  • 7/29/2019 Pile Design Guide

    1/46

    PRESTRESSED PILI

    TECHNICAL DETAILS AND SAMPLE CALCULATIONS

  • 7/29/2019 Pile Design Guide

    2/46

    Prestressed Piling

    Prestressed concrete piling are vital elements in the foundaons of buildings, bridges and marine structures

    throughout the world. They vary in size from 10 in. (254 mm)

    square piles used in building foundaons to the 66 in. (1676

    mm) diameter cylinder piles used in marine structures

    and bridges. Many areas of North America have poor soilcondions requiring pile foundaons for even relavely light

    structures. In such areas, prestressed concrete piling have

    come to be the usual method of construcon, having been

    proven the logical choice of materials where permanence,

    durability and economy must be considered. Heavy marine

    structures oen rely on prestressed concrete piling driven

    through deep water or through deep layers of unsuitable

    material for their support. Prestressed concrete piling can

    be designed to safely support these heavy loads as well as

    lateral loads caused by wind, waves and earthquakes. In marine environments

    these piles can resist corrosion caused by salt water and by thousands of cycles

    of weng and drying.1

    The following pages contain the

    specicaons and service load

    interacon diagrams for the majority

    of the standard pile sizes for Heldenfels

    Enterprises, Inc. This informaon is

    to be used to assist engineers in the

    design of their projects. This manual is

    not intended to replace the necessityof a profession engineered design.

    1 Recommended Pracce for Design, Manufacture and Installaon of Prestressed Concrete Piling, PCI Commiee on Prestressed Concrete Piling, Mar-Apr 1993

  • 7/29/2019 Pile Design Guide

    3/46

  • 7/29/2019 Pile Design Guide

    4/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    200

    100

    0

    100

    200

    300

    400

    500

    0.0 10.0 20.0 30.0 40.0 50.0 60.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 12 " x 12 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    6000 psi Size=

    4000 psi Qty.= 4

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    200

    100

    0

    100

    200

    300

    400

    500

    0.0 10.0 20.0 30.0 40.0 50.0 60.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    6/9/2010BY SHEET

    cK Structural 12x12A

    5700IH 35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 12"x12"Pile,TypeASTANDARD PILING

  • 7/29/2019 Pile Design Guide

    5/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 100 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 12 inches

    b= 12 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 142 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 4

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 6000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,463,151 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    6/9/2010BY SHEET

    cK Structural 12x12A - info.

    5700I H35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    Engineering Department 12"x12"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    6/46

  • 7/29/2019 Pile Design Guide

    7/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 150 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 12 inches

    b= 12 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 142 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 8

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 7000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,820,754 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    6/9/2010BY SHEET

    cK Structural 12x12B - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 12"x12"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    8/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    200

    100

    0

    100

    200

    300

    400

    500

    0.0 10.0 20.0 30.0 40.0 50.0 60.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 12 " x 12 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    7000 psi Size=

    4000 psi Qty.= 8

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    200

    100

    0

    100

    200

    300

    400

    500

    0.0 10.0 20.0 30.0 40.0 50.0 60.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    6/9/2010BY SHEET

    cK Structural 12x12B

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 12"x12"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    9/46

  • 7/29/2019 Pile Design Guide

    10/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 150 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 14 inches

    b= 14 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 194 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 4

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 6000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,463,151 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    6/9/2010BY SHEET

    cK Structural 14x14A - info.

    5700I H35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    Engineering Department 14"x14"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    11/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 14 " x 14 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    6000 psi Size=

    4000 psi Qty.= 4

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    6/9/2010BY SHEET

    cK Structural 14x14A

    5700IH 35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 14"x14"Pile,TypeASTANDARD PILING

  • 7/29/2019 Pile Design Guide

    12/46

  • 7/29/2019 Pile Design Guide

    13/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 250 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 14 inches

    b= 14 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 194 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 8

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 7000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,820,754 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    6/9/2010BY SHEET

    cK Structural 14x14B - info.

    5700I H35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    Engineering Department 14"x14"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    14/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 14 " x 14 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    7000 psi Size=

    4000 psi Qty.= 8

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    6/9/2010BY SHEET

    cK Structural 14x14B

    5700IH 35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 14"x14"Pile,TypeBSTANDARD PILING

  • 7/29/2019 Pile Design Guide

    15/46

  • 7/29/2019 Pile Design Guide

    16/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 250 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 16 inches

    b= 16 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 254 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 8

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 5000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,074,281 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    17/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 20.0 40.0 60.0 80.0 100.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 16 " x 16 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    5000 psi Size=

    4000 psi Qty.= 8

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 20.0 40.0 60.0 80.0 100.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    18/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 400 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 16 inches

    b= 16 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 254 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 12

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 7000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,820,754 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16B - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    19/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    800

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 16 " x 16 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    7000 psi Size=

    4000 psi Qty.= 12

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    800

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16B

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    20/46

  • 7/29/2019 Pile Design Guide

    21/46

  • 7/29/2019 Pile Design Guide

    22/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 400 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 18 inches

    b= 18 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 332 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 10

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 5000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,074,281 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 18x18A - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 18"x18"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    23/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    800

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 18 " x 18 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    5000 psi Size=

    4000 psi Qty.= 10

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    700

    800

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 18x18A

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 18"x18"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    24/46

  • 7/29/2019 Pile Design Guide

    25/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 575 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 18 inches

    b= 18 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 332 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 12

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 7000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,820,754 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 18x18B - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 18"x18"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    26/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 18 " x 18 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    7000 psi Size=

    4000 psi Qty.= 12

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 18x18B

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 18"x18"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    27/46

  • 7/29/2019 Pile Design Guide

    28/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 500 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 20 inches

    b= 20 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 398 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 16

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 6000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,463,151 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 20x20A - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 20"x20"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    29/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 20 " x 20 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    6000 psi Size=

    4000 psi Qty.= 16

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 20x20A

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 20"x20"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    30/46

  • 7/29/2019 Pile Design Guide

    31/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 800 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 20 inches

    b= 20 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 398 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 16

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 8000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4500 psi(RequiredConcreteReleaseStrength)

    Ec= 5,153,603 psi(concretemodulusofelasticityat28days)

    Eci= 3,865,202 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 20x20B - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 20"x20"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    32/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    1,400

    1,600

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 20 " x 20 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    8000 psi Size=

    4500 psi Qty.= 16

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    1,400

    1,600

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 20x20B

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 20"x20"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    33/46

  • 7/29/2019 Pile Design Guide

    34/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 800 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 24 inches

    b= 24 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 574 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 20

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 6000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4000 psi(RequiredConcreteReleaseStrength)

    Ec= 4,463,151 psi(concretemodulusofelasticityat28days)

    Eci= 3,644,147 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 24x24A - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 24"x24"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    35/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    600

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    1,400

    1,600

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0 320.0 360.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 24 " x 24 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    6000 psi Size=

    4000 psi Qty.= 20

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    600

    400

    200

    0

    200

    400

    600

    800

    1,000

    1,200

    1,400

    1,600

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0 320.0 360.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 24x24A

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 24"x24"Pile,TypeASTANDARDPILING

  • 7/29/2019 Pile Design Guide

    36/46

  • 7/29/2019 Pile Design Guide

    37/46

    DesignCriteria

    1)ServiceLoadDesign.

    2)Allowable

    Compressive

    Stress

    =0.45f'c

    for

    SUSTAINED

    LOADS.

    3)AllowableTensionStress=0forSUSTAINEDLOADS.

    4)ForTEMPORARYLOADS,AllowableCompressiveStress=0.60f'c.

    5)ForTEMPORARYLOADS,AllowableTensionStress=0.

    6)Assumeasustainedcompressionserviceloadequalto: 1200 kips.

    7)UsePCImethodforestimatingprestresslosses.

    8)BendingisaboutprincipleaxesANDonlyoneaxisatatime.

    9)Slendernessisnotconsidered.

    10)Ultimatecapacitymustbecheckedtoensuretherequiredfactorof

    safetyisachievedinaccordancewithACI318.

    DesignInput

    SectionSize:

    h= 24 inches

    b= 24 inches

    SectionArea(accountingforchamfers,radii,etc.):

    Ag= 574 squareinches

    Precast/PrestressedPiling:DesignCriteriaandInput

    PrestressingStrand:

    Type= 270 ksi,Lolax

    Size=

    1/2"(std.)

    Qty.= 20

    Area= 0.153 squareinchesperstrand

    Pull= 75% (initial)

    Concrete:

    wc= 145 pcf(concreteweight)

    f'c= 8000 psi(28dayConcreteCompressiveStrength)

    f'ci= 4500 psi(RequiredConcreteReleaseStrength)

    Ec= 5,153,603 psi(concretemodulusofelasticityat28days)

    Eci= 3,865,202 psi(concretemodulusofelasticityattransferofprestress)

    DATE

    2/12/2010BY SHEET

    cK Structural 24x24B - info.

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.heldenfel s.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 24"x24"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    38/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    600

    200

    200

    600

    1,000

    1,400

    1,800

    2,200

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0 320.0 360.0 400.0 440.0 480.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 24 " x 24 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    8000 psi Size=

    4500 psi Qty.= 20

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    600

    200

    200

    600

    1,000

    1,400

    1,800

    2,200

    0.0 40.0 80.0 120.0 160.0 200.0 240.0 280.0 320.0 360.0 400.0 440.0 480.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 24x24B

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 24"x24"Pile,TypeBSTANDARDPILING

  • 7/29/2019 Pile Design Guide

    39/46

  • 7/29/2019 Pile Design Guide

    40/46

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    41/46

    Precast/PrestressedPiling:PointsforServiceLoadInteractionDiagram SustainedLoads

    EffectiveForceinStrand,Feff

    Feff= 24,729 lbs

    EffectivePrestressinPile, eff

    fpc = 779 psi

    Point1 UpperBoundary(CompressionOnly,NoBending M1=0)

    P1/A+M1/S+fpc=0.45f'c

    A= 254 squareinches

    M1= 0

    S= 683 inches^3

    P1= 373,666 lbs

    Point2 CompressionwithMinimumEccentricity(5%)

    P2/A+M2/S+fpc=0.45f'c

    emin= 0.80 (minimumeccentricity)

    M2= 0.80 P lb*inches

    P2= 287,955 lbs

    M2= 19.2 kip*feet

    Point3 CrossoverFromCompressiontoTensionControls

    PartA: P3/A+M3/S+fpc=0.45f'c

    PartB: P3/A M3/S+fpc=0 OR P3=A[(M/S) fpc]

    RewritePartA: A[(M3/S) fpc]/A+M3/S+fpc=0.45f'c

    SolveforM3:

    M3= 768,000 kip*inches

    M3= 64.0 kip*feet

    SolveforP3:

    P3=A[(M3/S) fpc]

    P3= 87,916 lbs

    Point4 TensionControlsandM=0

    P4/A 0/S+fpc=0

    P4= 197,834 lbs

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A_02

    5700I H35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    42/46

    Precast/PrestressedPiling:PointsforServiceLoadInteractionDiagram Sustained+TemporaryLoads

    EffectiveForceinStrand,Feff

    Feff= 24,729 lbs

    EffectivePrestressinPile, eff

    eff= 779 psi

    Point1 UpperBoundary(CompressionOnly,NoBending)

    P1/A+M1/S+fpc=0.60f'c

    A= 254 squareinches

    M1= 0

    S= 683 inches^3

    P1= 564,166 lbs

    Point2 CompressionwithMinimumEccentricity(5%)

    P2/A+M2/S+fpc=0.60f'c

    emin= 0.80 (minimumeccentricity)

    M2= 0.80 P lb*inches

    P2= 434,758 lbs

    M2= 29.0 kip*feet

    Point3 CrossoverFromCompressiontoTensionControls

    PartA: P3/A+M3/S+fpc=0.60f'c

    PartB: P3/A M3/S+fpc=0 OR P3=A[(M/S) fpc]

    RewritePartA: A[(M3/S) fpc]/A+M3/S+fpc=0.60f'c

    SolveforM3:

    M3= 1,024,000 kip*inches

    M3= 85.3 kip*feet

    SolveforP3:

    P3=A[(M3/S) fpc]

    P3= 183,166 lbs

    Point4 TensionControlsandM=0

    P4/A 0/S+fpc=0

    P4= 197,834 lbs

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A_03

    5700I H35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    43/46

    DiagramPoints Sustained+Temp.Loads

    P1= 373,666 lbs P1= 564,166 lbs

    M1=

    0.0 kip*feet M1=

    0.0 kip*feet

    P2= 287,955 lbs P2= 434,758 lbs

    M2= 19.2 kip*feet M2= 29.0 kip*feet

    P3= 87,916 lbs P3= 183,166 lbs

    M3= 64.0 kip*feet M3= 85.3 kip*feet

    P4= 197,834 lbs P4= 197,834 lbs

    M4= 0.0 kip*feet M4= 0.0 kip*feet

    Standard Building Code Equation for Maximum Axial Loa

    Pmax= (0.33f'c 0.27fpc)Ag

    Pmax= 365,685 lbs

    Precast/PrestressedPiling:PointsforServiceLoadInteractionDiagram

    DiagramPoints SustainedLoads

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A_04

    5700IH 35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARD PILING

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    44/46

    Precast/PrestressedPiling:ServiceLoadInteractionDiagram

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 20.0 40.0 60.0 80.0 100.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendin Moment ki *feet

    ServiceLoadInteractionDiagram

    PileSize= 16 " x 16 "PrestressingStrand

    NormalWeight Type= 270 ksi,Lolax

    5000 psi Size=

    4000 psi Qty.= 8

    Area= 0.153 in2

    Pull= 75%

    Concrete

    1/2"(std.)

    300

    200

    100

    0

    100

    200

    300

    400

    500

    600

    0.0 20.0 40.0 60.0 80.0 100.0

    Serv

    iceAxialLoad

    (kips)

    ServiceBendingMoment(kip*feet)

    ServiceLoadInteractionDiagram

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A

    5700IH35South,SanMarcos,TX 78666,phone,512.396.2376,www.hel denfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    45/46

    PCI6thEd.Handbook4.7.3

    PrestressLosses

    TL=ES+CR+SH+RE TL=TotalLosses(psi)

    PCIEq.4.7.3.1 ES=ElasticShortening(psi)

    CR=CreepofConcrete(psi)

    SH=ShrinkageofConcrete(psi)

    RE=RelaxationofTendons(psi)

    ElasticShortening(ES)

    ES=KesEpsfcir/Eci Kes = 1.0 forpretensionedmembers

    PCIEq.4.7.3.2 Eps= 28,500,000 psi

    Eci= 3,644,147 psi

    fcir=Kcir*[Pi/Ag

    +Pi*e2/Ig]

    Mg*e/Ig

    (PCI

    Eq.

    4.7.3.3)

    Kcir= 0.9 forpretensionedmembers

    Pi= 247,860 lbs

    Ag= 254 squareinches

    e= 0 inches

    Ig= 5,461 inches4

    M = 0 ki *inches

    Precast/PrestressedPiling:PrestressLossCalculations

    fcir= 878 psi

    ES= 6,869 psi

    Creepof

    Concrete

    (CR)

    CR=Kcr(Eps/Ec)(fcir+fcds) Kcr= 2.0 NormalWeightConcrete

    PCIEq.4.7.3.4 Ec= 4,074,281 psi

    fcds= Pd/Ag+Msd(e)/Ig PCIEq.4.7.3.5

    Msd= 0 kip*inches

    fcds= 984 psi

    CR= 26,057 psi

    ShrinkageofConcrete(SH)

    SH=(8.2x106

    )KshEps(1 0.06V/S)(100 R.H.)

    PCIEq.

    4.7.3.6 Ksh= 1.0 forpretensionedmembers

    V/S= 4.00 inches

    R.H.= 75 % PCIFig.3.10.12

    SH= 4,440 psi

    DATE

    2/12/2010BY SHEET

    cK Structural 16x16A_06

    5700IH 35South,Sa nMarcos,TX 78666,phone,512.396.2376,www.heldenfels.com

    Heldenfels Enterprises, Inc.

    EngineeringDepartment 16"x16"Pile,TypeASTANDARDPILING

    Sample Calculations

  • 7/29/2019 Pile Design Guide

    46/46

    PCI6thEd.Handbook4.7.3

    PrestressLosses(continued)

    Relaxationof

    Tendons

    (RE)

    RE=[Kre J(SH+CR+ES)]C Kre= 5,000 for270ksi,LolaxStrand

    PCIEq.4.7.3.7 PCITable4.7.3.1

    J= 0.040 for270ksi,LolaxStrand

    PCITable4.7.3.1

    fpi/fpu= 0.75

    C= 1.00

    SeeTableBelow

    RE= 3,505 psi

    fpi/fpu CValue

    0.80 1.28

    0.79 1.22

    0.78 1.16

    0.77 1.11

    0.76 1.05

    0.75 1.00

    0.74 0.95

    Precast/PrestressedPiling:PrestressLossCalculations

    For

    Lolax

    Strand

    . .

    0.73 0.90

    0.72 0.85

    0.71 0.800.70 0.75

    0.69 0.70

    0.68 0.66

    0.67 0.61

    0.66 0.57

    0.65 0.53

    0.64 0.49

    0.63 0.45

    0.62 0.41

    0.61 0.37

    0.60 0.33

    TotalLosses,TL

    TL= 40,871 psi

    Heldenfels Enterprises, Inc.

    Sample Calculations