Perfection that Matters
Switchgear Range Catalogue 2017
![Page 2: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/2.jpg)
When aesthetics come together with state-of-the-art technology, you get a product as refined as
Crabtree. Crabtree modular switches have been adorning walls in homes and offices for years. Our
endeavour is to always create products that adhere to the highest engineering standards.
Crabtree is introducing a new category of switchgear - XPRO, a smart and efficient range of
products that are designed to stand the test of time.
This user friendly range offers enhance safety and is designed to meet regular as well as customer
specific requirements
High professionalism & product quality have made Crabtree a distinguished company. Production
here is a symbiosis between advanced technology, maximum functionality and aesthetic designing
to match the taste of the discerning clientele.
Today, Crabtree is committed to meeting the challenges of the new economy through business
ethics, global reach and technological expertise.
Contents
Power Series Distribution Boards
Classique Distribution Boards
Miniature Circuit Breaker
Isolator
Residual Current Circuit Breaker
Residual Current Circuit Breaker With Overload and Short Circuit Protection
Automatic Changeover
Time Switch
Distribution Boards at Glance
Product Ordering Information
04
14
30
44
48
58
62
68
78
80
Perfection that Matters
![Page 3: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/3.jpg)
4 5
Perfection that Matters
General Characteristics
Crabtree introduces the new XPRO Power series of Distribution Boards with increased safety, meeting the International standards. The range offers a variety of feature benefits, such as Conditional short circuit rating of 15kA in SPN DB and 25kA in TPN DB in accordance with IS 13032, BS EN 60439-3, Shrouding on all phase/ neutral terminals along with physically isolable neutral link, High integrity/Clean earth kit for electronic/ IT installations, Ample space for wiring and proper distribution of neutral & earth wire.
POWER SERIES DISTRIBUTION BOARDS
Quality Features
Modern styling allows the range to discreetly blend in with both industrial and commercial premises
Shrouded terminals for Phase/ Neutral ensure complete safety against any accidental touch of live parts by servicing personnel
Multi-fold design technology in fabrication from single sheet steel lends ruggedness and structural strength
Generous wiring space. 25mm2 of terminal capacity for earth & neutral bars and dual earth and neutral bars provided on TPN
Distribution Boards for ease of installation, makes it a user friendly design
Provision of Clean Earth (High Integrity Earthing) kit for electronic ( IT ) installations in TPN Distribution Board
Removable Main busbar/ Pan Assembly in SPN/TPN Distribution Board to aid installation.
Main earth stud allows earth to be terminated inside or outside the enclosure
The door when locked (with barrel lock) covers all devices and front cover screws to prevent unwanted access
Physically isolable neutral link is provided to carry out insulation test in TPN Distribution Boards
![Page 4: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/4.jpg)
76
Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS
TPN Vertical Load Line
DIMENSIONS (in mm)
TPN Vertical Load Line
405
395335
A B C
125
127
3
Technical Specification
No. of Ways 4, 6, 8 & 12 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Snap Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Fish-bone Busbar
Busbar Rating 160 A
Busbar Short Time Withstand (Icw) 10 kA for 0.5 second
Busbar Conditional Short Circuit (Ics) 25 kA
Incoming Max. 160 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options G Frame MCCB 160 A (3P or 3P+N)
Residual Current Protective Devices Options MCB / RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2, Split on both sides
Earthing Bar Terminal Capacity 25 mm2, Split on both sides
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529t
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM SIDE
(EACH SIDE)Ø31 Ø31 Ø50
4 570 560 494
6 4 1 26 624 614 548
8 678 668 602
12 778 776 710
![Page 5: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/5.jpg)
98
Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS
Flexy Double Door Distribution Board
DIMENSIONS (in mm)
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM SIDE
(EACH SIDE)Ø31 Ø31
2 X 13 295 400 428
6 6 23 X 13 453 558 586
4 X 13 591 666 694
Flexy Double Door Distribution Board
307395
3801911
428
BC A
Technical Specification
No. of Ways 2 X 13W, 3 X 13W & 4 X 14W
Type of Installation Flush / Surface
Door Options Rectangular
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 VAC, 3 Phase / 4 Wire
Incoming Options As per site requirement i.e., 100 A Isolator (4P); 100 A RCCB
Earth Leakage Protective Devices RCCB / RCBO
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 VAC
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 13032 ; IEC 60439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS/IEC 61009 ; IS/IEC 61008
Index of Protection (IP) - Reference Standard IS/IEC 60529t
![Page 6: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/6.jpg)
10 11
Perfection that Matters Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS
SP&N DISTRIBUTION BOARD
Fully shrouded neutralbusbar for increased safety
Combination screw headson all devices
Easy access earth bar canaccommodate up to
25mm2 cables
Stand-off foot form forstable installation
High quality clear subcircuit identification labels
Removable gland platestop/bottom for ease ofinstallation
New 100A SwitchDisconnector incomer options
180°opening for easy access
Cover screwed by meansof combination screws
SP&N DISTRIBUTION BOARD
DIMENSIONS (in mm)
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM
Ø31 Ø31
4 237 162 3 3
6 273 198 4 4
8 345 270 4 4
12 399 324 6 6
16 453 378 7 7
11.5
92
654.5
3615
9.5
248
B
A
Technical Specification
No. of Ways 4, 6, 8, 12 & 16 Ways
Type of Installation Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 15 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240 Vac, 1 Phase
Incoming Options Up to 100 A Isolator (2P) or 100 A RCCB (2P)
Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2
Earthing Bar Terminal Capacity 25 mm2
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529t
![Page 7: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/7.jpg)
12 13
Perfection that Matters Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS
PER PHASE ISOLATION (PPI) VERTICAL - 4 TIER
Clean Earth Bar Provision
Stand-off foot form for stable installation
Earthing Screw
Neutral link per phase
RCCB 2P
Main Neutral
Outgoing MCB 1P
Main Incomer Isolator 4P
Earth Bar
11.5
87
4.5
7674
0
640
A
B
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM
ø 31 ø 31
2+4 311 186 4 4
2+6 340 222 6 6
2+8 378 258 6 6
2+12 448 330 8 8
PER PHASE ISOLATION (PPI) VERTICAL - 4 TIER
Technical Specification
No. of Ways 2+4, 2+6, 2+8 & 2+12 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Straight Busbar
Busbar Rating 125 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P) or 100 A RCCB (4P)
Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2
Earthing Bar Terminal Capacity 25 mm2
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 8: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/8.jpg)
14 15
Perfection that Matters Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS
TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD
Increased width of board to 440 mmto maximize wiring space
Incomer 125A 4P/ 3P
Stepped Earth & Neutral bar assembly, to ease installation and improve access for testing
Terminal Shield covers for increased safety
Shrouding over Incomer
Combination screw headson all devices
Removable gland plates areprovided top/ bottom for
ease of installation
MCB 10 kA
Provision for mounting Clean Earth Kit
High quality - a clear sub circuit identification labels
Secondary cover slides over two location screws at bottom of board for easier fastening
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM SIDE
ø 31 ø 31 ø 38
4 430 248 8 6 1
6 484 329 8 6 1
8 538 410 8 6 1
12 700 572 8 6 1
440
11.5
126.
5
100
74B A
320
TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD
Technical Specification
No. of Ways 4, 8 & 12 Ways
Type of Installation Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Fish-bone Busbar
Busbar Rating 125 A
Busbar Short Time Withstand (Icw) 10 kA for 0.5 second
Busbar Conditional Short Circuit (Ics) 25 kA
Incoming Max. 125 A
Outgoing Max. Individual 63 A (SP & TP)
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options Up to 125 A Isolator (4P, 3P & 2P) or 100 A RCCB
Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2, Split on both sides
Earthing Bar Terminal Capacity 25 mm2, Split on both sides
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 9: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/9.jpg)
16 17
Perfection that Matters Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS
TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD SUITABLE FOR 80-125A MCB INCOMER
11.5
122.
3
954.
5
BA
440
320
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM SIDE
ø 38 ø 31 -
4 266 426 3 2 -
6 338 480 3 2 -
8 410 534 3 2 -
12 581 696 3 2 -
Technical Specification
No. of Ways 4, 8 & 12 Ways
Type of Installation Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Fish-bone Busbar
Busbar Rating 125 A
Busbar Short Time Withstand (Icw) 10 kA for 0.5 second
Busbar Conditional Short Circuit (Ics) 25 kA
Incoming Max. 125 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options MCB 125 A (3P or 3P+N)
Residual Current Protective Devices Options RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2, Split on both sides
Earthing Bar Terminal Capacity 25 mm2, Split on both sides
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
FP VERTICAL DOUBLE DOOR DISTRIBUTION BOARD SUITABLE FOR 160A MCCB INCOMER
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM SIDE
ø 31 ø 38 -
4 536 416 2 3 -
8 644 524 2 3 -
12 752 632 2 3 -
440
11.5
AB4.
5 91 118
340
Technical Specification
No. of Ways 4, 8 & 12 Ways
Type of Installation Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Fish-bone Busbar
Busbar Rating 160 A
Busbar Short Time Withstand (Icw) 10 kA for 0.5 second
Busbar Conditional Short Circuit (Ics) 25 kA
Incoming Max. 160 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options G Frame MCCB 160 A (3P or 3P+N)
Residual Current Protective Devices Options RCBO as Outgoing
Neutral Bar Terminal Capacity 25 mm2, Split on both sides
Earthing Bar Terminal Capacity 25 mm2, Split on both sides
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 10: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/10.jpg)
18 19
Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS
Quality Features
Aesthetically superior Distribution Boards to suit the style of your interior décor.
3 Piece Concept for ease of maintenance - where instead of removing door assembly (Inner & Outer) only the intermediate plate needs to be removed for the purpose of maintenance, without spoiling the alignment & associated plastering / paint work.
Suitable for surface as well as flush mounting.
Ample knockouts in the top, bottom and sides for ease of wiring.
General Characteristics
Crabtree introduces the new XPRO series of aesthetically superior Distribution Boards with suitable Busbars for different ratings. Performance tested with a Conditional Short Circuit rating of 10 kA in SPN DB and TPN DB in accordance with IS 13032, BS EN 61439-3
![Page 11: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/11.jpg)
20 21
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
Classique - II Distribution Board - SPN Classique - II Distribution Board - SPN
Technical Specification
No. of Ways 4, 6, 8, 12 & 16 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240 Vac, 1 Phase
Incoming Options 100 A Isolator (2P) or 100 A RCCB (2P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (2P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 43
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM
SIDEø 25 ø 31 ø 25 ø 31
4 175 121 208 2 - 2 - 1
6 211 157 244 3 - 3 - 1
8 247 193 280 2 2 2 2 1
12 319 265 352 4 2 4 2 1
16 391 337 424 4 2 4 2 1
DIMENSIONS (in mm)
255
A
B 3
105
98
162
C
222
![Page 12: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/12.jpg)
22 23
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
Classique - II Distribution Board - TPN Classique - II Distribution Board - TPN
Technical Specification
No. of Ways 4, 6, 8 & 12 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P) ; 100A RCCB (4P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 43
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM SIDE
(EACH SIDE)ø 31 ø 31
4 323 235 356 4 4 2
6 323 235 356 6 6 2
8 395 307 428 6 6 2
DIMENSIONS (in mm)
428
295
B
A
310
9
116
C
400
![Page 13: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/13.jpg)
24 25
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
SP&N DISTRIBUTION BOARD SP&N DISTRIBUTION BOARD
Technical Specification
No. of Ways 4, 6, 8, 12 & 16 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240 Vac, 1 Phase
Incoming Options 100 A Isolator (2P) or 100 A RCCB (2P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (2P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 43
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
323323395534
235235307461
356356428566
428
295
B
A
310
9
116
C
400
![Page 14: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/14.jpg)
26 27
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
TP&N DISTRIBUTION BOARD
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM SIDE
ø 31 ø 31 ø 31
4 323 235 356 4 4 2
6 323 235 356 6 6 2
8 395 307 428 6 6 2
12 534 461 566 8 8 2
TP&N DISTRIBUTION BOARD
Technical Specification
No. of Ways 4, 6, 8 & 12 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P) ; 100A RCCB (4P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 43
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
2785 11
23B
A
C
428
295
DIMENSIONS (in mm)
![Page 15: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/15.jpg)
28 29
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
TP&N PPI DISTRIBUTION BOARD
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM SIDE
ø 31 ø 31 ø 31
4 323 268 356 4 4 2
6 395 329 428 6 6 2
8 534 479 567 8 8 2
TP&N PPI DISTRIBUTION BOARD
Technical Specification
No. of Ways 4, 6, & 8 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 100 A
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P)
Residual Current Protective Devices Options DP RCCB as Sub Incomer
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 43
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
2785
3BA
C
428
345
DIMENSIONS (in mm)
![Page 16: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/16.jpg)
30 31
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
8 SEGMENT DD DISTRIBUTION BOARD
Neutral Bar
Earth Bar
Sub Incomer RCCB (2P)
RCCB (4P)
Main Incomer Isolator (4P)
Outgoing MCB (1P)
Space for Changeover/Isolator
Outgoing MCB (1P)
102
91
625
659
485
A
C
B 3
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A B C TOPø 31
BOTTOMø 31
SIDEø 31
4 440 380 474 7 7 -
6 548 488 582 8 8 -
8 656 596 690 10 10 -
12 872 812 906 13 13 -
8 SEGMENT DD DISTRIBUTION BOARD
Technical Specification
No. of Ways 4, 6, 8 & 12 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 63 A per phase
Outgoing Max. Individual 63 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P) & 100 A RCCB (4P) or RCBO (4P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 60439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 17: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/17.jpg)
32 33
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
CLASSIQUE PLUS AUTOMATIC PHASE SELECTOR DISTRIBUTION BOARD
AUTOMATIC PHASE SELECTOR (APS)
Automatic Phase Selector
Outgoing MCB 1P
Technical Specification
Reference Standard IEC 60947-6-1
No. of Poles 3P+N
Rated Current (In) 32 A
Rated Voltage (Ue) 415 Vac
Load Carrying Capacity / Per Phase 63A
Operating Voltage Range 200 to 415 Vac
Rated Frequency 50 Hz
Time Delay for Phase Changeover 3 second
Utilization Category AC31A
Indication Individual phase (R, Y, B), load, fault, type of fault (i.e. Undervoltage or Overvoltage)
Ambient Temperature -5° C to +55° C
Electrical Life 6000 operations
Rated Impulse Voltage (Uimp) 2.5 kV
Conditional Short Circuit Breaking Capacity 3 kA
Mounting DIN rail mounting
Terminal Capacity 10 mm2
Phase Priority Selection Manual (RYB, YBR, BRY)
Undervoltage Protection (L-N) 170 V (Factory Sealed)
Overvoltage Protection (L-N) 300 V (Factory Sealed)
Dimensions (L x W x H) in mm 87.5 x 71.8 x 63 mm
360
465
493
C
A
B
1010
3
100
3
No. of Ways
Rating
DIMENSIONS KNOCKOUT HOLES
A B CTOP BOTTOM
Ø31 Ø31
4 32A 473 394 505 6 6
6 32A 528 453 560 8 8
CLASSIQUE PLUS AUTOMATIC PHASE SELECTOR DISTRIBUTION BOARD
Technical Specification
No. of Ways 4 & 6 Ways
Type of Installation Flush / Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Advanced
Distribution Technique Straight Busbar
Busbar Rating 125 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 63 A
Outgoing Max. Individual 32 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 63 A Isolator or 63 A RCCB & 63 A MCB
Residual Current Protective Devices Options RCCB or RCBO as Incomer
Neutral Bar Terminal Capacity 25 mm2
Earthing Bar Terminal Capacity 25 mm2
Index of Protection (IP) IP 2X / IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 18: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/18.jpg)
34 35
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
CLASSIQUE PLUS MANUAL PHASE SELECTOR HORIZONTAL DISTRIBUTION BOARD
11.5
135
435
360
108
4.5
A
B
No. of Ways
DIMENSIONS KNOCKOUT HOLES
A BTOP BOTTOM SIDE
ø 20 ø 25 ø 20 ø 25 ø 31
4 470 338 7 8 7 8 3
6 542 410 8 9 8 9 3
8 614 482 10 11 10 11 3
CLASSIQUE PLUS MANUAL PHASE SELECTOR HORIZONTAL DISTRIBUTION BOARD
Technical Specification
No. of Ways 4,6 & 8 Ways
Type of Installation Surface
Colour / Finish Bucket White Texture Finish
Door Options Flat Version
Door Locking Options Barrel Key Lock
Removable Gland Plates Top & Bottom
Protection Level of Distribution Boards Standard
Distribution Technique Straight Busbar
Busbar Rating 100 A
Busbar Short Time Withstand (Icw) 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics) 10 kA
Incoming Max. 63 A per phase
Outgoing Max. Individual 32 A
Voltage Rating 240-415 Vac, 3 Phase / 4 Wire
Incoming Options 100 A Isolator (4P) & R, Y, B Indicating Lights (3P+N) & 100 A RCCB (4P)
Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)
Neutral Bar Terminal Capacity 16 mm2
Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 42
Insulation Voltage (Ui) 690 Vac
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard IS/IEC 60529
DIMENSIONS (in mm)
![Page 19: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/19.jpg)
36 37
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
TIMER DISTRIBUTION BOARDKeeping the space constraint at the ATM sites, Havells has launched power solutions that will improve uptime and reduce operational costs of ATMs (Automated Teller Machine). It has a built-in energy saving timer based control for the ATM air conditioner and lights of the lobby and backroom. it is also suitable for controlling ACs, Pumps, Street Lights & Motors etc.
TIMER DISTRIBUTION BOARD
Technical Specification
Type of Installation Flush / Surface
Colour / Finish Bucket White
Door Options Flat Version
Incoming DP RCBO/RCCB/MCB
Outgoing MCB
Voltage Rating 240 Vac
Neutral & Earthing Bar Terminal Capacity 16 mm2
Index of Protection (IP) IP 42
Frequency 50 Hz
Ambient Temperature -5° C to 40° C
Distribution Board - Reference Standard IEC 61439 - 3
Index of Protection (IP) - Reference Standard IS/IEC 60529
Contactor TP 25A, 240 Vac
Timer 24 Hour Programmable Time Switch
WIRING DIAGRAMTimer Classique DB Power Wiring
WIRING DIAGRAM Timer Classique DB Control Wiring
115
312
344
465
493 36
013
2.2
DIMENSIONS (in mm)
![Page 20: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/20.jpg)
38 39
Perfection that Matters Perfection that Matters
CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
PLUG & SOCKET
RatingDimensions (in mm)
Knockout Holes (Ø25)
A B C D E Top Bottom
20A SP 152 116 167 139 124 2 2
20A DP 152 116 167 139 124 2 2
30A TP 278 230 293 129 114 1 1
MCB ENCLOSURE - SHEET STEEL
102
63
10C A
E
BD
No. of Ways
Dimensions (in mm)Knockout Holes
(Ø25)
A B C D E Top Bottom
DP 60 160 70 170 30 1 1
FP 98 180 108 190 62 2 2
MCB ENCLOSURE - PLASTIC
of the Electrical appliances.
142
110
A61B
No. of WaysDimensions (in mm)
A B
SP / DP 29.4 43.4
TP / FP 57 79
![Page 21: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/21.jpg)
40 41
Perfection that Matters
General Characteristics
Crabtree introduces the new XPRO range of MCBs rating from 0.5 A to 125 A. The range offers a variety of feature benefits such as Uniform Breaking Capacity of 10kA across entire range in accordance with IS/IEC 60898-1 & IS/IEC 60947-2, it also incorporates features like Inscription Window, Safety Terminal, Large Cable terminals, Bi stable Clip, Positive Contact Indication, Field fittable Auxiliary Contacts & Air Circulation (When two poles are placed adjacent to each other the channels between two poles form a tunnel resulting in very effective air circulation around individual poles)
MINIATURE CIRCUIT BREAKER
Quality Features
Inscription Window - Ensures circuit identification and hence reduces maintenance downtime
Safety Terminals - They guide the cable towards the cage terminal and avoid improper cable termination
Large Cable Terminals - The terminals are suitable for cables up to 35mm2 cross section area thus
making it suitable for copper and aluminium cables
Bi Stable Clip - Every device is provided with a dual position DIN rail clamp. Hence, a device can
be easily changed from a bank of devices connected by a busbar without disturbing your existing wiring
Positive Contact Indication - It clearly indicates contact position through Flag Indication (Red-ON, Green-OFF)
thus enhancing safety
Air Circulation - When two poles are placed adjacent to each other, the channels between two poles form
a tunnel resulting in very effective air circulation around individual poles
Field fittable Auxiliary Contacts
![Page 22: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/22.jpg)
Perfection that Matters Perfection that Matters
MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER
42 43
CIRCUIT BREAKER DEFINITION
A circuit breaker is an electro mechanical device designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. Unlike a fuse, which operates once and then has to be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation
CONSTRUCTIONMiniature Circuit Breakers have precisely formed moulded case & cover of flame retardant high strength thermoplastic material having high melting point, low water absorption, high dielectric strength and temperature capacity. The Switching Mechanism is independent, manual and trip free, i.e., the breaker trips internally even if the operating knob is held in ON position.
The Contact Mechanism comprises of fixed & moving contacts specially designed for reliability, long life and anti-weld properties.The Arc Extinguishing Device comprises of 13 plates arc chute. The arc under the influence of the magnetic field and arc guide is moved into the arc chute where it is rapidly split and quenched. The tripping mechanism is Thermal Magnetic Type.
THERMAL OPERATIONThe thermal operation provides protection from moderate overloads. Under overload condition, a thermometallic element (bimetallic strip) deflects until it operates a latching mechanism allowing the main contacts to open.
MAGNETIC OPERATIONIn magnetic operation, large overloads or short circuit current actuates a solenoid causing a plunger to strike the latching mechanism rapidly opening the main contacts.
INTERNAL VIEW
Dual Outgoing Terminal
Bimetal Strip
Knob
Magnetic Coil
Positive ContactIndication
Fix Contact
Moving Contact
Dual Incoming Terminal
Arc Runner
Arc Chutes
Back paper
Calibration Screw
Bimetal Carrier
Safety Terminal
Technical Specification
Reference Standard IS/IEC 60898-1 ; IS/IEC 60947-2
Type / Series C & D Curve
No. of Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P
Rated Current (In) 0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Short Circuit Breaking Capacity10 kA - C Curve 10 kA - D Curve, 32A 4.5 kA - D Curve, > 32A
Magnetic Release Setting(5-10)In - C Curve(10-20)In - D Curve
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 4000
Operating Temperature -5° C to +55° C
Humidity 95% RH
Energy Limit Class 3
Terminal Capacity (max) 35 mm2
Tightening Torque 2 N-m
Vibration 3 g
Shock Resistance 40 mm free fall
Protection Class IP20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight / Pole in kg 0.125 kg
Dimensions (H x D x W) / Pole in mm 87.5 x 62 x 17.7 mm
Mounting Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame-retardant thermoplastic material
Busbar Connections Top Side Pin Type
Busbar Connections Bottom Side Pin / Fork Type
Auxiliary Contacts Yes
Shunt Trip Yes
53.1 70.817.7
5.3
35.4 50.8
92.8
4462
71.7
4587.5
6.8
42
LEN
GTH
STR
IP
LEN
GTH
STR
IP
MINIATURE CIRCUIT BREAKER DIMENSIONS (in mm)
![Page 23: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/23.jpg)
Perfection that Matters Perfection that Matters
MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER
44 45
CHARACTERISTICS CURVES
TRIPPING CHARACTERISTICS
Based on the Tripping Characteristics, MCBs are available in ‘C’ and ‘D’ curve to suit different types of applications.
‘C’ Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits). Short circuit release is set to (5 - 10) In
‘D’ Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In
THERMAL TRIPPING
The Tripping is initiated by a bimetal strip in case of overload. The standard defines the range of tripping for specific overload values. Reference ambient temperature is 30°C.
MAGNETIC TRIPPING
An electromagnet with plunger ensures instantaneous tripping in the event of short-circuit.
Based on the Tripping Characteristics, MCBs are available in ‘C’ and ‘D’ curve to suit different types of applications.
‘C’ Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits). Short circuit release is set to (5 - 10) In
‘D’ Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In
As per
Thermal Tripping Magnetic Tripping
No tripping
Tripping Time Hold Trip Time
IS / IEC 60898-1
Current Current Limits Current Current Limits
I1 I2 t I4 I5 t
C Curve1.13 x In >1h 5xIn >0.1s
1.45 x In <1h 10 x In <0.1s
D Curve1.13 x In >1h 10xIn >0.1s
1.45 x In <1h 20 x In <0.1s
l3 = 2.55 x lN1 s < t < 60s for ln (In 32A)
1 s < t < 120s for ln (In 32A)
CHARACTERISTICS ACCORDING TO IS/IEC 60898-1
Miniature Circuit Breakers (MCB) are intended for the protection of wiring installations against both overloads and short-circuits in domestic or commercial wiring installations where operation is possible by uninstructed people
CURRENT LIMITING DESIGN
In a current limiting breaker, the tripping & arc control mechanism are so designed that under short circuit conditions, the contacts are physically separated and the electrodynamic forces set up by fault current, assist the extinction in less than half cycle.
The figure shows the current limiting effect of circuit breakers.
Fault Traces for Voltage & Current
0 = Point of fault initiation
tx = Contact opening time (i.e., creation of arc)
t1 = Current / Voltage peak (i.e., current limitation)
t2 = Time to total extinction of arc (i.e., complete shutdown of fault current)
HAMMER TRIP MECHANISM
Current Limiting design in itself may not fulfill the requirement of quick breaking (instantaneous action) mainly due to inertia of the Latch mechanism and interconnected sequence of operations.
A Hammer directly connected to the plunger strikes the moving contact arm with a force proportional to the peak current there by forcibly separating the moving contact from the fixed contact much before the latch mechanism operates. This further reduces the opening time of the circuit breaker.
Plunger
Hammer
![Page 24: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/24.jpg)
Perfection that Matters Perfection that Matters
MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER
46 47
Calculation In / switch = K1 x K2 x In
Example 4 MCBs with In = 10A, and the amb. temp. is 50°C kept with no gap in between
Solution K1 =0.89 (from graph 1)
K2 =0.78 (from graph 2)
In / pole = 0.89 x 0.78 x 10 = 6.94 A
thus from this we know that if we use more than 2 MCB together, their rating gets effected
Diversity Factor(K2 Factor)
Graph 2
K2
Maximum Permissible Rated Current(K1 Factor)
K1
Graph 1
AMBIENT TEMPERATURE COMPENSATION / DIVERSITY FACTOR CHART
EFFECT OF FREQUENCY VARIATION
MCBs are designed to operate at AC frequency 50 / 60 Hz. However, MCBs specially suitable for DC applications and for frequencies upto 400Hz can be supplied on request.
These can be used on different frequencies in supply from 16 2/3 - 60 Hz without any deration.
For higher frequencies, normal MCBs can be used with a multiplication factor which shall only affect its magnetic trip current.
Supply AC DC
Frequency 100Hz 200Hz 400Hz
MultiplicationFactor
1.1 1.2 1.5 1.5
let through energy i2t
MCB Current Rating (A) Backup Fuse Rating (A)
1 25
2 35
4 50
6 80
10-63 100
COLD RESISTANCE & POWER LOSS DETAILSTHE POWER LOSS VALUE DECLARED ARE AT RATED CURRENT.
Remarks:- Tolerance ±5%
Rated CurrentIn (A)
Cold ResistanceRI (m )
Power Loss Per Pole (Watt)
0.5 3467 1.3
1 1178 1.3
2 281 1.5
3 156 2.1
4 92 2.2
6 16.55 0.7
10 11.68 1.4
13 10.1 1.7
16 8 2.2
20 5.25 2.5
25 3.78 3.1
32 2.57 3.4
40 1.94 3.9
63 1.4 7.3
MAXIMUM BACKUP PROTECTION
At site, no. of MCBs are used for outgoing connection. To protect the MCBs under short circuit (higher capacity), we need to put fuses in the incoming side. The current rating of fuses should not be more than the values given in the table.
The power loss of circuit breakers is closely controlled by the Standards and is calculated on the basis of the voltage drop across the main terminals measured at the rated current. The power loss of Crabtree circuit breakers is much lower than that required by the IS/IEC Standard, giving the benefit of cooler running and reduced heating effects when mounted in groups.
![Page 25: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/25.jpg)
Perfection that Matters Perfection that Matters
MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER
48 49
MCB SELECTION CHARTFOR HOUSE HOLD APPLICATIONS
Appliances Capacity / watt (Load) (240V~ 1ph) Current Rating of MCB Type of MCB
Air Conditioner
1.0 tonnes 10A* “C” series
1.5 tonnes 16A* “C” series
2.0 tonnes 20A* “C” series
Refrigerator165 litres 3A* “C” series
350 litres 4A* “C” series
Oven cum Griller4500W 32A “C” series
1750W 10A “C” series
Oven onlyHot Plate onlyRoom Heater
750W 6A “C” series
2000W 10A “C” series
1000W 6A “C” series
2000W 10A “C” series
Washing Machine 300W 2A “C” series
Washing Machine (with heater) 1300W 8A “C” series
SELECTION OF MCB FOR MOTOR PROTECTION
Incomer Current Rating, For Three Phase :
S. No. kW HP
1 Phase 230V DOL Starting
3 Phase 400V DOL Starting
3 Phase 400V Assisted Starting Star Delta
Full Load Current
MCB Selection
Full Load Current
MCB Selection
Full Load Current
MCB Selection
1 0.18 0.24 2.8 10 0.9 2 — — —
2 0.25 0.34 3.2 10 1.2 2 — — —
3 0.37 0.50 3.5 10 1.2 2 — — —
4 0.55 0.74 4.8 16 1.8 3 — — —
5 0.75 1.01 6.2 20 2.0 3 — — —
6 1.1 1.47 8.7 25 2.6 6 — — —
7 1.5 2.01 11.8 32 3.5 10 — — —
8 2.2 2.95 17.5 50 4.4 10 — — —
9 3 4.02 20.0 63 6.3 16 6.3 16 10
10 3.75 5.03 24.0 80 8.2 20 8.2 20 10
11 5.5 7.37 26.0 80 11.2 25 11.2 32 16
12 7.5 10.05 47.0 125 14.4 40 14.4 40 25
13 10 13.40 — — 21.0 50 21.0 50 32
14 15 20.11 — — 27.0 100 27.0 63 40
15 18.5 24.80 — — 32.0 125 32.0 — 50
16 22 29.49 — — 38.0 125 38.0 — 63
17 30 40.21 — — 51.0 125 51.0 — 63
Total Load in Watts
Total Load in Watts
240V
3X415V
Calculation Formulae :
Incomer Current Rating, For Single Phase :Note : One lighting circuit can have upto 800W or upto 10 lighting points
One power circuit can have upto 2000W or 1 power points
* It may vary from manufacturer to manufacturer. Please check before installation.
MCB Downstream
MCB Upstream ‘C’ Curve
‘C’ Curve 10A 16A 20A 25A 32A 40A 50A 63A
0.5 to 5A 50 80 100 125 160 200 250 315
6A 80 100 125 160 200 250 315
10A 100 125 160 200 250 315
16A 160 200 250 315
20A 200 250 315
25A 250 315
32A 315
40A
50A
DISCRIMINATION DATA
MCB Downstream
HRC Fuse Link Upstream
‘C’ Curve 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A
0.5 to 6A 700 850 960 1200 1350 1750 2800 4500 5200 6000
10A 700 960 1200 1350 1750 2800 4500 5200 6000
13A 850 1200 1200 1750 2800 4500 5200 6000
16A 960 1100 1500 2500 3200 5200 6000
20A 1100 1500 2500 3200 4500 5200
25A 960 1350 2000 3200 4500 5200
32A 1200 1750 2800 4500 5200
40A 1750 2800 4500 5200
50A 2500 3200 4500
63A 3200 4500
DISCRIMINATION WITH FUSES
HRC Fuse Upstream Type gG
MCB Downstream
MCCB Upstream
‘C’ Curve 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200 250A 320A 400A 500A 630A 800A 1000A 1250A 1600A
0.5 to 6A 1100 1200 1400 1700 2000 2500 3400 4800 5800 6700 T T T T T T T T T T T
10A - 1100 1200 1400 1700 2100 2500 3000 3500 4300 T T T T T T T T T T T
16A - - - 1300 1600 1900 2100 2400 2700 3200 8300 T T T T T T T T T T
20A - - - - 1600 1900 2100 2400 2700 2500 8300 T T T T T T T T T T
25A - - - - - 1700 1800 2000 2200 2500 5400 8700 T T T T T T T T T
32A - - - - - - 1800 2000 2200 2500 5400 8700 T T T T T T T T T
40A - - - - - - - 1500 1700 2000 4300 7000 T T T T T T T T T
50A - - - - - - - - 1300 1500 3600 5900 9000 T T T T T T T T
63A - - - - - - - - - 1100 2800 5200 8200 T T T T T T T T
Prospective Fault Levels to which selectivity is achieved ( T = Total Selectivity )
![Page 26: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/26.jpg)
Perfection that Matters
MINIATURE CIRCUIT BREAKER
5150
Perfection that Matters
MINIATURE CIRCUIT BREAKER (80A-125A)
Electrical Distribution needs are continuously evolving in residential, commercial and industrial sectors. Improved operational safety, continuity of service, greater convenience and operating cost have assumed a tremendous significance. Crabtree Miniature Circuit Breakers have been designed to continuously adopt to these changing needs.
Technical Specification
Reference Standard IS/IEC 60947-2 ; IS/IEC 60898-1
Type / Series C curve
No. of Poles 1P, 2P, 3P, 4P
Rated Current (In) 80A, 100A, 125 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Ultimate Short Circuit Breaking Capacity (Icu) 10 kA
Rated Service Short Circuit Breaking Capacity (Ics) 75% of Icu
Magnetic Release Setting (5-10)In
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 4000
Operating Temperature -5° C to +55° C
Humidity 95% RH
Energy Limit Class 3
Terminal Capacity (max) 50 mm2
Tightening Torque 3.5 N-m
Vibration 3 g
Shock Resistance 40 mm free fall
Protection Class IP 20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight / Pole in kg 0.150 kg
Dimensions (H x D x W) / Pole in mm 81 x 64.3 x 26.5 mm
Mounting Clip on DIN Rail (35mm x 7.5mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material
Busbar Connections Top Side Pin Type
Busbar Connections Bottom Side Pin Type
MINIATURE CIRCUIT BREAKER (80A-125A)
MINIATURE CIRCUIT BREAKER
DIMENSIONS (in mm)
![Page 27: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/27.jpg)
Perfection that Matters
MINIATURE CIRCUIT BREAKER
5352
Perfection that Matters
Attachment used for Signalling, Indication, Annunciation and Interlocking
Technical Specification
Standard Conformity IS/IEC 60947-1
Current Carrying Capacity (Max) 6 A
Rated Voltage (Ue) 240 Vac
Contact Configuration 1 NO + 1 NC
Utilization Category AC 11
Electrical Endurance (No. of operations) 10000
Terminal Capacity (Max) 6 mm2
Protection Class IP 20 as per IS/IEC 60529
Mounting Left side of MCB (Field Fittable)
8.85 8.85
11.36.8
16.516.5
S-TYPE AUX
H-TYPE AUX
62.0
44.0
69.8
1.4
87.5
45.0
2.4
11.3
MCB AUXILIARY CONTACT DIMENSIONS (in mm)
ACCESSORIES
AUXILIARY CONTACT
MINIATURE CIRCUIT BREAKER
1. To trip the Circuit Breaker through Shunt Trip Coil, 70% to 110% of the rated voltage is to be applied across D1 & D2
2. The Shunt Trip coil is short time rated and it trips the breaker instantaneously (i.e. continuous duty not required)
Attachment used for remote tripping
Technical Specification
Standard Conformity IS/IEC 60947-3
Coil Consumption 6 VA
Rated Voltage (ac) (Ue) 240 V
(dc) (Ue) 48, 24, 12 V
Rated Frequency 50 Hz
Operating Voltage Range 70% to 110% of rated voltage
Electrical Endurance (No. of ops) 10000
Terminal Capacity (Max) 25 mm2
Protection Class IP 20 as per IEC 60529/IS-2147
Mounting Right side of MCB
(Factory assembled)
35.4 50.8
92.8
44
62
71.7
4587.5
6.8
42
LENGTH
STRIPLENGTH
STRIP
MCB SHUNT TRIP DIMENSIONS (in mm)
SHUNT TRIP
![Page 28: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/28.jpg)
Perfection that Matters
ISOLATORS
5554
Perfection that Matters
ISOLATOR
Inscription Window Safety Terminal Positive Contact Indication Bi-stable Clipdication Bi-stable Clip
Technical Specification
Reference Standard IS/IEC 60947-3
No. of Poles 1P, 2P, 3P, 4P
Utilization Category AC 22A
Rated Current (In) 40, 63 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 10000
Operating Temperature -5° C to +55° C
Humidity 95% RH
Terminal Capacity (max) 35 mm2 (up to 63A)
Tightening Torque 2 N-m
Vibration 3 g
Shock Resistance 40mm free fall
Protection Class IP 20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight / Pole in kg 0.090 kg
Dimensions (H x D x W) / Pole in mm 87.5 x 62 x 17.7 mm
Mounting Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material
Busbar Connections Top Side Pin Type
Busbar Connections Bottom Side Pin / Fork Type
53.1 70.817.7
5.3
35.4 50.8
92.8
4462
71.7
4587.5
6.8
42
LEN
GTH
STR
IP
LEN
GTH
STR
IP
ISOLATOR DIMENSIONS (in mm)
![Page 29: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/29.jpg)
5756
Perfection that Matters
ISOLATOR (80A-125A) Technical Specification
Reference Standard IS/IEC 60947-3
No. of Poles 2P, 3P, 4P
Utilization Category AC 22A
Rated Current (In) 80, 100, 125 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 10000
Operating Temperature -5° C to +55° C
Humidity 95% RH
Terminal Capacity (max) 50 mm2
Tightening Torque 2.5 N-m
Vibration g 3 g
Shock Resistance 40 mm free fall
Protection Class IP 20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight in kg 0.158 kg (for 2P), 0.237 kg (for 3P), 0.316 kg (for 4P)
Dimensions (H x D x W) in mm87.5 x 62 x 35.4 mm (for 2P), 87.5 x 62 x 53.1 mm (for 3P),87.5 x 62 x 70.8 mm (for 4P)
Mounting Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material
Busbar Connections Top Side Pin / Fork Type
Busbar Connections Bottom Side Pin / Fork Type
DIMENSIONS (in mm)
35.4
5.3
92.8 4587
.5
44
6.8
50.8
62
73.4
42
53.1 70.8
DIMENSIONS (in mm)
Perfection that Matters
Technical Information
Standard Conformity IS/IEC 60947-5 -1
Contacts
Rated Operation Voltage 240 Vac
Rating Electrical Power 1.2 Watt
Rated Frequency 50 Hz
Terminal Capacity 2.5 mm2
Light Indicaton
Colour
Light Permanent
Source Neon Lamp
Mounting on Din Rail 35 mm x 7.5 mm
Protection Class IP 20
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material.
Ambient Temperature -5 °C to 55 °C
Terminal Capacity: 2.5 mm2
Rated Electrical Power: 3 piece 0.2 W each
Source: LED
INDICATOR LIGHT
8.85 8.85
6.8 63.0
44.0
84.0 35
.5
45.0
64.5
![Page 30: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/30.jpg)
58 59
Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER
Quality Features
Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually
Inscription Window - Ensures circuit identification and hence reduces maintenance downtime
Safety Terminals - They guide the cable towards the cage terminal and avoid improper cable termination
Dual Termination - Two types of busbars can be used, that is, Fork Type and Pin Type
Large Cable Terminals - The terminals are suitable for cables up to 35mm2 cross section area.
Thus making it suitable for copper and aluminium cables
Bi Stable Clip - Every device is provided with a dual position DIN rail clamp. Hence, a device can
be easily changed from a bank of devices connected by a busbar without disturbing your existing wiring
Positive Contact Indication - It clearly indicates contact position through Flag Indication
(Red-ON, Green-OFF) thus enhancing safety
Field fittable Auxiliary Contacts (up to 63 A)
Advance Neutral - where neutral makes ahead of phases and breaks after phases, which ensures
complete discharge of line inductance and capacitance, hence making it suitable as main switch
Test button for regular inspection/testing
General Characteristics
Crabtree introduces the new XPRO range of RCCBs rating from 16 A to 100 A. The range offers a variety of feature benefits such as Conditional Short Circuit Breaking Capacity of 10 kA across the entire range of RCCBs in accordance with IS 12640-1 & IEC 61008, it also incorporates features like Mid Trip - Different knob position to indicate whether the device is switched OFF by a fault or switched OFF manually, Inscription Window, Safety Terminals, Dual Termination, Large Cable Terminals, Bi Stable Clip, Positive Contact Indication, Field fittable Auxiliary Contacts, Test Button for Regular Inspection.
![Page 31: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/31.jpg)
60 61
Perfection that Matters Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
RESIDUAL CURRENT CIRCUIT BREAKER
Technical Specification
Reference Standard IS 12640-1 ; IEC 61008
No. of Poles 2P, 4P
Rated Current (In) 16, 25, 32, 40, 63 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Conditional Short Circuit Current (Inc) 10 kA
Rated Residual Operating Current (I n) 30, 100 & 300 mA
Rated Making Breaking Capacity (Im) 500 A or 10In whichever is greater
Operating Characteristics in presence of Residual Current with d.c. components
‘A’ Type & ‘AC’ Type
Trip Time 1I n < 300ms, 5I n < 40ms
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000
Operating Temperature -25° C to + 55° C
Humidity 95% RH
Terminal Capacity (max) 35 mm2
Tightening Torque 2 N-m
Vibration 3 g
Shock Resistance 40mm free fall
Protection Class IP 20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight in kg 0.215 kg (for 2P) ; 0.335 kg (for 4P)
Dimensions (H x D x W) 87.5 x 62 x 35.9 mm (for 2P) ; 87.5 x 62 x 71.8 mm (for 4P)
Mounting Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material
Busbar Connections Top Side Pin / Fork Type
Busbar Connections Bottom Side Pin / Fork Type
Auxiliary Contacts Yes
PROTECTION
AGAINST ELECTRICAL SHOCK
The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions such as:
1. Breathing 2. Heartbeat
A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results:
500 mA Immediate cardiac arrest resulting in death
70-100 mA Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate. This situation is dangerous since it is irreversible
20-30 mA Muscle contraction can cause respiratory paralysis
10 mA Muscle contraction : the person remains “stuck” to the conductor
1-10 mA Prickling sensations
However, electrical shock should not be viewed in terms of “current” alone, but in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.
The human body has known limits:
Maximum Earth Fault Loop Impedances
Rated res. op. current I n- 5° C25 V
- 5° C50 V
0.03 A 830 1660 0.10 A 250 500 0.30 A 83 166 0.50 A 50 100
AGAINST INDIRECT CONTACT
Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50.
Example
For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666
![Page 32: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/32.jpg)
62 63
Perfection that Matters Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
RCCB Protection at Indirect Contact
Fault resistance
earthing resistance
actual contact voltage
residual (fault) current
rated residual operating current
permissible contact voltage
WORKING PRINCIPLE
Residual current circuit breaker (abbr. RCCB) continuously establish the total of the momentary values of all currents flowing via the active conductors to an electrical installations operated by an earthed AC mains supply. According to Kirchhoff’s first law, this total must always be zero. In the event of a short-to-earth due to defective insulation, such currents will not total zero, because – depending upon the fault resistance RF and the ground circuit resistance RA – a residual current, also called fault current, will not flow via the active conductors but return via the earth to the power supply. If the r.m.s. value of the residual current exceeds the rated residual operating current in the RCCB, then the latter will trigger the disconnection of the installation from the power supply.
AGAINST FIRE
The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp.
The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting.
ACTUATION TIME CHARACTERISTICS
Residual Current Multiple of I n (mA)
I n (mA)
Tim
e (in
ms)
500
300
150
40
0.50 1 2 5 10 20 50
Response time of a non-delayed RCCB as a function of the magnitude of residual current.
RCCB Protection at Direct Contact
L1L2L3N
RCD
Resistance of thehuman body
Resistance at site
Operations earth
R St
RM
RESET FUNCTION
The switch mechanism of RCCBs in XPRO range provides a reset function. The position of the switch lever indicates whether the RCCB has been switched off manually (position O) or as the result of a fault (central position). In order to cancel the central positioning the switch needs first to be moved to position ‘O’, only then can the RCCB be switched on again.
ON POSITION MID POSITION OFF POSITION
ON
RESET
OFF
The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.
WIRING DIAGRAM
Line
Load Load Load
LineLine
![Page 33: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/33.jpg)
64 65
Perfection that Matters Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER
Zone Physiological Effects
Zone 1
Usually no reactions
Zone 2
Usually no harmful physiological effects
Zone 3
Usually no organic damage to be expected. Likelihood of muscular contraction and difficulty in breathing, reversible disturbances of formation and conduction of impulse in the heart and transient cardiac arrest without cardiac fibrillation increases with current magnitude and time.
Zone 4
In addition to the effects of Zone 3, probability if cardiac fibrillation increased upto 5% (curve C2) upto 50% (curve C3) and above 50% beyond curve C3. It increases with magnitude and time, and pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur.
To be within zone of the IEC curve as shown below. It is necessary for the ELCB to operate within 50ms at 240 mA and 150ms at 80mA. Both these conditions are satisfied by 30mA ELCB.
For households, individual outlets, wet areas and temporary installations, ELCB with sensitivity not exceeding 30mA is advisable.
100 mA
A 100mA ELCB will normally give high degree of protection against electrocution but there is a possibility that the shock current could fall below the tripping level of ELCB. This could occur if additional resistances to that of human body are included in the earth path.
The 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance upto 500 Ohms.
300 / 500mA
A 300/500 mA ELCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small. 300/500mA ELCB will not give any protection against electrocution.
SELECTION
30 mA
A 30 mA ELCB will provide a high degree of protection against electrocution in an accidental shock hazard situation. The current flowing through human body could be between 80mA and 240mA depending on the resistance of the human body and the voltage across it.
RCCB - STANDARD APPLICATIONS
at 50 / 60 Hz
currents are not sinusoidal. They are particularly suitable for the following specific applications (dedicated lines) or circuits that may produce DC fault currents, eg variable speed drives with frequency inverters, etc.
DIMENSIONS (in mm)
DIMENSIONS (in mm)
ACCESSORIES
Attachment used for Signalling, Indication, Annunciation and Interlocking.
Technical SpecificationStandard Conformity IS/IEC 60947-1
Current Carrying Capacity (Max) 6 A
Rated Voltage (Ue) 240 Vac
Contact Configuration 1 NO + 1 NC
Utilization Category AC 11
Electrical Endurance (No. of operations) 10000
Terminal Capacity (Max) 6 mm2
Protection Class IP 20 as per IEC-60529/IS-2147
Mounting Left side of RCCB (Field Fittable)
8.85 8.85
11.36.8
16.516.5
S-TYPE AUX
H-TYPE AUX
62.0
44.0
69.8
1.4
87.5
45.0
2.4
11.3
Contact Configuration Current
1NO + 1NC 6 A
Auxiliary Contact
71.8
5.3
92.8 87
.5
42
45
44
50.8
6.8
62
71.7
35.9
STR
IP
LEN
GTH
STR
IP
LEN
GTH
![Page 34: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/34.jpg)
67
Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER
66
Perfection that Matters
Technical Specification
Reference Standard IS 12640-1 ; IEC 61008
No. of Poles 2P, 4P
Rated Current (In) 80, 100 A
Rated Voltage (Ue) 240/415 Vac
Rated Frequency (f) 50 Hz
Rated Conditional Short Circuit Current (Inc) 10 kA
Rated Residual Operating Current (I n) 30, 100 & 300 mA
Rated Making Breaking Capacity (Im) 10In
Operating Characteristics in presence of Residual Current with d.c. components
‘A’ Type & ‘AC’ Type
Trip Time 1I n < 300ms, 5I n < 40ms
Rated Insulation Voltage (Ui) 690 V
Rated Impulse Voltage (Uimp) 4 kV
Dielectric Strength 2.5 kV
Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000
Operating Temperature -25° C to + 55° C
Humidity 95% RH
Terminal Capacity (max) 50 mm2
Tightening Torque 2.5 N-m
Vibration 3 g
Shock Resistance 40mm free fall
Protection Class IP 20
Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)
Net Weight in kg 0.230 kg (for 2P) ; 0.404 kg (for 4P)
Dimensions (H x D x W) in mm 88.2 x 62 x 35.9 mm (for 2P) ; 88.2 x 62 x 71.8 mm (for 4P)
Mounting Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal
Case & Cover Moulded, flame retardant thermoplastic material
Busbar Connections Top Side Pin / Fork Type
Busbar Connections Bottom Side Pin / Fork Type
Auxiliary Contacts No
RESIDUAL CURRENT CIRCUIT BREAKER (80A-100A)
The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link
from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.
WIRING DIAGRAM
Line
Load Load Load
LineLine
72.0 36.0 62.0
44.0
6.8
36.0
71.7
45.0
88.2
5
88.2
5
STR
IP
LEN
GTH
DIMENSIONS (in mm)
![Page 35: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/35.jpg)
69
Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD
AND SHORT CIRCUIT PROTECTION (RCBO)
68
Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD AND SHORT CIRCUIT PROTECTION
CONSTRUCTION
RCBO is a single composite device which provides protection against over currents and earth leakage faults, it comes in the same width and profile as that of a standard MCB. It is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring high degree of protection to the user for a particular circuit. In normal use, it is safe to use and poses no threat to user as well as to environment.
FEATURES
2 for cool running while in operation.
The Functional Earth (FE) white color wire connected to earth provides this protection.
using electronic circuit is set to very precise values and thereby provide greater immunity to nuisance tripping that can be caused by mains borne noise, surge voltages, lighting surges, reactive loads, mains filters, etc.
the trip level to increase. In the case of a N - E fault, the user may have no way of knowing that this fault exists and that the RCBO has been desensitised. Under this condition, the Crabtree VD RCBO provides a far greater level of protection than a normal VI (Voltage Independent) RCBO.
AESTHETICS & CONVENIENCE
2 Module RCBO can simply replace existing MCB 2 pole when upgrading a board.
RELIABILITY & CONTINUITY OF SERVICE
ENERGY LIMITING
Crabtree RCBO meets the requirements for energy let through by IEC & British Standard for energy limiting class 3.
‘A’ TYPE RCBOs
Any electrical appliance with power control has the ability to produce earth fault currents with pulsating DC (rectified AC) components. RCBOs that provide this type of protection are referred to as ‘A’ Type RCBOs.
Standard VI (Voltage Independent) RCBOs do not provide this protection, and are referred to as ‘AC’ Type RCBOs. Crabtree VD RCBOs have been specifically designed to provide protection against pulsating DC fault currents.
Technical Information RCBO (1M) RCBO (2M) RCBO (4M)
Reference Standard IS 12640-2 ; IEC 61009 IS 12640-2 ; IEC 61009 IS 12640-2 ; IEC 61009Type / Series C Curve C Curve C Curve
No. of Poles 1P + Solid Neutral 1P + Switched Neutral (2M) 3P + Switched Neutral (4M)
Rated Current (In)6, 10, 16, 20, 25, 32, 40, 50 A
6, 10, 16, 20, 25, 32, 40 A 6, 10, 16, 20, 25, 32, 40 A
Rated Voltage (Ue) 240 Vac 240 Vac 415 VacRated Frequency (f) 50 Hz 50 Hz 50 HzRated Short Circuit Breaking Capacity 10 kA 10 kA 10 kARated Residual Operating Current (I n) 30 mA 30 mA, 100 mA, 300 mA 30 mA, 100 mA, 300 mARated Making Breaking Capacity (Im) 500 A 500 A 500 A Operating Characteristics in presence of Residual Current with d.c. components
‘A' Type ‘A' Type ‘A' Type
Magnetic Release Setting (5-10)In (5-10)In (5-10)InTrip Time < 40 ms < 40 ms < 40 msRated Insulation Voltage (Ui) 690 V 690 V 690 VRated Impulse Voltage (Uimp) 4 kV 4 kV 4 kVDielectric Strength 2.5 kV 2.5 kV 2.5 kVElectrical / Mechanical Endurance (no. of operations)
2000 / 3000 2000 / 3000 2000 / 3000
Operating Temperature -25° C to + 55° C -25° C to + 55° C -25° C to + 55° CHumidity 95% RH 95% RH 95% RH
Energy Limit Class 3 3 3Terminal Capacity (max) 25 mm2 35 mm2 35 mm2
Tightening Torque 2 N-m 2 N-m 2 N-mVibration 3 g 3 g 3 gShock Resistance 40mm free fall 40mm free fall 40mm free fallProtection Class IP 20 IP 20 IP 20Net Weight in kg 0.200 kg 0.420 kg 0.840 kgDimensions (H x D x W) / Pole 125 x 69.2 x 17.7 mm 87.5 x 68.4 x 35.4 mm 125 x 68.4 x 70.8 mm
MountingClip on DIN Rail (35 mm x 7.5 mm)
Clip on DIN Rail (35 mm x 7.5 mm)
Clip on DIN Rail (35 mm x 7.5 mm)
Installation Position Vertical / Horizontal Vertical / Horizontal Vertical / Horizontal
Case & CoverMoulded, flame retardant thermoplastic material
Moulded, flame retardant thermoplastic material
Moulded, flame retardant thermoplastic material
Busbar Connections Top Side - Pin Type Pin TypeBusbar Connections Bottom Side Pin / Fork Type Pin / Fork Type Pin / Fork TypeN-Flying Lead Length 700 mm - -
![Page 36: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/36.jpg)
70 71
Perfection that Matters Perfection that Matters
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD
AND SHORT CIRCUIT PROTECTION (RCBO)
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD
AND SHORT CIRCUIT PROTECTION (RCBO)
Load Terminal (Phase)
Incoming N-Flying Lead
Load Terminal (Neutral)
FE (Functional Earth) Connection
Test Button
Line Terminal (Phase)
INSTALLATION INSTRUCTIONS FOR 1M RCBO
Monthly Functional Test: Push Test Button, RCBO must trip
Figure 1
Time Current Characteristics C Curve
0.01
0.10
1.00
10.00
100.00
1000.00
10000.00
001011
Multiples of Rated Current
Tim
e (s
ec)
Residual Current Tripping Characteristics
0.01
0.10
1.00
10.00
100.00
1000.00
0.001 0.01 0.1 1 10 100 1000 10000
Rated Residual Current in Amperes
Tim
e (s
ec)
.03
.015
0.015
0.04
TRIPPING CHARACTERISTICS
44
125
44
42
45
6.817.7
69.2
O-OFF
IN
IN
OUT OUTNN L
L
T
FE
Circuit Diagram for 1M RCBO
RCBO (1M)
RCBO (2M) RCBO (4M)
DIMENSIONS (in mm)
![Page 37: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/37.jpg)
Perfection that Matters
THREE PHASE AUTOMATIC CHANGEOVER WITH CURRENT LIMITER (TPN ACCL)
7372
Perfection that Matters
TPN ACCL
The Power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the Residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.
TPN ACCL is a fully automatic high precision microcontroller based device and is ideally suited for proper/efficient utilization of standby generator used in multi-storied apartments, commercial complexes, etc.
Functions-When the Mains Supply is available: Automatic mode: The TPN ACCL allows full load current on each phase when all the 3 phases of mains supply is available, and when any one of the phase fails,
TPN ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply. Manual mode: If R phase is available, it will continue to run the load on main supply irrespective of the availability of other phases. But if R phase fails, the TPN
ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply. Note: It is recommended to connect all essential load to R phase.
- When the Mains supply fails: With AGS (automatic generator start feature): TPN ACCL provides signalling through a potential free contact for starting the Generator.
Without AGS (automatic generator start feature):a. When the mains supply goes OFF, a consumer is automatically connected to the generator in case generator supply is available, after a time
delay of 8-12 seconds in order to limit the sudden load on the generator.
b. The TPN ACCL has a current limiting feature on the generator side. If the load exceeds the allowable limit, TPN ACCL will give a pre-trip indication and after a delay of 5 second, TPN ACCL will trip and goes on hold. After a predetermined time delay (say 8 sec), it will again check the connected load and gives the supply if the load is under the allowable limit. During this period, the consumer is expected to switch off the non-essential loads and reduce it within the limit. The overloaded phase will be indicated through LED.
c. In an unlikely event, if the consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load is automatically disconnected after 5 cycles of interruption.
d. The supply from mains to the load can be restored only after pressing the Reset button present in the front of TPN ACCL.
When Mains supply is restored
a. As soon as the main supply restores, the load is automatically transferred to the mains supply after a delay of 2-4 sec.b. With AGS, TPN ACCL itself generates the signal to automatically stop the generator
TPN ACCLThree Phase Automatic Changeover with Current Limiter
Quality Features
Current limitation on generator side
ACCL TPN/SPN WIRING ARRANGEMENTDURING INSTALLATION
ACCL TPN/TPN WIRING ARRANGEMENT DURING INSTALLATION
Technical Information
Standard Conformity IEC 60947-6-1
No. of Poles 3P+N
Rated current (In)40A/63A/95A on mains, 10-95A on generator
Rated voltage (Ue) 415 / 220 Vac
Rated frequency 50 Hz
Transfer Time 8-12 sec
Restoring Time 2-4 secRated Impulse Voltage (Uimp)
6kV
Utilization Category AC 31A
Class of Equipment PC
Environment B
IndicationMains, Generator, Load, Overload (R,Y,B), mode of operation (auto/manual)
Pollution Degree IIConditional Short Circuit Current
5kA
Ambient Temp. - 5 to + 55 ˚C
Electrical Life 6000 operations
Mounting Surface mounting
Mounting Position Vertical
Terminal Capacity 16 mm2 / 35 mm2
Duty Uninterrupted
Weight 4.5 Kg / 9.4 Kg
Dimensions260 x 243 x 115 mm3
260 x 243 x 150 mm3
383 x 333 x 150 mm3
DIMENSIONS (in mm)
Side Front
BAC
DE
In TPN/SPN, the ACCL will restrict the load if the cumulative current of
all the 3 phases (i.e. R+Y+B) exceeds rated generator current.
Main supply
MCB/RCCB
Load
Generator
L N
SCPD 2
R Y B N
SCPD 1
Auto GEN start control unit
MAINS LOAD IGNGEN
R Y B N R Y B N L N X1 X2
MAINS GEN40A 40A
DHACOTT4040
* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 95A TPN ACCL
In TPN/TPN, the ACCL will restrict the load if the current in any of the phase (i.e. R or Y or B) exceeds rated generator current.
Main supply
MCB/RCCB
Load
Generator
R Y B N
SCPD 2
R Y B N
SCPD 1
Auto GEN start control unit
MAINS LOAD IGNGEN
R Y B N R Y B N R Y B N X1 X2
MAINS GEN40A 40A
DHACOTT4040
* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 95A TPN ACCL
![Page 38: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/38.jpg)
Perfection that Matters
AUTOMATIC SOURCE CHANGEOVER WITH CURRENT LIMITER (SPN ACCL)
7574
Perfection that Matters
SPN ACCL
An indispensable tool to automate power distribution, protect expensive gensets and prevent fatal risks - The power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply, and hence, most of the commercial and residential complexes set-up alternate power sources, such as gensets, to provide efficient back-up for their power needs. However, most of these users of alternate power still depend on manual change-over, which leads to issues such as increased downtime, disruption in key activities as well as critical damage to the expensive equipment and could also prove fatal to the operators.
Crabtree XPRO - Nation’s leading player in power distribution equipment and solutions, now offers Crabtree ACCL, a fully automatic high precision microcontroller based ‘Source Changeover’ device, which also has current limiting function and offers easy and ‘controllable’ changeover between main power supply and generator supply.
With these inherent strengths, Crabtree ACCL is being increasingly adopted by leading power consumers, both at commercial as well as residential levels, as a strong and proven power distribution management tool.
So go ahead, and empower your premises and power distribution with Crabtree ACCL today !
Functions- When the Mains Supply is available:a. The ACCL allows unrestricted supply from Mains in case current is in allowable limits.b. If the current exceed the mains rating, the load is disconnected after a delay of 5 seconds and it will remain disconnected for 8 seconds as a
warning and then automatically reconnects it. During this period, the consumer is expected to switch off the non-essential loads and bring it within the limit.
c. In an unlikely event, if the consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load from the mains is automatically disconnected after 5 cycles of interruption.
d. The supply from mains to the load can be restored after pressing the reset button present in the front of ACCL.
- When the Mains supply fails: Without AGS (automatic generator start features) - When the mains supply goes OFF, a consumer is automatically connected to the generator in
case generator supply is available after a time delay of 8 to 12 seconds in order to limit the sudden load on the generator. With AGS (automatic generator start features) - ACCL Provides signalling through a potential free contact for starting the Generator (Generator
must have control unit for auto Start/off) and then consumer is automatically connected to the generator after a time delay of 8 to 12 seconds in order to limit the sudden load on the generator.
Once the supply goes to generator side then:a. ACCL limits the user from drawing excess load current beyond the pre- set limit. b. If the current exceeds the allowable limit, the ACCL will indicate the overload condition by glowing its “overload” LED. Due to this the load is
disconnected after a delay of 5 seconds and will remain disconnected for 8 seconds as a warning and then automatically reconnects. During this period, the consumer is expected to switch off the non-essential loads and reduce it within the limit.
c. In an unlikely event, if the Consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load from the mains is automatically disconnected after 5 cycles of interruptions.
d. The supply from Gen to the load can be restored only after pressing the Reset button present in the front of ACCL.
SPN ACCLAutomatic Source Changeover with Current Limiter
Quality Features
with neutral isolation
between phase & neutral
ACCL WIRING ARRANGEMENT DURING INSTALLATION
Technical Information
Standard Conformity IEC 60947-6-1
No. of Poles 1P+N
Rated current (In) 30A on mains, 1.5-20A on generator
Rated voltage (Ue) 240 Vac
Rated frequency 50 Hz
Rated insulation voltage 500V
Transfer time 8 to 12 sec
Restoring Time 2 to 4 sec
Utilization Category AC 31A
Class of Equipment PC
Environment B
Indication Mains, Generator, Load, Overload
Ambient Temp. -5 to +55°C
Electrical Life 6000 operations
Rated Impulse Voltage 2.5kV
Duty Uninterrupted
Pollution Degree 2Conditional Short Circuit Current
3kA
Protection Class IP20
Mounting standard mounting RAIL (35x7.5 mm)
Mounting Position Vertical /Horizontal
Terminal Capacity mm² 10
Weight 350 g
71.8
87.5
Front view
36 45
63
44
6.8
Side view
DIMENSIONS (in mm)
L N
Main supply
N L
Input from mains supply
Input from GEN supply
Auto GEN start control unit
GEN with auto start control unit
Ignition signal to remote GEN start terminals
OutputMCB /RCCB
NLoad
ACCL
L
SCPD 1
SCPD 2
Terminals available in ACCL forGEN. ON/OFF feature
* SCPD can be 32A HRC FUSE or 32A MCB
![Page 39: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/39.jpg)
Perfection that Matters
AUTOMATIC CHANGEOVER
7776
Perfection that Matters
Automatic Changeover
The Power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the Residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.
Automatic Changeover is a fully automatic high precision microcontroller based device and is ideally suited for unmanned power transfer operations in bungalows, multi storied appartments, commercial complexes, etc.
Functions- When the Mains Supply is available:a. Automatic Changeover allows full load current when the mains supply is available.b. Thus the load runs on the main supply after a time delay of 2 to 4 seconds
- When the Mains supply fails: With AGS (automatic generator start features)a. Automatic Changeover provides signaling through a potential free contact for starting the Generator. (Generator must have a control unit for auto
start/off) b. A consumer is automatically connected to the Generator supply after a time delay of 12 to 15 seconds in order to limit the sudden load on the
Generator.
Without AGS (automatic generator start features) a. When the mains supply goes off i.e. fails, automatic changeover will automatically sense and actuate the inbuilt changeover mechanism. b. A consumer is automatically connected to the Generator supply after a time delay of 12 to 15 seconds in order to limit the sudden load on the
Generator.
- When the Mains supply is restored:a. On resumption of the mains supply, the load is automatically transferred to the main supply after a time delay of 2 to 4 seconds.
AUTOMATIC CHANGEOVER
Microcontroller Based Design with Complete isolation of Neutral
LED indication of Status
DIN rail mountable, thus saving wall space and wiring
Consumes less power
Automatic Generator ON/OFF facility (on special demand)
Suitable/Compatible with the existing range
Quality Features
AUTOMATIC CHANGEOVER WIRING ARRANGEMENT DURING INSTALLATION
L N
Main supply
N L
Input from mains supply
Input from GEN supply
Auto GEN start control unit
GEN with auto start control unit
Ignition signal to remote GEN start terminals
OutputMCB /RCCB
NLoad
Automatic Changeover
AUTOMATICCHANGEOVER
L
SCPD 1
SCPD 2
Terminals available in Automatic Changeoverwith GEN. ON/OFF features only
Technical Information
Standard Conformity IEC 60947-6-1
No. of Poles 1P+N
Rated current (Ith) 30A
Rated voltage (Ue) 240 Vac
Rated frequency 50 Hz
Rated insulation voltage 500 V
Supply voltage 80-300 Vac
Restoring Time 2 to 4 secMains to Gen transfer time
12 to 15 sec
Rated impulse voltage (Uimp)
2.5 kV
Utilization Category AC 31BConditional short circuit current
3 kA
Indication Mains, Generator, Load
Degree of protection IP-20
Ambient Temp. -5 to +55
Electrical Life 6000 operations
Mounting Standard mounting RAIL (35x7.5 mm)
Mounting Position Vertical /Horizontal
Terminal Capacity mm² 10
Weight 365 gm
Dimensions (in mm) 87.5 x 71.8 x 63 71.8
87.5
Front view
36 45
63
44
6.8
Side view
DIMENSIONS (in mm)
![Page 40: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/40.jpg)
78 79
Perfection that Matters
TIME SWITCH
Quality Features
Digital Time Switch with daily & weekly program
Text oriented user guidance in display
Program repeatability with 8 ON/OFF setting for Digital Programmable & 6 ON/OFF setting for
Astronomical Time Switch
150 hours running reserve for Digital Programmable Time Switch & 24 Hour Programmable
Time Switch & 48 hours running reserve for Astronomical Time Switch
Minimum Switching Time
- 1 Min. for Digital Programmable & Astronomical Time Switch
- 15 Min. for 24 Hour Programmable Time Switch
General CharacteristicsCrabtree introduces the new XPRO range of Time Switches. The range offers a variety of feature benefits such as Controlling the opening and closing of electrical circuits according to a scheduled program, Minimum switching time, Internal battery to enable the timing function in case of power failure, Daily and weekly versions, Simple and compact design.
![Page 41: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/41.jpg)
81
Perfection that Matters
TIME SWITCH
80
Perfection that Matters
Technical Information
Operating Voltage 230 Vac
Rated Frequency 50 – 60 Hz
Width 54.5 mm
Weight 0.2 kg
Installation Type DIN Rail
Type of Contact Changeover Contact
Program Fuctions ON / OFF
Switching Segments 48
Power Reserve 150 Hrs
Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A
Max. Switching Capacity at 250 VAC, cosΦ = 0.6 4 A
Incandescent / Halogen Lamps 1100 watt
Shortest Switching Time 15 Min
Mechanical Life 107
Electrical Life 105
Time Accuracy 1 s/day Quartz
Power Consumption 5 VA
Degree of Protection IP 20
Ambient Temperature -10 ºC to + 55 ºC
24-Hour Analog Time Switch has a 24-hour dial and is used to switch an electrical circuit “ON” or “OFF” at selected times, during a period of time programmed in advance. The start of the programme has to be set on the dial by pulling a segment on the desired time.
Applications: The 24 Hour Analog Time Switch is used in pre-programmed switching of:
ANALOG TIME SWITCH (15 MINUTES)
Load
Main supply220V
01
Quartz
11
1
1 0
24
8
6
10
61214 16
18
3
2022
24
9
1 2 3
L N~
110-230V~50-60Hz
8mm
16(4)250~
2.5mm0.5mm
L N
0
0 0
Load 2Load
Main supply220V
01
Quartz
11
1
1 0
24
8
6
10
61214 16
18
3
2022
24
9
1 2 3
L N~
110-230V~50-60Hz
8mm
16(4)250~
2.5mm0.5mm
L N
0
0 0
Load
Main supply220V
01
Quartz
11
1
1 0
24
8
6
10
61214 16
18
3
2022
24
9
1 2 3
L N~
110-230V~50-60Hz
8mm
16(4)250~
2.5mm0.5mm
L N
0
0 0 66max
36
93m
ax
54max
0
1
Quartz
11
1
1 0
24
8
6
10
61214 16
18
3
2022
24
9
1 2 3
L N~
110-230V~50-60Hz
8mm
16(4) 250~
2.5mm²0.5mm²
L N
0
0 0
For example Consider an Electric Heater in connection with Analog Time Switch
Single Load Multiple Load
Dimension (in mm)
WIRING DIAGRAM
![Page 42: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/42.jpg)
83
Perfection that Matters
TIME SWITCH
82
Perfection that Matters
Technical Information
Operating Voltage 240 Vac
Rated Frequency 50 Hz
Width 36 mm
Weight 0.150 kg
Installation Type DIN Rail
Type of Contact Changeover Contact
Program Weekly Program
Program Fuctions ON / OFF
Number of Memory Locations 56
Power Reserve 150 Hrs
Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A
Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A
Incandescent / Halogen Lamps 2300 watt
Shortest Switching Time 1 Min
Mechanical Life 107
Electrical Life 105
Time Accuracy 1 s/day
Power Consumption 5 VA
Degree of Protection IP 20
Ambient Temperature -10 ºC to + 55 ºC
Time Switches are offered in order to guarantee the opening & closing of electrical circuits according to the scheduled program. Crabtree offers four types of time switches to satisfy the user requirement.
Programmable Time Switch automatically turns lighting or other loads on/off when the programmed on/off time expires. Depending on the day of the week (Mon - Sun) different daily programs can be configured.
Applications: The programmable time switch can be used in pre – programmed switching of:
DIGITAL PROGRAMMABLE TIME SWITCH (WEEKLY)
Load
Main supply220V
Load 1 Load 2
Main supply220V
82
36 66
45.5
Main supply220V
Load
For example Consider an Electric Heater in connection with Programmable Time Switch
Single Load Multiple Load
Dimension
WIRING DIAGRAM
![Page 43: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/43.jpg)
85
Perfection that Matters
TIME SWITCH
84
Perfection that Matters
Technical Information
Operating Voltage 240 Vac
Rated Frequency 50 Hz
Width 36 mm
Weight 0.125 kg
Installation Type DIN Rail
Type of Contact Changeover Contact
Program Fuctions ON / OFF
Number of Memory Locations 54
Power Reserve 48 Hrs
Max. Switching Capacity at 250 VAC, cosΦ = 1 6 A
Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A
Incandescent / Halogen Lamps 1000 watt
Shortest Switching Time 1 Min
Mechanical Life 107
Electrical Life 105
Time Accuracy 2 s/day
Power Consumption < 4 VA
Degree of Protection IP 20
Ambient Temperature -10 ºC to + 40 ºC
Astronomical Programmable Time Switch automatically adjusts the set time along with seasonal variation to control ON/OFF for lighting on purpose of realizing that light is turned on when sun sets & turned off when sun rises.
Applications: The Astronomical Time Switch is used in controlling:
ASTRONOMICAL PROGRAMMABLE TIME SWITCH (WEEKLY)
Load
Main supply220V
Load 1 Load 2
Main supply220V
Main supply220V
LoadLoad 82
36 66
45.5
Single Load Multiple Load
For example Consider an Electric Bulb in connection withAstronomical Programmable Time Switch
Dimension
WIRING DIAGRAM
![Page 44: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/44.jpg)
87
Perfection that Matters
TIME SWITCH
86
Perfection that Matters
Technical Information
Operating Voltage 240 Vac
Rated Frequency 50 Hz
Width 17.5 mm
Weight 0.075 kg
Installation Type DIN Rail
Adjustment Range 0.5 - 20 Min
Type of Contact NO Contact
Type of Connection 3-/4- conductor
Max. Switching Capacity at 250 Vac, cosΦ = 1 16 A
Max. Switching Capacity at 250 Vac, cosΦ = 0.6 10 A
Incandescent / Halogen Lamps 2300 watt
Switch for Permanent Light Sliding Switch
Degree of Protection IP 20
Ambient Temperature -10 ºC to + 55 ºC
Staircase Light Time Switch is a variable delay timer to control stairwell lighting. A momentary action push button will initiate its output, which will then ‘time out’ after a pre – set delay has elapsed.
Applications: The Staircase Light Time Switch is specifically used in controlling stairwell lighting in multiplexes, hotels, offices etc.
STAIRCASE LIGHT TIME SWITCH
85 45
17.560
44
Switch 1
Bulb 2
Main supply220V
Bulb 3
Bulb 1
Switch 2
Switch 3
DimensionFor example
WIRING DIAGRAM3 Wire Connection 4 Wire Connection
![Page 45: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/45.jpg)
89
Perfection that Matters
TIME SWITCH
88
Perfection that Matters
Technical Information
Operating Voltage 220 - 240 Vac
Rated Frequency 50 Hz
Width 54.5 mm
Weight 0.2 kg
Installation Type DIN Rail
Type of Contact Changeover Contact
Program Fuctions ON / OFF
Number of Memory Locations 48
Power Reserve 150 Hrs
Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A
Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A
Incandescent / Halogen Lamps 2300 watt
Shortest Switching Time 15 Min
Mechanical Life 107
Electrical Life 105
Time Accuracy 1 s/day
Power Consumption 5 VA
Degree of Protection IP 20
Ambient Temperature -10 ºC to + 55 ºC
24 Hour Programmable Time Switch has a 24h dial and is used to switch an electrical circuit “ON” or “OFF” at selected times during a period of time programmed in advance. A program consists of a closing time and an opening time for a circuit.
Applications: The 24 Hour Programmable Electronic Time Switch is used in pre – programmed switching of:
24 HOUR PROGRAMMABLE TIME SWITCH
Load 1 Load 2
Main supply220V
Load
Main supply220V
Main supply220V
Load
4585
54.5
20
6649
Single Load Multiple Load
Dimension
WIRING DIAGRAM
For example Consider an Electric lamp in connection with24 Hour Programmable Time Switch
![Page 46: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/46.jpg)
90
Perfection that Matters
Distribution Boards at Glance
91
Perfection that Matters
POWER SERIES DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS
SPN Double Door Distribution BoardTPN Per Phase Isolation Double Door Distribution Board
TPN Double Door Vertical Distribution Board
SPN Double Door Distribution Board
TPN Double Door Horizontal Distribution Board
8 - Segment Double Door Distribution Board
Automatic Phase Selector Double Door Distribution Board with 32A Automatic Phase Selector
Phase Selector Double Door Horizontal Distribution Board with 40/ 63A Rotary Switch
No. of Ways 4, 6, 8, 12 & 16 Ways 2+4, 2+6, 2+8 & 2+12 Ways 4, 8 & 12 Ways 4, 6, 8, 12 & 16 Ways 4, 6, 8 & 12 Ways 4, 6, 8 & 12 Ways 4 & 6 Ways 4,6 & 8 Ways
Type of Installation Surface Flush / Surface Surface Flush / Surface Flush / Surface Flush / Surface Flush / Surface Surface
Colour / Finish Bucket White / Texture Finish Bucket White / Texture Finish Bucket White / Texture Finish Bucket White / Texture FinishBucket White / Texture Finish
Bucket White / Texture Finish
Bucket White / Texture FinishBucket White / Texture Finish
Door Options Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version
Sheet Thickness (mm)
1.0 mm 1.0 mm 1.2 mm 1.0 mm 1.0 mm 1.2 mm 1.0 mm 1.0 mm
Door Locking Options
Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock
Removable Gland Plates
Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom
Protection Level of Distribution Boards
Advanced Advanced Advanced Standard Standard Standard Advanced Standard
Distribution Technique
Straight Busbar Straight Busbar Fish-bone Busbar Straight Busbar Straight Busbar Straight Busbar Straight Busbar Straight Busbar
Busbar Rating 100 A 125 A 125 A 100 A 100 A 100 A 125 A 100 A
Busbar Short Time Withstand (Icw)
5 kA for 0.1 second 5 kA for 0.1 second 10 kA for 0.5 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second
Busbar Conditional Short Circuit (Ics)
15 kA 10 kA 25 kA 10 kA 10 kA 10 kA 10 kA 10 kA
Incoming Max. 100 A Max. 100 A Max. 125 A Max. 100 A Max. 100 A Max. 63 A per phase Max. 63 A Max. 63 A per phase
Outgoing Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 32 A Max. Individual 32 A
Voltage Rating 240 Vac, 1 Phase 240-415 Vac, 3 Phase / 4 Wire 240-415 Vac, 3 Phase / 4 Wire 240 Vac, 1 Phase240-415 Vac, 3 Phase / 4 Wire
240-415 Vac, 3 Phase / 4 Wire
240-415 Vac, 3 Phase / 4 Wire
240-415 Vac, 3 Phase / 4 Wire
Incoming OptionsUp to 100 A Isolator (2P) or 100 A RCCB (2P)
100 A Isolator (4P) or 100 A RCCB (4P)
Up to 125 A Isolator (4P, 3P & 2P) or 100 A RCCB
100 A Isolator (2P) or 100 A RCCB (2P)
100 A Isolator (4P) ; 100A RCCB
100 A Isolator (4P) & 100 A RCCB (4P) or RCBO (4P)
63 A Isolator or 63 A RCCB & 63 A MCB
100 A Isolator & R, Y, B Indicating Lights (3P+N) & 100 A RCCB
Residual Current Protective Devices Options
RCCB as Incomer / RCBO as Outgoing
RCCB as Incomer / RCBO as Outgoing
RCCB as Incomer / RCBO as Outgoing
RCCB or RCBO as IncomerRCCB or RCBO as Incomer
RCCB or RCBO as Incomer
RCCB or RCBO as Incomer RCCB or RCBO as Incomer
Neutral Bar Terminal Capacity
25 mm2 25 mm2 25 mm2, Split on both sides 16 mm2 16 mm2 16 mm2 25 mm2 16 mm2
Earthing Bar Terminal Capacity
25 mm2 25 mm2 25 mm2, Split on both sides 16 mm2 16 mm2 16 mm2 25 mm2 16 mm2
Index of Protection (IP)
IP 2X / IP 42 IP 2X / IP 42 IP 2X / IP 42 IP 43 IP 43 IP 42 IP 2X / IP 42 IP 42
Insulation Voltage (Ui)
690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac
Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Ambient Temperature
-5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C
Distribution Board - Reference Standard
IS 8623 ; IS 13032 ; IEC 61439-3 IS 8623 ; IS 13032 ; IEC 61439-3 IS 8623 ; IS 13032 ; IEC 61439-3IS 8623 ; IS 13032 ; IEC 61439-3
IS 8623 ; IS 13032 ; IEC 61439-3
IS 8623 ; IS 13032 ; IEC 61439-3
IS 8623 ; IS 13032 ; IEC 61439-3
IS 8623 ; IS 13032 ; IEC 61439-3
Protective Devices - Reference Standard
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3
Residual Current Protective Devices - Reference Standard
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009
Index of Protection (IP) - Reference Standard
IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529
![Page 47: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/47.jpg)
92 93
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
XPRO Classique Distribution board*
NO. OF WAYS I/C+O/G CAT NO. (DD)
TPN TPN TPN
4 8+12 DCDKTHODCW04
6 8+18 DCDKTHODCW06
8 8+24 DCDKTHODCW08
12 8+36 DCDKTHODCW12
- - -
NO. OF WAYS I/C+O/G CAT NO. (DD)
SPN SPN SPN
4 4 DCDKSHODCW04
6 6 DCDKSHODCW06
8 8 DCDKSHODCW08
12 12 DCDKSHODCW12
16 16 DCDKSHODCW16
NO. OF WAYS I/C+O/G CAT NO. (DD)
SPN SPN SPN
4 4 DCDKSHCDXW04
6 6 DCDKSHCDXW06
8 8 DCDKSHCDXW08
12 12 DCDKSHCDXW12
16 16 DCDKSHCDXW16
NO. OF WAYS I/C+O/G CAT NO. (DD)
TPN TPN TPN
4 8+12 DCDKTHCDXW04
6 8+18 DCDKTHCDXW06
8 8+24 DCDKTHCDXW08
12 8+36 DCDKTHCDXW12
- - -
Classique - II Distribution Board - SPN
Classique - II Distribution Board - TPN
Classique Distribution Board - TPN
Classique Distribution Board - SPN
XPRO Classique Distribution board*
NO. OF WAYS I/C+O/G CAT NO. (DD)
4 8+12 DCDKTHPDXW04
6 8+18 DCDKTHPDXW06
8 8+24 DCDKTHPDXW08
TP&N PPI Distribution Board
NO. OF WAYS CAT NO. (DD)
4 DCDKTHDDCW04
6 DCDKTHDDCW06
8 DCDKTHDDCW08
12 DCDKTHDDCW12
8 Segment DD Distribution BoardIP 42 Double Door DB; Steel Sheet, Phosphatised, powder Painted MCB distribution Board with Busbar, neutral link, Earth Bar and Din Rail. As per Tamilnadu Inspectorate specification
NO. OF WAYS Rating * ** CAT NO. (DD)
4 32A* DCDAKHDCZ04032
6 32A* DCDAKHDCZ06032
Classique Plus Automatic Phase Selector DB
Note: Supplied with 63 A, 4 P MCB as incomer.* Changeover Capacity Per Phase** 63A Current Carrying Capacity Per Phase
NO. OF WAYS Rating CAT NO. (DD)
4 40 DCDSMACCZ04040
4 63 DCDSMACCZ04063
6 40 DCDSMACCZ06040
6 63 DCDSMACCZ06063
8 40 DCDSMACCZ08040
8 63 DCDSMACCZ08063
Classique Plus Manual Phase Selector Horizontal DBFitted with 3nos Rotary switch
![Page 48: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/48.jpg)
94 95
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
XPRO Classique Distribution board*
DESCRIPTION CAT NO.
20 A DP PLUG ASSEMBLY SPLX0035
20 A DP SOCKET ASSEMBLY SPLX0036
30 A TP PLUG ASSEMBLY SPLX0037
30 A TP SOCKET ASSEMBLY SPLX0038
Plug & SocketXPRO Spares
Plug & Socket Board
AMP DESCRIPTION CAT NO. (DD)
20 SPN DCDPUSN020
20 DP DCDPUDN020
30 TPN DCDPUTN030
MCB Enclosure Plastic
NO. OF POLES DESCRIPTION CAT NO.
2 PLASTIC DCDEPDP
4 PLASTIC DCDEPFP
MCB Enclosure Steel
NO. OF POLES DESCRIPTION CAT NO.
2 SS DCDESDP
4 SS DCDESFP
Timer Distribution Board
DESCRIPTION CAT NO. (DD)
TPN Timer Classique DB with Timer Switch DCDIN002
Modular Contactor TPN 40A
DESCRIPTION CAT NO. (DD)
Modular Contactor TPN 40A DSCPGMDBX436
XPRO Power Series Distribution board*
NO. OF WAYS I/C+O/G CAT NO. (DD)
4 4 DCDMSHODCW04
6 6 DCDMSHODCW06
8 8 DCDMSHODCW08
12 12 DCDMSHODCW12
16 16 DCDMSHODCW16
TP&N PPI Distribution Board
NO. OF WAYS I/C+O/G CAT NO. (DD)
2+4 4+6+12 DCDKTHPDCW04
2+6 4+6+18 DCDKTHPDCW06
2+8 4+6+24 DCDKTHPDCW08
2+12 4+6+36 DCDKTHPDCW12
Per Phase Isolation (PPI) Vertical - 4 Tier
NO. OF WAYS CAT NO. Isolator I/C** CAT NO. MCB I/C***
4 DCDKTVODCW04 DCDLVDCBMAFC04
8 DCDKTVODCW08 DCDLVDCBMAFC08
12 DCDKTVODCW12 DCDLVDCBMAFC12
TP&N Vertical
** Suitable for MCB/Isolator as I/C upto 63A*** Suitable for MCB as I/C upto 80-125A
NO. OF WAYS CAT NO.* DESCRIPTION
4 DCDLVDCBGSTE04 Suitable For FP ‘G’ Frame’ MCCB
8 DCDLVDCBGSTE08 Suitable For FP ‘G’ Frame’ MCCB
12 DCDLVDCBGSTE12 Suitable For FP ‘G’ Frame’ MCCB
FP Vertical (with MCCB as Incomer)
* Suitable for MCCB as I/C upto 160A, for appropriate MCCB price, please see Havells IP Price list
NO. OF WAYS CAT NO. (DD)
4 DCDLVDCBGHFO04
6 DCDLVDCBGHFO06
8 DCDLVDCBGHFO08
12 DCDLVDCBGHFO12
TPN Vertical Load Line
NO. OF WAYS CAT NO. (DD)
2 X 13 DCDKTHZDCW13
3 X 13 DCDKTHYDCW13
4 X 13 DCDKTHXDCW13
Flexy Double Door Distribution Board
![Page 49: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/49.jpg)
96 97
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
SP ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCSPF0x5-005
6-32 DCMJCSPF006-032
40 DCMJCSPF040
50 DCMJCSPF050
63 DCMJCSPF063
DP ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCDPF0x5-005
6-32 DCMJCDPF006-032
40 DCMJCDPF040
50 DCMJCDPF050
63 DCMJCDPF063
TP ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCTPF0x5-005
6-32 DCMJCTPF006-032
40 DCMJCTPF040
50 DCMJCTPF050
63 DCMJCTPF063
FP ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCFPF0x5-005
6-32 DCMJCFPF006-032
40 DCMJCFPF040
50 DCMJCFPF050
63 DCMJCFPF063
SP&N ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCSNF0x5-005
6-32 DCMJCSNF006-032
40 DCMJCSNF040
50 DCMJCSNF050
63 DCMJCSNF063
TP&N ‘C’ Curve Series
RATING CODE
0.5-5 DCMJCTNF0x5-005
6-32 DCMJCTNF006-032
40 DCMJCTNF040
50 DCMJCTNF050
63 DCMJCTNF063
MCB Higher Rating DP ‘C’ Series
RATING CODE
80 DCMJCDPF080
100 DCMJCDPF100
125 DCMJCDPF125
MCB Higher Rating TP ‘C’ Series
RATING CODE
80 DCMJCTPF080
100 DCMJCTPF100
125 DCMJCTPF125
MCB Higher Rating FP ‘C’ Series
RATING CODE
80 DCMJCFPF080
100 DCMJCFPF100
125 DCMJCFPF125
RATING CODE
80 DCMJCSPF080
100 DCMJCSPF100
125 DCMJCSPF125
MCB Higher Rating SP ‘C’ Series
![Page 50: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/50.jpg)
98 99
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
MCB SP ‘D’ Series
RATING CODE
0.5-5 DCMJDSPF0x5-005
6-32 DCMJDSPF006-032
40 DCMJDSPF040
50 DCMJDSPF050
63 DCMJDSPF063
MCB DP ‘D’ Series
RATING CODE
0.5-5 DCMJDDPF0x5-005
6-32 DCMJDDPF006-032
40 DCMJDDPF040
50 DCMJDDPF050
63 DCMJDDPF063
MCB TP ‘D’ Series
RATING CODE
0.5-5 DCMJDTPF0x5-005
6-32 DCMJDTPF006-032
40 DCMJDTPF040
50 DCMJDTPF050
63 DCMJDTPF063
MCB FP ‘D’ Series
RATING CODE
0.5-5 DCMJDFPF0x5-005
6-32 DCMJDFPF006-032
40 DCMJDFPF040
50 DCMJDFPF050
63 DCMJDFPF063
RATING CODE
40 DCMFOSPX040
63 DCMFOSPX063
Isolator SP
RATING CODE
80 DCMFODPX080
100 DCMFODPX100
125 DCMFODPX125
Higher Rating Isolator DP
RATING CODE
80 DCMFOFPX080
100 DCMFOFPX100
125 DCMFOFPX125
Higher Rating Isolator FP
RATING CODE
80 DCMFOTPX080
100 DCMFOTPX100
125 DCMFOTPX125
Higher Rating Isolator TP
RATING CODE
40 DCMFODPX040
63 DCMFODPX063
Isolator DP
RATING CODE
40 DCMFOTPX040
63 DCMFOTPX063
Isolator TP
RATING CODE
40 DCMFOFPX040
63 DCMFOFPX063
Isolator FP
![Page 51: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/51.jpg)
100 101
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
DESCRIPTION CODE
30A W/O GEN START/STOP DCAAOSN3030
30A with GEN START/STOP DCAAWSN3030
Automatic Changeover
TPN ACCLTPN ACCL (TPN/SPN) (Automatic Source Changeover with Current Limiter)
GEN RATING
DESCRIPTIONCAT. NO. WITHOUT GEN START/STOP
CAT. NO. WITH GEN START/STOP
20A 40A/20A TPN/SPN ACCL DCACOTN4020 DCACWTN4020
25A 40A/25A TPN/SPN ACCL DCACOTN4025 DCACWTN4025
30A 40A/30A TPN/SPN ACCL DCACOTN4030 DCACWTN4030
40A 40A/40A TPN/SPN ACCL DCACOTN4040 DCACWTN4040
20A 63A/20A TPN/SPN ACCL DCACOTN6320 DCACWTN6320
25A 63A/25A TPN/SPN ACCL DCACOTN6325 DCACWTN6325
30A 63A/30A TPN/SPN ACCL DCACOTN6330 DCACWTN6330
40A 63A/40A TPN/SPN ACCL DCACOTN6340 DCACWTN6340
63A 80A/63A TPN/SPN ACCL DCACOTN8063 -
TPN ACCL (TPN/TPN) (Automatic Source Changeover with Current Limiter)
GEN RATING
DESCRIPTIONCAT. NO. WITHOUT GEN
START/STOPCAT. NO. WITH GEN
START/STOP
20A 40A/20A TPN/TPN ACCL DCACOTT4020 DCACWTT4020
25A 40A/25A TPN/TPN ACCL DCACOTT4025 DCACWTT4025
30A 40A/30A TPN/TPN ACCL DCACOTT4030 DCACWTT4030
40A 40A/40A TPN/TPN ACCL DCACOTT4040 DCACWTT4040
20A 63/20A TPN/TPN ACCL DCACOTT6320 DCACWTT6320
25A 63/25A TPN/TPN ACCL DCACOTT6325 DCACWTT6325
30A 63/30A TPN/TPN ACCL DCACOTT6330 DCACWTT6330
40A 63/40A TPN/TPN ACCL DCACOTT6340 DCACWTT6340
63A 80/63A TPN/TPN ACCL DCACOTT8063 -
SPN ACCL (Automatic Source Changeover with Current Limiter)
GEN RATING DESCRIPTIONCAT. NO. WITHOUT GEN START/STOP
CAT. NO. WITH GEN START/STOP
SPN 1.5 (300W) 30A/1.5A ACCL DCABOSN301X -
SPN 2.5 (500W) 30A/2.5A ACCL DCABOSN302X -
SPN 3 (600W) 30A/03A ACCL DCABOSN3003 DCABWSN3003
SPN 4 (800W) 30A/04A ACCL DCABOSN3004 -
SPN 5 (1000W) 30A/05A ACCL DCABOSN3005 -
SPN 6 (1200W) 30A/06A ACCL DCABOSN3006 DCABWSN3006
SPN 9 (1800W) 30A/09A ACCL DCABOSN3009 DCABWSN3009
SPN 12 (2400W) 30A/12A ACCL DCABOSN3012 DCABWSN3012
SPN 15 (3000W) 30A/15A ACCL DCABOSN3015 DCABWSN3015
SPN 20 (4000W) 30A/20A ACCL DCABOSN3020 DCABWSN3020
DP RCCB ‘AC’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
16 DCRJCMDF030016 DCRJCMDF100016 DCRJCMDF300016
25 DCRJCMDF030025 DCRJCMDF100025 DCRJCMDF300025
32 DCRJCMDF030032 DCRJCMDF100032 DCRJCMDF300032
40 DCRJCMDF030040 DCRJCMDF100040 DCRJCMDF300040
63 DCRJCMDF030063 DCRJCMDF100063 DCRJCMDF300063
FP RCCB ‘AC’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
25 DCRJCMFF030025 DCRJCMFF100025 DCRJCMFF300025
40 DCRJCMFF030040 DCRJCMFF100040 DCRJCMFF300040
63 DCRJCMFF030063 DCRJCMFF100063 DCRJCMFF300063
DP RCCB ‘A’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
16 DCRJAMDF030016 DCRJAMDF100016 DCRJAMDF300016
25 DCRJAMDF030025 DCRJAMDF100025 DCRJAMDF300025
32 DCRJAMDF030032 DCRJAMDF100032 DCRJAMDF300032
40 DCRJAMDF030040 DCRJAMDF100040 DCRJAMDF300040
63 DCRJAMDF030063 DCRJAMDF100063 DCRJAMDF300063
DP Higher Rating RCCB ‘AC’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
80 DCRJCMDF030080 DCRJCMDF100080 DCRJCMDF300080
100 DCRJCMDF030100 DCRJCMDF100100 DCRJCMDF300100
FP RCCB ‘A’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
16 DCRJAMFF030016 DCRJAMFF100016 DCRJAMFF300016
25 DCRJAMFF030025 DCRJAMFF100025 DCRJAMFF300025
32 DCRJAMFF030032 DCRJAMFF100032 DCRJAMFF300032
40 DCRJAMFF030040 DCRJAMFF100040 DCRJAMFF300040
63 DCRJAMFF030063 DCRJAMFF100063 DCRJAMFF300063
FP Higher Rating RCCB ‘AC’ Type
RATING 30mA CODE 100mA CODE 300mA CODE
80 DCRJCMFF030080 DCRJCMFF100080 DCRJCMFF300080
100 DCRJCMFF030100 DCRJCMFF100100 DCRJCMFF300100
![Page 52: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/52.jpg)
102 103
Product ProductOrdering information Ordering information
Perfection that MattersPerfection that Matters
RATING SENSITIVITY CODE
6A 30mA DCBJACSP1030006
10A 30mA DCBJACSP1030010
16A 30mA DCBJACSP1030016
20A 30mA DCBJACSP1030020
25A 30mA DCBJACSP1030025
32A 30mA DCBJACSP1030032
40A 30mA DCBJACSP1030040
50A 30mA DCBJACSP1030050
RCBO - A Type (SP&N -1M)
RCBO - A Type (SP&N - 2M)
RCBO - A Type (TP&N - 4M)
RATING 30mA CODE 100mA CODE 300mA CODE
6A DCBJACSN2030006 DCBJACSN2100006 DCBJACSN2300006
10A DCBJACSN2030010 DCBJACSN2100010 DCBJACSN2300010
16A DCBJACSN2030016 DCBJACSN2100016 DCBJACSN2300016
20A DCBJACSN2030020 DCBJACSN2100020 DCBJACSN2300020
25A DCBJACSN2030025 DCBJACSN2100025 DCBJACSN2300025
32A DCBJACSN2030032 DCBJACSN2100032 DCBJACSN2300032
40A DCBJACSN2030040 DCBJACSN2100040 DCBJACSN2300040
RATING 30mA CODE 100mA CODE 300mA CODE
6A DCBJACTN4030006 DCBJACTN4100006 DCBJACTN4300006
10A DCBJACTN4030010 DCBJACTN4100010 DCBJACTN4300010
16A DCBJACTN4030016 DCBJACTN4100016 DCBJACTN4300016
20A DCBJACTN4030020 DCBJACTN4100020 DCBJACTN4300020
25A DCBJACTN4030025 DCBJACTN4100025 DCBJACTN4300025
32A DCBJACTN4030032 DCBJACTN4100032 DCBJACTN4300032
40A DCBJACTN4030040 DCBJACTN4100040 DCBJACTN4300040
Auxiliary Contact For RCCB
DESCRIPTION CODE
1NO +NC (H &S) DSSRCX0027
Staircase Light Time Switch (0.5-20min)
S. NO. PRODUCT CODE
1 24 Hour Analog Time Switch (SST* - 15 min) DCTED15016
Staircase Light Time Switch (0.5-20min)
S. NO. PRODUCT CODE
1 Staircase Light Time Switch(0.5-20min) DCTCNx5016
24 Hour Programmable Time Switch
S. NO. PRODUCT CODE
1 Programmable Time Switch 24 Hrs DCTDD15016
Digital Programmable Time Switch
S. NO. PRODUCT CODE
1 Digital Time Switch with Weekly Program DCTAW01016
Astronomical Time Switch
S. NO. PRODUCT CODE
1 Astronomical Weekly Prog. Time Switch DCTBW01006
![Page 53: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/53.jpg)
105
Perfection that Matters
104
ProductOrdering information
Perfection that Matters
Indicator Light 1 Phase
COLOUR CODE
Red DCMJYSPX000
Green DCMJZSPX000
Blue DCMJVSPX000
Amber DCMJXSPX000
Clear DCMJWSPX000
Auxiliary Contact For MCB
DESCRIPTION CODE
1NO +NC (H &S) DSSMCX0190
Shunt Trip
RATING CODE
12V DCMJCDPF03221
24V DCMJCDPF03222
48V DCMJCDPF03223
240Vac DCMJCDPF03224
Indicator Light 3 Phase
COLOUR CODE
Red, Yellow, Blue DCMJWTPX000
Notes
![Page 54: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/54.jpg)
106
Perfection that Matters
Notes
![Page 55: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4](https://reader036.vdocument.in/reader036/viewer/2022071013/5fcb43fcdbc53364a7300248/html5/thumbnails/55.jpg)
Havells India Ltd.Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-3331000 Email: [email protected], www.crabtreeindia.com Consumer Care No.: 1800 11 0303 (Tollfree),011-4166 0303 (Landline), 1800 103 1313 (All Connections)Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!CIN - L31900DL1983PLC016304
ZCE
PL0
0005
/AU
G16
/JU
NE
17
Regional & Branch Offices:
NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-3331000, Delhi: Tel: 011-47676700, 23888200, Chandigarh: Tel: 0172-4232400-401, Dehradun: Tel: 0135-6670202, Noida / Haryana: Tel: 0120-3331000, Ludhiana: Tel: 0161-4676000 / 24, Jammu: Tel: 0191-2478330, 2479330, Sri Nagar: Tel: 0194-2490431, Jaipur: Tel: 0141-3914645, 3988210 Jodhpur: Tel: 0291-9214201640 / 45, Lucknow: Tel: 0522-6672100, Kanpur: Tel: 0512-6710400, 6710409
EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52, Bhubaneshwar: Tel: 0674- 668101/102/103/104, Guwahati: Tel: 0361-2134521, 2458923, 2460355, Siliguri: Tel: 0353-2525907, Ranchi: 0651-2244861, 2244862, 2244864, 2244868, 2244869, Jamshedpur: Tel: 0657-6542492, 09234369436, Patna: Tel: 0612-2207221, 2207222, 2207223, 2655518
WEST - REGIONAL OFFICE: Mumbai: 1271, Solitaire Corporate Park, Bldg. No. 12, 7th Floor, Andheri - Ghatkopar Link Road, Chakala, Andheri (East), Mumbai-
400093. Ph.: 022 - 67298600-602 Ahmedabad: Tel: 079-40061111, 40060738-740, Indore: Tel: 0731-2572340-41, 4009998 (Airtel), Rajkot: Tel: 0281-2481112, 2921212, Nagpur: Tel: 0712-2240932, 2242692, 2242699 Pune: Tel: 020-64016413 / 14, Raipur: Tel: 0771-4243400 / 01, Surat: Tel: 0261-2350137, 9979890137, Jabalpur: Tel: 0761-4064491
SOUTH - REGIONAL OFFICE: Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008, Tel: 044-42280600, 605, Bangalore: Tel: 080-49075000, Coimbatore: Tel: 0422-4550200, 2305199, 2306199, Hyderabad: Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Kochi: Tel: 0484-4099000, Vizag: Tel: 0891-6514339, Vijayawada: Tel: +91-9247058847/57, Calicut: 0495-4019194, Madurai: 0452-4267022, Trivandrum: 0471-4015323, Hubli: 0836-4248600, Trichy: 09944460160