FREEDOM ELEVATORS BY MCE PLANNING GUIDE

Upload: phamkhanh

Post on 19-Feb-2019

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

FREEDOM™ ELEVATORS BY MCE

PLANNING GUIDE

Page 2: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Contents

Freedom™ Elevators by MCE 3

The Freedom™ Difference 4

Product Summary 5

MRL Planning Guide 6-9

Machine Room 2:1 Planning Guide 10-13

Machine Room 1:1 Planning Guide 14-17

Electrical Requirements and Heat Release 18

High Rise Technology for Low and 19 Mid-Rise Applications

Finishes 20-26

Destination Based Dispatching 27

Monitoring and Peripherals 28-29

Work by Others 30

Page 3: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Freedom™ Elevators by MCE

Freedom. The core of MCE’s product design philosophy.

MCE pioneered an industry by giving building owners the freedom

to choose elevator control equipment that is serviceable and

maintainable by any qualified elevator service provider.

Today at MCE, the future is still about Freedom.

Introducing Freedom™ Elevators by MCE — complete elevators that start with industry lead-ing controls and machines from MCE and Imperial Electric — and include industry standard wire hoist rope, cast iron sheaves, safeties and roller guides.

Crafted with precision in our state-of-the-art 3D design center — and constructed for reliability, performance and future serviceability, Freedom™ Elevators now give building owners a choice when it comes to complete elevators.

Before selecting your next elevators, be sure that any qualified elevator service provider can offer the service, parts, technical support, diagrams, manu-als, and factory training that you’ll have with non-proprietary, serviceable and maintainable Freedom™ Elevators.

Once you’ve made this distinction, you’ll find the clear choice to be Freedom™ by MCE.

3

Page 4: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

The Freedom™ Difference4

Standard Package Features

Hoist ropes

Industry standard traction steel wire rope. Pre-cut to required lengths and shipped on individual spools. This time tested suspension means is available from multiple vendors for future service purposes.

Car sling

Heavy duty car frame constructed of structural C-channel and angles de-signed in conjunction with the safety plank and sheave beams. C-channel crosshead bolted to stiles supported with gussets.

Motor cable

VFD shielded and jacketed motor wire is included with every Freedom™ elevator providing a high degree of noise immunity and reduced induc-tance potential.

Door operators

Industry standard high performance door operator equipment featuring encoderless VVVF closed loop tech-nology. Components available from multiple sources.

Safeties

Industry standard Type “B” flexible guide clamp or Type “A” instanta-neous safeties (depending on speed) mounted under C-channel safety plank.

Governors

Friction type, centrifugal, jawless governor with remote set/reset capability. Industry standard jaw type governors utilized for overhead machine room applications.

Isolation transformers

Reduces and/or eliminates line distortion and pollution back into building power distribution system. Electrically isolates motor and drive from other sensitive equipment in the building.

Platform construction

Utilizes heavy duty welded angle, C-channel floor joist construction with fire resistant sheet steel under-side. Two layers of ¾” high density plywood secured with flush elevator bolts.

Roller guides

High quality car and counterweight roller guides come standard and are specifically engineered for the speed and duty of the car. Car and counter-weight roller guide mounting plates with integral rail retention means are also included for additional safety.

Counterweight package

Heavy duty C-channel and plate members comprise the rigid coun-terweight frame. Counterweight safeties included with occupied space under pit.

Overhead structure

Engineered I–beams, C-channels and plate materials are used to build the traditional Freedom™ overhead structure. Loads are transferred onto the building structure through points designated on the MCE shop drawings.

Car and counterweight sheaves

Traditional cast iron compound sheaves are fastened to the sheave plank with heavy-duty pillow blocks. Large bearings are designed to exceed loads without compromising serviceability or utilizing non-standard technology.

Page 5: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

5Freedom™ Product Summary

Freedom™ Machine Room-Less (MRL)

Speed 150, 200, 350 and 500 fpm

Capacity 2100 - 5000 lbs.

Openings 2 to 32 landings with front and rear applications

Travel 300 ft. of total travel

Control Motion 4000 MRL or iControl

Machine type Alternating Current Permanent Magnet (ACPM) gearless

Operation Simplex, Duplex and Group (up to 15 cars)

Freedom™ Machine Room 2:1

Speed 150, 200, 350 and 500 fpm

Capacity 2100 - 5000 lbs.

Openings 2 to 32 landings with front and rear applications

Travel 300 ft. of total travel

Control Motion 4000 or iControl

Machine type Alternating Current Permanent Magnet (ACPM) gearless

Operation Simplex, Duplex and Group (up to 15 cars)

Freedom™ Machine Room 1:1

Speed 150, 200, 350 and 500 fpm

Capacity 2100 - 5000 lbs.

Openings 2 to 32 landings with front and rear applications

Travel 300 ft. of total travel

Control Motion 4000 or iControl

Machine type Alternating Current Permanent Magnet (ACPM) gearless

Operation Simplex, Duplex and Group (up to 15 cars)

Freedom™ Standard Features

Entrances7’ – 0” high entrances, UL listed jambs and door panels as required, aluminum sills, stainless steel #4 jamb and door panels, adhesive backed jamb Braille, 1/2" solid bar stock door tops, welded internal ribs with solid door backs

Cab shell 8' - 0" cab height, 14 gauge steel shell, Jetcoat with sound deadening exterior, aluminum car sill

Wall panelsRemovable ¾” vertical raised panels, fire rated particle board, faced and edge banded with a non-premium plastic laminate from MCE’s pre-selected Wilsonart® plastic laminate selections

Base and reveals Stainless steel #4

Handrail 1 ½” tubular handrail with stainless steel #4 finish located on rear wall for front opening applications and side walls for front and rear applications

Cab front Fixed stainless steel #4 returns, columns and transom

Canopy 12 gauge rolled steel, primer gray exterior, powder coated reflective white, escape hatch flush with canopy, mechanical lock and electric switch

Drop ceiling 14 gauge stainless steel #4 tee bar frame with fluorescent lights over polygal diffuser

Car fixturesMain car operating panel: Hinged stainless steel #4 faceplate, round plastic buttons, digital car position indicator, code required items and engraving as needed

Hall fixtures Hall stations: Flush stainless steel plates with round plastic buttons, code required features and engraving as needed

Contact your MCE representative for a complete copy of the Freedom™ Technical Specifications.

Page 6: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

6

HW1

DO

CSD

HD HD

CRD HD

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD HD

REMOTECONTROL ROOM

ADJA

CEN

TCO

NTR

OL S

PACE

Freedom™ Machine Room-Less (MRL) - Front Opening

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

Page 7: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

7

Freedom™ Machine Room-Less (MRL) - Front Opening

2100 2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

Passenger capacity 2 13 15 18 21 25 25 28 31 31

Gurney compliance (24" x 76" or 24" x 84") 5 N 76" 76" 84" 84" 84" 84" 84" 84"

1SPSS1SPSS

CO1SPSS

CO1SPSS

CO2SPSS

CO2SPSS

CO2SPSS

CO2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 5' - 8" 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 6" 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 25.5 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4

DO Car door width 3' - 0" 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 8' - 9" 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones1 8' - 11" 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway1 17' - 10" 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones1 18' - 2" 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway1 26' - 11" 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones1 27' - 5" 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

In seismic zones 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

RW Rough opening width (minimum) 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 16' - 10" 16' - 10" 16' - 10" 16' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10"

@ 200 fpm 4 17' - 0" 17' - 0" 17' - 0" 17' - 0" 17' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10"

@ 350 fpm 4 17' - 10" 17' - 10" 17' - 10" 17' - 10" 18' - 5" 18' - 5" 18' - 5" 18' - 5" 18' - 5"

@ 500 fpm 4 18' - 10" 18' - 10" 18' - 10" 18' - 10" 19' - 5" 19' - 5" 19' - 5" 19' - 5" 19' - 5"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

CSD Control space - single car

CRD Control room - single car

CRD Control room - double car

CRD Control room - triple car

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clearunder anything in the overhead structure.

Passenger Hospital

HD x 2' - 10" (minimum) HD x 2' - 10" (minimum)

Control Closet / Room

Hoistway

Car 3

Capacity

Door types5

HD x 7' - 0" (minimum)

HD x 9' - 0" or W x D HD x 9' - 0" or W x D

8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

HD x 5' - 0" (minimum) HD x 5' - 0" (minimum)

HD x 7' - 0" (minimum)

Page 8: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

8

Freedom™ Machine Room-Less (MRL) - Front & Rear Openings

HW1

DO

CSD

HD HD

CRD HD

RW

DO

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD HD

REMOTECONTROL ROOM

ADJA

CEN

TCO

NTR

OL S

PACE

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

Page 9: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

9

2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

15 18 21 25 25 28 31 31

76" 76" 84" 84" 84" 84" 84" 84"

1SPSS CO

1SPSS CO

1SPSS CO

2SPSS CO

2SPSS CO

2SPSS CO

2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4

DO Car door width 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones 1 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway 1 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones1 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway 1 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones 1 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 8" 7' - 4" 8 '- 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

In seismic zones 6' - 8" 7' - 4" 8' - 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

RW Rough opening width (minimum) 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 16' - 10" 16' - 10" 16' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10"

@ 200 fpm 4 17' - 0" 17' - 0" 17' - 0" 17' - 10" 17' - 10" 17' - 10" 17' - 10" 17' - 10"

@ 350 fpm 4 17' - 10" 17' - 10" 18' - 5" 18' - 5" 18' - 5" 18' - 5" 18' - 5" 18' - 5"

@ 500 fpm 4 18' - 10" 18' - 10" 18' - 10" 19' - 5" 19' - 5" 19' - 5" 19' - 5" 19' - 5"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

CSD Control space - single car

CRD Control room - single car HD x 5' - 0" (minimum)

CRD Control room - double car HD x 7' - 0" (minimum)

CRD Control room - triple car HD x 9' - 0" or W x D

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

Door types5

Gurney compliance (24" x 76" or 24" x 84") 5

Passenger capacity 2

Hoistway

8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

Car 3

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clear under anything in the overhead structure.

Control Closet / Room

HD x 2' - 10" (minimum)HD x 2' - 10" (minimum)

HD x 5' - 0" (minimum)

HD x 7' - 0" (minimum)

HD x 9' - 0" or W x D

HospitalPassenger

Capacity

Freedom™ Machine Room-Less (MRL) - Front & Rear Openings

Page 10: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

10

HW1

DO

HD

HW1HW2HW3 HD

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD

MRH

HD

MACHINE ROOM

Freedom™ Machine Room (MR) 2:1 - Front Opening

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

Page 11: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

11

Freedom™ Machine Room (MR) 2:1 - Front Opening

2100 2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

Passenger capacity 2 13 15 18 21 25 25 28 31 31

Gurney compliance (24" x 76" or 24" x 84") 5 N 76" 76" 84" 84" 84" 84" 84" 84"

1SPSS1SPSS

CO1SPSS

CO1SPSS

CO2SPSS

CO2SPSS

CO2SPSS

CO2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 5' - 8" 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 6" 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 25.5 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4

DO Car door width 3' - 0" 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 8' - 9" 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones 1 8' - 11" 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway 1 17' - 10" 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones 1 18' - 2" 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway 1 26' - 11" 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones 1 27' - 5" 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

In seismic zones 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

RW Rough opening width (minimum) 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 200 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 350 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 500 fpm 4 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

Control room - single car

Control room - double car HD x HW2 (minimum) HD x HW2 (minimum)

Control room - triple car HD x HW3 (minimum) HD x HW3 (minimum)

MRH Machine room height (minimum) 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

Hoistway

Car 3

Machine Room

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clear under anything in the overhead structure.

HD x HW1 (minimum) HD x HW1 (minimum)

8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

Hospital

Door types5

Capacity

Passenger

Page 12: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

12

Freedom™ Machine Room (MR) 2:1 - Front & Rear Openings

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

HW1

DO

HD

HW1HW2HW3 HD

RW

DO

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD

MRH

HD

MACHINE ROOM

Page 13: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

13

2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

15 18 21 25 25 28 31 31

76" 76" 84" 84" 84" 84" 84" 84"

1SPSS CO

1SPSS CO

1SPSS CO

2SPSS CO

2SPSS CO

2SPSS CO

2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4

DO Car door width 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones 1 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway 1 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones 1 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway 1 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones 1 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 8" 7' - 4" 8' - 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

In seismic zones 6' - 8" 7' - 4" 8' - 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

RW Rough opening width (minimum) 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 200 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 350 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 500 fpm 4 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

Control room - single car HD x HW1 (minimum) HD x HW1 (minimum)

Control room - double car HD x HW2 (minimum) HD x HW2 (minimum)

Control room - triple car HD x HW3 (minimum) HD x HW3 (minimum)

MRH Machine room height (minimum) 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

Car 3

Capacity

Passenger capacity 2

Gurney compliance (24" x 76" or 24" x 84") 5

Door types5

Passenger Hospital

8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clear under anything in the overhead structure.

Machine Room

Hoistway

Freedom™ Machine Room (MR) 2:1 - Front & Rear Openings

Page 14: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

14

HW1

DO

HD

HW1HW2HW3 HD

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD

MRH

HD

MACHINE ROOM

Freedom™ MCE Machine Room (MR) 1:1 - Front Opening

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

Page 15: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

15

Freedom™ MCE Machine Room (MR) 1:1 - Front Opening

2100 2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

13 15 18 21 25 25 28 31 31

N 76" 76" 84" 84" 84" 84" 84" 84"

1SPSS1SPSS

CO1SPSS

CO1SPSS

CO2SPSS

CO2SPSS

CO2SPSS

CO2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 5' - 8" 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 6" 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 25.5 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4 8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

DO Car door width 3' - 0" 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 8' - 9" 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones 1 8' - 11" 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway 1 17' - 10" 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones 1 18' - 2" 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway 1 26' - 11" 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones 1 27' - 5" 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

In seismic zones 6' - 7 1/2" 6' - 7 1/2" 7' - 1 1/2" 7' - 10" 7' - 10" 9' - 5" 9' - 11" 10' - 6" 11' - 0"

RW Rough opening width (minimum) 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 200 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 350 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 500 fpm 4 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

Control room - single car HD x HW1 (minimum) HD x HW1 (minimum)

Control room - double car HD x HW2 (minimum) HD x HW2 (minimum)

Control room - triple car HD x HW3 (minimum) HD x HW3 (minimum)

MRH Machine room height (minimum) 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clear under anything in the overhead structure.

Hoistway

Machine Room

Passenger Hospital

Door types5

Car 3

Capacity

Passenger Capacity 2

Gurney Compliance (24" x 76" or 24" x 84") 5

Page 16: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

16

Freedom™ MCE Machine Room (MR) 1:1 - Front & Rear Openings

HW1

DO

HD

HW1HW2HW3 HD

RW

DO

RW

CW

HW2

HW3

CH DH

PD

RH OH

CD

MRH

HD

MACHINE ROOM

Maximum travel: 300 ft.

Maximum stops: 32

Speed (ft/min.): 150, 200, 350 and 500 fpm

For additional assistance, please contact MCE at 800.444.7442 x545 or [email protected].

Page 17: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

17

Freedom™ MCE Machine Room (MR) 1:1 - Front & Rear Openings

2500 3000 3500 4000 H4000 H4500 H5000 H5000 AIA

15 18 21 25 25 28 31 31

76" 76" 84" 84" 84" 84" 84" 84"

1SPSS CO

1SPSS CO

1SPSS CO

2SPSS CO

2SPSS CO

2SPSS CO

2SPSS 2SPCO

2SPSS 2SPCO

CW Interior width 6' - 9" 6' - 9" 6' - 9" 7' - 9" 5' - 9" 5' - 9" 6' - 0" 5' - 9"

CD Interior depth 4' - 4" 5' - 0" 5' - 8" 5' - 6" 7' - 5" 8' - 1" 8' - 6" 9' - 0"

Square footage 29.3 33.8 38.3 42.6 42.6 46.5 51.0 51.8

CH Interior height 4 8' - 0" (Optional cab heights up to 10' - 0") 8' - 0" (Optional cab heights up to 10' - 0")

DO Car door width 3' - 6" 3' - 6" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 0"

HW1 Single hoistway 1 9' - 10" 9' - 10" 9' - 10" 10' - 10" 8' - 10" 8' - 10" 9' - 1" 8' - 10"

In seismic zones 1 10' - 0" 10' - 0" 10' - 0" 11' - 0" 9' - 0" 9' - 0" 9' - 3" 9' - 0"

HW2 Double hoistway 1 20' - 0" 20' - 0" 20' - 0" 22' - 0" 18' - 0" 18' - 0" 18' - 6" 18' - 0"

In seismic zones 1 20' - 4" 20' - 4" 20' - 4" 22' - 4" 18' - 4" 18' - 4" 18' - 10" 18' - 4"

HW3 Triple hoistway 1 30' - 2" 30' - 2" 30' - 2" 33' - 2" 27' - 2" 27' - 2" 27' - 11" 27' - 2"

In seismic zones 1 30' - 8" 30' - 8" 30' - 8" 33' - 8" 27' - 8" 27' - 8" 28' - 5" 27' - 8"

HD Hoistway depth 6' - 8" 7' - 4" 8' - 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

In seismic zones 6' - 8" 7' - 4" 8' - 0" 8' - 4" 10' - 3" 10' - 11" 11' - 4" 11' - 10"

RW Rough opening width (minimum) 4' - 0" 4' - 0" 4' - 0" 4' - 6" 4' - 6" 4' - 6" 5' - 0" 4' - 6"

RH Rough opening height (minimum) 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3" 7' - 3"

DH Clear opening height 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"

OH Clear overhead for 8' - 0" car @ 150 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 200 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 350 fpm 4 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6" 13' - 6"

@ 500 fpm 4 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2" 14' - 2"

PD Minimum pit depth @ 150 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 200 fpm 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 6"

@ 350 fpm 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

@ 500 fpm 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6" 6' - 6"

Control room - single car HD x HW1 (minimum) HD x HW1 (minimum)

Control room - double car HD x HW2 (minimum) HD x HW2 (minimum)

Control room - triple car HD x HW3 (minimum) HD x HW3 (minimum)

MRH Machine room height (minimum) 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"

1 For elevators with occupied space below the elevator pit, this dimension will change. Please contact MCE to confirm these dimensions.2 Capacity requirements: US & Canada (see A17.1/B44, Appendix D)3 Interior dimensions may vary depending on standard interior finish selections

5 Gurney compliance only available on passenger applications using side slide doors. Gurney requirements to be confirmed with inspection authority.

4 For cab heights greater than 8' - 0", add the measurement difference to the OH dimension. 350 fpm example: 9' - 0" minus 8' - 0" = 1' - 0" + 17' 10" = 18' - 10". All overhead heights are clear under anything in the overhead structure.

Machine Room

Hoistway

Passenger Hospital

Car 3

Capacity

Passenger capacity 2

Gurney compliance (24" x 76" or 24" x 84") 5

Door types5

Page 18: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Electrical Requirements and Heat Release18

Speed

Capacity

2100250030003500

3500 F/R4000

H4000H4500H5000

H5000 AIA

Speed

Capacity

2100250030003500

3500 F/R4000

H4000H4500H5000

H5000 AIA

Speed

CapacityControl BTU's

Machine BTU'sControl BTU's

Machine BTU's

2100 7229 1092 7229 10922500 7229 1092 7229 10923000 7229 1092 7229 10923500 7229 1092 7229 1092

3500 F/R 17113 3101 17113 31014000 17113 3101 17113 3101

H4000 17113 3101 17113 3101H4500 17113 3101 17113 3101H5000 17113 3101 17113 3101

H5000 AIA 17113 3101 17113 3101

Speed

CapacityControl BTU's

Machine BTU'sControl BTU's

Machine BTU's

2100 9448 1910 16771 27272500 9448 1910 16771 27273000 9448 1910 16771 27273500 9448 1910 16771 2727

3500 F/R 17113 3101 17113 34074000 17113 3101 17113 3407

H4000 17113 3101 17113 3407H4500 17113 3101 17113 3407H5000 17113 3101 17113 3407

H5000 AIA 17113 3101 17113 3407

Heat Release values are based on BTU's per hour per car.

For Machine Room-Less applications, Machine Heat Release (BTU's) should be added to hoistway heat load.

7682 7682

7682 76827682 7682

7682 76827682 7682

5121 68287682 7682

5121 68285121 6828

Isolation Transformer BTU's Isolation Transformer BTU's

5121 6828

7682 7682

Heat Release

350 FPM 500 FPM

7682 76827682 7682

7682 76827682 7682

3414 34147682 7682

3414 34143414 3414

Isolation Transformer BTU's Isolation Transformer BTU's

3414 3414

All Electrical Requirements and Heat Release values are intended for estimate purposes only. Job specific values must always be confirmed on MCE's "For Construction" Drawings prior to construction.

Heat Release

150 FPM 200 FPM

132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 11490 / 78 / 39 / 31 226 / 195 / 98 / 78 118 / 102 / 51 / 41 295 / 256 / 128 / 10290 / 78 / 39 / 31 226 / 195 / 98 / 78 118 / 102 / 51 / 41 295 / 256 / 128 / 10290 / 78 / 39 / 31 226 / 195 / 98 / 78 118 / 102 / 51 / 41 295 / 256 / 128 / 10290 / 78 / 39 / 31 226 / 195 / 98 / 78 118 / 102 / 51 / 41 295 / 256 / 128 / 102

Electrical Requirements

350 FPM 500 FPM

FLA @ 208/240/480/600 VACAccelerating Amps @ 208/240/480/600 VAC

FLA @ 208/240/480/600 VACAccelerating Amps @ 208/240/480/600 VAC

132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 114132 / 114 / 57 / 46 330 / 286 / 143 / 114 132 / 114 / 57 / 46 330 / 286 / 143 / 11462 / 54 / 27 / 22 156 / 135 / 68 / 54 62 / 54 / 27 / 22 156 / 135 / 68 / 5462 / 54 / 27 / 22 156 / 135 / 68 / 54 62 / 54 / 27 / 22 156 / 135 / 68 / 5462 / 54 / 27 / 22 156 / 135 / 68 / 54 62 / 54 / 27 / 22 156 / 135 / 68 / 5462 / 54 / 27 / 22 156 / 135 / 68 / 54 62 / 54 / 27 / 22 156 / 135 / 68 / 54

Electrical Requirements

150 FPM 200 FPM

FLA @ 208/240/480/600 VACAccelerating Amps @ 208/240/480/600 VAC

FLA @ 208/240/480/600 VACAccelerating Amps @ 208/240/480/600 VAC

Page 19: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

19High Rise Technology for Low and Mid-Rise Applications

Motion 4000

MCE’s innovative MRL Remote Rescue™ incorporates video imaging and battery power to allow a technician to safely move the car to a landing if commercial power is lost. A car-mounted camera sends video to an LCD screen in the controller. Using a button to control battery-provided brake lift power, and watch-ing the LCD, the technician moves the car to a landing, aligning a marker on the LCD with a graphic in the hoistway to stop the car in the landing zone.

MRL Remote Rescue™

With in-house machine and control expertise, MCE teamed up with Imperial Electric, to engineer the best matched motor, control and brake combinations resulting in a wide variety of op-tions in the Freedom™ product line. Use of a dual independently controlled brake system eliminates the need for a rope brake.

iControl MCE’s industry leading Motion 4000 and iControl are the cornerstone of the Freedom™ product line and ensure future serviceability options are the choice of the owner. Being the industry leader for independent elevator control technology, MCE is able to provide state-of-the-art high rise motor control technology in low to mid-rise applications. This results in major performance improvement when compared to controls histori-cally used in the low to mid-rise range.

ACPM Machines

Page 20: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Cabs and Entrances20

Jambs and Doors

MCE’s elevator cabs, entrances and doors are engineered and manufactured to the highest industry

standard. MCE’s entrances carry UL labeling on door panels and jambs. Three piece jambs are

standard. Mitered and welded jambs are optional.

Sill Selection Standard Metal Finishes

Single slide door

Two-speed side slide door

Center opening door Nickel silver

Bronze

Aluminum (standard)

#4 brushed commercial bronze

#8 mirror commercial bronze

#4 brushed 304 stainless steel (standard)

#8 mirror 304 stainless steel

#4 brushed 60/40 muntz/bronze

#8 mirror 60/40 muntz/bronze

Page 21: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

21

MCE’s Freedom™ standard elevator cabs feature removable vertical plastic laminate panels. A variety of pre-selected

fire-rated plastic laminate choices are conveniently listed in this brochure. Optional horizontal or combination vertical/

horizontal panels are also available. Custom cab interiors can also be provided based on your design specifications.

Stainless Steel #4 (standard) Muntz/Bronze #4

Combination Vertical/Horizontal Wall Panels

Horizontal Wall PanelsVertical Wall Panels (standard)

Page 22: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Surfaces22

4783-60 White Tigris

4669-60 Natural Tigris

4673-60 Saffron Tigris

4667-60 Green Tigris

4811-60 Silicon EV

4810-60 Titanium EV

4813-60 Nickel EV

4814-60 Tungsten EV

4820-60 Carbon EV

Fibers

7928-38 Castle Oak

7925-38 Monticello Maple

10745-60 Fonthill Pear

7924K-07* Biltmore Cherry

7922K-07* Brighton Walnut

7909-60 Fusion Maple

10734-60 Limber Maple

7938-38 New Age Oak

7937-38 River Cherry

7947K-18* Rio

7923K-07* Versailles Anigre

7942K-07* Cocobala

Traditional and Exotic Wood Looks

4876-38 Sheer Mesh

4877-38 Grey Mesh

4878-38 Pewter Mesh

4881-38 Copper Mesh

4880-38 Carbon Mesh

4779-60 Pewter Brush

4823-60 Antique Brush

4794-60 Windswept Bronze

4795-60 Windswept Pewter

4860K-07* Silver Alchemy

4861K-07* Gold Alchemy

Metal Looks

4847-38 Mission Smoke

4850-38 Mission Stucco

4853-38 Mission Stone

4848-38 Mission Sage

4854-38 Mission Glaze

4886-38 Pearl Soapstone

4887-38 Tan Soapstone

4885-38 Green Soapstone

4882-38 Oiled Soapstone

4884-38 Flame Soapstone

4888-38 Rustic Slate

Stone Looks

7939K-18* Blond Echo

7941K-18* Tan Echo

7952K-18* Asian Sand

7951K-18* Asian Sun

7949K-18* Asian Night

7944K-01* Madagascar

Linear Wood Looks

MCE complete elevator package options include

fire-rated, environmentally-friendly high-pressure

laminates from world-leading producers of decorative

surfacing products, including Wilsonart®.

Choose from a large selection of styles, colors and design innovations. Many of these Wilsonart® Fire-Rated laminates are GREENGUARD® Indoor Air Quality Certified. The GREENGUARD® Certification ProgramSM is an industry-independent, third-party testing program for low-emitting products and materi-als. To date, more than 100 manufacturers across various industries offer GREENGUARD® Indoor Air Quality Certified Products.

4843-60 Misted Zephyr

4841-60 Desert Zephyr

4858-60 Crisp Zephyr

4859-60 Spiced Zephyr

Abstracts

This is just a representative sample of MCE's surfaces. For a complete list of surface options, please refer to MCE's Standard Finishes brochure.

* Premium products

Page 23: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

23Powder/Paint Coatings*

RAL 2004 49/24530

RAL 2008 49/24340

RAL 2001 49/2456038/23170

RAL 2003 49/24540

RAL 2002 49/24550 38/25002

* Please visit www.tigerdrylac.com to verify colors.

RAL 1000 49/15200 38/15000

RAL 1002 49/22590 38/20002

RAL 1003 49/22580

RAL 1007 49/22540

RAL 1004 49/22570 38/20004

RAL 1005 49/22560 38/20005

RAL 1001 49/15190 38/15001

RAL 6007 49/52860 38/50007

RAL 6008 49/53240 38/50008

RAL 6009 49/52840 38/50009

RAL 6010 49/52830 38/50031

RAL 6011 49/52820 38/50011

RAL 6012 49/51540 38/50012

RAL 1017 49/22510 38/20017

RAL 1018 49/21830 38/20018

RAL 1019 49/13660 38/15019

RAL 1020 49/22500 38/20020

RAL 1023 49/22490 38/20023

RAL 1024 49/22480 38/20024

RAL 1027 49/22470 38/20027

RAL 6020 49/52710 38/50020

RAL 6021 49/52700 38/50021

RAL 6022 49/52690 38/50022

RAL 6024 49/52680 38/50024

RAL 6025 49/52670 38/50025

RAL 6026 49/52660 38/50026

RAL 2010 49/24520 38/25001

RAL 2011 49/24580

RAL 7001 49/72710 38/70003

RAL 7002 49/72720 38/70007

RAL 7003 49/72600 38/70017

RAL 7004 49/73300 38/70004

RAL 7005 49/72590 38/70005

RAL 7006 49/7258038/70006

RAL 3003 49/31100 38/30003

RAL 3004 49/33900 38/30004

RAL 3007 49/31910 38/30007

RAL 3009 49/31920 38/30009

RAL 3011 49/31090 38/30011

RAL 3012 49/31940 38/30012

RAL 3013 49/31950 38/30013

RAL 7016 49/72830 38/70016

RAL 7021 49/72540 38/70021

RAL 7022 49/72850 38/70022

RAL 7023 49/72530 38/70023

RAL 7024 49/72870 38/70024

RAL 7026 49/72880 38/70026

RAL 3027 49/33660

RAL 3031 49/34730 38/30031

RAL 3022 49/33700

RAL 4001 49/43160

RAL 4002 49/31030 38/30008

RAL 4003 49/32270

RAL 4004 49/31020 38/30024

RAL 7037 49/72480 38/70037

RAL 7038 49/72470 38/70038

RAL 7039 49/71020 38/70039

RAL 7040 49/75470 38/70046

RAL 7042 49/73250 38/70042

RAL 7043 49/72460 38/70043

RAL 5000 49/4220038/40000

RAL 5001 49/42210 38/40001

RAL 5002 49/42220 38/40002

RAL 5003 49/42230 38/40003

RAL 5004 49/42240 38/40004

RAL 5005 49/43190 38/40010

RAL 5007 49/42250 38/40007

RAL 8003 49/66140 38/60003

RAL 8004 49/66130 38/60004

RAL 8007 49/66120 38/60007

RAL 8008 49/66110 38/60008

RAL 8011 49/66100 38/60011

RAL 8012 49/66090 38/60012

RAL 5015 49/42330 38/40015

RAL 5017 49/40760 38/40017

RAL 5018 49/41140 38/40020

RAL 5022 49/42390 38/40022

RAL 5021 49/41190 38/40021

RAL 5020 49/44270 38/40018

RAL 5019 49/42360 38/40019

RAL 8024 49/66060 38/60024

RAL 8025 49/66050 38/60025

RAL 8028 49/66500 38/60028

RAL 9001 49/10016 38/10001

RAL 9002 49/70520 38/10002

RAL 9010 49/11500 38/10004

A complete color palette is available in MCE's Standard Finishes brochure.

Page 24: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Fixtures24

Universal — (standard)

All car and hall stations and directional lanterns are available in a wide variety of configurations. Choose from two metal finishes, an array of push button options and more important features than found with any other manufacturer’s standard line of fixtures.

Premier — sophisticated and rugged

Sophisticated, elegant design with the toughness you’d expect from all of our fixtures. Available in rectangular or elliptical faceplate designs with a variety of push button configurations. The Premier Collection will meet the most demanding architectural application requirements.

Prestige — beauty and brawn

The Prestige combines the best of all worlds — an ultra-sleek appearance combined with unsurpassed durability. Add in Innovation’s Multi-Volt technology and wide range of illumination colors and you have the ultimate push button.

Bruiser — heavy duty/vandal resistant

Everything about the Bruiser is designed and manufactured for rugged, unmatched strength and durability. Exclusive push button design virtually eliminates damage to internal studs or contacts.

MCE’s elevator packages feature design-rich, dependable fixtures from Innovation Industries. Highly respected in the elevator

industry, Innovation’s high quality fixtures incorporate the following standard features: Six metals and finishes, ultra-bright

LED illumination in amber, white, red, green or blue, digital position indicators, car station hands-free or cabinet-mounted

telephones, scrolling message display, emergency light, service cabinet, voice annunciator, and project specific engraving.

Car Operating Panels and Hall Stations

Page 25: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

25

Push Buttons

Innovation Industries manufactures a variety of buttons and braille inserts. While it’s not possible to include them all here, you can be assured that every push button device is built to the highest standards of quality to meet or exceed ADA and ASME A17.1 requirements and state and local codes. In addition, every Innovation push button incorporates exclusive Multi-Volt design.

BUTTON STYLE MODEL PROFILE FIXTURE

SERIES DESCRIPTION MATERIAL CALIFORNIA CODE COMPLIANT

PB-1 (Standard) Universal Round, projecting, illuminated,

black halo, white insert Plastic No

PB-2 Universal Round, flush, illuminated, black halo, white insert Plastic No

PB-3 (CA

Standard)Universal Round, illuminated, with flush black halo

and projecting white insert Plastic Yes

PB-4 Universal Square, projecting, illuminated, black halo, white insert Plastic No

PB-5 Universal Square, flush, illuminated, black halo, white insert Plastic No

PB-6 Universal Square, illuminated, with flush black halo and projecting white insert Plastic Yes

PB-21 Premier Round, projecting, illuminated, metalized halo and insert Plastic No

PB-22 Premier Square, projecting, illuminated, metalized halo and insert Plastic No

PB-23 Bruiser Round, projecting, illuminated, with red center jewel, counter-bored stop

Metal No

PB-27 Bruiser Round, projecting, illuminated, with red center jewel, counter-bored stop

Metal Yes

PB-29 Prestige Round, projecting, illuminated,white halo, metal insert

Metal with plastic

haloNo

PB-30 Prestige Round, projecting, with illuminated flush white halo and projecting metal insert

Metal with plastic

haloYes

PB-31 Premier Round, illuminated, with flush metalized halo and projecting metalized insert Plastic Yes

PB-32 Premier Square, illuminated, with flush metalized halo and projecting metalized insert Plastic Yes

PB-33 Premier Round, flush, illuminated, metalized halo and insert Plastic No

PB-34 Premier Square, flush, illuminated, metalized halo and insert Plastic No

AVAILABLE BRAILLE OPTIONS DESCRIPTION

Round, 1.375“ diameter

Square, 1.25” square

Oval surround* (Standard)

* PB-1, PB-2, PB-3, PB-13, PB-21, PB-29, PB-30, PB-31, PB-33, PB-35, PB-36, PB-37,

PB-39, PB-44, PB-45, PB-47 only

For more information, please request MCE's Standard Finishes brochure.

Page 26: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Standard FreedomTM Finishes26

Entrances 7’ – 0” high entrances, UL listed jambs and door panels as required, aluminum sills, stainless steel #4 jamb and door panels, adhesive backed jamb Braille, 1/2" solid bar stock door tops, welded internal ribs with solid door backs

Cab shell 8' - 0" cab height, 14 gauge steel shell, Jetcoat with sound deadening exterior, aluminum car sill

Wall panels Removable ¾” vertical raised panels, fire rated particle board, faced and edge banded with a non-premium plastic laminate from MCE’s pre-selected Wilsonart® plastic laminate selections

Base and reveals Stainless steel #4

Handrail 1 ½” tubular handrail with stainless steel #4 finish located on rear wall for front opening applications and side walls for front and rear applications

Cab front Fixed stainless steel #4 returns, columns and transom

Canopy 12 gauge rolled steel, primer gray exterior, powder coated reflective white, escape hatch flush with canopy, mechanical lock and electric switch

Drop ceiling 14 gauge stainless steel #4 tee bar frame with fluorescent lights over polygal diffuser

Car fixtures Main car operating panel: Hinged stainless steel #4 faceplate, round plastic buttons, digital car position indicator, code required items and engraving as needed

Hall fixtures Hall stations: Flush stainless steel plates with round plastic buttons, code required features and engraving as needed

Cab and entrance options are available including size and finish. Contact your MCE representative for additional options.

Our Freedom™ elevator standard finishes provide cost-effective beauty without sacrificing quality. You're not sacrificing

when you ask for "standard finishes" from MCE.

Page 27: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

27Destination Based Dispatching

MCE’s Destination Based Dispatching

is an innovative dispatching system that

enhances building traffic flow by intelligently

matching passengers to elevator cars and

achieving optimal efficiency.

The technology behind this system uses complex algorithms, but the passenger experience is quite simple: After selecting the desired floor on a touch-screen, passengers are directed to the elevator that will take them to their destination. It’s just that simple.

Everyone familiar with traditional dispatching — where passengers wait impatiently for the first elevator to arrive and then gather at the elevator as the door opens — knows the pressure of catching the next elevator. With Destination Based Dispatching, passengers can relax because they know in advance which elevator is coming to meet them.

Destination Based Dispatching allows the most efficient passenger elevator assignment for a given number of floors, passengers per elevator, and minimum number of stops per elevator. It provides an alternative to the typical busy scenario where a crowd of passengers enters an elevator, each needing to select a floor when they board and then enduring the wait as the elevator stops at several floors — sometimes depositing just one passenger per floor. And this process is duplicated for every elevator in the group. Effective Destination Based Dispatching eliminates this inefficiency by assigning groups of passengers with the same destination to the same elevator, resulting in far fewer stops and improving transit time.

Destination Based Dispatching also provides an ideal solution to minimize expense and maximize effi-ciency during up-peak traffic times. Destination Based Dispatching is used on the lobby floors but standard fixtures and dispatching are used on other floors.

Passenger selects desired floor, then is directed to specific elevator.

Traditional dispatching results in a high mix of destinations per car, requiring more stops and more time.

Destination based dispatching results in a low mix of destinations per car, requiring fewer stops and less time.

MCE Touchscreen Technology

Traffic Handling Benefits

Page 28: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Monitoring and Peripherals28

iMonitor

iReport

MCE’s elevator group monitoring application

iMonitor provides real-time viewing and access — for elevators just across the hall, in multiple buildings across a campus, even multiple sites across the country. iMonitor’s graphical presentation and real-time connectivity provide up-to-the-minute information and allow you to take control if needed.

iMonitor provides general views of multiple elevator groups, hoistway views of multiple cars within a group or detailed views of selected cars. Create “connection sets” to display — each connection set consists of up to fifty connections to elevator group dispatchers, each of which may be at a different physical site.

iMonitor also allows you to configure hall and car call security, enable or disable special group modes of operation, recall a car to a floor you specify, control its door operation at that floor and enable or disable individual car operating modes.

High level multi-group view

Use iMonitor’s high-level views to maintain a broad perspective on several groups simultaneously.

Detailed single-group view

Narrow your attention to cars in a particular elevator group with a click of the mouse.

Comprehensive data storage, data analysis and report generation tool

iReport takes advantage of the intelligence and communicating power designed into iControl elevator controls to automatically collect detailed information about minute-to-minute operation, system events, faults and operating status. iReport is easily configured to automatically contact those maintenance and administrative personnel who need to be advised whenever specific events occur. You can even choose days and times when contact should be initiated.

Page 29: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

29

BMS-Link™

TAPS® (Traction Auxiliary Power Supply)

Integrate MCE control systems into your Building Management System

Powered by Niagara software and developed by Gemini Integration Services and MCE, a simple Web “appliance” interfaces to the elevator or escalator system and provides Web page status display and control to the building management system. For the first time, vertical transportation systems are open to the building management system.

Through BMS-Link™, your management system can place up or down direction hall calls and even tune elevator energy usage by activating any of three different Demand Response levels in reaction to building management system signals — saving energy and money. Cars may be placed out of service. Out of service cars may be returned to service at any time. Elevator system information may be collected over time and used to develop trend data.

Backup power for VVVF controllers

When commercial power is lost, TAPS® safely delivers the elevator car to a landing and maintains door power so passengers can exit. During normal operation, TAPS® builds and maintains reserve energy while continuously monitoring commercial power. TAPS® determines the optimum travel direction (next landing up or down) without requiring a load weighing system, ensuring that energy use is minimized and battery power is conserved for as long as possible. TAPS® features include:

•Onboardcontrollerforintelligentoperation

•RestartinputfromCOPdooropenbutton

•Testbuttontosimulatepowerloss

•Batterysaving“rescuecomplete”inputshutsoffbackuppowerwhen rescue is complete

•User-adjustableparameters

•UPSbypasscontrol

•Monitorsdisconnectswitch

•Lockableshut-offswitchforadditionalsafetywhileworkingontheelevator

CONTROLLERS USERS NETWORKS

LOGOUT

Click here to add a new device +

ADD DEVICE FORM

Name

Model

IP Address

Port

CancelxSave

NAME MODEL IP ADDRESS PORT STATUS VERSION CONFIGURATION LEARN

sim2 iCue 11.38.04.63 4555 Down, Alarm 2.2.1 6 Floors, 2 Cars Learned

sim2 M2000/4000 11.38.03.51 4555 Normal 1.1.0 4 Floors, 2 Cars Learned

sim1 M2000/4000 11.38.02.41 4555 Normal 1.0.0 10 Floors, 2 Cars Learned x

x

x

Page 30: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Work By Others*30

The following preparatory work is required in order to properly install the elevator equipment. The cost of this work

is not included in the elevator proposal, since it is a part of the building construction.

A plumb and legal hoistway, to within one inch of plumb per 100 feet with no dimension smaller than shown on drawings, properly framed and enclosed; and including a pit of proper depth, and a pit ladder for each elevator. Pit floor to support loads shown on drawings. Pit floor to be substantially level. Drains, sump and sump pump, lights, light switches and electrical outlets, access doors, waterproofing, access walks, handrails and hoistway ventilation, as required.

Provide a code compliant control closet or control room with access and ventilation in accordance with all applicable codes and regulations. The control closet or control room shall be maintained at a temperature between 32o F (0o C) and 104o F (40o C). Relative humidity not to exceed 95% non-condensing. Please validate that local codes do not require a tighter temperature range or higher ventilation requirements. If the control loca-tion will exceed these parameters, please contact your MCE representative for control enclosure options. Provide lights, light switches and electrical outlets as required.

Adequate supports for foundations to carry the loads of all equip-ment, including overhead machine and machine beams located in hoistway and supports for guide rail brackets.

Complete three phase connections from the electric power mains to each controller, including necessary circuit breakers and/or fused mainline disconnect switches along with compliant piping and conduit. Materials and installation shall meet all applicable national and local electrical codes.

Single phase 120 VAC power for car lighting and alarm circuit provided to each controller, including necessary circuit breaker and/or fused disconnect switches along with compliant piping and conduit. Materials and installation shall meet all applicable national and local electrical codes.

Temporary power shall be provided without cost to the elevator contractor during construction and shall match all characteristics of the permanent power supply.

Divider beams for rail brackets shall be provided as required by code and design requirements as noted on job specific Shop Drawings.

Cutting of walls, floor, etc. and removal of such obstructions may be necessary for proper installation of the elevator.

* Refer to quote and drawings for additional materials to be supplied by others.

Page 31: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications
Page 32: PLANNING GUIDE - Motion Control Engineering - The leader ... · MRL Planning Guide 6-9 Machine Room 2:1 Planning Guide 10-13 ... 5 Gurney compliance only available on passenger applications

Motion Control EngineeringHeadquarters & Manufacturing11380 White Rock RoadRancho Cordova, CA 95742

916.463.9200 direct800.444.7442 x545 toll [email protected] www.mceinc.com

August 2009

All illustrations, specifications and dimensions are based on information in effect at the time of this publication printing date. Motion Control Engineering reserves the right to change specifications, designs and materials utilized and may discontinue items without prior notice or obligations.