pls-cadd drawing north - n 2016-0411... · pdf filepls-cadd drawing-0 100200...

11
PLS-CADD Drawing -0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 10 20 30 40 50 3, 3, 1 t-exist sta=0.00 ht=18.30 ele=27.20 87.12 3, UDGW sta=87.12 ht=16.20 ele=21.88 3 rrdte sta=154.12 ht=13.50 ele=22.51 67.00 133.01 UDGW sta=287.13 ht=18.90 ele=24.42 5 adt sta=440.13 ht=18.00 ele=23.80 6 adt+1 sta=597.13 ht=18.90 ele=25.68 7 adt+2 sta=747.13 ht=19.80 ele=30.75 8 adt+2 sta=902.13 ht=19.80 ele=28.91 9 adt+1 sta=1062.13 ht=18.90 ele=24.51 10 adt+2 sta=1222.13 ht=19.80 ele=21.91 11 adt+2 sta=1348.13 ht=19.80 ele=26.69 153.00 157.00 150.00 155.00 160.00 160.00 126.00 E.T. Salto Grande Linea132kV Linea 132kV Camino LAT 500kV LAT 500kV &DxDGD Camino Camino Camino PI 0.00 PI 87.12 PI 287.13 1 2 3 4 5 6 7 8 9 10 11 5QFST 3k 1 5QFSNFQYNRJYWF Salto Grande - Concordia II LAT: Salto Grande-Concordia II Conductor: ACSR 300/50 mm2 Hilo de Guardia: OPGW 24 fibras Vert. Scale Horiz. Scale 2.5 m 20.0 m North North North LAT 132 kV EJE DE PROYECTO LAT 132 kV SOPORTE DE SUSPENSION LBT LMT 33 kV VERTICE FFCC ALAMBRADOS ARROYOS CAMINOS LMT 13,2 kV LEAT 500 kV ARBOLES GASODUCTO LAT 132 kV existente 7(/e)212 LMT 7,6 kV REFERENCIAS Hoja 1 de 11

Upload: trinhnhu

Post on 01-Feb-2018

264 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

PLS-CADD Drawing

-0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

10

20

30

40

50

PI 0°00'00"

PI 64°54'48"

1 t-e

xist

sta

=0

.0

0

ht=

18

.3

0 e

le

=2

7.2

0

87.12

PI -26°56'44"

2 radt65°

sta

=8

7.1

2

ht=

16

.2

0 e

le

=2

1.8

8

3 rrd

te

sta

=1

54

.1

2

ht=

13

.5

0 e

le

=2

2.5

1

67.00

133.01

4 radt27°

sta

=2

87

.1

3

ht=

18

.9

0 e

le

=2

4.4

2

5 a

dt

sta

=4

40

.1

3

ht=

18

.0

0 e

le

=2

3.8

0

6 a

dt+

1

sta

=5

97

.1

3

ht=

18

.9

0 e

le

=2

5.6

8

7 a

dt+

2

sta

=7

47

.1

3

ht=

19

.8

0 e

le

=3

0.7

5

8 a

dt+

2

sta

=9

02

.1

3

ht=

19

.8

0 e

le

=2

8.9

1

9 a

dt+

1

sta

=1

06

2.1

3

ht=

18

.9

0 e

le

=2

4.5

1

10

a

dt+

2

sta

=1

22

2.1

3

ht=

19

.8

0 e

le

=2

1.9

1

11

a

dt+

2

sta

=1

34

8.1

3

ht=

19

.8

0 e

le

=2

6.6

9

153.00

157.00

150.00 155.00

160.00

160.00

126.00

E

.T

. S

a

lto

G

ra

n

d

e

L

i

n

e

a

1

3

2

k

V

Lin

ea 1

32kV

C

a

m

in

o

LA

T 500kV

LA

T 500kV

Cañada

C

a

m

i

n

o

C

a

m

i

n

o

C

a

m

i

n

o

PI 0.00

0°00'00"

PI 87.12

64°54'48"

PI 287.13

-26°56'44"

1 2 3 4 5 6 7 8 9 10 11

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

N

o

r

t

h

N

o

r

t

h

N

orth

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 1 de 11

Page 2: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

10

20

30

40

50

PLS-CADD Drawing

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

2600

2700

10

20

30

40

50

PI 14°51'21"

11

a

dt+

2

sta

=1

34

8.1

3

ht=

19

.8

0 e

le

=2

6.6

9

12

a

dt+

1

sta

=1

50

1.1

3

ht=

18

.9

0 e

le

=3

0.9

5

13

a

dt+

1

sta

=1

64

3.1

3

ht=

18

.9

0 e

le

=3

1.1

2

14

a

dt-1

sta

=1

78

5.1

3

ht=

17

.1

0 e

le

=2

7.4

7

15

a

dt

sta

=1

92

7.1

3

ht=

18

.0

0 e

le

=2

4.3

9

16

a

dt-1

e

sta

=2

06

9.1

3

ht=

17

.1

0 e

le

=2

0.3

4

153.00

142.00 142.00

142.00

142.00

143.78

PI -47°15'28"

FFCC

17 racfdt15º

sta

=2

21

2.9

1

ht=

19

.8

0 e

le

=2

1.8

5

18

rcfd

t

sta

=2

25

2.5

0

ht=

19

.8

0 e

le

=2

2.0

0

19

a

ud

t-1

sta

=2

35

2.5

0

ht=

15

.3

0 e

le

=2

1.8

4

20

a

ud

t

sta

=2

45

2.5

0

ht=

16

.2

0 e

le

=2

0.9

5

21

a

ud

t

sta

=2

55

2.5

0

ht=

16

.2

0 e

le

=2

1.0

9

39.59

100.00

100.00100.00

88.86

22 radtm47°

sta

=2

64

1.3

6

ht=

25

.2

0 e

le

=2

0.2

5

237.42

C

a

m

in

o

C

a

m

i

n

o

C

a

m

i

n

o

Calle Publica

FFCC

FFCC

FFCC

PI 2212.91

14°51'21"

PI 2641.36

-47°15'28"

12 13 14 15 16 17 18 19 20 21 22

N

orth

N

o

r

t

h

N

o

r

t

h

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 2 de 11

ZONA A BALIZAR

Page 3: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

10

20

30

40

50

PLS-CADD Drawing

2800

2900

3000

3100

3200

3300

3400

3500

3600

3700

3800

3900

4000

4100

10

20

30

40

50

PI 36°22'51"

23

rrd

t+

8.5

sta

=2

87

8.7

8

ht=

27

.0

0 e

le

=1

6.2

8

237.42

253.10

24 radt36º

sta

=3

13

1.8

8

ht=

22

.5

0 e

le

=1

3.2

9

25

sd

t+

2

sta

=3

33

6.8

8

ht=

23

.4

e

le

=1

3.0

0

26

sd

t

sta

=3

54

1.8

8

ht=

21

.6

0 e

le

=1

3.9

6

27

sd

t

sta

=3

74

6.8

8

ht=

21

.6

0 e

le

=1

4.6

3

28

rrd

tcve

sta

=3

95

1.8

8

ht=

25

.2

0 e

le

=1

8.0

8

29

a

ud

tcv+

1

sta

=4

05

9.8

8

ht=

22

.5

0 e

le

=1

6.4

8

205.00

108.00

108.00

R

U

T

A

P

R

O

V

.

N

°

1

5

a

C

o

n

c

o

r

d

i

a

E

x

. R

u

ta

N

°1

4

a

C

o

n

c

o

rd

ia

LMT 7,6kV

PI 3131.88

36°22'51"

23 24 25 26 27 28 29 30

N

o

r

t

h

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 3 de 11

205.00 205.00

205.00

Page 4: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

10

20

30

40

50

PLS-CADD Drawing

4200

4300

4400

4500

4600

4700

4800

4900

5000

5100

5200

5300

5400

5500

10

20

30

40

50

PI -89°51'03"

30

a

ud

tcv

sta

=4

16

7.8

8

ht=

21

.6

0 e

le

=1

7.2

9

31

a

ud

tcv+

1

sta

=4

27

5.8

8

ht=

22

.5

0 e

le

=1

8.9

1

32

a

ud

tcv

sta

=4

38

5.8

8

ht=

21

.6

0 e

le

=1

9.3

9

33

a

ud

tcv

sta

=4

49

0.8

8

ht=

21

.6

0 e

le

=2

0.1

2

34

a

ud

tcv+

1

sta

=4

59

8.6

1

ht=

22

.5

0 e

le

=2

7.4

8

35

a

ud

tcv

sta

=4

69

3.6

1

ht=

21

.6

0 e

le

=2

6.2

7

36

a

ud

tcv+

1

sta

=4

79

8.6

1

ht=

22

.5

0 e

le

=2

6.9

1

37

a

ud

tcv+

2

sta

=4

89

4.6

2

ht=

23

.4

0 e

le

=2

6.2

6

38

a

ud

tcv

sta

=4

99

8.6

2

ht=

21

.6

0 e

le

=2

9.4

8

39

a

ud

tcv

sta

=5

09

8.6

2

ht=

21

.6

0 e

le

=2

8.2

7

40

a

ud

tcv+

1

sta

=5

19

8.6

2

ht=

22

.5

0 e

le

=2

6.0

8

41

a

ud

tcv

sta

=5

29

8.6

2

ht=

21

.6

0 e

le

=2

2.9

9

42

a

ud

tcv

sta

=5

40

2.6

2

ht=

21

.6

0 e

le

=2

2.5

2

43

a

ud

tcv

sta

=5

49

8.6

2

ht=

21

.6

0 e

le

=2

2.1

5

108.00 110.00

105.00

107.73 95.00

105.00

96.01

104.00 100.00

100.00

100.00

104.00

96.00

98.15

Ca

lle

P

ub

lica

Calle Publica

Calle Publica

ce

rra

da

LMT 7,6kV

LB

T

PI 5596.77

-89°51'03"

30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 4 de 11

Page 5: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

10

20

30

40

50

PLS-CADD Drawing

5600

5700

5800

5900

6000

6100

6200

6300

6400

6500

6600

6700

6800

6900

10

20

30

40

50

PI -89°51'03"

98.15

44

rra

dtcv9

0

sta

=5

59

6.7

7

ht=

23

.4

0 e

le

=2

2.5

6

45

a

ue

sta

=5

72

0.7

7

ht=

16

.2

0 e

le

=2

1.4

2

46

a

ue

+1

sta

=5

84

0.7

7

ht=

17

.1

0 e

le

=2

0.3

3

47

a

ue

+3

sta

=5

96

2.7

7

ht=

18

.9

0 e

le

=1

9.2

3

48

a

ue

+3

sta

=6

11

6.7

7

ht=

18

.9

0 e

le

=1

9.9

5

49

a

u

sta

=6

21

8.2

7

ht=

16

.2

0 e

le

=2

2.3

2

50

a

u

sta

=6

31

9.7

7

ht=

16

.2

0 e

le

=2

4.4

9

51

a

u

sta

=6

42

1.2

7

ht=

16

.2

0 e

le

=2

6.6

7

52

a

u

sta

=6

52

2.7

7

ht=

16

.2

0 e

le

=2

8.8

6

53

a

u

sta

=6

62

4.7

7

ht=

16

.2

0 e

le

=3

1.0

6

54

a

u

sta

=6

72

5.7

7

ht=

16

.2

0 e

le

=3

2.4

1

55

a

u-1

sta

=6

82

7.2

7

ht=

15

.3

0 e

le

=3

3.1

8

56

a

u

sta

=6

92

8.7

7

ht=

16

.2

0 e

le

=3

5.2

6

124.00

120.00

122.00

154.00 101.50

101.50

101.50

101.50

102.00

101.00 101.50

101.50

101.50

BD

E

BD

E

BD

E

PI 5596.77

-89°51'03"

44 45 46 47 48 49 50 51 52 53 54 55 56

N

o

rth

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 5 de 11

Page 6: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

10

20

30

40

50

PLS-CADD Drawing

7000

7100

7200

7300

7400

7500

7600

7700

7800

7900

8000

8100

8200

8300

30

40

50

60

70

PI -0°08'31"

56

a

u

sta

=6

92

8.7

7

ht=

16

.2

0 e

le

=3

5.2

6

57

a

u

sta

=7

03

0.2

7

ht=

16

.2

0 e

le

=3

8.2

8

58

a

u

sta

=7

13

1.7

7

ht=

16

.2

0 e

le

=3

9.2

2

101.50

101.50

112.52

59

rru

+3

sta

=7

24

4.2

9

ht=

20

.2

5 e

le

=3

9.8

0

60

a

u

sta

=7

34

4.2

9

ht=

16

.2

0 e

le

=3

9.8

9

61

a

u

sta

=7

44

4.2

9

ht=

16

.2

0 e

le

=3

9.9

8

62

a

u-1

sta

=7

54

4.2

9

ht=

15

.3

0 e

le

=4

0.0

8

63

a

u

sta

=7

64

4.2

9

ht=

16

.2

0 e

le

=4

0.1

7

64

a

u

sta

=7

74

4.2

9

ht=

16

.2

0 e

le

=4

0.7

0

65

a

u+

1

sta

=7

84

4.2

9

ht=

17

.1

0 e

le

=4

1.4

4

66

a

u

sta

=7

94

4.2

9

ht=

16

.2

0 e

le

=4

2.2

2

67

a

u

sta

=8

03

9.2

9

ht=

16

.2

0 e

le

=4

2.6

2

68

a

u

sta

=8

14

4.2

9

ht=

16

.2

0 e

le

=4

3.0

6

69

a

u

sta

=8

24

4.2

9

ht=

16

.2

0 e

le

=4

3.4

8

70

a

u

sta

=8

34

4.2

9

ht=

16

.2

0 e

le

=4

3.9

0

100.00

100.00 100.00

100.00

100.00

100.00 100.00

95.00

105.00

100.00

100.00B

AN

QU

IN

A

BA

NQ

UIN

A

PI 7244.29

-0°08'31"

57 58 59 60 61 62 63 64 65 66 67 68 69 70

N

o

rth

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 6 de 11

Page 7: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

30

40

50

60

70

PLS-CADD Drawing

8400

8500

8600

8700

8800

8900

9000

9100

9200

9300

9400

9500

9600

9700

9800

40

50

60

70

80

70

a

u

sta

=8

34

4.2

9

ht=

16

.2

0 e

le

=4

3.9

0

71

a

u

sta

=8

44

4.2

9

ht=

16

.2

0 e

le

=4

4.3

2

72

a

u

sta

=8

54

4.2

9

ht=

16

.2

0 e

le

=4

4.7

4

73

a

u+

2

sta

=8

64

4.2

9

ht=

18

.0

0 e

le

=4

5.1

6

74

a

u+

3

sta

=8

74

4.2

9

ht=

18

.9

0 e

le

=4

4.9

3

75

a

u

sta

=8

84

3.2

9

ht=

16

.2

0 e

le

=4

4.5

8

76

a

u

sta

=8

94

2.2

9

ht=

16

.2

0 e

le

=4

6.7

7

77

a

u

sta

=9

04

0.2

9

ht=

16

.2

0 e

le

=4

8.4

6

78

a

u-1

sta

=9

13

8.2

9

ht=

15

.3

0 e

le

=4

7.6

7

79

a

u

sta

=9

23

6.2

9

ht=

16

.2

0 e

le

=4

6.8

7

80

a

u

sta

=9

33

6.2

9

ht=

16

.2

0 e

le

=4

7.4

1

81

a

u

sta

=9

43

6.2

9

ht=

16

.2

0 e

le

=4

8.0

5

82

a

u-1

sta

=9

53

6.2

9

ht=

15

.3

0 e

le

=4

8.5

1

83

a

u

sta

=9

63

6.2

9

ht=

16

.2

0 e

le

=4

8.9

8

84

rru

sta

=9

73

6.2

9

ht=

17

.5

5 e

le

=4

9.4

4

100.00

100.00

100.00

100.00 99.00

99.00

98.00 98.00

98.00

100.00

100.00 100.00

100.00

100.00 100.00

71 72 73 74 75 76 77 78 79 80 81 82 83 84

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 7 de 11

Page 8: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

40

50

60

70

80

PLS-CADD Drawing

9800

9900

10000

10100

10200

10300

10400

10500

10600

10700

10800

10900

11000

11100

11200

30

40

50

60

70

85

a

u

sta

=9

83

6.2

9

ht=

16

.2

0 e

le

=4

9.9

1

86

a

u

sta

=9

93

6.2

9

ht=

16

.2

0 e

le

=5

0.3

7

87

a

u

sta

=1

00

36

.2

9

ht=

16

.2

0 e

le

=5

0.0

3

88

a

u-1

sta

=1

01

36

.2

9

ht=

15

.3

0 e

le

=4

9.4

3

89

a

u

sta

=1

02

36

.2

9

ht=

16

.2

0 e

le

=4

8.8

2

90

a

u-1

sta

=1

03

36

.2

9

ht=

15

.3

0 e

le

=4

8.2

2

91

a

u

sta

=1

04

36

.2

9

ht=

16

.2

0 e

le

=4

7.6

2

92

a

u+

3

sta

=1

05

36

.2

9

ht=

17

.4

0 e

le

=4

7.0

1

93

a

u+

3

sta

=1

06

36

.2

9

ht=

16

.9

0 e

le

=4

6.3

1

94

a

u+

4

sta

=1

07

36

.2

9

ht=

18

.3

0 e

le

=4

1.8

9

95

a

u+

4

sta

=1

08

35

.2

9

ht=

19

.8

0 e

le

=3

9.3

8

96

a

u+

2

sta

=1

09

35

.2

9

ht=

18

.0

0 e

le

=3

8.0

8

97

a

u+

2

sta

=1

10

34

.2

9

ht=

18

.0

0 e

le

=3

8.0

6

98

a

u-1

sta

=1

11

32

.2

9

ht=

15

.3

0 e

le

=3

4.2

4

99

a

u

sta

=1

12

31

.2

9

ht=

16

.2

0 e

le

=3

1.8

2

100.00

100.00 100.00

100.00

100.00 100.00

100.00

100.00 100.00

100.00

99.00

100.00

99.00 98.00

99.00

BA

JO

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

Pie de

talud

85 86 87 88 89 90 91 92 93 94 95 96 97 98 99

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 8 de 11

FUNDAR A NIVEL DE CALLE

Page 9: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

30

40

50

60

70

PLS-CADD Drawing

11300

11400

11500

11600

11700

11800

11900

12000

12100

12200

12300

12400

12500

12600

30

40

50

60

70

PI 23°35'19"

99

a

u

sta

=1

12

31

.2

9

ht=

16

.2

0 e

le

=3

1.8

2

10

0 a

u

sta

=1

13

30

.2

9

ht=

16

.2

0 e

le

=3

1.8

9

10

1 a

u

sta

=1

14

29

.2

9

ht=

16

.2

0 e

le

=3

1.9

8

10

2 a

u

sta

=1

15

28

.2

9

ht=

16

.2

0 e

le

=3

4.0

3

10

3 a

u

sta

=1

16

27

.2

9

ht=

16

.2

0 e

le

=3

6.0

8

10

4 a

u

sta

=1

17

26

.2

9

ht=

16

.2

0 e

le

=3

9.0

4

10

5 a

u+

4

sta

=1

18

16

.2

9

ht=

19

.8

0 e

le

=4

1.9

0

10

6 a

u-1

sta

=1

19

16

.2

9

ht=

15

.3

0 e

le

=4

0.4

7

10

7 a

u-1

sta

=1

20

07

.2

9

ht=

15

.3

0 e

le

=3

9.3

4

10

8 a

u

sta

=1

21

02

.7

9

ht=

16

.2

0 e

le

=3

8.5

3

10

9 a

u-1

sta

=1

21

98

.2

9

ht=

15

.3

0 e

le

=3

7.9

2

99.0099.00

99.00

99.00

99.00

90.00 100.00

91.00

95.50 95.50

94.71

PI -23°32'41"

110 rau24°+5

sta

=1

22

93

.0

0

ht=

22

.0

5 e

le

=3

8.8

3

49.79

111 rau24°+4

sta

=1

23

42

.7

9

ht=

21

.1

5 e

le

=4

0.1

4

11

2 a

u-1

sta

=1

24

32

.2

9

ht=

15

.3

0 e

le

=4

1.6

9

11

3 a

u

sta

=1

25

21

.7

9

ht=

16

.2

0 e

le

=4

2.7

6

11

4 a

u

sta

=1

26

11

.2

9

ht=

16

.2

0 e

le

=4

1.1

6

89.50

89.50 89.50

TE

MP

.

14°C

PI 12293.00

23°35'19"

PI 12342.79

-23°32'41"

99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114

N

o

rth

N

o

r

t

h

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 9 de 11

Page 10: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

30

40

50

60

70

PLS-CADD Drawing

12600

12700

12800

12900

13000

13100

13200

13300

13400

13500

13600

13700

13800

13900

14000

30

40

50

60

70

PI -90°00'39"

11

4 a

u

sta

=1

26

11

.2

9

ht=

16

.2

0 e

le

=4

1.1

6

11

5 a

u-1

sta

=1

27

00

.7

9

ht=

15

.3

0 e

le

=4

0.0

8

11

6 a

u+

5

sta

=1

27

90

.2

9

ht=

20

.7

0 e

le

=3

9.0

0

11

7 a

u

sta

=1

28

82

.7

9

ht=

16

.2

0 e

le

=3

9.8

4

11

8 a

u

sta

=1

29

75

.2

9

ht=

16

.2

0 e

le

=4

1.8

2

11

9 a

u

sta

=1

30

67

.7

9

ht=

16

.2

0 e

le

=4

3.8

1

12

0 a

u-1

sta

=1

31

60

.2

9

ht=

15

.3

0 e

le

=4

6.2

6

12

1 a

u

sta

=1

32

52

.7

9

ht=

16

.2

0 e

le

=5

0.2

6

12

2 a

u-1

sta

=1

33

45

.2

9

ht=

15

.3

0 e

le

=4

9.6

5

12

3 a

u+

1

sta

=1

34

43

.7

9

ht=

17

.1

0 e

le

=4

9.5

3

12

4 rrch

+1

sta

=1

35

31

.5

9

ht=

15

.3

0 e

le

=4

7.5

4

12

5 rrch

+0

.5

sta

=1

35

91

.5

9

ht=

14

.8

5 e

le

=4

5.7

3

89.50

89.50 92.50

92.50

92.50

92.50

92.50 92.50

98.50 87.80

60.00

125.20

12

6 ra

m9

0+

12

.5

sta

=1

37

16

.7

9

ht=

27

.0

0 e

le

=4

3.6

1

12

7 a

u+

1

sta

=1

38

14

.7

9

ht=

17

.1

0 e

le

=4

7.4

6

12

8 a

u

sta

=1

39

12

.7

9

ht=

16

.2

0 e

le

=4

6.3

9

12

9 a

u

sta

=1

40

10

.7

9

ht=

16

.2

0 e

le

=4

6.6

5

98.00

98.00

98.00

PI 13716.79

-90°00'39"

114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129

N

o

rth

N

o

rth

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 10 de 11

Page 11: PLS-CADD Drawing North - n 2016-0411... · PDF filePLS-CADD Drawing-0 100200 3004005006007008009001000110012001300 10 20 30 40 50 3, 3, 1 t-existsta=0.00ht=18.30 ele=27.20 87.12 3,

30

40

50

60

70

PLS-CADD Drawing

14000

14100

14200

14300

14400

14500

14600

14700

14800

14900

15000

30

40

50

60

70

PI -10°02'02"

12

9 a

u

sta

=1

40

10

.7

9

ht=

16

.2

0 e

le

=4

6.6

5

13

0 a

u

sta

=1

41

08

.7

9

ht=

16

.2

0 e

le

=4

6.5

7

13

1 a

u-1

sta

=1

42

06

.7

9

ht=

15

.3

0 e

le

=4

5.9

3

13

2 a

u

sta

=1

43

04

.7

9

ht=

16

.2

0 e

le

=4

6.3

9

13

3 a

u-1

sta

=1

44

03

.7

9

ht=

15

.3

0 e

le

=4

6.1

5

13

4 a

u

sta

=1

45

02

.7

9

ht=

16

.2

0 e

le

=4

7.4

3

13

5 a

u

sta

=1

46

01

.7

9

ht=

16

.2

0 e

le

=4

7.1

1

13

6 a

u

sta

=1

47

02

.7

9

ht=

16

.2

0 e

le

=4

6.8

7

13

7 a

u+

1

sta

=1

47

94

.7

9

ht=

17

.1

0 e

le

=4

1.7

4

13

8 a

u+

1

sta

=1

48

92

.7

9

ht=

17

.1

0 e

le

=3

9.5

1

98.00

98.00

98.00 99.00

99.00

99.00

101.00

92.00

98.00

100.88

PI 0°00'00"

Term

inal frente a P

ortico

13

9 ra

u1

2+

2

sta

=1

49

93

.6

7

ht=

19

.3

5 e

le

=3

7.9

7

14

0 t

sta

=1

50

79

.6

5

ht=

18

.0

0 e

le

=3

7.9

7

85.98

Calle Los Tilos

Gu

ale

gu

ay

Ca

lle

T

ala

Ca

lle

Dia

ma

nte

Calle Los Tilos

Linea 33kV

E

.T

. C

o

n

c

o

rd

ia

PI 14993.67

-10°02'02"

PI 15078.97

0°00'00"

129 130 131 132 133 134 135 136 137 138 139 140

N

o

rth

North

Plano N°: L002

Planialtimetría

Salto Grande - Concordia II

LAT: Salto Grande-Concordia II

Conductor: ACSR 300/50 mm2

Hilo de Guardia: OPGW 24 fibras

Vert. Scale

Horiz. Scale

2.5 m

20.0 m

LAT 132 kV

EJE DE PROYECTO LAT 132 kV

SOPORTE DE SUSPENSION

LBT

LMT 33 kV

VERTICE

FFCC

ALAMBRADOS

ARROYOS

CAMINOS

LMT 13,2 kV

LEAT 500 kV

ARBOLES

GASODUCTO

LAT 132 kV existente

TELÉFONO

LMT 7,6 kV

REFERENCIAS

Hoja 11 de 11