phoenix plus - htp · 2018-12-04 · htp inc. reserves the right to make changes without prior...

4
Advanced Heating & Hot Water Systems High Efficiency Stainless Steel Indoor / Outdoor Gas Fired Water Heater P h oe n i x P l u s Up to 10 : 1 Turndown Ratio 4 Btuh Sizes 199K * • 260K 320K • 399K Built-in Redundancy (Dual Combustion System) Small Footprint Indoor / Outdoor Installation 316L Stainless Steel Tank An Intelligent Design that Delivers Highly Efficient Water Heating with up to 95% Thermal Efficiency *PHP199-119: features one control panel and one combustion system; cannot be staged; 199K Model: 5:1 turndown ratio

Upload: others

Post on 27-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Phoenix Plus - HTP · 2018-12-04 · HTP Inc. reserves the right to make changes without prior notice. Model Btuh Input Modulation Air Intake Gas Line Gallon Capacity Inlet / Outlet

Advanced Heating & Hot Water Systems

High Efficiency Stainless Steel Indoor / Outdoor

Gas Fired Water Heater

Phoenix Plus

Up to10 : 1Turndown Ratio

4 Btuh Sizes199K * • 260K320K • 399K

Built-in Redundancy(Dual Combustion System)

Small FootprintIndoor / Outdoor Installation

316 L Stainless Steel Tank An Intelligent Design that Delivers Highly Efficient

Water Heating with up to 95% Thermal Efficiency

* P H P 1 9 9 - 1 1 9 : f e a t u r e s o n e c o n t r o l p a n e l a n d o n e c o m b u s t i o n s y s t e m ; c a n n o t b e s t a g e d ; 1 9 9 K M o d e l : 5 : 1 t u r n d o w n r a t i o

Page 2: Phoenix Plus - HTP · 2018-12-04 · HTP Inc. reserves the right to make changes without prior notice. Model Btuh Input Modulation Air Intake Gas Line Gallon Capacity Inlet / Outlet

Indoor / Outdoor

Commercial GasWater HeaterA C L O S E R L O O K

Phoenix Plus

* P H P 1 9 9 - 1 1 9 : f e a t u r e s o n e c o n t r o l p a n e l a n d o n e c o m b u s t i o n s y s t e m ; c a n n o t b e s t a g e d ; 1 9 9 K M o d e l : 5 : 1 t u r n d o w n r a t i o

Dual Low Water Cut-Off Sensorsassure the tank will not operate

unless it is filled with water

Upper Temperature Sensors accurately measures temperature

to control burner input

Combustion Heat Exchanger Stainless Steel/Cupronickel

Combustion Heat Exchanger Stainless Steel/Cupronickel

Exhaust Adaptor to PVC/ CPVC Venting

Combustion System

Combustion System

Lower Temperature Sensorsaccurately measures temperature to control burner input

Built-in Condensate Trap

High Limit Safety

Dual function : Supply Temp Sensor and High Limit Safety

Precision Laser Welded Tank

Temperature and Pressure Relief Valve(Top of Unit)

Tank Constructed of 316L Stainless SteelPrecision Laser Welded

Heavy Duty Indoor– Outdoor Enclosure

Page 3: Phoenix Plus - HTP · 2018-12-04 · HTP Inc. reserves the right to make changes without prior notice. Model Btuh Input Modulation Air Intake Gas Line Gallon Capacity Inlet / Outlet

Indoor / Outdoor

Commercial GasWater Heater

2 Combustion Systems• 4 sizes: 199K*, 260K, 320K, 399K Btuh• Built-in redundancy: dual combustion system*• Indoor or outdoor installation: multiple venting options (indoor)

Super Efficient• Up to 95% thermal efficienc y• Best 1st hour output and recovery • Load-matching modulation • Up to 10:1 turndown ratio: (The 199K model has a 5:1 turndown ratio)

modulates down to 10% of input capacity optimizes energy and reduces cycling, increasing efficiency• Recirculation port on the top section provides additional efficiency• Controls can be adjusted to increase efficiency by staging each combustion system* • Low NOx combustion system meets the most stringent standards

Super Durable• 316 L stainless steel tank, (lightweight) longer service life • Heavy duty outdoor enclosure protects the internal components including the built- in condensate trap• 2 hybrid cupronickel / stainless steel heat exchangers *• No anode rods needed• 119 gallon storage: reduced cycling, adds to component life • No additional storage tanks needed

* P H P 1 9 9 - 1 1 9 : f e a t u r e s o n e c o n t r o l p a n e l a n d o n e c o m b u s t i o n s y s t e m ; c a n n o t b e s t a g e d ; 1 9 9 K M o d e l : 5 : 1 t u r n d o w n r a t i o

Perfect for high demand applications including apartment buildings, restaurants, hotels, schools, hospitals, laundry facilities, office buildings and other commercial jobs.

Digital Displays system monitoring and temperature adjustment- The displays can be mounted inside or on the outside of the cabinet

Condensate Trap

Thick Insulation Control Panel(2 panels*)

Spark Ignition

Commercial

Page 4: Phoenix Plus - HTP · 2018-12-04 · HTP Inc. reserves the right to make changes without prior notice. Model Btuh Input Modulation Air Intake Gas Line Gallon Capacity Inlet / Outlet

272 Duchaine Blvd, New Bedford, MA 02745 • 1-800-323-9651 • www.htproducts.comMKTLIT-52 - 12/ 2018 © HTP

S p e c i f i c a t i o n s

32”

42.1

25”

GAS

ELECTRICAL

CONDENSATE

24.4

5.5”

21”

HOT OUTLET

INTAKE EXHAUST

85”

(77”

for

the

PH

P199

-199

)

58.7

5” (

49” f

or t

he P

HP1

99-1

99)

9.75

AUXILLARY(RECIRC PORT)

COLD INLET

38”

Phoenix Plus

HTP Made In Am

erica • HTP Made In A

mer

ic

a • HTP Made In A

merica • HTP Made In

Am

eric

a •

SCAQMD Rule 1146.2

32”

42.1

25”

GAS

ELECTRICAL

CONDENSATE

24.4

5.5”

21”

HOT OUTLET

INTAKE EXHAUST

85”

(77”

for

the

PH

P199

-199

)

58.7

5” (

49” f

or t

he P

HP1

99-1

99)

9.75

AUXILLARY(RECIRC PORT)

COLD INLET

38”

STANDARD FEATURES- Up to 95% Thermal Efficiency- 2 Modulating Burners - Up to 10 :1 Turndown Ratio (PHP199-199: 1 Burner; 199K model: 5:1 Turndown Ratio)- Vents in PVC, CPVC, Stainless Steel, ULC S636- Spark ignition - Dual flame monitoring (Spark & Flame probe) - Flame stabilization monitoring - Integrated Control System- Pressure relief pre-piped - Built-in low water cut-off probe- Limited 3 Year Commercial Warranty

WHAT’S IN THE BOX- Brass Tee and Bushing- Temperature and Pressure Relief Valve - Installation Manual & Warranty- LP Conversion Kit (Natural Gas Models Only)

OPTIONAL EQUIPMENT- 3” PVC Concentric Vent Kit (for 199K Model)- 3”, 4” Stainless Steel Outside Termination Vent Kit- Condensate Neutralizer- CondensatePump- PC Connection Cable w/ Software

In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.

Model Btuh InputModulation

AirIntake

GasLine

GallonCapacity

Inlet / Outlet

Relief Valve Aux Shipping

Weight

GPH at100˚ FRise

First Hour

Rating

# of Combustion Systems & (Turn-

down Ratio)

PHP199-119 40k – 199k 3”

¾” 119 1 ½” NPT

1” NPT

1” NPT

475 LBS 232 315 1 (5:1)

PHP260-119 35k – 260k4”

555 LBS 303 386 2 (10:1)

PHP320-119 40k – 320k 575 LBS 372 455 2 (10:1)

PHP399-119 40k – 399k 575 LBS 464 574 2 (10:1)