pls-cadd drawing north - n 2016-0411... · pdf filepls-cadd drawing-0 100200...
TRANSCRIPT
PLS-CADD Drawing
-0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
10
20
30
40
50
PI 0°00'00"
PI 64°54'48"
1 t-e
xist
sta
=0
.0
0
ht=
18
.3
0 e
le
=2
7.2
0
87.12
PI -26°56'44"
2 radt65°
sta
=8
7.1
2
ht=
16
.2
0 e
le
=2
1.8
8
3 rrd
te
sta
=1
54
.1
2
ht=
13
.5
0 e
le
=2
2.5
1
67.00
133.01
4 radt27°
sta
=2
87
.1
3
ht=
18
.9
0 e
le
=2
4.4
2
5 a
dt
sta
=4
40
.1
3
ht=
18
.0
0 e
le
=2
3.8
0
6 a
dt+
1
sta
=5
97
.1
3
ht=
18
.9
0 e
le
=2
5.6
8
7 a
dt+
2
sta
=7
47
.1
3
ht=
19
.8
0 e
le
=3
0.7
5
8 a
dt+
2
sta
=9
02
.1
3
ht=
19
.8
0 e
le
=2
8.9
1
9 a
dt+
1
sta
=1
06
2.1
3
ht=
18
.9
0 e
le
=2
4.5
1
10
a
dt+
2
sta
=1
22
2.1
3
ht=
19
.8
0 e
le
=2
1.9
1
11
a
dt+
2
sta
=1
34
8.1
3
ht=
19
.8
0 e
le
=2
6.6
9
153.00
157.00
150.00 155.00
160.00
160.00
126.00
E
.T
. S
a
lto
G
ra
n
d
e
L
i
n
e
a
1
3
2
k
V
Lin
ea 1
32kV
C
a
m
in
o
LA
T 500kV
LA
T 500kV
Cañada
C
a
m
i
n
o
C
a
m
i
n
o
C
a
m
i
n
o
PI 0.00
0°00'00"
PI 87.12
64°54'48"
PI 287.13
-26°56'44"
1 2 3 4 5 6 7 8 9 10 11
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
N
o
r
t
h
N
o
r
t
h
N
orth
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 1 de 11
10
20
30
40
50
PLS-CADD Drawing
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
10
20
30
40
50
PI 14°51'21"
11
a
dt+
2
sta
=1
34
8.1
3
ht=
19
.8
0 e
le
=2
6.6
9
12
a
dt+
1
sta
=1
50
1.1
3
ht=
18
.9
0 e
le
=3
0.9
5
13
a
dt+
1
sta
=1
64
3.1
3
ht=
18
.9
0 e
le
=3
1.1
2
14
a
dt-1
sta
=1
78
5.1
3
ht=
17
.1
0 e
le
=2
7.4
7
15
a
dt
sta
=1
92
7.1
3
ht=
18
.0
0 e
le
=2
4.3
9
16
a
dt-1
e
sta
=2
06
9.1
3
ht=
17
.1
0 e
le
=2
0.3
4
153.00
142.00 142.00
142.00
142.00
143.78
PI -47°15'28"
FFCC
17 racfdt15º
sta
=2
21
2.9
1
ht=
19
.8
0 e
le
=2
1.8
5
18
rcfd
t
sta
=2
25
2.5
0
ht=
19
.8
0 e
le
=2
2.0
0
19
a
ud
t-1
sta
=2
35
2.5
0
ht=
15
.3
0 e
le
=2
1.8
4
20
a
ud
t
sta
=2
45
2.5
0
ht=
16
.2
0 e
le
=2
0.9
5
21
a
ud
t
sta
=2
55
2.5
0
ht=
16
.2
0 e
le
=2
1.0
9
39.59
100.00
100.00100.00
88.86
22 radtm47°
sta
=2
64
1.3
6
ht=
25
.2
0 e
le
=2
0.2
5
237.42
C
a
m
in
o
C
a
m
i
n
o
C
a
m
i
n
o
Calle Publica
FFCC
FFCC
FFCC
PI 2212.91
14°51'21"
PI 2641.36
-47°15'28"
12 13 14 15 16 17 18 19 20 21 22
N
orth
N
o
r
t
h
N
o
r
t
h
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 2 de 11
ZONA A BALIZAR
10
20
30
40
50
PLS-CADD Drawing
2800
2900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
4000
4100
10
20
30
40
50
PI 36°22'51"
23
rrd
t+
8.5
sta
=2
87
8.7
8
ht=
27
.0
0 e
le
=1
6.2
8
237.42
253.10
24 radt36º
sta
=3
13
1.8
8
ht=
22
.5
0 e
le
=1
3.2
9
25
sd
t+
2
sta
=3
33
6.8
8
ht=
23
.4
e
le
=1
3.0
0
26
sd
t
sta
=3
54
1.8
8
ht=
21
.6
0 e
le
=1
3.9
6
27
sd
t
sta
=3
74
6.8
8
ht=
21
.6
0 e
le
=1
4.6
3
28
rrd
tcve
sta
=3
95
1.8
8
ht=
25
.2
0 e
le
=1
8.0
8
29
a
ud
tcv+
1
sta
=4
05
9.8
8
ht=
22
.5
0 e
le
=1
6.4
8
205.00
108.00
108.00
R
U
T
A
P
R
O
V
.
N
°
1
5
a
C
o
n
c
o
r
d
i
a
E
x
. R
u
ta
N
°1
4
a
C
o
n
c
o
rd
ia
LMT 7,6kV
PI 3131.88
36°22'51"
23 24 25 26 27 28 29 30
N
o
r
t
h
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 3 de 11
205.00 205.00
205.00
10
20
30
40
50
PLS-CADD Drawing
4200
4300
4400
4500
4600
4700
4800
4900
5000
5100
5200
5300
5400
5500
10
20
30
40
50
PI -89°51'03"
30
a
ud
tcv
sta
=4
16
7.8
8
ht=
21
.6
0 e
le
=1
7.2
9
31
a
ud
tcv+
1
sta
=4
27
5.8
8
ht=
22
.5
0 e
le
=1
8.9
1
32
a
ud
tcv
sta
=4
38
5.8
8
ht=
21
.6
0 e
le
=1
9.3
9
33
a
ud
tcv
sta
=4
49
0.8
8
ht=
21
.6
0 e
le
=2
0.1
2
34
a
ud
tcv+
1
sta
=4
59
8.6
1
ht=
22
.5
0 e
le
=2
7.4
8
35
a
ud
tcv
sta
=4
69
3.6
1
ht=
21
.6
0 e
le
=2
6.2
7
36
a
ud
tcv+
1
sta
=4
79
8.6
1
ht=
22
.5
0 e
le
=2
6.9
1
37
a
ud
tcv+
2
sta
=4
89
4.6
2
ht=
23
.4
0 e
le
=2
6.2
6
38
a
ud
tcv
sta
=4
99
8.6
2
ht=
21
.6
0 e
le
=2
9.4
8
39
a
ud
tcv
sta
=5
09
8.6
2
ht=
21
.6
0 e
le
=2
8.2
7
40
a
ud
tcv+
1
sta
=5
19
8.6
2
ht=
22
.5
0 e
le
=2
6.0
8
41
a
ud
tcv
sta
=5
29
8.6
2
ht=
21
.6
0 e
le
=2
2.9
9
42
a
ud
tcv
sta
=5
40
2.6
2
ht=
21
.6
0 e
le
=2
2.5
2
43
a
ud
tcv
sta
=5
49
8.6
2
ht=
21
.6
0 e
le
=2
2.1
5
108.00 110.00
105.00
107.73 95.00
105.00
96.01
104.00 100.00
100.00
100.00
104.00
96.00
98.15
Ca
lle
P
ub
lica
Calle Publica
Calle Publica
ce
rra
da
LMT 7,6kV
LB
T
PI 5596.77
-89°51'03"
30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 4 de 11
10
20
30
40
50
PLS-CADD Drawing
5600
5700
5800
5900
6000
6100
6200
6300
6400
6500
6600
6700
6800
6900
10
20
30
40
50
PI -89°51'03"
98.15
44
rra
dtcv9
0
sta
=5
59
6.7
7
ht=
23
.4
0 e
le
=2
2.5
6
45
a
ue
sta
=5
72
0.7
7
ht=
16
.2
0 e
le
=2
1.4
2
46
a
ue
+1
sta
=5
84
0.7
7
ht=
17
.1
0 e
le
=2
0.3
3
47
a
ue
+3
sta
=5
96
2.7
7
ht=
18
.9
0 e
le
=1
9.2
3
48
a
ue
+3
sta
=6
11
6.7
7
ht=
18
.9
0 e
le
=1
9.9
5
49
a
u
sta
=6
21
8.2
7
ht=
16
.2
0 e
le
=2
2.3
2
50
a
u
sta
=6
31
9.7
7
ht=
16
.2
0 e
le
=2
4.4
9
51
a
u
sta
=6
42
1.2
7
ht=
16
.2
0 e
le
=2
6.6
7
52
a
u
sta
=6
52
2.7
7
ht=
16
.2
0 e
le
=2
8.8
6
53
a
u
sta
=6
62
4.7
7
ht=
16
.2
0 e
le
=3
1.0
6
54
a
u
sta
=6
72
5.7
7
ht=
16
.2
0 e
le
=3
2.4
1
55
a
u-1
sta
=6
82
7.2
7
ht=
15
.3
0 e
le
=3
3.1
8
56
a
u
sta
=6
92
8.7
7
ht=
16
.2
0 e
le
=3
5.2
6
124.00
120.00
122.00
154.00 101.50
101.50
101.50
101.50
102.00
101.00 101.50
101.50
101.50
BD
E
BD
E
BD
E
PI 5596.77
-89°51'03"
44 45 46 47 48 49 50 51 52 53 54 55 56
N
o
rth
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 5 de 11
10
20
30
40
50
PLS-CADD Drawing
7000
7100
7200
7300
7400
7500
7600
7700
7800
7900
8000
8100
8200
8300
30
40
50
60
70
PI -0°08'31"
56
a
u
sta
=6
92
8.7
7
ht=
16
.2
0 e
le
=3
5.2
6
57
a
u
sta
=7
03
0.2
7
ht=
16
.2
0 e
le
=3
8.2
8
58
a
u
sta
=7
13
1.7
7
ht=
16
.2
0 e
le
=3
9.2
2
101.50
101.50
112.52
59
rru
+3
sta
=7
24
4.2
9
ht=
20
.2
5 e
le
=3
9.8
0
60
a
u
sta
=7
34
4.2
9
ht=
16
.2
0 e
le
=3
9.8
9
61
a
u
sta
=7
44
4.2
9
ht=
16
.2
0 e
le
=3
9.9
8
62
a
u-1
sta
=7
54
4.2
9
ht=
15
.3
0 e
le
=4
0.0
8
63
a
u
sta
=7
64
4.2
9
ht=
16
.2
0 e
le
=4
0.1
7
64
a
u
sta
=7
74
4.2
9
ht=
16
.2
0 e
le
=4
0.7
0
65
a
u+
1
sta
=7
84
4.2
9
ht=
17
.1
0 e
le
=4
1.4
4
66
a
u
sta
=7
94
4.2
9
ht=
16
.2
0 e
le
=4
2.2
2
67
a
u
sta
=8
03
9.2
9
ht=
16
.2
0 e
le
=4
2.6
2
68
a
u
sta
=8
14
4.2
9
ht=
16
.2
0 e
le
=4
3.0
6
69
a
u
sta
=8
24
4.2
9
ht=
16
.2
0 e
le
=4
3.4
8
70
a
u
sta
=8
34
4.2
9
ht=
16
.2
0 e
le
=4
3.9
0
100.00
100.00 100.00
100.00
100.00
100.00 100.00
95.00
105.00
100.00
100.00B
AN
QU
IN
A
BA
NQ
UIN
A
PI 7244.29
-0°08'31"
57 58 59 60 61 62 63 64 65 66 67 68 69 70
N
o
rth
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 6 de 11
30
40
50
60
70
PLS-CADD Drawing
8400
8500
8600
8700
8800
8900
9000
9100
9200
9300
9400
9500
9600
9700
9800
40
50
60
70
80
70
a
u
sta
=8
34
4.2
9
ht=
16
.2
0 e
le
=4
3.9
0
71
a
u
sta
=8
44
4.2
9
ht=
16
.2
0 e
le
=4
4.3
2
72
a
u
sta
=8
54
4.2
9
ht=
16
.2
0 e
le
=4
4.7
4
73
a
u+
2
sta
=8
64
4.2
9
ht=
18
.0
0 e
le
=4
5.1
6
74
a
u+
3
sta
=8
74
4.2
9
ht=
18
.9
0 e
le
=4
4.9
3
75
a
u
sta
=8
84
3.2
9
ht=
16
.2
0 e
le
=4
4.5
8
76
a
u
sta
=8
94
2.2
9
ht=
16
.2
0 e
le
=4
6.7
7
77
a
u
sta
=9
04
0.2
9
ht=
16
.2
0 e
le
=4
8.4
6
78
a
u-1
sta
=9
13
8.2
9
ht=
15
.3
0 e
le
=4
7.6
7
79
a
u
sta
=9
23
6.2
9
ht=
16
.2
0 e
le
=4
6.8
7
80
a
u
sta
=9
33
6.2
9
ht=
16
.2
0 e
le
=4
7.4
1
81
a
u
sta
=9
43
6.2
9
ht=
16
.2
0 e
le
=4
8.0
5
82
a
u-1
sta
=9
53
6.2
9
ht=
15
.3
0 e
le
=4
8.5
1
83
a
u
sta
=9
63
6.2
9
ht=
16
.2
0 e
le
=4
8.9
8
84
rru
sta
=9
73
6.2
9
ht=
17
.5
5 e
le
=4
9.4
4
100.00
100.00
100.00
100.00 99.00
99.00
98.00 98.00
98.00
100.00
100.00 100.00
100.00
100.00 100.00
71 72 73 74 75 76 77 78 79 80 81 82 83 84
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 7 de 11
40
50
60
70
80
PLS-CADD Drawing
9800
9900
10000
10100
10200
10300
10400
10500
10600
10700
10800
10900
11000
11100
11200
30
40
50
60
70
85
a
u
sta
=9
83
6.2
9
ht=
16
.2
0 e
le
=4
9.9
1
86
a
u
sta
=9
93
6.2
9
ht=
16
.2
0 e
le
=5
0.3
7
87
a
u
sta
=1
00
36
.2
9
ht=
16
.2
0 e
le
=5
0.0
3
88
a
u-1
sta
=1
01
36
.2
9
ht=
15
.3
0 e
le
=4
9.4
3
89
a
u
sta
=1
02
36
.2
9
ht=
16
.2
0 e
le
=4
8.8
2
90
a
u-1
sta
=1
03
36
.2
9
ht=
15
.3
0 e
le
=4
8.2
2
91
a
u
sta
=1
04
36
.2
9
ht=
16
.2
0 e
le
=4
7.6
2
92
a
u+
3
sta
=1
05
36
.2
9
ht=
17
.4
0 e
le
=4
7.0
1
93
a
u+
3
sta
=1
06
36
.2
9
ht=
16
.9
0 e
le
=4
6.3
1
94
a
u+
4
sta
=1
07
36
.2
9
ht=
18
.3
0 e
le
=4
1.8
9
95
a
u+
4
sta
=1
08
35
.2
9
ht=
19
.8
0 e
le
=3
9.3
8
96
a
u+
2
sta
=1
09
35
.2
9
ht=
18
.0
0 e
le
=3
8.0
8
97
a
u+
2
sta
=1
10
34
.2
9
ht=
18
.0
0 e
le
=3
8.0
6
98
a
u-1
sta
=1
11
32
.2
9
ht=
15
.3
0 e
le
=3
4.2
4
99
a
u
sta
=1
12
31
.2
9
ht=
16
.2
0 e
le
=3
1.8
2
100.00
100.00 100.00
100.00
100.00 100.00
100.00
100.00 100.00
100.00
99.00
100.00
99.00 98.00
99.00
BA
JO
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
Pie de
talud
85 86 87 88 89 90 91 92 93 94 95 96 97 98 99
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 8 de 11
FUNDAR A NIVEL DE CALLE
30
40
50
60
70
PLS-CADD Drawing
11300
11400
11500
11600
11700
11800
11900
12000
12100
12200
12300
12400
12500
12600
30
40
50
60
70
PI 23°35'19"
99
a
u
sta
=1
12
31
.2
9
ht=
16
.2
0 e
le
=3
1.8
2
10
0 a
u
sta
=1
13
30
.2
9
ht=
16
.2
0 e
le
=3
1.8
9
10
1 a
u
sta
=1
14
29
.2
9
ht=
16
.2
0 e
le
=3
1.9
8
10
2 a
u
sta
=1
15
28
.2
9
ht=
16
.2
0 e
le
=3
4.0
3
10
3 a
u
sta
=1
16
27
.2
9
ht=
16
.2
0 e
le
=3
6.0
8
10
4 a
u
sta
=1
17
26
.2
9
ht=
16
.2
0 e
le
=3
9.0
4
10
5 a
u+
4
sta
=1
18
16
.2
9
ht=
19
.8
0 e
le
=4
1.9
0
10
6 a
u-1
sta
=1
19
16
.2
9
ht=
15
.3
0 e
le
=4
0.4
7
10
7 a
u-1
sta
=1
20
07
.2
9
ht=
15
.3
0 e
le
=3
9.3
4
10
8 a
u
sta
=1
21
02
.7
9
ht=
16
.2
0 e
le
=3
8.5
3
10
9 a
u-1
sta
=1
21
98
.2
9
ht=
15
.3
0 e
le
=3
7.9
2
99.0099.00
99.00
99.00
99.00
90.00 100.00
91.00
95.50 95.50
94.71
PI -23°32'41"
110 rau24°+5
sta
=1
22
93
.0
0
ht=
22
.0
5 e
le
=3
8.8
3
49.79
111 rau24°+4
sta
=1
23
42
.7
9
ht=
21
.1
5 e
le
=4
0.1
4
11
2 a
u-1
sta
=1
24
32
.2
9
ht=
15
.3
0 e
le
=4
1.6
9
11
3 a
u
sta
=1
25
21
.7
9
ht=
16
.2
0 e
le
=4
2.7
6
11
4 a
u
sta
=1
26
11
.2
9
ht=
16
.2
0 e
le
=4
1.1
6
89.50
89.50 89.50
TE
MP
.
14°C
PI 12293.00
23°35'19"
PI 12342.79
-23°32'41"
99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114
N
o
rth
N
o
r
t
h
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 9 de 11
30
40
50
60
70
PLS-CADD Drawing
12600
12700
12800
12900
13000
13100
13200
13300
13400
13500
13600
13700
13800
13900
14000
30
40
50
60
70
PI -90°00'39"
11
4 a
u
sta
=1
26
11
.2
9
ht=
16
.2
0 e
le
=4
1.1
6
11
5 a
u-1
sta
=1
27
00
.7
9
ht=
15
.3
0 e
le
=4
0.0
8
11
6 a
u+
5
sta
=1
27
90
.2
9
ht=
20
.7
0 e
le
=3
9.0
0
11
7 a
u
sta
=1
28
82
.7
9
ht=
16
.2
0 e
le
=3
9.8
4
11
8 a
u
sta
=1
29
75
.2
9
ht=
16
.2
0 e
le
=4
1.8
2
11
9 a
u
sta
=1
30
67
.7
9
ht=
16
.2
0 e
le
=4
3.8
1
12
0 a
u-1
sta
=1
31
60
.2
9
ht=
15
.3
0 e
le
=4
6.2
6
12
1 a
u
sta
=1
32
52
.7
9
ht=
16
.2
0 e
le
=5
0.2
6
12
2 a
u-1
sta
=1
33
45
.2
9
ht=
15
.3
0 e
le
=4
9.6
5
12
3 a
u+
1
sta
=1
34
43
.7
9
ht=
17
.1
0 e
le
=4
9.5
3
12
4 rrch
+1
sta
=1
35
31
.5
9
ht=
15
.3
0 e
le
=4
7.5
4
12
5 rrch
+0
.5
sta
=1
35
91
.5
9
ht=
14
.8
5 e
le
=4
5.7
3
89.50
89.50 92.50
92.50
92.50
92.50
92.50 92.50
98.50 87.80
60.00
125.20
12
6 ra
m9
0+
12
.5
sta
=1
37
16
.7
9
ht=
27
.0
0 e
le
=4
3.6
1
12
7 a
u+
1
sta
=1
38
14
.7
9
ht=
17
.1
0 e
le
=4
7.4
6
12
8 a
u
sta
=1
39
12
.7
9
ht=
16
.2
0 e
le
=4
6.3
9
12
9 a
u
sta
=1
40
10
.7
9
ht=
16
.2
0 e
le
=4
6.6
5
98.00
98.00
98.00
PI 13716.79
-90°00'39"
114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129
N
o
rth
N
o
rth
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 10 de 11
30
40
50
60
70
PLS-CADD Drawing
14000
14100
14200
14300
14400
14500
14600
14700
14800
14900
15000
30
40
50
60
70
PI -10°02'02"
12
9 a
u
sta
=1
40
10
.7
9
ht=
16
.2
0 e
le
=4
6.6
5
13
0 a
u
sta
=1
41
08
.7
9
ht=
16
.2
0 e
le
=4
6.5
7
13
1 a
u-1
sta
=1
42
06
.7
9
ht=
15
.3
0 e
le
=4
5.9
3
13
2 a
u
sta
=1
43
04
.7
9
ht=
16
.2
0 e
le
=4
6.3
9
13
3 a
u-1
sta
=1
44
03
.7
9
ht=
15
.3
0 e
le
=4
6.1
5
13
4 a
u
sta
=1
45
02
.7
9
ht=
16
.2
0 e
le
=4
7.4
3
13
5 a
u
sta
=1
46
01
.7
9
ht=
16
.2
0 e
le
=4
7.1
1
13
6 a
u
sta
=1
47
02
.7
9
ht=
16
.2
0 e
le
=4
6.8
7
13
7 a
u+
1
sta
=1
47
94
.7
9
ht=
17
.1
0 e
le
=4
1.7
4
13
8 a
u+
1
sta
=1
48
92
.7
9
ht=
17
.1
0 e
le
=3
9.5
1
98.00
98.00
98.00 99.00
99.00
99.00
101.00
92.00
98.00
100.88
PI 0°00'00"
Term
inal frente a P
ortico
13
9 ra
u1
2+
2
sta
=1
49
93
.6
7
ht=
19
.3
5 e
le
=3
7.9
7
14
0 t
sta
=1
50
79
.6
5
ht=
18
.0
0 e
le
=3
7.9
7
85.98
Calle Los Tilos
Gu
ale
gu
ay
Ca
lle
T
ala
Ca
lle
Dia
ma
nte
Calle Los Tilos
Linea 33kV
E
.T
. C
o
n
c
o
rd
ia
PI 14993.67
-10°02'02"
PI 15078.97
0°00'00"
129 130 131 132 133 134 135 136 137 138 139 140
N
o
rth
North
Plano N°: L002
Planialtimetría
Salto Grande - Concordia II
LAT: Salto Grande-Concordia II
Conductor: ACSR 300/50 mm2
Hilo de Guardia: OPGW 24 fibras
Vert. Scale
Horiz. Scale
2.5 m
20.0 m
LAT 132 kV
EJE DE PROYECTO LAT 132 kV
SOPORTE DE SUSPENSION
LBT
LMT 33 kV
VERTICE
FFCC
ALAMBRADOS
ARROYOS
CAMINOS
LMT 13,2 kV
LEAT 500 kV
ARBOLES
GASODUCTO
LAT 132 kV existente
TELÉFONO
LMT 7,6 kV
REFERENCIAS
Hoja 11 de 11