Project Number Date 17.03108 12/11/2017 Lab#6 Sphere P800005-020-30 Photometry Sphere IES LM-16-93 IES LM-79-08 § 10 IES LM-79-08 § 9.1 & 12.1 0:30 Preburn Time: 1:00 1:04 Time To Stabilize: 1:04 2:55 Total Operating Time: 2:04 120.2 Input Voltage (Volts) : 120.0 0.100 Input Current (Amps) : 0.100 12.0 Input Wattage (Watts) : 11.9 24.0 24.0 Checked (sphere) : Checked (photometry) : Approved: Test Method: Test Sample Description Time To Stabilize: Preburn Time: Catalog Number: Description: Test Method: IES LM-46-04 7" Recessed edgelit. T2 Sample. Antique Bronze. Input Current (Amps) : www.hubbelllighting.com Greenville, SC 29607 701 Millennium Boulevard This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 1 of 8 Total Operating Time: Input Voltage (Volts) : Input Wattage (Watts) : Ambient Temp (°C) : Hubbell Lighting, Inc. Ambient Temp (°C) : B.LEE M.ELLMANN

Upload: others

Post on 29-Sep-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

Project Number Date17.03108 12/11/2017

Lab#6Sphere

P800005-020-30

Photometry Sphere IES LM-16-93IES LM-79-08 § 10 IES LM-79-08 § 9.1 & 12.1

0:30 Preburn Time: 1:001:04 Time To Stabilize: 1:042:55 Total Operating Time: 2:04

120.2 Input Voltage (Volts) : 120.00.100 Input Current (Amps) : 0.10012.0 Input Wattage (Watts) : 11.924.0 24.0

Checked (sphere) :Checked (photometry) :

Approved:

Test Method:

Test Sample Description

Time To Stabilize:Preburn Time:

Catalog Number:Description:

Test Method:IES LM-46-04

7" Recessed edgelit. T2 Sample. Antique Bronze.

Input Current (Amps) :

www.hubbelllighting.comGreenville, SC 29607

701 Millennium Boulevard

This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

Page 1 of 8

Total Operating Time:

Input Voltage (Volts) :

Input Wattage (Watts) :Ambient Temp (°C) :

Hubbell Lighting, Inc.

Ambient Temp (°C) :

B.LEEM.ELLMANN

Page 2: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

Test #: 17.03108 Date: 12/11/2017

283528 - Seoul 3000K LEDs1 - Alpha D-PL-A53-01-A V2.0-Y2 Programmed to 100mA

Efficacy: 72.3 LPW 1.4 LM'/LM

Name Value UnitΦ 3.09 watts

Φ(v) 860 lumens

Φ(v') 1221 lm'Chrom x 0.4315Chrom y 0.4014Chrom u 0.2482Chrom v 0.3464

Duv 0.0003

Chrom u' 0.2482Chrom v' 0.5195

CCT 3069 KPurity 50 %

λ (dom) 582.6 nmFWHM 172.7 nmλ (peak) 630 nm

λ (center) 601.2 nmλ (centroid) 595.5 nm

SDCM Cool WhiteRA 93

Corr. Coef. 0.000341242Correlation 0.0054

R1 94.5R2 94.7R3 93.0R4 94.1R5 93.5R6 92.7R7 94.6R8 89.3R9 73.5R10 86.4R11 94.5R12 81.6R13 94.3R14 95.3

Page 2 of 8

S/P Ratio:

Lamp Cat#:

Driver Desc:

This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

Spectral Results

Lamp Desc:

Chromaticity Diagram

0.00E+00

2.00E-03

4.00E-03

6.00E-03

8.00E-03

1.00E-02

1.20E-02

1.40E-02

1.60E-02

1.80E-02

350 450 550 650 750 850

Spec

tral

Rad

iant

Flu

x (W

)

Wavelength (nm)

Spectral Distribution of Radiant Flux

Page 3: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

701 Millennium BlvdGreenville, SC 29607

www.hubbelllighting.com

THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

PAGE: 3 OF 8REPORT NUMBER: 17.03108ISSUE DATE: 12/12/17PREPARED FOR: PROGRESSCATALOG NUMBER: P800005-020-30LUMINAIRE: 7" Recessed edgelit. T2 Sample. Antique Bronze. LAMP CAT. NO.: 2835LAMP: 28 - Seoul 3000K LEDsBALLAST CATALOG NUMBER: D-PL-A53-01-A V2.0-Y2BALLAST: 1-Alpha- set to 100mAMOUNTING: RecessedREFLECTOR: PETREFRACTOR: PolycarbonateNOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED.

Page 4: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

701 Millennium BlvdGreenville, SC 29607

www.hubbelllighting.com

THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

REPORT NUMBER: 17.03108 PAGE: 4 OF 8ISSUE DATE: 12/12/17PREPARED FOR: PROGRESSCATALOG NUMBER: P800005-020-30

DEG CANDELA LUMENS 0 297 5 296 28 15 286 81 25 265 122 35 234 146 45 192 148 55 144 129 65 95 94 75 48 50 85 8 11 90 0

ZONAL LUMEN SUMMARYZONE LUMENS %FIXT

0- 30 231 28.50- 40 377 46.60- 60 654 80.80- 90 809 100.090-180 0 0.00-180 809 100.0

EFFICACY = 67.4 lm/WCIE TYPE - DIRECTSPACING CRITERION: 1.25LUMINOUS DIAMETER: 4.625

LUMINANCE DATA IN CANDELA/SQ MANGLE AVERAGEIN DEG 45 25052. 55 23163. 65 20739. 75 17111. 85 8469.

100

200

300

0˚ 15˚ 30˚

45˚

60˚

75˚

90˚

LEGEND0-deg

Page 5: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

701 Millennium BlvdGreenville, SC 29607

www.hubbelllighting.com

THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

REPORT NUMBER: 17.03108 PAGE: 5 OF 8ISSUE DATE: 12/12/17PREPARED FOR: PROGRESSCATALOG NUMBER: P800005-020-30

CANDELA DISTRIBUTION

0.0 297 2.5 297 5.0 296 7.5 294 10.0 292 12.5 289 15.0 286 17.5 282 20.0 277 22.5 272 25.0 265 27.5 258 30.0 251 32.5 243 35.0 234 37.5 224 40.0 214 42.5 203 45.0 192 47.5 180 50.0 168 52.5 156 55.0 144 57.5 132 60.0 120 62.5 108 65.0 95 67.5 83 70.0 71 72.5 59 75.0 48 77.5 36 80.0 26 82.5 16 85.0 8 87.5 2 90.0 0

Page 6: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

701 Millennium BlvdGreenville, SC 29607

www.hubbelllighting.com

THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

REPORT NUMBER: 17.03108 PAGE: 6 OF 8ISSUE DATE: 12/12/17PREPARED FOR: PROGRESSCATALOG NUMBER: P800005-020-30

5-DEGREEZONAL LUMEN SUMMARY

0- 5 75- 10 21

10- 15 3415- 20 4620- 25 5725- 30 6530- 35 7135- 40 7540- 45 7545- 50 7350- 55 6855- 60 6160- 65 5265- 70 4270- 75 3175- 80 2080- 85 985- 90 2

10-DEGREEZONAL LUMEN SUMMARY

0- 10 280- 20 1090- 30 2310- 40 3770- 50 5250- 60 6540- 70 7480- 80 7990- 90 809

Page 7: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

701 Millennium BlvdGreenville, SC 29607

www.hubbelllighting.com

THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

REPORT NUMBER: 17.03108 PAGE: 7 OF 8ISSUE DATE: 12/12/17PREPARED FOR: PROGRESSCATALOG NUMBER: P800005-020-30

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 119119119119 116116116116 111111111 106106106 102102102 100 1 109105100 97 106102 98 95 98 95 92 94 92 89 91 89 87 85 2 99 91 85 79 97 89 83 78 86 81 76 83 78 75 80 76 73 71 3 91 80 72 66 88 79 71 65 76 69 64 73 68 63 71 66 62 60 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44 6 71 57 49 42 69 57 48 42 55 47 42 53 46 41 51 46 41 39 7 66 52 43 37 64 51 43 37 50 42 37 48 42 37 47 41 36 34 8 61 48 39 33 59 47 39 33 46 38 33 44 38 33 43 37 33 31 9 57 44 36 30 56 43 35 30 42 35 30 41 34 30 40 34 29 28 10 54 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25

ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT AREBASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUESARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.

Page 8: Photometry IES LM-46-04 Sphere IES LM-16-93 Test Method ...€¦ · 4 83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44

Project Number Date17.03108 12/11/2017

Goniophotometer CalibrationCalibration Lamp: GE 1000W, 120V, T6, CL (FEL)Lamp Number: ITL78966-1000-38Calibration Current: 8.300 Amps DCTotal Luminous Flux: 25889.0 LumensCalibration Date: 09/02/16

Test Equipment UsedInstrument Manufacturer / Model S/N Calibration Due:Goniophotometer ITL / HLI LAB 6 - Test Distance: 31.3' N/A N/APower Analyzer Yokogawa / WT 332 C2QA27076V 10/25/2018Power Source Voltage-Regulated House Power N/A N/AThermometer National Instruments / USB-TC01 1912745 10/26/2018

Instrument S/N3-Meter Sphere Labsphere / LMS-3M N/A Calibration Checked DailyThermometer National Instruments / USB TC01 1912751 10/26/2018LAMP Power Meter Yokogawa / WT332 C2QA27075V 10/25/2018Power Supply Chroma / 61602 616020002113 N/A Aux Lamp Supply Labsphere / LPS-100-0833 0331159372 N/A Cal Lamp Supply Labsphere / LPS-150-0268 1218148505 N/A Spectrometer Labsphere / CDS 1100 0624117792

701 Millennium Boulevard

Sphere CalibrationCalibration Lamp: EIKO 28V75W/E10 Lamp Number: SCL-1400-J136 Calibration Current: 2.679 Amps Total Luminous Flux: 1427 Lumens

N/A

Test Equipment Used - Color & SPD; THD & Power Factor

Greenville, SC 29607

Calibration Due:

Hubbell Lighting, Inc.

Manufacturer / Model

This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.