pipe inspection systems - visiconsult pipe...standard testcycle 6 start of testcycle test position...
TRANSCRIPT
![Page 1: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/1.jpg)
Pipe inspection systems
![Page 2: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/2.jpg)
Typical setup
2
![Page 3: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/3.jpg)
Specifications
3
Weld types Longitudinal welds Spiral welds Circumferential/planar welds
DimensionsPipe length : up to 20 mDiameter : 10“ – 60“Wall thickness : 5mm-75 mmMaterial : (Stainless) steel
![Page 4: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/4.jpg)
Typical setup
4
![Page 5: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/5.jpg)
Typical setup
5
![Page 6: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/6.jpg)
Standard Testcycle
6
Start of testcycle Test position reached End of Testcyle
Pipe moves in
Parallel pipe lengthmaesurement
Doors close automatically
Step-wise inspection of all welds
Images stored for everyposition
Optional: Faulty positionsare marked on the tube
Doors open
Pipe moves out
![Page 7: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/7.jpg)
Mechanical options
7
Moving Pipe carrier:- Detector and tube have a fixed position+ Lower costs- Longer bunker ( 2* max tube length )
Fixed pipe position:- Detector and tube have a variable and syncronised position+ Higher costs due o complex mechanics- Short bunker ( 1* max tube length )
Choice depending on space and budget considerations!
![Page 8: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/8.jpg)
XplusPipe Software
8
![Page 9: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/9.jpg)
XplusPipe Software
9
Positioning control and safety indicators
Pipe meta data for automatic imageoverlay
![Page 10: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/10.jpg)
XplusPipe Software
10
X-ray conrol
Collisiondetection
System status
![Page 11: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/11.jpg)
Inspection Standards
11
Meets international standards (EN/ISO 17636-2-2013, ASTM etc.)
Class B is fullfilled (proof trough IQI)
![Page 12: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/12.jpg)
Inspection Standards
12
Meets international standards (EN/ISO 17636-2-2013, ASTM etc.)
Class B is fullfilled (proof trough IQI)
![Page 13: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/13.jpg)
X-ray images
13
![Page 14: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/14.jpg)
The X-ray setup
14
The wall thickness range is influencing the choice of the detector and the X-ray setup:
Max. Wall thickness Energy (Max. kV)Min. Wall thickness Detector resolution (pixel sizeMin diameter of pipe Fitting of the detector for single wall
![Page 15: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/15.jpg)
References
15
Company Country Material
Sosta Germany Stainless Steel
Butting Germany Stainless Steel
Corinth Pipe Works Greece Steel
SMS Meer Germany, South Korea,Malaysia, Saudi Arabia
Steel
PFW Germany Titanium
![Page 16: Pipe inspection systems - VisiConsult Pipe...Standard Testcycle 6 Start of testcycle Test position reached End of Testcyle Pipe moves in Parallel pipe length maesurement Doors close](https://reader033.vdocument.in/reader033/viewer/2022042001/5e6de47b6c0e0438223306e3/html5/thumbnails/16.jpg)
Thanks for your attention!