phoenix - htp, inc. · 2019-07-18 · phoenix light duty advanced heating ... 3 5 6 7 2 4...

4
Highly Efficient Stainless Steel Gas-Fired Water Heater P h oe n i x LIGHT DUTY Advanced Heating & Hot Water Systems ® ® H T P M a d e I n A m e r i c a H T P M a d e I n A m e r i c a H T P M a d e I n A m e r i c a H T P M a d e I n A m e r i c a 7 6, 00 0 Btuh 50, 60 & 80 Nominal G allo n Tanks Up to 97% Thermal Efficiency Up to .90 UEF Modulating Combustion System 316L Stainless Steel Tank Multiple Venting Options -2” PVC, CPVC or ULC S636 pipe -Combined vent length of 150 ft Solar Version Solar Tank with Gas Fired Back-Up

Upload: others

Post on 28-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Phoenix - HTP, Inc. · 2019-07-18 · Phoenix LIGHT DUTY Advanced Heating ... 3 5 6 7 2 4 Modulating Combustion System-3:1 turndown ratio - 25,000 to 76,000 Btuh -Ultra Low NOx compliant

Highly Efficient Stainless Steel Gas-Fired Water Heater

Phoenix LIGHT DUT Y

Advanced Heating& Hot Water Systems

®

®

HTP Made In Am

erica • HTP Made In A

mer

ic

a • HTP Made In A

merica • HTP Made In

Am

eric

a •

76, 000 Btuh50, 60 & 80Nominal Gallon TanksUp to 97% Thermal Efficiency

Up to .90 UEF Modulating Combustion System 316 L Stainless Steel Tank Multiple Venting Options -2” PVC, CPVC or ULC S636 pipe -Combined vent length of 150 ft

Solar VersionSolar Tankwith Gas Fired Back-Up

SCAQMD Rule 1146.2

Page 2: Phoenix - HTP, Inc. · 2019-07-18 · Phoenix LIGHT DUTY Advanced Heating ... 3 5 6 7 2 4 Modulating Combustion System-3:1 turndown ratio - 25,000 to 76,000 Btuh -Ultra Low NOx compliant

A CLOSER LOOKPhoenix LD

High Efficiency Stainless Steel Gas-Fired Water Heater

NO Anode Rods Needed!All coated tanks require anodes to delay the inevi-table corrosion and tank failure. The Phoenix Light Duty stainless steel tank wil l outlast any coated steel tank in the market!.SCALE BUILD-UP

Heat ExchangerCupronickel spiral design that expands and contracts ra p i d l y w i t h t h e c h a n g e i n temperature resisting scale b u i l d - u p.

-Durable Construction

-High Performance

-Excellent Heat Transfer Capabilities

Fan

Gas Valve

Spark Plug Ignition

Control &Display

2” Air Intake

Hot Outlet Cold Inlet

Auxiliary ReturnT& P

Page 3: Phoenix - HTP, Inc. · 2019-07-18 · Phoenix LIGHT DUTY Advanced Heating ... 3 5 6 7 2 4 Modulating Combustion System-3:1 turndown ratio - 25,000 to 76,000 Btuh -Ultra Low NOx compliant

CONTROL & DISPLAY

FEATURESAdvanced Electronic Control -Easy to read LCD (icon and text) displayHighly Efficient Operation -Up to 97% Thermal Efficiency -Up to .90 Uniform Energy FactorEase of Installation -Top ports on inlet and outlet -Top connect auxiliary port for recirculation line or AIR HANDLER piping, increases overall efficiency

High Efficiency Stainless Steel Gas-Fired Water Heater

Functions1. Menu Navigation Down2. Menu Navigation Up3. Decreases the DHW Setpoint4. Increases the DHW Setpoint5. ECO Mode: provides real energy savings, when less hot water is needed

6. Reset

7. Off / DHW Mode Enable

eco

service

reset

resetreset

Economy Mode 3 Digit DisplayBurner Power Indicator

Temp in Fahrenheit (F)or Celsius (C)

Outdoor Reset CurveReset IconWarning IconDHW Mode

Test Mode orTime for Service

1

3

5 6 7

2

4

Modulating Combustion System - 3:1 turndown ratio - 25,000 to 76,000 Btuh -Ultra Low NOx compliantSuperior 316L Stainless Steel Tank Construction - 3 tank sizes: 50, 60, & 80 nominal gallons - Laser welded precision, lightweight tank - No anode rods neededHighly Efficient Combustion Heat Exchanger - The Phoenix Light Duty uses the latest, patented technology and is covered by U.S. Patent No. 10,024,57, it’s cupronickel heat exchanger design boasts excellent heat transfer properties and resists corrosion - High grade stainless steel burnerVenting - 2” PVC, CPVC or ULC S636 pipe - Combined vent length of 150 feet - Two pipe / single pipe, balanced or unbalanced venting systemThe Phoenix LD performs better than tankless - Avoid inconsistent water fluctuations - No minimum flow rates needed to provide hot water - Deliver hot water to multiple outlets and large volume showers faster

HOT OUTLET

COLD INLET

GAS

CIRCULATORPUMP

EXPANSION TANK

DRAIN VALVE

BACKFLOWPREVENTER

BALL VALVE

T&P LINE

AUXILARYCONNECTION

Phoenix LD Installation with an Air Handler

Page 4: Phoenix - HTP, Inc. · 2019-07-18 · Phoenix LIGHT DUTY Advanced Heating ... 3 5 6 7 2 4 Modulating Combustion System-3:1 turndown ratio - 25,000 to 76,000 Btuh -Ultra Low NOx compliant

MODEL A B C D E FNominal Storage Capacity

Vent Size

GasLine

Inlet/ Outlet Size

Relief Valve

AuxConn.

PH76-50 44.75” 33” 33” 6.75” 23” 32.5” 50 GAL.

2” 1/2” 3/4” NPT 3/4” FNPT 3/4” NPTPH76-60 52.625” 33” 33” 6.75” 23” 32.5” 60 GAL.

PH76-80 69” 33” 33” 6.75” 23” 32.5” 80 GAL.

* Solar

272 Duchaine Blvd, New Bedford, MA 02745 • 1-800-323-9651 • www.htproducts.comMKTLIT-53 - 07/ 2019 © HTP

Speci f icat ionsPhoenix LD

In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.

4.000

FE

HOTOUTLET

AUXILIARY RETURN

COLD INLET

T & P

8.000

C

D

A

B

GALLONS A*

HS76-45

FC

45 42-3/4" 33-1/4"

54-3/4"

36-1/4"

7-1/4" 23" 32-1/4"

HS76-55 60 36-1/4"

36-1/4"

7-1/4"

D

23" 32-1/4"

HS76-75 80 62-3/4" 33-1/4"

E

7-1/4" 23" 32-1/4"

33-1/4"

B# LEDOM

MODEL # INPUT MODULATION

AIR INTAKE/EXHAUST

VENT SIZE

INLET/OUTLET SIZE

AUXILIARY CONN.

GASLINE

CONN.

SYSTEM RELIEF

PIPE SIZE

SHIPPINGWEIGHT

MAX. TEMPERATURE

LIMIT

HS76-45

25,000 -76,000 2" 3/4" 3/4" 1/2" 3/4" 160HS76-55

HS76-75

LP-441-D11/26/12

* HEIGHTS ARE PRELIMINARY

4.000

FE

HOTOUTLET

AUXILIARY RETURN

COLD INLET

T & P

8.000

C

D

A

B

GALLONS A*

HS76-45

FC

45 42-3/4" 33-1/4"

54-3/4"

36-1/4"

7-1/4" 23" 32-1/4"

HS76-55 60 36-1/4"

36-1/4"

7-1/4"

D

23" 32-1/4"

HS76-75 80 62-3/4" 33-1/4"

E

7-1/4" 23" 32-1/4"

33-1/4"

B# LEDOM

MODEL # INPUT MODULATION

AIR INTAKE/EXHAUST

VENT SIZE

INLET/OUTLET SIZE

AUXILIARY CONN.

GASLINE

CONN.

SYSTEM RELIEF

PIPE SIZE

SHIPPINGWEIGHT

MAX. TEMPERATURE

LIMIT

HS76-45

25,000 -76,000 2" 3/4" 3/4" 1/2" 3/4" 160HS76-55

HS76-75

LP-441-D11/26/12

* HEIGHTS ARE PRELIMINARY

MODEL BtuhDOE Rated

Storage Volume

UEF RecoveryEfficiency

FirstHour

Rating

First HourRating

Bin

ThermalEfficiency

Recovery GPH At

90˚ F Rise

Max. Temp Limit

PH76-50 25,000 - 76,000 48 GAL. .90 96% 154 GAL. High 97%98

160˚F-

PH76-60 25,000 - 76,000 58 GAL. .88 97% 157 GAL. High 97%

PH76-80 25,000 - 76,000 77 GAL. .87 94% 206 GAL. High 95%

PH76-80S* 25,000 - 76,000 77 GAL. N/A 94% 206 GAL. High 95 % 107

STANDARD FEATURES- Up to 97% TE and up to .90 UEF - Modulating Burners with Up to 3:1 Turndown Ratio- Vents in PVC, CPVC, Stainless Steel, ULC S636- Spark ignition with flame monitoring - Flame stabilization monitoring - Integrated Control System- Pressure relief pre-piped - Limited Warranty: Residential: 10 year if registered online & 7 year if not registered Commercial: 3 year (upgradeable to 5 year with additional charge)

WHAT’S IN THE BOX- Intake PVC Tee w/ Screens- Exhaust PVC Coupling w/ Screens- Installation Manual- Temperature & Pressure Relief Valve- Warranty

OPTIONAL EQUIPMENT- Outdoor Sensor- 2” or 3” PVC Concentric Vent Kit- 2” or 3” Stainless Steel Outside Termination Vent Kit- 3” Polypro Vent Kit