(L)
SENSOR
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
SOLID STATE
CIRCUITRY
SOLID STATECIRCUITRY
P3(L3)
SENSOR
P3(L3)
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
LINE
TRIPMECHANISM
P2(L2)
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
P1(N)
P1(L1)P2(L2)
P2(L)
SOLID STATECIRCUITRY
P1(L1)
SENSOR
SOLID STATE
CIRCUITRY
TRIPMECHANISM
TRIPMECHANISM
LOAD
TEST
LINE
SENSOR
TEST
LOAD
P2(L2)
SOLID STATECIRCUITRY
P1(L1)
SENSOR
TRIPMECHANISM
TRIPMECHANISM
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR SENSOR
PDR D (WITH SWITCHED NEUTRAL)
LINE
(N)
2-POLE CIRCUITSPDR B
TEST
LOAD
PDR C (WITH UNSWITCHED NEUTRAL)
LINE
PDR A
TEST
(N)
LOAD
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
TRIPPED DUE TOEARTH LEAKAGE
INDICATOR
P2(L2)
P2(L2)
P2(L2)
3-POLE CIRCUITS
PDR G & PDR R (WITH SWITCHED NEUTRAL)
PDR F & PDR Q (WITH UNSWITCHED NEUTRAL)
PDR E & PDR P
POLE2(L2)
POLE3(L3)
LINE
(N)POLE1(L1)
ONI
LOAD
OFF
O
POLE IDENTIFICATION SCHEME .920 [23.37]
BOX TYPE WIRE CONNECTORSWITH PRESSURE PLATE
1.500 [38.10] 4.500 [114.30]
-
7/30/2019 Pdr Series
6/9
30
60
LINE
(2 PLACES PER POLE)
ONI
2.250 [57.15]
ONI
LEAKAGE INDICATOR
.375 [9.53]
3.000 [76.20]
ONI
.550 [13.96]
ONI
4.500 [114.30]
2.500 [63.50]
PANEL CUT-OUT DETAIL
2.260 [57.40]
.650 [16.51]
2.260 [57.40]
.265 [6.73]
TRIPPED DUE TO EARTH
1.215 [30.86]
PDR C & PDR D
PDR A & PDR B
PDR E &PDR P
2.250 [57.15]
1.125 [28.58]
2.250 [57.15]
.790 [20.10]
LOAD
PDR F, PDR G
PDR Q & PDR R
ASSEMBLY
4.200 [106.68]
TEST BUTTON
6-32 [M3] THREAD x .195 [4.95] DEEP
2.062 [52.37]
.750 [19.05]
.649 [16.48]
SCREW DRIVER
STANDARD 35mm SYMMETRICAL DIN RAIL
1.405 [35.69]
4.200 [106.68]
OPTIONAL HANDLE GUARD
REMOVAL
(35 x 7.5 OR 35 x 15mm PER DIN EN50022).
.150 [3.81]3.750 [95.25]
2.062 [52.37]
.156 DIA [3.96]
1.510 [38.35]
4 PLCS.
3.500 [88.90]
.644 [16.36]
6 http://www.morssmittrelais.com
Form & Fit Drawings - PDR-Series
All dimensions in inches and [mm]
-
7/30/2019 Pdr Series
7/9
7http://www.morssmittrelais.com
Response Fax
Please send more information for:
Call for an appointment
Please add me to the mailing list
Please remove me from the mailing list
Company: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact person: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Function: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZIP-code: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Place: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telephone number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fax number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Email: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relays (instantaneous relays, measuring and monitoring relays and electronic time delay relays)
Circuit protection (hydraulic/magnetic circuit breakers, hydraulic/magnetic ground faultbreakers and hydraulic/magnetic remote operated breakers)
High voltage and current protection relays (overcurrent, undercurrent, differential current,
overvoltage, undervoltage, differential voltage and frequency measuring & monitoring relays)
Electrical control solutions (Form, fit and function electrical control units for retrofit/refurbishmentapplications and new built applications)
Panel indicators (analogue indicators for speed, voltage, current, power etc.)
MORE INFORMATION?
Fill in the details below and return this fax to:
The Netherlands: +31 (0)30 289 88 16
France: +31 (0)1 48 55 90 01
USA: +1 (0)631 271 8898
-
7/30/2019 Pdr Series
8/9
8
France USA
Your local distributor:
For further information please contact:
Proven Reliability
The Netherlands
ComDocSolutions-2004
DS/GB PDR-Series 1.50 / 04-04
MORS SMITT TECHNOLOGIES INC.
50 North New York AvenueHuntington, NY, 11743USATel. +1 (631) 271-8858Fax +1 (631) [email protected]
http://www.morssmittrelais.com
MS RELAIS SAS
Tour Rosny 2Avenue du Gnral de GaulleF - 93118 Rosny-sous-Bois CedexFranceTel. +33 (0)1 48 12 14 40Fax +33 (0)1 48 55 90 [email protected]
http://www.morssmittrelais.com
NIEAF-SMITT BV
Vrieslantlaan 6NL - 3526 AA, UtrechtThe NetherlandsTel. +31 (0)30 288 13 11Fax +31 (0)30 289 88 [email protected]
http://www.nieaf-smitt.nl/railway
-
7/30/2019 Pdr Series
9/9
Aust ral ian Dist ri bu to r
Relay Monitoring Systems Pty Ltd6 Anzed CourtMulgrave, Victoria, 3170, Australia
Phone: +61 3 8544 1200Fax: +61 3 8544 1201Email: [email protected]: www.rmspl.com.au
mailto:[email protected]://www.rmspl.com.au/http://www.rmspl.com.au/mailto:[email protected]