Page 1: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

Switchgear Range Catalogue 2017

Page 2: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

When aesthetics come together with state-of-the-art technology, you get a product as refined as

Crabtree. Crabtree modular switches have been adorning walls in homes and offices for years. Our

endeavour is to always create products that adhere to the highest engineering standards.

Crabtree is introducing a new category of switchgear - XPRO, a smart and efficient range of

products that are designed to stand the test of time.

This user friendly range offers enhance safety and is designed to meet regular as well as customer

specific requirements

High professionalism & product quality have made Crabtree a distinguished company. Production

here is a symbiosis between advanced technology, maximum functionality and aesthetic designing

to match the taste of the discerning clientele.

Today, Crabtree is committed to meeting the challenges of the new economy through business

ethics, global reach and technological expertise.

Contents

Power Series Distribution Boards

Classique Distribution Boards

Miniature Circuit Breaker

Isolator

Residual Current Circuit Breaker

Residual Current Circuit Breaker With Overload and Short Circuit Protection

Automatic Changeover

Time Switch

Distribution Boards at Glance

Product Ordering Information

04

14

30

44

48

58

62

68

78

80

Perfection that Matters

Page 3: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

4 5

Perfection that Matters

General Characteristics

Crabtree introduces the new XPRO Power series of Distribution Boards with increased safety, meeting the International standards. The range offers a variety of feature benefits, such as Conditional short circuit rating of 15kA in SPN DB and 25kA in TPN DB in accordance with IS 13032, BS EN 60439-3, Shrouding on all phase/ neutral terminals along with physically isolable neutral link, High integrity/Clean earth kit for electronic/ IT installations, Ample space for wiring and proper distribution of neutral & earth wire.

POWER SERIES DISTRIBUTION BOARDS

Quality Features

Modern styling allows the range to discreetly blend in with both industrial and commercial premises

Shrouded terminals for Phase/ Neutral ensure complete safety against any accidental touch of live parts by servicing personnel

Multi-fold design technology in fabrication from single sheet steel lends ruggedness and structural strength

Generous wiring space. 25mm2 of terminal capacity for earth & neutral bars and dual earth and neutral bars provided on TPN

Distribution Boards for ease of installation, makes it a user friendly design

Provision of Clean Earth (High Integrity Earthing) kit for electronic ( IT ) installations in TPN Distribution Board

Removable Main busbar/ Pan Assembly in SPN/TPN Distribution Board to aid installation.

Main earth stud allows earth to be terminated inside or outside the enclosure

The door when locked (with barrel lock) covers all devices and front cover screws to prevent unwanted access

Physically isolable neutral link is provided to carry out insulation test in TPN Distribution Boards

Page 4: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

76

Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS

TPN Vertical Load Line

DIMENSIONS (in mm)

TPN Vertical Load Line

405

395335

A B C

125

127

3

Technical Specification

No. of Ways 4, 6, 8 & 12 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Snap Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Fish-bone Busbar

Busbar Rating 160 A

Busbar Short Time Withstand (Icw) 10 kA for 0.5 second

Busbar Conditional Short Circuit (Ics) 25 kA

Incoming Max. 160 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options G Frame MCCB 160 A (3P or 3P+N)

Residual Current Protective Devices Options MCB / RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2, Split on both sides

Earthing Bar Terminal Capacity 25 mm2, Split on both sides

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529t

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM SIDE

(EACH SIDE)Ø31 Ø31 Ø50

4 570 560 494

6 4 1 26 624 614 548

8 678 668 602

12 778 776 710

Page 5: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

98

Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS

Flexy Double Door Distribution Board

DIMENSIONS (in mm)

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM SIDE

(EACH SIDE)Ø31 Ø31

2 X 13 295 400 428

6 6 23 X 13 453 558 586

4 X 13 591 666 694

Flexy Double Door Distribution Board

307395

3801911

428

BC A

Technical Specification

No. of Ways 2 X 13W, 3 X 13W & 4 X 14W

Type of Installation Flush / Surface

Door Options Rectangular

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 VAC, 3 Phase / 4 Wire

Incoming Options As per site requirement i.e., 100 A Isolator (4P); 100 A RCCB

Earth Leakage Protective Devices RCCB / RCBO

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 VAC

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 13032 ; IEC 60439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS/IEC 61009 ; IS/IEC 61008

Index of Protection (IP) - Reference Standard IS/IEC 60529t

Page 6: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

10 11

Perfection that Matters Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS

SP&N DISTRIBUTION BOARD

Fully shrouded neutralbusbar for increased safety

Combination screw headson all devices

Easy access earth bar canaccommodate up to

25mm2 cables

Stand-off foot form forstable installation

High quality clear subcircuit identification labels

Removable gland platestop/bottom for ease ofinstallation

New 100A SwitchDisconnector incomer options

180°opening for easy access

Cover screwed by meansof combination screws

SP&N DISTRIBUTION BOARD

DIMENSIONS (in mm)

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM

Ø31 Ø31

4 237 162 3 3

6 273 198 4 4

8 345 270 4 4

12 399 324 6 6

16 453 378 7 7

11.5

92

654.5

3615

9.5

248

B

A

Technical Specification

No. of Ways 4, 6, 8, 12 & 16 Ways

Type of Installation Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 15 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240 Vac, 1 Phase

Incoming Options Up to 100 A Isolator (2P) or 100 A RCCB (2P)

Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2

Earthing Bar Terminal Capacity 25 mm2

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529t

Page 7: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

12 13

Perfection that Matters Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS

PER PHASE ISOLATION (PPI) VERTICAL - 4 TIER

Clean Earth Bar Provision

Stand-off foot form for stable installation

Earthing Screw

Neutral link per phase

RCCB 2P

Main Neutral

Outgoing MCB 1P

Main Incomer Isolator 4P

Earth Bar

11.5

87

4.5

7674

0

640

A

B

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM

ø 31 ø 31

2+4 311 186 4 4

2+6 340 222 6 6

2+8 378 258 6 6

2+12 448 330 8 8

PER PHASE ISOLATION (PPI) VERTICAL - 4 TIER

Technical Specification

No. of Ways 2+4, 2+6, 2+8 & 2+12 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Straight Busbar

Busbar Rating 125 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P) or 100 A RCCB (4P)

Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2

Earthing Bar Terminal Capacity 25 mm2

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 8: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

14 15

Perfection that Matters Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS

TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD

Increased width of board to 440 mmto maximize wiring space

Incomer 125A 4P/ 3P

Stepped Earth & Neutral bar assembly, to ease installation and improve access for testing

Terminal Shield covers for increased safety

Shrouding over Incomer

Combination screw headson all devices

Removable gland plates areprovided top/ bottom for

ease of installation

MCB 10 kA

Provision for mounting Clean Earth Kit

High quality - a clear sub circuit identification labels

Secondary cover slides over two location screws at bottom of board for easier fastening

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM SIDE

ø 31 ø 31 ø 38

4 430 248 8 6 1

6 484 329 8 6 1

8 538 410 8 6 1

12 700 572 8 6 1

440

11.5

126.

5

100

74B A

320

TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD

Technical Specification

No. of Ways 4, 8 & 12 Ways

Type of Installation Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Fish-bone Busbar

Busbar Rating 125 A

Busbar Short Time Withstand (Icw) 10 kA for 0.5 second

Busbar Conditional Short Circuit (Ics) 25 kA

Incoming Max. 125 A

Outgoing Max. Individual 63 A (SP & TP)

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options Up to 125 A Isolator (4P, 3P & 2P) or 100 A RCCB

Residual Current Protective Devices Options RCCB as Incomer / RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2, Split on both sides

Earthing Bar Terminal Capacity 25 mm2, Split on both sides

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 9: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

16 17

Perfection that Matters Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS POWER SERIES DISTRIBUTION BOARDS

TPN DOUBLE DOOR VERTICAL DISTRIBUTION BOARD SUITABLE FOR 80-125A MCB INCOMER

11.5

122.

3

954.

5

BA

440

320

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM SIDE

ø 38 ø 31 -

4 266 426 3 2 -

6 338 480 3 2 -

8 410 534 3 2 -

12 581 696 3 2 -

Technical Specification

No. of Ways 4, 8 & 12 Ways

Type of Installation Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Fish-bone Busbar

Busbar Rating 125 A

Busbar Short Time Withstand (Icw) 10 kA for 0.5 second

Busbar Conditional Short Circuit (Ics) 25 kA

Incoming Max. 125 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options MCB 125 A (3P or 3P+N)

Residual Current Protective Devices Options RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2, Split on both sides

Earthing Bar Terminal Capacity 25 mm2, Split on both sides

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

FP VERTICAL DOUBLE DOOR DISTRIBUTION BOARD SUITABLE FOR 160A MCCB INCOMER

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM SIDE

ø 31 ø 38 -

4 536 416 2 3 -

8 644 524 2 3 -

12 752 632 2 3 -

440

11.5

AB4.

5 91 118

340

Technical Specification

No. of Ways 4, 8 & 12 Ways

Type of Installation Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Fish-bone Busbar

Busbar Rating 160 A

Busbar Short Time Withstand (Icw) 10 kA for 0.5 second

Busbar Conditional Short Circuit (Ics) 25 kA

Incoming Max. 160 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options G Frame MCCB 160 A (3P or 3P+N)

Residual Current Protective Devices Options RCBO as Outgoing

Neutral Bar Terminal Capacity 25 mm2, Split on both sides

Earthing Bar Terminal Capacity 25 mm2, Split on both sides

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 10: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

18 19

Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS

Quality Features

Aesthetically superior Distribution Boards to suit the style of your interior décor.

3 Piece Concept for ease of maintenance - where instead of removing door assembly (Inner & Outer) only the intermediate plate needs to be removed for the purpose of maintenance, without spoiling the alignment & associated plastering / paint work.

Suitable for surface as well as flush mounting.

Ample knockouts in the top, bottom and sides for ease of wiring.

General Characteristics

Crabtree introduces the new XPRO series of aesthetically superior Distribution Boards with suitable Busbars for different ratings. Performance tested with a Conditional Short Circuit rating of 10 kA in SPN DB and TPN DB in accordance with IS 13032, BS EN 61439-3

Page 11: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

20 21

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

Classique - II Distribution Board - SPN Classique - II Distribution Board - SPN

Technical Specification

No. of Ways 4, 6, 8, 12 & 16 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240 Vac, 1 Phase

Incoming Options 100 A Isolator (2P) or 100 A RCCB (2P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (2P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 43

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM

SIDEø 25 ø 31 ø 25 ø 31

4 175 121 208 2 - 2 - 1

6 211 157 244 3 - 3 - 1

8 247 193 280 2 2 2 2 1

12 319 265 352 4 2 4 2 1

16 391 337 424 4 2 4 2 1

DIMENSIONS (in mm)

255

A

B 3

105

98

162

C

222

Page 12: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

22 23

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

Classique - II Distribution Board - TPN Classique - II Distribution Board - TPN

Technical Specification

No. of Ways 4, 6, 8 & 12 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P) ; 100A RCCB (4P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 43

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM SIDE

(EACH SIDE)ø 31 ø 31

4 323 235 356 4 4 2

6 323 235 356 6 6 2

8 395 307 428 6 6 2

DIMENSIONS (in mm)

428

295

B

A

310

9

116

C

400

Page 13: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

24 25

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

SP&N DISTRIBUTION BOARD SP&N DISTRIBUTION BOARD

Technical Specification

No. of Ways 4, 6, 8, 12 & 16 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240 Vac, 1 Phase

Incoming Options 100 A Isolator (2P) or 100 A RCCB (2P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (2P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 43

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

323323395534

235235307461

356356428566

428

295

B

A

310

9

116

C

400

Page 14: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

26 27

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

TP&N DISTRIBUTION BOARD

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM SIDE

ø 31 ø 31 ø 31

4 323 235 356 4 4 2

6 323 235 356 6 6 2

8 395 307 428 6 6 2

12 534 461 566 8 8 2

TP&N DISTRIBUTION BOARD

Technical Specification

No. of Ways 4, 6, 8 & 12 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P) ; 100A RCCB (4P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 43

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

2785 11

23B

A

C

428

295

DIMENSIONS (in mm)

Page 15: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

28 29

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

TP&N PPI DISTRIBUTION BOARD

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM SIDE

ø 31 ø 31 ø 31

4 323 268 356 4 4 2

6 395 329 428 6 6 2

8 534 479 567 8 8 2

TP&N PPI DISTRIBUTION BOARD

Technical Specification

No. of Ways 4, 6, & 8 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 100 A

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P)

Residual Current Protective Devices Options DP RCCB as Sub Incomer

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 43

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

2785

3BA

C

428

345

DIMENSIONS (in mm)

Page 16: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

30 31

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

8 SEGMENT DD DISTRIBUTION BOARD

Neutral Bar

Earth Bar

Sub Incomer RCCB (2P)

RCCB (4P)

Main Incomer Isolator (4P)

Outgoing MCB (1P)

Space for Changeover/Isolator

Outgoing MCB (1P)

102

91

625

659

485

A

C

B 3

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A B C TOPø 31

BOTTOMø 31

SIDEø 31

4 440 380 474 7 7 -

6 548 488 582 8 8 -

8 656 596 690 10 10 -

12 872 812 906 13 13 -

8 SEGMENT DD DISTRIBUTION BOARD

Technical Specification

No. of Ways 4, 6, 8 & 12 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 63 A per phase

Outgoing Max. Individual 63 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P) & 100 A RCCB (4P) or RCBO (4P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 60439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 17: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

32 33

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

CLASSIQUE PLUS AUTOMATIC PHASE SELECTOR DISTRIBUTION BOARD

AUTOMATIC PHASE SELECTOR (APS)

Automatic Phase Selector

Outgoing MCB 1P

Technical Specification

Reference Standard IEC 60947-6-1

No. of Poles 3P+N

Rated Current (In) 32 A

Rated Voltage (Ue) 415 Vac

Load Carrying Capacity / Per Phase 63A

Operating Voltage Range 200 to 415 Vac

Rated Frequency 50 Hz

Time Delay for Phase Changeover 3 second

Utilization Category AC31A

Indication Individual phase (R, Y, B), load, fault, type of fault (i.e. Undervoltage or Overvoltage)

Ambient Temperature -5° C to +55° C

Electrical Life 6000 operations

Rated Impulse Voltage (Uimp) 2.5 kV

Conditional Short Circuit Breaking Capacity 3 kA

Mounting DIN rail mounting

Terminal Capacity 10 mm2

Phase Priority Selection Manual (RYB, YBR, BRY)

Undervoltage Protection (L-N) 170 V (Factory Sealed)

Overvoltage Protection (L-N) 300 V (Factory Sealed)

Dimensions (L x W x H) in mm 87.5 x 71.8 x 63 mm

360

465

493

C

A

B

1010

3

100

3

No. of Ways

Rating

DIMENSIONS KNOCKOUT HOLES

A B CTOP BOTTOM

Ø31 Ø31

4 32A 473 394 505 6 6

6 32A 528 453 560 8 8

CLASSIQUE PLUS AUTOMATIC PHASE SELECTOR DISTRIBUTION BOARD

Technical Specification

No. of Ways 4 & 6 Ways

Type of Installation Flush / Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Advanced

Distribution Technique Straight Busbar

Busbar Rating 125 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 63 A

Outgoing Max. Individual 32 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 63 A Isolator or 63 A RCCB & 63 A MCB

Residual Current Protective Devices Options RCCB or RCBO as Incomer

Neutral Bar Terminal Capacity 25 mm2

Earthing Bar Terminal Capacity 25 mm2

Index of Protection (IP) IP 2X / IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 18: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

34 35

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

CLASSIQUE PLUS MANUAL PHASE SELECTOR HORIZONTAL DISTRIBUTION BOARD

11.5

135

435

360

108

4.5

A

B

No. of Ways

DIMENSIONS KNOCKOUT HOLES

A BTOP BOTTOM SIDE

ø 20 ø 25 ø 20 ø 25 ø 31

4 470 338 7 8 7 8 3

6 542 410 8 9 8 9 3

8 614 482 10 11 10 11 3

CLASSIQUE PLUS MANUAL PHASE SELECTOR HORIZONTAL DISTRIBUTION BOARD

Technical Specification

No. of Ways 4,6 & 8 Ways

Type of Installation Surface

Colour / Finish Bucket White Texture Finish

Door Options Flat Version

Door Locking Options Barrel Key Lock

Removable Gland Plates Top & Bottom

Protection Level of Distribution Boards Standard

Distribution Technique Straight Busbar

Busbar Rating 100 A

Busbar Short Time Withstand (Icw) 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics) 10 kA

Incoming Max. 63 A per phase

Outgoing Max. Individual 32 A

Voltage Rating 240-415 Vac, 3 Phase / 4 Wire

Incoming Options 100 A Isolator (4P) & R, Y, B Indicating Lights (3P+N) & 100 A RCCB (4P)

Residual Current Protective Devices Options RCCB or RCBO as Incomer (4P)

Neutral Bar Terminal Capacity 16 mm2

Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 42

Insulation Voltage (Ui) 690 Vac

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard IS/IEC 60529

DIMENSIONS (in mm)

Page 19: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

36 37

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

TIMER DISTRIBUTION BOARDKeeping the space constraint at the ATM sites, Havells has launched power solutions that will improve uptime and reduce operational costs of ATMs (Automated Teller Machine). It has a built-in energy saving timer based control for the ATM air conditioner and lights of the lobby and backroom. it is also suitable for controlling ACs, Pumps, Street Lights & Motors etc.

TIMER DISTRIBUTION BOARD

Technical Specification

Type of Installation Flush / Surface

Colour / Finish Bucket White

Door Options Flat Version

Incoming DP RCBO/RCCB/MCB

Outgoing MCB

Voltage Rating 240 Vac

Neutral & Earthing Bar Terminal Capacity 16 mm2

Index of Protection (IP) IP 42

Frequency 50 Hz

Ambient Temperature -5° C to 40° C

Distribution Board - Reference Standard IEC 61439 - 3

Index of Protection (IP) - Reference Standard IS/IEC 60529

Contactor TP 25A, 240 Vac

Timer 24 Hour Programmable Time Switch

WIRING DIAGRAMTimer Classique DB Power Wiring

WIRING DIAGRAM Timer Classique DB Control Wiring

115

312

344

465

493 36

013

2.2

DIMENSIONS (in mm)

Page 20: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

38 39

Perfection that Matters Perfection that Matters

CLASSIQUE DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

PLUG & SOCKET

RatingDimensions (in mm)

Knockout Holes (Ø25)

A B C D E Top Bottom

20A SP 152 116 167 139 124 2 2

20A DP 152 116 167 139 124 2 2

30A TP 278 230 293 129 114 1 1

MCB ENCLOSURE - SHEET STEEL

102

63

10C A

E

BD

No. of Ways

Dimensions (in mm)Knockout Holes

(Ø25)

A B C D E Top Bottom

DP 60 160 70 170 30 1 1

FP 98 180 108 190 62 2 2

MCB ENCLOSURE - PLASTIC

of the Electrical appliances.

142

110

A61B

No. of WaysDimensions (in mm)

A B

SP / DP 29.4 43.4

TP / FP 57 79

Page 21: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

40 41

Perfection that Matters

General Characteristics

Crabtree introduces the new XPRO range of MCBs rating from 0.5 A to 125 A. The range offers a variety of feature benefits such as Uniform Breaking Capacity of 10kA across entire range in accordance with IS/IEC 60898-1 & IS/IEC 60947-2, it also incorporates features like Inscription Window, Safety Terminal, Large Cable terminals, Bi stable Clip, Positive Contact Indication, Field fittable Auxiliary Contacts & Air Circulation (When two poles are placed adjacent to each other the channels between two poles form a tunnel resulting in very effective air circulation around individual poles)

MINIATURE CIRCUIT BREAKER

Quality Features

Inscription Window - Ensures circuit identification and hence reduces maintenance downtime

Safety Terminals - They guide the cable towards the cage terminal and avoid improper cable termination

Large Cable Terminals - The terminals are suitable for cables up to 35mm2 cross section area thus

making it suitable for copper and aluminium cables

Bi Stable Clip - Every device is provided with a dual position DIN rail clamp. Hence, a device can

be easily changed from a bank of devices connected by a busbar without disturbing your existing wiring

Positive Contact Indication - It clearly indicates contact position through Flag Indication (Red-ON, Green-OFF)

thus enhancing safety

Air Circulation - When two poles are placed adjacent to each other, the channels between two poles form

a tunnel resulting in very effective air circulation around individual poles

Field fittable Auxiliary Contacts

Page 22: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters Perfection that Matters

MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER

42 43

CIRCUIT BREAKER DEFINITION

A circuit breaker is an electro mechanical device designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. Unlike a fuse, which operates once and then has to be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation

CONSTRUCTIONMiniature Circuit Breakers have precisely formed moulded case & cover of flame retardant high strength thermoplastic material having high melting point, low water absorption, high dielectric strength and temperature capacity. The Switching Mechanism is independent, manual and trip free, i.e., the breaker trips internally even if the operating knob is held in ON position.

The Contact Mechanism comprises of fixed & moving contacts specially designed for reliability, long life and anti-weld properties.The Arc Extinguishing Device comprises of 13 plates arc chute. The arc under the influence of the magnetic field and arc guide is moved into the arc chute where it is rapidly split and quenched. The tripping mechanism is Thermal Magnetic Type.

THERMAL OPERATIONThe thermal operation provides protection from moderate overloads. Under overload condition, a thermometallic element (bimetallic strip) deflects until it operates a latching mechanism allowing the main contacts to open.

MAGNETIC OPERATIONIn magnetic operation, large overloads or short circuit current actuates a solenoid causing a plunger to strike the latching mechanism rapidly opening the main contacts.

INTERNAL VIEW

Dual Outgoing Terminal

Bimetal Strip

Knob

Magnetic Coil

Positive ContactIndication

Fix Contact

Moving Contact

Dual Incoming Terminal

Arc Runner

Arc Chutes

Back paper

Calibration Screw

Bimetal Carrier

Safety Terminal

Technical Specification

Reference Standard IS/IEC 60898-1 ; IS/IEC 60947-2

Type / Series C & D Curve

No. of Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P

Rated Current (In) 0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Short Circuit Breaking Capacity10 kA - C Curve 10 kA - D Curve, 32A 4.5 kA - D Curve, > 32A

Magnetic Release Setting(5-10)In - C Curve(10-20)In - D Curve

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 4000

Operating Temperature -5° C to +55° C

Humidity 95% RH

Energy Limit Class 3

Terminal Capacity (max) 35 mm2

Tightening Torque 2 N-m

Vibration 3 g

Shock Resistance 40 mm free fall

Protection Class IP20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight / Pole in kg 0.125 kg

Dimensions (H x D x W) / Pole in mm 87.5 x 62 x 17.7 mm

Mounting Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame-retardant thermoplastic material

Busbar Connections Top Side Pin Type

Busbar Connections Bottom Side Pin / Fork Type

Auxiliary Contacts Yes

Shunt Trip Yes

53.1 70.817.7

5.3

35.4 50.8

92.8

4462

71.7

4587.5

6.8

42

LEN

GTH

STR

IP

LEN

GTH

STR

IP

MINIATURE CIRCUIT BREAKER DIMENSIONS (in mm)

Page 23: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters Perfection that Matters

MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER

44 45

CHARACTERISTICS CURVES

TRIPPING CHARACTERISTICS

Based on the Tripping Characteristics, MCBs are available in ‘C’ and ‘D’ curve to suit different types of applications.

‘C’ Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits). Short circuit release is set to (5 - 10) In

‘D’ Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In

THERMAL TRIPPING

The Tripping is initiated by a bimetal strip in case of overload. The standard defines the range of tripping for specific overload values. Reference ambient temperature is 30°C.

MAGNETIC TRIPPING

An electromagnet with plunger ensures instantaneous tripping in the event of short-circuit.

Based on the Tripping Characteristics, MCBs are available in ‘C’ and ‘D’ curve to suit different types of applications.

‘C’ Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits). Short circuit release is set to (5 - 10) In

‘D’ Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In

As per

Thermal Tripping Magnetic Tripping

No tripping

Tripping Time Hold Trip Time

IS / IEC 60898-1

Current Current Limits Current Current Limits

I1 I2 t I4 I5 t

C Curve1.13 x In >1h 5xIn >0.1s

1.45 x In <1h 10 x In <0.1s

D Curve1.13 x In >1h 10xIn >0.1s

1.45 x In <1h 20 x In <0.1s

l3 = 2.55 x lN1 s < t < 60s for ln (In 32A)

1 s < t < 120s for ln (In 32A)

CHARACTERISTICS ACCORDING TO IS/IEC 60898-1

Miniature Circuit Breakers (MCB) are intended for the protection of wiring installations against both overloads and short-circuits in domestic or commercial wiring installations where operation is possible by uninstructed people

CURRENT LIMITING DESIGN

In a current limiting breaker, the tripping & arc control mechanism are so designed that under short circuit conditions, the contacts are physically separated and the electrodynamic forces set up by fault current, assist the extinction in less than half cycle.

The figure shows the current limiting effect of circuit breakers.

Fault Traces for Voltage & Current

0 = Point of fault initiation

tx = Contact opening time (i.e., creation of arc)

t1 = Current / Voltage peak (i.e., current limitation)

t2 = Time to total extinction of arc (i.e., complete shutdown of fault current)

HAMMER TRIP MECHANISM

Current Limiting design in itself may not fulfill the requirement of quick breaking (instantaneous action) mainly due to inertia of the Latch mechanism and interconnected sequence of operations.

A Hammer directly connected to the plunger strikes the moving contact arm with a force proportional to the peak current there by forcibly separating the moving contact from the fixed contact much before the latch mechanism operates. This further reduces the opening time of the circuit breaker.

Plunger

Hammer

Page 24: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters Perfection that Matters

MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER

46 47

Calculation In / switch = K1 x K2 x In

Example 4 MCBs with In = 10A, and the amb. temp. is 50°C kept with no gap in between

Solution K1 =0.89 (from graph 1)

K2 =0.78 (from graph 2)

In / pole = 0.89 x 0.78 x 10 = 6.94 A

thus from this we know that if we use more than 2 MCB together, their rating gets effected

Diversity Factor(K2 Factor)

Graph 2

K2

Maximum Permissible Rated Current(K1 Factor)

K1

Graph 1

AMBIENT TEMPERATURE COMPENSATION / DIVERSITY FACTOR CHART

EFFECT OF FREQUENCY VARIATION

MCBs are designed to operate at AC frequency 50 / 60 Hz. However, MCBs specially suitable for DC applications and for frequencies upto 400Hz can be supplied on request.

These can be used on different frequencies in supply from 16 2/3 - 60 Hz without any deration.

For higher frequencies, normal MCBs can be used with a multiplication factor which shall only affect its magnetic trip current.

Supply AC DC

Frequency 100Hz 200Hz 400Hz

MultiplicationFactor

1.1 1.2 1.5 1.5

let through energy i2t

MCB Current Rating (A) Backup Fuse Rating (A)

1 25

2 35

4 50

6 80

10-63 100

COLD RESISTANCE & POWER LOSS DETAILSTHE POWER LOSS VALUE DECLARED ARE AT RATED CURRENT.

Remarks:- Tolerance ±5%

Rated CurrentIn (A)

Cold ResistanceRI (m )

Power Loss Per Pole (Watt)

0.5 3467 1.3

1 1178 1.3

2 281 1.5

3 156 2.1

4 92 2.2

6 16.55 0.7

10 11.68 1.4

13 10.1 1.7

16 8 2.2

20 5.25 2.5

25 3.78 3.1

32 2.57 3.4

40 1.94 3.9

63 1.4 7.3

MAXIMUM BACKUP PROTECTION

At site, no. of MCBs are used for outgoing connection. To protect the MCBs under short circuit (higher capacity), we need to put fuses in the incoming side. The current rating of fuses should not be more than the values given in the table.

The power loss of circuit breakers is closely controlled by the Standards and is calculated on the basis of the voltage drop across the main terminals measured at the rated current. The power loss of Crabtree circuit breakers is much lower than that required by the IS/IEC Standard, giving the benefit of cooler running and reduced heating effects when mounted in groups.

Page 25: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters Perfection that Matters

MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKER

48 49

MCB SELECTION CHARTFOR HOUSE HOLD APPLICATIONS

Appliances Capacity / watt (Load) (240V~ 1ph) Current Rating of MCB Type of MCB

Air Conditioner

1.0 tonnes 10A* “C” series

1.5 tonnes 16A* “C” series

2.0 tonnes 20A* “C” series

Refrigerator165 litres 3A* “C” series

350 litres 4A* “C” series

Oven cum Griller4500W 32A “C” series

1750W 10A “C” series

Oven onlyHot Plate onlyRoom Heater

750W 6A “C” series

2000W 10A “C” series

1000W 6A “C” series

2000W 10A “C” series

Washing Machine 300W 2A “C” series

Washing Machine (with heater) 1300W 8A “C” series

SELECTION OF MCB FOR MOTOR PROTECTION

Incomer Current Rating, For Three Phase :

S. No. kW HP

1 Phase 230V DOL Starting

3 Phase 400V DOL Starting

3 Phase 400V Assisted Starting Star Delta

Full Load Current

MCB Selection

Full Load Current

MCB Selection

Full Load Current

MCB Selection

1 0.18 0.24 2.8 10 0.9 2 — — —

2 0.25 0.34 3.2 10 1.2 2 — — —

3 0.37 0.50 3.5 10 1.2 2 — — —

4 0.55 0.74 4.8 16 1.8 3 — — —

5 0.75 1.01 6.2 20 2.0 3 — — —

6 1.1 1.47 8.7 25 2.6 6 — — —

7 1.5 2.01 11.8 32 3.5 10 — — —

8 2.2 2.95 17.5 50 4.4 10 — — —

9 3 4.02 20.0 63 6.3 16 6.3 16 10

10 3.75 5.03 24.0 80 8.2 20 8.2 20 10

11 5.5 7.37 26.0 80 11.2 25 11.2 32 16

12 7.5 10.05 47.0 125 14.4 40 14.4 40 25

13 10 13.40 — — 21.0 50 21.0 50 32

14 15 20.11 — — 27.0 100 27.0 63 40

15 18.5 24.80 — — 32.0 125 32.0 — 50

16 22 29.49 — — 38.0 125 38.0 — 63

17 30 40.21 — — 51.0 125 51.0 — 63

Total Load in Watts

Total Load in Watts

240V

3X415V

Calculation Formulae :

Incomer Current Rating, For Single Phase :Note : One lighting circuit can have upto 800W or upto 10 lighting points

One power circuit can have upto 2000W or 1 power points

* It may vary from manufacturer to manufacturer. Please check before installation.

MCB Downstream

MCB Upstream ‘C’ Curve

‘C’ Curve 10A 16A 20A 25A 32A 40A 50A 63A

0.5 to 5A 50 80 100 125 160 200 250 315

6A 80 100 125 160 200 250 315

10A 100 125 160 200 250 315

16A 160 200 250 315

20A 200 250 315

25A 250 315

32A 315

40A

50A

DISCRIMINATION DATA

MCB Downstream

HRC Fuse Link Upstream

‘C’ Curve 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A

0.5 to 6A 700 850 960 1200 1350 1750 2800 4500 5200 6000

10A 700 960 1200 1350 1750 2800 4500 5200 6000

13A 850 1200 1200 1750 2800 4500 5200 6000

16A 960 1100 1500 2500 3200 5200 6000

20A 1100 1500 2500 3200 4500 5200

25A 960 1350 2000 3200 4500 5200

32A 1200 1750 2800 4500 5200

40A 1750 2800 4500 5200

50A 2500 3200 4500

63A 3200 4500

DISCRIMINATION WITH FUSES

HRC Fuse Upstream Type gG

MCB Downstream

MCCB Upstream

‘C’ Curve 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200 250A 320A 400A 500A 630A 800A 1000A 1250A 1600A

0.5 to 6A 1100 1200 1400 1700 2000 2500 3400 4800 5800 6700 T T T T T T T T T T T

10A - 1100 1200 1400 1700 2100 2500 3000 3500 4300 T T T T T T T T T T T

16A - - - 1300 1600 1900 2100 2400 2700 3200 8300 T T T T T T T T T T

20A - - - - 1600 1900 2100 2400 2700 2500 8300 T T T T T T T T T T

25A - - - - - 1700 1800 2000 2200 2500 5400 8700 T T T T T T T T T

32A - - - - - - 1800 2000 2200 2500 5400 8700 T T T T T T T T T

40A - - - - - - - 1500 1700 2000 4300 7000 T T T T T T T T T

50A - - - - - - - - 1300 1500 3600 5900 9000 T T T T T T T T

63A - - - - - - - - - 1100 2800 5200 8200 T T T T T T T T

Prospective Fault Levels to which selectivity is achieved ( T = Total Selectivity )

Page 26: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

MINIATURE CIRCUIT BREAKER

5150

Perfection that Matters

MINIATURE CIRCUIT BREAKER (80A-125A)

Electrical Distribution needs are continuously evolving in residential, commercial and industrial sectors. Improved operational safety, continuity of service, greater convenience and operating cost have assumed a tremendous significance. Crabtree Miniature Circuit Breakers have been designed to continuously adopt to these changing needs.

Technical Specification

Reference Standard IS/IEC 60947-2 ; IS/IEC 60898-1

Type / Series C curve

No. of Poles 1P, 2P, 3P, 4P

Rated Current (In) 80A, 100A, 125 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Ultimate Short Circuit Breaking Capacity (Icu) 10 kA

Rated Service Short Circuit Breaking Capacity (Ics) 75% of Icu

Magnetic Release Setting (5-10)In

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 4000

Operating Temperature -5° C to +55° C

Humidity 95% RH

Energy Limit Class 3

Terminal Capacity (max) 50 mm2

Tightening Torque 3.5 N-m

Vibration 3 g

Shock Resistance 40 mm free fall

Protection Class IP 20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight / Pole in kg 0.150 kg

Dimensions (H x D x W) / Pole in mm 81 x 64.3 x 26.5 mm

Mounting Clip on DIN Rail (35mm x 7.5mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material

Busbar Connections Top Side Pin Type

Busbar Connections Bottom Side Pin Type

MINIATURE CIRCUIT BREAKER (80A-125A)

MINIATURE CIRCUIT BREAKER

DIMENSIONS (in mm)

Page 27: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

MINIATURE CIRCUIT BREAKER

5352

Perfection that Matters

Attachment used for Signalling, Indication, Annunciation and Interlocking

Technical Specification

Standard Conformity IS/IEC 60947-1

Current Carrying Capacity (Max) 6 A

Rated Voltage (Ue) 240 Vac

Contact Configuration 1 NO + 1 NC

Utilization Category AC 11

Electrical Endurance (No. of operations) 10000

Terminal Capacity (Max) 6 mm2

Protection Class IP 20 as per IS/IEC 60529

Mounting Left side of MCB (Field Fittable)

8.85 8.85

11.36.8

16.516.5

S-TYPE AUX

H-TYPE AUX

62.0

44.0

69.8

1.4

87.5

45.0

2.4

11.3

MCB AUXILIARY CONTACT DIMENSIONS (in mm)

ACCESSORIES

AUXILIARY CONTACT

MINIATURE CIRCUIT BREAKER

1. To trip the Circuit Breaker through Shunt Trip Coil, 70% to 110% of the rated voltage is to be applied across D1 & D2

2. The Shunt Trip coil is short time rated and it trips the breaker instantaneously (i.e. continuous duty not required)

Attachment used for remote tripping

Technical Specification

Standard Conformity IS/IEC 60947-3

Coil Consumption 6 VA

Rated Voltage (ac) (Ue) 240 V

(dc) (Ue) 48, 24, 12 V

Rated Frequency 50 Hz

Operating Voltage Range 70% to 110% of rated voltage

Electrical Endurance (No. of ops) 10000

Terminal Capacity (Max) 25 mm2

Protection Class IP 20 as per IEC 60529/IS-2147

Mounting Right side of MCB

(Factory assembled)

35.4 50.8

92.8

44

62

71.7

4587.5

6.8

42

LENGTH

STRIPLENGTH

STRIP

MCB SHUNT TRIP DIMENSIONS (in mm)

SHUNT TRIP

Page 28: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

ISOLATORS

5554

Perfection that Matters

ISOLATOR

Inscription Window Safety Terminal Positive Contact Indication Bi-stable Clipdication Bi-stable Clip

Technical Specification

Reference Standard IS/IEC 60947-3

No. of Poles 1P, 2P, 3P, 4P

Utilization Category AC 22A

Rated Current (In) 40, 63 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 10000

Operating Temperature -5° C to +55° C

Humidity 95% RH

Terminal Capacity (max) 35 mm2 (up to 63A)

Tightening Torque 2 N-m

Vibration 3 g

Shock Resistance 40mm free fall

Protection Class IP 20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight / Pole in kg 0.090 kg

Dimensions (H x D x W) / Pole in mm 87.5 x 62 x 17.7 mm

Mounting Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material

Busbar Connections Top Side Pin Type

Busbar Connections Bottom Side Pin / Fork Type

53.1 70.817.7

5.3

35.4 50.8

92.8

4462

71.7

4587.5

6.8

42

LEN

GTH

STR

IP

LEN

GTH

STR

IP

ISOLATOR DIMENSIONS (in mm)

Page 29: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

5756

Perfection that Matters

ISOLATOR (80A-125A) Technical Specification

Reference Standard IS/IEC 60947-3

No. of Poles 2P, 3P, 4P

Utilization Category AC 22A

Rated Current (In) 80, 100, 125 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 10000

Operating Temperature -5° C to +55° C

Humidity 95% RH

Terminal Capacity (max) 50 mm2

Tightening Torque 2.5 N-m

Vibration g 3 g

Shock Resistance 40 mm free fall

Protection Class IP 20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight in kg 0.158 kg (for 2P), 0.237 kg (for 3P), 0.316 kg (for 4P)

Dimensions (H x D x W) in mm87.5 x 62 x 35.4 mm (for 2P), 87.5 x 62 x 53.1 mm (for 3P),87.5 x 62 x 70.8 mm (for 4P)

Mounting Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material

Busbar Connections Top Side Pin / Fork Type

Busbar Connections Bottom Side Pin / Fork Type

DIMENSIONS (in mm)

35.4

5.3

92.8 4587

.5

44

6.8

50.8

62

73.4

42

53.1 70.8

DIMENSIONS (in mm)

Perfection that Matters

Technical Information

Standard Conformity IS/IEC 60947-5 -1

Contacts

Rated Operation Voltage 240 Vac

Rating Electrical Power 1.2 Watt

Rated Frequency 50 Hz

Terminal Capacity 2.5 mm2

Light Indicaton

Colour

Light Permanent

Source Neon Lamp

Mounting on Din Rail 35 mm x 7.5 mm

Protection Class IP 20

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material.

Ambient Temperature -5 °C to 55 °C

Terminal Capacity: 2.5 mm2

Rated Electrical Power: 3 piece 0.2 W each

Source: LED

INDICATOR LIGHT

8.85 8.85

6.8 63.0

44.0

84.0 35

.5

45.0

64.5

Page 30: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

58 59

Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER

Quality Features

Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually

Inscription Window - Ensures circuit identification and hence reduces maintenance downtime

Safety Terminals - They guide the cable towards the cage terminal and avoid improper cable termination

Dual Termination - Two types of busbars can be used, that is, Fork Type and Pin Type

Large Cable Terminals - The terminals are suitable for cables up to 35mm2 cross section area.

Thus making it suitable for copper and aluminium cables

Bi Stable Clip - Every device is provided with a dual position DIN rail clamp. Hence, a device can

be easily changed from a bank of devices connected by a busbar without disturbing your existing wiring

Positive Contact Indication - It clearly indicates contact position through Flag Indication

(Red-ON, Green-OFF) thus enhancing safety

Field fittable Auxiliary Contacts (up to 63 A)

Advance Neutral - where neutral makes ahead of phases and breaks after phases, which ensures

complete discharge of line inductance and capacitance, hence making it suitable as main switch

Test button for regular inspection/testing

General Characteristics

Crabtree introduces the new XPRO range of RCCBs rating from 16 A to 100 A. The range offers a variety of feature benefits such as Conditional Short Circuit Breaking Capacity of 10 kA across the entire range of RCCBs in accordance with IS 12640-1 & IEC 61008, it also incorporates features like Mid Trip - Different knob position to indicate whether the device is switched OFF by a fault or switched OFF manually, Inscription Window, Safety Terminals, Dual Termination, Large Cable Terminals, Bi Stable Clip, Positive Contact Indication, Field fittable Auxiliary Contacts, Test Button for Regular Inspection.

Page 31: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

60 61

Perfection that Matters Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

RESIDUAL CURRENT CIRCUIT BREAKER

Technical Specification

Reference Standard IS 12640-1 ; IEC 61008

No. of Poles 2P, 4P

Rated Current (In) 16, 25, 32, 40, 63 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Conditional Short Circuit Current (Inc) 10 kA

Rated Residual Operating Current (I n) 30, 100 & 300 mA

Rated Making Breaking Capacity (Im) 500 A or 10In whichever is greater

Operating Characteristics in presence of Residual Current with d.c. components

‘A’ Type & ‘AC’ Type

Trip Time 1I n < 300ms, 5I n < 40ms

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000

Operating Temperature -25° C to + 55° C

Humidity 95% RH

Terminal Capacity (max) 35 mm2

Tightening Torque 2 N-m

Vibration 3 g

Shock Resistance 40mm free fall

Protection Class IP 20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight in kg 0.215 kg (for 2P) ; 0.335 kg (for 4P)

Dimensions (H x D x W) 87.5 x 62 x 35.9 mm (for 2P) ; 87.5 x 62 x 71.8 mm (for 4P)

Mounting Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material

Busbar Connections Top Side Pin / Fork Type

Busbar Connections Bottom Side Pin / Fork Type

Auxiliary Contacts Yes

PROTECTION

AGAINST ELECTRICAL SHOCK

The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions such as:

1. Breathing 2. Heartbeat

A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results:

500 mA Immediate cardiac arrest resulting in death

70-100 mA Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate. This situation is dangerous since it is irreversible

20-30 mA Muscle contraction can cause respiratory paralysis

10 mA Muscle contraction : the person remains “stuck” to the conductor

1-10 mA Prickling sensations

However, electrical shock should not be viewed in terms of “current” alone, but in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.

The human body has known limits:

Maximum Earth Fault Loop Impedances

Rated res. op. current I n- 5° C25 V

- 5° C50 V

0.03 A 830 1660 0.10 A 250 500 0.30 A 83 166 0.50 A 50 100

AGAINST INDIRECT CONTACT

Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50.

Example

For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666

Page 32: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

62 63

Perfection that Matters Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

RCCB Protection at Indirect Contact

Fault resistance

earthing resistance

actual contact voltage

residual (fault) current

rated residual operating current

permissible contact voltage

WORKING PRINCIPLE

Residual current circuit breaker (abbr. RCCB) continuously establish the total of the momentary values of all currents flowing via the active conductors to an electrical installations operated by an earthed AC mains supply. According to Kirchhoff’s first law, this total must always be zero. In the event of a short-to-earth due to defective insulation, such currents will not total zero, because – depending upon the fault resistance RF and the ground circuit resistance RA – a residual current, also called fault current, will not flow via the active conductors but return via the earth to the power supply. If the r.m.s. value of the residual current exceeds the rated residual operating current in the RCCB, then the latter will trigger the disconnection of the installation from the power supply.

AGAINST FIRE

The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp.

The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting.

ACTUATION TIME CHARACTERISTICS

Residual Current Multiple of I n (mA)

I n (mA)

Tim

e (in

ms)

500

300

150

40

0.50 1 2 5 10 20 50

Response time of a non-delayed RCCB as a function of the magnitude of residual current.

RCCB Protection at Direct Contact

L1L2L3N

RCD

Resistance of thehuman body

Resistance at site

Operations earth

R St

RM

RESET FUNCTION

The switch mechanism of RCCBs in XPRO range provides a reset function. The position of the switch lever indicates whether the RCCB has been switched off manually (position O) or as the result of a fault (central position). In order to cancel the central positioning the switch needs first to be moved to position ‘O’, only then can the RCCB be switched on again.

ON POSITION MID POSITION OFF POSITION

ON

RESET

OFF

The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.

WIRING DIAGRAM

Line

Load Load Load

LineLine

Page 33: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

64 65

Perfection that Matters Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER RESIDUAL CURRENT CIRCUIT BREAKER

Zone Physiological Effects

Zone 1

Usually no reactions

Zone 2

Usually no harmful physiological effects

Zone 3

Usually no organic damage to be expected. Likelihood of muscular contraction and difficulty in breathing, reversible disturbances of formation and conduction of impulse in the heart and transient cardiac arrest without cardiac fibrillation increases with current magnitude and time.

Zone 4

In addition to the effects of Zone 3, probability if cardiac fibrillation increased upto 5% (curve C2) upto 50% (curve C3) and above 50% beyond curve C3. It increases with magnitude and time, and pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur.

To be within zone of the IEC curve as shown below. It is necessary for the ELCB to operate within 50ms at 240 mA and 150ms at 80mA. Both these conditions are satisfied by 30mA ELCB.

For households, individual outlets, wet areas and temporary installations, ELCB with sensitivity not exceeding 30mA is advisable.

100 mA

A 100mA ELCB will normally give high degree of protection against electrocution but there is a possibility that the shock current could fall below the tripping level of ELCB. This could occur if additional resistances to that of human body are included in the earth path.

The 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance upto 500 Ohms.

300 / 500mA

A 300/500 mA ELCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small. 300/500mA ELCB will not give any protection against electrocution.

SELECTION

30 mA

A 30 mA ELCB will provide a high degree of protection against electrocution in an accidental shock hazard situation. The current flowing through human body could be between 80mA and 240mA depending on the resistance of the human body and the voltage across it.

RCCB - STANDARD APPLICATIONS

at 50 / 60 Hz

currents are not sinusoidal. They are particularly suitable for the following specific applications (dedicated lines) or circuits that may produce DC fault currents, eg variable speed drives with frequency inverters, etc.

DIMENSIONS (in mm)

DIMENSIONS (in mm)

ACCESSORIES

Attachment used for Signalling, Indication, Annunciation and Interlocking.

Technical SpecificationStandard Conformity IS/IEC 60947-1

Current Carrying Capacity (Max) 6 A

Rated Voltage (Ue) 240 Vac

Contact Configuration 1 NO + 1 NC

Utilization Category AC 11

Electrical Endurance (No. of operations) 10000

Terminal Capacity (Max) 6 mm2

Protection Class IP 20 as per IEC-60529/IS-2147

Mounting Left side of RCCB (Field Fittable)

8.85 8.85

11.36.8

16.516.5

S-TYPE AUX

H-TYPE AUX

62.0

44.0

69.8

1.4

87.5

45.0

2.4

11.3

Contact Configuration Current

1NO + 1NC 6 A

Auxiliary Contact

71.8

5.3

92.8 87

.5

42

45

44

50.8

6.8

62

71.7

35.9

STR

IP

LEN

GTH

STR

IP

LEN

GTH

Page 34: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

67

Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER

66

Perfection that Matters

Technical Specification

Reference Standard IS 12640-1 ; IEC 61008

No. of Poles 2P, 4P

Rated Current (In) 80, 100 A

Rated Voltage (Ue) 240/415 Vac

Rated Frequency (f) 50 Hz

Rated Conditional Short Circuit Current (Inc) 10 kA

Rated Residual Operating Current (I n) 30, 100 & 300 mA

Rated Making Breaking Capacity (Im) 10In

Operating Characteristics in presence of Residual Current with d.c. components

‘A’ Type & ‘AC’ Type

Trip Time 1I n < 300ms, 5I n < 40ms

Rated Insulation Voltage (Ui) 690 V

Rated Impulse Voltage (Uimp) 4 kV

Dielectric Strength 2.5 kV

Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000

Operating Temperature -25° C to + 55° C

Humidity 95% RH

Terminal Capacity (max) 50 mm2

Tightening Torque 2.5 N-m

Vibration 3 g

Shock Resistance 40mm free fall

Protection Class IP 20

Positive Contact Indication Yes, Through Flag Indication (Red-ON, Green-OFF)

Net Weight in kg 0.230 kg (for 2P) ; 0.404 kg (for 4P)

Dimensions (H x D x W) in mm 88.2 x 62 x 35.9 mm (for 2P) ; 88.2 x 62 x 71.8 mm (for 4P)

Mounting Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal

Case & Cover Moulded, flame retardant thermoplastic material

Busbar Connections Top Side Pin / Fork Type

Busbar Connections Bottom Side Pin / Fork Type

Auxiliary Contacts No

RESIDUAL CURRENT CIRCUIT BREAKER (80A-100A)

The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link

from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.

WIRING DIAGRAM

Line

Load Load Load

LineLine

72.0 36.0 62.0

44.0

6.8

36.0

71.7

45.0

88.2

5

88.2

5

STR

IP

LEN

GTH

DIMENSIONS (in mm)

Page 35: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

69

Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD

AND SHORT CIRCUIT PROTECTION (RCBO)

68

Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD AND SHORT CIRCUIT PROTECTION

CONSTRUCTION

RCBO is a single composite device which provides protection against over currents and earth leakage faults, it comes in the same width and profile as that of a standard MCB. It is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring high degree of protection to the user for a particular circuit. In normal use, it is safe to use and poses no threat to user as well as to environment.

FEATURES

2 for cool running while in operation.

The Functional Earth (FE) white color wire connected to earth provides this protection.

using electronic circuit is set to very precise values and thereby provide greater immunity to nuisance tripping that can be caused by mains borne noise, surge voltages, lighting surges, reactive loads, mains filters, etc.

the trip level to increase. In the case of a N - E fault, the user may have no way of knowing that this fault exists and that the RCBO has been desensitised. Under this condition, the Crabtree VD RCBO provides a far greater level of protection than a normal VI (Voltage Independent) RCBO.

AESTHETICS & CONVENIENCE

2 Module RCBO can simply replace existing MCB 2 pole when upgrading a board.

RELIABILITY & CONTINUITY OF SERVICE

ENERGY LIMITING

Crabtree RCBO meets the requirements for energy let through by IEC & British Standard for energy limiting class 3.

‘A’ TYPE RCBOs

Any electrical appliance with power control has the ability to produce earth fault currents with pulsating DC (rectified AC) components. RCBOs that provide this type of protection are referred to as ‘A’ Type RCBOs.

Standard VI (Voltage Independent) RCBOs do not provide this protection, and are referred to as ‘AC’ Type RCBOs. Crabtree VD RCBOs have been specifically designed to provide protection against pulsating DC fault currents.

Technical Information RCBO (1M) RCBO (2M) RCBO (4M)

Reference Standard IS 12640-2 ; IEC 61009 IS 12640-2 ; IEC 61009 IS 12640-2 ; IEC 61009Type / Series C Curve C Curve C Curve

No. of Poles 1P + Solid Neutral 1P + Switched Neutral (2M) 3P + Switched Neutral (4M)

Rated Current (In)6, 10, 16, 20, 25, 32, 40, 50 A

6, 10, 16, 20, 25, 32, 40 A 6, 10, 16, 20, 25, 32, 40 A

Rated Voltage (Ue) 240 Vac 240 Vac 415 VacRated Frequency (f) 50 Hz 50 Hz 50 HzRated Short Circuit Breaking Capacity 10 kA 10 kA 10 kARated Residual Operating Current (I n) 30 mA 30 mA, 100 mA, 300 mA 30 mA, 100 mA, 300 mARated Making Breaking Capacity (Im) 500 A 500 A 500 A Operating Characteristics in presence of Residual Current with d.c. components

‘A' Type ‘A' Type ‘A' Type

Magnetic Release Setting (5-10)In (5-10)In (5-10)InTrip Time < 40 ms < 40 ms < 40 msRated Insulation Voltage (Ui) 690 V 690 V 690 VRated Impulse Voltage (Uimp) 4 kV 4 kV 4 kVDielectric Strength 2.5 kV 2.5 kV 2.5 kVElectrical / Mechanical Endurance (no. of operations)

2000 / 3000 2000 / 3000 2000 / 3000

Operating Temperature -25° C to + 55° C -25° C to + 55° C -25° C to + 55° CHumidity 95% RH 95% RH 95% RH

Energy Limit Class 3 3 3Terminal Capacity (max) 25 mm2 35 mm2 35 mm2

Tightening Torque 2 N-m 2 N-m 2 N-mVibration 3 g 3 g 3 gShock Resistance 40mm free fall 40mm free fall 40mm free fallProtection Class IP 20 IP 20 IP 20Net Weight in kg 0.200 kg 0.420 kg 0.840 kgDimensions (H x D x W) / Pole 125 x 69.2 x 17.7 mm 87.5 x 68.4 x 35.4 mm 125 x 68.4 x 70.8 mm

MountingClip on DIN Rail (35 mm x 7.5 mm)

Clip on DIN Rail (35 mm x 7.5 mm)

Clip on DIN Rail (35 mm x 7.5 mm)

Installation Position Vertical / Horizontal Vertical / Horizontal Vertical / Horizontal

Case & CoverMoulded, flame retardant thermoplastic material

Moulded, flame retardant thermoplastic material

Moulded, flame retardant thermoplastic material

Busbar Connections Top Side - Pin Type Pin TypeBusbar Connections Bottom Side Pin / Fork Type Pin / Fork Type Pin / Fork TypeN-Flying Lead Length 700 mm - -

Page 36: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

70 71

Perfection that Matters Perfection that Matters

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD

AND SHORT CIRCUIT PROTECTION (RCBO)

RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERLOAD

AND SHORT CIRCUIT PROTECTION (RCBO)

Load Terminal (Phase)

Incoming N-Flying Lead

Load Terminal (Neutral)

FE (Functional Earth) Connection

Test Button

Line Terminal (Phase)

INSTALLATION INSTRUCTIONS FOR 1M RCBO

Monthly Functional Test: Push Test Button, RCBO must trip

Figure 1

Time Current Characteristics C Curve

0.01

0.10

1.00

10.00

100.00

1000.00

10000.00

001011

Multiples of Rated Current

Tim

e (s

ec)

Residual Current Tripping Characteristics

0.01

0.10

1.00

10.00

100.00

1000.00

0.001 0.01 0.1 1 10 100 1000 10000

Rated Residual Current in Amperes

Tim

e (s

ec)

.03

.015

0.015

0.04

TRIPPING CHARACTERISTICS

44

125

44

42

45

6.817.7

69.2

O-OFF

IN

IN

OUT OUTNN L

L

T

FE

Circuit Diagram for 1M RCBO

RCBO (1M)

RCBO (2M) RCBO (4M)

DIMENSIONS (in mm)

Page 37: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

THREE PHASE AUTOMATIC CHANGEOVER WITH CURRENT LIMITER (TPN ACCL)

7372

Perfection that Matters

TPN ACCL

The Power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the Residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.

TPN ACCL is a fully automatic high precision microcontroller based device and is ideally suited for proper/efficient utilization of standby generator used in multi-storied apartments, commercial complexes, etc.

Functions-When the Mains Supply is available: Automatic mode: The TPN ACCL allows full load current on each phase when all the 3 phases of mains supply is available, and when any one of the phase fails,

TPN ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply. Manual mode: If R phase is available, it will continue to run the load on main supply irrespective of the availability of other phases. But if R phase fails, the TPN

ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply. Note: It is recommended to connect all essential load to R phase.

- When the Mains supply fails: With AGS (automatic generator start feature): TPN ACCL provides signalling through a potential free contact for starting the Generator.

Without AGS (automatic generator start feature):a. When the mains supply goes OFF, a consumer is automatically connected to the generator in case generator supply is available, after a time

delay of 8-12 seconds in order to limit the sudden load on the generator.

b. The TPN ACCL has a current limiting feature on the generator side. If the load exceeds the allowable limit, TPN ACCL will give a pre-trip indication and after a delay of 5 second, TPN ACCL will trip and goes on hold. After a predetermined time delay (say 8 sec), it will again check the connected load and gives the supply if the load is under the allowable limit. During this period, the consumer is expected to switch off the non-essential loads and reduce it within the limit. The overloaded phase will be indicated through LED.

c. In an unlikely event, if the consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load is automatically disconnected after 5 cycles of interruption.

d. The supply from mains to the load can be restored only after pressing the Reset button present in the front of TPN ACCL.

When Mains supply is restored

a. As soon as the main supply restores, the load is automatically transferred to the mains supply after a delay of 2-4 sec.b. With AGS, TPN ACCL itself generates the signal to automatically stop the generator

TPN ACCLThree Phase Automatic Changeover with Current Limiter

Quality Features

Current limitation on generator side

ACCL TPN/SPN WIRING ARRANGEMENTDURING INSTALLATION

ACCL TPN/TPN WIRING ARRANGEMENT DURING INSTALLATION

Technical Information

Standard Conformity IEC 60947-6-1

No. of Poles 3P+N

Rated current (In)40A/63A/95A on mains, 10-95A on generator

Rated voltage (Ue) 415 / 220 Vac

Rated frequency 50 Hz

Transfer Time 8-12 sec

Restoring Time 2-4 secRated Impulse Voltage (Uimp)

6kV

Utilization Category AC 31A

Class of Equipment PC

Environment B

IndicationMains, Generator, Load, Overload (R,Y,B), mode of operation (auto/manual)

Pollution Degree IIConditional Short Circuit Current

5kA

Ambient Temp. - 5 to + 55 ˚C

Electrical Life 6000 operations

Mounting Surface mounting

Mounting Position Vertical

Terminal Capacity 16 mm2 / 35 mm2

Duty Uninterrupted

Weight 4.5 Kg / 9.4 Kg

Dimensions260 x 243 x 115 mm3

260 x 243 x 150 mm3

383 x 333 x 150 mm3

DIMENSIONS (in mm)

Side Front

BAC

DE

In TPN/SPN, the ACCL will restrict the load if the cumulative current of

all the 3 phases (i.e. R+Y+B) exceeds rated generator current.

Main supply

MCB/RCCB

Load

Generator

L N

SCPD 2

R Y B N

SCPD 1

Auto GEN start control unit

MAINS LOAD IGNGEN

R Y B N R Y B N L N X1 X2

MAINS GEN40A 40A

DHACOTT4040

* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 95A TPN ACCL

In TPN/TPN, the ACCL will restrict the load if the current in any of the phase (i.e. R or Y or B) exceeds rated generator current.

Main supply

MCB/RCCB

Load

Generator

R Y B N

SCPD 2

R Y B N

SCPD 1

Auto GEN start control unit

MAINS LOAD IGNGEN

R Y B N R Y B N R Y B N X1 X2

MAINS GEN40A 40A

DHACOTT4040

* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 95A TPN ACCL

Page 38: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

AUTOMATIC SOURCE CHANGEOVER WITH CURRENT LIMITER (SPN ACCL)

7574

Perfection that Matters

SPN ACCL

An indispensable tool to automate power distribution, protect expensive gensets and prevent fatal risks - The power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply, and hence, most of the commercial and residential complexes set-up alternate power sources, such as gensets, to provide efficient back-up for their power needs. However, most of these users of alternate power still depend on manual change-over, which leads to issues such as increased downtime, disruption in key activities as well as critical damage to the expensive equipment and could also prove fatal to the operators.

Crabtree XPRO - Nation’s leading player in power distribution equipment and solutions, now offers Crabtree ACCL, a fully automatic high precision microcontroller based ‘Source Changeover’ device, which also has current limiting function and offers easy and ‘controllable’ changeover between main power supply and generator supply.

With these inherent strengths, Crabtree ACCL is being increasingly adopted by leading power consumers, both at commercial as well as residential levels, as a strong and proven power distribution management tool.

So go ahead, and empower your premises and power distribution with Crabtree ACCL today !

Functions- When the Mains Supply is available:a. The ACCL allows unrestricted supply from Mains in case current is in allowable limits.b. If the current exceed the mains rating, the load is disconnected after a delay of 5 seconds and it will remain disconnected for 8 seconds as a

warning and then automatically reconnects it. During this period, the consumer is expected to switch off the non-essential loads and bring it within the limit.

c. In an unlikely event, if the consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load from the mains is automatically disconnected after 5 cycles of interruption.

d. The supply from mains to the load can be restored after pressing the reset button present in the front of ACCL.

- When the Mains supply fails: Without AGS (automatic generator start features) - When the mains supply goes OFF, a consumer is automatically connected to the generator in

case generator supply is available after a time delay of 8 to 12 seconds in order to limit the sudden load on the generator. With AGS (automatic generator start features) - ACCL Provides signalling through a potential free contact for starting the Generator (Generator

must have control unit for auto Start/off) and then consumer is automatically connected to the generator after a time delay of 8 to 12 seconds in order to limit the sudden load on the generator.

Once the supply goes to generator side then:a. ACCL limits the user from drawing excess load current beyond the pre- set limit. b. If the current exceeds the allowable limit, the ACCL will indicate the overload condition by glowing its “overload” LED. Due to this the load is

disconnected after a delay of 5 seconds and will remain disconnected for 8 seconds as a warning and then automatically reconnects. During this period, the consumer is expected to switch off the non-essential loads and reduce it within the limit.

c. In an unlikely event, if the Consumer does not switch off the non-essential loads to reduce it to within the limit, supply to the load from the mains is automatically disconnected after 5 cycles of interruptions.

d. The supply from Gen to the load can be restored only after pressing the Reset button present in the front of ACCL.

SPN ACCLAutomatic Source Changeover with Current Limiter

Quality Features

with neutral isolation

between phase & neutral

ACCL WIRING ARRANGEMENT DURING INSTALLATION

Technical Information

Standard Conformity IEC 60947-6-1

No. of Poles 1P+N

Rated current (In) 30A on mains, 1.5-20A on generator

Rated voltage (Ue) 240 Vac

Rated frequency 50 Hz

Rated insulation voltage 500V

Transfer time 8 to 12 sec

Restoring Time 2 to 4 sec

Utilization Category AC 31A

Class of Equipment PC

Environment B

Indication Mains, Generator, Load, Overload

Ambient Temp. -5 to +55°C

Electrical Life 6000 operations

Rated Impulse Voltage 2.5kV

Duty Uninterrupted

Pollution Degree 2Conditional Short Circuit Current

3kA

Protection Class IP20

Mounting standard mounting RAIL (35x7.5 mm)

Mounting Position Vertical /Horizontal

Terminal Capacity mm² 10

Weight 350 g

71.8

87.5

Front view

36 45

63

44

6.8

Side view

DIMENSIONS (in mm)

L N

Main supply

N L

Input from mains supply

Input from GEN supply

Auto GEN start control unit

GEN with auto start control unit

Ignition signal to remote GEN start terminals

OutputMCB /RCCB

NLoad

ACCL

L

SCPD 1

SCPD 2

Terminals available in ACCL forGEN. ON/OFF feature

* SCPD can be 32A HRC FUSE or 32A MCB

Page 39: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Perfection that Matters

AUTOMATIC CHANGEOVER

7776

Perfection that Matters

Automatic Changeover

The Power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the Residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.

Automatic Changeover is a fully automatic high precision microcontroller based device and is ideally suited for unmanned power transfer operations in bungalows, multi storied appartments, commercial complexes, etc.

Functions- When the Mains Supply is available:a. Automatic Changeover allows full load current when the mains supply is available.b. Thus the load runs on the main supply after a time delay of 2 to 4 seconds

- When the Mains supply fails: With AGS (automatic generator start features)a. Automatic Changeover provides signaling through a potential free contact for starting the Generator. (Generator must have a control unit for auto

start/off) b. A consumer is automatically connected to the Generator supply after a time delay of 12 to 15 seconds in order to limit the sudden load on the

Generator.

Without AGS (automatic generator start features) a. When the mains supply goes off i.e. fails, automatic changeover will automatically sense and actuate the inbuilt changeover mechanism. b. A consumer is automatically connected to the Generator supply after a time delay of 12 to 15 seconds in order to limit the sudden load on the

Generator.

- When the Mains supply is restored:a. On resumption of the mains supply, the load is automatically transferred to the main supply after a time delay of 2 to 4 seconds.

AUTOMATIC CHANGEOVER

Microcontroller Based Design with Complete isolation of Neutral

LED indication of Status

DIN rail mountable, thus saving wall space and wiring

Consumes less power

Automatic Generator ON/OFF facility (on special demand)

Suitable/Compatible with the existing range

Quality Features

AUTOMATIC CHANGEOVER WIRING ARRANGEMENT DURING INSTALLATION

L N

Main supply

N L

Input from mains supply

Input from GEN supply

Auto GEN start control unit

GEN with auto start control unit

Ignition signal to remote GEN start terminals

OutputMCB /RCCB

NLoad

Automatic Changeover

AUTOMATICCHANGEOVER

L

SCPD 1

SCPD 2

Terminals available in Automatic Changeoverwith GEN. ON/OFF features only

Technical Information

Standard Conformity IEC 60947-6-1

No. of Poles 1P+N

Rated current (Ith) 30A

Rated voltage (Ue) 240 Vac

Rated frequency 50 Hz

Rated insulation voltage 500 V

Supply voltage 80-300 Vac

Restoring Time 2 to 4 secMains to Gen transfer time

12 to 15 sec

Rated impulse voltage (Uimp)

2.5 kV

Utilization Category AC 31BConditional short circuit current

3 kA

Indication Mains, Generator, Load

Degree of protection IP-20

Ambient Temp. -5 to +55

Electrical Life 6000 operations

Mounting Standard mounting RAIL (35x7.5 mm)

Mounting Position Vertical /Horizontal

Terminal Capacity mm² 10

Weight 365 gm

Dimensions (in mm) 87.5 x 71.8 x 63 71.8

87.5

Front view

36 45

63

44

6.8

Side view

DIMENSIONS (in mm)

Page 40: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

78 79

Perfection that Matters

TIME SWITCH

Quality Features

Digital Time Switch with daily & weekly program

Text oriented user guidance in display

Program repeatability with 8 ON/OFF setting for Digital Programmable & 6 ON/OFF setting for

Astronomical Time Switch

150 hours running reserve for Digital Programmable Time Switch & 24 Hour Programmable

Time Switch & 48 hours running reserve for Astronomical Time Switch

Minimum Switching Time

- 1 Min. for Digital Programmable & Astronomical Time Switch

- 15 Min. for 24 Hour Programmable Time Switch

General CharacteristicsCrabtree introduces the new XPRO range of Time Switches. The range offers a variety of feature benefits such as Controlling the opening and closing of electrical circuits according to a scheduled program, Minimum switching time, Internal battery to enable the timing function in case of power failure, Daily and weekly versions, Simple and compact design.

Page 41: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

81

Perfection that Matters

TIME SWITCH

80

Perfection that Matters

Technical Information

Operating Voltage 230 Vac

Rated Frequency 50 – 60 Hz

Width 54.5 mm

Weight 0.2 kg

Installation Type DIN Rail

Type of Contact Changeover Contact

Program Fuctions ON / OFF

Switching Segments 48

Power Reserve 150 Hrs

Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A

Max. Switching Capacity at 250 VAC, cosΦ = 0.6 4 A

Incandescent / Halogen Lamps 1100 watt

Shortest Switching Time 15 Min

Mechanical Life 107

Electrical Life 105

Time Accuracy 1 s/day Quartz

Power Consumption 5 VA

Degree of Protection IP 20

Ambient Temperature -10 ºC to + 55 ºC

24-Hour Analog Time Switch has a 24-hour dial and is used to switch an electrical circuit “ON” or “OFF” at selected times, during a period of time programmed in advance. The start of the programme has to be set on the dial by pulling a segment on the desired time.

Applications: The 24 Hour Analog Time Switch is used in pre-programmed switching of:

ANALOG TIME SWITCH (15 MINUTES)

Load

Main supply220V

01

Quartz

11

1

1 0

24

8

6

10

61214 16

18

3

2022

24

9

1 2 3

L N~

110-230V~50-60Hz

8mm

16(4)250~

2.5mm0.5mm

L N

0

0 0

Load 2Load

Main supply220V

01

Quartz

11

1

1 0

24

8

6

10

61214 16

18

3

2022

24

9

1 2 3

L N~

110-230V~50-60Hz

8mm

16(4)250~

2.5mm0.5mm

L N

0

0 0

Load

Main supply220V

01

Quartz

11

1

1 0

24

8

6

10

61214 16

18

3

2022

24

9

1 2 3

L N~

110-230V~50-60Hz

8mm

16(4)250~

2.5mm0.5mm

L N

0

0 0 66max

36

93m

ax

54max

0

1

Quartz

11

1

1 0

24

8

6

10

61214 16

18

3

2022

24

9

1 2 3

L N~

110-230V~50-60Hz

8mm

16(4) 250~

2.5mm²0.5mm²

L N

0

0 0

For example Consider an Electric Heater in connection with Analog Time Switch

Single Load Multiple Load

Dimension (in mm)

WIRING DIAGRAM

Page 42: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

83

Perfection that Matters

TIME SWITCH

82

Perfection that Matters

Technical Information

Operating Voltage 240 Vac

Rated Frequency 50 Hz

Width 36 mm

Weight 0.150 kg

Installation Type DIN Rail

Type of Contact Changeover Contact

Program Weekly Program

Program Fuctions ON / OFF

Number of Memory Locations 56

Power Reserve 150 Hrs

Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A

Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A

Incandescent / Halogen Lamps 2300 watt

Shortest Switching Time 1 Min

Mechanical Life 107

Electrical Life 105

Time Accuracy 1 s/day

Power Consumption 5 VA

Degree of Protection IP 20

Ambient Temperature -10 ºC to + 55 ºC

Time Switches are offered in order to guarantee the opening & closing of electrical circuits according to the scheduled program. Crabtree offers four types of time switches to satisfy the user requirement.

Programmable Time Switch automatically turns lighting or other loads on/off when the programmed on/off time expires. Depending on the day of the week (Mon - Sun) different daily programs can be configured.

Applications: The programmable time switch can be used in pre – programmed switching of:

DIGITAL PROGRAMMABLE TIME SWITCH (WEEKLY)

Load

Main supply220V

Load 1 Load 2

Main supply220V

82

36 66

45.5

Main supply220V

Load

For example Consider an Electric Heater in connection with Programmable Time Switch

Single Load Multiple Load

Dimension

WIRING DIAGRAM

Page 43: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

85

Perfection that Matters

TIME SWITCH

84

Perfection that Matters

Technical Information

Operating Voltage 240 Vac

Rated Frequency 50 Hz

Width 36 mm

Weight 0.125 kg

Installation Type DIN Rail

Type of Contact Changeover Contact

Program Fuctions ON / OFF

Number of Memory Locations 54

Power Reserve 48 Hrs

Max. Switching Capacity at 250 VAC, cosΦ = 1 6 A

Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A

Incandescent / Halogen Lamps 1000 watt

Shortest Switching Time 1 Min

Mechanical Life 107

Electrical Life 105

Time Accuracy 2 s/day

Power Consumption < 4 VA

Degree of Protection IP 20

Ambient Temperature -10 ºC to + 40 ºC

Astronomical Programmable Time Switch automatically adjusts the set time along with seasonal variation to control ON/OFF for lighting on purpose of realizing that light is turned on when sun sets & turned off when sun rises.

Applications: The Astronomical Time Switch is used in controlling:

ASTRONOMICAL PROGRAMMABLE TIME SWITCH (WEEKLY)

Load

Main supply220V

Load 1 Load 2

Main supply220V

Main supply220V

LoadLoad 82

36 66

45.5

Single Load Multiple Load

For example Consider an Electric Bulb in connection withAstronomical Programmable Time Switch

Dimension

WIRING DIAGRAM

Page 44: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

87

Perfection that Matters

TIME SWITCH

86

Perfection that Matters

Technical Information

Operating Voltage 240 Vac

Rated Frequency 50 Hz

Width 17.5 mm

Weight 0.075 kg

Installation Type DIN Rail

Adjustment Range 0.5 - 20 Min

Type of Contact NO Contact

Type of Connection 3-/4- conductor

Max. Switching Capacity at 250 Vac, cosΦ = 1 16 A

Max. Switching Capacity at 250 Vac, cosΦ = 0.6 10 A

Incandescent / Halogen Lamps 2300 watt

Switch for Permanent Light Sliding Switch

Degree of Protection IP 20

Ambient Temperature -10 ºC to + 55 ºC

Staircase Light Time Switch is a variable delay timer to control stairwell lighting. A momentary action push button will initiate its output, which will then ‘time out’ after a pre – set delay has elapsed.

Applications: The Staircase Light Time Switch is specifically used in controlling stairwell lighting in multiplexes, hotels, offices etc.

STAIRCASE LIGHT TIME SWITCH

85 45

17.560

44

Switch 1

Bulb 2

Main supply220V

Bulb 3

Bulb 1

Switch 2

Switch 3

DimensionFor example

WIRING DIAGRAM3 Wire Connection 4 Wire Connection

Page 45: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

89

Perfection that Matters

TIME SWITCH

88

Perfection that Matters

Technical Information

Operating Voltage 220 - 240 Vac

Rated Frequency 50 Hz

Width 54.5 mm

Weight 0.2 kg

Installation Type DIN Rail

Type of Contact Changeover Contact

Program Fuctions ON / OFF

Number of Memory Locations 48

Power Reserve 150 Hrs

Max. Switching Capacity at 250 VAC, cosΦ = 1 16 A

Max. Switching Capacity at 250 VAC, cosΦ = 0.6 10 A

Incandescent / Halogen Lamps 2300 watt

Shortest Switching Time 15 Min

Mechanical Life 107

Electrical Life 105

Time Accuracy 1 s/day

Power Consumption 5 VA

Degree of Protection IP 20

Ambient Temperature -10 ºC to + 55 ºC

24 Hour Programmable Time Switch has a 24h dial and is used to switch an electrical circuit “ON” or “OFF” at selected times during a period of time programmed in advance. A program consists of a closing time and an opening time for a circuit.

Applications: The 24 Hour Programmable Electronic Time Switch is used in pre – programmed switching of:

24 HOUR PROGRAMMABLE TIME SWITCH

Load 1 Load 2

Main supply220V

Load

Main supply220V

Main supply220V

Load

4585

54.5

20

6649

Single Load Multiple Load

Dimension

WIRING DIAGRAM

For example Consider an Electric lamp in connection with24 Hour Programmable Time Switch

Page 46: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

90

Perfection that Matters

Distribution Boards at Glance

91

Perfection that Matters

POWER SERIES DISTRIBUTION BOARDS CLASSIQUE DISTRIBUTION BOARDS

SPN Double Door Distribution BoardTPN Per Phase Isolation Double Door Distribution Board

TPN Double Door Vertical Distribution Board

SPN Double Door Distribution Board

TPN Double Door Horizontal Distribution Board

8 - Segment Double Door Distribution Board

Automatic Phase Selector Double Door Distribution Board with 32A Automatic Phase Selector

Phase Selector Double Door Horizontal Distribution Board with 40/ 63A Rotary Switch

No. of Ways 4, 6, 8, 12 & 16 Ways 2+4, 2+6, 2+8 & 2+12 Ways 4, 8 & 12 Ways 4, 6, 8, 12 & 16 Ways 4, 6, 8 & 12 Ways 4, 6, 8 & 12 Ways 4 & 6 Ways 4,6 & 8 Ways

Type of Installation Surface Flush / Surface Surface Flush / Surface Flush / Surface Flush / Surface Flush / Surface Surface

Colour / Finish Bucket White / Texture Finish Bucket White / Texture Finish Bucket White / Texture Finish Bucket White / Texture FinishBucket White / Texture Finish

Bucket White / Texture Finish

Bucket White / Texture FinishBucket White / Texture Finish

Door Options Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version Flat Version

Sheet Thickness (mm)

1.0 mm 1.0 mm 1.2 mm 1.0 mm 1.0 mm 1.2 mm 1.0 mm 1.0 mm

Door Locking Options

Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock Barrel Key Lock

Removable Gland Plates

Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom Top & Bottom

Protection Level of Distribution Boards

Advanced Advanced Advanced Standard Standard Standard Advanced Standard

Distribution Technique

Straight Busbar Straight Busbar Fish-bone Busbar Straight Busbar Straight Busbar Straight Busbar Straight Busbar Straight Busbar

Busbar Rating 100 A 125 A 125 A 100 A 100 A 100 A 125 A 100 A

Busbar Short Time Withstand (Icw)

5 kA for 0.1 second 5 kA for 0.1 second 10 kA for 0.5 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second 5 kA for 0.1 second

Busbar Conditional Short Circuit (Ics)

15 kA 10 kA 25 kA 10 kA 10 kA 10 kA 10 kA 10 kA

Incoming Max. 100 A Max. 100 A Max. 125 A Max. 100 A Max. 100 A Max. 63 A per phase Max. 63 A Max. 63 A per phase

Outgoing Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 63 A Max. Individual 32 A Max. Individual 32 A

Voltage Rating 240 Vac, 1 Phase 240-415 Vac, 3 Phase / 4 Wire 240-415 Vac, 3 Phase / 4 Wire 240 Vac, 1 Phase240-415 Vac, 3 Phase / 4 Wire

240-415 Vac, 3 Phase / 4 Wire

240-415 Vac, 3 Phase / 4 Wire

240-415 Vac, 3 Phase / 4 Wire

Incoming OptionsUp to 100 A Isolator (2P) or 100 A RCCB (2P)

100 A Isolator (4P) or 100 A RCCB (4P)

Up to 125 A Isolator (4P, 3P & 2P) or 100 A RCCB

100 A Isolator (2P) or 100 A RCCB (2P)

100 A Isolator (4P) ; 100A RCCB

100 A Isolator (4P) & 100 A RCCB (4P) or RCBO (4P)

63 A Isolator or 63 A RCCB & 63 A MCB

100 A Isolator & R, Y, B Indicating Lights (3P+N) & 100 A RCCB

Residual Current Protective Devices Options

RCCB as Incomer / RCBO as Outgoing

RCCB as Incomer / RCBO as Outgoing

RCCB as Incomer / RCBO as Outgoing

RCCB or RCBO as IncomerRCCB or RCBO as Incomer

RCCB or RCBO as Incomer

RCCB or RCBO as Incomer RCCB or RCBO as Incomer

Neutral Bar Terminal Capacity

25 mm2 25 mm2 25 mm2, Split on both sides 16 mm2 16 mm2 16 mm2 25 mm2 16 mm2

Earthing Bar Terminal Capacity

25 mm2 25 mm2 25 mm2, Split on both sides 16 mm2 16 mm2 16 mm2 25 mm2 16 mm2

Index of Protection (IP)

IP 2X / IP 42 IP 2X / IP 42 IP 2X / IP 42 IP 43 IP 43 IP 42 IP 2X / IP 42 IP 42

Insulation Voltage (Ui)

690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac 690 Vac

Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

Ambient Temperature

-5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C -5° C to 40° C

Distribution Board - Reference Standard

IS 8623 ; IS 13032 ; IEC 61439-3 IS 8623 ; IS 13032 ; IEC 61439-3 IS 8623 ; IS 13032 ; IEC 61439-3IS 8623 ; IS 13032 ; IEC 61439-3

IS 8623 ; IS 13032 ; IEC 61439-3

IS 8623 ; IS 13032 ; IEC 61439-3

IS 8623 ; IS 13032 ; IEC 61439-3

IS 8623 ; IS 13032 ; IEC 61439-3

Protective Devices - Reference Standard

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

IS/IEC 60947-2 ; IS/IEC 60898 ; IS/IEC 60947-3

Residual Current Protective Devices - Reference Standard

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

IS 12640 : Part1 & 2 ; IEC 61008 ; IEC 61009

Index of Protection (IP) - Reference Standard

IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529 IS/IEC 60529

Page 47: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

92 93

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

XPRO Classique Distribution board*

NO. OF WAYS I/C+O/G CAT NO. (DD)

TPN TPN TPN

4 8+12 DCDKTHODCW04

6 8+18 DCDKTHODCW06

8 8+24 DCDKTHODCW08

12 8+36 DCDKTHODCW12

- - -

NO. OF WAYS I/C+O/G CAT NO. (DD)

SPN SPN SPN

4 4 DCDKSHODCW04

6 6 DCDKSHODCW06

8 8 DCDKSHODCW08

12 12 DCDKSHODCW12

16 16 DCDKSHODCW16

NO. OF WAYS I/C+O/G CAT NO. (DD)

SPN SPN SPN

4 4 DCDKSHCDXW04

6 6 DCDKSHCDXW06

8 8 DCDKSHCDXW08

12 12 DCDKSHCDXW12

16 16 DCDKSHCDXW16

NO. OF WAYS I/C+O/G CAT NO. (DD)

TPN TPN TPN

4 8+12 DCDKTHCDXW04

6 8+18 DCDKTHCDXW06

8 8+24 DCDKTHCDXW08

12 8+36 DCDKTHCDXW12

- - -

Classique - II Distribution Board - SPN

Classique - II Distribution Board - TPN

Classique Distribution Board - TPN

Classique Distribution Board - SPN

XPRO Classique Distribution board*

NO. OF WAYS I/C+O/G CAT NO. (DD)

4 8+12 DCDKTHPDXW04

6 8+18 DCDKTHPDXW06

8 8+24 DCDKTHPDXW08

TP&N PPI Distribution Board

NO. OF WAYS CAT NO. (DD)

4 DCDKTHDDCW04

6 DCDKTHDDCW06

8 DCDKTHDDCW08

12 DCDKTHDDCW12

8 Segment DD Distribution BoardIP 42 Double Door DB; Steel Sheet, Phosphatised, powder Painted MCB distribution Board with Busbar, neutral link, Earth Bar and Din Rail. As per Tamilnadu Inspectorate specification

NO. OF WAYS Rating * ** CAT NO. (DD)

4 32A* DCDAKHDCZ04032

6 32A* DCDAKHDCZ06032

Classique Plus Automatic Phase Selector DB

Note: Supplied with 63 A, 4 P MCB as incomer.* Changeover Capacity Per Phase** 63A Current Carrying Capacity Per Phase

NO. OF WAYS Rating CAT NO. (DD)

4 40 DCDSMACCZ04040

4 63 DCDSMACCZ04063

6 40 DCDSMACCZ06040

6 63 DCDSMACCZ06063

8 40 DCDSMACCZ08040

8 63 DCDSMACCZ08063

Classique Plus Manual Phase Selector Horizontal DBFitted with 3nos Rotary switch

Page 48: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

94 95

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

XPRO Classique Distribution board*

DESCRIPTION CAT NO.

20 A DP PLUG ASSEMBLY SPLX0035

20 A DP SOCKET ASSEMBLY SPLX0036

30 A TP PLUG ASSEMBLY SPLX0037

30 A TP SOCKET ASSEMBLY SPLX0038

Plug & SocketXPRO Spares

Plug & Socket Board

AMP DESCRIPTION CAT NO. (DD)

20 SPN DCDPUSN020

20 DP DCDPUDN020

30 TPN DCDPUTN030

MCB Enclosure Plastic

NO. OF POLES DESCRIPTION CAT NO.

2 PLASTIC DCDEPDP

4 PLASTIC DCDEPFP

MCB Enclosure Steel

NO. OF POLES DESCRIPTION CAT NO.

2 SS DCDESDP

4 SS DCDESFP

Timer Distribution Board

DESCRIPTION CAT NO. (DD)

TPN Timer Classique DB with Timer Switch DCDIN002

Modular Contactor TPN 40A

DESCRIPTION CAT NO. (DD)

Modular Contactor TPN 40A DSCPGMDBX436

XPRO Power Series Distribution board*

NO. OF WAYS I/C+O/G CAT NO. (DD)

4 4 DCDMSHODCW04

6 6 DCDMSHODCW06

8 8 DCDMSHODCW08

12 12 DCDMSHODCW12

16 16 DCDMSHODCW16

TP&N PPI Distribution Board

NO. OF WAYS I/C+O/G CAT NO. (DD)

2+4 4+6+12 DCDKTHPDCW04

2+6 4+6+18 DCDKTHPDCW06

2+8 4+6+24 DCDKTHPDCW08

2+12 4+6+36 DCDKTHPDCW12

Per Phase Isolation (PPI) Vertical - 4 Tier

NO. OF WAYS CAT NO. Isolator I/C** CAT NO. MCB I/C***

4 DCDKTVODCW04 DCDLVDCBMAFC04

8 DCDKTVODCW08 DCDLVDCBMAFC08

12 DCDKTVODCW12 DCDLVDCBMAFC12

TP&N Vertical

** Suitable for MCB/Isolator as I/C upto 63A*** Suitable for MCB as I/C upto 80-125A

NO. OF WAYS CAT NO.* DESCRIPTION

4 DCDLVDCBGSTE04 Suitable For FP ‘G’ Frame’ MCCB

8 DCDLVDCBGSTE08 Suitable For FP ‘G’ Frame’ MCCB

12 DCDLVDCBGSTE12 Suitable For FP ‘G’ Frame’ MCCB

FP Vertical (with MCCB as Incomer)

* Suitable for MCCB as I/C upto 160A, for appropriate MCCB price, please see Havells IP Price list

NO. OF WAYS CAT NO. (DD)

4 DCDLVDCBGHFO04

6 DCDLVDCBGHFO06

8 DCDLVDCBGHFO08

12 DCDLVDCBGHFO12

TPN Vertical Load Line

NO. OF WAYS CAT NO. (DD)

2 X 13 DCDKTHZDCW13

3 X 13 DCDKTHYDCW13

4 X 13 DCDKTHXDCW13

Flexy Double Door Distribution Board

Page 49: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

96 97

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

SP ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCSPF0x5-005

6-32 DCMJCSPF006-032

40 DCMJCSPF040

50 DCMJCSPF050

63 DCMJCSPF063

DP ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCDPF0x5-005

6-32 DCMJCDPF006-032

40 DCMJCDPF040

50 DCMJCDPF050

63 DCMJCDPF063

TP ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCTPF0x5-005

6-32 DCMJCTPF006-032

40 DCMJCTPF040

50 DCMJCTPF050

63 DCMJCTPF063

FP ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCFPF0x5-005

6-32 DCMJCFPF006-032

40 DCMJCFPF040

50 DCMJCFPF050

63 DCMJCFPF063

SP&N ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCSNF0x5-005

6-32 DCMJCSNF006-032

40 DCMJCSNF040

50 DCMJCSNF050

63 DCMJCSNF063

TP&N ‘C’ Curve Series

RATING CODE

0.5-5 DCMJCTNF0x5-005

6-32 DCMJCTNF006-032

40 DCMJCTNF040

50 DCMJCTNF050

63 DCMJCTNF063

MCB Higher Rating DP ‘C’ Series

RATING CODE

80 DCMJCDPF080

100 DCMJCDPF100

125 DCMJCDPF125

MCB Higher Rating TP ‘C’ Series

RATING CODE

80 DCMJCTPF080

100 DCMJCTPF100

125 DCMJCTPF125

MCB Higher Rating FP ‘C’ Series

RATING CODE

80 DCMJCFPF080

100 DCMJCFPF100

125 DCMJCFPF125

RATING CODE

80 DCMJCSPF080

100 DCMJCSPF100

125 DCMJCSPF125

MCB Higher Rating SP ‘C’ Series

Page 50: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

98 99

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

MCB SP ‘D’ Series

RATING CODE

0.5-5 DCMJDSPF0x5-005

6-32 DCMJDSPF006-032

40 DCMJDSPF040

50 DCMJDSPF050

63 DCMJDSPF063

MCB DP ‘D’ Series

RATING CODE

0.5-5 DCMJDDPF0x5-005

6-32 DCMJDDPF006-032

40 DCMJDDPF040

50 DCMJDDPF050

63 DCMJDDPF063

MCB TP ‘D’ Series

RATING CODE

0.5-5 DCMJDTPF0x5-005

6-32 DCMJDTPF006-032

40 DCMJDTPF040

50 DCMJDTPF050

63 DCMJDTPF063

MCB FP ‘D’ Series

RATING CODE

0.5-5 DCMJDFPF0x5-005

6-32 DCMJDFPF006-032

40 DCMJDFPF040

50 DCMJDFPF050

63 DCMJDFPF063

RATING CODE

40 DCMFOSPX040

63 DCMFOSPX063

Isolator SP

RATING CODE

80 DCMFODPX080

100 DCMFODPX100

125 DCMFODPX125

Higher Rating Isolator DP

RATING CODE

80 DCMFOFPX080

100 DCMFOFPX100

125 DCMFOFPX125

Higher Rating Isolator FP

RATING CODE

80 DCMFOTPX080

100 DCMFOTPX100

125 DCMFOTPX125

Higher Rating Isolator TP

RATING CODE

40 DCMFODPX040

63 DCMFODPX063

Isolator DP

RATING CODE

40 DCMFOTPX040

63 DCMFOTPX063

Isolator TP

RATING CODE

40 DCMFOFPX040

63 DCMFOFPX063

Isolator FP

Page 51: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

100 101

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

DESCRIPTION CODE

30A W/O GEN START/STOP DCAAOSN3030

30A with GEN START/STOP DCAAWSN3030

Automatic Changeover

TPN ACCLTPN ACCL (TPN/SPN) (Automatic Source Changeover with Current Limiter)

GEN RATING

DESCRIPTIONCAT. NO. WITHOUT GEN START/STOP

CAT. NO. WITH GEN START/STOP

20A 40A/20A TPN/SPN ACCL DCACOTN4020 DCACWTN4020

25A 40A/25A TPN/SPN ACCL DCACOTN4025 DCACWTN4025

30A 40A/30A TPN/SPN ACCL DCACOTN4030 DCACWTN4030

40A 40A/40A TPN/SPN ACCL DCACOTN4040 DCACWTN4040

20A 63A/20A TPN/SPN ACCL DCACOTN6320 DCACWTN6320

25A 63A/25A TPN/SPN ACCL DCACOTN6325 DCACWTN6325

30A 63A/30A TPN/SPN ACCL DCACOTN6330 DCACWTN6330

40A 63A/40A TPN/SPN ACCL DCACOTN6340 DCACWTN6340

63A 80A/63A TPN/SPN ACCL DCACOTN8063 -

TPN ACCL (TPN/TPN) (Automatic Source Changeover with Current Limiter)

GEN RATING

DESCRIPTIONCAT. NO. WITHOUT GEN

START/STOPCAT. NO. WITH GEN

START/STOP

20A 40A/20A TPN/TPN ACCL DCACOTT4020 DCACWTT4020

25A 40A/25A TPN/TPN ACCL DCACOTT4025 DCACWTT4025

30A 40A/30A TPN/TPN ACCL DCACOTT4030 DCACWTT4030

40A 40A/40A TPN/TPN ACCL DCACOTT4040 DCACWTT4040

20A 63/20A TPN/TPN ACCL DCACOTT6320 DCACWTT6320

25A 63/25A TPN/TPN ACCL DCACOTT6325 DCACWTT6325

30A 63/30A TPN/TPN ACCL DCACOTT6330 DCACWTT6330

40A 63/40A TPN/TPN ACCL DCACOTT6340 DCACWTT6340

63A 80/63A TPN/TPN ACCL DCACOTT8063 -

SPN ACCL (Automatic Source Changeover with Current Limiter)

GEN RATING DESCRIPTIONCAT. NO. WITHOUT GEN START/STOP

CAT. NO. WITH GEN START/STOP

SPN 1.5 (300W) 30A/1.5A ACCL DCABOSN301X -

SPN 2.5 (500W) 30A/2.5A ACCL DCABOSN302X -

SPN 3 (600W) 30A/03A ACCL DCABOSN3003 DCABWSN3003

SPN 4 (800W) 30A/04A ACCL DCABOSN3004 -

SPN 5 (1000W) 30A/05A ACCL DCABOSN3005 -

SPN 6 (1200W) 30A/06A ACCL DCABOSN3006 DCABWSN3006

SPN 9 (1800W) 30A/09A ACCL DCABOSN3009 DCABWSN3009

SPN 12 (2400W) 30A/12A ACCL DCABOSN3012 DCABWSN3012

SPN 15 (3000W) 30A/15A ACCL DCABOSN3015 DCABWSN3015

SPN 20 (4000W) 30A/20A ACCL DCABOSN3020 DCABWSN3020

DP RCCB ‘AC’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

16 DCRJCMDF030016 DCRJCMDF100016 DCRJCMDF300016

25 DCRJCMDF030025 DCRJCMDF100025 DCRJCMDF300025

32 DCRJCMDF030032 DCRJCMDF100032 DCRJCMDF300032

40 DCRJCMDF030040 DCRJCMDF100040 DCRJCMDF300040

63 DCRJCMDF030063 DCRJCMDF100063 DCRJCMDF300063

FP RCCB ‘AC’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

25 DCRJCMFF030025 DCRJCMFF100025 DCRJCMFF300025

40 DCRJCMFF030040 DCRJCMFF100040 DCRJCMFF300040

63 DCRJCMFF030063 DCRJCMFF100063 DCRJCMFF300063

DP RCCB ‘A’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

16 DCRJAMDF030016 DCRJAMDF100016 DCRJAMDF300016

25 DCRJAMDF030025 DCRJAMDF100025 DCRJAMDF300025

32 DCRJAMDF030032 DCRJAMDF100032 DCRJAMDF300032

40 DCRJAMDF030040 DCRJAMDF100040 DCRJAMDF300040

63 DCRJAMDF030063 DCRJAMDF100063 DCRJAMDF300063

DP Higher Rating RCCB ‘AC’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

80 DCRJCMDF030080 DCRJCMDF100080 DCRJCMDF300080

100 DCRJCMDF030100 DCRJCMDF100100 DCRJCMDF300100

FP RCCB ‘A’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

16 DCRJAMFF030016 DCRJAMFF100016 DCRJAMFF300016

25 DCRJAMFF030025 DCRJAMFF100025 DCRJAMFF300025

32 DCRJAMFF030032 DCRJAMFF100032 DCRJAMFF300032

40 DCRJAMFF030040 DCRJAMFF100040 DCRJAMFF300040

63 DCRJAMFF030063 DCRJAMFF100063 DCRJAMFF300063

FP Higher Rating RCCB ‘AC’ Type

RATING 30mA CODE 100mA CODE 300mA CODE

80 DCRJCMFF030080 DCRJCMFF100080 DCRJCMFF300080

100 DCRJCMFF030100 DCRJCMFF100100 DCRJCMFF300100

Page 52: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

102 103

Product ProductOrdering information Ordering information

Perfection that MattersPerfection that Matters

RATING SENSITIVITY CODE

6A 30mA DCBJACSP1030006

10A 30mA DCBJACSP1030010

16A 30mA DCBJACSP1030016

20A 30mA DCBJACSP1030020

25A 30mA DCBJACSP1030025

32A 30mA DCBJACSP1030032

40A 30mA DCBJACSP1030040

50A 30mA DCBJACSP1030050

RCBO - A Type (SP&N -1M)

RCBO - A Type (SP&N - 2M)

RCBO - A Type (TP&N - 4M)

RATING 30mA CODE 100mA CODE 300mA CODE

6A DCBJACSN2030006 DCBJACSN2100006 DCBJACSN2300006

10A DCBJACSN2030010 DCBJACSN2100010 DCBJACSN2300010

16A DCBJACSN2030016 DCBJACSN2100016 DCBJACSN2300016

20A DCBJACSN2030020 DCBJACSN2100020 DCBJACSN2300020

25A DCBJACSN2030025 DCBJACSN2100025 DCBJACSN2300025

32A DCBJACSN2030032 DCBJACSN2100032 DCBJACSN2300032

40A DCBJACSN2030040 DCBJACSN2100040 DCBJACSN2300040

RATING 30mA CODE 100mA CODE 300mA CODE

6A DCBJACTN4030006 DCBJACTN4100006 DCBJACTN4300006

10A DCBJACTN4030010 DCBJACTN4100010 DCBJACTN4300010

16A DCBJACTN4030016 DCBJACTN4100016 DCBJACTN4300016

20A DCBJACTN4030020 DCBJACTN4100020 DCBJACTN4300020

25A DCBJACTN4030025 DCBJACTN4100025 DCBJACTN4300025

32A DCBJACTN4030032 DCBJACTN4100032 DCBJACTN4300032

40A DCBJACTN4030040 DCBJACTN4100040 DCBJACTN4300040

Auxiliary Contact For RCCB

DESCRIPTION CODE

1NO +NC (H &S) DSSRCX0027

Staircase Light Time Switch (0.5-20min)

S. NO. PRODUCT CODE

1 24 Hour Analog Time Switch (SST* - 15 min) DCTED15016

Staircase Light Time Switch (0.5-20min)

S. NO. PRODUCT CODE

1 Staircase Light Time Switch(0.5-20min) DCTCNx5016

24 Hour Programmable Time Switch

S. NO. PRODUCT CODE

1 Programmable Time Switch 24 Hrs DCTDD15016

Digital Programmable Time Switch

S. NO. PRODUCT CODE

1 Digital Time Switch with Weekly Program DCTAW01016

Astronomical Time Switch

S. NO. PRODUCT CODE

1 Astronomical Weekly Prog. Time Switch DCTBW01006

Page 53: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

105

Perfection that Matters

104

ProductOrdering information

Perfection that Matters

Indicator Light 1 Phase

COLOUR CODE

Red DCMJYSPX000

Green DCMJZSPX000

Blue DCMJVSPX000

Amber DCMJXSPX000

Clear DCMJWSPX000

Auxiliary Contact For MCB

DESCRIPTION CODE

1NO +NC (H &S) DSSMCX0190

Shunt Trip

RATING CODE

12V DCMJCDPF03221

24V DCMJCDPF03222

48V DCMJCDPF03223

240Vac DCMJCDPF03224

Indicator Light 3 Phase

COLOUR CODE

Red, Yellow, Blue DCMJWTPX000

Notes

Page 54: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

106

Perfection that Matters

Notes

Page 55: Perfection that Matters - Crabtree India · Busbar Conditional Short Circuit (Ics) 25 kA Incoming Max. 160 A Outgoing Max. Individual 63 A Voltage Rating 240-415 Vac, 3 Phase / 4

Havells India Ltd.Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-3331000 Email: [email protected], www.crabtreeindia.com Consumer Care No.: 1800 11 0303 (Tollfree),011-4166 0303 (Landline), 1800 103 1313 (All Connections)Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!CIN - L31900DL1983PLC016304

ZCE

PL0

0005

/AU

G16

/JU

NE

17

Regional & Branch Offices:

NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-3331000, Delhi: Tel: 011-47676700, 23888200, Chandigarh: Tel: 0172-4232400-401, Dehradun: Tel: 0135-6670202, Noida / Haryana: Tel: 0120-3331000, Ludhiana: Tel: 0161-4676000 / 24, Jammu: Tel: 0191-2478330, 2479330, Sri Nagar: Tel: 0194-2490431, Jaipur: Tel: 0141-3914645, 3988210 Jodhpur: Tel: 0291-9214201640 / 45, Lucknow: Tel: 0522-6672100, Kanpur: Tel: 0512-6710400, 6710409

EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52, Bhubaneshwar: Tel: 0674- 668101/102/103/104, Guwahati: Tel: 0361-2134521, 2458923, 2460355, Siliguri: Tel: 0353-2525907, Ranchi: 0651-2244861, 2244862, 2244864, 2244868, 2244869, Jamshedpur: Tel: 0657-6542492, 09234369436, Patna: Tel: 0612-2207221, 2207222, 2207223, 2655518

WEST - REGIONAL OFFICE: Mumbai: 1271, Solitaire Corporate Park, Bldg. No. 12, 7th Floor, Andheri - Ghatkopar Link Road, Chakala, Andheri (East), Mumbai-

400093. Ph.: 022 - 67298600-602 Ahmedabad: Tel: 079-40061111, 40060738-740, Indore: Tel: 0731-2572340-41, 4009998 (Airtel), Rajkot: Tel: 0281-2481112, 2921212, Nagpur: Tel: 0712-2240932, 2242692, 2242699 Pune: Tel: 020-64016413 / 14, Raipur: Tel: 0771-4243400 / 01, Surat: Tel: 0261-2350137, 9979890137, Jabalpur: Tel: 0761-4064491

SOUTH - REGIONAL OFFICE: Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008, Tel: 044-42280600, 605, Bangalore: Tel: 080-49075000, Coimbatore: Tel: 0422-4550200, 2305199, 2306199, Hyderabad: Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Kochi: Tel: 0484-4099000, Vizag: Tel: 0891-6514339, Vijayawada: Tel: +91-9247058847/57, Calicut: 0495-4019194, Madurai: 0452-4267022, Trivandrum: 0471-4015323, Hubli: 0836-4248600, Trichy: 09944460160