Standards
Atomic Absorption
THGA Graphite Tubes and Supplies
Lumina Hollow Cathode Lamps
QUICK-FIND INDEX Page #
Autosampler Sample Cups 11
Autosampler Sample Probes 9
Burner Heads and Components 13
Electrodeless Discharge Lamps 46
Filters, Regulators, andSupplies 36
Flow Injection SamplingSupplies 21
HGA Graphite Tubes andContact Cylinders 31
Lumina Hollow Cathode Lamps 39
Matrix Modifiers 67
MHS System and Supplies 49
Sample Preparation Supplies 50
Nebulizers 16
Standards 65
THGA Graphite Tubes andContact Cylinders 34
WinLab32 Software for AA 70
HGA Graphite Tubes and Supplies
PerkinElmer offers a wide selection of superior quality products designed to work withyour PerkinElmer instruments. Our precision-designed products deliver the peace ofmind that comes from knowing that youll get the results you need.
The Quick Find Index to the left will help you find products fast. For your convenience,products are alphabetized by category, sub-category, and family. There is also a morecomplete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.
PerkinElmer tubes are manufactured to the highest qualityspecifications. To ensure high quality and consistency, aspecific grade of high-density base graphite material hasbeen developed for PerkinElmers exclusive use. This basegraphite material is used for the manufacturing of allPerkinElmer graphite tubes.Page 31
Every genuine PerkinElmer Lumina lamp is designedfor use with, and tested on, our spectrometers toassure compatibility and the highest performance.PerkinElmer offers a wide range of single-element andmulti-element HCLs, which are ideal for determining mostelements by atomic absorption spectroscopy.Page 39
PerkinElmer offers a wide selection of atomic absorptioncalibration standards. Each solution is supplied with acomprehensive Certificate of Analysis that documentsthe quality. To ensure that your measurements areaccurate, you can rely on our certificates to providecomplete information.Page 65
Our exclusive design ensures even heating over the entirelength of the tube. PerkinElmers unique, transverselyheated graphite tube includes an integrated platform. Theexceptionally uniform temperature distribution obtainedwith transverse heating significantly reduces or eliminatescondensation of the sample matrix components andmemory effects, and improves the atomizationefficiency for refractory elements.Page 34
-
AAnalyst 200The AAnalyst 200 dramatically changesthe way instruments are used and serviced,while maintaining all of the performanceusers have come to expect from PerkinElmer.The system incorporates innovationstypically only offered on expensive research-grade instrumentation. True double-beamEchelle optics combined with the power ofa solid state detector delivers performancelevels not typically available with flameAA. Plus, fully automated gas controlsand integrated safety checks yield thesafest flame AA system available today.
Features: Intuitive touch screen is easy-to-use
no training required Snap-in, snap-out parts are easily
replaced, so there is no downtime Rugged design can handle the toughest matrices PerkinElmer reliability and performance
at an affordable price Features the first true double-beam
Echelle optical system
AAnalyst 400The AAnalyst 400 system is designed forthe rigorous needs of todays analyticallaboratory, with proven WinLab32software providing all the flexibilityand power you need in an easy-to-use,easy-to-learn package.
AAnalyst 600The AAnalyst 600, a dedicatedtransversely heated graphite atomizer(THGA) system, offers the best ingraphite furnace. With Zeemanbackground correction, the AAnalyst600 exceeds the requirements of todayslaboratories, whether analyzing difficultsamples or for achieving the lowestdetection levels. The high-light-throughput optical system combinedwith a solid-state detector, providesthe highest quality efficiency andsignal-to-noise performance of anyAA system on the market.
AAnalyst 700The AAnalyst 700 Atomic AbsorptionSpectrometer offers productivityenhancing features for flame and furnaceatomic absorption in a proven cost-effective design. The fully integratedbenchtop system includes flame andheated graphite furnace atomizers(HGA) with continuum sourcebackground correction.
AAnalyst 800For laboratories that need the best in bothflame and THGA furnace, the AAnalyst800 provides a fully integrated benchtopsystem with superior performance. Withthe AAnalyst 800, switching betweenflame and furnace is as simple as a clickof the mouse and includes automaticalignment for optimum performance.The high-light-throughput optical systemcombined with a solid-state detector,provides the highest quality efficiencyand signal-to-noise performance of anyAA system on the market.
OVER 40 YEARS OF EXPERTISEWith over 40 years experience and a product line thatincludes flame AA systems, high-performance graphitefurnace AA systems, flexible ICP-OES systems, and themost powerful ICP-MS systems, PerkinElmer is theundisputed leader in inorganic analysis. We haveplaced over 40,000 systems throughout the world,performing inorganic analyses every hour of every day.
PerkinElmer is a world leader in chemical analysis. Ouranalytical instrument technologies serve the rapidlyevolving pharmaceutical, chemical, environmental,forensics, and semiconductor industries, providingintegrated solutions from sample handling andanalysis to communication of test results.
The World Leader inAtomic Absorption
7
AAnalyst 200
-
Ato
mic
Ab
sorp
tio
nA
uto
sam
ple
r S
up
plie
s an
d A
cces
sori
esAutosampler Supplies and AccessoriesAutosampler Flame/FIAS Trays and Vessels
8
Description Part No. Each
AS-91 Plexiglass Cover B3000111 1103AS-93plus Dust Cover B3140770 1001
Plexiglass cover for reduced contaminationof samples from ambient particulates
Adapter Plate for Gilson Racks for AS-93plus B3140647 48Required in order to use Gilson racks on an AS-93
AS-93plus Rinsing Kit
Includes: Part No. Each
Adapter M B0507919 15Connector B3140715 2Pump Tube - 1.14 mm i.d., (pkg. 6) B3140730 57Pump Tube - 2.79 mm i.d., (pkg. 6) B3140721 60PVC Rinse Liquid Feed Tube - 2 m B0048139 1Tygon Drain Tube - 2 m B0509650 16Rinsing Port B3140622 36
AS-90plus Rinsing KitIncludes the rinse vessel (B300-0156) and the appropriateadapter and tubing. The vessel may notfit trays manufactured prior to 1996.
AS-90/90A/90plusCapacity Sample Vessel Size Part No. Each
Tray A-144 4.5 mL, 6 mL, 8 mL B3000133 338Tray B-98* 15 mL, 16 mL B3000132 113Tray C-36 50 mL B3000135 338Blank Tray B0501056 421
AS-91Capacity Sample Vessel Size Part No. Each
Tray E-218 4.5 mL, 6 mL, 8 mL B0509554 440Tray F-152 15 mL, 16 mL B0509555 440Tray G-55 50 mL B0508520 440
AS-93plusCapacity Sample Vessel Size Part No. Each
9/29 50 mL/15 mL B3001647 2630 50 mL B3140621 2660 15 mL, 16 mL B3140618 2690 4.5 mL, 6 mL, 8 mL B3140617 26
AS-90/90A/90plus/91/93plus
Translucent polypropylenevessels with excellentchemical resistance.
Sample Vessel Volume Quantity Part No. Each
4.5 mL 1000 N9301204 756 mL** 500 B0193235 3258 mL 1000 B0508901 45315 mL** 500 B0193233 32516 mL 1000 N9301205 9350 mL** 500 B0193234 257
Caps, for 8 mL VesselsPackage of 1000.
AS-90/91 Wash Vessel, PolypropyleneIncludes cover (250 mL).
AS-50/51
Description Part No. Each
Polystyrene Test Tubes 00471441 32Cone-shaped bottoms permit use of smallsamples. Clear, affordable polystyrene isrecommended for use with most aqueoussolutions (125 test tubes)
Berzelius Tall-form Beaker 00471440 6Pyrex beaker (400 mL) used as a washvessel for the autosampler
Sample Trays
Sample Vessels
Rinsing Kits
Tubes and Beakers
*Polypropylene sample tray.
** Includes screw caps.
Trays A, C, E, F, and G are powder-coated, corrosion-resistant aluminum.
AS-93plus sample trays are polypropylene.
Part No. Each
B0508902 153
Part No. Each
B0501258 36
Accessories
AS-93plusPart No. Each
B3140236 292
Part No. Each
B3000166 185
()
()
()
()
()
()
()
()
()
()
()
-
Au
tosam
pler S
up
plies an
d A
ccessories
Ato
mic
Ab
sorp
tion
9
Autosamplers automate standard and sample introductionfor instrument calibration and sample analysis via softwarecommands, extending the spectrometers capabilities tothose of a fully-automated analytical workstation.
Stainless SteelDescription Part No. Each
Sampling Probe Assembly, B3000159 1980.6 mm i.d.
Stainless steel sampling probe and screw fitting, B3000152,and flame capillary tubing assembly, B3000157.
Sampling Probe Assembly, B3000160 1980.6 mm i.d.
Stainless steel sampling probe and screw fitting, B3000152and FIASTM capillary tubing assembly B3000158.
Standard Sampling Probe Assembly, B3000161 1981.0 mm i.d.
Stainless steel sampling probe and screw fitting, probe B3000152,and FIAS capillary tubing assembly B0191060.
Corrosion-ResistantDescription Part No. Each
Flame Sampling Probe Assembly, B3001770 2170.6 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organicsolvents, except NMP. Includes sampling probe with FEP tube and screwfitting (B3000055) and capillary tubing assembly (B3000157).
Sampling Probe Assembly, B3001771 1980.6 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organicsolvents, except NMP. Includes sampling probe with FEP tube and screwfitting (B3000055) and capillary tubing assembly (B3000158).
Standard Sampling Probe Assembly, B3001772 2171.0 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organicsolvents, except NMP. Includes sampling probe with FEP tube and screwfitting (B3001769), and capillary tubing assembly (B0191060).
Corrosion-Resistant Sampling Probeswith Screw FittingSuitable for inorganic acids and most organic solvents,except NMP. Requires, but does not include, one of thecapillary tubing assemblies described below.
Description ID Part No. Each
Corrosion-Resistant Sampling Probe 0.6 mm B3000055 134Corrosion-Resistant Sampling Probe 1.0 mm B3001769 97
Stainless Steel Sampling Probe w/Screw FittingRequires, but does not include,one of the capillary tubingassemblies described below.
Capillary Tubing AssemblyDepending on the autosampler application, the samplingprobe can be equipped with any of three types of capillarytubing assembly, which have different tubing diameters andeither one or two screw fittings.
Description Part No. Each
1 m length, 0.6 mm i.d., one fitting B3000157 401 m length, 0.6 mm i.d., two fittings B3000158 181 m length, 1.0 mm i.d., two fittings B0191060 19
Used Oil Autosampler ProbeAutosampler probe for the AS-90plus and the AS-93plusAutosamplers. The probe includes aparticulate filter on the tip to removefibers. For use in used oil analysis.
Stainless Steel Sampling ProbeFor use with both aqueousand organic samples. (pkg. 5)
Platinum/Rhodium Sampling Probe**Accessory probe recommended for usewhen samples corrosive to stainlesssteel are being analyzed. (pkg. 1)
Quartz Sampling Probes***Probe recommended for use whensamples corrosive to stainless steelare being analyzed. (pkg. 5)
Sampling Probe Cleaning Wire (1 M)For AS-90/91/90plus/93plus probe.
Sampling Probe Assemblies,AS-90/90A/90plus/91/93plus
Sampling Probes, AS-50/51
Part No. Each
B0505962 42
Part No. Each
B3000152 143
** Not recommended for use with samples containing aqua regia.*** Cannot be used with samples containing hydrofluoric acid or other
reagents corrosive to quartz.
* Probe cannot be used with AS-90s, which have the older sampling probe holder.
Sampling Probe Assembly Components,AS-90/90A/90plus/91/93plus
Part No. Each
N0771529 249
Part No. Each
00471422 18
Part No. Each
00471420 363
Part No. Each
N0580540 112
Autosampler Supplies and AccessoriesAutosampler Flame/FIAS Probes
Stainless Steel ProbePart No. B3000152
Sampling Probe Supplies
()
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nA
uto
sam
ple
r S
up
plie
s an
d A
cces
sori
esAutosampler Supplies and AccessoriesDilution System Supplies
10
4 4
5
3
2
1
1
AutoPrep 50 Tubing
The AutoPrepTM 50 provides automatic, intelligent on-linedilution capabilities for flame Atomic Absorption.
Key features of the AutoPrep 50 include:
Fully automatic sample introduction Automatic intelligent selection of dilution range Automatic preparation of multiple standards from
a single stock solution
Integrated software control
Diluter Parts
Description Part No. Each
Pump Assembly, 5 mL B3141052 103(includes pump head and piston assembly)
Sample Holding Coil, 5 mL B3140123 117Valve 1 (V1, 3-port with red mark) B3002072 40Valve 2 (V2, 3-port with yellow mark) B3002094 40Valve 3 (V3, 3-port with black mark) B3002076 41Valve 4 (V4, 3-port with black mark) B3002091 40T-union (T1, black mark) B3002097 45Thumbscrew for Valves and T-union B3140211 26Thumbscrew for Sample Holding Coil B3140210 26Sampling Probe for AS 90/91, complete, B3140244 124
connects AS 90/91 to AutoPrep 50 Valve 3
Nuts and Ferrules
Description Part No. Each
Front Ferrule for 2.4 mm o.d. tubing (B0017998) B3001333 11Back Ferrule for 2.4 mm o.d. tubing (B0017998) B3001334 10Nut for 2.4 mm o.d. tubing (B0017998) B3001335 7Front Ferrule for 1.6 mm o.d. tubing (B0029792) 09920123 19Back Ferrule for 1.6 mm o.d. tubing (B0029792) 09920124 16Nut for 1.6 mm o.d. tubing (B0029792) B0080333 7
Tubing
Description Part No. Each
Diluent and Waste Tube B3140226 40(connects to V1 or V4), complete,1.7 mm i.d., 2.4 mm o.d., 1.2 m long
Diluent Feed Tube (connects to V2), B3140227 34complete 1.0 mm i.d.,1.6 mm o.d., 0.7 m long
PTFE Tubing B0509652 3(connects the T-union with thenebulizer) 0.56 mm i.d., 1.67 mm o.d.
PTFE Tubing, used to interconnect B0029792 2valves, 1.0 mm i.d., 1.6 mm o.d.
PTFE Tubing, used to connect thesample pump to the valve (V1), B0017998 31.7 mm i.d., 2.4 mm o.d.
Tubing Cutter B3000019 43
5
4
3
2
1
AutoPrep 50
AutoPrep 50
()
()
()
-
Au
tosam
pler S
up
plies an
d A
ccessories
Ato
mic
Ab
sorp
tion
Autosampler Supplies and AccessoriesGraphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800
11
Heavy-duty construction prevents cracking or tipping Conical design allows for use of entire sample
Your choice of materials:
Polystyrene Clear, recommended for use with mostaqueous solutions.
Polyethylene Translucent, low density, recommendedfor use with most aqueous and organic solutions.
Teflon Recommended for use with most concentratedacids including HF and for analyses where the lowestdetection levels are required.
Polypropylene Translucent. No known solvent atroom temperature.
Graphite Furnace Autosampler Cups
Volume Composition Qty. Part No. Each
7 mL**** Polypropylene 100 B3001567 333.5 mL** Polystyrene 100 B0129303 342.5 mL** Polypropylene 1000 B3001566 472 mL* Polyethylene 1000 B0087056 532 mL* Polystyrene 1000 B0119079 822 mL* Teflon 30 B0087600 2421.2 mL*** Polypropylene 2000 B0510397 61
PliersFor 1.2 mL sample cups.
Description Part No. Each
For Model AS-40Sample Tray B0101045 459
For Models AS-60/70Sample Tray* B0510417 66
For Models AS-71/7240-Position Tray, Plastic B0510417 66
35 sample locations for 2 or 3.5 mL sample cups*
80-Position Tray, Plastic B0510404 4175 sample locations for 1.1 mL sample cups*
Sample Tray Cover B3001330 23
For Model AS-80088-Position Tray, Polypropylene B3001507 21
80 sample locations for 2, 2.5, or 3.5 mL samplecups. Each sample tray also has eight positionsfor 7 mL reagent containers.
148-Position Tray, Polypropylene B3001506 21132 sample locations for 1.1 mL sample cupsand eight locations for 2.5 or 3.5 mL samplecups. Each sample tray also has eight positionsfor 7 mL reagent containers.
AS-800 Supplies
Arm B3002046 8
Sampling Arm Collar B3001465 14
Set Screw for Collar B0055900 1
Sample Tray Cover B3001505 17
* Each sample tray has five positions for 30 mLcloverleaf-shaped reagent containers
Description Part No. Each
Inlet (complete) B3002007 267Includes ferrules and connector
Outlet (complete) B3002006 267Includes ferrules and connector
Solvent-Resistant Check Valves
Description Part No. Each
Inlet B0105973 437Outlet B0105974 359
Autosampler Sample Cups
Part No. Each
B0510398 11
* For use with AS-40/60/70/71/72/800 *** For use with AS-71/72/800** For use with AS-60/70/71/72/800 **** For use with AS-800
Autosampler Trays
Check Valves
148-Position Tray, Polypropylene(For Model AS-800)Part No. B3001506
88-Position Tray, Polypropylene(For Model AS-800)Part No. B3001507
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nA
uto
sam
ple
r S
up
plie
s an
d A
cces
sori
esAutosampler Supplies and AccessoriesGraphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800
12
Rinse Tubing FerrulesDescription Size Part No. Each
Front Ferrule 2.45 mm i.d. B3001333 11Rear Ferrule 2.45 mm i.d. B3001334 10
Sample Tubing Ferrule Kit (1.6 mm i.d.)Used with B0129258 andB0101161 sampling capillaries.Contains 5 front and 5 rear ferrules.
Tubing Only (PTFE)*Description Size Part No. Each
Rinse Tubing 1.6 mm o.d. B0029792 2Sample Tubing 2.45 mm o.d. B0017998 3
For Models AS-40/60/70/71/72
Round Reagent ContainersFor blank solutions, reagent solutions, or matrix modifiers.
Volume Composition Part No. Each
20 mL PTFE* B0103037 4020 mL Polypropylene** B0101164 1025 mL Polystyrene*** B0102332 5
For Models AS-60/70/71/72
Cloverleaf-ShapedReagent Containers30 mL polypropylene.
Resists most acid solutions Provides more reagent volume, yet
occupies only one sample space
Allows you to insert up to fivedifferent reagent solutionsor matrix modifiers for one run
Rinse Solution Bottle (2 L)
Waste Solution Bottle (2 L)
Solvent- and acid-resistant sampling components PTFE pipette tips and capillaries for reduced contamination Easy replacement
Description Part No. Each
For Model AS-40Sampling Capillary B0101161 242
For Models AS-60/70/71/72/800Sampling Capillary B0129258 242
Ferrule Kits
Part No. Each
B0132799 34
Part No. Each
B0104281 110
Part No. Each
B0104987 41
* Solvent-resistant (AS-40 only)** Suitable for organic solutions*** Not suitable for organic solutions
Sampling Capillaries
AS-800 Autosampler
Reagent Containers
Part No. Each
B0086142 68
* Order per meter.
Sampling Capillary(For Models AS-60/70/71/72/800)Part No. B0129258
()
()
()
()
()
()
()
()
-
Bu
rne
r Syste
m C
om
po
ne
nts
Ato
mic
Ab
sorp
tion
Burner System ComponentsAAnalyst 100/200/300/400/700/800
13
AAnalyst Burner Heads cannot be used with other PerkinElmerAA Spectrometers.
Single-Slot Nitrous Oxide-AcetyleneThe 5 cm nitrous oxide burner head is requiredfor nitrous oxide-acetylene operation. Thisburner head can also beused with air-acetyleneor rotated to providereduced sensitivity.
Single-Slot Air-AcetyleneThe 10 cm burner head is designed to be usedwith the air-acetylene flame. Because of itslong burner path length, it provides the bestsensitivity for air-acetylene elements.
Three-Slot Air-AcetyleneThe three-slot burner head (10 cm) is designedto be used when analyzing samples with highconcentrations of dissolved solids. The three-slot burner head is notcompatible with someolder gas control systems.
Single-Slot Air-AcetyleneA 5 cm air-acetylene burner head (5 cm) isavailable for applications in which reducedsensitivity is required. It can be rotated toprovide further sensitivityreduction, and it has a wideslot to prevent clogging.
Burner Head Cleaning Tool
Burner Heads
Components Part No. Each
Viton Burner Head O-Ring 09902219 2Burner Mixing Chamber Assembly 00570948 402Clamping Ring N0401171 26Flow Spoiler 00572561 20End Cap O-RingAqueous (Viton) 09902147 2Organics (Corkprene) 00472014 3Aqueous and Organics (KALREZ)* 09921044 266
End Cap Assembly N0370392 287Used with the following nebulizers:03030352, 03030404, 03030299.
End Cap Assembly 00570984 440Used with the following nebulizers:B0505480, B0505590, N0370394,N0370393, N3150188.
Impact Bead and Retainer AssemblyThis can only be used with the End Cap Assembly(Part No. 00570984).
Description Part No. Each
Seal Plug 00572624 38Large Impact Bead O-Ring 09902240 3O-Ring (1/8 in.) 09902236 2Impact Bead 00572615 70Impact Retainer 00572695 30Split Lockwasher 09911286 1Binding Head Screw 09910148 1
Burner Gasket Kit 00470988 71
Includes: Kit Qty. Part No. Each
Corkprene End Cap O-Ring 5 00472014 3Viton End Cap O-Ring 3 09902147 2Viton Burner Head O-Ring 1 09902219 2Small Impact Bead O-Ring 3 09902236 2Large Impact Bead O-Ring 3 09902240 3
Magnet Assembly for AAnalyst N2010381 32700/800
Magnet Assembly for AAnalyst N1010215 32100/200/300/400
Components Part No. Each
Drain Tubing, AAnalyst 100/200/300/400/700/800 02507987 22AAnalyst 700/800 Drain Assembly N2011074 1346AAnalyst 100/300 Drain Assembly N0400058 779Drain Bottle 09904991 112
Burner System Components
BCDEF
G1
G2
1234567
Part No. Each
N0400100 982
Part No. Each
N0400102 982
Part No. Each
N0400103 982
Part No. Each
N0400101 982
Part No. Each
03031573 3
* Recommended for use when determination of organic and acid basedsolutions required
1
22
3
56
7
3
4
G1 G2
F
E
D
A
B
C
Drain Components
A
A
A
A
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nB
urn
er
Sys
tem
Co
mp
on
en
ts
14
Burner System ComponentsModels 2280, 2380, 3030(B), 3100, 3110, 3300, 4000*, 5000*, and 5100 PC
Single-slot Burner Head 00400266 893
The 10 cm burner head is designed to be used with theair-acetylene flame. Because of its long burner path length,it provides the best sensitivity for air-acetylene elements.
Nitrous Oxide Burner Head 00400277 867
The 5 cm nitrous oxide burner head is required for nitrousoxide-acetylene operation. This burner head can also be usedwith air-acetylene or rotated to provide reduced sensitivity.
Three-slot Burner Head 00400289 867
The three-slot burner head is designed to be used whenanalyzing samples with high concentrations of dissolved solids.The three-slot burner head is not compatible withsome older gas control systems.
Burner Head Cleaning Tool 03031573 3
Components Part No. Each
Viton Burner Head O-Ring 09902219 2Aqueous Viton End Cap O-Ring 09902147 2Organic (Corkprene) End Cap O-Ring 00472014 3Aqueous/Organic (Kalrez) 09921044 266
End Cap O-RingClamping Ring 00572616 78Stainless Steel Locking Ring 00572737 107
Use N0371071 for Models 3300,3110, and 3100
End Cap Assembly** 00570984 440Flow Spoiler 00572561 20Burner Mixing Chamber 00570948 402
Impact Bead Assembly
Impact Bead 00572615 70Seal Plug 00572624 38O-Ring (1/4 in./6 mm i.d.) 09902240 3O-Ring (1/8 in./3 mm i.d.) 09902236 2Impact Retainer 00572695 30Split Lockwasher 09911286 1Binding Head Screw 09910148 1
Burner Gasket Kit
Includes: Kit Qty. Part No. Each
Corkprene End Cap O-Ring 5 00472014 3Viton End Cap O-Ring 3 09902147 2Viton Burner Head O-Ring 1 09902219 2Small Impact Bead O-Ring 3 09902236 2Large Impact Bead O-Ring 3 09902240 3
Burner Drain Assembly 00470391 236Includes Drain Loop and Interlock only, for Models 2280, 2380, 3030(B),4000, 5000, and 5100 PC.
Burner Drain Assembly N0370149 252Includes Drain Loop and interlock only, for Models 3100, 3110, and 3300.
Components Part No. Each
For Air-Acetylene Burner Head (short pin) 00400276 56For Nitrous Oxide Burner Head (long pin) 00400275 56Hold Down Cable 03030130 10
Burner Heads
Cable and Pin Assemblies
E3
E2
E1
Burner System Components
E1
E2
E3
123
4
A
5
BC
D67891011
* For use on models 4000 and 5000 shipped after May 1980** A different end cap assembly, N0370392, is required for use
with the high-sensitivity nebulizer
E
5
C
1
4
B2
3
A D
8
6
7
7
8
910
11
Part No. Each
00470988 71
()
()
()
()
-
Bu
rne
r Syste
m C
om
po
ne
nts
Ato
mic
Ab
sorp
tion
Burner System ComponentsModels 1100(B), 2100, and 4100
15
Single-Slot Burner Head B0162668 918
The 10 cm burner head is designed to be used withthe air-acetylene flame. Because of its long burnerpath length, it provides the best sensitivity forair-acetylene elements.
Nitrous Oxide Burner Head B0162669 1530
The 5 cm nitrous oxide burner head is required fornitrous oxide-acetylene operation. This burner headcan also be used with air-acetylene or rotated toprovide reduced sensitivity.
Burner Head Cleaning Tool 03031573 3
Components Part No. Each
1 Viton Burner Head O-Ring 09902219 22 Aqueous End Cap O-Ring B0158690 113 Organic (Corkprene) End Cap O-Ring B0158598 74 Hold Down Wire (Pkg. 1, not shown) B0160697 475 Flow Spoiler 00572561 206 Burner Mixing Chamber B0153250 5237 Impact Bead Assembly B0151579 5808 Impact Bead, Ceramic B0158616 79
A End Cap and Drain Interlock Assembly B0151573 561B Insert B0157117 38C Clamping Ring B0162671 226
Aqueous Burner Gasket Kit Assembly B0155546 210For Aqueous Solutions.
Includes: Kit Qty. Part No. Each
Viton Burner Head O-Ring 1 09902219 2Aqueous End Cap O-Ring 1 B0158690 11Corkprene End Cap O-Ring 5 B0158598 7Plug O-Ring (Aqueous) 2 B0151697 1O-Ring between End Cap and Drain Vessel 1 B0129926 1
Organic Burner Gasket Kit Assembly B0173404 848For Organic Solutions. Includes Gaskets, O-Rings, and Seals for theModels 4100, 2100, or 1100(B). Delivered in convenient storage box.
Includes: Kit Qty. Part No. Each
Plug O-Ring 3 B0174378 56O-Ring and Drain 1 B0174379 50End Cap Gasket 1 B0174380 45O-Ring and Bead Holder Assembly 1 B0181842 57O-Ring on Nebulizer Venturi 1 B0190001 45O-Ring, High-Sensitivity Nebulizer 1 B0190672 29Drain Tube (2 m) 1 B0102949 12
Burner Heads
E
E
J
E
I
9
C
B
10
11
H
FG
Burner System Components
91011
CB
FGHIJ
Burner Head Cleaning ToolPart No. 03031573
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nB
urn
er
Sys
tem
Co
mp
on
en
tsBurner System ComponentsNebulizers
16
PerkinElmer nebulizers are available in a variety ofconfigurations to meet all of your analytical needs.
The nebulizer is one of the most important components ina flame AA spectrometer. Sample solutions, with differingphysical properties, must be converted into an aerosol ofsmall, similarly sized droplets. This places great demandson the design of the nebulizer.
All PerkinElmer nebulizer assemblies are adjustable foroptimized performance and include easily interchangedcapillary assemblies for simple, reduced-cost maintenance.PerkinElmer nebulizers are manufactured to exacting tolerancesto provide maximum sensitivity. Universal, or standard,nebulizers are less expensive than the corresponding high-sensitivity nebulizers and provide a lower level of sensitivity.The universal, or standard, nebulizers typically providebetter precision and reduced carryover interference whenused with solutions that contain high dissolved solids andcontent of higher analyte concentrations.
Corrosion-Resistant NebulizerFor all solutions containing hydrofluoric acid or aqua regia
For all solutions containing high concentrations ofdissolved solids
All internal components in contact with solutions areconstructed of plastic to resist corrosion fromconcentrated acids
Reduced performance compared with stainless steel orplatinum/rhodium nebulizers
GemTip NebulizerCorrosion-resistant and can be used to aspirate almostall solutions, even those solutions containing a highpercentage of acids
Designed to obtain optimum sensitivity, detection limits,and precision with flame atomic absorption for bothair-acetylene and nitrous oxide-acetylene flames
High-Sensitivity NebulizersProvide maximum sensitivity, precision, and freedomfrom analytical interferences
The high-sensitivity nebulizer with platinum/iridiumcapillary is for most solutions, but not for precious metalsamples containing aqua regia
High-sensitivity nebulizer with tantalum capillary usedfor solutions containing aqua regia
Platinum Alloy NebulizerRecommended for most concentrated acidscontaining >5% acid
Includes a platinum alloy needle assembly and atantalum venturi
Provides maximum chemical resistance
Not suitable for use with aqua regia or hydrofluoric acid
Stainless Steel NebulizerFor most solutions containing
-
Bu
rne
r Syste
m C
om
po
ne
nts
Ato
mic
Ab
sorp
tion
Burner System ComponentsNebulizer Assemblies and Components Quick Reference
17
Plastic Body Nebulizers
For AAnalyst 100/300/700/For AAnalyst 800, Models 3100/3110/3300/200/400 5000/5100 PC and Earlier AAs 1100(B)/2100/4100
Stainless Steel Body Nebulizers
A
B
A
B
A
B
D
F
E
A
D
F
C
E
GemTip Nebulizer (see page 18) Part No. Each Part No. Each Part No. Each
GemTip Nebulizer Assembly3 N0370394 663
High-Sensitivity GemTip Nebulizer Assembly3 N0370393 1167
High-Sensitivity Nebulizer with Pt/Ir Capillary4 (see page 19) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly3 N3150188 423 B0505480 1518 B0501029 1518
Nebulizer End Cap Nut B0501026 7 B0501026 7
Nebulizer Spacer 09902015 6
Nebulizer Body B0506666 166 B0506668 166
Impact Bead B0505086 63 B0505086 63 B0505086 63
Locking Ring B0501025 7 B0501025 7
Capillary Assembly B0501022 242 B0501022 242
High-Sensitivity Nebulizer with Tantalum Capillary4 (see page 19) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly3 B0505590 1734 B0505589 1734
Nebulizer End Cap Nut B0501026 7 B0501026 7
Nebulizer Body B0506666 166 B0506668 166
Capillary Assembly B0505588 599 B0505588 599
Impact Bead B0505086 63 B0505086 63
Locking Ring B0501025 7 B0501025 7
Corrosion-Resistant Nebulizer1 Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030404 752 N3110110 1167
Capillary Assembly 03030402 242 03030402 242
Capillary Assembly for AS-51 or AS-50 00570957 236 00570957 236
O-Ring Kit N9300065 84 N9300066 84
Venturi 03031920 134 03031920 134
Platinum Alloy Nebulizer1 Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030299 1059 N3110111 1518
Capillary Assembly2 03030433 395 03030433 395
O-Ring Kit N9300065 84 N9300066 84
Venturi 03033124 536 N3111158 854
Stainless Steel Nebulizer1 (see page 20) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030352 606 N3110109 1001
Capillary Assembly 03030354 134 03030354 134
O-Ring Kit N9300065 84 N9300066 84
Venturi 03031810 134 B0166503 111
1 - Stainless steel body 2 - Etched with a P for identification 3 - Requires End Cap Assembly (N0370392) 4 - Inert plastic body with red adjusting ring
C
A
() () ()
() () ()
() () ()
() () ()
() () ()
() () ()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nB
urn
er
Sys
tem
Co
mp
on
en
ts
18
Burner System ComponentsNebulizers and Components
For AAnalystTM 100/300/700/800*
Description Part No. Each
Universal GemTip Assembly Complete** N0370394 663High-Sensitivity GemTip Assembly Complete** N0370393 1167
Component Part No. Each
Capillary Tubing 09908265 29Adjustment Nut N0371492 25Gland Nut N0371505 13Teflon Tubing 09985708 7Capillary Holding Assembly*** N0371520 223Capillary Holding Assembly**** N0371522 223O-Ring 09926083 10Impact Bead***** B0505086 63O-Ring 09902015 6O-Ring****** B0174378 56Body Assembly*** N0370398 402Body Assembly**** N0370399 427Locking Nut N0371493 12Spring 09902473 1Connector Nut N0371485 13Magnet Holder Assembly N1010215 32
12345
678
9
10111213
1
2
34
5
6
1110
9 8
7
13
12
Nebulizer Capillary Tubing10 ft. (3 m) length of 0.58 mm i.d.polyethylene tubing, for use withthe stainless steel, platinum/rhodium and GemTipTM Nebulizers.Not suitable for corrosion-resistantnebulizers where capillary tubing ispart of capillaryassembly. Not
compatible with N3150188 Nebulizer.
Nebulizer Cleaning WiresMade of soft alloy copper,these cleaning wires arespecially deburred to preventscratching of the orifices andinternal components of thenebulizers while cleaning.Use only PerkinElmercleaning wires to cleannebulizers. (pkg. 5)
Nebulizer GreaseA small quantity of Apiezon-Lgrease helps to lubricate theO-Ring seals for reassembly andensures leak-proof operation. Atube of grease is supplied witheach complete nebulizer assembly.
However, you should order the tube if you purchase separatecapillary and venturi sections.
Accessories
Part No. Each
03030135 17
Part No. Each
03030405 9
Part No. Each
09908265 29
* Shipped before Fall 1999** Requires End Cap Assembly (N0370392)*** For Universal GemTip Nebulizers**** For high-sensitivity GemTip Nebulizers***** Included with high-sensitivity GemTip Nebulizer only****** Organic Resistant
GemTip Nebulizer
GemTip Nebulizers
()
()
()
()
()
-
Bu
rne
r Syste
m C
om
po
ne
nts
Ato
mic
Ab
sorp
tion
Burner System ComponentsNebulizers and Components
19
C 21 F22
23 E DA
For Models AAnalyst 100/300/700/800/1100(B)/2100/3100/3110/4100/5100 PC
Description Part No. Each
High-Sensitivity Nebulizer Assembly withPt/Ir Capillary B0505480 1518High-Sensitivity Nebulizer Assembly withTantalum Capillary B0505590 1734
Components Part No. Each
O-Ring B0174378 56Spring B0165332 3O-Ring B0190672 29
/ / / / See chart on page 17
High-Sensitivity Nebulizers*
212223A C D E F
For Models AAnalyst 200/400/700*/800*
Description Part No. Each
High-Sensitivity Nebulizer Assembly withPt/Ir Capillary N3150188 423
Components Part No. Each
Impact Bead Structure B0505086 63Nebulizer Spacer 09902015 6
High-Sensitivity Nebulizerwith Pt/Ir Capillary
C
1
C1
High-Sensitivity Nebulizer with Pt/Ir Capillary
High-Sensitivity Nebulizer
* Requires End Cap Assembly (N0370392)
* Requires End Cap (N0370392)
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Burner System ComponentsNebulizers and Components
Ato
mic
Ab
sorp
tio
nB
urn
er
Sys
tem
Co
mp
on
en
ts
20
Stainless Steel BodyNebulizers and Parts
For Models AAnalyst 100/300/700/800,* 5100 PC,5000, 3300, 3110, 3100, and Earlier AAs**
Description Part No. Each
Stainless Steel Nebulizer Assembly 03030352 606
Description Part No. Each
O-Ring 09902005 1Insert 03031812 68Nebulizer Body 03030353 64Front End Cap 03031808 14O-Ring 09902239 1Adjustment Nut 03031460 41Locking Ring 03031456 9Washer 03031802 4O-Ring 09902102 1Spring 03031806 5
/ See chart on page 17* For AAnalyst spectrometers shipped starting Fall 1999** May be used on AAnalyst 200/400. Requires End Cap (00570984)
For Models 4100, 2100, and 1100(B)Description Part No. Each
Stainless Steel Nebulizer Assembly N3110109 1001
Description Part No. Each
O-Ring B0045095 1Insert B0057336 31Nebulizer Body B0152456 88
B0166507 159Front End Cap B0166502 15O-Ring B0148651 3Adjustment Nut B0166505 32
B0057408 41Locking Ring B0166506 13
B0057409 15Washer B0057334 6O-Ring B0057761 2Spring B0057410 5
/ See chart on page 17BA201918
17
161514
131211
BA10987654321
1112
1311
B14 15
2019A
18
1716
12
3 1B
4 5
109
A
8
76
Stainless Steel Nebulizer()
()
()
()
-
Flo
w In
jec
tion
Sa
mp
ling
Su
pp
lies
Ato
mic
Ab
sorp
tion
Flow Injection Sampling SuppliesFlow Injection Analysis and Mercury Systems
21
PerkinElmer pioneered the use of flow injection techniqueswith atomic spectroscopy. The use of flow injection withAA, ICP, and ICP-MS saves time, costs and manpower,while at the same time extending your analytical flexibilityand capabilities.
The overall benefits include:Increased sample throughputReduced reagent consumptionReduced sample volumeAutomated cold vapor mercury determinations using U.S.Environmental Protection Agency-approved methodologyAutomated hydride generation determinationsAutomated analyte preconcentrationMatrix removalAutomated sample dilution and reagent additionEnhanced performance for sampleswith high dissolved solids content
FIMS Tubing DiagramThe Flow Injection Mercury System (FIMS) is an extremelysmall and easy-to-operate atomic absorption instrumentdedicated to trace mercury determination. Based on flowinjection techniques, it is fully automated, fast, and cost-effective. FIMS provides exceptional sensitivity, precision,and detection limits.
Flow InjectionAnalysis Systems (FIASTM)
Flow InjectionMercury Systems (FIMSTM)
FIMS and Autosampler
FIAS 100
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nF
low
In
jec
tio
n S
am
plin
g S
up
plie
sFlow Injection Sampling SuppliesFIAS and FIMS Parts and Supplies
22
Quartz Cell 2 for FI-MHSFor use with the electrically heatedcell assembly or an air-acetyleneflame withsuitable mount.
Quartz Window
Quartz Window AssemblyPart of Quartz Cell 2.
Universal Quartz Cell HolderAllows mounting of the FIAS-100/400Quartz Cell to Models 5100, 3030, 2380,3300, 3110, 3100, and AAnalyst series.
Note: If both NaBH4 and SnCl2 are to be used as reducing agents with FIASsystems configured for Hg/hydride determinations, it is strongly recommendedthat separate mixing manifolds, gas-liquid separators, quartz cells, andrequired tubing and connectors be dedicated for use with eachreducing agent.
See page 25 for a complete listing of fittings, tubing, and flow injection supplies.
Absorption Cell Body
Quartz Window AssemblyKit Includes: Part No. Each
Window B0066549 21Holder B3000243 12
FIMS Source Mercury Lamp
Mercury Lamp ExtractorFor removing mercury lamp.
Silicone SleeveFor FIMS Cell Sample Inlet.
Silicone TubingFor FIMS Cell Exhaust Outlet, 3 m.
Hg Scrubber KitTraps mercury vapor from the FIMS system. Eliminates theneed for an expensive exhaust vent.Recommended by the U.S. EPA.Included with FIMS-100/400.
Hg Replacement Filter
Gas/Liquid SeparatorModular building block-type gas-liquid separatormade from chemically resistant plastic. Anexchangeable PTFE membrane in the screw capof the separator prevents liquid from being carriedinto the quartz cell or ICP torch when working
with strongly foaming samples.(For ICP-MS use B0193772.)
Mixing ManifoldModular building block-type mixing manifold with onemixing channel and three connections; two inlet, and oneoutlet. Made from chemically resistant plastic. Several of theseblocks can be plugged together easilyto create a single unit with enhancedmixing capabilities. Part of B0507957.
Mixing/Separation AssemblyComplete modular unit, consisting of two mixing manifoldswith tubing adapters K and M, a gas-liquid separator with aPTFE membrane, five spare PTFEmembranes, one PTFE tube (110 mmlong), and one PTFE tube (300 mm long).
ChemifoldFor use with Glass Gas/Liquid Separator.
Gas/Liquid Separator Holderfor Glass Separator
Glass Gas/Liquid Separator
PTFE MembraneFor use with the B0507959Gas/Liquid Separator. (pkg. 50)
Plug ConnectorFor connection of the mixing manifoldand gas/liquid separator blocks.
FIAS Cells and Supplies
Part No. Each
B0507486 854
Part No. Each
B0066549 21
Part No. Each
B0507487 140
Part No. Each
B3000350 338
FIMS Cells and Supplies
Part No. Each
B0510487 214
Part No. Each
B0510370 84
Part No. Each
B3000243 12
Part No. Each
B0046948 3
Part No. Each
B3000277 134
Part No. Each
B3000274 107
Gas/Liquid Separator Consumables
Part No. Each
B0507959 147
Part No. Each
B0187258 402
Part No. Each
B0509479 377
Part No. Each
B0193772 204
Part No. Each
B0508306 319
Part No. Each
B0507962 50
Part No. Each
B0507957 504
Part No. Each
B0507960 13
Part No. Each
B0018283 11
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
-
Flow Injection Sampling SuppliesFIAS and FIMS Parts and Supplies
Flo
w In
jec
tion
Sa
mp
ling
Su
pp
lies
Ato
mic
Ab
sorp
tion
23
Magazine for Peristaltic PumpOne wide (>2 mm) tubing channel.
Magazine for Peristaltic PumpTwo narrow (
-
Flo
w I
nje
cti
on
Sa
mp
ling
Su
pp
lies
Flow Injection Sampling SuppliesFIAS and FIMS Tubing Adapters and Connectors
24
Adapters with Internal Threads
Connectors
Type Description Part No. Each
K / L 1/4 in. (6.4 mm)External Screw Thread,K = 1.8 mm o.d. Nipple. B0507918 14L = 2.8 mm o.d. Nipple. B0507920 16
M 1/4 in. (6.4 mm) B0507919 15External Screw Thread,4 mm o.d. Nipple.
N 1/4 in. (6.4 mm) External B0507949 40Screw Thread, 0.7 mm o.d.Pt/lr Capillary Nipple.
Screw Plug B0507921 91/4 in. (6.4 mm)External Screw Thread.
Type Description Part No. Each
A / B 1/4 in. (6.4 mm)Internal Screw Thread,A = 1.8 mm o.d. Nipple. B0193342 12B = 3.3 mm o.d. Nipple. B0506716 40
C 1/4 in. (6.4 mm) B0196850 38Internal Screw Thread,4 mm o.d. Nipple.
E 1/4 in. (6.4 mm) B0196857 38Internal Screw Thread,for the Quartz Cell.
F 1/4 in. (6.4 mm) Internal B0193873 57Screw Thread, 0.7 mm o.d.Pt/lr Capillary Nipple.
G 1/4 in. (6.4 mm) Internal B0501580 71Screw Thread, Two Nipplesto connect tubes to thePreconcentration Accessory.
Type Description Part No. Each
IA Connector with Nipples B0199233 4for 1.7 to 3.2 mmi.d. tubes.
IB Connector with Nipples B0196882 1for 2.4 to 3.2 mmi.d. tubes.
II Connector with 1/4 in. B0196704 3(6.4 mm) InternalScrew Thread.
IIIA T-piece with Nipples B0199035 14for 1.5 to 2.5 mmi.d. tubes.
IIIB T-piece with Nipples B0198201 17for 3.5 to 4.5 mmi.d. tubes.
Screw Connector Tightening ToolFor convenient tightening and looseningof the screw connectors used withPTFE tubing assemblies.
Part No. Each
B0501315 47
Adapters with External Threads
I
EII
II
K
K
FIAS-400
()
()
()
()
-
Flo
w In
jec
tion
Sa
mp
ling
Su
pp
lies
Ato
mic
Ab
sorp
tion
Flow Injection Sampling SuppliesFIAS and FIMS Tubing and Supplies
25
Peristaltic Pump TubingPeristaltic pump tubing has a wall thickness of 0.84 mm unlessnoted otherwise. Part numbers are for a package of 12 pieces.
i.d. (mm) Color Code Part No. Each
0.76 Black/Black B0506058 371.14 Red/Red B0193160 371.52 Yellow/Blue B0193161 372.06 Violet/Violet B0199034 373.18 Black/White B0508310 37
Peristaltic Pump Tubing, Solvent-ResistantWhite/white, 0.84 mm i.d.Resistant to organic solvents. (pkg. 12)
PVC Waste Tubing3 mm i.d. with 1 mm wall thickness,no fittings. Price per meter.
Silicone Tubing1 m x 5 mm i.d., no fittings.
The following are part numbers for PTFE tubing, O-Rings,and screw connectors to prepare tubing assemblies.
PTFE Tubing AssembliesColor
i.d (mm) (Screw Fittings) Length (mm) Part No. Each
1.0 Blue 700 B0191059 29
1.0 Blue 110 B0191058 19
1.0 Blue 300 B0198097 19
1.0 Blue 1000 B0191060 19
1.75 Black 250 B0198099 61
1.75 Black 450 B0198100 61
0.35 White 60 B0501594 34
Flanging ToolUsed with PTFE tubing, screwconnectors, and O-Rings to maketubing assemblies.
Screw ConnectorsColor Description Part No. Each
White For 0.35 mm i.d. PTFE Tubing B0502923 1
Red For 0.5 mm i.d. PTFE Tubing B0181354 1
Green For 0.7 mm i.d. PTFE Tubing B0502924 1
Blue For 1.0 mm i.d. PTFE Tubing B0502925 1
Black For 1.75 mm i.d. PTFE Tubing B0502921 1
Note: These connectors are all the same size.The color code is a universal system to denote the tubing i.d.
O-RingsDescription Part No. Each
For 0.35 - 1.0 mm i.d. Tubing B0507708 1
For 1.75 mm i.d. Tubing B0045472 1
PTFE Tubing (sold by meter)Tubing i.d. Part No. Each
0.35 mm B0506060 3
0.5 mm B0507020 3
0.7 mm B0507021 2
1.0 mm B0029792 2
1.75 mm B0017998 3
Description Part No. Each
200 L B0194048 36500 L B0194049 361000 L B0501000 55
3-D Reaction Coil3-dimensional reactor, 0.35 i.d.(two flanged ends).
Peristaltic Pump Tubing
Part No. Each
B0048139 1
Part No. Each
B0018283 11
Part No. Each
B0507692 62
PTFE Tubing, ScrewConnectors, and O-Rings
Part No. Each
B3000001 198
Sample Loops
Part No. Each
B0501595 64
PTFE TubingPart No. B0198097
()
()
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nF
low
In
jec
tio
n S
am
plin
g S
up
plie
sFlow Injection Sampling SuppliesFlow Injection Amalgamation System
26
Flow Injection Amalgamation SystemProvides increased sensitivity for the determination ofmercury by amalgamation of Hg on a Au/Pt gauze. Mercurycollected is quantitatively released by a controlled, rapidheating of the gauze.
Components Part No. Each
Quartz Tube with Au/Pt Gauze B0193793 395Glass Fiber Filter Holder B0507777 363
May be used in place of drying tubeGlass Fiber Filter, pkg. 20 B0507779 27Drying Tube B0198104 54
5 Wash Flask, 10 mL B0505326 1056 Connector, T-type B0198201 177 Sample Loop, 1000 L B0501000 558 PTFE Tubing B0198099 61
1.75 mm i.d., 250 mm length
8 PTFE Tubing B0198100 611.75 mm i.d., 450 mm length
Silicone Tubing B0018283 115 mm i.d., 1 m
Silicone Tubing B0070126 93 mm i.d., 1 m
Air Filter B0502706 15One-way Valve B0198111 96
1
Amalgamation System and Supplies
Part No. Each
B0191090 5100
8
5
4
5
2
96
3
8
5
1
7
6
1
2
3
5
III4
6
7
8
9
III
()
()
-
Flo
w In
jec
tion
Sa
mp
ling
Su
pp
lies
Ato
mic
Ab
sorp
tion
Flow Injection Sampling SuppliesFlow Injection Furnace Supplies
27
The direct coupling of flow injection with a graphite furnaceatomic absorption automates on-line element preconcentrationin the graphite tube, improving detection limits for the hydride-forming elements and for mercury by a factor of up to 500.
FIAS-Furnace Coupling KitFor coupling a FIAS-400 with a 4110 ZL, AAnalyst 400(with HGA-900), AAnalyst 600, AAnalyst 700, AAnalyst800, or SIMAATM 6100/6000 Graphite Furnace System.The kit consists of a sample transfer tube, a quartz pipettetip, a 50 mL bottle Iridium standardsolution, and a FIAS-Furnace user guide.
FIAS-Furnace SampleTransfer Tube*
Quartz Pipette Tip*20 mm. (pkg.1)
Silicone Tube*1 m.
* Included in the FIAS-Furnace Coupling Kit (B3140255)
FIAS-Furnace Coupling Kit and Supplies
SampleCapillary
Graphite Tube
Gas/Liquid-Separator
ArgonNaBH4
HCl
P1
P2
Waste
FIA Valve
Flow Diagram for FIAS-Furnace Coupling
Part No. Each
B3140255 654
Part No. Each
B0509612 119
Part No. Each
B0510032 35
Part No. Each
B0029796 4()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nF
low
In
jec
tio
n S
am
plin
g S
up
plie
sFlow Injection Sampling SuppliesFlow Injection Preconcentration Kit and Supplies
28
PTFE Tubing AssembliesFlow Injection SamplingValves and Supplies
Components Part No. Each
FI Sampling Valve, 5-Port B0507914 714FI Sampling Valve, 8-Port B0509095 1418
Valve Dismantling Tool B0509590 4Threaded Plug B0500695 468
To close off port on5-port valve
Peristaltic pump tubing has a wall thicknessof 0.84 mm unless noted otherwise.
Components Part No. Each
Tubing (pkg. 12) B0193161 37
1.52 mm i.d., Yellow/Blue
Tubing (pkg. 12) B0506058 37
0.76 mm i.d., Black/Black
Tubing (pkg. 12) B0507692 62
1 mm i.d., White/WhiteResistant to organic solvents
Components Part No. Each
C18 Preconcentration Column B0504047 689
PTFE column packed with silica-immobilizedC18 Material. (Pkg.10)
XAD-8 Preconcentration Column B0504048 689
PTFE column packed with XAD-8 Material. (Pkg.10)
Cr Preconcentration Column B0509561 631
Alumina column for speciation ofCr (III) and Cr (Vi). (Pkg.10)
In the PTFE tubing assemblies describedbelow, the numbers in parentheses refer tothe length of the tubing assembly and thenumber of flanged ends with screw fittings.
Components Part No. Each
PTFE Tubing Assembly B0191059 29
Carrier or reagent container to peristalticpump tubing, 1 mm i.d. (700 mm x 1 flanged end)
PTFE Tubing Assembly B0191058 19
Manifold to manifold and to tubing adapter C,1 mm i.d. (110 mm x 2 flanged ends)
PTFE Tubing Assembly B0501594 34
Valve to preconcentration column,0.35 mm i.d. (60 mm x 2 flanged ends)
PTFE Tubing Assembly B0501595 64
3-dimensional reactor, 0.35 mm i.d.(two flanged ends)
Components Part No. Each
Tubing Adapter A B0193342 12
Connects thin (1 to 2 mm i.d.) peristalticpump tubing with the PTFE tubing screw fittings
Tubing Adapter C B0196850 38
Connects to 3 mm waste tubing
Tubing Adapter G B0501580 71
For peristaltic pump tubing to mergechelate and sample streams
Tubing Connector Type II B0196704 3
Connects two PTFE tubing screw fittings
Peristaltic Pump Tubing
Preconcentration Columns
2
7
8
9
1
1
1
3
4
5
6
Tubing Adapters and Connectors
A
C
G
II
A
A3
A
A
39
55
44
GC
II6
7
8 C
2
1
()
()
()
()
()
-
29
Rely on PerkinElmer graphitefor consistent analytical results.
Every sample. Every day.
We Start With an Exclusive Grade of GraphiteThe production of high-quality graphitecomponents requires stringent quality control.Selection and careful control of raw materials areextremely important.
The composition and the microstructure of thebase graphite material determines the resistivityof the tube and its heating characteristics. Toensure high quality and consistency, a specifichigh-density base graphite material has beendeveloped for use with PerkinElmer graphitefurnace systems. This base graphite material isused exclusively for the manufacturing ofPerkinElmers graphite components.
Trust Your Analysis toGenuine PerkinElmer Graphite
Our Tubes Are Manufacturedand Tested to the HighestQuality SpecificationsDuring manufacturing, a comprehensivequality testing program includingextensive mechanical, electrical,thermal, and analytical testingprocedures is strictly followed.
Each lot of graphite tubes is tested todemanding specifications for lifetime,sensitivity, and precision.
Extensive testing ensures that all graphitecomponents shipped by PerkinElmerprovide consistent lot-to-lot performance.
Our Pyrolytic Coating Designis Critical to AchievingHigh PerformanceThe specified thickness of pyrolytic coatingapplied to PerkinElmer graphite improvesthe total resistance of the graphite tube andthe temperature distribution within thetube. Improper pyrolytic coating canshorten tube lifetime dramatically.
The microstructure and density of thesurface are important parameters for theatomization kinetics of analyte elements.Irreproducible surface qualities will causechanges in the optimal drying, pyrolysisand atomization temperatures, peak shapeand characteristic mass. PerkinElmerscoating specification and quality controlensure consistency from tube to tube.
You Can Depend onOur Extensive ExperiencePerkinElmer has over three decadesof experience in the design anddevelopment of graphite furnacesystems and materials. Years ofPerkinElmer development haveyielded the best possible graphitefor atomic absorption.
Any other graphite has not beenoptimized for use with PerkinElmerinstruments and may yieldinaccurate analytical results.
Graphite FurnaceGraphite Tubes and Supplies
-
Graphite FurnaceGraphite Tubes and Supplies
30
Do Not Accept ImitationsGraphite components offered by other companiesoften refer to the PerkinElmer part, implying that thesecomponents are made from the same material and provideequivalent performance. This is misleading, as theseimitation components are not made from the samebase graphite material, nor are they tested to the samedemanding quality control specifications. The differentbase graphite material will alter the temperaturecalibration, the heating rates, and the performancecharacteristics.
Rely on Genuine PerkinElmer GraphiteTodays analysts expect exceptional analytical performancefrom their graphite furnace atomic absorption spectrometers.That performance must be stable and reproducible fromday to day with respect to sensitivity (characteristic mass),accuracy, and precision.
The graphite tube, the heart of the graphite furnace, playsa vital role in the overall stability of an analysis. In orderto assure stable analytical conditions from one atomizationcycle to the next, and from graphite tube to graphite tube,
all graphite parts contacts, tubes, and platforms must be under strict quality control by both the instrumentmanufacturer and the graphite manufacturer. PerkinElmergraphite components continue to set the industry standardfor quality.
The proper performance, maintenance, and serviceabilityof your graphite furnace system can be assured onlythrough the use of genuine, high-quality PerkinElmergraphite components.
How is High-Quality Graphite Manufactured? Select carefully chosen raw materials that are exclusive to PerkinElmer
Mill and mix the components with precision
Utilize the proper pressing techniques
Employ the correct heat treatments at carefully selected times
Purify materials at multiple times throughout the process
Apply special coating technology for pyrolytic products
Test and qualify graphite against rigorous PerkinElmer standards
Machine patented PerkinElmer designs using specialized techniques
-
Gra
ph
ite F
urn
ac
e Tu
be
s an
d S
up
plie
sA
tom
ic A
bso
rptio
nGraphite Furnace Tubes and Supplies
HGA Graphite Contact Cylinders, Tubes, and Supplies
31
The graphite contact cylinders used in the HGA GraphiteFurnace are engineered for a precise fit so that variationsin electrical contact which might affect the analyticalperformance are reduced to a minimum. The graphitecontacts are shaped so that they completely encase thegraphite tube. Thus, the graphite tube is located in adefined inert environment, which ensures uniformheating conditions and long tube lifetime.
Contact Cylinders for HGA-500/400 FurnacesIncludes left-hand Contact, right-hand Contact, Shield Ring.
Description Part No. Each
5 sets B0180363 492
Contact Cylinders for Zeeman HGA FurnacesIncludes left-hand Contact, right-hand Contact.
Description Part No. Each
1 set B0116823 1305 sets B0180361 617
Contact Cylinders forHGA-900/850/800/700/600/300 FurnacesIncludes left-hand Contact, right-hand Contact, Shield Ring.
Description Part No. Each
1 set B0128495 1075 sets B3130086 506
Contact Cylinders Removal ToolDescription Part No. Each
For HGA-300/400/500/600/700/800 Furnaces B0098258 536For HGA-600 Zeeman Furnaces B0127431 472For AAnalyst 700 and HGA-850/900 B3121301 320
Graphite Tube Alignment ToolsDescription Part No. Each
For Non-Zeeman Furnaces B0080112 80For Zeeman HGA Furnaces B0120242 80
The Lvov Platform is a small plate of solid pyrocoatedgraphite that is inserted into the graphite tube. It has a slightdepression in the center which can accommodate up to 50 Lof solution. The function of the Lvov Platform is to isolatethe sample from the tube walls to allow more reproducibleatomization of the sample through indirect heating. Theplatform heats primarily by the radiation given off from thetube walls. Sample vaporization and atomization occur afterthe tube reaches a steady-state temperature.
Use of the Lvov Platform provides:
Vaporization into a higher temperature gas atmosphereproducing more free atoms, which reduce interferences
Longer tube life because aggressive samples are onlyin contact with the solid pyrolytic graphite platform
Description Part No. Each
5-pack B0137112 10420-pack B3001256 39450-pack B0109324 935100-pack N3110145 1765
Lvov Platforms
Contact Cylinders
For Non-Zeeman FurnacesPart No. B0080112
For Zeeman HGA FurnacesPart No. B0120242
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nG
rap
hit
e F
urn
ac
e T
ub
es
an
d S
up
plie
s
32
Graphite Furnace Tubes and SuppliesHGA Graphite Contact Cylinders, Tubes, and Supplies
High-purity compounds minimizethe risk of contamination
Optimum graphite furnace programcan be used due to reducedanalyte volatility
Convenient, ready-to-use
Modifier Concentration Volume (mL) Part No. Each
Mg(No3)2 1% Mg (as nitrate) 100 B0190634 71Pd 1% Pd (as nitrate) 50 B0190635 249NH4H2PO4 10% NH4H2PO4 100 N9303445 101
Pyrocoated Graphite Tubes (Grooved)Internally grooved to accept Lvov Platforms.
Description Part No. Each
5-pack B0137111 23720-pack B3001254 90050-pack B0109322 2131100-pack N3110146 4026
HGA Furnace Mirror
Graphite tubes with integrated platforms are machined fromone piece of graphite and are totally pyrocoated, providingexceptional tube-to-tube reproducibility.
The spherically shaped platformaccommodates up to 50 L of sample.
Graphite tubes with integrated platforms:
Provide STPF conditions for volatile and nonvolatile refractoryelements due to the significantly higher heating rates of tubeand platform, which can be used for all elements
Offer an extra measure of convenience versus manuallyinserting a separate platform
Provide longer life with many aggressive sample matrices,such as concentrated acids
Pyrocoated Graphite Tubes with Integrated PlatformsDescription Part No. Each
5-pack B3001262 31720-pack B3001264 1138100-pack N3110149 5400
Pyrocoated Graphite Tubes*Description Part No. Each
5-pack B0105197 21310-pack B0135653 40320-pack B3000342 76550-pack B0091504 1808
Description Part No. Each50-pack B0070699 965
Matrix Modifiers forGraphite Furnace AA
Pyrocoated Graphite Tubes (Grooved)for use with Lvov Platforms
Cross-section of the PerkinElmer HGA graphite tubewith manually inserted Lvov platform.
Part No. Each
B0080259 83
Cross-section of the PerkinElmer HGA graphite tubewith integrated platform.
Uncoated Graphite Tubes*
Pyrocoated Graphite Tubeswith Integrated Platforms
* Not compatible with Lvov Platforms.
* Not compatible with Lvov Platforms.
Uncoated Graphite Tubes Part No. B0070699
Pyrocoated Graphite Tubes withIntegrated Platforms Part No. B3001262
()
()
()
()
()
()
-
Gra
ph
ite F
urn
ac
e Tu
be
s an
d S
up
plie
sA
tom
ic A
bso
rptio
nGraphite Furnace Tubes and Supplies
HGA Graphite Cooling Systems and Quartz Windows
33
HGA Circulatory Cooling System for HGA-800/850/900
Voltage Part No. Each
115 V, 60 Hz B3001124 4323230 V, 50/60 Hz B3001123 4323
Glycerol(85% for cooling systems), 1 L
The HGA Graphite Furnace Assembly is sealed at both endswith easily removable quartz windows. This closed-furnacedesign is a prerequisite for controlled and reproducibleinternal analytical conditions.
Model Window Part No. Each
AAnalyst 700/HGA-850/900 Left- and Right-hand B0080850 109
Model Window (small window) Part No. Each
Zeeman 5X00 Right-handZeeman 3030 Right-handHGA-300/400/500 Left- and Right-handHGA-600/700 Right-handHGA-800 Left-hand
B0066549 21
Model Window (large window) Part No. Each
Zeeman 3030, 5X00 Left-handHGA-600/700 Left-handHGA-800 Right-hand
B0115576 43
Components Part No. Each
O-Ring B0047209 2Gasket* B0071145 1Window B0066549 21Window B0115576 43Gasket** B0104342 2
* Use B0147153 on the HGA-800** Use B0196825 on HGA-600s and HGA-700s installed after May 1990
54321
Quartz Windows
Quartz Window Components
1
2
3
4
5
Circulatory Cooling System
Part No. Each
B3141064 29
HGA Circulatory Cooling SystemPart No. B3001124
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nG
rap
hit
e F
urn
ac
e T
ub
es
an
d S
up
plie
sGraphite Furnace Tubes and SuppliesTHGA Graphite Contact Cylinders, Tubes, and Supplies
34
The graphite contact cylinders are engineered for a precisefit so that variations in electrical contact which mightaffect the analytical performance are reduced to aminimum. Contact cylinders with a modified injectionport area help to minimize condensation and improveanalytical performance with difficult matrices.
Standard THGA Contact CylindersDescription Part No. Each
1 pair B0504035 1745 pairs B0504036 824
Modified THGA Contact CylindersFor improved analytical performance with samples thathave a high concentration of dissolved salts or matriceswith a high boiling point with transversely heatedgraphite furnaces.
Description Part No. Each
1 pair B3002103 1875 pairs B3002102 886
Accessories and Spare PartsDescription Part No. Each
O-Ring (behind contact cylinder, front and back) B0500748 1Contact Cylinder Removal Tools B3120405 402
Standard THGA Graphite Tube
PerkinElmers unique, transversely-heated graphite tube includes anintegrated platform. The exceptionallyuniform temperature distributionobtained with transverse heatingsignificantly reduces or eliminatescondensation of the sample matrix
components and memory effects, and improves theatomization efficiency for refractory elements.
Description Part No. Each
5-pack B3000641 60020-pack B0504033 2156100-pack N3110147 10200
Standard THGA Graphite Tube with End Cap*
For improved characteristicmass with volatile andmedium refractory elementssuch as Ag, As, Cd, Co, CrCu, Pb, Se, and Tl, the THGAgraphite tubes with end capsare recommended.
Improved detection limits for volatile and mediumrefractory elements
Faster drying for complex matrices due to enlargeddosing hole
Description Part No. Each
5-pack B3000653 61220-pack B3000655 2200
* Not recommended for refractory elements such as V or Ba.
UltraClean THGA Graphite TubeFor the lowest possible detection limits, residual contaminantlevels may not be low enough to meet your requirements. Forthe most demanding analyses, PerkinElmer offers UltraCleanTHGA graphite tubes delivering exceptionally low levels ofcontamination due to advanced high-temperature gas-phasecleaning procedures. UltraClean graphite tubes offerunmatched analytical advantages for special applicationssuch as the determination of extremely low traces of Na,Ca, Fe, Cr, and Ni in ultra-clean reagents used in thesemiconductor industry, and ultra-trace analyses ofenvironmental, clinical, or food samples.
Key Benefits
UltraClean THGA graphite tubes have the lowest possiblecontamination levels due to extensive high-temperaturegas-phase cleaning procedures
UltraClean THGA graphite tubes are tested and specifiedfor blank levels of Cr, Ni, V, Mo, Ti (
-
Gra
ph
ite F
urn
ac
e Tu
be
s an
d S
up
plie
sA
tom
ic A
bso
rptio
nGraphite Furnace Tubes and SuppliesTHGA Graphite Contact Cylinders, Tubes, and Supplies
35
High purity compounds minimize the risk of contamination Optimum graphite furnace program can be used due to
reduced analyte volatility
Convenient, ready-to-use
Modifier Concentration Volume (mL) Part No. Each
Mg(No3)2 1% Mg (as nitrate) 100 B0190634 71Pd 1% Pd (as nitrate) 50 B0190635 249NH4H2PO4 10% NH4H2PO4 100 N9303445 101
Circulatory Cooling System for usewith THGA Furnace Systems230 V, 50/60 Hz.
Quartz Window for the THGA
O-RingFor Furnace Window.
Rinse Funnel for Fume Extraction SystemUsed to aspirate water.
Spare Graphite Tip for the Fume Extraction System(1 piece).
THGA Furnace MirrorUsed to optimize drying temperaturesand times.
THGA Graphite Tube Pliers
Matrix Modifiers forGraphite Furnace AA
Spare Parts and Supplies
Part No. Each
B0198072 3890
Part No. Each
B0501236 13
Part No. Each
B0198005 120
Part No. Each
B0508836 13
Part No. Each
B0506722 24
Part No. Each
B0851900 85
Part No. Each
09907925 8
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nL
ab
ora
tory
Pro
du
cts
Laboratory ProductsFilters, Regulators, and Supplies
36
Filters
Balston Air Filter Assembly Type A-82Specifically designed toremove water, oil, and dirtparticles down to 0.6 micronsin diameter from compressedair lines. It is recommended foruse with oil-type compressors,and for removing moisture anddirt particles from air suppliedby oil-less compressors.
Replacement Air Filter
Wilkerson Air Dryer FilterProvides clean air for burnercontrols used with AAspectrometers. It removesentrained water, oil, and wateraerosols, and solid particlesfrom compressed air lines. Thepressure regulator reduces theair pressure, which decreasesthe relative humidity of theair and prevents further
condensation. The final filter removes aerosols and particleswhich are small enough to pass through the pre-filter. Oil,if present, is collected on the coalescing-type final filter anddrips to the bottom of the bowl. The assembly consists of ashut-off valve, a pre-filter with automatic drain, a pressurereducing regulator with pressure gauge, a final filter, and afinal filter indicator.
Max Inlet Pressure: 150 psig
Replacement FiltersReplacements (Pre-filter) Part No. Each
Filter Elements 09923464 19Filter Bowls N9302199 25
Replacements (Final Filter) Part No. Each
Filter Elements 09907120 47Filter Bowls N9302199 25Bowl O-ring Kit N9302197 45
Balston 95A AcetyleneIncludes a Balston GradeBQ filter cartridge to removeliquid and solid contaminantsfrom the acetylene supply to99.99% at 0.01 micron.
Max Working Pressure: 15 psig
Acetylene ReplacementFilter Cartridge
Parker Balston 73-099 AA Gas PurifierA wall-mounted system designedto purify the compressed air andacetylene gases used in atomicabsorption. It consists of twoindependent filtration systems,one for compressed air andone for acetylene. The unitalso has a flashback arrestoron the acetylene line and apressure regulator on thecompressed air line.
The two-stage air filtrationassembly consists of a Balston Grade DX coalescing filter anda Balston Grade BX coalescing filter. Together these filtersremove oil, water, and particulate contamination (99.99% at0.01 micron) from the compressed air supply.
Replacement Cartridges1st Air Filter Part No. Each
Replacement Cartridges N9301710 18Replacement Seal Sets N9301712 17
2nd Air Filter Part No. Each
Replacement Cartridges N9301711 18Replacement Seal Sets N9301712 17
Acetylene Filter Part No. Each
Replacement Cartridges N9301714 12Replacement Seal Sets N9301715 10
Part No. Each
N0580531 281
Part No. Each
N0582251 42
Part No. Each
N9301399 312
Part No. Each
N9301714 12
Part No. Each
N9301398 1008
Part No. Each
00470652 555
()
()
()
()
()()
()
()
()
()
()
-
La
bo
rato
ry Pro
du
cts
Ato
mic
Ab
sorp
tion
Laboratory ProductsFilters, Regulators, and Supplies
37
Matheson Flashback ArrestorBecause acetylene is an extremely unstable gas, userscan experience flashbacks at the instrument burner head.The flash arrestor prevents these potentially dangerousflashbacks from reaching the regulator or cylinder.
Acetylene Max Operating Pressure: 15 psig
Positive shut-off of gas checks the reverse flow under allconditions. Also stops gas supply when a flashback occurs.
Hose AssembliesHose assemblies for connecting fuel, air, and nitrous oxidefrom supply to instrument.
Description Part No. Each
Acetylene, red, 3.7 m (12 ft.) long 00570559 80Air/Argon, black, 3.7 m (12 ft.) long 00570567 80Nitrous Oxide, blue, 3.7 m (12 ft.) long 00470258 116
Filter Cartridge for Fume Extraction Separator Trap(pkg. 50)
Instrument Filters
Description Part No. Each
Filter for AA 100/300 09995097 21Filter for AA 200/400/600/700/800 B0501696 21Filter for AA 600/700/800 (80x80) B0502706 15
SIMAA 6100/6000Rear filter. (pkg. 1)
Square Filter Pads4100 ZL/4110 ZL, side andback filters. (pkg. 1)
Aqueous and organic solutions as well as acids (including HF)can be easily dispensed without the risk of sample contaminationwhen using the high-precision MiniDispenser.
Bottle Holder PP-250Used to stabilize 250 mLplastic bottles such as suppliedby Suprapur andOptima chemicals.
MiniDispenserPreassembled and tested.Includes GL45, S40, and38-430 bottle adapters.
Replacement Valve KitFor replacing MiniDispenser valves.
Part No. Each
N9300068 312
Hose Assemblies
Flash Arrestor
Acetylene, RedPart No. 00570559
Air/Argon, BlackPart No. 00570567
Instrument Filters
Part No. Each
B0509065 37
Part No. Each
B0502706 15
Part No. Each
B0501252 3
MiniDispenser
Part No. Each
B0511806 59
Part No. Each
B0511778 201
Part No. Each
B0511779 130
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,visit www.perkinelmer.com/supplies
-
Ato
mic
Ab
sorp
tio
nL
ab
ora
tory
Pro
du
cts
Laboratory ProductsFilters, Regulators, and Supplies
38
Venting SystemA venting system isrequired to remove fumesand vapors from the burnercompartment of atomicabsorption instruments.Includes exhaust hood,adapter, and blower.
Description Part No. Each
Blower and Vent Assembly 03030406 1218Exhaust Hood 03031910 236
Acetylene Regulator
Includes an adapterso that the pressureregulator can beconnected to cylindersrequiring either CGA 300or CGA 510 fittings anda connector for attachingthe fuel hose assemblysupplied with theinstrument. Includeshose assembly.
Max Inlet Pressure:400 psig
Air Regulator
Regulator to cylinderCGA no. 590. Includeshose assembly.
Max Inlet Pressure:3000 psig
Argon/Nitrogen Regulator
Can be used with Argonor Nitrogen and hasa CGA 580 fitting. Acolor-coded hose with1/4-inch SWAGELOK
fittings is also included.
Max Inlet Pressure:3000 psig
Nitrous Oxide Regulator
For use with gascylinders with a CGA 326connection. Providespressure control from350-520 kPA (50-75 psig)and contains an integralthermostatted heater toprevent freezing ofthe regulator diaphragm.A color-coded hose withsuitable connectors ateach end is suppliedwith the regulators toprovide connection to theinstrument gas controls.
Part No. Each
03030284 446
Part No. Each
03030204 848
Regulators
Part No. Each
03030106 446
Part No. Each
03030264 446
Venting System
Note: Does not include ducting.PerkinElmer Service Engineers arenot permitted to install this unit.
()
()
()
()
()
-
PerkinElmers expertise in the design andmanufacture of light sources for atomicabsorption spectrometers traces back toour original hollow cathode lamps, developednearly 40 years ago.
Genuine PerkinElmerHollow Cathode Lamps
forAtomic Absorption
39
Lamps for Atomic AbsorptionLumina Hollow Cathode Lamps
PerkinElmer manufactures a full range of single-element and multi-element hollow cathode lampsand high-intensity electrodeless discharge lamps forthose elements for which they are more effective.
Every genuine PerkinElmer Lumina lamp is designedfor use with, and tested on, our spectrometers to assurecompatibility and the highest performance. To prolongthe life of a Lumina hollow cathode lamp (HCL), weproduce lamps with larger internal volume so thata greater supply of fill gas at optimum pressure isavailable. The larger the lamp, the greater the inertgas volume and the longer the lamp lifetime.PerkinElmer offers a wide range of single-element andmulti-element HCLs, which are ideal for determiningmost elements by atomic absorption spectroscopy.
For the Widest Selection of ElementsThe basic components of a hollow cathode lamp (HCL) are a sealed glasscylinder filled with an inert gas (argon or neon), an anode, a cathode, andeither glass or quartz end window. The cathode is a hollow cylinder ofthe element whose spectrum is to be produced, or in some cases, an alloyor carefully selected mixture of metals which do not spectrally interfere.Hollow cathode lamps emit light by the following process: The fill gas isionized when an electrical potential is applied between the anode andthe cathode. The positively charged ions collide with the negativelycharged cathode and dislodge individual metal atoms in a process knownas sputtering. These sputtered metal atoms are excited throughimpact with fill gas ions, and light of the specific wavelengths for thatelement is emitted when the atom decays from the excited state backto the more stable state.
PerkinElmer Exclusive 6/24 WARRANTY*Lumina Hollow Cathode Lamps1. We warrant that during the first six months or after 5,000 milliampere-hours of operation,
whichever comes first, from initial date of shipment, the lamps will meet or exceed theintensity and absorption specifications to which all new lamps are tested.
2. All our hollow cathode lamps are warranted to light and emit the spectra of the elementindicated for two years or 5,000 milliampere-hours of operation from the date of theshipment, whichever comes first.
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.* The lamp warranty is void for lamps which sustain physical damage or are operated at power
levels substantially above or below the power level recommended on the lamp label. The lampwarranty may vary in different countries.
Features and Benefits Long Life: PerkinElmers larger
lamp volume results in longer
lamp lifetime
Automation: PerkinElmer codedlamps allow automatic setup
Easy Installation: Its as simpleas sliding the lamp into the
instruments lamp bracket
or turret
Timers: Each Luminahollow cathode lamp includes
a milliampere-hour timer in its
base to monitor lamp usage
Complete Compatibility:Lumina hollow cathode lamps
can be used with PerkinElmers
entire range of atomic absorption
spectrometers
Testing: Every lamp is thoroughlytested before leaving the factory
Quality: Carefully selectedmaterials used in the
manufacturing of our lamps
avoid spectral interference
Design: Our design provides youwith the low detection limits
needed for your most difficult
determinations
Selection: PerkinElmer offersa wide selection of single-element
and multi-element lamps
Easy To Order: Its easy to findthe right lamp for your analytical
needs simply use the selection
charts on page 40
Warranty: The performance ofevery PerkinElmer lamp is
fully warranted
-
Ato
mic
Ab
sorp
tio
nL
am
ps
for
Ato
mic
Ab
sorp
tio
nLamps for Atomic AbsorptionLumina Hollow Cathode Lamps
40
Lumina coded hollow cathode lamps are available in twoseries: with and without an Intensitron adapter cable.
Series N30501XX and N30502XX Lumina lampsdo not include an Intensitron adapter cable and aredesigned to be used with PerkinElmers AAnalystTM
series of instruments.
Series N30503XX and N30504XX Lumina lampsinclude an adapter cable that allows the lamps to berecognized by the following instruments: SIMAATM
6100/6000, 5100 (PC), 4110 ZL, 4100, 4100 ZL, 3300,2100, and 1100(B).
Lumina hollow cathode lamps may also be used withall earlier AA spectrometers that do not have automaticcode reading capability by using an appropriateadapter cable (refer to Adapter Cable on page 44).
Lumina LampLumina Plus Intensitron
Element Element Lamp AdapterName Symbol Part No. Each Part No. Each
Aluminum Al* N3050103 483 N3050303 573
Antimony Sb N3050170 573 N3050370 700
Arsenic As N3050105 700 N3050305 828
Barium Ba* N3050109 611 N3050309 738
Beryllium Be* N3050110 802 N3050310 930
Bismuth Bi N3050111 573 N3050311 675
Boron B* N3050108 636 N3050308 764
Cadmium Cd N3050115 547 N3050315 675
Calcium** Ca N3050114 509 N3050314 636
Chromium Cr N3050119 483 N3050319 611
Cobalt Co N3050118 420 N3050318 547
Copper*** Cu N3050121 420 N3050321 509
Dysprosium Dy* N3050122 483 N3050322 663
Erbium Er* N3050123 483 N3050323 663
Europium Eu* N3050124 483 N3050324 611
Gadolinium Gd* N3050129 483 N3050329 611
Gallium Ga N3050128 509 N3050328 611
Germanium Ge* N3050130 573 N3050330 700
Gold Au N3050107 573 N3050307 700
Hafnium Hf* N3050133 509 N3050333 663
Holmium Ho* N3050135 599 N3050335 663
Indium In N3050137 547 N3050337 636
Iridium lr N3050138 802 N3050338 930
Iron Fe N3050126 420 N3050326 509
Lanthanum La* N3050141 636 N3050341 663
Lead Pb N3050157 611 N3050357 738
Lithium Li N3050142 509 N3050342 636
Magnesium** Mg N3050144 483 N3050344 611
Manganese Mn N3050145 509 N3050345 636
Mercury Hg N3050134 547 N3050334 675
Molybdenum Mo N3050146 483 N3050346 573
Neodymium Nd* N3050150 483 N3050350 663
Nickel Ni N3050152 420 N3050352 509
Niobium Nb* N3050149 483 N3050349 573
Palladium Pd N3050158 611 N3050358 738
* This element requires a nitrous oxide-acetylene flame.** To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp
with quartz window.*** To measure secondary lines below 230 nm, choose the Cu/Fe/Mn/Zn lamp
with quartz window.
Lumina Lamps and Lamps with Adapters
() ()
-
La
mp
s for A
tom
ic A
bso
rptio
nA
tom
ic A
bso
rptio
nLamps for Atomic Absorption
Lumina Hollow Cathode Lamps
41
Lumina LampLumina Plus Intensitron
Element Element Lamp AdapterName Symbol Part No. Each Part No. Each
Phosphorus P* N3050155 738 N3050355 866
Platinum Pt N3050162 675 N3050362 802
Potassium K N3050139 509 N3050339 611
Praseodymium Pr* N3050161 599 N3050361 663
Rhenium Re* N3050165 483 N3050365 759
Rhodium Rh N3050166 675 N3050366 802
Ruthenium Ru N3050168 738 N3050368 866
Samarium Sm* N3050174 490 N3050374 663
Scandium Sc* N3050171 573 N3050371 700
Selenium Se N3050172 611 N3050372 738
Silicon Si* N3050173 547 N3050373 675
Silver Ag N3050102 483 N3050302 573
Sodium Na N3050148 547 N3050348 675
Strontium Sr N3050176 547 N3050376 675
Tantalum Ta* N3050177 483 N3050377 611
Tellurium Te N3050180 611 N3050380 738
Terbium Tb* N3050178 547 N3050378 663
Thallium Tl N3050183 547 N3050383 675
Thulium Tm* N3050184 636 N3050384 764
Tin Sn N3050175 547 N3050375 675
Titanium Ti* N3050182 420 N3050382 547
Tungsten W* N3050187 445 N3050387 547
Vanadium V* N3050186 445 N3050386 573
Ytterbium Yb* N3050190 509 N3050390 663
Yttrium Y* N3050189 483 N3050389 611
Zinc Zn N3050191 573 N3050391 700
Zirconium Zr* N3050192 445 N3050392 573
*This element requires a nitrous oxide-acetylene flame.
() ()
See page 4 for ordering information.
For the most current product listing,visit w