phillystran hptg-i aramid fiber guying · pdf filephillystran hptg-i aramid fiber guying...
TRANSCRIPT
PHILLYSTRAN HPTG-I ARAMID FIBERGUYING SYSTEMS FOR BROADCASTTOWERS AND ANTENNASPhillystran High Performance Tower Guys (HPTG-I) aramid fiber guying systems
are the results of many years of experience with AM, FM, TV and communications
towers up to 2,000 feet high, operating at powers as high as 2 megawatts. HPTG-I
is in use in every climate from the deserts of Saudi Arabia to the tundra regions
of Greenland. Phillystran HPTG-I guy assemblies are installed atop 1 World Trade
Center (Freedom Tower) to support the 400 ft mast. That structure is the tallest
in the Western Hemisphere and will be home to a wide variety of broadcast and
communications antennas serving the great New York City area.
HTPG-I aramid fiber guying systems eliminate problems associated with EHS(2) and BS(2) steel guy cables such as:
• ElectroMagnetic Interference (EMI)• Radio Frequency Interference (RFI)• Signal Suppression• Array Directional Irregularities• Zapping and White-Noise Arcing (associated with ceramic insulators)
WHAT IS A “GUYING SYSTEM?”
Phillystran’s HPTG-I aramid fiber guy lines are one component of the HPTG-I Guying System. By offering a system, the user is assured that all details related to the HPTG-I guy line have been addressed. This is the unique factor which differentiates these products from other steel guy alternatives.
TABLE OF CONTENTS:How to determine what size is required - Pg. 2What are Corona Sockets and when are they required? - Pg. 3What is the purpose of the HPTG-I jacket? - Pg. 4Engineering Design Data - Pg. 4Jacketing compound properties - Pg. 4Tensioning Procedure - Pg. 5When are vibration dampers required? - Pg. 5Phillystran PLP big grip dead-ends for tower guy systems - Pgs. 6-8
HOW TO DETERMINE WHAT SIZE HPTG-I IS REQUIREDA certified structural engineer should be consulted to determine guy size.
Total Guying where the HPTG-I assembly is greater than 50% of
the total guy length: Select the HPTG-I size equal to the EHS steel
guy size (recommended by either a structural engineer or tower
manufacturer) based on RBS or refer to TIA-222-G column in
Table 1.
Partial Guying where the HPTG-I assembly is 50% or less of the
total guy length: Partial guys of HPTG-I should not be less than
10% of the tower height (at the HPTG-I assembly attaching point)
in length and should extend equally in all directions at a given
guy level. Example is a 3-sided 1,000 ft. FM tower with 3 top level
HPTG-I assemblies not less than 100 ft. in length. Refer to TIA-
222-G column in Table 1.
HIGH PERFORMANCE TOWER GUY (HPTG-I) SIZE SELECTION CHART
HPTG-I P/N
and RBS(1)
EHS/BS EQUIVALENT (2)
(IN)
TIA-222-G EQUIVALENT
(IN)
JACKETED DIAMETER
(IN)
JACKETED WEIGHT
(LB/1000 FT)
CORONA SOCKET
P/NBIG GRIP
P/N
SVD OR AFS VIBRATION DAMPERS
HPTG 1200I — — 0.17 11 — — —
HPTG 2100I 1/8 EHS — 0.22 18 — PLP-2738 SVD 0103
HPTG 4000I 3/16 — 0.30 33 — PLP-2739 SVD 0103
HPTG 6700I 1/4 — 0.37 50 CS 15400 PLP-2755 SVD 0103
HPTG 11200I 5/16 1/4 EHS 0.44 70 CS 15400 PLP-2558 SVD 0104
HPTG 15400I 3/8 5/16 0.51 95 CS 15400 PLP-2756 SVD 0105
HPTG 20800I 7/16 3/8 0.57 115 CS 35000 PLP-2763 SVD 0106
HPTG 27000I 1/2 7/16 0.65 150 CS 35000 PLP-2765 SVD 0106
HPTG 35000I 9/16 1/2 0.69 170 CS 35000 — SVD 0106
HPTG 42400I 5/8 9/16 0.84 230 CS 42400 — AFS 5058104
HPTG 58300I 3/4 5/8 0.96 300 CS 58300 — AFS 5058105
HPTG 85000I 7/8 11/16, 3/4 BS 1.14 420 CS 85000 — AFS 50589317
HPTG 130000I 1 BS 7/8 1.15 740 CS 130000 — CONTACT PHILLYSTRAN
HPTG 160000I 1-1/16 1 1.76 910 CS 200000 — CONTACT PHILLYSTRAN
HPTG 200000I 1-1/4 1-1/16, 1-3/16 1.87 1,050 CS 200000 — CONTACT PHILLYSTRAN
HPTG 252000I 1-3/8 1-1/4 2.08 1,290 CS 252000 — CONTACT PHILLYSTRAN
(1) HPTG-I part number = the Rated Break Strength (RBS) in lbs.(2) Extra High Strength (EHS)/Bridge Strand (BS) steel guys based on Rated Break Strength (RBS)
Table 1
2
WHAT ARE CORONA SOCKETS AND WHEN ARE THEY REQUIRED?
Corona sockets are aluminum, resin-filled, potted end terminations and are factory installed. Phillystran recommends these potted end terminations for all commercial AM, FM and TV projects. Designed to protect HPTG-I from RF burning, Corona Sockets are the first level of protection for HPTG-I products, with additional levels of protection required for high powered broadcasting stations. Contact Phillystran for recommendations above 10 kw.
See Table 2 for Corona Socket dimensions.
CORONA SIZE
DIMENSIONS IN INCHES
A B C D E F GPIN DIA
WT (LB)
CS 42400 14.87 3.75 1.22 4.75 0.79 2.12 10.87 1.12 11
CS 58300 17.62 4.62 1.47 4.87 1.00 2.50 13.00 1.37 18
CS 85000 20.00 5.31 1.93 5.12 1.25 2.87 14.62 1.50 25
CS 130000 25.00 7.50 2.75 7.87 1.53 4.37 16.68 2.50 68
CS 200000 27.00 7.93 2.75 9.25 2.00 4.43 18.78 2.50 85
CS 252000 31.50 9.06 2.75 9.87 2.25 4.43 23.25 2.50 115
CORONA SIZE
DIMENSIONS IN INCHES
A B C D E F GPIN DIA
WT (LB)
CS 15400 10.00 2.37 .93 2.93 .47 1.68 7.12 .75 3
CS 35000 14.12 3.40 1.05 4.12 .75 2.50 10.00 1.12 8
F
C
A
14.781
1.781
� 1.188
REVZONE
REVISIONS
DESCRIPTION DATE APPROVED
DRAWN
CHECKED
QA
MFG
APPROVED
DATE
SIZE FSCM NO. DWG NO. REV
SCALE
ASHEET
X-08H13-3
GJD 08/13/2008 CORONA SOCKET FOR HPTG(I) 42400
PHILLYSTRAN, INC.151 COMMERCE DRIVEMONTGOMERYVILLE, PA 18936
A
1 OF 1
G
D E B
Table 2
F
C
A
G
D E B
3
WHAT IS THE PURPOSE OF THE HPTG-I JACKET?
The aramid fiber guy line core must be protected from the harmful effects of ultraviolet (UV) radiation. The HPTG-I thick extruded jacket is a co-polymer polyurethane with excellent weathering and dielectric properties, blended with carbon black pigmentation for maximum UV resistance. The outer jacket sheds moisture thus assuring consistent dielectric properties regardless of the season or climate.
What is the life expectancy of HPTG-I?
HPTG-I differs from other non-metallic guy lines or rods because of the thick protective outer polyurethane extruded jacket (see Table 3) which protects the HPTG-I for many years.
Phillystran guy line systems have been in place since the early 1970s, with an expected life of 25 years or more; perhaps the life of the tower(s). Retirement criteria is based on the condition of the jacket, especially near the base of the corona socket. It is recommended that HPTG-I guy systems be inspected at least annually, and more frequently as the guy system ages.
HPTG-I POLYURETHANE JACKETING COMPOUND
TYPICAL VALUES
ASTM SAMPLE*SI UNITS USCS
UNITS
Shore Hardness D 2240 2 42 D 42 D
Tensile Strength D 412 1 38.2 MPa 5550 psi
Tensile Stress @ 100% Elongation D 412 1 9.0 MPa 1300 psi
Tensile Stress @ 300% Elongation D 412 1 17.2 MPa 2500 psi
Ultimate Elongation D 412 1 525% 525 %
Tensile Set @ 200% Elongation D 412 1 25% 25%
Vicat Softening Point D 1525 2 110 deg. C
230 deg. F
Compression Set D 395
22 Hrs. @ 23 degree Centigrade 2 25% 25%
22 Hrs. @ 70 degree Centigrade 2 60% 60%
Glass Transition Temp. DSC** 3 -44 deg. C -47 deg. F
Tear Resistance D 624 Die C 2 74.4 kN/m
425 lb/in
Tear Resistance D 470 1 23.6 kN/m
135 lb/in
Specific Gravity D 792 2 1.13 1.13
Low Temperature Stiffness D 1053
Modulus of Rigidity @ 23 deg.C 2 11.1 MPa 1609 psi
Modulus of Rigidity @ 0 deg.C 2 17.2 MPa 2500 psi
Modulus of Rigidity @ -20 deg.C 2 55 MPa 8000 psi
Modulus of Rigidity @ -40 deg.C 2 331 MPa 28000 psi
* (1) 25 mil, extruded (2) 75 mil, milled and pressed (3) granules
** Different Scanning Calorimeter, 10 degree C/min. temperature program
Table 3
HIGH PERFORMANCE TOWER GUY (HPTG-I) ENGINEERING DESIGN DATA
PART NUMBER
LOAD BEARING AREA
(SQUARE INCHES)
NOMINAL TENSILE MODULUS
(MILLION psi)
10TH CYCLE EA (POUNDS)
1ST CYCLE
10TH CYCLE
HPTG 4000I 0.0168 14 15 252,000
HPTG 6700I 0.0280 14 15 421,000
HPTG 11200I 0.0467 14 15 701,000
HPTG 15400I 0.0609 14 15 913,000
HPTG 20800I 0.0862 14 15 1,290,000
HPTG 27000I 0.112 14 15 1,670,000
HPTG 35000I 0.142 14 15 2,130,000
HPTG 42400I 0.188 10.5 12 2,250,000
HPTG 58300I 0.247 10.5 12 2,960,000
HPTG 85000I 0.366 10.5 12 4,390,000
HPTG 130000I 0.675 10.5 12 8,100,000
HPTG 160000I 0.870 10.5 12 10,400,000
HPTG 200000I 1.03 10.5 12 12,400,000
HPTG 252000I 1.31 10.5 12 15,800,000
4
WHEN ARE VIBRATION DAMPERS REQUIRED?
Guy lines, whether steel or non-metallic, may exhibit aeolian (high frequency) or galloping (low frequency) vibration. HPTG-I is effectively dampened using Preform Line Products’ Spiral Vibration Dampers (SVD) or Air Flow Spoilers (AFS); see Table 1. The SVDs are installed in pairs with one pair installed within 6 inches of each end of the HPTG-I Corona Socket, using four AFSs per assembly. Vibration dampers are recommended for any HPTG-I assemblies greater than 100 ft. in length, and greater than 50% of the total guy length.
What is the function of the steel tail?
A steel tail is a length of EHS steel guy line connecting the HPTG-I assemblies to the turnbuckle or guy anchor, The steel tail protects the HPTG-I assemblies from damage due to brush fires, lawn maintenance equipment or vandals. The steel tail length should be sufficient to get the bottom end of the HPTG-I assembly above arm reach, or above brush tops (if located in a marsh or tall brush area). The HPTG-I should never pass through tree limbs or be allowed to rub against poles or trees. The steel tail allows for easier guy length calculations and serves as a guy tension monitoring point, as well as a safer area to attach guy grips during guy line installation and tensioning.
Grounding of Tower and Anchors
Grounding will decrease the chances of damage to the HPTG-I caused by RF flashover or lightning. Improper grounding can expose the guy system to damage at both the tower attaching point, as well as at the bottom end connection (where the HPTG-I attaches to the steel tail). Most Electrical and Broadcasting Consultants can advise on proper grounding techniques.
TENSIONING PROCEDURE FOR HPTG-I
It is important that the plumb of the tower be maintained throughout this procedure. Example: Tension HPTG-I assemblies to approximately 15% of its RBS. Guy tension will relax to approximately 10% RBS. Consult a tower
structural engineer before tensioning HPTG-I assemblies.
5
• Grip designed to match rope twist direction
• Special sized wires for ease of application
• Galvanized steel and “C” coat construction
• Color coded for ease of identification
• Longer length to match Phillystran’s high performance
• Designed to develop the rated strength of the Phillystran products
PHILLYSTRAN PLP BIG GRIP DEAD-ENDS FOR TOWER GUY SYSTEMS
COLOR CODED CROSS-OVER MARKS
IDENTIFICATION TAPE PITCH LENGTH
LONG LEG
SHORT LEG
COLOR CODE
PHILLYSTRAN BIG GRIP P/N HPTG-I P/N
BIG GRIP LENGTH (IN)
BIG GRIP WEIGHT (LB)
BIG GRIP COLOR CODE
RECOMMENDED HEAVY DUTY THIMBLE (IN)
PLP-2738 HPTG 2100I 31.0 0.53 Blue 3/8
PLP-2739 HPTG 4000I 37.5 0.87 Yellow 7/16
PLP-2755 HPTG 6700I 45.5 1.26 Red 1/2
PLP-2558 HPTG 11200I 51.0 1.65 Black 1/2
PLP-2756 HPTG 15400I 59.5 2.72 Yellow 5/8
PLP-2763 HPTG 20800I 66.0 3.04 Red 3/4
PLP-2765 HPTG 27000I 76.0 4.02 Green 7/8
Weights and Dimensions can vary.
Phillystran Big Grip Dead-Ends’ unique features include:
Color Coded Cross-over Marks: Indicate starting point for application.
6
INSTALLATION PROCEDURE• Pretension the guy for easier Big
Grip installation.
• Insert thimble into eye of Big Grip following “Installation Guidelines”. Install Big Grip with thimble through attaching hardware. Begin the installation for the grip at the cross-over marks (Figure 1).
• Wrap on the first leg (either leg) with two complete wraps. Align the cross-over marks, then wrap the second leg with two complete wraps, ending opposite the first leg.
• Complete the installation by wrapping both legs simultaneously (keeping legs opposite each other) or alternating legs half a wrap at a time. (Figure 2).
NOTE: DO NOT completely wrap one leg at a time as is common with steel guy strand. The second leg will not install properly due to HPTG-I rope distortion.
• It may be necessary to split a leg to complete installation of the grip. Be sure that all wire ends are snapped into place. A gap will be present between the wrapped legs when installation is completed (Figure 3).
• Trim back rope end as required and install end cap by applying silicone adhesive or similar compound inside cap and pushing cap completely onto end of rope.
• Secure black tie wrap around grip at wire ends to secure ends. Tie wrap should be positioned to within one (1) inch of wire ends of short leg.
FIGURE 3
FIGURE 1
CROSS-OVER MARKS
THIMBLE PHILLYSTRAN
LEGS
FIGURE 2
ARTICULATED HARDWARE RECOMMENDED FOR USE WITH BIG GRIP DEAD-ENDS
Big Grip Dead-End
Heavy Duty or Solid Thimble
Anchor Shackles One Anchor Shackle if one end can be passed through loop of Eye Nut
Eye Nut
Lock Nut
Threaded Anchor Rod
Big Grip Dead-End Heavy Duty or Solid Thimble
Turnbuckle(Jaw & Jaw)
Anchor Rod
Heavy Duty or Solid Thimble
Big Grip Dead-End
Tower Plate
Anchor Shackles
7
INSTALLATION GUIDELINES
• Big Grip dead-ends should be used only on the size for which they are designed. When ordering Big Grip dead-ends, make sure to specify the size on which it is to be used.
• Big Grip dead-ends are precision devices that should be handled carefully. To prevent distortion and damage they should be stored in cartons until used and should be installed under the guidelines in this section.
• During installation and at all times, care should be taken to avoid gouging or damaging the corrosion preventative material of the Big Grip dead-end and of the jacketing on the Phillystran.
• Big Grip dead-ends may be removed and reapplied two times, if necessary, for the purpose of retensioning guys.
• If removal is necessary after a Big Grip dead-end has been installed for a period greater than three months, it must be replaced with a new Big Grip dead-end.
• Big Grip dead-ends should not be applied with tools. They should be applied by hand. However, a screwdriver may be used as an aid in splitting the legs as shown in Figure 3.
• Big Grip dead-ends should not be used on hardware which allows the strand to rotate or spin about its axis uncontrolled. Adjustable hardware, such as a turnbuckle, may be used as long as rotational movement of the strand is restricted.
• Hardware used in conjunction with Big Grip dead-ends should have smooth contours, ample groove clearances, acceptable diameters and sufficient strength to minimize abrasion and fatigue of the loop area. Only heavy-duty type wire rope thimbles are recommended for use with Big Grip dead-ends. To prevent collapse of the thimble, either a solid (Hawser) type thimble, a large pin inside the thimble or where a smaller pin is used, extra strong weight pipe or equivalent is necessary.
• When in doubt about installations, hardware or applications, contact Phillystran.
CAUTION Break Strength: The breaking strength of a rope is the load at which a new rope will break when tested under laboratory conditions. Break strength should not be mistaken for safe working load. Safe Working Load: Because of the wide range of rope use, rope condition and the degree of risk of life or property, it is not possible to make a blanket recommendation for the safe working load. It is ultimately dependent on the rope user to determine the safe working load as a percentage of break strength. Wear: Ropes wear out with use; the more severe the usage, the greater the wear. It is often not possible to detect wear on a rope by visible signs alone. Therefore it is recommended that the rope user determine a retirement criteria for ropes in their application. For assistance in developing safe working load and retirement criteria for each application please call or write Phillystran. All printed statements, data and recommendations are based on reliable information and tests, and are presented without any guarantee or warranty. Statements regarding the use of Philllystran’s products and processes are not to be construed as recommendations for use in violation of any applicable laws, regulations or patent rights.
© All rights reserved.
151 Commerce DriveMontgomeryville, PA 18936-9628 USA+1-215-368-6611 FAX: +1-215-362-7956www.Phillystran.com Fo
rm N
o. 8
012A