PENDING POINTS & CONSTRAINTS FOR VWTA020 UPDATED.xls

TRANSCRIPT

VWTA020VWTA-20 PENDING POINTSSI.NODESCRIPTIONCONSTRAINTSREMARKSVESPLBAPLUTTKAL ENGINEERS1BUNKERIBUNKER CHUTE&CASING CORNER PLATE FIT UP & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEIIBALANCE WELDING IN CHUTE & CASINGSMAN POWER SHORTAGEIITEMPORARY SUPPORTS REMOVE WORKMAN POWER SHORTAGEIVMAN HOLE DOOR FIT UPVMORRIE'S WHEEL CHAIN TO BE PROVIDED2FUEL FEEDING SYSTEMIIIDIVIIDING CHUTE BALANCE SUPPORT WORKMAN POWER SHORTAGEIVPA LINE TO MIXING NOZZLE GASKET FIXINGMAN POWER SHORTAGEMATERIAL AVAILABLEVIDRAG CHAIN FEEDER SUPPORT WELDINGMAN POWER SHORTAGEVIIPA LINE SUPPORT WELDINGMAN POWER SHORTAGEVIIICROSS COVER FLANGE WITH GASKET FIXINGCOVER FLANGE REQUIREDIXFUEL LINE DRAIN TO SLIDE GATE WELDINGMAN POWER SHORTAGE3FURNACEISPORGER HEADER FLANGE JOINT WELDINGMAN POWER SHORTAGEIISPORGER HEADER SUPPORT WELDINGMAN POWER SHORTAGEIIIBOTTOM SUPPORT TIE BEAM BALANCE WELDINGMAN POWER SHORTAGEIVSPORGER HEADER DRAINMAN POWER SHORTAGEMATERIAL AVAILABLEVBALANCE FURNACE HOPPER WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEVIHOPPER MANHOLE DOOR & ATTENDING PLATFORM FIT UPDRG. REQUIREDMAN POWER SHORTAGEMATERIAL AVAILABLEVIIFUEL LINE TO FURNACE HOPPER PAD FIT UP & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEVIIIFURNACE HOPPER DRAIN PIPING AND KNIFE & SLIDE GATE FIT UPSTUD BOLTREQUIRED.4WATER WALLIIWATER WALL BOTTOM SUPPORT SEATING WORKMAN POWER SHORTAGEREWORKIIIFURNACE BED COIL SEAL BOXMAN POWER SHORTAGEMATERIAL AVAILABLE.REFRACTORY IS AN U/P.VWATER WALL ROOF SEAL BOX BALANCE WORK & WELDINGMAN POWER SHORTAGEREFRACTORY COMPLETION5BED MATERIAL BUNKER2BED MATEIAL BUNKER STIFFNER BEAM WELDINGMAN POWER SHORTAGE6AIRHEATER1AIR HEATER TUBE SHEET BALANCE WELDINGMAN POWER SHORTAGE7PLATFORM ASSEMBLYITOE PLATE FIXING WORK TO BE COMPLETED.MATERIAL AVAILABLE8ROOF TRUSS & SIDE CLADDINGISIDE CLADDING BALNCE WORKMATERIAL REQMAN POWER SHORTAGEMATRIAL SHORTAGEIIROOF TRUSS ERECTION WORKMATERIAL REQMAN POWER SHORTAGEMATERIAL SHORTAGEIIIBALNCE WELDING WORK9ZERO EXPANSION MOVEMENT DIAGRAMIWATER WALL, STEAM DRUM ZERO EXPANSION ARRESTER ERECTION WORKMAN POWER SHORTAGEINSULATION WORK COMPLETED IN THIS PLACESIIEXPANSION INDICATOR FIT UP10RISER SUPPORTIRISER SUPPORT MODIFICATION WORKMAN POWER SHORTAGEREWORK11ECONOMISERIECONOMISER CASING SCALLOPED PLATE TUBE WELDINGMAN POWER SHORTAGEIIECONOMISER INLET & OUTLET HEADER U CLAMP CHANGINGREWORK12MAIN STEAM OUTLET LINKISAFTY VALVE FIT UP & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEIITHERMOWELL CHANGINGREWORKIISPRING HANGER SUPPORT PLATE FIXINGREWORK13AIR DUCTINGIALL DUCTING FLANGES OUTER SIDE STRETCH WELDINGMAN POWER SHORTAGE14PRIMARY AIR SYSTEM ASSEMBLYIALL DUCTING FLANGES OUTER SIDE STRETCH WELDINGMAN POWER SHORTAGE15FLUE GAS DUCTING ASSEMBLYIAIR HEATER TO ESP DUCTING SUPPORT ERECTIONFOUNDATION REQIIID FAN TO CHIMNEY DUCTING ERECTION WORKCHIMNEY REQUIRED16FEED PIPINGIBALNCE PIPING FIT UP, ERECTION &WELDINGPIPE RACK REQMAN POWER REQMATERIAL AVAILABLEIIFEED PIPING SUPPORTPIPE RACK REQMAN POWER REQMATERIAL AVAILABLE17HP DOSING PIPINGIHP DOSING PIPING FIT UP & WELDING BALANCE WORKMAN POWER REQ18REMOTE PRESSURE GAUGE EXTENSION PIPINGIVALVE & CONDENSING LOOP ASSEMBLY FIT UP & WELDING WORKREDUSER REQMAN POWER19START UP OIL FIRING SYSTEMIBALANCE PIPING FIT UP, ERECTION &WELDINGMAN POWER REQMATERIAL AVAILABLEIIPIPING SUPPORTMAN POWER REQMATERIAL AVAILABLE20COOLING WATER PIPINGIFEED PUMP COOLING WATER INLET & OUTLET PIPING FIT UP & WELDINGINSERT PLATE REQMATERIAL AVAILABLEIIFEED PUMP COOLING WATER INLET & OUTLET PIPING SUPPORTINSERT PLATE REQMATERIAL AVAILABLEIIISAMPLE COOLER COOLING WATER INLET PIPING & SUPPORTMATERIAL AVAILABLE21BOILER SAFTY VALVE EXHAUST PIPINGIMAIN STEAM LINE DRIP PAN FIT UP & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEIIBALNCE SUPPORT ERECTION & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLE22NON IBR DRAIN PIPINGIALL DRAIN PIPING FIT UP & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLEIIALL DRAIN PIPING SUPPORTWORK & WELDINGMAN POWER SHORTAGEMATERIAL AVAILABLE23DEAERATORIDEAERATOR TO FEED PUMP SUCTION PIPING &SUPPORTINSERT PLATE & PIPE RACK REQMAN POWER SHORTAGEmaterial availableIIINITIAL HEATING & STEAM INLET PIPING SUPPORTINSERT PLATE REQIIIMAKE UP WATER INLET PIPING & SUPPORTINSERT PLATE REQIVDEAERATOR STROAGE TANK OVERFLOW & DRAIN PIPINGINSERTPLATE REQmaterial availableVDEAERATOR IMPULSE PIPINGMAN POWER SHORTAGEmaterial availableVIIBALANCE PLATFORM WORKVIIILP DOSING ERECTIONINSERT PLATE REQmaterial availableIXLP DOSING PIPINGINSERT PLATE REQmaterial availableXAUTO MINIMUM REIRCULATION BALNCE LEAK PIPING SUPPORT WORK.INSERT PLATE REQ24IMPULSE PIPINGISTEAM DRUM LEVEL TRANSMITTER IMPULSE PIPING WORK1"TO 1/2" CONNECTORREQ {QTY-2 NOS)IIIMPULSE PIPING BALANCE SUPPORTMATERIAL AVAILABLE25ROTARY EQUIPEMENT.IFD FAN FINAL ALIGNMANTFULL GROUTING,PACKING PLATE REQMILWRIGHT FITTERUTKAL EXTRA WORK ASKING FOR PACKING PLATE CUTTINGIIPA FAN FINAL ALIGNMENTFULL GROUTING,PACKING PLATE REQMILWRIGHT FITTERIIIFEED PUMP FINAL ALIGNMENTFULL GROUTING,PACKING PLATE REQMILWRIGHT FITTERIVID FAN ALIGNMNET & FINAL ALIGNMENTTFULL GROUTING,PACKING PLATE REQMILWRIGHT FITTER26ESPIIHOPPER BALANCE WELDINGMAN POWER REQIIIHOPPER PARTITION PLATE BALANCE FIT UPMATERIAL AVAILABLEIVHOPPER PARTITION HAMMER PLATE FIXINGVHOPPER PARTITION MAN HOLE DOOR FIT UP WORKMATERIAL AVAILABLEVIHOPPER SLIDE GATE & RAV FIXINGRAV REQMATERIAL AVAILABLEVIILONGITIDUNAL WALL SIDE COVERING PLAT FIT UP & WELDING WORKMAN POWER REQMATERIAL AVAILABLEVIIIOUTLET INTERNAL WALKWAY WORKMATERIAL AVAILABLEIXCOLLECTING ELECTRODE ALIGNMENTMAN POWER REQALIGNMENT IS VERY POOR.REALIGNMENT MUST REQUIREDXCOLLECTING ELECTRODE RAPPING SYSTEMMAN POWER REQMATERIAL AVAILABLEXIDISCHARGE ELECTRODE ALIGNMENTMAN POWER REQALIGNMENT IS VERY POOR.REALIGNMENT MUST REQUIREDXIIDISCHARGE RAPPING SYSTEMMAN POWER REQMATERIAL AVAILABLEXIIIGD PLATE LOCKING REMOVING WORKMAN POWER REQXIVGD RAPPING SYSTEMMAN POWER REQMATERIAL AVAILABLEXVBALANCE PLATFORM WORKMAN POWER REQMATERIAL AVAILABLEXVIINSULATOR ERECTION WORKMAN POWER REQMATERIAL AVAILABLEXVIIGAS DIVERTION PLATE FIT UP & WELDINGMAN POWER REQMATERIAL AVAILABLEXVIIIBLOWER WITH HEATER ERECTION & PIPING WORKMAN POWER REQMATERIAL AVAILABLEXIXHT DUCT ERECTION & HT CONNECTIONMAN POWER REQMATERIAL AVAILABLEXXSEALING ROOF ERECTION & WELDINGMAN POWER REQMATERIAL AVAILABLEXXIRAIN ROOF ERECTION & WELDINGMAN POWER REQMATERIAL AVAILABLEXXIIROOF BEAM MAN HOLE DOOR FIT UP & WELDINGMAN POWER REQMATERIAL AVAILABLE27TEMPORARY SUPPORTS REMOVINGIBOILER TEMPORARY SUPPORTSMAN POWER REQIIESP TEMPORARY SUPPORTSMAN POWER REQ28REFRACTORYIHOPPER REFRACTORY WORKCONTRACTORMISSED MATERIAL REQIIFURNACE REFRACTORY WORKCONTRACTORMISSED MATERIAL REQIIISEAL BOX REFRACTORY WORKCONTRACTORMISSED MATERIAL REQIVROOF SEAL BOX REFRACTORY WORKCONTRACTORMISSED MATERIAL REQ29INSULATIONIESP INSULATION WORKCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.IIESP TO CHIMNEY FLUE GAS DUCTING INSULATION WORKCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.IIIPIPING INSULATION WORKCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.IVDEAERATOR INSULATION & DEAERATOR PIPINGCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.VBOILER BALANCE INSULATION WORKCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.VIFAN INSULATION WORKCONTRACTOR & BALANCE MATERIAL REQMAXIMUM INSULATION MATERIALS ARE DAMAGED BY RAIN WATER.30ROOF SHEETINGMAN POWER REQSHOULD BE COMPLETE THE ROOF &SIDE CLADDING STRUCTURE31FINAL PAINTINGMAN POWER REQMATERIAL AVAILABLE

MAN POWER & TOOLS REQMAN POWER REQUIREMENT FOR BOILERTOOLS REQUIREMENT FROM UTKAL ENGGS.NODESCRIPTIONNOSS.NODESCRIPTIONNOSAVAILABLE1FITTER(PIPING)1NOS1WELDING M/C3+1 RECTIFIER4NOS2FITTER (STRUCTURE)2 NOS2GRINDING M/C AG402 NOS1NOIS3GRINDER2 NOS3SPRIT LEVEL04 NOSI NOS4RIGER03 NOS4RIGHT ANGLE05 NOSNIL5WELDER02 NOS5WATER LEVEL03 NOS01 NOS6HELPER02 NOS6LIGHT04NOS7IBR WELDER01 NOSTOTAL13 NOSMAN POWER REQUIREMENT FOR ESPIBR FORMALTIES ISSUE(UTKAL ENGG SCOPE)S.NODESCRIPTIONNOS1.VWHO BALANCE RADIOGRAPHY FILM & REPORT1FITTER2 NOS2.VWHO 052,VWHO 053 BALANCE RADIOGRAHY ARRANGEMENT & SR ARRANGEMENT2WELDER04NOS3RIGER02 NOS4HELPER04 NOSTOTAL12NOSAVAILABLE MAN POWER DETAIL IN BOILERS.NODESCRIPTIONNOS1SUPERVISIOR1NOS1FITTER2 NOS2WELDER04NOS3RIGER02 NOS4HELPER05 NOSTOTAL14 NOS*MAN POWER NOT AVAILABLE IN ESPNOTE: UTKAL ENGG SOME TIME PUT HIS MAN POWER TO CUSTOMER WORK FROM THIS MAN POEWER.SO THIS MAN POWER IS NOT STATICMAN POWER & TOOLS REQUIREMENT FOR REFRACTORY1TOTAL10 NOS WITH NECESSORY TOOLSMAN POWER & TOOLS REQUIREMNET FOR INSULATION1TOTAL15 NOS WITH NECESSORY TOOLSMAN POWER REQUIREMENT FOR SHEETING1TOTAL15 NOS WITH NECESSORY TOOLS