Pellet Cooling and Crumbling
by
Fred J. Fairchild, P. E.
Professor
Department of Grain Science and Industry
Kansas State University
Manhattan, Kansas
![Page 2: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/2.jpg)
Pellet Cooling/Drying
A dynamic process that involves
simultaneous heat & mass transfer
between the pellets and the cooling air.
![Page 3: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/3.jpg)
Pellet cooling occurs as a result of both evaporative and convective cooling
Evaporative cooling is the transfer of water in the product to the air, and at the same time cooling occurs.
Convective cooling depends on the temperature difference between the pellets and the air, pellet surface area, and heat transfer coefficient.
Pellet Cooling/Drying
![Page 4: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/4.jpg)
Requirements: • Effective cooling of a range of products
• Moisture removal for safe storage
• Avoid under-drying ($$$)
• Reliable operation
• Gentle product handling
• No condensation in exhaust ducts
• Fines removal from exhaust air
• Improve/maintain pellet quality
Pellet Cooling/Drying
![Page 5: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/5.jpg)
Cooler Performance Variables
• Air temperature
• Air relative humidity
• Air flow
• Pellet temperature
• Pellet moisture content
• Residence time
• Pellet size & density
• Pellet quality
• Cooling bed depth
• Pellet bed uniformity
• System design
![Page 6: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/6.jpg)
Ambient & Product Conditions
• Air Temperature…
• Air Relative Humidity…
• Pellet Temperature…
• Pellet Moisture…
• Air flow…
![Page 7: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/7.jpg)
Pellet Diameter/Pellet Density
↑ Pellet Diameter = ↑ Airflow/Residence Time
↑ Pellet Density = ↑ Airflow/Residence Time
Pellet
diameter, mm
Airflow,
m3/hr
Residence
time, min
2 1,200 6-8
4 1,500 8-10
6 1,600 10-12
8 1,600 12-14
12 1,800 14-16
![Page 8: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/8.jpg)
Pellet Quality • Pellet fines impede air passage through the
pellet bed (↑ static pressure).
• Reduce bed depth
• May need to reduce airflow rate to prevent
fines from being pulled into the cooling duct
• Cooling effects on pellet quality
Uneven cooling
Inadequate cooling
Cooling to fast
![Page 9: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/9.jpg)
Bed Depth/Uniformity
![Page 10: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/10.jpg)
Bed Depth/Uniformity
The deeper the pellet bed depth…
… the higher the final pellet temperature
… the lower the final pellet moisture
↑ Pellet bed depth = ↑ air-pellet contact time = ↓ CFM = ↑ static pressure
![Page 11: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/11.jpg)
Vertical Cooler
Cooling Zone
Warm, Moist
Product In
Cool, Dry
Product Out
Drying Zone
Simple design
Small foot print
Ease of operation
↑ Airflow
↑ Convective cooling
Less flexible (bed depth)
Bridging problems
![Page 12: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/12.jpg)
Vertical Cooler – Cross Flow
Maximum Air Velocity = 350 feet per minute
![Page 13: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/13.jpg)
Horizontal Cooler
Horizontal CoolersWarm ,
Moist
product in Drying Zone
Cooling Zone
Cool, Dry product
out
Single or Double Pass
Low Height
High Capacity
Flexible operation
Ineffective at beginning and
end of run
![Page 14: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/14.jpg)
Horizontal Cooler
2-Pass Horizontal
Cooler
Pellets
Pellets Air Air
Air
Air Velocity
4000 feet/min.
Air Velocity
600 feet/min.
Air
Requirements
450 +/-
CFM/Ton
![Page 15: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/15.jpg)
Compact footprint.
Low maintenance.
Lower CFM of air/ton
Higher HP required
Counter Flow Cooler
![Page 16: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/16.jpg)
Counter Flow Cooler
Drying Zone
Cooling Zone
Warm, Moist
Product In
Cool, Dry
Product Out
Counter Flow
Cooler
Air Requirements
350 +/-
CFM/Ton
![Page 17: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/17.jpg)
Counter Flow Cooler
![Page 18: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/18.jpg)
Air System Flow
Cooler Cyclone
Separator
Airlock
Fan
Air Velocity
4000 fpm min.
![Page 19: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/19.jpg)
System Design
• Cooler air systems should be designed using the correct amount of air (cfm/tph) for the type of cooler used.
• The recommended air velocity in the duct should be 4000 ft/min in order to keep the inside surface of the duct clean
• Fan design, rotation, speed, & belt slippage
• Check for leaks in ductwork, blockage in ducts, or
if the damper is closed
![Page 20: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/20.jpg)
Trouble Shooting Cooler Operation and Performance
What Do I Do Now?
Temperature O.K. but Moisture is too high
- Reduce Air Flow, Increase Bed Depth
Temperature is high and Moisture is high
- Increase Bed Depth, Increase Air Flow
Temperature O.K. but Moisture is too low
- Reduce Bed Depth, Increase Air Flow
Temperature is low but Moisture is high
- Increase Bed Depth, Reduce Air Flow
Temperature is low and Moisture is low
- Reduce Air Flow
Source: CPM
![Page 21: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/21.jpg)
Pellet Cooling
QUESTIONS
?????
![Page 22: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/22.jpg)
Pellet Crumbling
• Crumbling of pellets done by
cutting/shearing of whole pellets into
smaller pieces.
• A specially designed roller mill is used to
accomplish this function.
![Page 23: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/23.jpg)
Pellet Crumbling Inlet
Slow Roll
Fast Roll
Roll
Adjustment
Differential
Gearbox
Motor and
V-belt Drive
![Page 24: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/24.jpg)
Pellet Crumbling
Crumbling Rolls
Single Pair w/Automatic Gap Adjustment
![Page 25: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/25.jpg)
Pellet Crumbling
Crumbling Rolls
w/Inlet Feeder Roll
![Page 26: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/26.jpg)
Pellet Crumbling
• The crumbling action is done by passing whole
pellets between a pair of rolls set up to operate
in a sharp to sharp cutting action.
• The cutting action is accomplished by turning
one roll faster than the other.
• This difference in speed is called the speed
differential.
• Differential is the ratio of the speed of the
faster roll divided by the speed of the slower
roll.
![Page 27: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/27.jpg)
Pellet Crumbling
• The size of the crumbles is dependent on
the space between the rolls and the
treatment of the roll surfaces.
• The space is known as the “roll gap”.
• The smaller the space, the more severe
the crumbling action, the smaller the
crumble pieces.
![Page 28: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/28.jpg)
Pellet Crumbling
• The treatment of the roll surface is called
the roll “corrugation”.
• Corrugations are grooves cut into the roll
surface to help in the cutting and sizing of
the pellets into crumbles.
• In crumbling rolls the grooves run
parallel to the roll length and may have
some small degree of spiral or wrapping
around the roll.
![Page 29: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/29.jpg)
Pellet Crumbling
Roll
Dia.
Speed
Differential
Slow Roll
Speed
(rpm)
Fast Roll
Speed
(rpm)
8” 1.3:1* 453 584
10” 1.5:1 533 799
Standard Roll Speeds
* Other differentials available: 1.4 : 1, 1.5 : 1
California Pellet Mill Co.
![Page 30: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/30.jpg)
Pellet Crumbling
Roll
Dia.
Corrugation
Type
Slow Roll
Spacing
Fast Roll
Spacing
8” LePage 10/inch 10/inch
10” Round
Bottom “V”
8/inch 6/inch
Standard Roll Corrugations
California Pellet Mill Co.
![Page 31: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/31.jpg)
Pellet Crumbling
After Horizontal or Old Style Vertical Cooler:
• Roll length matches width of cooler.
• Flow rate to rolls from cooler discharge is constant and uniform and same width as crumbling rolls inlet.
• Feeder roll above crumbling rolls not required.
![Page 32: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/32.jpg)
Pellet Crumbling
After Counter Flow Cooler:
• Roll length does not match the width of cooler.
• Flow rate to rolls from cooler discharge is in surges and is not of uniform width.
• Feeder roll required above crumbling rolls to spread pellets uniformly across length of crumbling roll inlet.
![Page 33: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/33.jpg)
Pellet Crumbling
Roll Gap (looking down from above)
Correct
(Uniform Spacing) Incorrect
(Varied Spacing)
Rolls Must Be Parallel
![Page 34: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/34.jpg)
Pellet Crumbling
Roll Tram (looking from front of machine)
Correct
(Rolls Aligned) Incorrect
(Rolls Not Aligned)
Rolls Must Be In Alignment (Tram)
![Page 35: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/35.jpg)
Pellet Crumbling
All crumbling rolls must be equipped with a method to bypass the rolls:
• Old style crumbling rolls had a built-in diverter valve at inlet.
• Newer crumbling rolls are equipped to spread roll gap full open to allow whole pellets to pass through while crumbling rolls are not running.
![Page 36: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/36.jpg)
Pellet Crumbling
Summary:
• Roll surfaces must be corrugated for the size of pellets and size of crumbles to be made.
• Proper speed differential must be chosen for best control of crumble size range.
• Crumbling rolls must be fed uniformly across the entire inlet length.
• Gap setting must be uniform and rolls in tram.
![Page 37: Pellet Cooling and Crumbling · · 2015-06-12Vertical Cooler – Cross Flow ... System Design • Cooler air systems should be designed using the correct amount of air (cfm/tph)](https://reader034.vdocument.in/reader034/viewer/2022051801/5addc5617f8b9ae1408d6b68/html5/thumbnails/37.jpg)
Pellet Crumbling
QUESTIONS ???