3 Updated Requirements Technical Issue – Linkage DM 1.1 DM 1.2 DM 1.3 Chillers Duct 1 Chiller 2 Duct 2 HVAC Sys Drawing2 DM 2.3 DM 2.2 HVAC Sys IETM 1 HVAC Sys IETM 2 ISEA IDE (Radar) DM 1.1 DM 1.2 Mod 1 Radar IETM Mod 1 DM 1.3 Mod 2 DM 2.1 Mod 2 Radar IETM DM 2.2 Chiller 1 HVAC Sys HVAC Ducts HVAC Sys Drawing1 Shipyard Design & IDETRANSCRIPT
![Page 1: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/1.jpg)
PLCS and S1000D Technical Issues
![Page 2: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/2.jpg)
2
ISE 6 Phase 2 Technical Issues
• S1000D PLCS DEX– Need to exchange S1000D data modules and relationships to
product model– Listed under Business DEX section of plcs-resources
• But non content defined
• Linkage between product data and data modules– If design change occurs, need to identify the data modules (TM
and training) affected so they can be reviewed and updated.
![Page 3: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/3.jpg)
3Updated
Requirements
Technical Issue – Linkage
DM 1.1
DM 1.2
DM 1.3
Chillers
Duct 1
Chiller 2
Duct 2
HVAC SysDrawing2
DM 2.3
DM 2.2
HVAC SysIETM 1
HVAC SysIETM 2
ISEA IDE (Radar)
DM 1.1
DM 1.2Mod 1RadarIETM
Mod 1
DM 1.3Mod 2
DM 2.1
Mod 2RadarIETM
DM 2.2
Chiller 1
HVAC Sys
HVAC Ducts
HVAC SysDrawing1
Shipyard Design & IDE
![Page 4: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/4.jpg)
4
Linkage• If design change occurs, need to identify the data modules (TM and
training) affected so they can be reviewed and updated.– 1. Create Ship Alt
• Identify affected support systems• Identify affected components
– 2. List DM related to affected components– Need mechanism to link a DM to equipment.
• Can’t always rely on DMC to provide linkage– Data modules may have been authored by vendor or other program– May utilize different business rules (applied at time of creation, not use)
• Must be relationship – – DMC is generated based on business rules in effect at the time DM was
created– Example – pump TM generated for carrier, reused on DDG
– Assume dual use DM used to manage training and tech pubs
![Page 5: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/5.jpg)
5
EuroSTEP Approach
![Page 6: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/6.jpg)
6
Linkage• Equipment level TM
– PM linked to piece of equipment– TDMIS would related PMC to APL
• System level TM– PM linked to system– Individual DM linked to equipment/components within system
• DM where used– Need to derive inverse relationship from PM– LSAR – already maintains relationships
![Page 7: PLCS and S1000D Technical Issues. 2 ISE 6 Phase 2 Technical Issues S1000D PLCS DEX Need to exchange S1000D data modules and relationships to product](https://reader036.vdocument.in/reader036/viewer/2022081804/5a4d1b687f8b9ab0599b22fb/html5/thumbnails/7.jpg)
7
Questions / Issues• Linkage for DMC, PMC to product structure
– DDG 1000 linker must identify linkage
• GIA 0007