Philip Harris Electric- Dipole Moment Searches * (mainly neutron) * • Room-temperature nEDM expt: latest results • CryoEDM: upcoming, 100x sensitivity • Other EDM expts

Upload: patricia-james

Post on 21-Jan-2016

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

Philip Harris

Electric-DipoleMoment Searches

*(mainly neutron)

*

• Room-temperature nEDM expt: latest results• CryoEDM: upcoming, 100x sensitivity• Other EDM expts

Page 2: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Electric Dipole Moments

EDMs are P odd T odd

Complementary approachto study of CPv; probenew physics

SM predictions v. small; othermodels typ. 106 larger...

E +

dn = dn s

Page 3: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Generating EDMs

E.g. in SUSY:

Assumptions: gg’, sin()1, 200 GeVGives u, d quark EDMs 3x10-24 ecm 100 x current limit

“SUSY CP” problem

q q

gaugino

squarkcouplingconst g g’ei

Page 4: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Constraints on SUSY parameters

Pospelov & Ritz, hep-ph/0504231

MSUSY = 500 GeVtan = 3

Page 5: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

SUSY, cont’d

Lebedev et al., hep-ph/0402023

Page 6: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Measurement principle

() – () = – 4 E d/ h

assuming B unchanged when E is reversed.

B0 E<Sz> = + h/2

<Sz> = - h/2

h(0) h() h()

B0 B0 E

Level splitting we can resolve:<10-21 eV

Use (Ramsey) NMR on ultracold neutrons in B, E fields

Page 7: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Apparatus

N S

Magnetic shielding

Storage cell

Magnet & polarizing foil Ultracold

neutrons(UCN)

UCN detector

Approx scale 1 m

Magnetic field coil

B

High voltage lead

E

/analysingfoil

Page 8: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Apparatus

Neutronstoragechamber

HVfeedthru

B-fieldcoils

Page 9: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

0 5 10 15 20 2529.9260

29.9265

29.9270

29.9275

29.9280

29.9285

29.9290

29.9295

Neu

tron

res

onan

t fr

eque

ncy

(Hz)

Run duration (hours)

nEDM measurement Keep track of neutron resonant frequency Look for n freq changes correlated with changes

in E

Electric Field

+-

ndE

Page 10: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

0 5 10 15 20

7.7882

7.7884

7.7886

7.7888

7.7890

Run duration (hours)

Mer

cury

freq

uenc

y (H

z)

Mercury co-magnetometer

Compensates B drift...

Page 11: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 20060 5 10 15 20 25

29.9260

29.9265

29.9270

29.9275

29.9280

29.9285

29.9290

B = 10 -10 T

Raw neutron frequencyCorrected frequency

Pre

cess

ion

freq

uenc

y (H

z)

Run duration (hours)

nEDM measurement

29.9295

Page 12: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

New systematic

rBz

Br

and, from Special Relativity, extra motion-induced field

2

1

c

EvB

Two effects:

Page 13: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Geometric Phase

Br

Br

Bnet

Bnet

Bv

Bv

Bv

Bnet

Bnet

... so particlesees additionalrotating field

Frequency shift E

Looks likean EDM

Bottle(top view)

J. Pendlebury et al., PRA 70 032102 (2004)P. Harris, J. Pendlebury, PRA 73 014101 (2006)

Unique signature:can eliminate it

Page 14: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Effect Shift UncertaintyStatistical 0 1.51Door cavity dipole; quadrupole fields

-1.10 0.45

Other GP dipole shifts 0 0.60(E x v)/c2 from translation 0 0.05(E x v)/c2 from rotation 0 0.10Light shift: direct & GP 0.35 0.08B fluctuations 0 0.24E forces – distortion of bottle 0 0.04Tangential leakage currents 0 0.01AC B fields from HV ripple 0 0.001Hg atom EDM 0 0.052nd order Exv 0 0.002

Total –0.75 1.51 stat, 0.80 sys

Error budget (10-26 e.cm)

Page 15: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Final Result

New limit:|dn| < 3.0 x 10-26 e.cm (90% CL)

(prev. limit 6.3 x 10-26 e.cm, PRL 82, 904 (1999))

Preprint hep-ex/0602020provisional acceptance PRL

www.neutronedm.org

Page 16: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

2. CryoEDM

100-fold improvement in sensitivity!

n = 8.9 Å; E = 1.03 meV

Landau-Feynman dispersion curve for 4He excitations

Dispersion curve for free neutrons

R. Golub and J.M. Pendlebury Phys. Lett. 53A (1975), Phys. Lett. 62A (1977)

•More neutrons•Higher E field•Better polarisation•Longer coherence time

Page 17: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

CryoEDM overviewNeutron beam input

Transfer section

Cryogenic Ramsey chamber

Page 18: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Cryogenic Ramsey chamber

Superfluid He

HV electrode

n storage cells(eventually 4)

HV feed

Page 19: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

CryoEDM

Turns onOctober 2006

Page 20: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

3. Other EDM experiments: PSI

spallation target D2O moderator currently testing

apparatus from ILL

Page 21: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Other nEDM experiments: USA

SNS at ORNL

• LANL-led• testing underway• not yet funded

Page 22: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Electron EDM: Berkeley

Final result:de<1.6 x 10-27 e.cm(systematics limited)

Use unpaired e-

in paramagnetic atom

Pairs of Tl beams in opposite E fields

Na beams as comagnetometer

Up beam

E field

B field

Statepreparationlaser

Stateanalyser laser Down beam

Page 23: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Electron EDM measurements

Group System Advantages Projected gain

D. Weiss (Penn St.) Trapped Cs Long coherence ~100!

D. Heinzen (Texas) Trapped Cs Long coherence ~100!

H. Gould (LBL) Cs fountain Long coherence ?

L. Hunter (Amherst) GdIG solid Huge S/N 100?

S. Lamoreaux (LANL)C.-Y. Liu (Indiana)

GGG solid Huge S/N 100?-100,000?

E. Hinds (Imperial) YbF beam Large Internal E 3, then 30

D. DeMille (Yale) PbO* cell Int.E+good S/N 30-1,000?

E. Cornell (JILA) trapped HBr+ Int. E + long T ??

N. Shafer-Ray (Okla.) trapped PbF Int. E + long T ??

(This slide mainly from DeMille, PANIC ’05)

Page 24: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

pump laser

detectionlaser

PMT

statesplitter

staterecombiner

Imperial College Electron EDM experiment

Pulsed supersonic YbF beam source

E B

Molecule interferometer

pulsed YAG laser

Yb target

Ar+SF6

skimmer

J.J.Hudson, B.E. Sauer, M.R. Tarbutt, & E.A. Hinds,

PRL. 89, 023003 (2002).

• Now taking data• Studying systematics• Results soon

Page 25: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

199Hg EDM

Optically pumped 199Hg atoms precess in B, E fields, modulating absorption signal

Dual cells remove effect of drifts in B

Result: d(199Hg) < 2.1 x 10-28 e cm

Provides good limit on CPv effects in nuclear forces, inc. QCD

Page 26: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

... and more!

Muon EDM: from g-2 (7E-19; proposal at JPARC for ~10-24)

Deuterium EDM: similarprinciple (may reach ~10-29 e.cm)

Tau weak dipole moment – look for CP-odd observables in diff. x-sec at Z res.(6E-18 e.cm from LEP data)

Sensitivity to physics BSM depends on source of CPv

Page 27: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

-150

-100

-50

0

50

100

150

-10 0 10 20 30 40

R-1 (ppm)

EDM

(10

-26

e.c

m)

Conclusions

New nEDM limit, 3.0 x 10-26 e.cm Tightens the constraints on beyond-SM CPv

Systematics understood as never before CryoEDM coming soon – 100x more

sensitive Several new measurements starting up Watch this space!

-150

-100

-50

0

50

100

150

-40 -20 0 20 40

R-1 (ppm)

ED

M (

10-2

5 e

.cm

)

-10

-8

-6

-4

-2

0

2

4

6

8

10

500 700 900 1100 1300 1500 1700 1900 2100

ED

M (

10-2

5 e.c

m)

Page 28: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

spare slides

Page 29: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Cryogenic Ramsey chamber

Superfluid He

HV electrode

n storage cells

Page 30: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Ramsey method of Separated Oscillating Fields

4.

3.

2.

1.

Free precession...

Apply /2 spinflip pulse...

“Spin up” neutron...

Second /2 spinflip pulse.

Page 31: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Ramsey resonance “2-slit” interference pattern Phase gives freq offset from resonance

29.7 29.8 29.9 30.0 30.1

10000

12000

14000

16000

18000

20000

22000

24000

xx

x = working pointsResonant freq.

xx

Spi

n-U

p N

eutr

on C

ount

s

Applied Frequency (Hz)

Page 32: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

nEDM apparatus

N S

Four-layer mu-metal shield High voltage leadQuartz insulating cylinder

Coil for 10 mG magnetic field

Upper electrodeMain storage cell

Hg u.v. lamp

PMT to detect Hg u.v. lightVacuum

wallMercury

prepolarising cell

Hg u.v. lampRF coil to flip spins

Magnet

UCN polarising foil

UCN guide changeover

Ultracold neutrons

(UCN)

UCN detector

Page 33: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Neutron EDM results (binned)

-10

-8

-6

-4

-2

0

2

4

6

8

10

500 700 900 1100 1300 1500 1700 1900 2100

ED

M (

10-2

5 e.c

m)

Stat. limit now 1.51 x 10-26 e.cm

Page 34: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Neutron EDM results (individual runs)

-50

-40

-30

-20

-10

0

10

20

30

40

50

1

18

35

52

69

86

10

3

12

0

13

7

15

4

17

1

18

8

20

5

22

2

23

9

25

6

27

3

29

0

30

7

32

4

34

1

35

8

37

5

39

2

40

9

42

6

44

3

46

0

47

7

49

4

51

1

52

8

54

5

56

2

57

9

59

6

61

3

63

0

64

7

66

4

68

1

69

8

ED

M (

10-2

5 e.c

m)

What’s going on here,for example?

Page 35: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Geometric Phase How to measure it

Consider

Should have value 1 R is shifted by magnetic field

gradients Plot EDM vs measured R-1:

n

Hg

Hg

nR

Page 36: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Geometric Phase

-150

-100

-50

0

50

100

150

-40 -20 0 20 40

R-1 (ppm)

ED

M (

10-2

5 e.c

m)

Magnetic field down

z

B

Page 37: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Geometric Phase

-150

-100

-50

0

50

100

150

-10 0 10 20 30 40

R-1 (ppm)

ED

M (

10

-26 e

.cm

)

Magnetic field up

z

B

Page 38: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Results

R-1

EDM

0

B down

B up The answer?

Nearly...

-150

-100

-50

0

50

100

150

-40 -20 0 20 40

R-1 (ppm)

ED

M (1

0-2

5 e

.cm

)

-150

-100

-50

0

50

100

150

-10 0 10 20 30 40

R-1 (ppm)

EDM

(10

-26

e.c

m)

Page 39: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Results

R-1

EDM

0

Small dipole/quadrupole fields can pull lines apart

& add GP shiftsB up

B down

Page 40: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Results

R-1

EDM

0

Small dipole/quadrupole fields can pull lines apart

& add GP shiftsB up

B down

Measure and apply correction

...difficult!

Page 41: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

History

Factor 10every 8 yearson average

Now

CryoEDM

Page 42: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

Other nEDM experiments: Mainz

Testing UCN source at TRIGA, Mainz for later installation at FRM, Munich

Reactor channel

Neutronvalve

UCN guide tubeDeuterium converterin in-pile cryostat

Neutron storage volume

Test cryostat

Reactor channel

Neutronvalve

UCN guide tubeDeuterium converterin in-pile cryostat

Neutron storage volume

Test cryostat

Page 43: Philip Harris Electric-Dipole Moment Searches * (mainly neutron) * Room-temperature nEDM expt: latest results CryoEDM: upcoming, 100x sensitivity Other

P. HarrisBEACH 2006

EDM given by fringe shiftwith reversal of E or B

Magnetic field (nT)

Fluorescence signalThe interference fringes

Data being taken now. Systematics being studied.

de = _ ± 5 x 10-28 e.cmCurrent status:

de = _ ± 5 x 10-29 e.cmExpected 2010: