plate & cased axial 2012 web
TRANSCRIPT
-
7/29/2019 Plate & Cased Axial 2012 WEB
1/13
PlateMounted &
Cased AxialFans
2012 Edition
-
7/29/2019 Plate & Cased Axial 2012 WEB
2/13
2 Axair Fans UK Ltd 01782 349 430
...About Axair Fans UK
Application Knowledge:Over 20 years experience in general air movement; including corrosive,explosive and hot fume handling.
Stock Facility:Large modern warehouse facility containing a vast selection of fans, fancomponents and general accessories.
Customised Build:Fans assembled from standard components to create the perfect mechanicaland electrical solution to safe fume extraction.
Customer Care:Experience a sense of partnership with Axair Fans.
Loweld Drive - Centre 500 - Wolstanton - Newcastle-Under-Lyme - ST5 0UUTel: 01782 349430 Fax: 01782 349439 Email: [email protected] www.axair-fans.co.uk
All specications, data and drawings are subject to alterations without prior notice
-
7/29/2019 Plate & Cased Axial 2012 WEB
3/13
General Description
Fan Square plate mounting in sheet steel (HEP) Rolled steel casing (HEPT)
External terminal box with IP65 protection (HEPT) Fan guard with integral motor mounting to DIN and UNE standards Impeller in Polyamide 6 with breglass reinforcement Dynamically balanced to ISO 1940 Zinc phosphate surface treated steel Epoxy resin anti-corrosive nish, kiln dried at 200C
HEP Square plate with 4 xing holes for ease of mounting Folded edge for extra rigidity Bell-mouth inlet for optimum performance Motor supported from a rigid inlet guard
HEPT
Rolled steel case with Standard ange mountings at each end External Terminal box of IP65 protection class Motor supported from a rigid open guard
Motor Squirrel-cage induction motor Three-phase dual voltage connection 230/400V 50Hz Single Phase 230V 50Hz IP65 dust and hosed water protection Class F winding insulation with Class B temperature rise Over-heat protection by self-resetting thermo-contact Permitted air-stream temperatures:
- 2 pole (2800/min) motors -25C up to +45C- 4 pole (1400/min) & 6 pole (930/min) motors -25C up to +60C
Standard Air Flow Direction
From guard to impeller(Reverse air-ow impeller upon request)
HEP-25-2 T / H
Blade angle:Voltage:Number of PolesImpeller Diameter
H: High pitch L: Low pitchM: Single phase T: Three phase2: 2 pole 4: 4 pole 6: 6 pole25: 250 35: 350 45: 450 56: 56031: 315 40: 400 50: 500 63: 630
Fan type: HEP: Plate mounted axialHEPT: Cased axial
Reference Code
-
7/29/2019 Plate & Cased Axial 2012 WEB
4/13
4 Axair Fans UK Ltd 01782 349 430
250 & 315
2 & 4 pole Single & Three Phase
Technical Data
Model
AirowRate
Speed
Max ElectricalSupply
InputPower
SoundLevel (*)
Weight
Curve230V 400V HEP HEPT
m3/h rpm A W dB(A) Kg
HEP-25-2T/H 2300 2780 1.30 0.75 250 64 5.3 -1
HEP-25-2M/H 2300 2750 1.95 - 285 64 5.3 -
HEP-25-4T/H 1250 1450 0.69 0.40 87 52 4.5 -2
HEP-25-4M/H 1250 1440 0.65 - 100 52 4.5 -
HEP-31-2T/H HEPT-31-2T/H 4000 2640 1.54 0.89 495 74 7.0 7.43
HEP-31-2M/H HEPT-31-2M/H 4000 2640 2.30 - 515 74 7.0 7.4
HEP-31-4T/H HEPT-31-4T/H 2400 1410 0.69 0.40 115 55 5.7 6.24
HEP-31-4M/H HEPT-31-4M/H 2400 1410 0.75 140 55 5.7 6.2
(*) NB : Sound level at 3 metres
Airow characteristics
-
7/29/2019 Plate & Cased Axial 2012 WEB
5/13
250 & 315
Plate Mounted
Cased
(mm) A B C DE
F G H2 Pole 4 Pole
HEP-25 330 275 262 260 213 203 11 56 8.5
HEP-31- ... /H 400 336 310.5 308 214 204 11 75 10.5
(mm) A B C D E Number of Holes
HEPT-31 385 355 308 200 10 8
-
7/29/2019 Plate & Cased Axial 2012 WEB
6/13
6 Axair Fans UK Ltd 01782 349 430
350 & 400
2,4 & 6 pole Single & Three Phase
Technical Data
Model
AirowRate
Speed
Max ElectricalSupply
InputPower
SoundLevel (*)
Weight
Curve230V 400V HEP HEPT
m3/h rpm A W dB(A) Kg
HEP-35-2T/H HEPT-35-2T/H 6020 2790 2.16 1.25 650 76 8.8 9.41
HEP-35-2M/H HEPT-35-2M/H 6020 2675 2.80 - 690 76 8.8 9.4
HEP-35-4T/H HEPT-35-4T/H 3500 1340 0.74 0.43 170 58 7.1 7.62
HEP-35-4M/H HEPT-35-4M/H 3500 1340 0.98 - 180 58 7.1 7.6
HEP-40-4T/H HEPT-40-4T/H 5200 1420 2.10 1.20 325 61 10.6 13.53
HEP-40-4M/H HEPT-40-4M/H 5200 1400 1.85 - 360 61 10.6 13.5
HEP-40-6T/H HEPT-40-6T/H 3500 960 1.12 0.65 150 54 10.2 13.54
HEP-40-6M/H HEPT-40-6M/H 3500 960 1.06 - 180 54 10.2 13.5
(*) NB : Sound level at 3 metres
Airow characteristics
-
7/29/2019 Plate & Cased Axial 2012 WEB
7/13
350 & 400
Plate Mounted
Cased
(mm) A B C D E F G H2 Pole 4 Pole 6 Pole
HEP-35-/H 390 465 362.5 360 241 211 - 11 86 10.5
HEP-40-.../H 452 532 412.5 410 - 226 205 11 97.5 10.5
(mm) A B C D E Number of Holes
HEPT-35 425 395 360 220 10 8
HEPT-40 490 450 410 220 10 8
-
7/29/2019 Plate & Cased Axial 2012 WEB
8/13
8 Axair Fans UK Ltd 01782 349 430
450 & 500
4 & 6 pole Single & Three Phase
Technical Data
Model
AirowRate
SpeedMax Electrical
SupplyInputPower
SoundLevel (*)
Weight
Curve230V 400V HEP HEPT
m3/h rpm A W dB(A) Kg
HEP-45-4T/H HEPT-45-4T/H 7300 1400 2.11 1.22 470 66 12.5 15.51
HEP-45-4M/H HEPT-45-4M/H 7300 1400 2.35 - 480 66 12.5 15.5
HEP-45-6T/H HEPT-45-6T/H 4900 955 1.42 0.82 210 56 11.4 15.52
HEP-45-6M/H HEPT-45-6M/H 4900 955 1.40 - 225 56 11.4 15.5
HEP-50-4T/H HEPT-50-4T/H 10150 1420 3.10 1.80 720 69 15.0 18.03
HEP-50-4M/H HEPT-50-4M/H 10150 1380 3.45 - 720 69 15.0 18.0
HEP-50-6T/H HEPT-50-6T/H 6150 950 1.38 0.80 240 59 13.2 18.04
HEP-50-6M/H HEPT-50-6M/H 6150 950 1.38 - 245 59 13.2 18.0
(*) NB : Sound level at 3 metres
Airow characteristics
-
7/29/2019 Plate & Cased Axial 2012 WEB
9/13
450 & 500
Plate Mounted
Cased
(mm) A B C D E F G H4 Pole 6 Pole
HEP-45-/H 504 596 462.5 460 234 218 11 105 10.5
HEP-50-.../H 562 665 516.5 514 275 254 11 115 10.5
(mm) A B C D E Number of Holes
HEPT-45 540 500 460 220 12 8
HEPT-50 600 560 514 230 12 12
-
7/29/2019 Plate & Cased Axial 2012 WEB
10/13
10 Axair Fans UK Ltd 01782 349 430
560 & 630
4 & 6 pole Single & Three Phase
Technical Data
Model
AirowRate
Speed
Max ElectricalSupply
InputPower
SoundLevel (*)
Weight
Curve230V 400V HEP HEPT
m3/h rpm A W dB(A) Kg
HEP-56-4T/H HEPT-56-4T/H 12800 1350 3.63 2.10 1050 72 21.0 28.01
HEP-56-4M/H HEPT-56-4M/H 12800 1350 5.26 - 1060 72 21.0 28.0
HEP-56-6T/H HEPT-56-6T/H 8250 915 1.73 1.00 400 62 17.0 28.02
HEP-56-6M/H HEPT-56-6M/H 8250 915 2.25 - 415 62 17.0 28.0
HEP-63-4T/H HEPT-63-4T/H 18700 1415 6.92 4.00 1700 82 25.8 33.5 3HEP-63-4T/L 16500 1375 5.01 2.90 1290 75 23.0 -
4HEP-63-4M/L HEPT-63-4M/L 16500 1375 5.40 - 1295 75 23.0 31.0
HEP-63-6T/H HEPT-63-6T/H 12050 905 2.06 1.19 500 65 20.2 33.55
HEP-63-6M/H HEPT-63-6M/H 12050 905 2.70 - 560 65 20.2 33.5
(*) NB : Sound level at 3 metres
Airow characteristics
-
7/29/2019 Plate & Cased Axial 2012 WEB
11/13
560 & 630
Plate Mounted
Cased
(mm) A B C D E F G H4 Pole 6 Pole
HEP-56- ... 710 630 563 560 306 266 15 115 10.5
HEP-63- ... 800 710 638 635 360 276 15 140 10.5
HEP-63- ... /L 800 710 638 635 360 266 15 140 10.5
(mm) A B C D E Number of Holes
HEPT-56 660 620 560 260 12 12
HEPT-63 730 690 635 280 12 12
-
7/29/2019 Plate & Cased Axial 2012 WEB
12/13
Accessories
Ancillary Pack(For HEPT - Long Cased Axial Fan)
Includes : 2 Matching anges (a) 2 exible couplings (b) 1 pair of mounting brackets (c) 4 AV mountings 4 Fixing clips
Also Available:
ElectricalIsolator
Gravity LouvreShutter
ElectronicSpeed Regulator
FingerGuard
-
7/29/2019 Plate & Cased Axial 2012 WEB
13/13
Loweld DriveCentre 500Wolstanton
Newcastle-Under-LymeST5 0UU
Tel: 01782 349430Fax: 01782 349439
Email: [email protected]