petroleum development oman l.l.c. sngp/kgp …...the scope of this project is to design and install...
TRANSCRIPT
![Page 1: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/1.jpg)
2
Printed: 05/05/2019 Printed copies of this document should be treated as information of temporary value and destroyed after use
Petroleum Development Oman L.L.C.
SNGP/KGP Firewater Network Project
Document ID Health Risk Assessment (HRA)
Document Type
Security Restricted
Discipline
Document Owner
Month and Year of Issue July 28th. 2016
Version 1.0
Keywords Occupational Health, Industrial Hygiene, Health hazards,
Document No
Copyright: This document is the property of Petroleum Development Oman, LLC. Neither the whole nor
any part of this document may be disclosed to others or reproduced, stored in a retrieval system, or
transmitted in any form by any means (electronic, mechanical, reprographic recording or otherwise) without
prior written consent of the owner.
![Page 2: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/2.jpg)
Document Authorisation
Document Owners Document Custodian
Fahad Abri GGE112 – Concept Project Engineer
Petrizzo, Jose, MCOH1
Revision History
The following is a brief summary of the four most recent revisions to this document. Details of all revisions
prior to these are held on file by the Document Custodian.
User Notes:
1. A controlled copy of the current version of this document is on PDO's live link. Before making reference to this document, it is the user's responsibility to ensure that any hard copy, or electronic copy, is current. For assistance, contact the Document Custodian.
2. Users are encouraged to participate in the ongoing improvement of this document by providing constructive feedback.
Related Business Processes & CMF Documents
Related Business Processes
Code Business Process (EPBM 4.0)
Version
No.
Month & Year Author’s Name and
Title
Scope / Remarks
1.0 July 28th. 2016 Jose F.Petrizzo
Ref. Ind: MCOH1
Issued for DEFINE to EXECUTE phase
![Page 3: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/3.jpg)
Parent Document(s)
Doc. No. Document Title
Other Related CMF Document(s)
Doc. No. Document Title
SP-1194 Chemical Management
SP 1230 Medical Examination, Treatment and Facilities
SP-1231 Occupational Health
SP-1232 Public Health
SP-1234 Personal Protective Equipment
PR-1243 Medical Emergency Response
PR-1418 Reporting and investigation of HSE incidents (Incident Notification, Reporting
and Follow-up Procedure Part 1)
PR-2108 Fit testing for Respirator Users
PR-2109 Legionella Management Program
PR-2111 Manual Material Handling
![Page 4: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/4.jpg)
Table of Contents
0. Introduction to the HRA report _________________________________________ 5
1. HRA Scope _________________________________________________________ 5
2. HRA Team __________________________________________________________ 6
3. Remedial Actions ____________________________________________________ 7
4. Health Hazard Inventory and Detailed Risk Appraisals_____________________ 13
5. Generic Controls, Recovery Measures and Remedial Actions _______________ 23
6. Control statements for Low RAM Hazards _______________________________ 24
Appendix 1: Definitions ________________________________________________ 25
Appendix 2: Risk Assessment Matrix _____________________________________ 27
![Page 5: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/5.jpg)
![Page 6: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/6.jpg)
0. Introduction to the HRA report
The Health Risk Assessment (HRA) report is used by PDO to process and store health related information. The report starts with a description of the scope of the HRA and the persons involved in sections 1 and 2. The remedial actions from the HRA are presented in report section 3, and are sorted by priority. Section 4 provides information from the detailed appraisals. The focus here is on High and Medium RAM rated risks. Section 5 provides an overview of generally applicable controls and recovery measures. Section 6 lists the status of the Low RAM rated risks that were reviewed during the HRA. The report concludes with definitions and a diagram of the RAM risk matrix in appendices 1 and 2.
1. HRA Project Scope
SNGP and KGP have no fixed active fire protection system. The concern was raised in PDO, and at that time as a result of a Fire Risk Level classification based on SP-1075 Rev. 3, these facilities have been classified as fire risk level 5. This is due to the strategic importance of both facilities and based on consequence groups for major credible fire and explosion scenarios. As per SP-1075 Rev. 3, the Fire Risk Level 5 facilities are of such importance that they require a comprehensive pre-fire planning type study addressing all credible fire scenarios. The outcome of this study will determine which fire safety measures are required to achieve ALARP level. Fire events at these facilities will have a major impact on the continued operation of the Company.
The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075 and DEP 80.47.10.31. The proposed firewater system as per the Concept Studies will consist of the following:
Two fire water tanks
Two fire pumps (1 Working+1 Standby), one is with electric motor and other one
is driven by diesel engine.
Two jockey pumps (1 Working+1 Spare) to maintain the system pressure
Fire water distribution network including hydrants, fixed monitors
Deluge system for required areas;
Foam system for required areas.
![Page 7: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/7.jpg)
2. HRA Team
Responsible for HRA: Petrizzo, Jose MCOH1 – Sr. Industrial Hygienist
Input Provided By: AL Hinai Suleiman MCOH6 – Industrial Hygienist Fahad Abri GGE112 – Concept Project Engineer Riyami, Ruwaa UEP1XH – Technical Safety Engineer Haider, Sajad UEP19G – FEED Project Engineer Khosravi, Hamid UEP11H – FEED HSE Engineer Geoffrey Murray GGO222 – OPS Support
![Page 8: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/8.jpg)
![Page 9: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/9.jpg)
3. Remedial Actions
Priority Work Area Hazard, RAM Rating and Scenario Recommended Remedial Action / Date / Resp. 1 SNGP/KGP FIREWATER
NETWORK PROJECT GENERIC CONTROLS 1. Site verification is required to finalize the
effectiveness of controls, recovery measures and final ALARP conditions mentioned in this HRA. Date: Q1 2019
Responsible: Project Team (GGE1)
+Operation+MCOH1
1 SNGP/KGP FIREWATER NETWORK PROJECT
GENERIC RECOVERY MEASURES 1. Emergency / safety showers: Select safety showers/eye wash stations that have the capability to cool water during summer period, according to PDO GU-817 Date: Q1 2018 Responsible: Project Team (GGE1)
![Page 10: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/10.jpg)
Priority Work Area Hazard, RAM Rating and Scenario Recommended Remedial Action / Date / Resp. 1
SNGP/KGP FIREWATER NETWORK PROJECT
Manual Handling - Lifting, Lowering,
carrying, pushing, pulling
Awkward Posture of the Shoulder, Neck,
Back (not associated with force)
Kneeling, Squatting, Standing on 1 leg,
Contact Stress on legs due low and high
walking displacement
Use of control Panel
RAM: Medium Operators, Maintenance and Technicians are required to move materials, open and close valves and manually manipulate controls.
1. Implement all HFE DEPs standards required by DCAF and follow only applicable remedial actions stated in Human Factors Engineering Screening report issued in June 2016 Date: Q2 2017 Responsible: Project Team (GGE1)
2 SNGP/KGP FIREWATER NETWORK PROJECT
Legionella bacteria (waterborne)
RAM: Medium All staff (on plot) has the potential to be exposed to the following Legionella sources: showers, aerolized water from fire water systems, and any scenario where ambient temperature water may become airborne and inhaled.
1. Review information about fire water design regarding aerosols, dead legs and stagnant water according to PDO PR-2109. (Review considering biocides injection at tanks and pumps)
Date: Q2 2017
Responsible: FEED / Execute Team
![Page 11: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/11.jpg)
Priority Work Area Hazard, RAM Rating and Scenario Recommended Remedial Action / Date / Resp. 2 SNGP/KGP FIREWATER
NETWORK PROJECT Noise
RAM: Medium All staff working on process facilities have the potential for exposure to plant noise and equipment. Potential sources of noise in process facilities are transfer pumps
1. Ask vendor for SPL output new pumps characteristic. Date: Q2 2017 Responsible: FEED Team
2. Ensure that separation distance between pumps is in
compliance with PDO SP-1127. Date: Q1 2018 Responsible: FEED Team
3 SNGP/KGP FIREWATER NETWORK PROJECT
Visible light (too much; too little) -
wavelength 400 - 780 nm (non-ionizing
radiation)
RAM: Low All staff are potentially exposed to insufficient lighting and poor night time illumination of the plant and facilities.
1. Process design/equipment standards - Confirm design in accordance with HFE DEP’s and FEED Emergency lightning guideline (GU/705).
Date: Q2 2017
Responsible: FEED Team
![Page 12: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/12.jpg)
4. Health Hazard Inventory and Detailed Risk Appraisals
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Diesel, Distillates, Gas Oils and Heating Oils
RAM: Medium
Acute Potential Health Effects
Slight irritant to eyes and on inhalation of mist RAM: 2C
Chronic Potential Health Effects
Defatting of the skin, dermatitis RAM: 3C
Scenario During filling or fuel replacement Route & Form of Exposure
Inhalation, Dermal, splash Liquid
Frequency & Duration of Exposure
Exposure Limit TWA: 100 mg/m3
Exposure Rating & Justification
ALARP Status Yes
Controls Effectiveness
Tank container with hose connection, closed system
Hazard identification by signs/warnings/labels - readily identifiable with labels, SHOC cards/SDS.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 13: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/13.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Batteries (Sulfuric Acid, sodium hydroxide lead inorganic, antimony)
RAM: Medium
Acute Potential Health Effects
Corrosive to skin and eyes. Respiratory irritant, may cause pulmonary edema RAM: 4C
Chronic Potential Health Effects
Lead: IARC 2A - Probably human carcinogenic. Neurological, blood, kidney effects. Toxic to reproduction and development. RAM: 4C
Scenario During segregation Route & Form of Exposure
Inhalation, Dermal, Splash Liquid, solid
Frequency & Duration of Exposure
Weekly 5 hours
Exposure Limit According to specific substance see Reference in TLVs and BEIs ACGIH last version
Exposure Rating & Justification
Low (10%-50% OEL) Batteries are sealed
ALARP Status Yes ALARP Justification Controls in place Controls Effectiveness
Hazard identification by signs/warnings/labels - Where used as diluents, agent usually well labeled with either MSDS or SHOC cards or both.
Training and information on hazard - Adequate hazard information and training communicated to the workers.
Safety Manual, Written protocols: SP-1009
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 14: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/14.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Diesel exhaust
RAM: Medium
Acute Potential Health Effects
Irritant to eyes and respiratory tract RAM: 2C
Chronic Potential Health Effects
IARC 2A Probably carcinogenic RAM: 4B
Scenario In field operations while equipment combustion Route & Form of Exposure
Inhalation fumes
Frequency & Duration of Exposure
Exposure Limit Shell OEL: 0.1 mg Elemental Carbon/m3, as respirable particulate
Exposure Rating & Justification
ALARP Status Yes ALARP Justification Controls in place Controls Effectiveness
Local control – natural ventilation open spaces Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 15: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/15.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Unknown chemicals during an emergency
RAM: Medium
Acute Potential Health Effects
Various including irritation, asphyxiation, burns (if corrosive) RAM: 4B
Chronic Potential Health Effects
Dependant of the chemical potential damage (systemic, carcinogen). RAM: 4B
Scenario During an emergency (fire, reactions, combustion) Route & Form of Exposure
Inhalation Gas, Vapors and Fumes
Frequency & Duration of Exposure
Exposure Limit
Exposure Rating & Justification
ALARP Status Yes ALARP Justification Controls in place Controls Effectiveness
PPE – Respirators and SCBA
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 16: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/16.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Manual Handling - Lifting, Lowering, carrying, pushing, pulling
Awkward Posture of the Shoulder, Neck, Back (not associated with force)
Kneeling, Squatting, Standing on 1 leg, Contact Stress on legs due low
and high walking displacement
Use of control Panel
RAM: Medium
Acute Potential Health Effects
Acute strain or sprain to muscles and joints. Muscular fatigue or discomfort, may include numbness in the legs. Strain or sprain RAM: 3C
Chronic Potential Health Effects
Chronic musculo-skeletal disorders. Lower body joint disorders RAM: 3D
Scenario Operators, Maintenance and Technicians are required to move materials, open and close valves, manually manipulate controls and computers.
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit
Exposure Rating & Justification
ALARP Status NO
ALARP Justification Verification of controls and Site review
Controls Effectiveness
Process design/equipment standards - Design include HFE DEP 30 00 60 10. 3D model reviews carried out for outdoor installations to identify and address ergonomic issues. Access to valves and sampling points included during HFE screening.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
1. Implement all HFE DEPs standards required and follow all remedial actions stated in Human Factors Engineering Screening report issued in June 2016
1
![Page 17: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/17.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Infectious and venomous animal bites
RAM: Medium
Acute Potential Health Effects
Severe wounds, tetanus, rabies, poisoning, acute renal failure and anaphylactic shock only for snakes RAM: 4B
Chronic Potential Health Effects
None known RAM:
Scenario During outdoor activities Route & Form of Exposure
Dermal
Frequency & Duration of Exposure
Exposure Limit
Exposure Rating & Justification
ALARP Status Yes ALARP Justification No cases (prevalence) in last 6 years. Controls in place
Controls Effectiveness
Written procedure/safe work practice - Written site procedure discourages unauthorized night outing to minimize chance-meeting of reptiles.
Personal bite prevention - Workers are discouraged from night-time outings when reptiles are known to be more active.
Vector control measures - Periodic fumigation PPE-Skin protection: gloves, clothing - Safety booth provided, which minimizes exposed body parts.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 18: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/18.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Insect, spiders, scorpions, bees
RAM: Medium
Acute Potential Health Effects
Irritation, inflammation, poisoning, anaphylactic shock RAM: 2D
Chronic Potential Health Effects
Allergic reaction, secondary infection, RAM: 3C
Scenario During outdoors activities Route & Form of Exposure
Dermal
Frequency & Duration of Exposure
Exposure Limit
Exposure Rating & Justification
ALARP Status Yes ALARP Justification No cases (prevalence) in last 6 years. Controls in place
Controls Effectiveness
Written procedure/safe work practice Personal bite prevention Vector control measures - Periodic fumigation Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 19: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/19.jpg)
Work Area/Job SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Legionella bacteria (waterborne)
RAM: Medium
Acute Potential Health Effects
Pontiac fever (mildest form of infection); Legionnaires' disease - pneumonia (severest form of infection - may be fatal) RAM: 4B
Chronic Potential Health Effects
Effects on lung function RAM: 3B
Scenario All staff (on plot and off plot) has the potential to be exposed to the following Legionella sources: showers/ aerolized water, water from fire water systems, potable water, any scenario where ambient temperature water may become airborne and inhaled.
Route & Form of Exposure
Inhalation Aerosol
Frequency & Duration of Exposure
Exposure Limit PDO Action Level: 100 cfu/ml
Exposure Rating & Justification
ALARP Status NO
ALARP Justification Design verification of controls
Controls Effectiveness
Written procedure/safe work practice - PDO Legionella management procedure is in place, ready for implementation. The procedure requires that water systems and equipment that are a potential source of Legionella is identified, documented, assessed and a monitoring and control program defined.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
1. Review information about fire water design regarding aerosols, dead legs and stagnant water according to PDO PR-2109.
2
![Page 20: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/20.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Heat Stress / Hot Temperature Differentials
RAM: Medium
Acute Potential Health Effects
Heat stroke leading to death (lesser symptoms: exhaustion, cramps, rash, fatigue) RAM: 4B
Chronic Potential Health Effects
Dermatitis RAM: 2C
Scenario Working with BA (breathing apparatus) and confined space entry work presents an additional risk factor due to the increased metabolic rate due to PPE load.
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit PDO SP 1231
Exposure Rating & Justification
ALARP Status Yes ALARP Justification Controls in place Controls Effectiveness
Process design/equipment standards - Design makes provision for separate resting areas with AC and fresh, cool water supply
Fitness to Work - Medical fitness to work standards has been established for users of BA sets.
Training and information on hazard - Processes and procedures in place for effective supervision.
Administrative controls, such as area restrictions and limited schedules - Provisions made for shaded areas and cool drinking water. Offices with AC are available on plot, for example the Central Control Room.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 21: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/21.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Ultra violet light (UV) - wavelength 100 - 400 nm (non-ionizing radiation)
RAM: Medium
Acute Potential Health Effects
Skin burns, erythema (reddening of the skin) and darkening of the skin. Photokeratitis (painful condition caused by the inflammation of the cornea of the eye). Conjunctivitis (inflammation of the conjunctiva) . Eye disorders with pain and discomfort ("flash burn", "arc eye") RAM: 2C
Chronic Potential Health Effects
IARC 1 - Human carcinogen (skin cancer). Skin aging. May cause pterygium, cataracts and macular degeneration RAM: 4B
Scenario All staff is partially exposed to direct sun in hot/humidity weather
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit See ACGIH last version
Exposure Rating & Justification
ALARP Status Yes
ALARP Justification Controls in place
Controls Effectiveness
Process design/equipment standards - Plant layout makes provision for sheltered areas to provide relief from sun exposures.
Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
![Page 22: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/22.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Noise
RAM: Medium
Acute Potential Health Effects
Loud steady noise: temporary threshold shift. Impact noise: rupture of eardrum; acoustic trauma. RAM: 2C
Chronic Potential Health Effects
Noise induced hearing loss (permanent threshold shift); tinnitus (ringing in ears) RAM: 2D
Scenario All staff working on process facilities have the potential for exposure to plant noise and equipment (transfer pumps).
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit 85 dB(A)
Exposure Rating & Justification
ALARP Status NO
ALARP Justification Verification of controls
Controls Effectiveness
Process design/equipment standards - Equipment sourced for emissions no greater than 85dB(A)
Recovery Measures Effectiveness
Event-based: IH monitoring - Noise mapping during commission - Company hearing conservation plan implemented for areas exceeding 85dB(A).
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
1. Ask vendor for SPL output pumps characteristic. 2. Ensure that separation distance between pumps is in compliance with PDO
SP-1127.
1
![Page 23: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/23.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Visible light (illumination - too much; too little) - wavelength 400 - 780 nm
(non-ionizing radiation)
RAM: Low
Acute Potential Health Effects
Eyestrain, headaches, decreased efficiency, increase in work errors. RAM: 1C
Chronic Potential Health Effects
None known RAM:
Scenario All staff are potentially exposed to insufficient lighting and poor night time illumination of the plant and facilities.
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit ACGIH Last Version
Exposure Rating & Justification
ALARP Status NO
ALARP Justification Verification of controls
Controls Effectiveness
Process design/equipment standards - HFE screening completed to assess if a detailed survey was required.
Local Control - CCTV to reduce operator frequency of walkabout. Recovery Measures Effectiveness
Medical Facilities in place, First Aid, Medical Emergency Response Plan
Remedial Actions Priority
1. Process design/equipment standards - Confirm design in accordance with HFE DEP’s and FEED Emergency lightning guideline (GU/705).
3
![Page 24: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/24.jpg)
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Hazard Psychological Hazards and Stress
RAM: High
Acute Potential Health Effects
Stress symptoms like headaches, high blood pressure, sleep disturbance, irritability, Chest pain, Difficulty breathing, Severe pain, Symptoms of shock (shallow breathing, rapid or weak pulse, nausea, shivering, pale and moist skin, mental confusion, and dilated pupils), Fatigue, Nausea/vomiting, Dizziness, Profuse sweating, Thirst, Visual difficulties, Clenching of jaw, Nonspecific aches and pains RAM: 2D
Chronic Potential Health Effects
Anxiety, depression, severe gastrointestinal symptoms, heart attack RAM: 4D
Scenario All staff (on and off plot) have the potential to experience isolation from family and friends, especially those on rotational duty; working on dead-lines, pressure owning to the nature of the work environment is inherent.
Route & Form of Exposure
Frequency & Duration of Exposure
Exposure Limit
Exposure Rating & Justification
ALARP Status Yes ALARP Justification Projects Controls in place, Stress control program to be implemented once
operation Phase starts Controls Effectiveness
Stress - generic organizational controls - Clear organizational structure with adequate human resources.
Local Control - Good camp, welfare and sport facilities. No overcrowding in facilities or in accommodations.
Recovery Measures Effectiveness
Stress - generic recovery measures - Employee assistance program (call centre during office hours).
Remedial Actions Priority
![Page 25: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/25.jpg)
5. Generic Controls, Recovery Measures and Remedial Actions
Work Area SNGP/KGP FIREWATER NETWORK PROJECT
Controls Effectiveness
Regulations, standards, specifications and procedures to be applied to the project To be reviewed
Plant layout, bunding and drainage
Implement area isolation
Use standardized equipment and conventional technology To be reviewed
Energy efficiency in equipment & technology
Incorporate Lessons learned
Have experienced resources
Automation of the facilities
Proper training
Recovery Measures Effectiveness
Safety Showers and eye wash To be reviewed
Recovery from hazardous events, fire & gas detection, fire response, ESD, blowdown, escape and evacuation
Remedial Actions Priority
CONTROLS: 1. Site verification is required to finalize the effectiveness of controls,
recovery measures and final ALARP conditions mentioned in this HRA.
1
RECOVERY MEASURES: 1. Emergency / safety showers: Select safety showers/eye wash stations that
have the capability to cool water during summer period.
1
![Page 26: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/26.jpg)
6. Control statements for Low RAM Hazards
Work Area/Job Hazard CONTROLS NEED IMPROVEMENT? MORE DETAILED ASSESSMENT?
SNGP/KGP FIREWATER
NETWORK PROJECT
Particulates (total, not classified)
No
Man made or synthetic vitreous fibers (MMF)
No
Biocides No
Lubricating Oils, C16-C35 Hydrocarbons (includes oil mist and glycerin), Greases (< 3%PCAH Content), dielectric oils and Hydraulic and heat transfer fluids
No
Fire foam No
Fungus/mold growth, or bioaerosols
No
Indoor climate No
Visible light (illumination - too much; too little) - wavelength 400 - 780 nm (non-ionizing radiation)
Yes, see detailed appraisal
Extremely Low Frequency magnetic radiation (ELF) - wavelength: > 30 km (non-ionizing radiation)
No
Radiowave/Microwave radiation - wavelength 1 mm - 30 km (non-ionizing radiation)
No
![Page 27: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/27.jpg)
Appendix 1: Definitions Acute Health Effect Health Effect that occurs immediately or a short time (seconds to hours) following exposure, such as heat stroke, chemical burns and asphyxiation. Agent See Hazard ALARP - As Low As Reasonably Practicable The point at which the cost (in time, money and effort) of further Risk reduction is grossly disproportionate to the Risk reduction achieved. Barrier A Risk Control or a Recovery Measure. Barriers provide the means of preventing an Event or Incident, or of mitigating the Consequences. A Barrier can be an item of equipment or a human intervention, and can also be a Control on an Escalation Factor. Chronic Health Effect Health Effect that occurs gradually over a long period of time (months or years), generally following repeated and prolonged exposure. In specific cases a short term exposure may result in a chronic health effect. Consequence An Effect on people, assets, the environment or reputation as a result of a Hazard being released. Control A means of preventing an Incident. Controls can be engineering, procedural or behavioural. Critical Activity An activity necessary for the development, implementation or maintenance of a Barrier established for managing Hazards with RAM red Risks. Effect The Consequence of the release of a Hazard. Escalation Factor A situation, condition or circumstance that may lead to the partial or full failure of a Barrier. Event An Incident that occurs when a Hazard is released. Exposure Limit The airborne concentration of chemical agents and levels of physical agents to which nearly all workers may be repeatedly exposed day after day without adverse Effect. Exposure Rating The chance of over-exposure to a health hazard when compared against agreed control standards. The exposure rating is evaluated as Very Low, Low, Medium or High. Hazard An agent with the potential to cause harm to people, damage to Assets, or an Impact on the environment or reputation. Health Hazard A factor of a physical, chemical, biological, ergonomic or psychological nature with the potential to cause harm to the health of people. HRA - Health Risk Assessment
![Page 28: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/28.jpg)
A process of identifying, evaluating, controlling and managing Health Risks, associated with work to prevent acute and chronic health Effects. Incident An unplanned Event or chain of Events that has, or could have, resulted in injury or illness or damage to Assets, the environment or reputation. Likelihood The probability that a specified Consequence will happen. OEL – Occupational Exposure Limit The airborne concentration of chemical agents and levels of physical agents to which nearly all workers may be repeatedly exposed day after day without adverse effect. RAM - Risk Assessment Matrix A tool used to assess the Consequences and Risks of Hazards to HSSE. The results are referred to as a RAM Severity rating and a RAM Risk rating. Recovery Measure A Barrier that reduces the Consequences of the release of a Hazard as a result of an Incident. Recovery Measures can be engineering, procedural or behavioural measures. Remedial Action Plan RAP - A Plan to implement corrective action items. Risk The combination of the Consequence of a specific Hazard being released and the Likelihood of it happening. Risk Assessment The process of identifying the Consequences of the Worst Case Credible Scenario arising from the release of a Hazard, and estimating the Likelihood of that scenario. Severity A level of Consequence on the RAM on a scale of 0 to 5. TBD To be determined.
![Page 29: Petroleum Development Oman L.L.C. SNGP/KGP …...The scope of this project is to design and install the Firewater System for both SNGP and KGP on-plot facilities in accordance to SP-1075](https://reader034.vdocument.in/reader034/viewer/2022042711/5f80eccd6516ec5b492952f5/html5/thumbnails/29.jpg)
Appendix 2: Risk Assessment Matrix