pma – wir schützen ihre kabel. -...
TRANSCRIPT
PMA Main CataloguePMA Hauptkatalog
PMAFIX Pro • PMAFIX / PMAFLEX
PMA Smart Line • PMAJACKThe content of the Thomas & Betts catalogue has been carefully checked for accuracy at the time of print. However, Thomas & Betts doesn‘t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may result from any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain.
Copyright Thomas & Betts 2008. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part of this publica-tion may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Images, trade marks, brands, designs and technology are also protected by other intellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change and improve any product specifications or other mentions in the catalogue at its own discretion and at any time. These conditions of use are governed by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute.
Diese Thomas& Betts Broschüre wird ohne Gewähr im Hinblick auf die Korrektheit der darin enthaltenen Informationen, Produkt-und Leistungs-beschreibungen herausgegeben. Der Inhalt der Broschüre wurde sorgfältig überprüft. Gleichwohl haftet Thomas& Betts nicht für Verluste oder Schäden, die sich infolge von Unrichtigkeiten oder Lücken der darin enthaltenen Infor-mationen ergeben.
© Copyright 2008 Thomas& Betts. Das Urheberrecht an dieser Broschüre steht Thomas& Betts zu, soweit nicht anders angegeben. Ohne unsere vorherige schriftliche Zustimmung darf kein Teil der Broschüre in irgendeiner Form oder durch irgendwelche Mittel reproduziert, kopiert oder verbreitet werden. Abbil-dungen, Warenzeichen, Marken, Designs, und Technologie werden auch durch weitere Gesetze zum Schutz des Urheberrechts geschützt; sie dürfen ohne schriftliche Einwilligung ihrer jeweiligen Eigentümer in keiner Weise vervielfäl-tigt werden. Thomas& Betts behält sich das Recht vor, Produktspezifikationen und sonstige Angaben in dieser Broschüre jederzeit nach eigenem Ermessen zu ändern und zu verbessern. Diese Benutzungsbedingungen unterliegen dem Recht der Niederlande. Im Fall von Rechtsstreitigkeiten sind ausschließlich die Gerichte von Amsterdam zuständig.
PMA
-KA
T. 1
D/E
– V
1.1
– 01
/13
PMA has been developing, producing and selling top quality cable protection systems since 1975. Our high quality Swiss products have rapidly earned us an excellent reputation world-wide and established us as the market leader. Our range of more than 6,500 products gives customers the protection they need in railway, mechanical engineering and shipbuilding applications worldwide. PMA products are also the solution of choice in automation, building installations and other projects where power and data cables require dependable protection.
Seit 1975 entwickelt, produziert und vertreibt die PMA Kabelschutzsysteme von höchster Qualität. Mit unseren Schweizer Qualitätsprodukten haben wir uns innerhalb kurzer Zeit weltweit einen exzellenten Namen geschaffen und uns als Marktführer etabliert. Das heute über 6’500 Produkte umfassende Sortiment bewährt sich weltweit im Bahn-, Maschinen- und Schiffbau. Aber auch in der Automation, bei Gebäudeinstallationen und in vielen weiteren Bereichen, wo Energie und Datenleitungen zuverlässig geschützt sein müssen, werden bevorzugt PMA-Produkte eingesetzt.
Germany / DeutschlandPMA Deutschland GmbHRobert-Bosch-Strasse 7D-97437 Hassfurt Tel: +49 / 9521 957 71-0Fax: +49 / 9521 957 [email protected] · www.pma-de.com
Great Britain / GrossbritannienPMA UK LimitedUnit 4 Imperial Court, Magellan CloseWalworth Industrial Estate UK-Andover, Hants SP10 5NTTel: +44 / 1264 333527Fax: +44 / 1264 [email protected] · www.pma-uk.com
USA Thomas & Betts Corporation8155 T&B BoulevardUS-Memphis, TN 38125Tel: +1 / 901 252 8000Fax: +1 / 901 252 1354www.tnb.com
PMA Headquarters / PMA Hauptsitz
Switzerland / SchweizPMA AG (Headquarters)Aathalstrasse 90 · CH-8610 UsterTel: +41 / 44 905 61 11 · Fax: +41 / 44 905 61 [email protected] · www.pma.ch
PMA – We protect your cables. PMA – Wir schützen Ihre Kabel.
PMA Subsidiaries / PMA Tochterfirmen
Austria / ÖsterreichPMA GmbHPernerstorferstrasse 9A-2700 Wiener NeustadtTel: +43 / 2622 204 66 / 0Fax: +43 / 2622 203 [email protected] · www.pma-at.com
France / FrankreichPMA France S.A.R.L.18, Avenue du Québec, Néflier Villebon Silic 607F-91945 Courtabœuf CedexTel: +33 / 169 59 16 66Fax: +33 / 169 59 16 [email protected] · www.pma-fr.com
Italy / ItalienPMA Italia s.r.l.Via Marmolada 12I-20037 Paderno Dugnano (MI)Tel: +39 / 02 91084241Fax: +39 / 02 [email protected] · www.pma-it.com
Spain / SpanienThomas & Betts Spain S.L.Pol. Ind. Cardedeu SudAvda. Vallés, 22E-08440 Cardedeu (Barcelona)Tel: +34 / 938 45 45 70Fax: +34 / 938 45 47 80 [email protected] · www.pma-es.com
Contents / Inhaltsverzeichnis
Contents Inhaltsverzeichnis
About PMA
5 Company Profile 6 Who we are 8 Application Areas
Conduits
10 Conduit Guide 14 Conduits 15 PMAFLEX Pro 19 PMAFLEX 30 PMAFLEX Multilayer 34 PMA FLEXPLus 36 PMA Divisible System 38 PMA Smart Line
Connectors
PMAFIX Pro 40 Overview 42 Safety Sealing Systems Part Number Code 43 Size Codes / Installation 44 – Metric / Metal 48 – Female Thread Adapters 49 – Sealing element
PMAFLEX
PMAFIX Pro
Über PMA
5 Firmenvorstellung 6 Wer wir sind 8 Anwendungsgebiete
Wellrohre
10 Rohrübersicht 14 Wellrohre 15 PMAFLEX Pro 19 PMAFLEX 30 PMAFLEX Mehrschicht 34 PMA FLEXPLus 36 PMA Teilbares System 38 PMA Smart Line
Anschlüsse
PMAFIX Pro 40 Übersicht 42 Sicherheits- und Dichtsysteme Nummernschlüssel 43 Grössen-Codierungen / Montage 44 – Metrisch / Metall 48 – Innengewindeadapter 49 – Dichtelement
Important Information Wichtige Information
The specifications and instructions for our customers in this document reflect the product engineering level at the time of manufacturing. PMA AG accepts no liability for damages resulting from unprofessional installation or application or misuse for a purpose. This dis claimer also includes damages to third parties. It is the cus tomer‘s responsibility to check the delivered products and immediately notify PMA AG of detected faults. It is also the customer‘s res ponsibility to test the delivered product on its applicability for the intended purpose. PMA AG will accept no liability or responsibility for their products if a product or a PMA system is combined or used together with third-party products, i.e. products from other companies than PMA AG. Jurisdiction in all legal disputes concer-ning product liability have the courts of the canton of Zurich/Switzerland. Swiss law applies.
To guarantee punctual deliveries please check availability of products before orde-ring.
The text, pictures, drawings and applica-tion photos which are published in this document may not, in part, or totally, be copied or used by any third party in any form or way. Especially the downloading of text, pictures, drawings, and applica-tion photos onto Online Services is strictly forbidden, irrespective of if they are edited for this purpose or not. At all times PMA AG reserves the right to take all legal steps necessary.
For more information go to: www.pma.ch
Die in diesem Dokument für unsere Kunden enthaltenen Angaben und Instruktionen entsprechen dem neu-esten Stand unserer Technik zum Zeit-punkt der Herstellung des Produktes. Die PMA AG lehnt jede Haftung bei unsach-gemässer Montage oder Verwendung sowie Zweckentfremdung des Produktes ab. Dieser Haftungsausschluss umfasst auch allfällige Drittschäden. Es obliegt dem Kunden, die gelieferte Ware zu prüfen und allfällig festgestellte Mängel sofort der PMA AG anzuzeigen. Es obliegt ferner dem Kunden, die Ware auf ihre Eignung zwecks einer spezifischen Anwendung zu überprüfen. Die PMA AG lehnt jegliche Haftung für ihre Produkte ab, wenn ein einzelnes Produkt oder ein PMA-System mit Fremdprodukten, d.h. Produk-ten anderer Unternehmungen kombiniert bzw. verwendet wird.Gerichtsstand für Streitig keiten bezüg-lich Produkthaftung sind die Gerichte des Kantons Zürich/Schweiz. Es kommt Schweizer Recht zur Anwendung.
Um einen reibungslosen Bestellungs-ablauf zu garantieren, bitten wir Sie, die Produkteverfügbarkeit vorab zu klären.
Die in diesem Dokument publizierten Texte, Bilder, Skizzen und Anwen dungs-fotos dürfen von Dritten weder ganz noch teil weise kopiert, bearbeitet oder ander weitig ver wendet werden. Ausge schlossen ist insbesondere auch eine Einspeisung auf Online-Dienste, unab hängig da von, ob die Fotos, Skizzen oder Texte zu diesem Zweck bearbeitet werden oder nicht. PMA AG behält sich jederzeit rechtliche Schritte vor.
Ergänzende Informationen unter: www.pma.ch
3
Contents / Inhaltsverzeichnis
Divisible System
92 Connectors 93 Conduits
Large Sizes
87 Connectors 90 Conduits 91 Accessories
PMA Divisible System
PMAGRIP JUMBO
Teilbares System
92 Anschlüsse 93 Wellrohre
Extra Gross
87 Anschlüsse 90 Wellrohre 91 Zubehör
Connectors
PMAFIX 50 Part Number Codes 51 Size Codes 52 Safety Sealing Systems 53 Installation 54 – Metric / Polyamide 57 – Metric / Metal 64 – PG / Polyamide 68 – PG / Metal 72 – GAS / Polyamide 74 – NPT / Polyamide 75 – Flange 76 – Female Thread Adapters 80 – Y, V, T Pieces 82 – Conduit Supports
PMAFIX Anschlüsse
PMAFIX 50 Nummernschlüssel 51 Grössen-Codierungen 52 Sicherheits- und Dichtsysteme 53 Montage 54 – Metrisch / Polyamid 57 – Metrisch / Metall 64 – PG / Polyamid 68 – PG / Metall 72 – GAS / Polyamid 74 – NPT / Polyamid 75 – Flansch 76 – Innengewindeadapter 80 – Y-, V-, T-Verteiler 82 – Halter
Special Products
94 Swivel Connectors 95 Positioning Elbow Adapters 96 Swivel Adapters 97 Spin Couplers 98 Connections 99 Conduit Adapters100 Terminal and Protection Sleeves
Spezialprodukte
94 Drehbare Armaturen 95 Positionierbare Winkeladapter 96 Drehbare Adapter 97 Positionsadapter 98 Verbindungen 99 Rohradapter100 Endtüllen und Schutzmuffen
4
Plastic Braided Hoses
PMAJACK 118 Braided Hoses120 Hot Cutting Tool121 Termination121 Polyamide Female Thread Adapters121 Metal Female Thread Adapters
Technical Annex
122 Testing Methods126 Ingress Protection 128 Thread Dimensions130 Torques131 Application Guidelines132 Chemical Resistance133 Index
PMAJACK Kunststoff-Geflechte
PMAJACK118 Geflechtschläuche120 Heiss-Schneidegerät 121 Endabschluss121 Polyamid Innengewindeadapter121 Metall Innengewindeadapter
Technischer Anhang
122 Prüfmethoden126 Eindringschutz128 Gewinde-Codierungen130 Drehmomente131 Anwendungstechnische Hinweise132 Chemische Beständigkeit133 Index
Accessories 101 Clips102 Lock Nuts104 Enlargers / Reducers107 Sealing Caps108 Flat Gaskets110 Plug Screws111 Tools
Zubehör
101 Sperren102 Gegenmuttern104 Erweiterungen / Reduktionen107 Rohrdichtungen108 Gewindeflachdichtungen110 Verschluss-Schrauben111 Werkzeuge
Contents / Inhaltsverzeichnis
Connectors
PMA Smart Line112 Part Number Codes113 Overview and Size Codes114 Safety Sealing Systems Installation115 – Metric / Polyamid 116 – PG / Polyamid
PMA Smart Line Anschlüsse
PMA Smart Line112 Nummernschlüssel113 Übersicht und Grössen-Codierungen114 Sicherheits- und Dichtsysteme Montage115 – Metrisch / Polyamid116 – PG / Polyamid
5
Company Profile
A Swiss Company with a Global Presence
PMA headquarters is located in Uster (Switzerland), close to Zurich. The majority of what we produce for the world market is made at this location. Also our research and development department is located here.
PMA has fully owned subsidiaries in all of the major European industrial countries Germany, the UK, France, Spain, Austria, and Italy.
Thanks of our large network of professional partners in all of the major industrialised countries around the globe, we are able to quarantee best quality regarding products, technical support, service and fast delivery.
PMA products are already sold in more than 45 countries and we continousely expand our partner base.
PMA belongs to the Thomas & Betts Corporation.
Firmenvorstellung
Schweizer Unternehmen mit globaler Präsenz
Der PMA-Hauptsitz befindet sich in der Schweiz, in Uster, im Grossraum Zürich. Ein Grossteil der Produktion für den Welt-markt wird vor Ort hergestellt. Auch die intensive Forschung und Entwicklung findet hier statt.
Wir sind mit Tochterfirmen in Deutschland, England, Frankreich, Spanien, Österreich und in Italien vertreten.
Mit vielen Partnerfirmen in allen wichtigen Industrieländern rund um den Globus garantieren wir Tausenden von Kunden jederzeit beste Qualität in Bezug auf Produkte, Service und technische Bera-tung sowie kurze Lieferzeiten.
PMA-Produkte werden heute bereits in über 45 Ländern vertrieben und wir erweitern ständig unser Partnernetz.
PMA ist ein Unternehmen der Thomas & Betts Corporation.
C
D A
F I
E G
About PMA / Über PMA
Who we are / Wer wir sind
6
About PMA / Über PMA
Who we are / Wer wir sind
From Pioneer to Market Leader
PMA AG has been developing, producing, and selling top-quality cable protection systems since 1975. Our high-quality Swiss products have rapidly earned us an excellent reputation worldwide and established us as the mar-ket leader. Our range of more than 6,500 products gives customers the protection they need in railway, mechanical enginee-ring, and shipbuilding applications world-wide. PMA products are also the solution of choice in automation, building instal-lations and other projects where power and data cables require dependable pro-tection.
Setting New Standards and Trends
Customer needs are a top priority at PMA AG, and we work every day to ensure all our customer requirements are met in our products. We offer cable protection solu-tions and services that are tailored to meet requirements in every type of application. Our range extends from basic items right up to the most demanding high-tech products. We can develop system solutions and special products that are designed to meet specific customer re-quirements. Our intensive research and development activities, which include the field of new materials, are a major reason why PMA AG continues to set new stan-dards and trends in the cable protection marketplace. These efforts together with excellent quality and service have helped us build up an outstanding reputation with leading corporations around the world.
Vom Pionier zum Marktführer
Seit 1975 entwickelt, produziert und vertreibt die PMA AG Kabelschutzsysteme von höchster Qualität. Mit unseren Schweizer Qualitätsprodukten haben wir uns innerhalb kurzer Zeit welt-weit einen exzellenten Namen geschaf-fen und uns als Marktführer etabliert. Das heute über 6’500 Produkte umfassende Sortiment bewährt sich weltweit im Bahn-, Maschinen- und Schiffbau. Aber auch in der Automation, bei Gebäudeinstallationen und in vielen weiteren Bereichen, wo Energie und Datenleitungen zuverlässig geschützt sein müssen, werden bevorzugt PMA-Produkte eingesetzt.
PMA setzt neue Massstäbe und Trends
Kundenorientierung wird bei der PMA AG gross geschrieben und tagtäglich umge-setzt. Wir bieten für jeden Anwendungs-bereich bedürfnisorientierte Kabelschutz-lösungen und Dienstleistungen und dies vom Basis- bis zum anspruchsvollsten High-Tech-Produkt. Dazu gehört auch die Entwicklung von Systemlösungen und speziell auf Kundenwunsch entwickelte Sonderanfertigungen. Unsere intensive Forschungs- und Entwicklungsarbeit – auchim Bereich neuer Werkstoffe – trägt dazu bei, dass die PMA AG in der Kabel- schutztechnik im Markt immer wieder neue Massstäbe setzt und Trends einlei-ten kann. Unsere Arbeit sowie die hoch stehende Qualität von Produkten und Service tragen dazu bei, dass wir bei renommierten Unternehmen auf allen Kontinenten einen ausgezeichneten Ruf geniessen.
Who we are Wer wir sind
7
About PMA / Über PMA
Who we are / Wer wir sind
Unique Benefits of PMA Products
Service to the customer is what motiva-tes us. In addition to series production, PMA AG can build fittings and conduits to meet individual requirements as a special service to our customers.
•Asafe,reliablesystem that is easy to install
•Vibration-proofconnections
•Systemconnectionstrength
•Ingressprotectionconformingto recognized test methods
•Highimpactstrength even at low temperatures
•Highcompressionstrength(peakload)
•Long-termreversed-bendingresistance
•Goodchemicalresistance
•Fireprotection(flammabilityand smoke generation)
•Goodweatherresistance
•Longwearing
…and much more
Einzigartige Produktvorteile
Unsere Motivation ist der Dienst am Kunden. Zusätzlich zur Serienfertigung bietet die PMA AG als besonderen Ser-vice die Sonderanfertigung von An-schlüssen und Schutzrohren nach indivi-duellen Wünschen an.
•Montagefreundlichkeit und Sicherheit des Systems
•VibrationssichereVerbindungen
•Systemverbindungsfestigkeit
•Systemdichtheitnachanerkannten Prüfmethoden
•Schlagfestigkeitauch bei tiefen Temperaturen
• Trittfestigkeit(Scheitellast)
•BiegefestigkeitfürdenDauereinsatz
•ChemischeBeständigkeit
•Brandschutzeigenschaften hinsichtlich Brandverhalten und Rauchgasent wicklung
•Witterungsstabilität
• Langzeiteigenschaften
...u.v.m.
8
Areas of Applications
Mechanical Engineering
A considerable number of PMA cable protection systems are used in mecha-nical engineering. A few examples illust-rate how varied the range of mechanical engineering applications is. You will find our products in machine tools, packaging machines, printing machines, as well as heating, ventilation, conveyer, and filling systems. PMA products also make a vital contribution to the smooth operation of high voltage and emergency power systems, can production machinery and woodworking machines, etc. PMA cable protection solutions safeguard cables, wires and data links against heat, cold, tensile stress, pressure stress, and other external influences in the important mechanical engineering industry.
Railway / Railway-Infrastructure
PMA products have proven their depen-dability in railway construction projects around the world. This is the reason why large corporations including Siemens, Alstom, Bombardier, Deutsche Bahn, and SNCF have chosen us as supplier over a period of many years. Our special railway engineering product line provides protec-tion and safety on signalling systems, cou-plings, trucks, and gangways, as well as roof,andunderfloorequipment.The range of applications is very extensive. PMA products contribute to the safe operation of trams, locomotives, freight cars, high-speed trains, and even roller coasters.
Anwendungsgebiete
Maschinenbau
Ein beachtlicher Teil der PMA-Kabelschutz-systeme wird im Maschinenbau einge-setzt. Wie vielfältig das Anwendungsgebiet im Maschinenbau ist, veranschaulichen einige Beispiele: Werkzeug-, Verpackungs- und Druckmaschinen werden ebenso mit unseren Produkten ausgestattet wie Heizungs-, Lüftungs-, Förder- und Abfüllan-lagen. Auch in Hochspannungs- und Not-stromanlagen oder in Dosenfertigungs- und Holzbearbeitungsmaschinen u.v.m. sind unsere Produkte wichtige Bestandteile für einen reibungslosen Betrieb. PMA-Kabelschutzlösugen schützen in dem bedeutenden Industriezweig Maschinenbau Kabel, Leitungen und Datenverbindungen zuverlässig vor äusseren Einflüssen wie Hitze, Kälte, Zug- und Drucklast.
Bahn / Bahninfrastruktur
PMA-Produkte bewähren sich im Bahn-bau auf der ganzen Welt. Deshalb dürfen wir Grossunternehmen aus dieser Bran-che, beispielsweise Siemens, Alstom, Bombardier, die Deutsche Bahn und SNCF, seit Jahren zu unseren Kunden zählen. Unser eigens für den Bahnbau entwickeltes Kabelschutzprogramm bietet Schutz und Sicherheit bei Signalanlagen, Kupplungen, Drehgestellen, Wagenüber-gängen, Dach- und Unterflurinstallationen. Die Einsatzbereiche sind sehr vielfältig. Strassenbahnen, Lokomotiven, Frachtwag-gons, Hochgeschwindigkeitszüge und sogar Achterbahnen sind sicher unter-wegs mit PMA-Produkten.
About PMA / Über PMA
Areas of Applications / Anwendungsgebiete
9
Automation
In the field of automation, there is a need for products that can withstand the stress of motion-intensive applications. Solutions developed by PMA AG for the automation industry fully meet these requirements. Special conduit designs, supports and abrasion protection sleeves provide optimal protection along the entire length of all moving elements, enabling engi-neers to achieve a massive reduction in torsional forces. There is good reason why leading robotics manufacturers rely on PMA technology.
Countless Applications
PMA cable protection products can be used in an extremely wide range of applications. The list is virtually endless and includes industries such as telecom-munications, construction equipment and medical equipment. Wherever there is a need for cable protection, the PMA AG product portfolio provides safe, depen-dable, forward-looking solutions or will develop them specially for you to meet your individual needs.
Automation
In der Automation sind Kabelschutz- Produkte gefragt, die extrem beweglichen Anwendungen jederzeit Stand halten. Die von der PMA AG entwickelten Lösungen für den Automationsbereich tragen diesen hohen Anforderungen in jeder Hinsicht Rechnung: Spezielle Rohrtypen, Halte-rungen und Scheuerschutzmuffen sorgen für einen optimalen Schutz entlang aller beweglichen Elemente und ermöglichen eine massive Reduktion der Torsionskräfte. Aus diesem Grund setzen führende Robo-terbauer auf die PMA-Technologie.
Anwendungsgebiete ohne Ende
Die möglichen Anwendungsbereiche für PMA-Kabelschutzprodukte sind äusserst vielfältig und praktisch grenzenlos. Ob beispielsweise in der Telekommunikation, im Baugewerbe oder der Medizinaltechnik, wo immer Kabelschutz gefragt ist, bietet die PMA AG Ihnen sichere und zukunfts- orientierte Lösungen oder entwickelt diese speziell für Sie und Ihre individuellen Bedürfnisse.
About PMA / Über PMA
Areas of Applications / Anwendungsgebiete
10
Conduits / Wellrohre
Conduit Guide / Wellrohrübersicht
General ApplicationsAllgemeine Anwendungen
PMAFLEX Pro
staticdynamic
staticdynamic
staticdynamic
staticdynamic
staticdynamic
staticdynamic
static
static
static
static
static
15 16 17 18
dynamic
dynamic
dynamic
static
static
static
static
static
indooroutdoor
indooroutdoor
staticdynamic
staticdynamic
statischdynamisch
statischdynamisch
statischdynamisch
statischdynamisch
statischdynamisch
statischdynamisch
statisch
statisch
statisch
statisch
statisch
dynamisch
dynamisch
dynamisch
statisch
statisch
statisch
statisch
statisch
InnenanwendungAussenanwendung
InnenanwendungAussenanwendung
statischdynamisch
statischdynamisch
Outdoor ApplicationsAussenanwendungen
Outdoor ApplicationsAussenanwendungen
Systems with E xtreme MovementsStark bewegte Systeme
Indoor ApplicationsInnenanwendungen
Indoor ApplicationsInnenanwendungen
TelecommunicationsTelekommunikation
Ex Hazardous Areas (ATEX)Ex-Bereich (ATEX)
Outdoor Applications with Sunlight ExposureAussenanwendungen mit Sonnenlicht
Heavy LoadsHohe Belastungen
Outdoor Applications with Sunlight ExposureAussenanwendungen mit Sonnenlicht
Moving SystemsBewegte Systeme
Outdoor General ApplicationsAllgemeine Aussenanwendungen
Outdoor Applications with Sunlight ExposureAussenanwendungen mit Sonnenlicht
Vehicle BuildingFahrzeugbau
Antistatic RequirementsAntistatische Anforderungen
Indoor Applications Innenanwendungen
Moving Systems with Antistatic RequirementsBewegte Systeme mit antistatischen Anforderungen
Passenger AreaFahrgastraum
Exposed to RadiationStrahlung ausgesetzt
Building ConstructionGebäudekonstruktionen
High Temperature ApplicationsHochtemperatur-Anwendungen
To find on page:Zu finden auf Seite:
Indoor and Tunnel ApplicationsInnen- und Tunnelanwendungen
Ap
plic
atio
n A
reas
A
nw
end
un
gsb
erei
che
Mac
hine
Bui
ldin
gM
asch
inen
bau
Trac
tion
Bahn
Rail
Infr
astr.
Bahn
-Infr
astr.
Aut
omat
ion
Auto
-m
atio
n
Ship
+ O
ff-S
hore
Schi
ffbau
+
Off-
Shor
e
Ener
gyEn
ergi
eOt
hers
W
eite
re
PHT
PLU
POH
PSXKey / Legende: recommended / empfohlen
suitable (application details to be considered) / verwendbar (anwendungstechnische Hinweise sind zu beachten)
11
Conduits / Wellrohre
Conduit Guide / Wellrohrübersicht
PMAFLEXMultilayer
DivisibleSystemPMAFLEX
19 2119 2220 2320 24 24 25 26 3028 32 36 3827 3129 33 37 38 39
CYL
ESD
PC
LPC
SPC
SLPE
LPI
S/PI
HPO
SPU
EPV
DVA
MVA
ML
VCS
VOH
XPCL
XSOL
XSOL
LXV
CS1H
PACO
FPP
COF
PMA FLEXPLus(UL-Listed)
3434 35
CUS
PUS
VUS
PMASmart Line
LLPA
LLPF
LLPO
12
Conduits / Wellrohre
Conduit Guide / Wellrohrübersicht
PMAFLEX Pro
Ductility Biegbarkeit
Reverse Bending Resistance Dauer- / Biegewechselfestigkeit
Compression Resistance Druck- / Trittfestigkeit
Low Temperature Performance Tieftemperatur-Eigenschaften
High Temperature Performance Hochtemperatur-Eigenschaften
Resistance to Weathering Witterungsbeständigkeit
DNV (Type approved)
Lloyd’s Register (Type approved)
Bureau Veritas (Type approved)
Continuous operating temperature / Temperatur bei Dauerbetrieb (Acc. to / gemäss DO 9.21-4510)
Short term max. operating temperature 168h / kurzzeitige Maximal-Temperatur bei Dauerbetrieb 168 Std. (Acc. to / gemäss DO 9.21-4360)
Nominal width min. Nennweite min.
Nominal width max. Nennweite max.
Metric size min. Metrische Grösse min.
Metric size max. Metrische Grösse max.
EN45545
NF F 16-101 + 102
BS6853
DIN 5510-2
UNI CEI 11170-3 Ed. 2005
NFPA130 (ASTM E162 - ASTM E662 - ASTM E1354) BSS7239 / SMP 800-C
Free from halogens and cadmium Halogen- und cadmiumfrei
Non flame propagating EN61386 Nicht brandausbreitend
UL Recognition File
Bi-National Recognition File UL1696 & CSA C22.2 No. 227.3-05
Bi-National Listing File UL1660 & CSA C22.2 No. 227.2.1
Mat
eria
l Pro
per
ties
Mat
eria
l-Ei
gen
sch
afte
nA
pp
rova
lsZ
ula
ssu
nge
nTe
mp
.R
ange
Tem
p.
Ber
eich
Siz
es
Grö
ssen
- b
erei
ch
PHT
PLU
POH
PSX
07
48
10
50
-50
135
180
✓ ✓
✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-25
95
-25
95
120
-100
170
200
10
48
12
50
10
48
12
50
10
48
12
50
Key / Legende: ✓ correct / trifft zu
Min. ( – )
Max. ( + )
( + )
13
Conduits / Wellrohre
Conduit Guide / Wellrohrübersicht
PMAFLEXMultilayer
PMA FLEXPLus(UL-Listed)
PMASmart Line
DivisibleSystemPMAFLEX
CYL
ESD
PC
LPC
SPC
SLPE
LPI
S/PI
HPO
SPU
EPV
DVA
MVA
ML
VCS
VOH
XPCL
XSOL
XSOL
LXV
CS1H
CUS
PUS
VUS
LLPA
LLPF
LLPO
PACO
FPP
COF
07
48
10
50
07
48
10
50
07
48
10
50
07
48
10
50
07
70
10
80
07
70
10
80
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓
✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-50
95
150
-50
105
160
-25
95
130
-50
95
150
-40
105
160
-50
105
160
-40
105
160
-40
105
160
-40
105
160
-40
105
160
-20
105
150
-40
105
160
-60
50
-50
95
150
-40
105
160
-50
95
150
-50
95
150
-40
90
150
-60
150
-50
60
-50
105
160
-40
95
150
-50
105
160
-20
90
130
-40
105
160
-50
90
120
10
48
12
50
07
125
10
146
07
125
10
146
07
125
10
146
07
125
10
146
07
125
10
146
12
48
16
50
12
48
16
50
12
48
16
50
12
48
16
50
07
125
10
146
07
95
10
106
07
95
10
106
07
95
10
106
17
70
20
80
17
48
20
50
17
48
20
50
17
48
20
50
10
29
12
32
07
95
10
106
The product groups
•PMAFLEXPro •PMAFLEX •PMAFLEXPLus •PMAFLEXMultilayer •PMADivisibleSystem •PMASmartLine
offer many different conduit types for divers applications with variousetechnicalrequirementstoprotecthumansandcables.
Conduitsizesrangefrom6mmto125mmdiameters,fromlight-weighttoheavyweight,andfrompliabletohighlyflexible.PMAalsooffersslitanddivisibleconduits.Standardcoloursareblackand grey. Many conduits are specially approved, e.g. CSA, UL Recognition,NF,SNCF,DB,etc.
Die Produktegruppen
• PMAFLEX Pro • PMAFLEX • PMA FLEXPLus • PMAFLEX Multilayer • PMA Teilbares System • PMA Smart Line bieten viele verschiedene Rohrtypen für diverse Anwendungen mit unterschiedlichsten tech nischen Ansprüchen bezüglich Personen- und Kabelschutz.
Die Rohrgrössen reichen von 6 mm bis 125 mm Durchmesser, in Ausführungen von leicht bis schwer, und von biegbar über flexibel bis hochflexibel. Das Sortiment führt aber auch geschlitzte und teilbare Rohre. Standard farben sind schwarz und grau. Für viele Rohrtypen bestehen spezielle Zulassungen, z.B. CSA, UL Recognition, NF, SNCF, DB, um nur einige zu nennen.
Conduits Wellrohre
14
Profile / Profil: T = Fine Profile / Feinprofil D = Fine Profile / Feinprofil G = Coarse Profile / Grobprofil
Colour / Farbe: B = black / schwarz S = grey / grau
Type / Typ
Colour Inner Layer (for Multilayer conduit) Farbe Innenschicht (bei Mehrschicht-Wellrohr): G = green / grün B = blue / blau
Nominal Width / Nennweite
Multilayer conduit / Mehrschicht-Wellrohr
Conduits – Part Number Code Wellrohre – Nummernschlüssel
X S GT – 12PCL
Conduits / Wellrohre
Conduits–PartNumberCode/Wellrohre – Nummernschlüssel
15For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
PHT highly flexible, medium/heavy hochflexibel, mittelschwer/schwer• For applications at high and very low temperatures• For dynamic applications
• Für Anwendungen bei hohen und sehr tiefen Temperaturen• Für dynamische Anwendungen
PHTT-07B 07 10 6.2 10.0 15 / 40 50PHTT-10B 10 12 9.6 13.0 20 / 55 50PHTT-12B 12 16 12.0 15.8 30 / 65 50PHTT-17B 17 20 16.2 21.2 40 / 70 50PHTT-23B 23 25 22.6 28.5 45 / 95 50PHTG-17B 17 20 15.2 21.2 40 / 75 50PHTG-23B 23 25 22.0 28.5 45 / 100 50PHTG-29B 29 32 27.7 34.5 55 / 120 50PHTG-36B 36 40 35.8 42.5 60 / 180 30PHTG-48B 48 50 46.8 54.5 70 / 200 30
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**/dyn.***Radius
VEMeter
• High-grade, specially formulated polyamide elastomer• High resistance to ultra violet rays and weathering• Both excellent flexibility and high compress strength• Extremely good impact resistance at very low temperatures• Enhanced temperature range compared to standard polyamides• Free from halogens and cadmium• Temperature range: –50 °C to +135 °C; Short-term: +180 °C
• Hochwertiges, speziell formuliertes Polyamid-Elastomer• Hohe UV- und Witterungsbeständigkeit• Hervorragende Flexibilität bei hoher Scheitellast• Extrem gute Schlagzähigkeit bei sehr tiefen Temperaturen• Erhöhter Temperaturbereich gegenüber Standard-Polyamiden• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +135 °C; kurzzeitig: +180 °C
Conduits / Wellrohre
PMAFLEX Pro
min.PHT-Index
max.
ductility
fatigue reversed bending
compression resistance
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit (PHTT-17B)
Druck- / Trittfestigkeit (PHTG-17B)
Kälteeigenschaften
Witterungseigenschaften
** stat. R = lowest recommended bending radius for static (fixed) installation
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung
*** dyn. R = lowest recommended bending radius for dynamic (flexible) installation
*** dyn. R = kleinster empfohlener Biegeradius für dynamische (flexible) Verlegung
Fine profile T Feinprofil T
Tight bending radius Enge Biegeradien
Coarse profile G Grobprofil G
High pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
16 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Pro
PLU flexible, medium, semi-rigid for static applications flexibel, mittelschwer, gute Steifigkeit für statische Anwendungen• For applications with highest fire safety performance requirements (e.g. London Underground)
• Für höchste Brandschutzanforderungen (z.B. London Underground)
PLUT-10B PLUT-10S 10 12 9.5 13.0 20 50PLUT-12B PLUT-12S 12 16 11.8 15.8 30 50PLUG-17B PLUG-17S 17 20 15.3 21.2 40 50PLUG-23B PLUG-23S 23 25 22.2 28.5 45 50PLUG-29B PLUG-29S 29 32 28.7 34.5 55 50PLUG-36B PLUG-36S 36 40 36.3 42.5 65 30PLUG-48B PLUG-48S 48 50 47.3 54.5 70 30
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• Specially modified polyolefin• Excellent fire safety characteristics• Self-extinguishing properties• Very good insulating characteristics• Very good flexibility• Impact resistance• Free from halogens and cadmium• Temperature range: –25 °C to +95 °C• Chemical resistance: To strong acids and alkalies
• Speziell modifiziertes Polyolefin• Hervorragende Brandschutzeigenschaften• Selbstverlöschend• Sehr gute Isolationseigenschaften• Sehr gute Flexibilität• Schlag- und trittfest• Halogen- und cadmiumfrei• Temperaturbereich: –25 °C bis +95 °C• Chemische Beständigkeit: Gegen starke Säuren und Basen
min.PLU-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
17For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Pro
POH very flexible, very supple, very high stability, medium, highest levels of fire and passenger safety sehr flexibel, sehr geschmeidig, sehr hohe Stabilität, mittelschwer, höchster Brand- und Personenschutz • For applications with highest fire safety performance requirements
• Für höchste Brand- und Personenschutzanforderungen
POHT-10B POHT-10S 10 12 9.2 13.0 13.0 50POHT-12B POHT-12S 12 16 11.8 15.8 15.8 50POHG-17B POHG-17S 17 20 15.7 21.2 21.2 50POHG-23B POHG-23S 23 25 22.0 28.5 28.5 50POHG-29B POHG-29S 29 32 27.4 34.4 34.4 50POHG-36B POHG-36S 36 40 35.8 42.4 42.4 30POHG-48B POHG-48S 48 50 46.8 54.5 54.5 30
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• Specially modified polyolefin• Excellent fire safety characteristics acc. to BS6853 1a (interior)• Self-extinguishing, • Free from halogens and cadmium• Easy layouting through high conduit ductility and formability• Very good flexibility• Very good insulating characteristics• Impact resistance• Temperature range: –25 °C to +95 °C; short-term +120 °C• Chemical resistance: To strong acids and alkalies
• Speziell modifiziertes Polyolefin• Hervorragende Brandschutzeigenschaften nach BS 6853 1a (Innenanwendung)• Selbstverlöschend• Halogen- und cadmiumfrei• Einfache Verlegung durch hohe Rohrgeschmeidigkeit und Formbarkeit• Sehr gute Isolationseigenschaften• Gute Flexibilität• Temperaturbereich: –25 °C bis +95 °C; kurzzeitig +120 °C• Chemische Beständigkeit: Gegen starke Säuren und Basen
min.POH-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Dimensions / Dimensionen in mm
18 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Pro
PSX flexible, light / flexibel, leicht• For applications with the highest fire safety performance requirements• For applications with extreme temperature conditions• For applications exposed to radiation
• Für höchste Brandschutzanforderungen• Bei extremen Temperaturanforderungen• Bei Anwendungen, die Strahlung ausgesetzt sind
PSXT-10B 10 12 9.8 13.0 20 50PSXT-12B 12 16 12.2 15.8 30 50PSXG-17B 17 20 15.8 21.2 40 50PSXG-23B 23 25 22.3 28.5 45 50PSXG-29B 29 32 28.0 34.5 55 50PSXG-36B 36 40 36.5 42.5 60 30PSXG-48B 48 50 47.5 54.5 70 30
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• Specially modified polyetherimide• Excellent fire safety characteristics• Self-extinguishing• Very good insulating characteristics• High radiation resistance• Good flexibility• Impact resistant• Low smoke density and toxicity• Free from halogens and cadmium• High impact strength also at low temperatures• Temperature range: –100 °C to +170 °C; Short-term to +200 °C• Chemical resistance: To oils, fats, acids, alcohols and hot water
• Speziell modifiziertes Polyetherimid• Hervorragende Brandschutzeigenschaften• Selbstverlöschend• Hervorragende Hochtemperatur- und Kälteeigenschaften• Halogen- und cadmiumfrei• Hohe Strahlungsbeständigkeit• Gute Flexibilität, • Schlag- und trittfest• Niedrige Rauchgasdichte und Toxizität• Temperaturbereich: –100 °C bis +170 °C; Kurzzeitig bis +200 °C• Chemische Beständigkeit: Gegen Oele, Fette, Säuren, Alkohole und heisses Wasser
min.PSX-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
19For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
CYL very flexible, medium / sehr flexibel, mittelschwer
ESD very flexible, medium / sehr flexibel, mittelschwer
• In machine building and installation industries • Im Maschinen- und Apparatebau
• For dynamic applications in robotics and automation where electrostatic charge and uncontrolled discharge need to be avoided
• Für dynamische Anwendungen im Roboterbau und in der Automation wo elektrostatische Aufladung und unkontrollierte Entladung vermieden werden muss
CYLT-07B CYLT-07S 7 10 6.2 10.0 15 50CYLT-10B CYLT-10S 10 12 9.6 13.0 20 50CYLT-12B CYLT-12S 12 16 12.0 15.8 30 50CYLT-17B CYLT-17S 17 20 16.2 21.2 40 50CYLT-23B CYLT-23S 23 25 22.6 28.5 45 50CYLT-29B CYLT-29S 29 32 29.0 34.5 55 50CYLT-36B CYLT-36S 36 40 36.5 42.5 60 30CYLT-48B CYLT-48S 48 50 47.5 54.5 70 30CYLG-23B CYLG-23S 23 25 21.9 28.5 45 50CYLG-29B CYLG-29S 29 32 27.6 34.5 55 50CYLG-36B CYLG-36S 36 40 36.0 42.5 60 30CYLG-48B CYLG-48S 48 50 47.0 54.5 70 30CYLG-56B CYLG-56S 56 68 56.3 67.2 120 30CYLG-70B CYLG-70S 70 80 68.0 80.0 160 10CYLG-95B CYLG-95S 95 106 91.9 106.0 210 10CYLG-125B CYLG-125S 125 146 126.5 146.5 450 6
ESDT-07B 07 10 6.2 10.0 15 50ESDT-10B 10 12 9.6 13.0 20 50ESDT-12B 12 16 12.0 15.8 30 50ESDT-17B 17 20 16.4 21.1 40 50ESDT-23B 23 25 22.6 28.4 45 50ESDT-29B 29 32 29.0 34.3 55 50ESDT-36B 36 40 36.5 42.5 60 30ESDT-48B 48 50 47.5 54.5 70 30ESDG-56B 56 68 56.5 67.0 110 30ESDG-70B 70 80 67.5 80.0 150 10ESDG-95B 95 106 91.5 106.0 170 10
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• High grade, specially formulated polyamide 6• Very good flexibility• Good impact strength also at low temperatures and dry conditions• Self-extinguishing• Free from halogens and cadmium• Temperature range: –40 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell formuliertes Polyamid 6• Sehr gute Flexibillität• Gute Schlagfestigkeit auch bei tiefen Temperaturen und Trockenheit• Selbstverlöschend• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
• High-grade, specially modified polyamide 12• Prevents electrostatic charging• For indoor and outdoor use (very good cold temperature performance)• Excellent UV-resistance and high dynamic load resistance• Free from halogens and cadmium• Temperature range: –40 °C to +90 °C; Short-term to +150 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 12• Nicht elektrostatisch aufladend• Für Innen- und Ausseneinsatz (sehr gute Kälteeigenschaften)• Hervorragende UV-Beständigkeit und hohe dynamische Belastbarkeit• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +90 °C; Kurzzeitig bis +150 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, Säuren u.a.
min.CYL-Index
max.
min.ESD-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
20 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
PCL very flexible, medium / sehr flexibel, mittelschwer
PCS highly flexible, heavy / hochflexibel, schwer
• In machine building, installation and vehicle building applications
• Im Maschinen- / Apparatebau und in der Fahrzeugindustrie
• Dynamic installations in railway vehicles• External applications, e.g. solar systems, signalling, CCTV
• Dynamische Verlegung bei Schienenfahrzeugen• Aussenanwendungen z.B. Solar-Systeme, Signalisationen, Videoüberwachungen
PCLT-07B PCLT-07S 7 10 6.2 10.0 15 50PCLT-10B PCLT-10S 10 12 9.6 13.0 20 50PCLT-12B PCLT-12S 12 16 12.0 15.8 30 50PCLT-17B PCLT-17S 17 20 16.2 21.2 40 50PCLT-23B PCLT-23S 23 25 22.6 28.5 45 50PCLT-29B PCLT-29S 29 32 29.0 34.5 55 50PCLT-36B PCLT-36S 36 40 36.5 42.5 60 30PCLT-48B PCLT-48S 48 50 47.5 54.5 70 30PCLG-17B PCLG-17S 17 20 15.3 21.2 40 50PCLG-23B PCLG-23S 23 25 21.9 28.5 45 50PCLG-29B PCLG-29S 29 32 27.6 34.5 55 50PCLG-36B PCLG-36S 36 40 36.0 42.5 60 30PCLG-48B PCLG-48S 48 50 47.0 54.5 70 30PCLG-56B PCLG-56S 56 68 56.3 67.2 130 30PCLG-70B PCLG-70S 70 80 67.5 80.0 160 10PCLG-95B PCLG-95S 95 106 91.5 106.0 210 10 PCLG-125B PCLG-125S 125 146 126.5 146.5 450 6
PCST-07B PCST-07S 7 10 6.0 10.0 15 / 40 50PCST-10B PCST-10S 10 12 9.2 13.0 20 / 50 50PCST-12B PCST-12S 12 16 11.8 15.8 25 / 70 50PCST-17B PCST-17S 17 20 16.0 21.2 35 / 80 50PCSG-17B PCSG-17S 17 20 15.2 21.2 35 / 85 50PCSG-23B PCSG-23S 23 25 21.5 28.5 40 / 110 50PCSG-29B PCSG-29S 29 32 27.7 34.4 50 / 130 30PCSG-36B PCSG-36S 36 40 35.8 42.4 60 / 180 30PCSG-48B PCSG-48S 48 50 46.8 54.4 70 / 220 30PCSG-56B PCSG-56S 56 68 56.1 67.2 130 / 280 30PCSG-70B PCSG-70S 70 80 66.5 80.0 170 / 360 10PCSG-95B PCSG-95S 95 106 91.0 106.0 250 / 470 10
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**/dyn.***Radius
VEMeter
• Specially modified polyamide 6/6.6 for cold impact• Very good flexibility• Self-extinguishing• Free from halogens and cadmium• High impact strength also at low temperatures• Temperature range: –50 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Speziell kälteschlagzähmodifiziertes Polyamid 6/6.6• Sehr gute Flexibilität • Selbstverlöschend• Halogen- und cadmiumfrei• Hohe Schlagfestigkeit auch bei tiefen Temperaturen• Temperaturbereich: –50 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
• High-grade, specially modified polyamide 12• Excellent resistance to ultra violet rays and weathering• Excellent flexibility and self-extinguishing• Good mechanical strength at low temperatures and dry conditions• Free from halogens and cadmium• Temperature range: –50 °C to +95 °C; Short-term to +150 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 12• Höchste UV- und Witterungsbeständigkeit• Hervorragende Flexibilität und selbstverlöschend• Gute mechanische Festigkeit bei tiefen Temperaturen und Trockenheit• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +95 °C; Kurzzeitig bis +150 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
min.PCL-Index
max.
min.PCS-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
21For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
PCSL very flexible, medium / sehr flexibel, mittelschwer• Dynamic installations in railway vehicles• External applications, e.g. solar systems, signalling, CCTV
• Dynamische Verlegung bei Schienenfahrzeugen• Aussenanwendungen z.B. Solar-Systeme, Signalisationen, Videoüberwachungen
PCSLT-07B PCSLT-07S 7 10 6.2 10.0 15 50PCSLT-10B PCSLT-10S 10 12 9.6 13.0 20 50PCSLT-12B PCSLT-12S 12 16 11.9 15.8 25 50PCSLT-17B PCSLT-17S 17 20 16.4 21.1 30 50PCSLG-17B PCSLG-17S 17 20 15.2 21.1 30 50PCSLG-23B PCSLG-23S 23 25 21.7 28.4 40 50PCSLG-29B PCSLG-29S 29 32 27.4 34.3 50 50PCSLG-36B PCSLG-36S 36 40 35.8 42.3 60 30PCSLG-48B PCSLG-48S 48 50 46.7 54.2 70 30
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• High-grade, specially modified polyamide 12• Excellent resistance to ultra violet rays and weathering• Excellent flexibility• Good mechanical strength at low temperatures and dry conditions• Self-extinguishing properties• Free from halogens and cadmium• Temperature range: –50 °C to +95 °C; Short-term to +150 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 12• Höchste UV- und Witterungsbeständigkeit• Hervorragende Flexibilität• Gute mechanische Festigkeit bei tiefen Temperaturen und Trockenheit• Selbstverlöschend• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +95 °C; Kurzzeitig bis +15 0 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
min.PCSL-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Dimensions / Dimensionen in mm
22 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
PEL highly flexible, light/soft / hochflexibel, leicht/weich• In electrical cabinets and appliance construction • Im Schaltschrank- und Gerätebau
PELT-10S PELT-10SL 10 12 9.7 12.7 20 50PELT-12S PELT-12SL 12 16 11.5 15.5 30 50PELT-17S PELT-17SL 17 20 16.0 20.9 35 50PELT-23S PELT-23SL 23 25 22.5 27.5 40 50PELT-29S PELT-29SL 29 32 28.5 33.8 50 30PELT-36S PELT-36SL 36 40 34.0 41.6 60 30PELT-48S PELT-48SL 48 50 47.0 53.2 70 30
Order No.grey
Order No.grey, slitted
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.grau
Bestell-Nr.grau, geschlitzt
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.PEL-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
• Specially modified polyethylene• Self-extinguishing• Low stiffness• Temperature range: –50 °C to +60 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, acids etc.
• Speziell modifiziertes Polyethylen• Selbstverlöschend• Geringe Eigensteifigkeit• Temperaturbereich: –50 °C bis +60 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, Säuren u.a.
Dimensions / Dimensionen in mm
23For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
PIS/PIH highly flexible, medium and heavy hochflexibel, mittelschwer und schwer• For dynamic applications in robotics and automation
• Für dynamische Anwendungen im Roboter- und Automatenbau
PIST-07B PIST-07S 7 10 6.2 10.0 15 / 40 50PIST-10B PIST-10S 10 12 9.6 13.0 20 / 50 50PIST-12B PIST-12S 12 16 11.9 15.8 25 / 65 50PIST-17B PIST-17S 17 20 16.4 21.1 30 / 65 50PIST-23B PIST-23S 23 25 22.6 28.4 35 / 90 50PIST-29B PIST-29S 29 32 29.0 34.3 45 / 110 50PIST-36B PIST-36S 36 40 36.5 42.5 60 / 165 30PIST-48B PIST-48S 48 50 47.5 54.5 70 / 180 30PISG-17B PISG-17S 17 20 15.2 21.1 30 / 80 50PISG-23B PISG-23S 23 25 21.7 28.4 40 / 100 50PISG-29B PISG-29S 29 32 27.4 34.3 50 / 120 50PISG-36B PISG-36S 36 40 35.8 42.3 60 / 180 30PISG-48B PISG-48S 48 50 46.7 54.2 70 / 200 30PIHG-56B PIHG-56S 56 68 56.3 67.2 110 / 270 30PIHG-70B PIHG-70S 70 80 67.2 79.6 150 / 350 30PIHG-95B PIHG-95S 95 106 91.3 106.0 170 / 450 30PIHG-125B PIHG-125S 125 146 126.5 146.5 350 / 480 20
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**/dyn.***Radius
VEMeter
• High-grade, specially modified polyamide 12• PIS: medium-wall (nominal width 07 to 48) PIH: heavy-wall (nominal width 56 to 125)• Excellent resistance to ultra violet rays and weathering• Self-extinguishing• Excellent flexibility• Free from halogens and cadmium• Good mechanical strength at low temperatures and dry conditions • Temperature range: –50 °C to +95 °C; Short-term to +150 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc. • Hochwertiges, speziell modifiziertes Polyamid 12• PIS: mittelschwer (Nennweite 07 bis 48) PIH: schwer (Nennweite 56 bis 125)• Höchste UV- und Witterungsbeständigkeit• Selbstverlöschend• Hervorragende Flexibilität• Halogen- und cadmiumfrei• Gute mechanische Festigkeit bei tiefen Temperaturen und Trockenheit• Temperaturbereich: –50 °C bis +95 °C; Kurzzeitig bis +150 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
min.PIS-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Dimensions / Dimensionen in mm
24 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
POS very flexible, medium / sehr flexibel, mittelschwer
PUE highly flexible, medium / hochflexibel, mittelschwer
• In automation as well as in machine building and industrial installations, especially where continuous movements occur
• In der Automation sowie im Maschinen- und Apparatebau, speziell für dynamische Anwendungen
• For dynamic applications in robotics and automation • Für dynamische Anwendungen im Roboter- und Automatenbau
POST-10B 10 12 9.6 13.0 20 50POST-12B 12 16 11.9 15.8 30 50POST-17B 17 20 16.2 21.2 35 50POST-23B 23 25 22.6 28.5 40 50POST-29B 29 32 29.0 34.5 50 50POST-36B 36 40 36.5 42.5 60 30POST-48B 48 50 47.5 54.5 70 30POSG-29B 29 32 27.6 34.5 50 50POSG-36B 36 40 36.0 42.5 60 30POSG-48B 48 50 47.0 54.5 70 30POSG-70B 70 80 67.2 79.6 150 30POSG-95B 95 106 91.3 106.0 170 30
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**/dyn.***Radius
VEMeter
min.POS-Index
max.
min.PUE-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially modified polyolefin• Excellent reversed bending performance and flexibility• Very good insulating characteristics• Good impact resistance• Free from halogens and cadmium• Temperature range: –25 °C to +95 °C; Short-term to +130 °C• Chemical resistance: strong acids
• Hochwertiges, speziell modifiziertes Polyolefin• Hervorragendes Biegewechselverhalten und Flexibilität• Sehr gute Isolationseigenschaften• Gute Schlagzähigkeit• Halogen- und cadmiumfrei• Temperaturbereich: –25 °C bis +95 °C; Kurzzeitig bis +13 0 °C• Chemische Beständigkeit: starke Säuren
• Specially modified polyurethane• Free from halogens and cadmium• Excellent chafing properties• Temperature range: –60 °C to +50 °C• Chemical resistance: To fuels, mineral oils and fats etc.
• Speziell modifiziertes Polyurethan• Halogen- und cadmiumfrei• Hervorragende Abriebeigenschaften• Temperaturbereich: –60 °C bis +50 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette u.a.
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
PUET-23B 23 25 22.4 28.5 35 / 70 50PUET-29B 29 32 28.8 34.5 40 / 90 30PUET-36B 36 40 35.8 42.4 50 / 120 30PUET-48B 48 50 48.6 54.5 60 / 130 21PUEG-56B 56 68 56.3 67.2 90 / 170 30PUEG-70B 70 80 68.2 80.5 100 / 220 30
25For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
PVD pliable, medium / biegbar, mittelschwer• In machine building applications with long-term high temperature requirements as well as in the chemical and food industries
• Im Maschinenbau bei erhöhten Temperaturanforderungen wie auch in der chemischen und Lebensmittelindustrie
PVDT-10P 10 12 9.5 12.6 10 50PVDT-12P 12 16 11.8 15.5 30 50PVDT-17P 17 20 16.0 20.8 40 50PVDT-23P 23 25 22.6 28.0 45 50PVDT-29P 29 32 29.0 34.1 50 50
Order No.transparent
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.transparent
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
• Specially formulated PVDF• Excellent chemical resistance also at high temperatures • Self-extinguishing and free from cadmium• Excellent UV resistance and very good abrasion resistance• High stiffness• Temperature range: –60 °C to +150 °C• Excellent chemical resistance: To fuels, mineral oils, fats, alkalies, strong acids etc. • Speziell formuliertes PVDF• Hervorragende Chemikalienbeständigkeit auch bei hohen Temperaturen• Hervorragende UV-Beständigkeit und sehr hohe Abriebfestigkeit• Selbstverlöschend und cadmiumfrei • Hohe Eigensteifigkeit• Temperaturbereich: –60 °C bis +150 °C• Hervorragende chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, starke Säuren u.a.
min.PVD-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
26 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
VAM flexible, heavy / flexibel, schwer• In passenger areas of railway vehicles• Excellent fire safety characteristics allow application in public buildings like hospitals, hotels, airports, train and subway stations, shopping centers etc.
• In Passagierzonen im Schienenfahrzeugbau • Aufgrund hoher Personenschutzeigenschaften im Brandfall auch anwendbar in öffentlichen Gebäuden wie Spitälern, Hotels, Flughäfen, Bahn- und U-Bahnstationen, Einkaufszentren, etc.
VAMT-07B VAMT-07S 7 10 6.0 10.0 20 50VAMT-10B VAMT-10S 10 12 9.2 13.0 25 50VAMT-12B VAMT-12S 12 16 11.8 15.8 30 50VAMT-17B VAMT-17S 17 20 16.0 21.2 40 50VAMG-17B VAMG-17S 17 20 15.2 21.2 40 50VAMG-23B VAMG-23S 23 25 22.0 28.5 50 50VAMG-29B VAMG-29S 29 32 27.7 34.4 60 50VAMG-36B VAMG-36S 36 40 35.8 42.4 70 30VAMG-48B VAMG-48S 48 50 46.8 54.4 80 30
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.VAM-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially formulated polyamide 6• Good resistance to ultra violet rays and weathering• High impact and compression strength• High stiffness• Free from halogens and cadmium• Outstanding self-extinguishing characteristics• Minimal development of smoke and gases• Temperature range: –40 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 6• Gute UV- und Witterungsbeständigkeit• Hohe Eigensteifigkeit• Hohe Schlag- und Trittfestigkeit• Äusserst geringe Rauchgasentwicklung• Hervorragend selbstverlöschend• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
27For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
VAML flexible, heavy / flexibel, schwer• In passenger areas of railway vehicles• Excellent fire safety characteristics allow application in public buildings like hospitals, hotels, airports, train and subway stations, shopping centers etc.
• In Passagierzonen im Schienenfahrzeugbau • Aufgrund hoher Personenschutzeigenschaften im Brandfall auch anwendbar in öffentlichen Gebäuden wie Spitälern, Hotels, Flughäfen, Bahn- und U-Bahnstationen, Einkaufszentren, etc.
VAMLT-07B VAMLT-07S 7 10 6.2 10.0 15 50VAMLT-10B VAMLT-10S 10 12 9.6 13.0 20 50VAMLT-12B VAMLT-12S 12 16 12.0 15.8 30 50VAMLG-17B VAMLG-17S 17 20 15.3 21.2 40 50VAMLG-23B VAMLG-23S 23 25 22.6 28.5 45 50VAMLG-29B VAMLG-29S 29 32 27.6 34.5 55 50VAMLG-36B VAMLG-36S 36 40 36.0 42.5 65 30VAMLG-48B VAMLG-48S 48 50 47.0 54.5 75 30VAMLG-56B VAMLG-56S 56 68 56.3 67.2 140 30VAMLG-70B VAMLG-70S 70 80 67.5 80.0 160 10VAMLG-95B VAMLG-95S 95 106 91.5 106.0 210 10VAMLG-125B VAMLG-125S 125 146 126.0 146.5 450 6
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.VAML-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Specially modified polyamide 6 • Good impact strength• Good resistance to ultra violet rays and weathering• Outstanding self-extinguishing characteristics• Minimal development of smoke and gases• Free from halogens and cadmium• Temperature range: –40 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Speziell modifiziertes Polyamid 6 • Gute Schlagfestigkeit• Gute UV- und Witterungsbeständigkeit• Hervorragend selbstverlöschend• Äusserst geringe Rauchgasentwicklung• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Dimensions / Dimensionen in mm
28 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
VCS flexible, heavy / flexibel, schwer• External applications, static installations in railway vehicles
• Aussenanwendungen, statische Verlegung bei Schienenfahrzeugen
VCST-07B VCST-07S 7 10 6.0 10.0 20 100VCST-10B VCST-10S 10 12 9.2 13.0 25 50VCST-12B VCST-12S 12 16 11.8 15.8 30 50VCST-17B VCST-17S 17 20 16.0 21.2 40 50VCSG-17B VCSG-17S 17 20 15.2 21.2 40 50VCSG-23B VCSG-23S 23 25 22.0 28.5 50 50VCSG-29B VCSG-29S 29 32 27.7 34.4 60 50VCSG-36B VCSG-36S 36 40 35.8 42.4 70 30VCSG-48B VCSG-48S 48 50 46.8 54.4 80 30VCSG-56B VCSG-56S 56 68 56.1 67.2 150 30VCSG-70B VCSG-70S 70 80 66.5 80.0 200 10VCSG-95B VCSG-95S 95 106 91.0 106.0 300 10
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.VCS-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially formulated polyamide 6 • Very good resistance to ultra violet rays and weathering• Good flexibility• Self-extinguishing• High compression and impact strengths at low temperature and low humidity• Free from halogens and cadmium• Temperature range: –50 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 6• Sehr gute UV- und Witterungsbeständigkeit• Gute Flexibilität • Selbstverlöschend• Hohe Druck- und Schlagfestigkeit bei tiefen Temperaturen und Trockenheit• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Dimensions / Dimensionen in mm
29For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX
VOH pliable, very heavy / biegbar, sehr schwer• In exterior machine connections, for heavy machine equipment • Rohrverlegung ausserhalb von Maschinen, im schweren
Anlagenbau
VOHD-07B VOHD-07S 7 10 5.8 10.0 30 50VOHD-10B VOHD-10S 10 12 9.0 13.0 35 50VOHD-12B VOHD-12S 12 16 11.6 15.8 40 50VOHG-17B VOHG-17S 17 20 14.5 21.0 60 50VOHG-23B VOHG-23S 23 25 21.1 28.5 70 50VOHG-29B VOHG-29S 29 32 26.6 34.5 80 50VOHG-36B VOHG-36S 36 40 35.0 42.5 90 30VOHG-48B VOHG-48S 48 50 46.5 54.5 100 30VOHG-56B VOHG-56S 56 68 55.5 67.2 135 10VOHG-70B VOHG-70S 70 80 67.0 80.0 200 10VOHG-95B VOHG-95S 95 106 90.5 106.0 300 10VOHG-125B VOHG-125S 125 146 126.0 146.5 480 6
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.VOH-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade specially modified polyamide 6• High degree of mechanical protection and outstanding pull-out resistance• For exterior applications in machinery and installations from nominal width 17 according to UL standards• Self-extinguishing• Robust construction• Free from halogens and cadmium• Temperature range: –40 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 6• Höchster mechanischer Schutz und ausgezeichnete Ausreissfestigkeit• Für Aussenverlegung an Maschinen und Anlagen ab Nennweite 17 nach UL Standards• Halogen- und cadmiumfrei• Robuste Bauweise• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
30 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Multilayer / Mehrschicht
XPCL highly flexible, medium / hochflexibel, mittelschwer• In machine building and equipment with high requirements • Im Maschinen- und Apparatebau mit erhöhten Anforderungen
XPCLT-10BB XPCLT-10SB 10 12 9.6 13.0 20 50XPCLT-12BB XPCLT-12SB 12 16 11.8 15.6 30 50XPCLT-17BB XPCLT-17SB 17 20 16.6 21.0 40 50XPCLG-17BB XPCLG-17SB 17 20 15.6 20.9 40 50XPCLG-23BB XPCLG-23SB 23 25 21.9 28.5 45 50XPCLG-29BB XPCLG-29SB 29 32 27.6 34.5 55 50XPCLG-36BB XPCLG-36SB 36 40 36.0 42.5 60 30XPCLG-48BB XPCLG-48SB 48 50 47.0 54.5 70 30
Order No.black/blue
Order No.grey/blue
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz/blau
Bestell-Nr.grau/blau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.XPCL-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Outer layer: high-grade, specially formulated polyamide 6• Intermediate layer: spec. bonding compound• Inner layer: specially modified polyolefin• Self-extinguishing• Very long life time, 15-20 years for standard applications• Easy cable inseration, low friction inner layer• Impermeable to water and steam • Excellent flexibility• Good mechanical strength even at low temperatures and low humidity• Temperature range: –50 °C to +105 °C; Short-term to +160 °C
• Aussenschicht: hochwertiges, speziell formuliertes Polyamid 6• Mittelschicht: spez. Haftungscompound• Innenschicht: speziell modifiziertes Polyolefin• Sehr lange Lebensdauer, 15-20 Jahre bei Standard-Anwendungen• Erleichtertes Einziehen durch innere Gleitschicht• Wasser- und wasserdampfundurchlässig• Hervorragende Flexibilität• Gute mechanische Festigkeit auch bei tiefen Temperaturen und Trockenheit• Selbstverlöschend• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +105 °C; Kurzzeitig bis +160 °C.
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
31For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Multilayer / Mehrschicht
XSOL highly flexible, medium / hochflexibel, mittelschwer• All-purpose, especially in long-term external applications, e.g. energy technology, transportation
• Universell einsetzbar, besonders für Langzeit- Aussenanwendungen, z.B. Energietechnik, Verkehrswesen
XSOLT-10BG 10 12 9.6 13.0 25 50XSOLT-12BG 12 16 11.8 15.6 30 50XSOLG-17BG 17 20 15.2 21.0 40 50XSOLG-23BG 23 25 22.0 28.5 50 50XSOLG-29BG 29 32 27.5 34.5 60 50XSOLG-36BG 36 40 35.8 42.4 70 30XSOLG-48BG 48 50 46.8 54.4 80 30
Order No.black/green
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz/grün
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.XSOL-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Outer layer: high-grade, specially formulated polyamide 12• Intermediate layer: spec. bonding compound• Inner layer: high-grade,specially modified polyamide 6• Very long life time, >20 – 30 years • Very good resistance to UV and weathering• Very high flexibility• Very good mechanical strength• High impact resistance at low temperature and humidity• Excellent fire safety characteristics• Excellent chemical resistance• Free from halogens and cadmium• Temperature range: –50 °C to +95 °C; Short-term to +150 °C
• Aussenschicht: hochwertiges, speziell formuliertes Polyamid 12• Mittelschicht: spez. Haftungscompound• Innenschicht: hochwertiges, speziell formuliertes Polyamid 6• Sehr lange Lebensdauer, >20 – 30 Jahre• Sehr gute UV- und Witterungsbeständigkeit• Sehr hohe Flexibilität• Sehr gute mechanische Festigkeit• Hohe Schlagzähigkeit bei tiefen Temperaturen und Trockenheit• Sehr gute Brandschutzeigenschaften• Sehr gute chemische Beständigkeit• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +95 °C; kurzzeitig bis +150 °C
Dimensions / Dimensionen in mm
32 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Multilayer / Mehrschicht
XSOLL highly flexible, medium / hochflexibel, mittelschwer• All-purpose, especially in long-term external applications, e.g. energy technology, transportation
• Universell einsetzbar, besonders für Langzeit- Aussenanwendungen, z.B. Energietechnik, Verkehrswesen
XSOLLT-12BG 12 16 11.8 15.8 50 50XSOLLG-17BG 17 20 15.2 21.2 50 50XSOLLG-23BG 23 25 22.0 28.5 50 50XSOLLG-29BG 29 32 27.7 34.4 50 50XSOLLG-36BG 36 40 35.8 42.4 30 30XSOLLG-48BG 48 50 46.8 54.4 30 30
min.XSOLL-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Outer layer: high-grade, specially formulated polyamide 12• Intermediate layer: spec. bonding compound• Inner layer: high-grade, specially modified polyamide 6• Very long life time, >20 years • Very good resistance to UV and weathering• High flexibility and very good mechanical strength• High impact resistance at low temperature and humidity• Good fire safety characteristics• Excellent chemical resistance• Free from halogens and cadmium• Temperature range: –40 °C to +95 °C; Short-term to +150 °C
• Aussenschicht: hochwertiges, speziell formuliertes Polyamid 12• Mittelschicht: spez. Haftungscompound• Innenschicht: hochwertiges, speziell formuliertes Polyamid 6• Sehr lange Lebensdauer, >20 Jahre• Sehr gute UV- und Witterungsbeständigkeit• Hohe Flexibilität und s ehr gute mechanische Festigkeit• Hohe Schlagzähigkeit bei tiefen Temperaturen und Trockenheit• Gute Brandschutzeigenschaften• Sehr gute chemische Beständigkeit• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +95 °C; Kurzzeitig bis +150 °C.
Order No.black/green
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz/grün
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Dimensions / Dimensionen in mm
33For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMAFLEX Multilayer / Mehrschicht
XVCS1H flexible, heavy / flexibel, schwer• Track side applications • Gleisnebenanwendungen
XVCS1H-12BG 12 16 11.7 15.5 30 50XVCS1H-17BG 17 20 15.2 21.0 40 50XVCS1H-23BG 23 25 21.7 28.4 50 50XVCS1H-29BG 29 32 27.5 34.3 60 50XVCS1H-36BG 36 40 35.8 42.2 70 30XVCS1H-48BG 48 50 46.8 54.3 80 30
Order No.black/green
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz/grün
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
min.XVCS1H-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Outer layer: high-grade, specially formulated polyamide 6• Inner layer: specially modified polyolefin• Very long life time, >20 years• Excellent cold temperature performance• Easy layouting through: - high conduit ductility and formability - low friction inner layer facilitates cable insertion• Very good resistance to ultra violet rays and weathering• Very good mechanical strength while simultaneously highly flexible• Impermeable to water and steam • Temperature range: –50 °C to +90 °C; Short-term to +120 °C
• Aussenschicht: hochwertiges, speziell formuliertes Polyamid 6• Innenschicht: speziell modifiziertes Polyolefin• Sehr lange Lebensdauer, >20 Jahre • Hervorragende Kälteeigenschaften• Einfache Verlegung durch: - hohe Rohrgeschmeidigkeit und Formbarkeit - geringe Kabelreibung durch innere Gleitschicht• Sehr gute UV- und Witterungsbeständigkeit• Sehr gute mechanische Festigkeiten bei gleichzeitig hoher Flexibilität• Wasser- und wasserdampfundurchlässig• Temperaturbereich: –50 °C bis +90 °C; kurzzeitig bis +120 °C
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
34 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA FLEXPLus
CUS flexible, heavy / flexibel, schwer
PUS very flexible, heavy / sehr flexibel, schwer
• In machine building and installation industries• In electrical installations
• Im Maschinen- und Appartebau• In Elektroinstallationen
• Long-term external applications, e.g. solar systems, signalling, CCTV• Dynamic applications
• Langzeit-Aussenanwendungen z.b. Solar-Systeme, Signalisationen und Videoüberwachungen• Dynamische Anwendungen
CUSG-17B CUSG-17S 17 20 16.2 21.2 40 31/100CUSG-23B CUSG-23S 23 25 21.9 28.5 45 31/100CUSG-29B CUSG-29S 29 32 27.6 34.4 55 31/100CUSG-36B CUSG-36S 36 40 36.0 42.4 60 31/100CUSG-48B CUSG-48S 48 50 47.0 54.4 70 31/100
PUSG-17B PUSG-17S 17 20 15.2 21.2 35 / 85 31/100PUSG-23B PUSG-23S 23 25 22.0 28.5 40 / 110 31/100PUSG-29B PUSG-29S 29 32 27.7 34.4 50 / 130 31/100PUSG-36B PUSG-36S 36 40 35.8 42.4 60 / 180 31/100PUSG-48B PUSG-48S 48 50 46.8 54.4 70 / 220 31/100
min.CUS-Index
max.
min.PUS-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially modified polyamide 6• Cost-effective• Very good flexibility• Good impact strength also at low temperatures and dry conditions• Self-extinguishing• Free from halogens and cadmium• Temperature range: –40 °C to +105 °C; Short-term to +160 °C
• Hochwertiges, speziell modifiziertes Polyamid 6• Kostengünstig• Sehr gute Flexibilität• Gute Schlagzähigkeit auch bei tiefen Temperaturen und Trockenheit• Selbstverlöschend • Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C.
• High-grade, specially modified polyamide 12• Excellent resistance to ultra violet rays and weathering• Excellent flexibility and self-extinguishing• Good mechanical strength at low temperatures and dry conditions• Free from halogens and cadmium• Temperature range: –50 °C to +95 °C; Short-term to +150 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 12• Höchste UV- und Witterungsbeständigkeit• Hervorragende Flexibilität und selbstverlöschend• Halogen- und cadmiumfrei• Gute mechanische Festigkeit bei tiefen Temperaturen und Trockenheit• Temperaturbereich: –50 °C bis +95 °C; Kurzzeitig bis +150 °C • Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter/ft
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter/Fuss
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter/ft
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**/dyn.***Radius
VEMeter/Fuss
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
35For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA FLEXPLus
VUS flexible, heavy / flexibel, schwer• For high requirements in machine building and plant construction• Where high compression resistance is required • For external applications
• Für hohe Anforderungen im Maschinen- und Anlagenbau• Wo hoher Trittschutz erforderlich ist• Für Aussenanwendungen
VUSG-17B VUSG-17S 17 20 15.2 21.2 40 31/100VUSG-23B VUSG-23S 23 25 22.0 28.5 50 31/100VUSG-29B VUSG-29S 29 32 27.7 34.4 60 31/100VUSG-36B VUSG-36S 36 40 35.8 42.4 70 31/100VUSG-48B VUSG-48S 48 50 46.8 54.4 80 31/100
min.VUS-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially modified polyamide 6• Very good resistance to ultra violet rays and weathering• Good flexibility• Self-extinguishing• High mechanical strength at low temperatures and low humidity• Free from halogens and cadmium• Temperature range: –50 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Hochwertiges, speziell modifiziertes Polyamid 6• Sehr gute UV- und Witterungsbeständigkeit• Gute Flexibilität• Selbstverlöschend• Hohe mechanische Festigkeit bei tiefen Temperaturen und Trockenheit• Halogen- und cadmiumfrei• Temperaturbereich: –50 °C bis +105 °C; Kurzzeitig bis +160 °C • Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a..
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter/ft
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter/Fuss
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
36 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA Divisible System / PMA Teilbares System
PACOF flexible, divisible / flexibel, teilbar• In machine building and plant construction • Im Maschinen- und Anlagenbau
PACOF-07B 07 10 5.6 10.0 30 50PACOF-10B 10 12 8.5 12.8 33 50PACOF-12B 12 16 11.0 15.6 35 50PACOF-14B - - 13.0 19.0 42 50PACOF-17B 17 20 15.5 21.1 45 50PACOF-20B - - 19.1 25.5 55 50PACOF-23B 23 25 22.1 28.4 70 50PACOF-26B - - 24.0 31.6 80 50PACOF-29B 29 32 27.2 34.5 120 50PACOF-36B 36 40 32.0 42.4 145 30PACOF-48B 48 50 43.9 54.1 150 30PACOF-70B 70 80 62.0 79.0 190 10
min.PACOF-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Specially modified polyamide 6• Easy installation and trouble-free retrofitting, applicable also for repairs • Can be opened and closed again in longitudinal direction any time• Self-extinguishing• Free from halogens and cadmium• Temperature range: –40 °C to +105 °C; Short-term to +160 °C• Chemical resistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• Speziell modifiziertes Polyamid 6• Einfachste Installation, problemlose Nachinstallation, geeignet zu Reparaturzwecken• Lässt sich in Längsrichtung jederzeit öffnen und wieder schliessen• Selbstverlöschend• Halogen- und cadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C• Chemische Beständigkeit: Gegen Kraftstoffe, Mineralöle, Fette, Alkalien, schwache Säuren u.a.
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
NEW /
NEU
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
37For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA Divisible System / PMA Teilbares System
PPCOF flexible, divisible / flexibel, teilbar• In machine building and plant construction • Im Maschinen- und Anlagenbau
PPCOF-07B 07 10 5.9 10.0 25 50PPCOF-10B 10 12 8.5 12.8 28 50PPCOF-12B 12 16 11.0 15.6 35 50PPCOF-14B - - 13.0 19.0 40 50PPCOF-17B 17 20 15.1 21.1 45 50PPCOF-20B - - 19.6 25.5 55 50PPCOF-23B 23 25 22.1 28.4 60 50PPCOF-26B - - 24.0 31.6 65 50PPCOF-29B 29 32 26.6 34.5 100 50PPCOF-36B 36 40 31.8 42.4 120 30PPCOF-48B 48 50 43.9 54.1 140 30PPCOF-70B 70 80 60.5 78.0 200 10
min.PPCOF-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Specially modified polypropylene PP• Easy installation and trouble-free retrofitting, applicable also for repairs • Can be opened and closed again in longitudinal direction any time• Temperature range: –20 °C to +105 °C; Short-term to +150 °C• Chemical resistance: To fuels, fats, alkalies, acids etc.
• Speziell modifiziertes Polypropylen PP• Einfachste Installation, problemlose Nachinstallation, geeignet zu Reparaturzwecken• Lässt sich in Längsrichtung jederzeit öffnen und wieder schliessen• Temperaturbereich: –20 °C bis +105 °C; Kurzzeitig bis +150 °C • Chemische Beständigkeit: Gegen Kraftstoffe, Fette, Alkalien, Säuren u.a..
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
NEW / NEU
Dimensions / Dimensionen in mm
38 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA Smart Line
LLPA very flexible, medium / sehr flexibel, mittelschwer
LLPF flexible, medium / flexibel, mittelschwer
• In machine building, installation and construction industries • Im Maschinen- und Apparatebau, in der Installationstechnik
• In machine building, installation and construction industries • Im Maschinen- und Apparatebau, in der Installationstechnik
LLPA-07* 07 10 T 6.2 10.0 15 50LLPA-10* 10 12 T 9.6 13.0 20 50LLPA-12* 12 16 T 12.0 15.8 30 50LLPA-17* 17 20 T 16.2 21.2 40 50LLPA-23* 23 25 T 22.6 28.5 45 50LLPA-29* 29 32 T 29.0 34.5 55 50LLPA-36* 36 40 T 36.5 42.5 60 30LLPA-48* 48 50 T 47.5 54.5 70 30
LLPF-07* 07 10 T 6.2 10.0 15 50LLPF-10* 10 12 T 9.6 13.0 20 50LLPF-12* 12 16 T 12.0 15.8 30 50LLPF-17* 17 20 T 16.2 21.2 40 50LLPF-23* 23 25 T 22.6 28.5 45 50LLPF-29* 29 32 T 29.0 34.5 55 50
LLPAG-17* 17 20 G 15.8 21.2 40 50LLPAG-23* 23 25 G 21.9 28.5 45 50LLPAG-29* 29 32 G 27.6 34.5 55 50LLPAG-36* 36 40 G 36.0 42.5 60 30LLPAG-48* 48 50 G 47.0 54.5 70 30LLPAG-56* 56 50 G 56.3 67.2 120 30LLPAG-70* 70 50 G 68.0 80.0 160 10LLPAG-95* 95 50 G 91.9 106.0 210 10LLPAG-125* 125 50 G 126.5 146.5 450 06
LLPFG-17* 17 20 G 15.8 21.2 40 50LLPFG-23* 23 25 G 21.9 28.5 45 50LLPFG-29* 29 32 G 27.6 34.5 55 50LLPFG-36* 36 40 G 36.0 42.5 60 30LLPFG-48* 48 50 G 47.0 54.5 70 30
min.LLPA-Index
max.
min.LLPF-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• High-grade, specially modified polyamide 6• Free from halogens and cadmium• Very good impact strength and flexibility• Temperature range: –40 °C to +105 °C; Short-term to +160 °C
• Hochwertiges, speziell modifiziertes Polyamid 6• Halogen- und cadmiumfrei• Sehr gute Schlagfestigkeit und Flexibilität• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C
• High-grade, specially modified polyamide 6• Free from halogens and cadmium• Good pressure resistance• Very good flammability characteristics• Temperature range: –40 °C to +105 °C; Short-term to +160 °C
• Hochwertiges, speziell modifiziertes Polyamid 6• Halogen- und cadmiumfrei• Gute Druckfestigkeit• Sehr gute Brandschutzeigenschaften• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +160 °C
Order No. Conduit size NW
Conduit sizemetric
Profile Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr. RohrgrösseNW
Rohrgrössemetrisch
Profil Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Order No. Conduit size NW
Conduit sizemetric
Profile Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr. RohrgrösseNW
Rohrgrössemetrisch
Profil Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
* = Replace with “A” to order black or “S” to order grey / * = Ersetzen Sie “A” für schwarz oder “S” für grau
* = Replace with “A” to order black or “S” to order grey / * = Ersetzen Sie “A” für schwarz oder “S” für grau
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
39For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Conduits / Wellrohre
PMA Smart Line
LLPO very flexible, light / sehr flexibel, leicht• In machine building, installation and vehicle construction • Im Maschinen- und Apparatebau, in der Fahrzeugindustrie
LLPO-07* 07 10 T 6.2 10.0 15 50LLPO-10* 10 12 T 9.6 13.0 20 50LLPO-12* 12 16 T 12.0 15.8 30 50LLPO-17* 17 20 T 16.2 21.2 40 50LLPO-23* 23 25 T 22.6 28.5 45 50LLPO-29* 29 32 T 29.0 34.5 55 50LLPO-36* 36 40 T 36.5 42.5 60 30LLPO-48* 48 50 T 47.5 54.5 70 30
min.LLPO-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Specially modified polyolefin• Free from halogens and cadmium• Very good flexibility• Good flammability characteristics• Very good resistance against acids• Temperature range: –20 °C to +90 °C; Short-term to +130 °C
• Speziell modifiziertes Polyoleinf• Halogen- und cadmiumfrei• Sehr gute Wechselbiegeeigenschaften• Gute Brandschutzeigenschaften• Sehr gute Säurebeständigkeit• Temperaturbereich: –20 °C bis +90 °C; Kurzzeitig bis +130 °C
Order No. Conduit size NW
Conduit sizemetric
Profile Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr. RohrgrösseNW
Rohrgrössemetrisch
Profil Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
* = Replace with “A” to order black or “S” to order grey / * = Ersetzen Sie “A” für schwarz oder “S” für grau
Fine profile T / Feinprofil T Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius for static (fixed) installation.
** stat. R = kleinster empfohlener Biegeradius für statische (feste) Verlegung.
Coarse profile G / Grobprofil GHigh pull-out strengthHohe Ausreisskräfte
Dimensions / Dimensionen in mm
Connectors / Anschlüsse
PMAFIX Pro Introduction / Einführung
The extremely successful and technically proven PMAFIX System has been developed further to create the PMAFIX Pro product range. The new generation fittings are the product of experience gained over many years in the most varied application areas. The PMAFIX Pro has two components, an outer body and an inner sealing element. The sealing element functions both as a seal and as a locking mechanism providing all ingress protection grades up to IP68 and IP69K even in applications where there is long term continuous movement. PMAFIX Pro is manufactured by using multiple component injection moulding process.
Das millionenfach bewährte PMAFIX-System wurde zur Produkt-linie PMAFIX Pro weiterentwickelt. Die neueste Fitting-Generation vereint die besonderen Eigenschaften von PMAFIX mit den Erkenntnissen aus langjähriger Erfahrung in unterschiedlichsten Einsatzbereichen. Der PMAFIX Pro besteht aus einem Aussen- körper und einem inneren Dichtelement. Das Dichtelement über-nimmt dabei die Funktionen Dichtung und Verriegelung in einem und gewährleistet alle Schutzarten bis zu IP68 und IP69K, selbst unter dauernder dynamischer Belastung. Die PMAFIX Pro Wellrohrverschraubungen werden in Mehrkom-ponenten-Spritzgusstechnik hergestellt.
● IP68 and IP69K static and dynamic ●Newest 2-component injection moulding technology●Highest international quality standards● Meets all ingress protection categories up to and including IP68 and IP69K even when the conduit connection is continually in motion●Simple “push-in” installation● Maximal assembly and operating safety●Recommended for PMAFLEX heavy duty conduits●Screwdriver required for dismantling, impeding unauthorised or accidental opening
●IP68 und IP69K statisch und dynamisch●Neuste Technologie●Höchste internationale Qualitätsstandards●Erfüllt alle IP-Dichtheitsklassen bis IP68 und IP69K, insbesondere auch für dynamisch bewegte Rohrverbindungen●Einfache Einstossmontage● Maximale Montage- und Betriebssicherheit●Empfohlen für PMAFLEX Hochleistungs-Rohre●Wiederöffnung nur mit Schraubenzieher möglich um zufälliges Öffnen zu verhindern
Next Generation Cable Protection Kabelschutz der nächsten Generation
PMAFIX Pro Key Features PMAFIX Pro Merkmale
40
41
Highest impact resistance through fully closed design● The perfectly symmetrical and fully enclosed fitting design prevents potentially increased impact stresses at edges and corners
All IP classes up to and including IP68 and IP69K – in static and dynamic applications ●Extra long ribbed sealing areas (cross linked material)● 360° locking and sealing element shields against high pressure water jets (up to 100 bar)
Highest pull out strength ●Highest pull out strength achieved through 360° grip on the conduit profile
Intelligent safety locking mechanism●Highest assembly reliability – the fitting only locks when the sealing element is fully inserted●Highest operational safety assured through visual and acoustic correct assembly controls
Connecting threads●Metric threads in both metal and polyamide
Integrated conduit supports● The conduit remains centralised with little deformation even when bent sharply directly at the fitting●Sealing up to and including IP68 and IP69K in static and dynamic applications also over long periods at high temperatures
Höchste Schlagsicherheit durch geschlossenes Design● Komplett symmetrisches und in sich geschlossenes Fittingdesign, dadurch keine Kerbwirkung bei Schlag beanspruchung
Alle Dichtheitsgrade bis und mit IP68 und IP69K – in statischen und dynamischen Anwendungen ●Extra lange Dichtflächen mit Lamellen (vernetzter Werkstoff)●Hochdruck-Wasserstrahlsperre (bis 100 bar) durch 360° Wellrohrabgriff
Höchste Ausreissfestigkeit●Höchste Ausreissfestigkeit durch 360° Eingriff ins Wellrohrprofil
Intelligente Sicherheitsverriegelung●Höchste Montagesicherheit – Verriegelung erfolgt erst, wenn das Dichtelement vollständig eingestossen ist● Höchste Betriebssicherheit durch visuelle und akustische Kontrollmerkmale
Gewindeanschlüsse●Metrische Metall- und Kunststoffgewinde
Integrierte Rohrabstützung●Wellrohr bleibt zentriert und formstabil, selbst bei starkem Abknicken unmittelbar nach der Verschraubung● Schutzart bis einschliesslich IP68 und IP69K in statischen und dynamischen Anwendungen auch bei langfristig erhöhten Temperaturen
Technical Details Technische Details
Connectors / Anschlüsse
Technical Details / Technische Details PMAFIX Pro
Up to 100 bar Bis 100 bar
42
Connectors / Anschlüsse
PMAFIX Pro Part Number Code / Nummernschlüssel
• Highestsealingthroughfullyclosedsystem• Forhighestdynamicapplications• Fitsanytypeofconduitprofile(TandG)• Excellentpull-outstrength• Re-openingforsafetyreasonsonlypossiblewitha screwdriver
• HöchsteDichtheitdurchgeschlossenesDesign• FürhöchstedynamischeBeanspruchungen• VerwendbarfürRohremitFein-undGrobprofil(TundG)• AusgezeichneteAusreissfestigkeit• ÖffnungzurSicherheitnurmitdemSchraubenzieher
Thread lengthGewindelänge
straight (N)gerade (N)
45° elbow (A)45° Winkel (A)
90° curved elbow (B)90° Bogenwinkel (B)
female thread (I)Innengewinde (I)
Modes of Ingress Protection / Schutzart: H = IP69K, with thread seal / mit Gewindedichtung S = IP69K, on conduit side / rohrseitig
Thread size (Table 2)Gewindegrösse (Tabelle 2)
Type/Typ: PMAFIX Pro
Nominal width conduit (Table 1)Nennweite Wellrohr (Tabelle 1)
Series / Bauformen: N = straight / gerade A = 45° elbow / 45° Winkel B = 90° curved elbow / 90° Bogenwinkel I = female thread / Innengewinde
Thread type / Gewindeart:M = metric thread / metrisches Feingewinde U = UNEF round connector / UNEF Rundsteckergewinde
Colours / Farben: N = black with metal thread / schwarz mit Metallgewinde M = grey with metal thread / grau mit Metallgewinde B = black / schwarz
Static and Dynamic / Statisch und Dynamisch IP68 + IP69K
N K N H – – M 20 7 10
Patent / Patentiert
Connector SeriesAnschlussarmaturen-Baureihen
Connectors: Part Number Code / Anschlüsse: Nummernschlüssel
43
Connectors / Anschlüsse
Size Codes and Installation / Grössen-Codierungen und Montage PMAFIX Pro
Installation IP68/IP69K / Montage IP68/IP69K
Size Codes / Grössen-Codierungen
Table 1 Tabelle 1
PMA Conduit Codes PMA Rohr-Codierungen
Nominal Width Nennweite
metric sizes metrische Grössen
PMA CodePMA Code
10 12 012 16 217 20 723 25 329 32 936 40 648 50 8
Types of Connector for Female Thread Adapters Steckertypenbezeichnung zu Innengewindeadapter
Type Bezeichnung
PMA Code
WithO-RingGroove/O-Ringeinstich (MIL C 5015) G
Table 2 Tabelle 2
Thread Codes Gewinde-Codierungen
Thread metric metrisches Gewinde
PMA CodePMA Code
M12x1.5 M12M16x1.5 M16M20x1.5 M20M25x1.5 M25M32x1.5 M32M40x1.5 M40M50x1.5 M50M63x1.5 M63
Thread UNEF Gewinde UNEF
PMA CodePMA Code
7⁄8 -20 UNEF U211-20 UNEF U241 3⁄16 -18 UNEF U291 7⁄16 -18 UNEF U351 ¾ -18 UNS U432 -18 UNS U502¼ -16 UN U56
A Corrugated conduitB Sealing and locking elementC Fitting bodyD Thread seal (O-ring or fl at gasket*)
A WellrohrB Dicht- und Verriege- lungselementC FittingkörperD Gewindedichtung (O-Ring od. Flachdichtung*)
To disengage the locking mechanism introduce a size 1 screwdriver parallel to the conduit into the opening shown in the detail drawing.
Zum Entriegeln Schraubenzieher Gr. 1 parallel zum Rohr in den Öffnungsschlitz beim Rohraustritt stecken.
Pull the conduit and screwdriver out of the fi tting to-gether keeping the screwdriver parallel to the conduit.
Schraubenzieher und Rohr parallel und gleichzeitig aus der Verschraubung ziehen.
Place corrugated conduit (A) at a slight angle against the sealing element (B), then push right into the end.
Wellrohr (A) leicht schräg am Dichtelement (B) ansetzen, dann bis zum Anschlag einstossen.
Push the conduit and sealing element (A+B) together into the outer body of the fi tting (C). Water or a lubricating agent can help facilitate the push-in process.
Rohr mit Dichtelement (A+B) in den Fittingkörper (C) einstossen. Wasser oder Gleitmittel können helfen, die nötige Einstosskraft zu reduzieren.
AB
D
1A
B
2
A+B
C3
CLICK!4 5 6The locking mechanism engages when the sealing element is pushed in fully.
Der Verriegelungsmechanismus rastet ein, wenn das Dichtelement völlig eingestossen ist.
Ensure to follow O-ring manufacturers guidelines when using O-rings for sealing purposes. / Bei Verwendung eines O-Ringes zur Gewindeabdichtung ist auf eine fachgerechte Montage zu achten.
Connectors: Part Number Code / Anschlüsse: Nummernschlüssel
44 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KNH straight, metric, metal / gerade, metrisch, MetallFor applications with high technical requirements and in most demanding climatic conditions.
Für Anwendungen mit erhöhten technischen Anforderungen und unter anspruchsvollsten Witterungseinflüssen.
NKNH-M120-10 MKNH-M120-10 M12x1.5 10 12 10.0 45.0NKNH-M160-10 MKNH-M160-10 M16x1.5 10 12 10.0 45.0NKNH-M162-10 MKNH-M162-10 M16x1.5 12 16 10.0 50.5NKNH-M202-10 MKNH-M202-10 M20x1.5 12 16 10.0 50.5NKNH-M207-10 MKNH-M207-10 M20x1.5 17 20 10.0 56.0NKNH-M257-11 MKNH-M257-11 M25x1.5 17 20 11.0 57.0NKNH-M253-11 MKNH-M253-11 M25x1.5 23 25 11.0 59.5NKNH-M323-13 MKNH-M323-13 M32x1.5 23 25 13.0 61.5NKNH-M329-13 MKNH-M329-13 M32x1.5 29 32 13.0 67.0NKNH-M409-13 MKNH-M409-13 M40x1.5 29 32 13.0 68.5NKNH-M406-13 MKNH-M406-13 M40x1.5 36 40 13.0 74.0NKNH-M506-14 MKNH-M506-14 M50x1.5 36 40 14.0 75.0NKNH-M508-14 MKNH-M508-14 M50x1.5 48 50 14.0 81.0NKNH-M638-14 MKNH-M638-14 M63x1.5 48 50 14.0 81.0
Order No.black
Order No.grey
Threadmetric
Fits to conduit sizeNW metric
Thread length(g)
Overall length(A)
Bestell-Nr.schwarz
Bestell-Nr.grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewindelänge (g)
Gesamtlänge(A)
• Fitting:Speciallymodifiedpolyamide6 Thread:nickel-platedbrass, Sealing:crosslinkedpolyesterelastomer• IP68 amd P69K even in dynamic applications• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery: Fitting body with sealing element, thread seal
• Fitting:SpeziellmodifiziertesPolyamid6 Gewindestutzen:Messingvernickelt Dichtung:Polyester-Elastomervernetzt• IP68undIP69KauchbeidynamischenAnwendungen• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Lieferumfang:Verschraubungskörper mit Dichtelement, Gewindedichtung
Patent / Patentiert
Connectors / Anschlüsse
PMAFIX Pro Metric, Metal / Metrisch, Metall
Dimensions / Dimensionen in mm
45For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KNZ straight, strain relief, metric, metal gerade, Zugentlastung, metrisch, Metall
For applications with high technical requirements and in most demanding climatic conditions like railway vehicle construction for carriage connections and heavy machine construction.
Für Anwendungen mit erhöhten technischen Anforderungen und unteranspruchsvollstenWitterungseinflüssenwieimSchienenfahr-zeugbau für Waggonverbindungen und schweren Maschinenbau.
NKNZ-M120/P1 M12x1.5 10 12 4.0 – 6.5 5.0 53.5NKNZ-M120/P2 M12x1.5 10 12 5.0 – 8.0 5.0 53.5NKNZ-M120/P3 M12x1.5 10 12 6.5 – 9.5 5.0 53.5NKNZ-M160/P1 M16x1.5 10 12 4.0 – 6.5 6.0 54.5NKNZ-M160/P2 M16x1.5 10 12 5.0 – 8.0 6.0 54.5NKNZ-M160/P3 M16x1.5 10 12 6.5 – 9.5 6.0 54.5NKNZ-M202/P1 M20x1.5 12 16 4.0 – 6.5 6.5 60.5NKNZ-M202/P3 M20x1.5 12 16 6.5 – 9.5 6.5 60.5NKNZ-M202/P4 M20x1.5 12 16 7.0 – 10.5 6.5 60.5NKNZ-M207/P3 M20x1.5 17 20 6.5 – 9.5 6.5 66.0NKNZ-M207/P4 M20x1.5 17 20 7.0 – 10.5 6.5 66.0NKNZ-M207/P5 M20x1.5 17 20 9.0 – 13.0 6.5 66.0NKNZ-M257/P5 M25x1.5 17 20 9.0 – 13.0 7.5 67.5NKNZ-M257/P6 M25x1.5 17 20 11.5 – 15.5 7.5 67.5NKNZ-M253/P5 M25x1.5 23 25 9.0 – 13.0 7.5 75.0NKNZ-M253/P6 M25x1.5 23 25 11.5 – 15.5 7.5 75.0NKNZ-M323/P2 M32x1.5 23 25 9.0 – 13.0 8.0 76.0NKNZ-M323/P4 M32x1.5 23 25 14.0 – 18.0 8.0 76.0NKNZ-M323/P5 M32x1.5 23 25 17.0 – 20.5 8.0 76.0NKNZ-M329/P2 M32x1.5 29 32 14.0 – 18.0 8.0 83.0NKNZ-M409/P4 M40x1.5 29 32 20.0 – 25.0 8.0 83.0NKNZ-M409/P5 M40x1.5 29 32 24.0 – 28.0 8.0 83.0NKNZ-M406/P2 M40x1.5 36 40 27.0 – 32.0 10.0 90.0NKNZ-M506/P1 M50x1.5 36 40 27.0 – 32.0 10.0 90.0NKNZ-M506/P3 M50x1.5 36 40 32.0 – 36.0 10.0 90.0NKNZ-M508/P2 M50x1.5 48 50 32.0 – 36.0 10.0 100.0NKNZ-M508/P3 M50x1.5 48 50 36.0 – 40.0 10.0 100.0NKNZ-M638/P1 M63x1.5 48 50 35.0 – 40.0 10.0 100.0NKNZ-M638/P2 M63x1.5 48 50 39.0 – 44.0 10.0 100.0
NKNZ-M207/P3-L M20x1.5 17 20 6.5 – 9.5 15.0 75.0NKNZ-M257/P5-L M25x1.5 17 20 9.0 – 13.0 15.0 75.0NKNZ-M257/P6-L M25x1.5 17 20 11.5 – 15.5 15.0 75.0NKNZ-M323/P2-L M32x1.5 23 25 9.0 – 13.0 15.0 83.0NKNZ-M323/P4-L M32x1.5 23 25 14.0 – 18.0 15.0 83.0NKNZ-M409/P4-L M40x1.5 29 32 20.0 – 25.0 15.0 90.0
Order No.black
Threadmetric
Fits to conduit sizeNW metric
Terminalrange
Thread length(g)
Overall length(A)
Bestell-Nr.schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Klemm-bereich
Gewindelänge (g)
Gesamtlänge(A)
Order No.black
Threadmetric
Fits to conduit sizeNW metric
Terminalrange
Thread length(g)
Overall length(A)
Bestell-Nr.schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Klemm-bereich
Gewindelänge (g)
Gesamtlänge(A)
Patent / Patentiert
•Fitting:Speciallymodifiedpolyamide6 Thread:nickel-platedbrass Sealing:crosslinkedpolyesterelastomer+Pflitschsealinginsert•IP68amdP69K even in dynamic applications•DuetotheintegratedPflitschinsert,cablesareheldandatthesame time sealed up to IP68 (10 bar).•Self-extinguishing•Freefromhalogensandcadmium•Excellentimpactstrength•Temperaturerange:–50°Cto+105°C;Short-term:+160°C•Temperaturerangesealinginsert:–40 °C to +135 °C•Contentofdelivery: Fitting body with sealing element, thread seal
•Fitting:SpeziellmodifiziertesPolyamid6 Gewindestutzen:Messingvernickelt Dichtung:Polyester-Elastomervernetzt+PflitschDichteinsatz•IP68undIP69KauchbeidynamischenAnwendungen•DankintegriertemPflitsch-EinsatzwerdendieKabelgehaltenund gleichzeitigoptimalbisIP68(10bar)abgedichtet.•Selbstverlöschend•Halogen-undcadmiumfrei•HervorragendeSchlagfestigkeit•Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Temperaturbereich Dichteinsatz Pflitsch: –40 °C bis +135 °C •Lieferumfang:VerschraubungskörpermitDichtelement,Gewindedichtung
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX Pro
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
46 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KAH 45° elbow, metric, metal / 45° Winkel, metrisch, MetallFor applications with high technical requirements and in most demanding climatic conditions.
Für Anwendungen mit erhöhten technischen Anforderungen und unter anspruchsvollsten Witterungseinflüssen.
NKAH-M120-10 MKAH-M120-10 M12x1.5 10 12 10.0 55.5 x 43.0NKAH-M160-10 MKAH-M160-10 M16x1.5 10 12 10.0 55.5 x 45.0NKAH-M162-10 MKAH-M162-10 M16x1.5 12 16 10.0 62.5 x 50.0NKAH-M202-10 MKAH-M202-10 M20x1.5 12 16 10.0 62.5 x 52.0NKAH-M207-10 MKAH-M207-10 M20x1.5 17 20 10.0 71.0 x 59.5NKAH-M257-11 MKAH-M257-11 M25x1.5 17 20 11.0 72.0 x 62.5NKAH-M253-11 MKAH-M253-11 M25x1.5 23 25 11.0 80.0 x 68.0NKAH-M323-13 MKAH-M323-13 M32x1.5 23 25 13.0 82.0 x 72.0NKAH-M329-13 MKAH-M329-13 M32x1.5 29 32 13.0 93.0 x 79.5NKAH-M409-13 MKAH-M409-13 M40x1.5 29 32 13.0 94.5 x 85.5NKAH-M406-13 MKAH-M406-13 M40x1.5 36 40 13.0 105.5 x 93.5NKAH-M506-14 MKAH-M506-14 M50x1.5 36 40 14.0 106.5 x 98.5NKAH-M508-14 MKAH-M508-14 M50x1.5 48 50 14.0 120.0 x 111.0NKAH-M638-14 MKAH-M638-14 M63x1.5 48 50 14.0 120.0 x 114.0
Order No.black
Order No.grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
External Dimension(A + B)
Bestell-Nr.schwarz
Bestell-Nr.grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Aussenmasse(A + B)
• Fitting:Speciallymodifiedpolyamide6 Thread:nickel-platedbrass Sealing:crosslinkedpolyesterelastomer• IP68 amd P69K even in dynamic applications• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery: Fitting body with sealing element, thread seal
• Fitting:SpeziellmodifiziertesPolyamid6 Gewindestutzen:Messingvernickelt Dichtung:Polyester-Elastomervernetzt• IP68undIP69KauchbeidynamischenAnwendungen• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Lieferumfang:Verschraubungskörper mit Dichtelement, Gewindedichtung
Patent / Patentiert
Connectors / Anschlüsse
PMAFIX Pro Metric, Metal / Metrisch, Metall
Dimensions / Dimensionen in mm
47For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KBH 90° elbow, metric, metal / 90° Winkel, metrisch, MetallFor applications with high technical requirements and in most demanding climatic conditions.
Für Anwendungen mit erhöhten technischen Anforderungen und unter anspruchsvollsten Witterungseinflüssen.
NKBH-M120-10 MKBH-M120-10 M12x1.5 10 12 10.0 44.0 x 62.5NKBH-M160-10 MKBH-M160-10 M16x1.5 10 12 10.0 44.0 x 64.5NKBH-M162-10 MKBH-M162-10 M16x1.5 12 16 10.0 47.5 x 72.0NKBH-M202-10 MKBH-M202-10 M20x1.5 12 16 10.0 47.5 x 74.0NKBH-M207-10 MKBH-M207-10 M20x1.5 17 20 10.0 53.0 x 81.0NKBH-M257-11 MKBH-M257-11 M25x1 .5 17 20 11.0 54.0 x 84.0NKBH-M253-11 MKBH-M253-11 M25x1.5 23 25 11.0 63.0 x 92.0NKBH-M323-13 MKBH-M323-13 M32x1.5 23 25 13.0 65.0 x 96.0NKBH-M329-13 MKBH-M329-13 M32x1.5 29 32 13.0 75.0 x 108.0NKBH-M409-13 MKBH-M409-13 M40x1.5 29 32 13.0 76.5 x 114.0NKBH-M406-13 MKBH-M406-13 M40x1.5 36 40 13.0 87.5 x 126.0NKBH-M506-14 MKBH-M506-14 M50x1.5 36 40 14.0 88.5 x 131.0NKBH-M508-14 MKBH-M508-14 M50x1.5 48 50 14.0 101.0 x 145.5NKBH-M638-14 MKBH-M638-14 M63x1.5 48 50 14.0 101.0 x 148.5
Order No.black
Order No.grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
External Dimension(A + B)
Bestell-Nr.schwarz
Bestell-Nr.grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Aussenmasse(A + B)
Patent / Patentiert
• Fitting:Speciallymodifiedpolyamide6 Thread:nickel-platedbrass Sealing:crosslinkedpolyesterelastomer• IP68 amd P69K even in dynamic applications• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery: Fitting body with sealing element, thread seal
• Fitting:SpeziellmodifiziertesPolyamid6 Gewindestutzen:Messingvernickelt Dichtung:Polyester-Elastomervernetzt• IP68undIP69KauchbeidynamischenAnwendungen• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Lieferumfang:Verschraubungskörper mit Dichtelement, Gewindedichtung
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX Pro
Dimensions / Dimensionen in mm
48 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KIHG Female thread adapter / Innengewindeadapter (UNEF)
KIS Female thread adapter, metal / Innengewindeadapter, Metall
For applications with high technical requirements and in most demandingclimaticconditions.TheUNEFfemalethreadfittingsaredesigned for assembly with round multi-pin connectors according to MIL-C5015 or matching back-shells.
Für Anwendungen mit erhöhten technischen Anforderungen und unter anspruchsvollsten Witterungseinflüssen. Die Verschraubungen eignen sich zum Anschluss an Rundstecker bzw. Rundstecker-Adapter nach MIL-C5015.
For applications with high technical requirements and in most demanding climatic conditions.
Für Anwendungen mit erhöhten technischen Anforderungen und unter anspruchsvollsten Witterungseinflüssen.
BKIHG-U212 7⁄8“-20 16 12 16 9.0 47.0BKIHG-U217 7⁄8“-20 16 17 20 9.0 52.5BKIHG-U242 1“-20 18 12 16 9.0 47.0BKIHG-U247 1“-20 18 17 20 9.0 52.5BKIHG-U243 1“-20 18 23 23 9.0 55.5BKIHG-U292 1 3⁄16“-18 20 12 16 9.0 50.5BKIHG-U297 1 3⁄166“-18 20 17 20 9.0 52.5BKIHG-U293 1 3⁄16“-18 20 23 25 9.0 55.5BKIHG-U299 1 3⁄16“-18 20 29 32 9.0 61.0 BKIHG-U357 1 7⁄16“-18 24 17 20 9.0 58.0BKIHG-U353 1 7⁄16“-18 24 23 25 9.0 55.5BKIHG-U359 1 7⁄16“-18 24 29 32 9.0 61.0BKIHG-U433 1 3⁄4“-18UNS 32 23 25 10.0 62.5BKIHG-U439 1 3⁄4“-18UNS 32 29 32 10.0 62.0BKIHG-U503 2“-18UNS 36 23 25 10.0 67.0BKIHG-U509 2“-18UNS 36 29 32 10.0 67.5BKIHG-U506 2“-18UNS 36 36 40 10.0 67.0BKIHG-U508 2“-18UNS 36 48 50 10.0 73.5BKIHG-U566 2 1⁄4“-16UNS 40 36 40 10.0 72.0BKIHG-U568 2 1⁄4“-16UNS 40 48 50 10.0 73.5
NKIS-M162 M16x1.5 12 16 9.0 49.0 NKIS-M207 M20x1.5 17 20 10.5 56.0 NKIS-M253 M25x1.5 23 25 10.5 58.5 NKIS-M329 M32x1.5 29 32 11.0 65.5 NKIS-M406 M40x1.5 36 40 13.5 72.0 NKIS-M508 M50x1.5 48 50 15.0 83.0 NKIS-M638 M63x1.5 48 50 17.5 84.0
Order No.black
ThreadUNEF
Shell sizeMIL
Fits to conduit sizeNW metric
Threadlength (g)
External Dimension(A + B)
Bestell-Nr.schwarz
GewindeUNEF
Steckergr.MIL
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Aussenmasse(A + B)
Order No.black
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
External Dimension(A + B)
Bestell-Nr.schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Aussenmasse(A + B)
• Fitting:Speciallymodifiedpolyamide6 Sealing:crosslinkedpolyesterelastomer• IP68 amd P69K even in dynamic applications• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery: Fitting body with sealing element, O-ring
• Fitting:SpeziellmodifiziertesPolyamid6 Dichtung:Polyester-Elastomervernetzt• IP68undIP69KauchbeidynamischenAnwendungen• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Lieferumfang:Verschraubungskörper mit Dichtelement, O-Ring
• Fitting:Speciallymodifiedpolyamide6 Femalethread:nickel-platedbrass Sealing:crosslinkedpolyesterelastomer• IP68 amd P69K on conduit side, even in dynamic applications• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery: Fitting body with sealing element
• Fitting:SpeziellmodifiziertesPolyamid6 Innengewinde:Messingvernickelt Dichtung:Polyester-Elastomervernetzt• IP68undIP69Krohrseitig,auchbeidynamischenAnwendungen• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C• Lieferumfang:Verschraubungskörper mit Dichtelement
Patent / Patentiert
Patent / Patentiert
Connectors / Anschlüsse
PMAFIX Pro Female Thread Adapters / Innengewindeadapter
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
49For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
KNH2 Sealing element / DichtelementThe Sealing elements are compatible with all PMA polyamide conduitsirrespectiveofprofile(coarseandfine)andwithallPMAFIXProtypesoffittingouterbodyofthecorresponding conduit dimension.
DieDichtelementesindkompatibelmitallenPMAPolyamid-RohrenundbeidenRohrprofilen(grobundfein)undinallePMAFIXProAussenkörper-BauformenderentsprechendenRohr-Grösseeinsetzbar.
KNH2-NW10 10 12 22.0 28.0KNH2-NW12 12 16 25.5 33.5 KNH2-NW17 17 20 31.5 38.5 KNH2-NW23 23 25 38.5 41.0 KNH2-NW29 29 32 46.5 46.5 KNH2-NW36 36 40 55.5 50.5 KNH2-NW48 48 50 68.0 56.5
Order No.black
Fits to conduit sizeNW metric
Diameter Overall length
Bestell-Nr.schwarz
Passend zu RohrgrösseNW metrisch
Durch-messer
Gesamt-länge
Patent / Patentiert
• Speciallymodifiedpolyamide6 sealing made from crosslinked polyester elastomer• Self-extinguishing• Freefromhalogensandcadmium• Temperaturerange:–50°Cto+105°C;Short-term:+160°C
• SpeziellmodifiziertesPolyamid6 DichtungausPolyester-Elastomervernetzt• Selbstverlöschend• Halogen-undcadmiumfrei• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C
Connectors / Anschlüsse
Sealing Element / Dichtelement PMAFIX Pro
Dimensions / Dimensionen in mm
50
Connectors / Anschlüsse
PMAFIX Part Number Code / Nummernschlüssel
B V N D P 7 01 / – GT16
Modification code / Modifikationscode
Serie NBaureihe N
Serie WBaureihe W
Serie BBaureihe B
Serie ABaureihe A
Serie OBaureihe O
Serie IBaureihe I
Serie YBaureihe Y
Serie TBaureihe T
Serie VBaureihe V
Safety retaining clip type / Sicherheitssperren TypGT = Universal Safety Clip / Universal-Sicherheitssperre.. = Oval Clip /Oval-Sperre
Nominal width PMAFLEX (Table 1) / NennweitePMAFLEX(Tabelle1)
Size of Thread (Table 2) / Gewindegrössen (Tabelle 2)
Code of Thread / Gewinde-Codierungen: P = PG Thread / PanzergewindePG M = Metric Thread / Metrisches Gewinde F = Metric Fine Thread / Metrisches Feingewinde N = NPT Thread / NPT-Gewinde G = Gas Thread / Gasrohr-Gewinde U = UNEF Round Connector / UNEF-Rundsteckergewinde
Modes of ingress protection / Schutzarten: D = Self-sealingIP66/SelbstdichtendIP66 L = With Seal Cap IP67 on Conduit / MitDichtungskappeIP67rohrseitig R = With Seal Cap IP68 on Conduit / MitDichtungskappeIP68rohrseitig V = With Gasket reinforced IP68 / MitDichtungssatzverstärktIP68 Z = Add. combined sealing with strain relief IP50 / IP68 Zus.kombinierteAbdichtungmitZugentlastungIP50/IP68
PMAFIX series / PMAFIXBaureihen: N = straight / gerade W = 90° elbow / 90° Winkel B = 90° curved elbow / 90° Bogenwinkel A = 45° elbow / 45° Winkel O= 90°elbowwithflange/ 90° Winkel mit Flansch
I = With Female Thread / Mit Innengewinde Y = Y Piece / Y-Stück T = T Piece / T-Stück V = V Piece / V-Stück
PMAFIX type / PMAFIXModell: V = Reinforced / Verstärkt S = Series V with swiveling coupler / Baureihe V drehbar E =Excertified/Exzertifiziert
Colours / Farben: B = black / schwarz M = grey with metal thread / grau mit Metallgewinde S = grey / grau A = black – anthracite / schwarz – anthrazit N = black with metal thread / T = transparent / transparent schwarz mit Metallgewinde X = special colour / Spezialfarbe
Connector SeriesAnschlussarmaturen-Baureihen
Connectors: Part Number Code / Anschlüsse: Nummernschlüssel
51
Connectors / Anschlüsse
Size Codes / Grössen-Codierungen PMAFIX
Size Codes / Grössen-Codierungen
Table 1 Tabelle 1
PMA Conduit Codes PMA Wellrohr-Codierungen
Nominal Width Nennweite
metric sizes metrische Grössen
PMA CodePMA Code
7 10 M10 12 012 16 217 20 723 25 329 32 936 40 648 50 8
Table 2 Tabelle 2
Thread Codes Gewinde-Codierungen
Thread metric Gewinde metrisch
PMA Code
Thread PG Gewinde PG
PMACode
Thread GasGewinde Gas
PMACode
Thread NPT Gewinde NPT
PMACode
Thread UNEF Gewinde UNEF
PMACode
M12x1.5 M12 PG07 P07 G¼ G00 3⁄8 -28 UNEF U09M16x1.5 M16 PG09 P09 G3⁄8 G01 7⁄16 -28 UNEF U10M20x1.5 M20 PG11 P11 G½ G02 N½ N02 1⁄2 -28 UNEF U12
PG13.5 P13 G¾ G04 N ¾ N04 9⁄16 -24 UNEF U13M25x1.5 M25 PG16 P16 G1 G06 N 1 N06 5⁄8 - 24 UNEF U15M32x1.5 M32 PG21 P21 G1¼ G07 N 1¼ N07 11⁄16 -24 UNEF U16M40x1.5 M40 PG29 P29 G1½ G08 N1½ N08 3⁄4 -20 UNEF U18M50x1.5 M50 PG36 P36 G2 G09 N 2 N09 13⁄16 -20 UNEF U20M63x1.5 M63 PG42 P42 G2¼ G10 7⁄8 -20 UNEF U21
PG48 P48 G2½ G11 15⁄16 -20 UNEF U231-20 UNEF U24
M 8x1.0 F08 1 1⁄16 -18 UNEF U26M12x1.0 F12 1 3⁄16 -18 UNEF U29M18x1.0 F18 1¼ -18 UNEF U30M30x1.5 F30 1 5⁄16 -18 UNEF U32
13⁄8-18 UNEF U341 7⁄16 -18 UNEF U3515⁄8 -18 UNEF U401 11⁄16 -20 UN U411 ¾ -18 UNS U432 -18 UNS U502¼ -16 UN U5623⁄8 -12 UN U572½ -12 UN U62
Types of Connector for Female Thread Adapters Steckertypenbezeichnung zu Innengewindeadapter
Typ Bezeichnung
PMA Code
AMP A Souriau (ex Burndy) BWithO-RingGroove/ O-Ringeinstich (MIL C 5015)
G
The designation PMAFIX describes a very large range of connec-tors for PMA conduits with the paten ted PMA safety clip system. Connectors are available for ingress protection IP66 and IP68. IP66 connectors are fitted with a pre- installed universal safety clip which ensu res a quick “push-in” installation. IP68 connectors for increased requirements will be delivered with a special conduit seal cap. The new PMAFIX IP68GT fittings combine simplestpush-in assembly with highest sealing performance.
Der Begriff PMAFIX bezeichnet ein riesiges Sorti ment an Anschlussarmaturen mit dem paten tier ten PMA-Sicher heits-Sperren sys tem für PMA Ka bel schutz-Wellrohre. Die Armaturen sind erhältlich für die Schutz arten IP66 und IP68. IP66-Armaturen sind mit einer vormon tierten Schnellmontagesperre aus ge rüstet, die eine einfache Einstossmontage erlauben. IP68-Armaturen für erhöhte Anforde rungen werden mit einer speziellen Rohr- dichtkap pe geliefert. Die neuen IP68GT-Armaturen vereinen die einfache Einstossmontage mit der erhöhten Dichtheit.
Connectors Anschlüsse
52
Connectors / Anschlüsse
PMAFIX Safety and Sealing Systems / Sicherheits- und Dichtsysteme
• Onepiecefitting• Conicalsealingmethod• Easy“push-in”installation• Pre-installedsafetyclipAFN2• Fitsanytypeofconduitprofile(TandG)• Excellentpull-outstrength• Re-openingforsafetyreasonsonly possible with a screwdriver
• EinteiligeAnschlussarmatur• AbdichtungdurchKonus• ProblemloseEinstossmontage• VormontierteSicherheitssperreAFN2• VerwendbarfürRohremit Fein- und Grobprofil (T und G)• AusgezeichneteAusreissfestigkeit• ÖffnungzurSicherheitnurmitdem Schraubenzieher möglich
• Highsealingthroughadditionalsealcap• Forhighestdynamicapplications• Fitsanytypeofconduitprofile(TandG)• Excellentpull-outstrength• Re-openingforsafetyreasonsonly possible with a screwdriver• AdditionalwaterprotectionringWPS for IP69K ingress protection in conjunction with the IP68 system to be applied right after the IP68 connector onto the conduit
• HoheDichtheitdurchzusätzliche Rohrdichtung• Fürhöchstedynamische Bean spruchungen• VerwendbarfürRohremit Fein- und Grobprofil (T und G)• AusgezeichneteAusreissfestigkeit• ÖffnungzurSicherheitnurmitdem Schraubenzieher• ZusätzlicherWasserprallschutzWPSfür IP69K Dichtheit bei 100 bar in Verbindung mit dem IP68 Dichtsystem, Anwendung unmittelbar nach der IP68 Armatur auf das Well rohr
• ThesinglepiecePMAFIXIP68GTfitting with integrated sealing cap and pre-installed locking clip• Simplepush-inassembly(aswiththe proven PMAFIX IP66 system)• Theextralongsealingcapguarantees the highest level of ingress protection•Compatiblewithalltypes of PMA conduits• Identicalapprovalsasfor the PMAFIX IP68 system• ThecompletePMAFIXIP68product rangeisavailableasaGTsingle component version• Fastmodificationofspecification drawings through simple addition of ‚GT‘totheexistingordernumber (eg. BVNV-M257 →BVNV-M257GT)
• EinteiligePMAFIXIP68GT-Anschluss- armatur mit integrierter Dichtung und vormontierter Sperre.• EinfachsteEinstossmontage(wiebeim bewährten PMAFIX IP66-System)• ExtralangeintegrierteDichtung garantiert höchste Dichtheit• AllePMA-Rohrtypenmontierbar• IdentischeZulassungenwiebeim IP68-System• GesamtesPMAFIXIP68-Produkt- sortiment ist als einteilige GT-Version verfügbar• SchnelleAdaptionvonSpezifikationen durchErgänzungvon“GT“bei Bestellnummern (Bsp.BVNV-M257→ BVNV-M257GT)
IP68 static, IP67 dynamic / IP68 statisch, IP67 dynamischIP69K acc. to DIN40050 / IP69K nach DIN40050
IP66 static, IP54 dynamic / IP66 statisch, IP54 dynamisch
IP68 static, IP67 dynamic / IP68 statisch, IP67 dynamischIP69K acc. to DIN40050 / IP69K nach DIN40050
IP66
IP68
IP68GT
Patent / Patentiert
Patent / Patentiert
Patent / Patentiert
53
Connectors / Anschlüsse
Installation / Montage PMAFIX
Installation IP66 / Montage IP66
Installation IP68GT / Montage IP68GT
Installation IP68 (IP69K) / Montage IP68 (IP69K)
Locking clip pre-installed in all IP66 connectors / Sperre vormontiert in allen IP66 Anschlussarmaturen
Pre-installed sealing cap and locking clip in all IP68GT connectors Dichtung und Sperre vormontiert in allen IP68GT Anschlussarmaturen
* For safety reasons, oval clip will not fit if seal cap is not fully installed. / * Aus Sicherheitsgründen kann die Oval-Sperre nur montiert werden, wenn die Dichtkappe vollständig eingestossen ist.Ensure to follow O-ring manufacturers guidelines when using O-rings for sealing purposes. / Bei Verwendung eines O-Ringes zur Gewindeabdichtung ist auf eine fachgerechte Montage zu achten.
* Ensure to follow O-ring manufacturers guidelines when using O-rings for sealing purposes. / Bei Verwendung eines O-Ringes zur Gewindeabdichtung ist auf eine fachgerechte Montage zu achten.
2
2
1
A A
A
A
BB
B
C
A
B
CD
1 3
A
B
C
D
EB
65
B
B
A
2 3
4
A D
C
1
3
C
2
2
1
A A
A
A
BB
B
C
A
B
CD
1 3
A
B
C
D
EB
65
B
B
A
2 3
4
A D
C
1
3
C
2
2
1
A A
A
A
BB
B
C
A
B
CD
1 3
A
B
C
D
EB
65
B
B
A
2 3
4
A D
C
1
3
C
2
2
1
A A
A
A
BB
B
C
A
B
CD
1 3
A
B
C
D
EB
65
B
B
A
2 3
4
A D
C
1
3
C
A. ConduitB. FittingC. Universal safety clip
A. WellrohrB. AnschlussarmaturC. Universal Sicherheitssperre
A. ConduitB. Fitting with integrated sealing capC. Universal safety clipD. Thread seal (either O-ring or flat gasket*, not both)
A. WellrohrB. Anschlussarmatur mit eingelegter DichtkappeC. Universal SicherheitssperreD. Dichtung (entweder O-Ring oder Flachdichtung*, nicht beide)
A. ConduitB. Sealing capC. FittingD. Oval clipE. Thread seal (O-ring or flat seal*)
A. WellrohrB. RohrdichtungC. AnschlussarmaturD. Oval-SperreE. Dichtung (O-Ring oder Flachdichtung*)
For IP69K:Based on IP68 SystemA. Conduit with IP68 fittingB. WPS half shells
Für IP69K:Basis IP68-SystemA. Wellrohr mit IP68-VerschraubungB. WPS-Ringhälften
Push in the conduit (A) with a slight twist until the stop.
Wellrohr (A) mit leichter Drehbewegung bis zum Anschlag der Anschluss-armatur einstossen.
Push in the conduit (A) right into the end of the fitting (B) with a slight twist. Additional insertion resistance will be felt when the end of the fitting has been reached.
Wellrohr (A) mit leichter Drehbewegung bis zum Anschlag der Anschlussarmatur (B) einstossen. Ein zusätzlicher Widerstand wird bei korrekter Monage spürbar.
Push sealing cap (B) completely onto the conduit in order to achieve IP68.
Für Schutzart IP68 Rohrdichtung (B) ganz auf das Rohr aufstossen.
To re-open use a screwdriver.
Wieder öffnen mittels Schraubenzieher
To re-open use a screwdriver. The screwdriver slot in the oval clip (C) should be on the conduit side.
Wieder öffnen mittels Schraubenzieher. Die Schraubenzieher-Öffnungsnut an der Sperre (C) muss rohrseitig positioniert sein.
To re-open use a screwdriver. The screwdriver slot in the oval clip (C) should be on the conduit side.
Wieder öffnen mittels Schraubenzieher. Die Schraubenzieher-Öffnungsnut an der Sperre (C) muss rohrseitig positioniert sein.
Push in the conduit (A) with a slight twist until the stop. Insert oval clip (D) in the locking element window and click into place. Screwdriver slot in the oval clip should be on conduit side.
Wellrohr mit leichter Drehbewegung bis zum Anschlag in Armatur einstossen. Oval-Sperre (D) in das Sperrenfenster einsetzen und einrasten. Öffnungsnut muss rohrseitig positioniert sein.
To re-open use a screwdriver.
Wieder öffnen mittels Schraubenzieher.
54 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Metric, Polyamide / Metrisch, Polyamid
VN straight, metric / gerade, metrisch•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VND-M12MGT *VNV-M12M M12x1.5 7 10 11.0 34.5 *VND-M120GT *VNV-M120 M12x1.5 10 12 11.0 36.5 *VND-M160GT *VNV-M160 M16x1.5 10 12 11.0 36.5 *VND-M162GT *VNV-M162 M16x1.5 12 16 11.0 39.5 *VND-M200GT *VNV-M200 M20x1.5 10 12 11.0 36.5 *VND-M202GT *VNV-M202 M20x1.5 12 16 11.0 39.5 *VND-M207GT *VNV-M207 M20x1.5 17 20 11.0 47.5 *VND-M203GT *VNV-M203 M20x1.5 23 25 11.0 51.0 *VND-M257GT *VNV-M257 M25x1.5 17 20 12.0 48.5 *VND-M253GT *VNV-M253 M25x1.5 23 25 12.0 52.0 *VND-M323GT *VNV-M323 M32x1.5 23 25 15.0 55.5 *VND-M329GT *VNV-M329 M32x1.5 29 32 15.0 56.0 *VND-M409GT *VNV-M409 M40x1.5 29 32 19.0 60.0 *VND-M406GT *VNV-M406 M40x1.5 36 40 19.0 72.5 *VND-M506GT *VNV-M506 M50x1.5 36 40 19.0 72.0 *VND-M508GT *VNV-M508 M50x1.5 48 50 19.0 72.5 *VND-M638GT *VNV-M638 M63x1.5 48 50 19.0 72.0
Order No.IP66
Order No.IP68
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66
Bestell-Nr.IP68
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Canbeeasilyre-openedwithascrewdriver• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• EinfacheWiederöffnungmitSchraubenzieher• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
g = Thread length / Gewindelänge A = Overalllength/Gesamtlänge
g = Thread length / Gewindelänge A x B = Externaldimensions/Aussenmasse
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
55For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Polyamide / Metrisch, Polyamid PMAFIX
VNZ straight, metric, strain relief / gerade, metrisch, Zugentlastung
VA 45° elbow, metric / 45° Winkel, metrisch
•Forcableprotectionsystemsinawiderangeofapplications•Forseparationofdampanddryareas
•FürKabelschutzineinembreitenAnwendungsgebiet•ZurTrennungvonNass-undTrockenräumen
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VNDZ-M160GT – M16x1.5 10 12 5.0 – 10.0 8.0 62.0 *VNDZ-M162GT *VNZ-M162S M16x1.5 12 16 5.0 – 10.0 8.0 62.0*VNDZ-M207GT *VNZ-M207S M20x1.5 17 20 10.0 – 14.0 8.0 72.0*VNDZ-M253GT *VNZ-M253S M25x1.5 23 25 13.0 – 18.0 8.0 81.0*VNDZ-M329GT *VNZ-M329S M32x1.5 29 32 18.0 – 25.0 10.0 85.0*VNDZ-M406GT *VNZ-M406S M40x1.5 36 40 22.0 – 32.0 10.0 108.5*VNDZ-M508GT *VNZ-M508S M50x1.5 48 50 30.0 – 38.0 12.0 119.5*VNDZ-M638GT *VNZ-M638S M63x1.5 48 50 34.0 – 44.0 12.0 119.5
*VAD-M120GT – M12x1.5 10 12 11.0 43.5 x 37.0 *VAD-M160GT *VAV-M160 M16x1.5 10 12 11.0 43.5 x 38.0 *VAD-M162GT *VAV-M162 M16x1.5 12 16 11.0 48.0 x 40.0 *VAD-M202GT *VAV-M202 M20x1.5 12 16 11.0 48.0 x 41.5 *VAD-M207GT *VAV-M207 M20x1.5 17 20 11.0 55.5 x 51.5 *VAD-M253GT *VAV-M253 M25x1.5 23 25 12.0 65.0 x 58.5 *VAD-M329GT *VAV-M329 M32x1.5 29 32 15.0 73.5 x 66.5 *VAD-M406GT *VAV-M406 M40x1.5 36 40 19.0 92.5 x 85.5 *VAD-M506GT *VAV-M506 M50x1.5 36 40 19.0 92.5 x 89.5 *VAD-M508GT *VAV-M508 M50x1.5 48 50 19.0 100.0 x 96.0 *VAD-M638GT *VAV-M638 M63x1.5 48 50 19.0 100.0 x 104.0
Order No.IP66
Order No.IP68
Threadmetric
Fits to conduit sizeNW metric
Terminalrange
Threadlength
Overalllength
Bestell-Nr.IP66
Bestell-Nr.IP68
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Klemm-bereich
Gewinde- länge
Gesamt-länge
Order No.IP66
Order No.IP68
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Externaldimensions
Bestell-Nr.IP66
Bestell-Nr.IP68
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-gradeformulatedpolyamide6,veryhighimpactresistance• Easyinstallation:simplepushtheconduitin• Highconduitpull-outstrength• Integratedstrainreliefoptimallyholdsandsealscables• Ifseveralconductorsareusedwiththeconnectormultiplesealing inserts should be considered• Verygoodchemicalproperties,freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2), strain relief insert IP68GT: Fittingwithpre-assembleduniversalclips(AFN2)andconduit seal (NVN3-GT); strain relief insert and thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),strainreliefinsert,conduitand thread seal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• EinfachsteMontage:Rohreinschieben,hoheWellrohr-Ausreisskräfte• MitintegrierterZugentlastungwerdendieKabelgehaltenundoptimal abgedichtet• WerdenmehrereLeiterdurchdieVerschraubunggeführtsind Mehrfachdichteinsätze zu verwenden• SehrgutechemischeEigenschaften,halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontierterUniversal-Sicherheitssperre(AFN2) undRohrdichtung(NVN3-GT);Zugentlastungs-Einsatzund Gewindedichtung IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-gradespeciallyformulatedpolyamide6• Extremelyhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easyinstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseals (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
IP68GT available. Please replace “S” at the end with “GT” (for example BVNZ-M207GT). (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”amEndedurch“GT”ersetzen(z.B.BVNZ-M207GT).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Note:MDEmultiplesealinginsertsareavailableforthisproduct.Hinweis: MDEMehrfachdichteinsätzesindfürdiesesProdukterhältlich.
56 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Metric, Polyamide / Metrisch, Polyamid
VW 90° elbow, metric / 90° Winkel, metrisch
VB 90° curved elbow, metric / 90° Bogenwinkel, metrisch
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VWD-M12MGT *VWV-M12M M12x1.5 7 10 11.0 32.0 x 35.0*VWD-M120GT *VWV-M120 M12x1.5 10 12 11.0 34.0 x 39.5*VWD-M160GT *VWV-M160 M16x1.5 10 12 11.0 34.0 x 40.5 *VWD-M162GT *VWV-M162 M16x1.5 12 16 11.0 38.5 x 46.0*VWD-M200GT – M20x1.5 10 12 11.0 34.0 x 42.5 *VWD-M202GT *VWV-M202 M20x1.5 12 16 11.0 38.5 x 47.5 *VWD-M207GT *VWV-M207 M20x1.5 17 20 11.0 43.5 x 58.5 *VWD-M253GT *VWV-M253 M25x1.5 23 25 12.0 54.0 x 65.0 *VWD-M329GT *VWV-M329 M32x1.5 29 32 15.0 64.5 x 73.0 *VWD-M406GT *VWV-M406 M40x1.5 36 40 19.0 78.0 x 96.0 *VWD-M508GT *VWV-M508 M50x1.5 48 50 19.0 91.5 x 106.0
*VBD-M207GT *VBV-M207 M20x1.5 17 20 11.0 47.5 x 73.0 *VBD-M257GT *VBV-M257 M25x1.5 17 20 12.0 48.5 x 76.0 *VBD-M253GT *VBV-M253 M25x1.5 23 25 12.0 57.5 x 83.0 *VBD-M323GT *VBV-M323 M32x1.5 23 25 15.0 61.0 x 87.5 *VBD-M329GT *VBV-M329 M32x1.5 29 32 15.0 70.5 x 93.0 *VBD-M409GT *VBV-M409 M40x1.5 29 32 19.0 74.5 x 98.5 *VBD-M406GT *VBV-M406 M40x1.5 36 40 19.0 85.0 x 121.0 *VBD-M506GT *VBV-M506 M50x1.5 36 40 19.0 85.0 x 125.0 *VBD-M508GT *VBV-M508 M50x1.5 48 50 19.0 98.5 x 130.0 *VBD-M638GT *VBV-M638 M63x1.5 48 50 19.0 98.5 x 138.0
Order No.IP66
Order No.IP68
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Externaldimensions
Bestell-Nr.IP66
Bestell-Nr.IP68
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen- masse
Order No.IP66
Order No.IP68
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Exernal dimensions
Bestell-Nr.IP66
Bestell-Nr.IP68
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-gradespeciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easyinstallation:simplypushtheconduitin• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-gradespeciallyformulatedpolyamide6• Easyinstallation• Highconduitpull-outstrength• Easythreadingofwiresandcables• Self-extinguishing• Freefromhalogensandphosphor• Excellentimpactstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• EinfacheMontage• HoheWellrohr-Ausreisskräfte• ProblemlosesEinziehenderEinzeladernoderKabel• Selbstverlöschend• Halogen-undphosphorfrei• HervorragendeSchlagfestigkeit• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
For smaller conduit sizes NW 07 to NW 12 appropriate standard elbows of type VW are also available.FürkleinereNennweitenNW07bisNW12sindauchStandardwinkeldesTypsVWerhältlich.
For the sizes NW 17 to NW 48 curved elbows of type VB are also available.FürdieGrössenNW17bisNW48sindauchBogenwinkeldesTypsVBerhältlich.
57For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX
VN straight, metric, metal / gerade, metrisch, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVNV-M120-10 MVNV-M120-10 M12x1.5 10 12 10.0 40.0 NVNV-M120-5 MVNV-M120-5 M12x1.5 10 12 5.0 35.0 NVNV-M160-10 MVNV-M160-10 M16x1.5 10 12 10.0 40.0 NVNV-M160-5 MVNV-M160-5 M16x1.5 10 12 5.0 35.0 NVNV-M162-10 MVNV-M162-10 M16x1.5 12 16 10.0 43.0 NVNV-M162-5 MVNV-M162-5 M16x1.5 12 16 5.0 38.0 NVNV-M202-10 MVNV-M202-10 M20x1.5 12 16 10.0 43.0 NVNV-M202-6 MVNV-M202-6 M20x1.5 12 16 6.0 39.0 NVNV-M207-10 MVNV-M207-10 M20x1.5 17 20 10.0 51.0 NVNV-M207-6 MVNV-M207-6 M20x1.5 17 20 6.0 47.0 NVNV-M257-11 MVNV-M257-11 M25x1.5 17 20 11.0 52.0 NVNV-M257-7 MVNV-M257-7 M25x1.5 17 20 7.0 48.0 NVNV-M253-11 MVNV-M253-11 M25x1.5 23 25 11.0 54.0 NVNV-M253-7 MVNV-M253-7 M25x1.5 23 25 7.0 50.0 NVNV-M323-13 MVNV-M323-13 M32x1.5 23 25 13.0 56.0 NVNV-M323-8 MVNV-M323-8 M32x1.5 23 25 8.0 51.0NVNV-M329-13 MVNV-M329-13 M32x1.5 29 32 13.0 57.3 NVNV-M329-8 MVNV-M329-8 M32x1.5 29 32 8.0 52.3 NVNV-M409-13 MVNV-M409-13 M40x1.5 29 32 13.0 57.3 NVNV-M409-8 MVNV-M409-8 M40x1.5 29 32 8.0 52.3 NVNV-M406-13 MVNV-M406-13 M40x1.5 36 40 13.0 71.4 NVNV-M406-8 MVNV-M406-8 M40x1.5 36 40 8.0 66.4 NVNV-M506-14 MVNV-M506-14 M50x1.5 36 40 14.0 72.4 NVNV-M506-9 MVNV-M506-9 M50x1.5 36 40 9.0 67.4 NVNV-M508-14 MVNV-M508-14 M50x1.5 48 50 14.0 72.4 NVNV-M508-9 MVNV-M508-9 M50x1.5 48 50 9.0 67.4 NVNV-M638-14 MVNV-M638-14 M63x1.5 48 50 14.0 72.4 NVNV-M638-10 MVNV-M638-10 M63x1.5 48 50 10.0 68.4
Order No.IP68, black
Order No.IP68, grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Overall length
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-gradespeciallyformulatedpolyamide6, thread made of nickel-plated brass• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Extremelyhighthreadandsystemconnectionstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4 or OR)
• Hochwertiges,speziellformuliertesPolyamid6, Gewindestutzen aus Messing vernickelt• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• ExtremhoheGewinde-undSystemverbindungsfestigkeit• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4oder O-Ring) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” prior to the thread length (for example NVNV-M120GT-10).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”vorderGewindelängeeinfügen(z.B.NVNV-M120GT-10).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
58 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Metric, Metal / Metrisch, Metall
VNZ straight, metric, strain relief, metal gerade, metrisch, Zugentlastung, Metall
•Inrailwayvehicleandheavymachineconstruction•Fortheseparationofdampanddryareas
•ImSchienenfahrzeugbauundschwerenMaschinenbau•ZurTrennungvonNass-undTrockenräumen
NVNZ-M120S/P1 NVNZ-M120R/P DE-M120/P1 M12x1.5 10 12 4.0 – 6.5 5.0 48.5 NVNZ-M120S/P2 DE-M120/P2 M12x1.5 10 12 5.0 – 8.0 5.0 48.5 NVNZ-M120S/P3 DE-M120/P3 M12x1.5 10 12 6.5 – 9.5 5.0 48.5 NVNZ-M160S/P1 NVNZ-M160R/P DE-M160/P1 M16x1.5 10 12 4.0 – 6.5 6.0 49.5 NVNZ-M160S/P2 DE-M160/P2 M16x1.5 10 12 5.0 – 8.0 6.0 49.5 NVNZ-M160S/P3 DE-M160/P3 M16x1.5 10 12 6.5 – 9.5 6.0 49.5 NVNZ-M202S/P1 NVNZ-M202R/P DE-M202/P1 M20x1.5 12 16 4.0 – 6.5 6.0 54.0 NVNZ-M202S/P3 DE-M202/P3 M20x1.5 12 16 6.5 – 9.5 6.0 54.0 NVNZ-M202S/P4 DE-M202/P4 M20x1.5 12 16 7.0 – 10.5 6.0 54.0 NVNZ-M207S/P3 NVNZ-M207R/P DE-M207/P3 M20x1.5 17 20 6.5 – 9.5 6.5 60.0NVNZ-M207S/P4 DE-M207/P4 M20x1.5 17 20 7.0 – 10.5 6.5 60.0 NVNZ-M207S/P5 DE-M207/P5 M20x1.5 17 20 9.0 – 13.0 6.5 60.0 NVNZ-M253S/P5 NVNZ-M253R/P DE-M253/P5 M25x1.5 23 25 9.0 – 13.0 7.5 72.5 NVNZ-M253S/P6 DE-M253/P6 M25x1.5 23 25 11.5 – 15.5 7.5 72.5 NVNZ-M257S/P4 NVNZ-M257R/P DE-M257/P4 M25x1.5 17 20 7.0 – 10.0 7.5 61.5 NVNZ-M257S/P5 DE-M257/P5 M25x1.5 17 20 9.0 – 13.0 7.5 61.5 NVNZ-M257S/P6 DE-M257/P6 M25x1.5 17 20 11.5 – 15.5 7.5 61.5 NVNZ-M323S/P4 NVNZ-M323R/P DE-M323/P4 M32x1.5 23 25 14.0 – 18.0 8.0 73.0 NVNZ-M323S/P5 NVNZ-M323R1/P DE-M323/P5 M32x1.5 23 25 17.0 – 20.5 8.0 73.0 NVNZ-M329S/P2 NVNZ-M329R/P DE-M329/P2 M32x1.5 29 32 14.0 – 18.0 8.0 73.0 NVNZ-M329S/P3 DE-M329/P3 M32x1.5 29 32 17.0 – 20.5 8.0 73.0 NVNZ-M329S/P4 DE-M329/P4 M32x1.5 29 32 20.0 – 25.0 8.0 73.0 NVNZ-M406S/P1 NVNZ-M406R/P DE-M406/P1 M40x1.5 36 40 20.0 – 25.0 9.0 87.0 NVNZ-M406S/P2 DE-M406/P2 M40x1.5 36 40 24.0 – 28.0 9.0 87.0 NVNZ-M409S/P1 NVNZ-M409R/P DE-M409/P1 M40x1.5 29 32 11.5 –15.5 8.0 73.0 NVNZ-M409S/P2 DE-M409/P2 M40x1.5 29 32 14.0 –18.0 8.0 73.0 NVNZ-M409S/P3 DE-M409/P3 M40x1.5 29 32 17.0 –20.5 8.0 73.0 NVNZ-M409S/P4 DE-M409/P4 M40x1.5 29 32 20.0 – 25.0 8.0 73.0 NVNZ-M409S/P5 DE-M409/P5 M40x1.5 29 32 24.0 – 28.0 8.0 73.0 NVNZ-M506S/P1 NVNZ-M506R/P DE-M506/P1 M50x1.5 36 40 27.0 – 32.0 9.0 89.5 NVNZ-M506S/P3 DE-M506/P3 M50x1.5 36 40 32.0 – 36.0 9.0 89.5 NVNZ-M508S/P2 NVNZ-M508R/P DE-M508/P2 M50x1.5 48 50 32.0 – 36.0 9.0 92.0 NVNZ-M508S/P3 DE-M508/P3 M50x1.5 48 50 36.0 – 40.0 9.0 92.0 NVNZ-M638S/P1 NVNZ-M638R/P DE-M638/P1 M63x1.5 48 50 35.0 – 40.0 10.0 90.5 NVNZ-M638S/P2 DE-M638/P2 M63x1.5 48 50 39.0 – 44.0 10.0 90.5
Order No.Compl., black
Order No.Fitting*
Order No.Insert
Threadmetric
Fits to conduit sizeNW metric
Terminalrange
Threadlength
Overalllength
Bestell-Nr.Kompl.,schwarz
Bestell-Nr.Verschraubung*
Bestell-Nr. Einsatz
Gewindemetrisch
Passend zu Rohrgr. NW metrisch
Klemm-bereich
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6,threadmadeofnickel-plate brass, sealing inserts are made from TPE-V• Veryhighimpactresistance• Withintegratedstrainreliefandoptimalingressprotectionatthecable (up to IP68 / 10 bar)• Highthreadandsystemconnectionstrength• Vibration-resistantconnectiontoPMAFLEXconduits• Easyassembly• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Excellentimpactstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• TemperaturerangesealinginsertPflitsch: –40 °C to +135 °C• Contentofdelivery: IP68GT: Complete: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); sealing insert, O-ring (OR) Fitting*: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); O-ring (OR) IP68: Complete: Fittingwithovalclips(OVN2),sealinginsert, conduit seal (NVN3), O-ring (OR) Fitting*: Fittingwithovalclips(OVN2),conduitseal(NVN3), O-ring (OR)•Forseveralconductorsmultiplesealinginsertsareavailable(MDE)
• Hochwertiges,speziellformuliertesPolyamid6,Gewindestutzenaus Messingvernickelt,DichteinsatzausTPE-V• HervorragendeSchlagfestigkeit• MitintegrierterZugentlastungundoptimalerAbdichtungüberdas Kabel(biszuIP6810bar)• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• TemperaturbereichDichteinsatzPflitsch:–40 °C bis +135 °C • Lieferumfang: IP68GT: Komplett: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Dichteinsatz, O-Ring(OR) Verschraubung*: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);O-Ring(OR) IP68: Komplett: ArmaturmitOval-Sperren(OVN2),Dichteinsatz, Rohrdichtung(NVN3),O-Ring(OR) Verschraubung*: ArmaturmitOval-Sperren(OVN2),Rohrdichtung (NVN3),O-Ring(OR)• FürmehrereLeitersindMehrfachdichteinsätzeerhältlich(MDE)
Dimensions / Dimensionen in mm
* = without insert / * = ohne Dichteinsatz
IP68GT available. Please replace “S” or “R” with “GT” (for example NVNZ-M120GT/P1, NVNZ-M120GT/P).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”oder“R”durch“GT”ersetzen(z.B.NVNZ-M120GT/P1,NVNZ-M120GT/P).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Note: –MDEmultiplesealinginsertsareavailableforthisproduct –R/PversionoffittinghastobeusedincombinationwithmultiplesealinginsertsHinweis: –MDEMehrfachdichteinsätzesindfürdiesesProdukterhältlich –FürMehrfachdichteinsätzeR/P-VersionderVerschraubungverwenden
59For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX
• High-grade,speciallyformulatedpolyamide6,threadmadeof nickel-plate brass, sealing inserts are made from TPE-V• Veryhighimpactresistance• Withintegratedstrainreliefandoptimalingressprotectionatthecable (up to IP68 / 10 bar)• Highthreadandsystemconnectionstrength• Vibration-resistantconnectiontoPMAFLEXconduits• Easyassembly• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Excellentimpactstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• TemperaturerangesealinginsertPflitsch: –40 °C to +135 °C• Contentofdelivery: IP68GT: Complete: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); sealing insert, O-ring (OR) Fitting*: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); O-ring (OR) IP68: Complete: Fittingwithovalclips(OVN2),sealinginsert, conduit seal (NVN3), O-ring (OR) Fitting*: Fittingwithovalclips(OVN2),conduitseal(NVN3), O-ring (OR)• Forseveralconductorsmultiplesealinginsertsareavailable(MDE)
• Hochwertiges,speziellformuliertesPolyamid6,Gewindestutzenaus Messingvernickelt,DichteinsatzausTPE-V• HervorragendeSchlagfestigkeit• MitintegrierterZugentlastungundoptimalerAbdichtungüberdas Kabel (bis zu IP68 10 bar)• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• TemperaturbereichDichteinsatzPflitsch:–40 °C bis +135 °C • Lieferumfang: IP68GT: Komplett: ArmaturmitvormontiertenUniversal-Sicherheits- sperren(AFN2)undRohrdichtung(NVN3-GT); Dichteinsatz,O-Ring(OR) Verschraubung*: ArmaturmitvormontiertenUniversal-Sicherheits- sperren(AFN2)undRohrdichtung(NVN3-GT); O-Ring(OR) IP68: Komplett: ArmaturmitOval-Sperren(OVN2),Dichteinsatz, Rohrdichtung(NVN3),O-Ring(OR) Verschraubung*: ArmaturmitOval-Sperren(OVN2),Rohrdichtung (NVN3),O-Ring(OR)• FürmehrereLeitersindMehrfachdichteinsätzeerhältlich(MDE)
VNZ straight, metric, strain relief, metal gerade, metrisch, Zugentlastung, Metall
•Inrailwayvehicleandheavymachineconstruction•Fortheseparationofdampanddryareas
•ImSchienenfahrzeugbauundschwerenMaschinenbau•ZurTrennungvonNass-undTrockenräumen
NVNZ-M120S/P1-L NVNZ-M120R/P-L DE-M120/P1 M12x1.5 10 12 4.0 – 6.5 15.0 66.5 NVNZ-M160S/P1-L NVNZ-M160R/P-L DE-M160/P1 M16x1.5 10 12 4.0 – 6.5 15.0 58.5 NVNZ-M160S/P2-L DE-M160/P2 M16x1.5 10 12 5.0 – 8.0 15.0 58.5 NVNZ-M160S/P3-L DE-M160/P3 M16x1.5 10 12 6.5 – 9.5 15.0 58.5 NVNZ-M202S/P1-L NVNZ-M202R/P-L DE-M202/P1 M20x1.5 12 16 4.0 – 6.5 15.0 62.5 NVNZ-M202S/P3-L DE-M202/P3 M20x1.5 12 16 6.5 – 9.5 15.0 62.5 NVNZ-M202S/P4-L DE-M202/P4 M20x1.5 12 16 7.0 – 10.5 15.0 62.5 NVNZ-M207S/P3-L NVNZ-M207R/P-L DE-M207/P3 M20x1.5 17 20 6.5 – 9.5 15.0 68.5 NVNZ-M207S/P4-L DE-M207/P4 M20x1.5 17 20 7.0 – 10.5 15.0 68.5 NVNZ-M207S/P5-L DE-M207/P5 M20x1.5 17 20 9.0 – 13.0 15.0 68.5 NVNZ-M257S/P5-L NVNZ-M257R/P-L DE-M257/P5 M25x1.5 17 20 9.0 – 13.0 15.0 69.0 NVNZ-M257S/P6-L DE-M257/P6 M25x1.5 17 20 11.5 – 15.5 15.0 69.0 NVNZ-M323S/P4-L NVNZ-M323R/P-L DE-M323/P4 M32x1.5 23 25 14.0 – 18.0 15.0 80.0 NVNZ-M323S/P5-L NVNZ-M323R1/P-L DE-M323/P5 M32x1.5 23 25 17.0 – 20.5 15.0 80.0 NVNZ-M329S/P2-L NVNZ-M329R/P-L DE-M329/P2 M32x1.5 29 32 14.0 – 18.0 15.0 91.0 NVNZ-M329S/P3-L DE-M329/P3 M32x1.5 29 32 17.0 – 20.5 15.0 91.0 NVNZ-M409S/P3-L NVNZ-M409R/P-L DE-M409/P3 M40x1.5 29 32 17.0 – 20.5 15.0 80.0 NVNZ-M409S/P4-L DE-M409/P4 M40x1.5 29 32 20.0 – 25.0 15.0 80.0 NVNZ-M409S/P5-L DE-M409/P5 M40x1.5 29 32 24.0 – 28.0 15.0 80.0 NVNZ-M506S/P1-L NVNZ-M506R/P-L DE-M506/P1 M50x1.5 36 40 27.0 – 32.0 15.0 94.5 NVNZ-M506S/P3-L DE-M506/P3 M50x1.5 36 40 32.0 – 36.0 15.0 94.5 NVNZ-M508S/P2-L NVNZ-M508R/P-L DE-M508/P2 M50x1.5 48 50 32.0 – 36.0 15.0 97.0 NVNZ-M508S/P3-L DE-M508/P3 M50x1.5 48 50 36.0 – 40.0 15.0 97.0 NVNZ-M638S/P1-L NVNZ-M638R/P-L DE-M638/P1 M63x1.5 48 50 35.0 – 40.0 15.0 95.5 NVNZ-M638S/P2-L DE-M638/P2 M63x1.5 48 50 39.0 – 44.0 15.0 95.5
Order No.Compl., black
Order No.Fitting*
Order No.Insert
Threadmetric
Fits to cond. sizeNW metric
Terminalrange
Threadlength
Overalllength
Bestell-Nr.Kompl.,schwarz
Bestell-Nr.Verschraubung*
Bestell-Nr. Einsatz
Gewindemetrisch
Pass. zu Rohrgr. NW metrisch
Klemm-bereich
Gew. länge
Gesamt-länge
Dimensions / Dimensionen in mm
* = without insert / * = ohne Dichteinsatz
IP68GT available. Please replace “S” or “R” with “GT” (for example NVNZ-M120GT/P1-L, NVNZ-M120GT/P-L).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”oder“R”durch“GT”ersetzen(z.B.NVNZ-M120GT/P1-L,NVNZ-M120GT/P-L).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Note: –MDEmultiplesealinginsertsareavailableforthisproduct –R/PversionoffittinghastobeusedincombinationwithmultiplesealinginsertsHinweis: –MDEMehrfachdichteinsätzesindfürdiesesProdukterhältlich –FürMehrfachdichteinsätzeR/P-VersionderVerschraubungverwenden
60 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Metric, Metal / Metrisch, Metall
VA 45° elbow, metric, metal / 45° Winkel, metrisch, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVAV-M120-10 MVAV-M120-10 M12x1.5 10 12 10.0 48.5 x 37.0 NVAV-M120-5 MVAV-M120-5 M12x1.5 10 12 5.0 43.5 x 37.0 NVAV-M162-10 MVAV-M162-10 M16x1.5 12 16 10.0 53.0 x 40.5 NVAV-M162-5 MVAV-M162-5 M16x1.5 12 16 5.0 48.0 x 40.5 NVAV-M207-10 MVAV-M207-10 M20x1.5 17 20 10.0 60.5 x 51.5 NVAV-M207-6 MVAV-M207-6 M20x1.5 17 20 6.0 56.5 x 51.5 NVAV-M253-11 MVAV-M253-11 M25x1.5 23 25 11.0 70.0 x 60.5 NVAV-M253-7 MVAV-M253-7 M25x1.5 23 25 7.0 66.0 x 60.5 NVAV-M257-11 MVAV-M257-11 M25x1.5 17 20 11.0 61.5 x 54.5 NVAV-M323-13 MVAV-M323-13 M32x1.5 23 25 13.0 72.0 x 64.5 NVAV-M329-13 MVAV-M329-13 M32x1.5 29 32 13.0 77.0 x 68.0 NVAV-M329-8 MVAV-M329-8 M32x1.5 29 32 8.0 72.0 x 68.0 NVAV-M406-13 MVAV-M406-13 M40x1.5 36 40 13.0 94.0 x 87.5 NVAV-M406-8 MVAV-M406-8 M40x1.5 36 40 8.0 89.0 x 87.5 NVAV-M409-13 MVAV-M409-13 M40x1.5 29 32 13.0 77.0 x 73.0 NVAV-M506-14 MVAV-M506-14 M50x1.5 36 40 14.0 95.0 x 92.5 NVAV-M508-14 MVAV-M508-14 M50x1.5 48 50 14.0 102.0 x 101.0 NVAV-M508-9 MVAV-M508-9 M50x1.5 48 50 9.0 97.0 x 101.0 NVAV-M638-14 MVAV-M638-14 M63x1.5 48 50 14.0 102.0 x 104.0 NVAV-M638-10 MVAV-M638-10 M63x1.5 48 50 10.0 98.0 x 104.0
Order No.IP68, black
Order No.IP68, grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• Speciallyformulatedpolyamide6,nickel-platedbrassthread• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Vibration-proofconnectiontoPMAFLEXconduits• Easyassembly• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4 or OR)
• SpeziellformuliertesPolyamid6,GewindestutzenausMessingvernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4oder O-Ring) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4oderOR)
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” prior to the thread length (eg. NVAV-M120GT-10).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”vorderGewindelängeeinfügen(z.B.NVAV-M120GT-10).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
61For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX
• High-gradespeciallyformulatedpolyamide6• Easyinstallation• Highconduitpull-outstrength• Easythreadingofwiresandcables• Self-extinguishing• Freefromhalogensandphosphor• Excellentimpactstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• EinfacheMontage• HoheWellrohr-Ausreisskräfte• ProblemlosesEinziehenderEinzeladernoderKabel• Selbstverlöschend• Halogen-undphosphorfrei• HervorragendeSchlagfestigkeit• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
VB 90° curved elbow, metric, metal 90° Bogenwinkel, metrisch, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVBV-M207-10 MVBV-M207-10 M20x1.5 17 20 10.0 51.0 x 73.0 NVBV-M207-6 MVBV-M207-6 M20x1.5 17 20 6.0 47.0 x 73.0 NVBV-M257-11 MVBV-M257-11 M25x1.5 17 20 11.0 52.0 x 76.0 NVBV-M257-7 MVBV-M257-7 M25x1.5 17 20 7.0 48.0 x 76.0 NVBV-M253-11 MVBV-M253-11 M25x1.5 23 25 11.0 62.5 x 85.0 NVBV-M253-7 MVBV-M253-7 M25x1.5 23 25 7.0 58.5 x 85.0 NVBV-M323-13 MVBV-M323-13 M32x1.5 23 25 13.0 64.5 x 89.0 NVBV-M323-8 MVBV-M323-8 M32x1.5 23 25 8.0 59.5 x 89.0 NVBV-M329-13 MVBV-M329-13 M32x1.5 29 32 13.0 74.0 x 94.5 NVBV-M329-8 MVBV-M329-8 M32x1.5 29 32 8.0 69.0 x 94.5 NVBV-M409-13 MVBV-M409-13 M40x1.5 29 32 13.0 75.5 x 100.5 NVBV-M409-8 MVBV-M409-8 M40x1.5 29 32 8.0 70.5 x 100.5 NVBV-M406-13 MVBV-M406-13 M40x1.5 36 40 13.0 86.5 x 123.0 NVBV-M406-8 MVBV-M406-8 M40x1.5 36 40 8.0 81.5 x 123.0 NVBV-M506-14 MVBV-M506-14 M50x1.5 36 40 14.0 87.5 x 130.0 NVBV-M506-9 MVBV-M506-9 M50x1.5 36 40 9.0 82.5 x 130.0 NVBV-M508-14 MVBV-M508-14 M50x1.5 48 50 14.0 100.5 x 135.0 NVBV-M508-9 MVBV-M508-9 M50x1.5 48 50 9.0 95.5 x 135.0 NVBV-M638-10 MVBV-M638-10 M63x1.5 48 50 14.0 100.5 x 138.0 NVBV-M638-14 MVBV-M638-14 M63x1.5 48 50 10.0 96.5 x 138.0
Order No.IP68, black
Order No.IP68, grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” prior to the thread length (eg. NVBV-M207GT-10).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”vorderGewindelängeeinfügen(z.B.NVBV-M207GT-10).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Appropriate standard elbows of type VW are available for smaller conduit sizes NW 10 to NW 12. FürkleinereNennweitenNW10bisNW12sindStandardwinkeldesTypsVWerhältlich.
62 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Metric, Metal / Metrisch, Metall
VW 90° elbow, metric, metal / 90° Winkel, metrisch, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVWV-M120-10 MVWV-M120-10 M12x1.5 10 12 10.0 37.5 x 39.5 NVWV-M120-5 MVWV-M120-5 M12x1.5 10 12 5.0 32.5 x 39.5 NVWV-M160-10 MVWV-M160-10 M16x1.5 10 12 10.0 37.5 x 41.5 NVWV-M160-5 MVWV-M160-5 M16x1.5 10 12 5.0 32.5 x 41.5 NVWV-M162-10 MVWV-M162-10 M16x1.5 12 16 10.0 42.0 x 46.5 NVWV-M162-5 MVWV-M162-5 M16x1.5 12 16 5.0 37.0 x 46.5 NVWV-M202-10 MVWV-M202-10 M20x1.5 12 16 10.0 42.0 x 49.0 NVWV-M202-6 MVWV-M202-6 M20x1.5 12 16 6.0 38.0 x 49.0 NVWV-M207-10 MVWV-M207-10 M20x1.5 17 20 10.0 47.0 x 58.5 NVWV-M207-6 MVWV-M207-6 M20x1.5 17 20 6.0 43.0 x 58.5 NVWV-M253-11 MVWV-M253-11 M25x1.5 23 25 11.0 59.0 x 67.0 NVWV-M253-7 MVWV-M253-7 M25x1.5 23 25 7.0 55.0 x 67.0 NVWV-M329-13 MVWV-M329-13 M32x1.5 29 32 13.0 68.0 x 74.5 NVWV-M329-8 MVWV-M329-8 M32x1.5 29 32 8.0 63.0 x 74.5 NVWV-M406-13 MVWV-M406-13 M40x1.5 36 40 13.0 80.5 x 98.0 NVWV-M406-8 MVWV-M406-8 M40x1.5 36 40 8.0 75.5 x 98.0 NVWV-M508-14 MVWV-M508-14 M50x1.5 48 50 14.0 95.5 x 111.0 NVWV-M508-9 MVWV-M508-9 M50x1.5 48 50 9.0 90.5 x 111.0 NVWV-M638-14 MVWV-M638-14 M63x1.5 48 50 14.0 94.5 x 114.0 NVWV-M638-10 MVWV-M638-10 M63x1.5 48 50 10.0 90.5 x 114.0
Order No.IP68, black
Order No.IP68, grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Externaldimensions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen- masse
• High-gradeformulatedpolyamide6,threadmadeofnickel-platedbrass• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Extremelyhighthreadandsystemconnectionstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, SVN4 or OR)
• HochwertigformuliertesPolyamid6,GewindestutzenausMessing vernickelt• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• ExtremhoheGewinde-undSystemverbindungsfestigkeit• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4oderOR) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-und Gewindedichtung(NVN3,SVN4oderOR)
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” prior to the thread length (eg. NVWV-M120GT-10).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”vorderGewindelängeeinfügen(z.B.NVWV-M120GT-10).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Curved elbows of type VB are also available for sizes NW 17 to NW 48.FürdieGrössenNW17bisNW48sindauchBogenwinkeldesTypsVBerhältlich.
63For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Metal / Metrisch, Metall PMAFIX
• Straightconnectormadeofhigh-grade,speciallyformulatedpolyamide6, 90° elbow made of zinc diecast, female thread and locknut made of nickel-platedbrass,PflitschsealinginsertmadeofTPE-V• WithcorrespondingsealsIP68static/IP67dynamic cable = IP68 (10 bar)• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Extremelyhighthreadandsystemconnectionstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• TemperaturerangesealinginsertPflitsch: –40 °C to +135 °C• Contentofdelivery: IP68GT: Complete: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); sealing insert, O-ring (OR) Fitting*: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); O-ring (OR) IP68: Complete: Fittingwithovalclips(OVN2),sealinginsert, conduit seal (NVN3), O-ring (OR) Fitting*: Fittingwithovalclips(OVN2),conduitseal(NVN3), O-ring (OR)
• GeradeVerschraubungaushochwertigem,speziellformuliertenPolyamid6, 90° Winkel aus Zinkdruckguss, Innengewinde und Gegenmutter aus Messingvernickelt,Pflitsch-DichteinsatzausTPE-V• MitentsprechendemDichtungssatzIP68statisch/IP67dynamisch Kabel=IP68(10bar)• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• ExtremhoheGewinde-undSystemverbindungsfestigkeit• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• TemperaturbereichDichteinsatzPflitsch:–40 °C bis +135 °C • Lieferumfang: IP68GT: Komplett: ArmaturmitvormontiertenUniversal-Sicherheits- sperren(AFN2)undRohrdichtung(NVN3-GT); Dichteinsatz,O-Ring(OR) Verschraubung*: ArmaturmitvormontiertenUniversal-Sicherheits- sperren(AFN2)undRohrdichtung(NVN3-GT); O-Ring(OR) IP68: Komplett: ArmaturmitOval-Sperren(OVN2),Dichteinsatz, Rohrdichtung(NVN3),O-Ring(OR) Verschraubung*: ArmaturmitOval-Sperren(OVN2),Rohrdichtung (NVN3),O-Ring(OR)
VWZ straight, metric, strain relief, metal gerade, metrisch, Zugentlastung, Metall
•Inrailwayvehicleandheavymachineconstruction•Fortheseparationofdampanddryareas
•ImSchienenfahrzeugbauundschwerenMaschinenbau•ZurTrennungvonNass-undTrockenräumen
Order No.Compl., black
Order No.Fitting*
Order No.Insert
Threadmetric
Fits to cond. sizeNW metric
Terminalrange
Threadlength
Overalllength
Bestell-Nr.Kompl.,schwarz
Bestell-Nr.Verschraubung*
Bestell-Nr. Einsatz
Gewindemetrisch
Pass. zu Rohrgr. NW metrisch
Klemm-bereich
Gew. länge
Gesamt-länge
Dimensions / Dimensionen in mm
* = without insert / * = ohne Dichteinsatz
IP68GT available. Please replace “S” with “GT” (for example NVWZ-M160GT/P1).(Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”durch“GT”ersetzen(z.B.NVWZ-M160GT/P1).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
NVWZ-M160S/P1 NVWZ-M160R/P DE-M160/P1 M16x1.5 10 12 4.0 – 6.5 8.0 65.0 NVWZ-M160S/P2 DE-M160/P2 M16x1.5 10 12 5.0 – 8.0 8.0 65.0 NVWZ-M160S/P3 DE-M160/P3 M16x1.5 10 12 6.5 – 9.5 8.0 65.0 NVWZ-M202S/P1 NVWZ-M202R/P DE-M202/P1 M20x1.5 12 16 4.0 – 6.5 8.0 74.5 NVWZ-M202S/P3 DE-M202/P3 M20x1.5 12 16 6.5 – 9.5 8.0 74.5 NVWZ-M202S/P4 DE-M202/P4 M20x1.5 12 16 7.0 – 10.5 8.0 74.5 NVWZ-M207S/P1 NVWZ-M207R/P DE-M207/P1 M20x1.5 17 20 4.0 – 6.5 8.0 81.0NVWZ-M207S/P3 DE-M207/P3 M20x1.5 17 20 6.5 – 9.5 8.0 81.0 NVWZ-M207S/P4 DE-M207/P4 M20x1.5 17 20 7.0 – 10.5 8.0 81.0 NVWZ-M207S/P5 DE-M207/P5 M20x1.5 17 20 9.0 – 13.0 8.0 81.0 NVWZ-M257S/P5 NVWZ-M257R/P DE-M257/P5 M25x1.5 17 20 9.0 – 13.0 8.0 84.0NVWZ-M257S/P6 DE-M257/P6 M25x1.5 17 20 11.5 – 15.5 8.0 84.0NVWZ-M323S/P4 DE-M323/P4 M32x1.5 23 25 14.0 – 18.0 10.0 102.0
64 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX PG,Polyamide/PG, Polyamid
VN straight, PG / gerade, PG•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VND-P07MGT-11 *VNV-P07M 7 7 10 11.0 34.5 *VND-P07MGT-8 – 7 7 10 8.0 31.5 *VND-P070GT-11 *VNV-P070 7 10 12 11.0 36.5 *VND-P070GT-8 – 7 10 12 8.0 33.5 *VND-P072GT-11 *VNV-P072 7 12 16 11.0 39.0 *VND-P072GT-8 – 7 12 16 8.0 36.0 *VND-P09MGT-11 *VNV-P09M 9 7 10 11.0 34.5 *VND-P09MGT-8 – 9 10 12 8.0 31.5 *VND-P090GT-11 *VNV-P090 9 10 12 11.0 36.5 *VND-P090GT-8 – 9 10 12 8.0 33.5 *VND-P092GT-11 *VNV-P092 9 12 16 11.0 39.0 *VND-P092GT-8 – 9 12 16 8.0 36.0 *VND-P097GT-11 *VNV-P097 9 17 20 11.0 47.5 *VND-P097GT-8 – 9 17 20 8.0 44.5 *VND-P11MGT-11 *VNV-P11M 11 7 10 11.0 34.5 *VND-P11MGT-8 – 11 7 10 8.0 31.5 *VND-P110GT-11 *VNV-P110 11 10 12 11.0 36.5 *VND-P110GT-8 – 11 10 12 8.0 33.5 *VND-P112GT-11 *VNV-P112 11 12 16 11.0 39.0 *VND-P112GT-8 – 11 12 16 8.0 36.0 *VND-P117GT-11 *VNV-P117 11 17 20 11.0 47.5 *VND-P117GT-8 – 11 17 20 8.0 44.5 *VND-P13MGT-11 *VNV-P13M 13.5 7 10 11.0 34.5 *VND-P13MGT-8 – 13.5 7 10 8.0 31.5 *VND-P130GT-11 *VNV-P130 13.5 10 12 11.0 36.5 *VND-P130GT-8 – 13.5 10 12 8.0 33.5 *VND-P132GT-11 *VNV-P132 13.5 12 16 11.0 39.0 *VND-P132GT-8 – 13.5 12 16 8.0 36.0 *VND-P137GT-11 *VNV-P137 13.5 17 20 11.0 47.5 *VND-P137GT-8 – 13.5 17 20 8.0 44.0 *VND-P160GT-11 – 16 10 12 11.0 36.5 *VND-P160GT-8 – 16 10 12 8.0 33.5 *VND-P162GT-11 *VNV-P162 16 12 16 11.0 39.0 *VND-P163GT-11 *VNV-P163 16 23 25 11.0 51.5 *VND-P163GT-8 – 16 23 25 8.0 48.0 *VND-P167GT-11 *VNV-P167 16 17 20 11.0 47.5 *VND-P167GT-8 – 16 17 20 8.0 44.5 *VND-P213GT *VNV-P213 21 23 25 12.0 52.0 *VND-P296GT *VNV-P296 29 36 40 12.0 67.5 *VND-P299GT *VNV-P299 29 29 32 12.0 53.0 *VND-P366GT *VNV-P366 36 36 40 13.0 66.0 *VND-P368GT *VNV-P368 36 48 50 13.0 68.5 *VND-P428GT *VNV-P428 42 48 50 13.0 68.5 *VND-P488GT *VNV-P488 48 48 50 13.0 66.5
Order No.IP66
Order No.IP68
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Overall length
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithoval
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
65For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PG,Polyamide/PG, Polyamid PMAFIX
VNZ straight, PG, strain relief / gerade, PG, Zugentlastung•Forcableprotectionsystemsinawiderangeofapplications•Forseparationofdampanddryareas
•FürKabelschutzineinembreitenAnwendungsgebiet•ZurTrennungvonNass-undTrockenräumen
*VNDZ-P090GT *VNZ-P090S 9 10 12 4.0 – 8.0 7.5 56.0 *VNDZ-P112GT *VNZ-P112S 11 12 16 5.0 – 10.0 8.0 60.5*VNDZ-P132GT *VNZ-P132S 13.5 12 16 6.0 – 12.0 9.0 62.0*VNDZ-P137GT *VNZ-P137S 13.5 17 20 6.0 – 12.0 9.0 69.0*VNDZ-P167GT *VNZ-P167S 16 17 20 10.0 – 14.0 10.0 72.0*VNDZ-P163GT *VNZ-P163S 16 23 25 10.0 – 14.0 10.0 79.0*VNDZ-P213GT *VNZ-P213S 21 23 25 13.0 – 18.0 11.0 82.0*VNDZ-P299GT *VNZ-P299S 29 29 32 18.0 – 25.0 11.0 85.0*VNDZ-P366GT *VNZ-P366S 36 36 40 22.0 – 32.0 13.0 112.0*VNDZ-P488GT *VNZ-P488S 48 48 50 34.0 – 44.0 14.0 112.0
Order No.IP66
Order No.IP68
ThreadPG
Fits to conduit sizeNW metric
Terminalrange
Threadlength
Overalllength
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindePG
Passend zu RohrgrösseNW metrisch
Klemm-bereich
Gewinde- länge
Gesamt-länge
Dimensions / Dimensionen in mm
* = Replace with “B” to order black or “S” to order grey /*=ErsetzenSie“B”fürschwarzoder“S”fürgrau
IP68GT available. Please replace “S” at the end with “GT” (for example BVNZ-P112GT). (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”amEndedurch“GT”ersetzen(z.B.BVNZ-P112GT).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Note:MDEmultiplesealinginsertsareavailableforthisproduct.Hinweis: MDEMehrfachdichteinsätzesindfürdiesesProdukterhältlich.
• High-gradeformulatedpolyamide6,veryhighimpactresistance• Easyinstallation:simplepushtheconduitin• Highconduitpull-outstrength• Integratedstrainreliefoptimallyholdsandsealscables• Ifseveralconductorsareusedwiththeconnectormultiplesealing inserts should be considered• Verygoodchemicalproperties,freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2), strain relief insert IP68GT: Fittingwithpre-assembleduniversalclips(AFN2)andconduit seal (NVN3-GT); strain relief insert and thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),strainreliefinsert,conduitand thread seal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• EinfachsteMontage:Rohreinschieben,hoheWellrohr-Ausreisskräfte• MitintegrierterZugentlastungwerdendieKabelgehaltenundoptimal abgedichtet• WerdenmehrereLeiterdurchdieVerschraubunggeführtsind Mehrfachdichteinsätze zu verwenden• SehrgutechemischeEigenschaften,halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontierterUniversal-Sicherheitssperre(AFN2) undRohrdichtung(NVN3-GT);Zugentlastungs-Einsatzund Gewindedichtung IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
66 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX PG,Polyamide/PG, Polyamid
VA 45° elbow, PG / 45° Winkel, PG
VB 90° curved elbow, PG / 90° Bogenwinkel, PG
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VAD-P090GT *VAV-P090 9 10 12 11.0 43.0 x 37.0*VAD-P112GT *VAV-P112 11 12 16 11.0 48.0 x 40.0*VAD-P132GT *VAV-P132 13.5 12 16 11.0 48.0 x 41.5*VAD-P137GT *VAV-P137 13.5 17 20 11.0 55.5 x 51.5*VAD-P167GT *VAV-P167 16 17 20 11.0 55.5 x 51.5 *VAD-P213GT *VAV-P213 21 23 25 11.0 63.0 x 58.0 *VAD-P299GT *VAV-P299 29 29 32 12.0 69.0 x 66.0 *VAD-P366GT *VAV-P366 36 36 40 13.0 86.0 x 86.0 *VAD-P488GT *VAV-P488 48 48 50 13.0 94.0 x 100.0
*VBD-P167GT *VBV-P167 16 17 20 11.0 47.5 x 73.0*VBD-P213GT *VBV-P213 21 23 25 12.0 57.5 x 85.0 *VBD-P299GT *VBV-P299 29 29 32 12.0 67.5 x 96.0 *VBD-P366GT *VBV-P366 36 36 40 13.0 79.0 x 123.0 *VBD-P488GT *VBV-P488 48 48 50 13.0 92.5 x 135.0
Order No.IP66
Order No.IP68
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Order No.IP66
Order No.IP68
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Smoothelbowallowseasyguidancethroughconnector• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• RundeFührunginnerhalbderVerschraubung• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
Appropriate standard elbows of type VW are available for smaller conduit sizes NW 07 to NW 12. FürkleinereNennweitenNW07bisNW12sindStandardwinkeldesTypsVWerhältlich.
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
67For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PG,Polyamide/PG, Polyamid PMAFIX
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4) • Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
VW 90° elbow, PG / 90° Winkel, PG•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VWD-P07MGT-11 *VWV-P07M 7 7 10 11.0 32.0 x 35.0 *VWD-P07MGT-8 – 7 7 10 8.0 29.0 x 35.0 *VWD-P070GT-11 *VWV-P070 7 10 12 11.0 34.0 x 39.5 *VWD-P070GT-8 – 7 10 12 8.0 31.0 x 39.5 *VWD-P072GT-11 *VWV-P072 7 12 16 11.0 38.5 x 44.5 *VWD-P072GT-8 – 7 12 16 8.0 35.5 x 44.5 *VWD-P09MGT-11 *VWV-P09M 9 7 10 11.0 32.0 x 36.5 *VWD-P09MGT-8 – 9 7 10 8.0 29.0 x 36.5 *VWD-P090GT-11 *VWV-P090 9 10 12 11.0 34.0 x 39.5 *VWD-P090GT-8 – 9 10 12 8.0 31.0 x 39.5 *VWD-P092GT-11 *VWV-P092 9 12 16 11.0 38.5 x 44.5 *VWD-P092GT-8 – 9 12 16 8.0 35.5 x 44.5 *VWD-P11MGT-11 *VWV-P11M 11 7 10 11.0 32.0 x 38.0 *VWD-P11MGT-8 – 11 7 10 8.0 29.0 x 38.0 *VWD-P110GT-11 *VWV-P110 11 10 12 11.0 34.0 x 41.0 *VWD-P110GT-8 – 11 10 12 8.0 31.0 x 41.0 *VWD-P112GT-11 *VWV-P112 11 12 16 11.0 38.5 x 46.0 *VWD-P112GT-8 – 11 12 16 8.0 35.5 x 46.0 *VWD-P13MGT-11 *VWV-P13M 13.5 7 10 11.0 32.0 x 39.5 *VWD-P13MGT-8 – 13.5 7 10 8.0 29.0 x 39.5 *VWD-P130GT-11 *VWV-P130 13.5 10 12 11.0 34.0 x 42.5 *VWD-P130GT-8 – 13.5 10 12 8.0 31.0 x 42.5 *VWD-P132GT-11 *VWV-P132 13.5 12 16 11.0 38.5 x 47.5 *VWD-P132GT-8 – 13.5 12 16 8.0 35.5 x 47.5 *VWD-P137GT-11 *VWV-P137 13.5 17 20 11.0 43.5 x 58.5 *VWD-P137GT-8 – 13.5 17 20 8.0 40.5 x 58.5 *VWD-P167GT-11 *VWV-P167 16 17 20 11.0 43.5 x 58.5 *VWD-P167GT-8 – 16 17 20 8.0 40.5 x 58.5 *VWD-P213GT *VWV-P213 21 23 25 12.0 54.0 x 67.0 *VWD-P299GT *VWV-P299 29 29 32 12.0 61.5 x 74.5 *VWD-P366GT *VWV-P366 36 36 40 13.0 72.0 x 98.0 *VWD-P488GT *VWV-P488 48 48 50 13.0 85.5 x 111.0
Order No.IP66
Order No.IP68
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
Curved elbows of type VB are available for the sizes NW 17 to NW 48.FürdieGrössenNW17bisNW48sindauchBogenwinkeldesTypsVBerhältlich.
68 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX PG,Metal/PG, Metall
VN straight, PG, metal / gerade, PG, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVNV-P090 MVNV-P090 9 10 12 12.0 42.0 NVNV-P112 MVNV-P112 11 12 16 12.0 45.0 NVNV-P137 MVNV-P137 13.5 17 20 13.0 54.0 NVNV-P167 MVNV-P167 16 17 20 13.0 54.0 NVNV-P213 MVNV-P213 21 23 25 14.0 57.0 NVNV-P293 MVNV-P293 29 23 25 14.0 57.0 NVNV-P299 MVNV-P299 29 29 32 14.0 58.5 NVNV-P366 MVNV-P366 36 36 40 17.0 75.5 NVNV-P488 MVNV-P488 48 48 50 17.0 75.5
Order No.IP68, black
Order No.IP68, grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-gradespeciallyformulatedpolyamide6, thread made of nickel-plated brass• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Extremelyhighthreadandsystemconnectionstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4 or OR)
• Hochwertiges,speziellformuliertesPolyamid6, Gewindestutzen aus Messing vernickelt• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• ExtremhoheGewinde-undSystemverbindungsfestigkeit• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4oder O-Ring) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
69For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PG,Metal/PG, Metall PMAFIX
• High-grade,speciallyformulatedpolyamide6,threadmadeof nickel-plated brass, sealing inserts made from TPE-V• Veryhighimpactresistance• Withintegratedstrainreliefandoptimalingressprotectionatthecable (up to IP68 / 10 bar)• Highthreadandsystemconnectionstrength• Vibration-resistantconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• TemperaturerangesealinginsertPflitsch:–40 °C to +135 °C• Contentofdelivery: IP68GT: Complete: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); sealing insert, O-ring (OR) Fitting*: Fittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT); O-ring (OR) IP68: Complete: Fittingwithovalclips(OVN2),sealinginsert, conduit seal (NVN3), O-ring (OR) Fitting*: Fittingwithovalclips(OVN2),conduitseal(NVN3), O-ring (OR) Insert: Sealinginsert• Forseveralconductorsmultiplesealinginsertsareavailable(MDE) • Hochwertiges,speziellformuliertesPolyamid6,Gewindestutzenaus Messingvernickelt,DichteinsatzausTPE-V• HervorragendeSchlagfestigkeit• MitintegrierterZugentlastungundoptimalerAbdichtungüberdasKabel (biszuIP68/10bar)• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Temperaturbereich Dichteinsatz Pflitsch: –40 °C bis +135 °C• Lieferumfang: IP68GT: Komplett: ArmaturmitvormontiertenUniversal- Sicherheitssperren(AFN2)undRohrdichtung (NVN3-GT);Dichteinsatz,O-Ring(OR) Verschraubung*: ArmaturmitvormontiertenUniversal- Sicherheitssperren(AFN2)undRohrdichtung (NVN3-GT);O-Ring(OR) IP68: Komplett: ArmaturmitOval-Sperren(OVN2),Dichteinsatz, Rohrdichtung(NVN3),O-Ring(OR) Verschraubung*: ArmaturmitOval-Sperren(OVN2),Rohrdichtung (NVN3),O-Ring(OR) Einsatz: Dicht-Einsatz• FürmehrereLeitersindMehrfachdichteinsätzeerhältlich(MDE)
VNZ straight, PG, strain relief, metal / gerade, PG, Zugentlastung, Metall•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
NVNZ-P090S/P1 NVNZ-P090R/P DE-P090/P1 09 10 12 4.0 – 6.5 6.0 49.5 NVNZ-P090S/P3 NVNZ-P090R/P DE-P090/P3 09 10 12 6.5 – 9.5 6.0 49.5 NVNZ-P110S/P1 NVNZ-P110R/P DE-P110/P1 11 10 12 4.0 – 6.5 6.0 52.0 NVNZ-P110S/P3 NVNZ-P110R/P DE-P110/P3 11 10 12 6.5 – 9.5 6.0 52.0 NVNZ-P112S/P1 NVNZ-P112R/P DE-P112/P1 11 12 16 4.0 – 6.5 6.0 53.5 NVNZ-P112S/P3 NVNZ-P112R/P DE-P112/P3 11 12 16 6.5 – 9.5 6.0 53.5 NVNZ-P112S/P4 NVNZ-P112R/P DE-P112/P4 11 12 16 7.0 – 10.5 6.0 53.5 NVNZ-P160S/P1 NVNZ-P160R/P1 DE-P110/P1 16 10 16 4.5 – 6.5 6.5 52.5 NVNZ-P167S/P3 NVNZ-P167R/P DE-P167/P3 16 17 20 6.5 – 9.5 6.5 61.0 NVNZ-P167S/P4 NVNZ-P167R/P DE-P167/P4 16 17 20 7.0 – 10.5 6.5 61.0 NVNZ-P167S/P5 NVNZ-P167R/P DE-P167/P5 16 17 20 9.0 – 13.0 6.5 61.0 NVNZ-P167S/P6 NVNZ-P167R/P DE-P167/P6 16 17 20 11.5 – 15.5 6.5 61.0 NVNZ-P213S/P1 NVNZ-P213R/P DE-P213/P1 21 23 25 7.0 – 10.5 7.0 72.0 NVNZ-P213S/P4 NVNZ-P213R/P DE-P213/P4 21 23 25 14.0 – 18.0 7.0 72.0 NVNZ-P213S/P5 NVNZ-P213R1/P DE-P213/P5 21 23 25 17.0 – 20.5 7.0 72.0 NVNZ-P299S/P3 NVNZ-P299R/P DE-P299/P3 29 29 32 17.0 – 20.5 8.0 73.5 NVNZ-P299S/P4 NVNZ-P299R/P DE-P299/P4 29 29 32 20.0 – 25.0 8.0 73.5 NVNZ-P299S/P5 NVNZ-P299R/P DE-P299/P5 29 29 32 24.0 – 28.0 8.0 73.5 NVNZ-P366S/P1 NVNZ-P366R/P DE-P366/P1 36 36 40 27.0 – 32.0 9.0 88.0 NVNZ-P366S/P2 NVNZ-P366R/P DE-P366/P2 36 36 40 29.0 – 34.0 9.0 88.0 NVNZ-P366S/P3 NVNZ-P366R/P DE-P366/P3 36 36 40 32.0 – 36.0 9.0 88.0 NVNZ-P488S/P1 NVNZ-P488R/P DE-P488/P1 48 48 50 35.0 – 40.0 10.0 90.5 NVNZ-P488S/P2 NVNZ-P488R/P DE-P488/P2 48 48 50 39.0 – 44.0 10.0 90.5
Order No. IP68Complete, black
Order No. IP68Fitting*
Order No.Insert
ThreadPG
Fits to cond. sizeNW metric
Terminal range
Threadlength
Overalllength
Bestell-Nr.IP68Komplett,schwarz
Bestell-Nr.Verschraubung*
Bestell-Nr.Einsatz
GewindePG
Passend zu Rohrgr.NW metrisch
Klemm-bereich
Gewinde- länge
Gesamt- länge
Dimensions / Dimensionen in mm
IP68GT available. Please replace “S” or “R” with “GT” (for example NVNZ-P112GT/P1) (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“S”oder“R”durch“GT”ersetzen(z.B.NVNZ-P112GT/P1)(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = without insert / * = ohne Dichteinsatz
Note: –MDEmultiplesealinginsertsareavailableforthisproduct –R/PversionoffittinghastobeusedincombinationwithmultiplesealinginsertsHinweis: –MDEMehrfachdichteinsätzesindfürdiesesProdukterhältlich –FürMehrfachdichteinsätzeR/P-VersionderVerschraubungverwenden
70 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX PG,Metal/PG, Metall
VA 45° elbow, PG, metal / 45° Winkel, PG, Metall
VB 90° curved elbow, PG, metal / 90° Bogenwinkel, PG, Metall
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
NVAV-P090 MVAV-P090 9 10 12 12.0 50.5 x 37.0 NVAV-P112 MVAV-P112 11 12 16 12.0 55.0 x 40.5 NVAV-P137 MVAV-P137 13.5 17 20 13.0 63.5 x 50.0 NVAV-P167 MVAV-P167 16 17 20 13.0 63.5 x 50.0 NVAV-P213 MVAV-P213 21 23 25 14.0 73.0 x 60.5 NVAV-P299 MVAV-P299 29 29 32 14.0 78.0 x 68.0 NVAV-P366 MVAV-P366 36 36 40 17.0 98.0 x 87.5 NVAV-P488 MVAV-P488 48 48 50 17.0 105.0 x 101.0
NVBV-P167 MVBV-P167 16 17 20 13.0 54.0 x 73.0 NVBV-P213 MVBV-P213 21 23 25 14.0 65.5 x 85.0 NVBV-P299 MVBV-P299 29 29 32 14.0 75.0 x 96.0 NVBV-P366 MVBV-P366 36 36 40 17.0 90.5 x 123.0 NVBV-P488 MVBV-P488 48 48 50 17.0 103.5 x 135.0
Order No.IP68, black
Order No.IP68, grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Order No.IP68, black
Order No.IP68, grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• Speciallyformulatedpolyamide6,nickel-platedbrassthread• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Vibration-proofconnectiontoPMAFLEXconduits• Easyassembly• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4 or OR)
• SpeziellformuliertesPolyamid6,GewindestutzenausMessingvernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4oder O-Ring) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4oderOR)
• Speciallyformulatedpolyamide6,nickel-platedbrassthread• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Vibration-proofconnectiontoPMAFLEXconduits• Easyassembly• Highconduitpull-outstrength• Verygoodchemicalproperties• Polyamidefreefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4 or OR) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4 or OR)
• SpeziellformuliertesPolyamid6,GewindestutzenausMessingvernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfacheMontage• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4oder O-Ring) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4oderOR)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Appropriate standard elbows of type VW are also available for smaller conduit sizes NW 07 to NW 12.FürkleinereNennweitenNW07bisNW12sindauchStandardwinkeldesTypsVWerhältlich.
71For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PG,Metal/PG, Metall PMAFIX
• High-grade,speciallyformulatedpolyamide6,threadmadeof nickel-plated brass• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties•Polyamidefreefromhalogensandcadmium• Extremelyhighthreadandsystemconnectionstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4) • Hochwertiges,speziellformuliertesPolyamid6,Gewindestutzenaus Messing vernickelt• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfreiesPolyamid• ExtremhoheGewinde-undSystemverbindungsfestigkeit• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-und Gewindedichtung(NVN3,SVN4)
VW 90° elbow, PG, metal / 90° Winkel, PG, Metall•Inrailwayvehicleandheavymachineconstruction •ImSchienenfahrzeugbauundschwerenMaschinenbau
NVWV-P090 MVWV-P090 9 10 12 12.0 39.5 x 39.5 NVWV-P112 MVWV-P112 11 12 16 12.0 45.5 x 45.0 NVWV-P137 MVWV-P137 13.5 17 20 13.0 50.0 x 58.5 NVWV-P167 MVWV-P167 16 17 20 13.0 50.0 x 58.5 NVWV-P213 MVWV-P213 21 23 25 14.0 62.0 x 67.0 NVWV-P299 MVWV-P299 29 29 32 14.0 69.0 x 74.5 NVWV-P366 MVWV-P366 36 36 40 17.0 83.5 x 98.0 NVWV-P488 MVWV-P488 48 48 50 17.0 96.5 x 111.0
Order No.IP68, black
Order No.IP68, grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP68,schwarz
Bestell-Nr.IP68,grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
Curved elbows of type VB are available for the sizes NW 17 to NW 48.FürdieGrössenNW17bisNW48sindauchBogenwinkeldesTypsVBerhältlich.
72 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX GAS,Polyamide/GAS, Polyamid
VN straight, GAS / gerade, GAS
VA 45° elbow, GAS / 45° Winkel, GAS
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VND-G00MGT *VNV-G00M ¼" 7 10 11.0 34.5 *VND-G000GT *VNV-G000 ¼" 10 12 11.0 36.5 *VND-G010GT *VNV-G010 3⁄8" 10 12 11.0 36.5 *VND-G012GT *VNV-G012 3⁄8" 12 16 11.0 39.0 *VND-G022GT *VNV-G022 ½" 12 16 13.0 41.0 *VND-G027GT *VNV-G027 ½" 17 20 13.0 49.5 *VND-G043GT *VNV-G043 ¾" 23 25 14.0 54.0 *VND-G069GT *VNV-G069 1" 29 32 15.0 56.0 *VND-G076GT *VNV-G076 1 ¼" 36 40 18.0 71.0 *VND-G088GT *VNV-G088 1 ½" 48 50 18.0 71.5 *VND-G098GT *VNV-G098 2" 48 50 18.0 71.5
*VAD-G000GT *VAV-G000 ¼" 10 12 11.0 43.5 x 37.0 *VAD-G012GT *VAV-G012 3⁄8" 12 16 11.0 48.0 x 40.0 *VAD-G027GT *VAV-G027 ½" 17 20 13.0 57.5 x 51.5 *VAD-G043GT *VAV-G043 ¾" 23 25 14.0 67.0 x 60.0 *VAD-G069GT *VAV-G069 1" 29 32 15.0 73.5 x 67.0 *VAD-G076GT *VAV-G076 1 ¼" 36 40 18.0 91.5 x 85.5 *VAD-G088GT – 1 ½" 48 50 18.0 99.0 x 96.0 *VAD-G098GT *VAV-G098 2" 48 50 18.0 99.0 x 101.0
Order No.IP66
Order No.IP68
ThreadGAS
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeGAS
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP66
Order No.IP68
ThreadGAS
Fits to conduit sizeNW metric
Threadlength
External dimension
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeGAS
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
73For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
GAS,Polyamide/GAS, Polyamid PMAFIX
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4) • Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
VW 90° elbow, GAS / 90° Winkel, GAS•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VWD-G00MGT *VWV-G00M ¼" 7 10 11.0 32.0 x 36.5 *VWD-G000GT *VWV-G000 ¼" 10 12 11.0 34.0 x 39.5 *VWD-G010GT *VWV-G010 3⁄8" 10 12 11.0 34.0 x 40.5 *VWD-G012GT *VWV-G012 3⁄8" 12 16 11.0 38.5 x 46.0 *VWD-G022GT *VWV-G022 ½" 12 16 13.0 40.5 x 47.5 *VWD-G027GT *VWV-G027 ½" 17 20 13.0 45.5 x 58.5 *VWD-G043GT *VWV-G043 ¾" 23 25 14.0 56.0 x 66.5 *VWD-G069GT *VWV-G069 1" 29 32 15.0 64.5 x 73.5 *VWD-G076GT *VWV-G076 1 ¼" 36 40 18.0 77.0 x 96.0 *VWD-G088GT *VWV-G088 1 ½" 48 50 18.0 90.5 x 106.0 *VWD-G098GT *VWV-G098 2" 48 50 18.0 90.5 x 111.0
Order No.IP66
Order No.IP68
ThreadGAS
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeGAS
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
74 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX NPT, Polyamide / NPT, Polyamid
VN straight, NPT / gerade, NPT
VA 45° elbow, NPT / 45° Winkel, NPT
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VND-N022GT *VNV-N022 ½" 12 16 13.0 41.5 *VND-N027GT *VNV-N027 ½" 17 20 13.0 49.5 *VND-N043GT *VNV-N043 ¾" 23 25 14.0 54.0 *VND-N069GT *VNV-N069 1" 29 32 15.0 56.0 *VND-N076GT *VNV-N076 1 ¼" 36 40 18.0 71.0 *VND-N088GT *VNV-N088 1 ½" 48 50 18.0 71.5*VND-N098GT *VNV-N098 2" 48 50 18.0 71.5
*VAD-N022GT *VAV-N022 ½" 12 16 13.0 50.0 x 41.5 *VAD-N027GT *VAV-N027 ½" 17 20 13.0 57.5 x 51.5 *VAD-N043GT *VAV-N043 ¾" 23 25 14.0 67.0 x 60.0 *VAD-N069GT *VAV-N069 1" 29 32 15.0 73.5 x 67.0 *VAD-N076GT *VAV-N076 1 ¼" 36 40 18.0 91.5 x 85.5 *VAD-N088GT *VAV-N088 1 ½" 48 50 18.0 99.0 x 96.0 *VAD-N098GT *VAV-N098 2" 48 50 18.0 99.0 x 101.0
Order No.IP66
Order No.IP68
ThreadNPT
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeNPT
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP66
Order No.IP68
ThreadNPT
Fits to conduit sizeNW metric
Threadlength
External dimension
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeNPT
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung (SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, SVN4)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT);Gewindedichtung(SVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
75For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
NPT, Polyamide / NPT, Polyamid PMAFIX
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Easymounting:simpleconduitpush-ininstallation• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT); thread seal (SVN4) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal(NVN3, SVN4) • Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• EinfachsteMontage:Rohreinschieben• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);GewindedichtungenSVN4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,SVN4)
• High-grade,speciallyformulatedpolyamide6• StandardflangesealFGO4madefromEPDM,flangesealFGO4/01 made from NBR on request• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties,freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• TemperaturerangewithFG04: –40 °C to +105 °C• TemperaturerangewithFG04/01: –25 °C to +70 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2), flangeseal(FG04) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduitseal(NVN3-GT);flangeseal(FGO4) IP68: Fittingwithovalclips(OVN2),conduitandflangeseal(NVN3, FG04) • Hochwertiges,speziellformuliertesPolyamid6• StandardFlanschdichtungFG04ausEPDM,FG04/01ausNBRaufAnfrage• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften,halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• TemperaturbereichmitFG04: –40 °C bis +105 °C ; • TemperaturbereichmitFG04/01:–25°Cbis+70°C;• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2), Flansch-Dichtung(FG04) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Flanschdichtung(FGO4) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undFlanschdichtung (NVN3,FG04)
VW 90° elbow, NPT / 90° Winkel, NPT
VO Flange 90° / Flansch 90°
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VWD-N022GT *VWV-N022 ½" 12 16 13.0 40.5 x 47.5 *VWD-N027GT *VWV-N027 ½" 17 20 13.0 45.5 x 58.5 *VWD-N043GT *VWV-N043 ¾" 23 25 14.0 56.0 x 66.5 *VWD-N069GT *VWV-N069 1" 29 32 15.0 64.5 x 73.5 *VWD-N076GT *VWV-N076 1 ¼" 36 40 18.0 77.0 x 96.0 *VWD-N088GT *VWV-N088 1 ½" 48 50 18.0 90.5 x 106.0 *VWD-N098GT *VWV-N098 2" 48 50 18.0 90.5 x 111.0
*VOD-P167GT *VOV-P167 17 20 46.0 x 66.0 x 35.5 2 x M5*VOD-P213GT *VOV-P213 23 25 65.5 x 70.0 x 43.0 2 x M6*VOD-P299GT *VOV-P299 29 32 67.0 x 78.0 x 49.5 4 x M6*VOD-P366GT *VOV-P366 36 40 85.0 x 102.0 x 65.5 4 x M6*VOD-P488GT *VOV-P488 48 50 86.0 x 119.0 x 77.5 4 x M6
Order No.IP66
Order No.IP68
ThreadNPT
Fits to conduit sizeNW metric
Threadlength
Externaldimesions
Bestell-Nr.IP66
Bestell-Nr.IP68
GewindeNPT
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Order No.IP66
Order No.IP68
Fits to conduit sizeNW metric
DimensionsWidth x Length x Depth
Screw sizes
Bestell-Nr.IP66
Bestell-Nr.IP68
Passend zu RohrgrösseNW metrisch
Dimensionen BreitexLängexTiefe
Schrauben-grössen
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
IP68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
Flange / Flansch
76 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Female Thread Adapters, Metric / Innengewindeadapter, Metrisch
VI metric / metrisch
VI metric, metal / metrisch, Metall
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Inmachineandrailwayconstructionandindustry •ImMaschinen-undSchienenfahrzeugbauundIndustrie
BVID-M12MGT – M12x1.5 7 10 8.0 32.0 BVID-M160GT BVIR-M160 M16x1.5 10 12 8.0 33.5 BVID-M162GT BVIR-M162 M16x1.5 12 16 8.0 36.5
– BVIR-M202 M20x1.5 12 16 8.0 36.5 BVID-M207GT BVIR-M207 M20x1.5 17 20 8.0 44.5 BVID-M253GT BVIR-M253 M25x1.5 23 25 8.0 48.5
– BVIR-M257 M25x1.5 17 20 8.0 44.5 BVID-M329GT BVIR-M329 M32x1.5 29 32 10.0 51.5 BVID-M406GT BVIR-M406 M40x1.5 36 40 10.0 65.5 BVID-M508GT BVIR-M508 M50x1.5 48 50 10.0 65.5 BVID-M638GT BVIR-M638 M63x1.5 48 50 10.0 65.5
NVIR-M120 M12x1.5 10 12 7.5 35.5 NVIR-M160 M16x1.5 10 12 9.0 40.5 NVIR-M162 M16x1.5 12 16 9.0 41.0 NVIR-M207 M20x1.5 17 20 10.0 50.0 NVIR-M253 M25x1.5 23 25 10.0 56.0 NVIR-M329 M32x1.5 29 32 11.0 55.5 NVIR-M406 M40x1.5 36 40 13.0 71.0 NVIR-M508 M50x1.5 48 50 15.0 73.0 NVIR-M638 M63x1.5 48 50 17.5 78.0
Order No.IP66, black
Order No.IP68, black
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66,schwarz
Bestell-Nr.IP68,schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP68, black
Threadmetric
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP68,schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIR:IP68 static / IP67 dynamic, conduit side VID:IP66 static / IP54 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIR:IP68statisch/IP67dynamisch, rohrseitig VID: IP66statisch/IP54dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
• High-grade,speciallyformulatedpolyamide6,threadmadeof nickel-plated brass• Veryhighimpactresistance• Highthreadandsystemconnectionstrengths• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIR:IP68 static / IP67 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6, Messing-Gewindestutzen vernickelt• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIR:IP68statisch/IP67dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
77For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
FemaleThreadAdapters,PG/Innengewindeadapter, PG PMAFIX
FI/VI PG / PG
VI PG, metal / PG, Metall
•Formachine,vehicleandtractionbuilding •FürdenMaschinen-Fahrzeug-undBahnbau
•Inmachineandrailwayconstructionandindustry •ImMaschinen-undSchienenfahrzeugbauundIndustrie
BFIL-P07M – 7 7 10 8.0 29.0 BFIL-P070 – 7 10 12 8.0 34.5
– BVIR-P070 7 10 12 8.0 33.5 BFIL-P090 – 9 10 12 8.0 32.5
– BVIR-P090 9 10 12 8.0 33.5 BFIL-P112 – 11 12 16 8.0 32.5
– BVIR-P112 11 12 16 8.0 36.5 BFIL-P117 – 11 17 20 8.0 35.0 BFIL-P132 – 13.5 12 16 8.0 32.5 BFIL-P137 – 13.5 17 20 8.0 33.5 BFIL-P160 – 16 10 12 7.0 37.0 BFIL-P167 – 16 17 20 8.0 33.5
– BVIR-P167 16 17 20 8.0 44.5 BFIL-P217 – 21 17 20 10.5 35.5 BFIL-P213 – 21 23 25 8.0 39.0 BFIL-P293 – 29 23 25 9.0 42.0 BFIL-P299 – 29 29 32 9.0 43.0 BFIL-P363 – 36 23 25 12.0 51.0 BFIL-P369 – 36 29 32 16.0 52.0 BFIL-P366 – 36 36 25 13.0 64.0 BFIL-P488 – 48 48 50 13.0 65.0
NVIZR-P07M 7 7 10 6.0 33.0 NVIZR-P090 9 10 12 9.0 37.5 NVIZR-P110 11 10 12 9.0 39.5 NVIZR-P112 11 12 16 9.0 41.5 NVIZR-P167 16 17 20 9.5 49.5 NVIZR-P213 21 23 25 10.0 56.5 NVIZR-P299 29 29 32 12.5 56.5 NVIZR-P366 36 36 40 13.0 73.0 NVIZR-P488 48 48 50 14.0 75.0
Order No.IP67, black
Order No.IP68, black
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP67,schwarz
Bestell-Nr.IP68,schwarz
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP68, black
ThreadPG
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP68,schwarz
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIR:IP68 static / IP67 dynamic, conduit side FIL:IP67 static / IP65 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP67: Fittingwithovalclips(OVN2),conduitseal(NFN3) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIR:IP68statisch/IP67dynamisch, rohrseitig FIL:IP67statisch/IP65dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP67: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NFN3) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
• High-grade,speciallyformulatedpolyamide6, thread made of nickel-plated brass• Veryhighimpactresistance• Highthreadandsystemconnectionstrengths• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIZR:IP68 static / IP67 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6, Messing-Gewindestutzen vernickelt• HoheGewinde-undSystemverbindungsfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIZR:IP68statisch/IP67dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
78 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Female Thread Adapters, UNEF / Innengewindeadapter, UNEF
VI UNEF, for AMP CPC Series / UNEF, für AMP CPC Serie
VI UNEF, for Souriau UTG-6/ITT Cannon Trident UNEF, für Souriau UTG-6/ITT Cannon Trident
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
BVIDA-U15MGT BVIRA-U15M 5⁄8"-24 7 10 8.0 31.5 BVIDA-U150GT BVIRA-U150 5⁄8"-24 10 12 8.0 33.5 BVIDA-U152GT BVIRA-U152 5⁄8"-24 12 16 8.0 36.5 BVIDA-U180GT BVIRA-U180 ¾"-20 10 12 8.0 33.5 BVIDA-U182GT BVIRA-U182 ¾"-20 12 16 8.0 36.5 BVIDA-U187GT BVIRA-U187 ¾"-20 17 20 8.0 44.5 BVIDA-U232GT BVIRA-U232 15⁄16"-20 12 16 8.0 38.5 BVIDA-U237GT BVIRA-U237 15⁄16"-20 17 20 8.0 46.5 BVIDA-U233GT BVIRA-U233 15⁄16"-20 23 25 8.0 48.5 BVIDA-U347GT BVIRA-U347 1 3⁄8"-18 17 20 8.0 46.5 BVIDA-U343GT BVIRA-U343 1 3⁄8"-18 23 25 8.0 48.5 BVIDA-U402GT BVIRA-U402 1 5⁄8"-18 12 16 7.0 55.5 BVIDA-U407GT BVIRA-U407 1 5⁄8"-18 17 20 7.0 61.5 BVIDA-U403GT BVIRA-U403 1 5⁄8"-18 23 25 7.0 60.5
BVIDB-U162GT BVIRB-U162 11⁄16"-24 12 16 4.0 43.5 BVIDB-U202GT BVIRB-U202 13⁄16"-20 12 16 4.5 44.0 BVIDB-U232GT BVIRB-U232 15⁄16"-20 12 16 4.5 49.0 BVIDB-U237GT BVIRB-U237 15⁄16“-20 17 20 4.5 52.0 BVIDB-U267GT BVIRB-U267 1 1⁄16“-18 17 20 4.5 52.0 BVIDB-U297GT BVIRB-U297 1 3⁄16“-18 17 20 6.5 55.5 BVIDB-U293GT BVIRB-U293 1 3⁄16“-18 23 25 6.5 52.0 BVIDB-U323GT BVIRB-U323 1 5⁄16“-18 23 25 6.5 52.0 BVIDB-U357GT BVIRB-U357 1 7⁄16“-18 17 20 6.5 58.5 BVIDB-U353GT BVIRB-U353 1 7⁄16“-18 23 25 6.5 54.0 BVIDB-U359GT BVIRB-U359 1 7⁄16“-18 29 32 6.5 50.5
Order No.IP66, black
Order No.IP68, black
ThreadUNEF
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66,schwarz
Bestell-Nr.IP68,schwarz
GewindeUNEF
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP66, black
Order No.IP68, black
ThreadUNEF
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66,schwarz
Bestell-Nr.IP68,schwarz
GewindeUNEF
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• SuitablefortheAMPconnectorseriesCPC• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIRA:IP68 static / IP67 dynamic, conduit side VIDA:IP66 static / IP54 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• PassendzuderAMP-SteckerserieCPC• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIRA:IP68statisch/IP67dynamisch, rohrseitig VIDA: IP66statisch/IP54dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• SuitablefortheSouriauconnectorserieUTG-6/ITTCannonTrident• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIRB:IP68 static / IP67 dynamic, conduit side VIDB:IP66 static / IP54 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2) and conduit seal (NVN3-GT) IP68: Fittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• PassendzuderSouriau-SteckerserieUTG-6/ITTCannonTrident• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• VIRB:IP68statisch/IP67dynamisch, rohrseitig VIDB: IP66statisch/IP54dynamisch, rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
79For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Female Thread Adapters, UNEF/Fine-Metric / Innengewindeadapter, UNEF/Fein-Metrisch PMAFIX
VI UNEF, for MIL C 5015 / UNEF, für MIL C 5015
FI fine-metric / fein-metrisch
•Inmachine,vehicleandtractionbuildingindustries •ImMaschinen-Fahrzeug-undBahnbau
•Inmachineandvehiclebuilding •ImMaschinen-undFahrzeugbau
– BVIVG-U152 5⁄8"-24 12 16 8.0 36.5 – BVIVG-U187 3⁄4"-20 17 20 9.0 46.5 – BVIVG-U210 7⁄8"-20 10 07 9.0 37.0
BVIDG-U212GT BVIVG-U212 7⁄8"-20 12 16 9.0 38.5 BVIDG-U217GT BVIVG-U217 7⁄8"-20 17 20 9.0 46.5 BVIDG-U242GT BVIVG-U242 1"-20 12 16 9.0 40.5
– BVIVG-U243 1"-20 23 25 9.0 55.0 BVIDG-U247GT BVIVG-U247 1"-20 17 20 9.0 47.5
– BVIVG-U292 1 3⁄16"-18 12 16 9.0 40.5 BVIDG-U293GT BVIVG-U293 1 3⁄16"-18 23 25 9.0 55.0 BVIDG-U297GT BVIVG-U297 1 3⁄16"-18 17 20 9.0 47.5
– BVIVG-U299 1 3⁄16"-18 29 29 9.0 47.0 – BVIVG-U352 1 7⁄16"-18 12 16 9.0 39.0
BVIDG-U353GT BVIVG-U353 1 7⁄16"-18 23 25 9.0 52.0 – BVIVG-U356 1 7⁄16"-18 36 40 9.0 63.0
BVIDG-U357GT BVIVG-U357 1 7⁄16"-18 17 20 9.0 46.5 BVIDG-U359GT BVIVG-U359 1 7⁄16"-18 29 29 9.0 52.0 BVIDG-U433GT BVIVG-U433 1 3⁄4"-18 UNS 23 25 10.0 52.0 BVIDG-U436GT BVIVG-U436 1 3⁄4"-18 UNS 36 40 10.0 62.5
– BVIVG-U437 1 3⁄4"-18 UNS 17 20 10.0 46.5 BVIDG-U439GT BVIVG-U439 1 3⁄4"-18 UNS 29 32 10.0 51.5
– BVIVG-U503 2"-18 UNS 23 25 10.0 51.5 BVIDG-U506GT BVIVG-U506 2"-18 UNS 36 40 10.0 62.5
– BVIVG-U508 2"-18 UNS 48 50 10.0 64.5 BVIDG-U509GT BVIVG-U509 2"-18 UNS 29 32 10.0 55.0
– BVIVG-U563 2 1⁄4"-16 UN 23 25 10.0 51.0 BVIDG-U566GT BVIVG-U566 2 1⁄4"-16 UN 36 40 10.0 62.0
– BVIVG-U568 2 1⁄4"-16 UN 48 50 10.0 64.0 BVIDG-U569GT BVIVG-U569 2 1⁄4"-16 UN 29 32 10.0 51.0
– BVIVG-U628 2 1⁄2"-16 UN 48 50 10.0 64.0
TFIL-F08M 8 7 10 6.5 29.5 TFIL-F12M 12 7 10 6.0 56.0 TFIL-F18M 18 7 10 6.0 56.5 TFIL-F30M 30 7 10 6.0 56.5 TFIL-F120 12 10 12 6.0 57.0 TFIL-F180 18 10 12 6.0 57.0 TFIL-F300 30 10 12 6.0 57.0
Order No.IP66, black
Order No.IP68, black
ThreadUNEF
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP66,schwarz
Bestell-Nr.IP68,schwarz
GewindeUNEF
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
Order No.IP67, transparent
Threadfine-metric
Fits to conduit sizeNW metric
Threadlength
Overalllength
Bestell-Nr.IP67,transparent
Gewindefeinmetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VIVG:IP68 static / IP67 dynamic, conduit- and thread side VIDG:IP66 static / IP54 dynamic, conduit- and thread side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Fittingwithpre-assembleduniversalsafetyclips(AFN2), thread seal (OR) IP68GT: Fittingwithpre-assembleduniversalsafetyclips(AFN2)and conduit seal (NVN3-GT); thread seal (O-Ring) IP68: Fittingwithovalclips(OVN2),conduitandthreadseal (NVN3, OR)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• PassendzuRohrprofilfein(T)undgrob(G)• VIVG:IP68statisch/IP67dynamisch, rohr- und gewindeseitig VIDG: IP66statisch/IP54dynamisch, rohr- und gewindeseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: ArmaturmitvormontiertenUniversal-Sicherheitssperren (AFN2),Gewindedichtung(OR) IP68GT: ArmaturmitvormontiertenUniversal-Sicherheitssperren(AFN2) undRohrdichtung(NVN3-GT);Gewindedichtung(OR) IP68: ArmaturmitOval-Sperren(OVN2),Rohr-undGewindedichtung (NVN3,OR)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Lightemittingdiodesarerecognisablethroughtheconnector• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties,freefromhalogensandcamium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• FIL:IP67 static / IP65 dynamic, conduit side• Temperaturerange:–40 °C to +105 °C; Short-term to +120 °C• Contentofdelivery:Fitting with oval clip (OVN2), conduit seal (NFN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• LeuchtdiodensinddurchdasAnschlussgehäuseerkennbar• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften,halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• FIL:IP67statisch/IP65dynamisch,rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+120°C• Lieferumfang:ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NFN3)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 40/41).
IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.40/41).
80 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Y, V, T Pieces / Y-, V-, T-Verteiler
VY Y-Pieces / Y-Verteiler
FV V-Pieces / V-Verteiler
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VYD-100707GT *VYR-100707 10 12 7 10*VYD-121010GT *VYR-121010 12 16 10 12*VYD-171212GT *VYR-171212 17 20 12 16*VYD-231717GT *VYR-231717 23 25 17 20*VYD-292323GT *VYR-292323 29 32 23 25*VYD-362929GT *VYR-362929 36 40 29 32*VYD-483636GT *VYR-483636 48 50 36 40
*FVD-100707GT *FVL-100707 10 12 7 10*FVD-101010GT *FVL-101010 10 12 10 12*FVD-121010GT *FVL-121010 12 16 10 12*FVD-171010GT *FVL-171010 17 20 10 12*FVD-171212GT *FVL-171212 17 20 12 16*FVD-231717GT *FVL-231717 23 25 17 20
Order No.IP66
Order No.IP68
1x conduit sizeNW metric
2x conduit sizesNW metric
Bestell-Nr.IP66
Bestell-Nr.IP68
Eingang passend zu RohrgrösseNW metrisch
Ausgänge passend zu RohrgrösseNW metrisch
Order No.IP66
Order No.IP67
1x conduit sizeNW metric
2x conduit sizesNW metric
Bestell-Nr.IP66
Bestell-Nr.IP67
Eingang passend zu RohrgrösseNW metrisch
Ausgänge passend zu RohrgrösseNW metrisch
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Distributorfittingwithpre-assembleduniversalsafetyclips (AFN2) IP68GT: Distributorfittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT) IP68: Distributorfittingwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: VerteilermitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: VerteilermitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: VerteilermitOval-Sperren(OVN2),Rohrdichtungen(NVN3)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Distributorfittingwithpre-assembleduniversalsafetyclips (AFN2) IP67: Distributorfittingwithovalclips(OVN2),conduitseals(NFN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: VerteilermitvormontiertenUniversal-Sicherheitssperren(AFN2) IP67: VerteilermitOval-Sperren(OVN2),Rohrdichtungen(NFN3)
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
Theinput/outputsizescanbeadaptedwiththeAVD/AVRconduitadapters.DieEin/AusgängekönnenmitdenRohradapternAVD/AVRindividuellangepasstwerden.
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
81For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Y, V, T Pieces / Y-, V-, T-Verteiler PMAFIX
VT T-Pieces / T-Verteiler•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
*VTD-101010GT *VTR-101010 10 12*VTD-121212GT *VTR-121212 12 16*VTD-171717GT *VTR-171717 17 20*VTD-232323GT *VTR-232323 23 25*VTD-292929 GT *VTR-292929 29 32*VTD-363636GT *VTR-363636 36 40*VTD-484848GT *VTR-484848 48 50
Order No.IP66
Order No.IP68
3x conduit sizesNW metric
Bestell-Nr.IP66
Bestell-Nr.IP68
Passend zu RohrgrössenNW metrisch
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66: Distributorfittingwithpre-assembleduniversalsafetyclips (AFN2) IP68GT: Distributorfittingwithpre-assembleduniversalsafetyclips (AFN2) and conduit seal (NVN3-GT) IP68: Distributorfittingwithovalclips(OVN2),conduitseals(NVN3)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66: VerteilermitvormontiertenUniversal-Sicherheitssperren (AFN2) IP68GT: VerteilermitvormontiertenUniversal-Sicherheitssperren (AFN2)undRohrdichtung(NVN3-GT) IP68: VerteilermitOval-Sperren(OVN2),Rohrdichtungen(NVN3)
P68GT available. Please add “GT” after the order no. (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”nachBestellnummerergänzen.(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
82 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Supports / Halter
FH-0 One-piece System Supports / Einteilige Systemhalter
FHS Rails for One-Piece System Supports / Schienen für einteilige Systemhalter
•Inmachinebuildingandinstallationapplications •ImMaschinen-undAnlagebau
•Inmachinebuildingandinstallationapplications •ImMaschinen-undAnlagebau
BFH-07-0 SFH-07-0 7 10 17.0 x 21.5 x 20.0 1 x M4BFH-10-0 SFH-10-0 10 12 20.5 x 24.5 x 20.0 1 x M5BFH-12-0 SFH-12-0 12 16 24.0 x 27.0 x 20.0 1 x M5BFH-17-0 SFH-17-0 17 20 30.0 x 34.0 x 20.0 1 x M6BFH-23-0 SFH-23-0 23 25 38.5 x 42.0 x 20.0 1 x M6BFH-29-0 SFH-29-0 29 32 45.5 x 48.0 x 20.0 1 x M6BFH-36-0 SFH-36-0 36 40 55.5 x 56.0 x 20.0 1 x M6BFH-48-0 SFH-48-0 48 50 67.5 x 68.0 x 20.0 1 x M6
BFHS-00 SFHS-00 BFH-07-48 275.0 25.0 15.5 Additional position supports or distance spacers / ZusätzlichePositions-oderDistanzhalterBFHS-PH SFHS-PH Position support with screws / PositionshaltermitSchraubenBFHS-PH1 SFHS-PH1 Distancespacers/Distanzhalter
Order No.black
Order No.grey
Fits to conduit sizeNW metric
DimensionsWidth x Height x Depth
FixingScrew
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW metrisch
DimensionenBreite x Höhe x Tiefe
Befestigungs-schrauben
Order No.black
Order No.grey
Fits to PMACLIP
DimensionsLength
DimensionsWidth
DimensionsHeight
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu PMACLIP
Dimensionen Länge
Dimensionen Breite
Dimensionen Höhe
• High-grade,speciallyformulatedpolyamide6• One-piececonstruction• Veryhighimpactresistance• Optimalaxialstrainreliefduetointegratedrib• Suitableforoverheadinstallationsduetosafetylid• Highretentionforces• Quickmountingduetosingleholefixing• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoards(G)• FitstorailforsystemsupportsFHS• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C
• Hochwertiges,speziellformuliertesPolyamid6• EinteiligeBauweise• HervorragendeSchlagfestigkeit• OptimaleaxialeZugentlastungdurchintegrierteRippe• GeeignetfürÜberkopf-InstallationdurchSicherungsbügel• HoheHaltekräfte• SchnelleMontagedurchEinlochbefestigung• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• PassendzuSystemhalter-SchieneFHS• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C
• High-grade,glassfibrereinforcedpolyamide6• Self-extinguishing,• Freefromhalogensandcadmium• Excellentimpactstrength• VeryHighstiffness• Extremelysolid• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery:BFHS-00:Rail,2positionsupportswithscrews
• Hochwertiges,glasfaserverstärktesPolyamid6• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• SehrhoheSteifigkeit• Extremstabil• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:BFHS-00:Schiene,2PositionshaltermitSchrauben
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
83For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Supports / Halter PMAFIX
VH System Supports / Systemhalter•Inmachinebuildingandinstallationapplications •ImMaschinen-undAnlagebau
*VH-17-010 *VH-17-020 *VH-17-000 17 20 35 x 36 x 36 6 x M5*VH-23-010 *VH-23-020 *VH-23-000 23 25 35 x 44 x 36 6 x M5*VH-29-010 *VH-29-020 *VH-29-000 29 32 46 x 52 x 40 6 x M5*VH-36-010 *VH-36-020 *VH-36-000 36 40 53 x 58 x 60 6 x M5*VH-48-010 *VH-48-020 *VH-48-000 48 50 66 x 72 x 60 6 x M5
Order No.Support
Order No.Clip
Order No.Complete
Fits to conduit sizeNW metric
DimensionsWidth x Height x Depth
FixingScrew
Bestell-Nr.Halter
Bestell-Nr.Bügel
Bestell-Nr.Komplett
Passend zu RohrgrösseNW metrisch
DimensionenBreite x Höhe x Tiefe
Befestigungs-schrauben
• High-gradeformulatedpolyamide• Variableassemblyduetosixholefastening• Completelysafeagainstturning/movements• Optimalstrainreliefduetointegratedrib• Maximumsecuritywiththesafetyclip• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C
• HochwertigformuliertesPolyamid• VariableMontagedankSechs-Loch-Befestigung• Absolutverdrehsicher• OptimaleZugentlastungdankintegrierterRippe• GrössteSicherheitmitzusätzlichenSicherungsbügeln• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C
Dimensions / Dimensionen in mm
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
84 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Supports / Halter
GPS One-piece heavy System Supports / Einteilige schwere Systemhalter
GP System Supports for Stacking / Stapelbare Systemhalter
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
BGPS-17 17 20 2 70.0 51.0 30.0 BGPS-23 23 25 2 70.0 51.0 30.0 BGPS-29 29 32 3 85.0 65.0 30.0 BGPS-36 36 40 3 85.0 65.0 30.0BGPS-48 48 50 4 115.0 92.5 30.0 BGPS-56 56 – 4 115.0 92.5 30.0
*GP-16T *GP-16G 17 20 47.5 66.0 36.0 *GP-21T *GP-21G 23 25 47.5 66.0 36.0 *GP-29T *GP-29G 29 32 61.5 66.0 36.0 *GP-36T *GP-36G 36 40 61.5 66.0 36.0 *GP-48T *GP-48G 48 50 76.0 66.0 36.0
– *GP-56G 56 – 87.0 78.0 36.0
Order No. Fits to conduit sizeNW metric DIN-NW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr. Passend zu RohrgrösseNW metrisch DIN-NW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
Order No.fine profile
Order No.coarse profile
Fits to conduit sizeNW metric
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.Feinprofil
Bestell-Nr.Grobprofil
Passend zu RohrgrösseNW metrisch
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
• High-grade,speciallyformulatedpolyamide6• One-piececonstruction,stackable• Excellentimpactresistance• Heavydesign,highretentionforces• ApplicablewithstandardmetalCrails• Easypre-installationbyconduitsnap-in• Claspforeasypre-mountingandfinalassembly• Verygoodchemicalporperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Thefollowingnominalwidthscanbecombinedforstacking: NW 17 with NW 23, NW 29 with NW 36, NW 48 with NW 56• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery:System support and 2 pcs screws for securing of the lid (optional); without mounting accessories
• Hochwertiges,speziellformuliertesPolyamid6• EinteiligeBauweise,stapelbar• HervorragendeSchlagfestigkeit• SchwereAusführung,hoheHaltekräfte• VerwendbarmitStandardMetallC-Schienen• EinfacheVorinstallationdurchEinschnappendesRohres• SchnappverschlussfüreinfachsteVor-undEndmontage• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• FolgendeNennweitensinduntereinanderstapelbar: NW17mitNW23,NW29mitNW36,NW48mitNW56• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:Systemhalterund2Stk.SchraubenzurFixierungdes Schnappverschlusses(optional);ohneweiteresMontagezubehör
• High-grade,speciallyformulatedpolyamide6• Variablestackingpossibilities,duetothe“block”-systemahigh rigidity is guaranteed• Strainreliefduetogrippingaroundconduit• Especiallysuitablefordynamicapplicationsduetoroundededges• Varietyofsupportpossibilities• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery:System support with assembling screws; without mounting accessories
• Hochwertiges,speziellformuliertesPolyamid6• BeliebigeStapelvariantenmöglichmithoher“Block”-Steifigkeit• ZugentlastungmitFixierungsrippen• DankabgerundetenKantenspeziellfürdynamischeVerlegunggeeignet• VerschiedeneBefestigungsmöglichkeiten• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:SystemhaltermitVerbindungsschrauben; ohne Befestigungszubehör
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
85For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Supports / Halter PMAFIX
SGB Tube Clamps / Rohrschellen•Especiallysuitableforthemountingofstaticconduits •GeeignetzurBefestigungvonstatischverlegtenLeitungen
SGB-07 7 10 13.0 1 x M4SGB-09 10 12 13.0 1 x M4SGB-11 12 16 13.0 1 x M4SGB-16 17 20 16.0 1 x M5SGB-21 23 25 16.0 1 x M5SGB-29 29 32 19.0 1 x M6SGB-36 36 40 19.0 1 x M6SGB-48 48 50 19.0 1 x M6
Order No. Fits to conduit sizeNW metric
DimensionsWidth
FixingScrew
Bestell-Nr. Passend zu Rohrgrösse NW metrisch
DimensionenBreite
Befestigungs-schrauben
• GalvanizedsteelaccordingtoDIN3016• Elastomerfreefromhalogens(EPDM)• Forthemountingofstaticconduits• SmoothconnectiontoPMAFLEXcorrugatedconduits• Goodozoneandageingresistance• Temperaturerange: –40 °C to +120 °C
• GalvanischverzinkterStahlnachDIN3016• HalogenfreiesElastomerprofil(EPDM)• ZurBefestigungstatischverlegterRohre• SaubereVerbindungmitPMAFLEX-Wellrohren• GuteOzon-undAlterungsbeständigkeit• Temperaturbereich:–40°Cbis+120°C
Dimensions / Dimensionen in mm
GN Half Shells / Halbschalen•UsedforfixingPMAconduitsinconjunctionwithbeam systems, particularly in traction and machine applications
•ZurBefestigungderPMA-SchutzrohreinVerbindungmit SystemblöckenvorallemimSchienenfahrzeug-und Maschinenbau
BGN-S12T – 12 16 26.5 34.0 BGN-S17T BGN-S17G 17 20 32.0 34.0 BGN-S23T BGN-S23G 23 25 39.5 34.0 BGN-S29T BGN-S29G 29 32 47.0 34.0 BGN-S36T – 36 40 55.0 36.5
– BGN-S36G 36 40 55.0 34.0 BGN-S48T – 48 50 66.5 36.5
– BGN-S48G 48 50 66.5 34.0 – BGN-S70G 70 80 93.5 38.0
Order No.fine profile, black
Order No.coarse profile, black
Fits to conduit sizeNW metric
OutsideDiameter
DimensionsWidth
Bestell-Nr.Feinprofil,schwarz
Bestell-Nr.Grobprofil,schwarz
Passend zu Rohrgrösse NW metrisch
Aussen-Durchmesser
DimensionenBreite
• High-grade,speciallyformulatedpolyamide6• Variablecombinations• Strainreliefduetogrippingaroundconduit• Especiallysuitablefordynamicapplicationsduetoroundededges• Varietyofsupportpossibilities• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C
• Hochwertiges,speziellformuliertesPolyamid6• SehrvariableKombinationsmöglichkeitenmitSystemblöcken• ZugentlastungmitFixierungsrippen• DankabgerundetenKantenspeziellfürdynamischeAnwendungengeeignet• VerschiedeneBefestigungsmöglichkeiten• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;Kurzzeitig:+160°C
Dimensions / Dimensionen in mm
86 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMAFIX Supports / Halter
GL Tube Clamps / Rohrschellen
GH Tube Clamps / Rohrschellen
•Usedingeneralmachineandinstallationapplications •FürdenallgemeinenMaschinen-undAnlagebau
•Usedingeneralmachineandinstallationapplications •FürdenallgemeinenMaschinen-undAnlagebau
BGL-07 SGL-07 07 10 25.0 1 x M4BGL-10 SGL-10 10 12 27.0 1 x M4BGL-12 SGL-12 12 16 31.0 1 x M4BGL-17 SGL-17 17 20 39.5 1 x M5BGL-23 SGL-23 23 25 49.0 1 x M5BGL-29 SGL-29 29 32 57.0 1 x M6
Order No.black
Order No.grey
Fits to conduit sizeNW metric
DimensionsWidth
FixingScrew
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW metrisch
DimensionenBreite
Befestigungs-schrauben
Order No.black
Order No.grey
Fits to conduit sizeNW metric
DimensionsWidth
FixingScrew
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW metrisch
DimensionenBreite
Befestigungs-schrauben
• High-grade,speciallyformulatedpolyamide6• Self-extinguishing• Freefromhalogensandcadmium• Temperaturerange: –40 °C to +105 °C
• Hochwertiges,speziellformuliertesPolyamid6• Selbstverlöschend• Halogen-undcadmiumfrei• Temperaturbereich: –40 °C bis +105 °C
• High-grade,speciallyformulatedpolyamide6• Self-extinguishing• Freefromhalogensandcadmium• Nominalwidths:23-95• Temperaturerange: –40 °C to +105 °C
• Hochwertiges,speziellformuliertesPolyamid6• Selbstverlöschend• Halogen-undcadmiumfrei• Nennweiten:23-95• Temperaturbereich: –40 °C bis +105 °C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
BGH-23 SGH-23 23 25 16.0 2 x M5BGH-29 SGH-29 29 32 19.0 2 x M6BGH-36 SGH-36 36 40 24.0 2 x M6BGH-48 SGH-48 48 50 24.0 2 x M6BGH-56 SGH-56 56 63 26.0 2 x M8BGH-70 SGH-70 70 80 30.0 2 x M8BGH-95 SGH-95 95 106 30.0 2 x M8
87For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Large Sizes / Extra Gross
Connectors / Anschlüsse PMAGRIP
GGV Flange, straight / Anschlussflansch, gerade
GOV Flange, 90° elbow / Anschlussflansch, 90° Winkel
•Inrailwayvehicleconstructionaswellasinawiderange of industrial applications with high sealing and safety requirements
•ImSchienenfahrzeugbauundweiterenindustriellen AnwendungsgebietenmithohenSicherheits-und Dichtheitsanforderungen
•Inrailwayvehicleconstructionaswellasinawiderange of industrial applications with high sealing and safety requirements
•ImSchienenfahrzeugbauundweiterenindustriellen AnwendungsgebietenmithohenSicherheits-und Dichtheitsanforderungen
BGGV-56 56 82.0 97.0 42.0 BGGV-70 70 97.0 114.0 48.0 BGGV-95 95 126.0 146.0 53.0
BGOV-56 56 82.0 97.0 101.0 BGOV-70 70 97.0 114.0 115.0 BGOV-95 95 126.0 146.0 149.0
Order No.black
Fits to conduit sizeNW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Passend zu RohrgrösseNW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
Order No.black
Fits to conduit sizeNW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Passend zu RohrgrösseNW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
• High-grade,speciallyformulatedpolyamide6• FlangesealFGO4madefromEPDM• FlangesealFGO4/01madefromNBRonrequest• Veryhighimpactstrength• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP68,IP69KwithconduitsealingNVN3• Verygoodchemicalproperties• Freefromhalogensandcadmium• TemperaturerangewithFG04: –40 °C to +105 °C• TemperaturerangewithFG04/01: –25 °C to +70 °C• Contentofdelivery:Flangepart,fixationclamps(including2screws), conduitseal(NVN3),flangeseal(FGO4orFGO4/01)• Iftheapplicationtemperatureisabove70°Cwerecommendtousean additional internal conduit support sleeve (BES)
• Hochwertiges,speziellformuliertesPolyamid6• FlanschdichtungFGO4ausEPDM• FlanschdichtungFG4/01ausNBRaufAnfrage• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• Dichtheit:IP68,IP69KmitRohrdichtungNVN3• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• TemperaturbereichmitFG04: –40 °C bis +105 °C ; • TemperaturbereichmitFG04/01:–25°Cbis+70°C;• Lieferumfang:Flanschteil,Fixierungsschellen(inkl.2Schrauben), Rohrdichtung(NVN3),Flanschdichtung(FGO4oderFGO4/01)• BeiEinsatzüber70°Cempfehlenwir,zusätzlicheinenStützring(BES) einzusetzen.
• High-grade,speciallyformulatedpolyamide6• FlangesealFGO4madefromEPDM• FlangesealFGO4/01madefromNBRonrequest• Veryhighimpactstrength• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP68,IP69KwithconduitsealingNVN3• Verygoodchemicalproperties• Freefromhalogensandcadmium• TemperaturerangewithFG04: –40 °C to +105 °C• TemperaturerangewithFG04/01: –25 °C to +70 °C• Contentofdelivery:Flangepart,fixationclamps(including2screws), conduitseal(NVN3),flangeseal(FGO4orFGO4/01)• Iftheapplicationtemperatureisabove70°Cwerecommendtousean additional internal conduit support sleeve (BES)
• Hochwertiges,speziellformuliertesPolyamid6• FlanschdichtungFGO4ausEPDM• FlanschdichtungFG4/01ausNBRaufAnfrage• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• Dichtheit:IP68,IP69KmitRohrdichtungNVN3• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• TemperaturbereichmitFG04: –40 °C bis +105 °C ; • TemperaturbereichmitFG04/01:–25°Cbis+70°C;• Lieferumfang:Flanschteil,Fixierungsschellen(inkl.2Schrauben), Rohrdichtung(NVN3),Flanschdichtung(FGO4oderFGO4/01)• BeiEinsatzüber70°Cempfehlenwir,zusätzlicheinenStützring(BES) einzusetzen.
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
88 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Large Sizes / Extra Gross
PMAGRIP Connectors / Anschlüsse
GG Flange, straight / Anschlussflansch, gerade
GO Flange, 90° elbow / Anschlussflansch, 90° Winkel
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
BGG-56 SGG-56 56 82.0 97.0 42.0 BGG-70 SGG-70 70 97.0 114.0 48.0 BGG-95 SGG-95 95 126.0 146.0 53.0
BGG-125 SGG-125 125 – 194.0 79.0
BGO-56 SGO-56 56 82.0 97.0 101.0 BGO-70 SGO-70 70 97.0 114.0 115.0 BGO-95 SGO-95 95 126.0 146.0 149.0
Order No.black
Order No.grey
Fits to conduit sizeNW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
Order No.black
Order No.grey
Fits to conduit sizeNW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
• High-grade,speciallyformulatedpolyamide6• FlangesealFGO4madefromEPDM• FlangesealFGO4/01madefromNBR• Veryhighimpactstrength• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP50withoutseal,IP65withconduitseal)• Verygoodchemicalproperties• Freefromhalogensandcadmium• TemperaturerangewithFG04: –40 °C to +105 °C• TemperaturerangewithFG04/01: –25 °C to +70 °C• Contentofdelivery:Flangepart,fixationclamps(incl.2screws), flangeseal(FGO4orFGO4/01),conduitsealring(SGO3,optionalforIP65)
• Hochwertiges,speziellformuliertesPolyamid6• FlanschdichtungFGO4ausEPDM• FlanschdichtungFG4/01ausNBR• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• Dichtheit:IP50ohneDichtung,IP65mitRohrdichtung)• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• TemperaturbereichmitFG04: –40 °C bis +105 °C ; • TemperaturbereichmitFG04/01:–25°Cbis+70°C;• Lieferumfang:Flanschteil,Fixierungsschellen(inkl.2Schrauben), Flanschdichtung(FGO4oderFGO4/01),Rohrdicht-Ring(SGO3,optional fürIP65)
• High-grade,speciallyformulatedpolyamide6• FlangesealFGO4madefromEPDM• FlangesealFGO4/01madefromNBR• Veryhighimpactstrength• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP50(IP65withconduitsealring)• Verygoodchemicalproperties• Freefromhalogensandcadmium• TemperaturerangewithFG04: –40 °C to +105 °C• TemperaturerangewithFG04/01: –25 °C to +70 °C• Contentofdelivery:Flangepart,fixationclamps(incl.2screws),flange seal (FGO4 or FGO4/01), conduit seal ring (SGO3, optional for IP65)
• Hochwertiges,speziellformuliertesPolyamid6• FlanschdichtungFGO4ausEPDM• FlanschdichtungFG4/01ausNBR• HervorragendeSchlagfestigkeit• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausresisskräfte• Dichtheit:IP50(IP65mitRohr-Dichtring)• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• TemperaturbereichmitFG04: –40 °C bis +105 °C ; • TemperaturbereichmitFG04/01:–25°Cbis+70°C;• Lieferumfang:Flanschteil,Fixierungsschellen(inkl.2Schrauben), Flanschdichtung(FGO4oderFGO4/01),Rohrdicht-Ring(SGO3,optionalfür IP65)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
89For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Large Sizes / Extra Gross
Connectors / Anschlüsse PMAGRIP
GG straight, male thread / gerade mit Aussengewinde
GI straight, female thread / gerade mit Innengewinde
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
•Forcableprotectionsystemsinawiderangeofapplications •FürKabelschutzineinembreitenAnwendungsgebiet
BGG-M6356 SGG-M6356 M63x1.5 56 18.0 98.0 57.5 BGG-P3656 SGG-P3656 PG 36 56 18.0 98.0 57.3
BGI-M7556 SGI-M7556 M75x1.5 56 15.0 98.0 53.3
Order No.black
Order No.grey
Thread Fits toNW
ThreadLength
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Bestell-Nr.grau
Gewinde passend zuNW
Gewinde- länge
DimensionenHöhe
DimensionenTiefe
Order No.black
Order No.grey
Thread Fits toNW
ThreadLength
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Bestell-Nr.grau
Gewinde passend zuNW
Gewinde- länge
DimensionenHöhe
DimensionenTiefe
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Easymountingwithlockingclamps• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP50 (IP65 when using enclosed conduit seal)• Verygoodchemicalproperties• Freefromhalogensandcadmium• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery:threadedconnectorbody,fixationclamps (incl. 2 screws), conduit seal ring (SGO3, optional for IP65)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• EinfacheMontagemitKlemmbacken• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• Dichtheit:IP50(IP65mitmitgelieferterRohrdichtung)• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• Temperaturbereich:–50°Cbis+105°C;kurzzeitig:+160°C• Lieferumfang: Anschlussteil mit Gewinde, Fixierungsschellen (inkl.2Schrauben),Rohrdicht-Ring(SGO3,optionalfürIP65)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• Easymountingwithlockingclamps• Vibration-proofconnectiontoPMAFLEXconduits• Highconduitpull-outstrength• Ingressprotection:IP50 (IP65 on conduit side with enclosed conduit seal ring)• Verygoodchemicalproperties• Freefromhalogensandcadmium• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Contentofdelivery:threadedconnectorbody,fixationclamps (incl. 2 screws), conduit seal ring (SGO3, optional for IP65)
• Hochwertiges,speziellformuliertesPolyamid6• HervorragendeSchlagfestigkeit• EinfacheMontagemitKlemmbacken• VibrationssichereVerbindungzuPMAFLEX-Schutzrohren• HoheWellrohr-Ausreisskräfte• DichtheitIP50(IP65rohrseitigbeiVerwendungdesmitgelieferten Rohr-Dichtrings)• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• Temperaturbereich:–50°Cbis+105°C;kurzzeitig:+160°C• Lieferumfang: Anschlussteil mit Gewinde, Fixierungsschellen (inkl.2Schrauben),Rohrdicht-Ring(SGO3,optionalfürIP65)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
90 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Large Sizes / Extra Gross
PMAGRIP Conduits / Wellrohre
Jumbo Conduits / Wellrohre
Dimensions / Dimensionen in mm
PCLG-56B PCLG-56S 56 68 56.3 67.2 130 / – 30PCLG-70B PCLG-70S 70 80 67.5 80.0 160 / – 10PCLG-95B PCLG-95S 95 106 91.5 106.0 210 / – 10PCLG-125B PCLG-125S 125 146 126.5 146.5 450 / – 6
PIHG-56B PIHG-56S 56 68 56.3 67.2 110 / 270 30PIHG-70B PIHG-70S 70 80 67.2 79.6 150 / 350 30PIHG-95B PIHG-95S 95 106 91.3 106.0 170 / 450 30 PIHG-125B PIHG-125S 125 146 126.5 146.5 350 / 4 80 20
VOHG-56B VOHG-56S 56 68 55.5 67.2 135 / – 30VOHG-70B VOHG-70S 70 80 67.0 80.0 200 / – 10VOHG-95B VOHG-95S 95 106 90.5 106.0 300 / – 10VOHG-125B VOHG-125S 125 146 126.0 146.5 480 / – 6
VCSG-56B VCSG-56S 56 68 56.1 67.2 150 / – 30VCSG-70B VCSG-70S 70 80 66.5 80.0 200 / – 10VCSG-95B VCSG-95S 95 106 91.0 106.0 300 / – 10
PCSG-56B PCSG-56S 56 68 56.1 67.2 130 / 280 30PCSG-70B PCSG-70S 70 80 66.5 80.0 170 / 360 10PCSG-95B PCSG-95S 95 106 91.0 106.0 250 / 470 10
PUEG-56B – 56 68 56.3 67.2 90 / 170 30PUEG-70B – 70 80 68.2 80.2 100 / 220 30
CYLG-56B CYLG-56S 56 68 56.3 67.2 120 / – 30CYLG-70B CYLG-70S 70 80 68.0 80.0 160 / – 10CYLG-90B CYLG-95S 95 106 91.9 106.0 210 / – 10CYLG-125B CYLG-125S 125 146 126.5 146.5 450 / – 6
Order No.black
Order No.grey
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.**/dyn.*** Radius
PU meter
Bestell-Nr.schwarz
Bestell-Nr.grau
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchm.
Aussen-Durchm.
stat.**/dyn.***Radius
VEMeter
For further conduits and other sizes Weitere Wellrohre und andere Grössen finden Sie see conduit guide. in der Wellrohrübersicht.
91For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Large Sizes / Extra Gross
Accessories / Zubehör PMAGRIP
GH Tube Clamps / Rohrschellen•Formountingconduitsinawiderangeofapplications •ZurRohrbefestigungineinembreitenAnwendungsgebiet
BGH-56 SGH-56 56 63 26.0 2 x M8BGH-70 SGH-70 70 80 30.0 2 x M8BGH-95 SGH-95 95 106 30.0 2 x M8
Order No.black
Order No.grey
Fits to conduit sizeNW metric
DimensionsWidth
FixingScrew
Bestell-Nr.schwarz
Bestell-Nr.grau
Passend zu RohrgrösseNW metrisch
DimensionenBreite
Befestigungs-schrauben
• High-grade,speciallyformulatedpolyamide6• One-piecedesign• Integratedribprovidesaxialstrainrelief• Allowsturningoftheconduitthusavoidingtorsionstresses• Pre-fixationontheconduitpossible• Allowssolidfixationwithtwoscrews• Self-extinguishing• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Nocorrosion• Temperaturerange: –40 °C to +105 °C
• Hochwertiges,speziellformuliertesPolyamid6• Einteilig• AxialeZugentlastungdurchintegrierteRippe• DurchVerdrehbarkeitdesRohreskannTorsionsbelastung vermieden werden• VorfixierungamRohrmöglich• StabileBefestigungdurchzweiSchrauben• Selbstverlöschend• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)undgrob(G)• KeineKorrosion• Temperaturbereich: –40 °C bis +105 °C
Dimensions / Dimensionen in mm
SGS Tube Clamps / Rohrschellen
SG03 Conduit Seal Rings / Rohrdichtringe
•Formountingofstaticconduits •ZurBefestigungstatischverlegterRohre
•UsedattheconduitendforsealingbetweenthePMAGRIP flangesGG/GI/GOandPMAFLEXJumboconduits
•EingesetztumrohrseitigzwischenPMAGRIP-Flanschen GG/GI/GOundPMAFLEXJumbo-Wellrohrenabzudichten
SGS-36 36 80.0 48.0 19.0SGS-48 48 94.0 58.0 19.0 SGS-56 56 118.0 72.0 24.0 SGS-70 70 130.0 85.0 24.0 SGS-95 95 156.0 110.0 24.0
SGS-125 125 200.0 152.0 24.0
SGO3-56 56 49.5 61.0 1.5 SGO3-70 70 61.5 74.0 1.5 SGO3-95 95 86.0 102.0 1.5
SGO3-125 125 122.0 142.0 2.0
Order No.black
Fits to conduit sizeNW
DimensionsWidth
DimensionsHeight
DimensionsDepth
Bestell-Nr.schwarz
Passend zu RohrgrösseNW
DimensionenBreite
DimensionenHöhe
DimensionenTiefe
Order No.black
Fits to conduit sizeNW
InsideDiameter
OutsideDiameter
DimensionsWidth
Bestell-Nr.schwarz
Passend zu RohrgrösseNW
Innen-Durchmesser
Aussen-Durchmesser
DimensionenBreite
• Galvanizedsteel• Elastomerprofile(EPDM),Elastomerprofile,freefromhalogens• SmoothconnectiontoPMAFLEXcorrugatedconduits• Goodozoneandageingresistance• Temperaturerange: –40 °C to +120 °C
• GalvanischverzinkterStahl• Elastomerprofil(EPDM),halogenfreiesElastomerprofil• SaubereVerbindungmitPMAFLEX-Wellrohren• GuteOzon-undAlterungsbeständigkeit• Temperaturbereich:–40°Cbis+120°C
• Nitrilerubber• Temperaturerange: –40 °C to +105 °C
• Nitril-Kautschuk• Temperaturbereich: –40 °C bis +105 °C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
ForothersizesofBGH/SGHtubeclampspleaseseepage86/FürandereGrössenderBHG/SGHRohrschellensieheSeite86
92 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Divisible System / Teilbares System
PMA Divisible System Connectors / Anschlüsse
LNO divisible, straight, metric / teilbar, gerade, metrisch
LN Divisible Lock Nuts, metric / Teilbare Gegenmutter, metrisch
•CompatiblewithPMAstandard,slitanddivisibleconduitswith standard nominal widths•Inindustries,plantconstruction,machinebuildingaswellasin house and electrical installations•Forretrofitinstallationorrepair
•PassendzuPMAStandard-Wellrohrensowiegeschlitztenund teilbarenPMA-WellrohrenmitStandard-Nennweiten•InderIndustrie,imAnlagen-undMaschinenbausowiebei Haus-undElektroinstallationen•ZurNachrüstungoderReparatur
•CompatiblewithPMAdivisiblesystem,typeBLNO•InconnectionwithdivisiblePMAconnectorsandconduits•Forinstallationuponfullyassembledcableloomsorrepairin machine and plant construction
•PassendzuteilbaremPMA-System,TypBLNO•InVerbindungmitteilbarenPMA-Verschraubungenund -Wellrohren•ZurNachinstallationoderReparaturimMaschinen-und Anlagebau
BLNO-M160 M16x1.5 12 16 13.0 36.5 BLNO-M162 M16x1.5 12 16 13.0 39.5 BLNO-M202 M20x1.5 12 16 13.0 39.5 BLNO-M207 M20x1.5 17 20 13.0 43.5 BLNO-M257 M25x1.5 17 20 14.0 44.5 BLNO-M253 M25x1.5 23 25 14.0 52.5 BLNO-M323 M32x1.5 23 25 17.0 56.0 BLNO-M329 M32x1.5 29 32 17.0 61.0 BLNO-M409 M40x1.5 29 32 21.0 65.0 BLNO-M406 M40x1.5 36 40 22.0 74.5 BLNO-M508 M50x1.5 48 50 22.0 80.5
BLN-M16 M16x1.5 BLNO-M160 BLNO-M162 21.5 8.0 BLN-M20 M20x1.5 BLNO-M202 BLNO-M207 29.0 8.0 BLN-M25 M25x1.5 BLNO-M257 BLNO-M253 35.5 9.0 BLN-M32 M32x1.5 BLNO-M323 BLNO-M329 44.5 12.0 BLN-M40 M40x1.5 BLNO-M409 BLNO-M406 53.5 15.0 BLN-M50 M50x1.5 BLNO-M508 69.5 15.0
Order No. IP54black
Threadmetric
Fits to conduit sizeNW metric
Thread length
Overalllength
Bestell-Nr. IP54schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde-länge
Gesamt-länge
Order No.black
Threadmetric
Fits withDivisible Connector
OutsideDiameter
DimensionsWidth
Bestell-Nr. schwarz
Gewindemetrisch
Passend zu teilbaren Verschraubung
Aussen-Durchmesser
DimensionenBreite
• Speciallymodifiedpolyamide6• IP54 –One-piecedivisiblefitting• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange:–50°Cto+105°C;Short-term:+160°C• Special:Push-ininstallationofconduitintopre-installedfitting also possible• Delivery:fittingdeliveredopen
• SpeziellmodifiziertesPolyamid6• IP54 einteilige, teilbare Anschlussarmatur • Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich:–50°Cbis+105°C;kurzzeitig:+160°C• Besonderheit:auch Einstoss-Montage des Rohres in vorinstallierten Fitting möglich• Lieferung:Anschlussarmaturwirdoffengeliefert
• High-grade,speciallyformulatedpolyamide6• Highimpactresistance• Easyinstallation• Verygoodchemicalproperties• Freefromhalogensandcadmium• Temperaturerange:–40°Cto+100°C;Short-term:+130°C
• Hochwertiges,speziellformuliertesPolyamid6• SehrguteSchlagfestigkeit• EinfacheMontage• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• Temperaturbereich:–40°Cbis+100°C;kurzzeitig:+130°C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
NEW /
NEU
NEW /
NEU
patent / patentiert
Note: ForsuitableOne-piece System Supports, see page 82
Hinweis: Für passende einteilige Systemhalter,sieheSeite82
93For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Divisible System / Teilbares System
Conduits / Wellrohre PMA Divisible System
min.PACOF-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• Speciallymodifiedpolyamide6• Easyinstallationandtrouble-freeretrofitting,applicablealsoforrepairs• Canbeopenedandclosedagaininlongitudinaldirectionanytime• Self-extinguishing• Freefromhalogensandcadmium• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Chemicalresistance: To fuels, mineral oils, fats, alkalies, weak acids etc.
• SpeziellmodifiziertesPolyamid6• EinfachsteInstallation,problemloseNachinstallation,geeignetzu Reparaturzwecken• LässtsichinLängsrichtungjederzeitöffnenundwiederschliessen• Selbstverlöschend• Halogen-undcadmiumfrei• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• ChemischeBeständigkeit: Gegen Kraftstoffe, Mineralöle, Fette,Alkalien,schwacheSäurenu.a.
min.PPCOF-Index
max.
ductility
fatigue reversed bending
compression resistance
low temperature performance
weathering resistance
Biegbarkeit
Dauer- / Biegewechselfestigkeit
Druck- / Trittfestigkeit
Kälteeigenschaften
Witterungseigenschaften
• SpeciallymodifiedpolypropylenePP• Easyinstallationandtrouble-freeretrofitting,applicablealsoforrepairs• Canbeopenedandclosedagaininlongitudinaldirectionanytime• Temperaturerange: –20 °C to +105 °C; Short-term to +150 °C• Chemicalresistance: To fuels, fats, alkalies, acids etc.
• SpeziellmodifiziertesPolypropylenPP• EinfachsteInstallation,problemloseNachinstallation, geeignet zu Reparaturzwecken• LässtsichinLängsrichtungjederzeitöffnenundwiederschliessen• Temperaturbereich:–20°Cbis+105°C;Kurzzeitigbis+150°C• Chemische Beständigkeit:GegenKraftstoffe,Fette,Alkalien,Säurenu.a..
NEW / NEU
NEW / NEU
FineprofileT/FeinprofilT Tight bending radiusEnge Biegeradien
** stat. R = lowest recommended bending radius forstatic(fixed)installation.
** stat. R = kleinster empfohlener Biegeradius für statische(feste)Verlegung.
CoarseprofileG/GrobprofilGHigh pull-out strengthHoheAusreisskräfte
PACOF flexible, divisible / flexibel, teilbar•Inmachinebuildingandplantconstruction •ImMaschinen-undAnlagenbau
PPCOF flexible, divisible / flexibel, teilbar•Inmachinebuildingandplantconstruction •ImMaschinen-undAnlagenbau
PACOF-07B 07 10 5.6 10.0 30 50PACOF-10B 10 12 8.5 12.8 33 50PACOF-12B 12 16 11.0 15.6 35 50PACOF-14B - - 13.0 19.0 42 50PACOF-17B 17 20 15.5 21.1 45 50PACOF-20B - - 19.1 25.5 55 50PACOF-23B 23 25 22.1 28.4 70 50PACOF-26B - - 24.0 31.6 80 50PACOF-29B 29 32 27.2 34.5 120 50PACOF-36B 36 40 32.0 42.4 145 30PACOF-48B 48 50 43.9 54.1 150 30PACOF-70B 70 80 62.0 79.0 190 10
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Dimensions / Dimensionen in mm
PPCOF-07B 07 10 5.9 10.0 25 50PPCOF-10B 10 12 8.5 12.8 28 50PPCOF-12B 12 16 11.0 15.6 35 50PPCOF-14B - - 13.0 19.0 40 50PPCOF-17B 17 20 15.1 21.1 45 50PPCOF-20B - - 19.6 25.5 55 50PPCOF-23B 23 25 22.1 28.4 60 50PPCOF-26B - - 24.0 31.6 65 50PPCOF-29B 29 32 26.6 34.5 100 50PPCOF-36B 36 40 31.8 42.4 120 30PPCOF-48B 48 50 43.9 54.1 140 30PPCOF-70B 7 80 60.5 78.0 200 10
Order No.black
Conduit size NW
Conduit sizemetric
Inside Diameter
Outside Diameter
stat.** Radius
PU meter
Bestell-Nr.schwarz
RohrgrösseNW
Rohrgrössemetrisch
Innen-Durchmesser
Aussen-Durchmesser
stat.**Radius
VEMeter
Dimensions / Dimensionen in mm
94 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Swivel Connectors / Drehbare Armaturen
SB 90° curved elbow, metric, metal, swivel 90° Bogenwinkel, metrisch, Metall, drehbar
SB 90° curved elbow, PG, metal, swivel 90° Bogenwinkel, PG, Metall, drehbar
•Forapplicationswithhightechnicalrequirements mainly in machine building•Suitableforoccasionalrotation
•FürAnwendungenmiterhöhtentechnischenAnforderungen hauptsächlich im Maschinenbau•GeeignetfürgelegentlicheDrehbewegung
•Forapplicationswithhightechnicalrequirements mainly in machine building•Suitableforoccasionalrotation
•FürAnwendungenmiterhöhtentechnischenAnforderungen hauptsächlich im Maschinenbau•GeeignetfürgelegentlicheDrehbewegung
NSBV-M207-10 M20x1.5 17 20 10.0 62.5 x 74.5 NSBV-M253-11 M25x1.5 23 25 11.0 73.0 x 87.5 NSBV-M329-13 M32x1.5 29 32 13.0 86.5 x 98.0 NSBV-M406-13 M40x1.5 36 40 13.0 98.5 x 127.5NSBV-M409-13 M40x1.5 29 32 13.0 86.5 x 98.0 NSBV-M508-14 M50x1.5 48 50 14.0 113.0 x 139.0 NSBV-M638-14 M63x1.5 48 50 14.0 110.0 x 139.0
NSBV-P167-6.5 16 17 20 6.5 58.0 x 75.5 NSBV-P213-7 21 23 25 7.0 69.0 x 87.5 NSBV-P299-8 29 29 32 8.0 80.0 x 98.0 NSBV-P366-9 36 36 40 9.0 91.5 x 127.5 NSBV-P488-10 48 48 50 10.0 106.0 x 139.0
Order No. IP68 black
Threadmetric
Fits to conduit sizeNW metric
Threadlength
External dimensions
Bestell-Nr.IP68schwarz
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
Order No. IP68 black
ThreadPG
Fits to conduit sizeNW metric
Threadlength
External dimensions
Bestell-Nr.IP68schwarz
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge
Aussen-masse
• High-gradeformulatedpolyamide6,thread and integrated swivel adapter made from nickel-plated brass• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Suitableforoccasionalrotation• Roundguidancewithintheconnector• Easyintroductionofwiresandcables• Vibration-proofconnectiontoPMAFLEXconduits• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery:Fitting with oval clips (OVN2), conduit and thread seals (NVN3, SVN4 or OR)
• HochwertigformuliertesPolyamid6,Gewindeundintegrierter, drehbarer Adapter aus Messing vernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• GeeignetfürgelegentlicheDrehbewegungen• RundeFührunginnerhalbderVerschraubung• EinfachesEinziehenvonEinzeladernoderKabeln• VibrationssichereVerbindungzuPMA-Schutzrohren• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:ArmaturmitOval-Sperren(OVN2), Rohr-undGewindedichtung(NVN3,SVN4oderOR)
• High-gradeformulatedpolyamide6,thread and integrated swivel adapter made from nickel-plated brass• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Suitableforoccasionalrotation• Roundguidancewithintheconnector• Easyintroductionofwiresandcables• Vibration-proofconnectiontoPMAFLEXconduits• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery:Fitting with oval clips (OVN2), conduit and thread seals (NVN3, SVN4 or OR)
• HochwertigformuliertesPolyamid6,Gewindeundintegrierter, drehbarer Adapter aus Messing vernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• GeeignetfürgelegentlicheDrehbewegungen• RundeFührunginnerhalbderVerschraubung• EinfachesEinziehenvonEinzeladernoderKabeln• VibrationssichereVerbindungzuPMA-Schutzrohren• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:ArmaturmitOval-Sperren(OVN2), Rohr-undGewindedichtung(NVN3,SVN4oderOR)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
95For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Swivel Connectors / Drehbare Armaturen
MAVIK Positioning Elbow Adapter with various outlet angles, metric Positionierbarer Winkeladapter mit unterschiedlichen Abgangswinkeln, metrisch•Forhighloads•Wherecertaincableoutletanglesarerequired
•BeihohermechanischerBeanspruchung•WospezielleAbgangsrichtungenderKabelerforderlichsind
MAVIK-M20/01 M20x1.5 M20x1.5 10.0 35.0 52.0 MAVIK-M25/01 M25x1.5 M25x1.5 11.0 39.0 58.0 MAVIK-M32/01 M32x1.5 M32x1.5 13.0 46.0 61.0 MAVIK-M40/01 M40x1.5 M40x1.5 13.0 55.0 69.5 MAVIK-M50/01 M50x1.5 M50x1.5 14.0 65.0 83.0MAVIK-M63/01 M63x1.5 M63x1.5 14.0 80.0 92.0
Order No. Thread metricinside outside
Threadlength
Diameter Length 01 / 45°
Bestell-Nr. Gewinde,metrischinnen aussen
Gewinde-länge
Durchmesser Länge01 / 45°
• Adaptermadefromnickel-platedaluminium(othermaterialse.g.stainless steel or nickel-plated brass available on request), counter nut made from nickel-plated brass• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Thecounternutallowsaccuratepositioningoftheoutletdirectionin threaded holes• Availableoutletdirections: –45°(MAVIK-Mxx/01) –30° (MAVIK-Mxx/02) on request –15° (MAVIK-Mxx/03) on request• IP68static/IP67dynamic• Temperaturerange: –60 °C to +105 °C• Contentofdelivery:Elbow adapter with thread edge protection and O-Ring OR
• AdapterausAluminiumvernickelt(andereMaterialienwiez.B.Edelstahl oderMessingvernickeltaufAnfragemöglich),KontermutterausMessing vernickelt• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• DieKontermutterermöglichteineexakteEinstellungderAbgangsrichtung in einer bestehenden Gewindebohrung• ErhältlicheAbgangsrichtungen: –45°(MAVIK-Mxx/01) –30°(MAVIK-Mxx/02)aufAnfrage –15°(MAVIK-Mxx/03)aufAnfrage• IP68statisch/IP67dynamisch• Temperaturbereich:–60°Cbis+105°C• Lieferumfang:Winkeladapter mit Gewindekantenschutz und O-Ring OR
Dimensions / Dimensionen in mm
MAVI Special elbow adapter, metric with various outlet angles Spezial-Winkeladapter, metrisch mit unterschiedlichen Abgangswinkeln•Forhighloads•Wherecertaincableoutletanglesarerequired
•BeihohermechanischerBeanspruchung•WospezielleAbgangsrichtungenderKabelerforderlichsind
MAVI-M20/01 M20x1.5 M20x1.5 10.0 35.0 45.0 MAVI-M25/01 M25x1.5 M25x1.5 11.0 39.0 51.0 MAVI-M32/01 M32x1.5 M32x1.5 13.0 46.0 54.0 MAVI-M40/01 M40x1.5 M40x1.5 13.0 55.0 62.0 MAVI-M50/01 M50x1.5 M50x1.5 14.0 65.0 75.0MAVI-M63/01 M63x1.5 M63x1.5 14.0 80.0 84.0
Order No. Thread metricinside outside
Threadlength
Diameter Length 01 / 45°
Bestell-Nr. Gewinde,metrischinnen aussen
Gewinde-länge
Durchmesser Länge01 / 45°
• Nickel-platedaluminium(othermaterialse.g.stainless steel or nickel-plated brass available on request)• Veryhighimpactresistance• Highthreadandsystemconnectionstrength• Enablesdifferentmountingpositions: – with a lock nut behind a clearance hole – in threaded holes (lock nut on MAVI side for positioning) – with SCA spin-coupler• Availableoutletdirections: –45°(MAVI-Mxx/01) –30° (MAVI-Mxx/02) on request –15° (MAVI-Mxx/03) on request• IP68static/IP67dynamic• Temperaturerange: –60 °C to +105 °C• Contentofdelivery:Elbow adapter with thread edge protection, flatgasketforthreadsSVN4andO-RingOR
• Aluminiumvernickelt(andereMaterialienwiez.B.Edelstahl oderMessingvernickeltaufAnfragemöglich)• HervorragendeSchlagfestigkeit• HoheGewinde-undSystemverbindungsfestigkeit• ErmöglichtunterschiedlichePositionierungen: – mit Gegenmutter hinter dem Durchgangsloch –inGewindebohrungen(GegenmutteraufderMAVI-SeitezurPositionierung) –mitSCA-Positionsadapter• ErhältlicheAbgangsrichtungen: –45°(MAVI-Mxx/01) –30°(MAVI-Mxx/02)aufAnfrage –15°(MAVI-Mxx/03)aufAnfrage• IP68statisch/IP67dynamisch• Temperaturbereich:–60°Cbis+105°C• Lieferumfang:Winkeladapter mit Gewindekantenschutz, GewindeflachdichtungSVN4undO-RingOR
Dimensions / Dimensionen in mm
96 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Swivel Adapters / Drehadapter
SWA Swivel Adapters, metric / Drehadapter, metrisch
SWA Swivel Adapters, PG / Drehadapter, PG
•AllowPMAconnectorstoswivelfreelyinapplications where such movements is occasionally necessary
•ErmöglichteineDrehbewegungodergelegentliche AuslenkungvonPMA-VerschraubungenimBetrieb
•AllowPMAconnectorstoswivelfreelyinapplications where such movements is occasionally necessary
•ErmöglichteineDrehbewegungodergelegentliche AuslenkungvonPMA-VerschraubungenimBetrieb
SWA-M16-10 M16x1.5 23.0 37.5 SWA-M20-10 M20x1.5 27.0 38.5 SWA-M25-11 M25x1.5 32.0 41.0 SWA-M32-13 M32x1.5 45.0 46.5 SWA-M40-13 M40x1.5 55.0 47.5 SWA-M50-14 M50x1.5 59.0 49.5 SWA-M63-14 M63x1.5 75.0 52.0
SWA-P09 9 23.0 44.5 SWA-P11 11 27.0 45.5 SWA-P16 16 32.0 48.0 SWA-P21 21 40.0 51.0 SWA-P29 29 50.0 52.0 SWA-P36 36 59.0 55.0 SWA-P48 48 70.0 55.0
Order No. IP67
Threadmetric
OutsideDiameter
DimensionsLength
Bestell-Nr. IP67
Gewindemetrisch
Aussen-Durchmesser
DimensionenLänge
Order No. IP67
ThreadPG
OutsideDiameter
DimensionsLength
Bestell-Nr. IP67
GewindePG
Aussen-Durchmesser
DimensionenLänge
• Nickel-platedbrass• InconnectionwithPMAconnectorswithmetalthreads• Withthreadedgeprotection• WithcorrespondingsealsuptoIP67/IP68• Temperaturerange: –40 °C to +105 °C• Contentofdelivery:Adapter, thread seal (SVN4 or OR)
• Messinggalvanischvernickelt• InVerbindungmitPMA-VerschraubungenmitMetallgewinde• MitGewindekantenschutz• MitentsprechendemDichtungssatzbisIP67/IP68• Temperaturbereich: –40 °C bis +105 °C• Lieferumfang:Adapter,Gewindedichtung(SVN4oderOR)
• Nickel-platedbrass• InconnectionwithPMAconnectorswithmetalthreads• Withthreadedgeprotection• WithcorrespondingsealsuptoIP67/IP68• Temperaturerange: –40 °C to +105 °C• Contentofdelivery:Adapter, thread seal (SVN4 or OR)
• Messinggalvanischvernickelt• InVerbindungmitPMA-VerschraubungenmitMetallgewinde• MitGewindekantenschutz• MitentsprechendemDichtungssatzbisIP67/IP68• Temperaturbereich: –40 °C bis +105 °C• Lieferumfang:Adapter,Gewindedichtung(SVN4oderOR)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
97For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Spin Couplers / Positionsadapter
SCA Spin-Couplers, metric / Positionsadapter, metrisch
SCA Spin-Couplers, PG / Positionsadapter, PG
•Allowtheeasypositioningofelbowconnectors with metal thread
•ErmöglichtdieeinfachePositionierungvon Winkel-Verschraubungen mit Metallgewinde
•Allowtheeasypositioningofelbowconnectors with metal thread
•ErmöglichtdieeinfachePositionierungvon Winkel-Verschraubungen mit Metallgewinde
SCA-M16-10 M16x1.5 22.0 32.0 SCA-M20-10 M20x1.5 26.0 33.0 SCA-M25-11 M25x1.5 32.0 35.0 SCA-M32-13 M32x1.5 39.0 39.5 SCA-M40-13 M40x1.5 50.0 41.0 SCA-M50-14 M50x1.5 59.0 43.5 SCA-M63-14 M63x1.5 75.0 45.5
SCA-P09 9 22.0 35.0 SCA-P11 11 26.0 36.0 SCA-P16 16 29.0 38.0 SCA-P21 21 39.0 41.0 SCA-P29 29 44.0 42.5 SCA-P36 36 59.0 49.0 SCA-P48 48 69.0 50.5
Order No. IP68
Threadmetric
OutsideDiameter
DimensionsLength
Bestell-Nr. IP68
Gewindemetrisch
Aussen-Durchmesser
DimensionenLänge
Order No. IP68
ThreadPG
OutsideDiameter
DimensionsLength
Bestell-Nr. IP68
GewindePG
Aussen-Durchmesser
DimensionenLänge
• Nickel-platedbrass• InconnectionwithPMAconnectorswithmetalthreads• Highfasteningtorque• Withthreadedgeprotection• UptoIP68(IEC60529/EN60529)• Temperaturerange: –40 °C to +105 °C• Contentofdelivery:Adapter, thread seal (SVN4)
• Messinggalvanischvernickelt• InVerbindungmitPMA-VerschraubungenmitMetallgewinde• HohesFeststellmoment• MitGewindekantenschutz• BiszuIP68(IEC60529/EN60529)• Temperaturbereich: –40 °C bis +105 °C• Lieferumfang:Adapter,Gewindedichtung(SVN4)
• Nickel-platedbrass• InconnectionwithPMAconnectorswithmetalthreads• Highfasteningtorque• Withthreadedgeprotection• UptoIP68(IEC60529/EN60529)• Temperaturerange: –40 °C to +105 °C• Contentofdelivery:Adapter, thread seal (SVN4)
• Messinggalvanischvernickelt• InVerbindungmitPMA-VerschraubungenmitMetallgewinde• HohesFeststellmoment• MitGewindekantenschutz• BiszuIP68(IEC60529/EN60529)• Temperaturbereich: –40 °C bis +105 °C• Lieferumfang:Adapter,Gewindedichtung(SVN4)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
98 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Connections / Verbindungen
VN-REM Connection to solid tube metric Verbindung zu starrem metrischen Glattrohr
VN-RE Connection to solid tube PG Verbindung zu starrem PG-Glattrohr
•Inrailwayvehicleconstructionandotherapplicationswhere metricmetaltubesaretobeconnectedwiththeflexible PMAFLEX system
•ImSchienenfahrzeugbauundanderenAnwendungen,wo metrische,glatteMetallrohremitdemflexiblenPMAFLEX- Systemverbundenwerden
•Inrailwayvehicleconstructionandotherapplicationswhere metricmetaltubesaretobeconnectedwiththeflexible PMAFLEX system
•ImSchienenfahrzeugbauundanderenAnwendungen,wo metrische,glatteMetallrohremitdemflexiblenPMAFLEX- Systemverbundenwerden
*VNR-REM162 *VNR-REM162-24 12 16 M16 16.0 54.0 *VNR-REM187 *VNR-REM187-28 17 20 M16 18.5 65.0 *VNR-REM207 *VNR-REM207-28 17 20 M20 20.0 65.0 *VNR-REM253 *VNR-REM253-32 23 25 M25 26.0 71.0 *VNR-REM329 *VNR-REM329-44 29 32 M32 32.0 71.0 *VNR-REM406 *VNR-REM406-50 36 40 M40 40.0 90.0*VNR-REM508 *VNR-REM508-65 48 50 M50 50.0 90.0
*VNR-RE12 *VNR-RE12-24 12 16 PG11 18.5 56.0 *VNR-RE1317 *VNR-RE1317-28 17 20 PG13 20.4 65.0 *VNR-RE17 *VNR-RE17-28 17 20 PG16 22.5 65.0 *VNR-RE23 *VNR-RE23-32 23 25 PG21 28.5 71.0 *VNR-RE29 *VNR-RE29-44 29 32 PG29 37.0 71.0 *VNR-RE36 *VNR-RE36-50 36 40 PG36 47.0 84.0 *VNR-RE48 *VNR-RE48-65 48 50 PG48 59.3 90.0
Order No. IP68 without clamp
Order No. IP68 with clamp
Fits to conduit sizeNW metric
Steel tubemetric
InsideDiameter
OverallLength
Bestell-Nr.IP68ohne Schlauchbr.
Bestell-Nr.IP68mit Schlauchbr.
Passend zu RohrgrösseNW metrisch
Stahlrohr metrisch
Innen-Durchmesser
Gesamt-länge
Order No. IP68 without clamp
Order No. IP68 with clamp
Fits to conduit sizeNW metric
Steel tubePG
InsideDiameter
OverallLength
Bestell-Nr.IP68ohne Schlauchbr.
Bestell-Nr.IP68mit Schlauchbr.
Passend zu RohrgrösseNW metrisch
Stahlrohr PG
Innen-Durchmesser
Gesamt-länge
• High-grade,speciallyformulatedpolyamide6,jubileeclipmadeof galvanised bright steel• Veryhighimpactresistance• QuickconnectionofsolidmetaltubeswithflexiblePMAconduits• Availablewithorwithoutjubileeclip• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VNR:IP68 static / IP67 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68: Fittingwithovalclips(OVN2),conduitseal (NVN3), clamp according to order number IP68GT: Fittingwithpre-assembleduniveralsafetyclips(AFN2)and conduit seal (NVN3-GT); clamp according to order no.)
• Hochwertiges,speziellformuliertesPolyamid6,Schlauchbrideaus Stahlglanzverzinkt• HervorragendeSchlagfestigkeit• SchnelleVerbindungvonglattenMetallrohrenzuflexiblenPMA-Wellrohren• ErhältlichmitoderohneSchlauchbride• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)odergrob(G)• VNR: IP68statisch/IP67dynamisch,rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3), SchlauchbridegemässBestell-Nummer IP68GT: ArmaturmitvormontierterUniversal-Sicherheits-Sperre(AFN2) undRohrdichtung(NVN3-GT);Schlauchbridegem.Bestell-Nr.
• High-grade,speciallyformulatedpolyamide6,jubileeclipmadeof galvanised bright steel• Veryhighimpactresistance• QuickconnectionofsolidmetaltubeswithflexiblePMAconduits• Availablewithorwithoutjubileeclip• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• VNR:IP68 static / IP67 dynamic, conduit side• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP68: Fittingwithovalclips(OVN2),conduitseal (NVN3), clamp according to order number IP68GT: Fittingwithpre-assembleduniveralsafetyclips(AFN2)and conduit seal (NVN3-GT); clamp according to order no.)
• Hochwertiges,speziellformuliertesPolyamid6,Schlauchbrideaus Stahlglanzverzinkt• HervorragendeSchlagfestigkeit• SchnelleVerbindungvonglattenMetallrohrenzuflexiblenPMA-Wellrohren• ErhältlichmitoderohneSchlauchbride• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)odergrob(G)• VNR: IP68statisch/IP67dynamisch,rohrseitig• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP68: ArmaturmitOval-Sperren(OVN2),Rohrdichtung(NVN3), SchlauchbridegemässBestell-Nummer IP68GT: ArmaturmitvormontierterUniversal-Sicherheits-Sperre(AFN2) undRohrdichtung(NVN3-GT);Schlauchbridegem.Bestell-Nr.
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
IP68GT available. Please add “GT” to order no. or insert before clamp size (e.g. BVNR-REM162GT, BVNR-REM162GT24). (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”andieBestellnummeranfügenbzw.vorderBriden-Grösseeinfügen(z.B.BVNR-REM162GT,BVNR-REM162GT24).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
IP68GT available. Please add “GT” to order no. or insert before clamp size (e.g. BVNR-RE12GT, BVNR-RE12GT24). (Functional description PMAFIX IP68GT, page 50/53).IP68GTverfügbar.Bitte“GT”andieBestellnummeranfügenbzw.vorderBriden-Grösseeinfügen(z.B.BVNR-RE12GT,BVNR-RE12GT24).(FunktionsbeschreibungPMAFIXIP68GT,S.50/53).
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
99For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Connections and Conduit Adapters / Verbindungen und Rohradapter
VSG Connection splices for flexible conduits Verbindungsmuffe für Wellrohre
AV Conduit Adapters / Rohradapter
•Inrailwayvehicleconstructionandmachinetool •ImMaschinen-undBahnbau
•InconnectionwithPMAFIX/PMAFLEXsystem •InVerbindungmitPMAFIX-/PMAFLEX-System
*VSGD-1212GT *VSGR-1212 12 16 23.5 66.0 *VSGD-1717GT *VSGR-1717 17 20 29.5 87.0 *VSGD-2323GT *VSGR-2323 23 25 37.0 103.0 *VSGD-2929GT *VSGR-2929 29 32 44.0 100.0 *VSGD-3636GT *VSGR-3636 36 40 53.5 130.0 *VSGD-4848GT *VSGR-4848 48 50 66.0 133.0
BAVD-10/07GT BAVR-10/07 10 12 07 10 43.0BAVD-12/10GT BAVR-12/10 12 16 10 12 46.0 BAVD-17/10GT BAVR-17/10 17 20 10 12 53.0 BAVD-17/12GT BAVR-17/12 17 20 12 16 54.0 BAVD-23/10GT BAVR-23/10 23 25 10 12 54.0 BAVD-23/12GT BAVR-23/12 23 25 12 16 53.0 BAVD-23/17GT BAVR-23/17 23 25 17 20 62.0 BAVD-29/10GT BAVR-29/10 29 32 10 12 56.5 BAVD-29/12GT BAVR-29/12 29 32 12 16 55.0 BAVD-29/17GT BAVR-29/17 29 32 17 20 61.0 BAVD-29/23GT BAVR-29/23 29 32 23 25 64.0 BAVD-36/29GT BAVR-36/29 36 40 29 32 81.0 BAVD-48/36GT BAVR-48/36 48 50 36 40 88.5
Order No. IP66
Order No. IP68
Fits to conduit sizeNW metric
OutsideDiameter
Overalllength
Bestell-Nr. IP66
Bestell-Nr. IP68
Passend zu RohrgrösseNW metrisch
Aussen- Durchmesser
Gesamt-länge
Order No. IP66, black
Order No. IP68, black
Input fits to conduit sizeNW metric
Output fits to conduit sizeNW metric
Overalllength
Bestell-Nr. IP66,schwarz
Bestell-Nr. IP68,schwarz
Eingang passend zu Rohrgr.NW metrisch
Ausgang passend zu Rohrgr.NW metrisch
Gesamt-länge
• High-gradeformulatedpolyamide• One-piecePMAFIXconnection• Self-extinguishing• Freefromhalogensandcadmium• Highpull-outstrength• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66:Connectionsplicewithpre-installeduniversalsafetyclips(AFN2) IP68:Connectionsplicewithovalclips(OVN2),conduitseal(NVN3)
• HochwertigformuliertesPolyamid• EinteiligePMAFIX-Verbindung• Selbstverlöschend• Halogen-undcadmiumfrei• HoheAusreisskräfte• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66:VerbindungsmuffemitvormontiertenUniversal-Sicherheits- sperren(AFN2) IP68:VerbindungsmuffemitOval-Sperren(OVN2),Rohrdichtung(NVN3)
• High-grade,speciallyformulatedpolyamide6• Veryhighimpactresistance• AllowsvariableapplicationofthePMAFIXsystemparticularlyof PMA distribution pieces• Highconduitpull-outstrength• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: IP66:Adapterwithpre-assembleduniversalsafetyclips(AFN2) IP68:Adapterwithovalclips(OVN2),conduitseal(NVN3)
• Hochwertiges,speziellformuliertesPolyamid• HervorragendeSchlagfestigkeit• ErmöglichtvariableAnwendungenvonPMAFIX-Systeminsbesondere vonPMA-Verteilern• HoheWellrohr-Ausreisskräfte• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang: IP66:AdaptermitvormontiertenUniversal-Sicherheitssperren(AFN2) IP68:AdaptermitOval-Sperren(OVN2),Rohdichtung(NVN3)
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
* = Replace with “B” to order black or “S” to order grey / *=ErsetzenSie“B”fürschwarzoder“S”fürgrau
100 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Special Products / Spezialprodukte
Terminal and Protection Sleeves / Endtüllen und Schutzmuffen
CT Conduit Termination / Wellrohr-Endabschlusshülse
RKS Conduit Terminal Sleeves / Wellrohr-Endtüllen
SS/SV Abrasion Protection Sleeves / Scheuerschutz-Muffen
•ForsealingofcablesandwiresattheexitfromPMA corrugated conduits•Avoidsingressionofdirtandliquids
•ZurAbdichtungvonKabelnundLeitungenbeimAustrittaus PMA-Wellrohren•VerhindertdasEindringenvonSchmutzundFlüssigkeiten
•Usedattheendofconduitswherenoconnectorswith threads are necessary
•EingesetztalsWellrohrabschlusswokeineGewinde- Verschraubungen benötigt werden
•Abrasionprotectionforcorrugatedconduitsinposition exposedtochafing
•AlsScheuerschutzfürWellrohreanbesonders abriebgefährdetenStellen
BCT-10 10 12 4 – 8 28.0 13.0 BCT-12 12 16 5 – 9 35.0 16.0 BCT-17 17 20 7 – 14 42.0 21.0 BCT-23 23 25 14 – 22 51.0 28.0 BCT-29 29 32 16 – 30 53.0 34.0 BCT-36 36 40 16 – 34 55.0 42.0
RKS-07 7 10 4.5 12.5 16.0 RKS-10 10 12 8.0 15.5 16.0 RKS-12 12 16 10.0 19.0 20.0 RKS-17 17 20 13.0 24.0 21.0 RKS-23 23 25 20.0 32.0 22.0 RKS-29 29 32 25.0 38.0 22.0 RKS-36 36 40 33.5 46.0 25.0 RKS-48 48 50 45.0 58.0 25.0 RKS-56 56 63 54.0 71.0 28.0
BSS-17 17 20 42.0 22.0 BSS-23 23 25 49.0 26.0 BSS-29 29 32 55.0 26.0 BSS-36 36 40 63.0 30.0 BSS-48 48 50 75.0 30.0
BSS-56G 56 – 90.0 33.0 BSV-70G 70 – 108.0 60.0
Order No. black
Fits to conduit sizeNW metric
Clampingrange
Length Height
Bestell-Nr. schwarz
Passend zu RohrgrösseNW metrisch
Klemm-bereich
Länge Höhe
Order No. black
Fits to conduit sizeNW metric
InsideDiameter
OutsideDiameter
DimensionsLength
Bestell-Nr. schwarz
Passend zu RohrgrösseNW metrisch
Innen- Durchmesser
Aussen- Durchmesser
DimensionenLänge
Order No. black
Fits to conduit sizeNW metric
OutsideDiameter
DimensionsLength
Bestell-Nr. schwarz
Passend zu RohrgrösseNW metrisch
Aussen- Durchmesser
DimensionenLänge
• Neoprenerubber• Temperaturerange: –30 °C to +120 °C
• Neoprenkautschuk• Temperaturbereich:–30°Cbis+120°C
• Speciallymodifiedpolyamide• Self-extinguishing• Freefromhalogensandcadmium• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C
• SpeziellmodifiziertesPolyamid• Selbstverlöschend•Halogen-undcadmiumfrei• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C
• High-grade,speciallymodifiedpolyamide6• Increasedthelifetimeofmovingconduits• Excellentchafingcharacteristics• Verygoodchemicalproperties• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C• Contentofdelivery: Abrasion protection sleeves with assembling screws
• Hochwertiges,speziellmodifiziertesPolyamid6• ErhöhtdieLebensdauerstarkbewegterWellrohre• HervorragendeAbriebeigenschaften• SehrgutechemischeEigenschaften•Halogen-undcadmiumfrei• PassendzuRohrprofilfein(T)odergrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C• Lieferumfang:ScheuerschutzmuffenmitVerbindungsschrauben
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
NEW /
NEU
101For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Clips / Sperren
AFN2 Universal Safety Clips / Universal-Sicherheitssperren
OVN2 Oval Clips / Oval-Sperren
WPS Water Impact Protections / Wasserprallschutz
•Pre-installedintheIP66andIP68GTrangeofconnectors•AllowforaquickandeasyconnectiontoPMAFLEXconduits byjustpushingtheconduitintotheconnector
•IndenPMA-VerschraubungenfürIP66-undIP68GT- Verbindungen vormontiert•GestatteneineschnelleundsichereMontagevonPMAFLEX Wellrohren durch einfaches Einstossen in die Verschraubung
•UsedtosecuretheconduitwithinthePMAFIXconnectors and distributors by easy installation by hand•Thusconnectionswithahighdegreeofsafetyarepossible
•EingesetztdurcheinfacheHandmontagezurFixierungder PMA-WellrohreinPMAFIX-VerschraubungenundVerteilern•DadurchentstehenVerbindungenmithöchstmöglicher Sicherheit
•IncreasedprotectionofPMAFIXfittingsagainstwaterjet impact•Forincreasedingressprotectionrequirementsregarding highpressure/steamjetcleaning
•ZusätzlicherDichtheitsschutzvonVerschraubungenvor starkemStrahlwasser•BeierhöhtenDichtheitsanforderungengegenüberHochdruck/ Dampfstrahlreinigung
AFN2-07GT 7 G + T 14.0 14.0 7.0 AFN2-10GT 10 G + T 17.5 17.0 8.0 AFN2-12GT 12 G + T 20.5 20.0 7.3 AFN2-17GT 17 G + T 26.5 22.0 8.0 AFN2-23GT 23 G + T 34.0 27.5 11.8 AFN2-29GT 29 G + T 40.5 32.0 11.8 AFN2-36GT 36 G + T 49.5 38.8 9.5 AFN2-48GT 48 G + T 62.0 47.0 9.5
OVN2-07 7 G + T 14.0 14.0 6.0 OVN2-10 10 G + T 17.5 17.0 7.0 OVN2-12 12 G + T 21.0 19.0 6.0 OVN2-17 17 G + T 26.5 22.5 7.0 OVN2-23 23 G + T 34.0 27.5 10.5 OVN2-29 29 G + T 40.5 32.0 10.5 OVN2-36 36 G + T 49.5 39.0 8.5 OVN2-48 48 G + T 62.0 47.0 8.5
WPS-NW10 10 G + T 22.0 8.0 WPS-NW12 12 G + T 26.0 8.0 WPS-NW17 17 G + T 33.0 8.0 WPS-NW23 23 G + T 40.0 9.0 WPS-NW29 29 G + T 47.0 9.5 WPS-NW36 36 G + T 59.0 10.0 WPS-NW48 48 G + T 71.0 10.0
Order No. IP66, dark grey
Fits to conduit sizeNW profile
DimensionsWidth
DimensionsLength
DimensionsThickness
Bestell-Nr. IP66,dunkelgrau
Passend zu RohrgrösseNW Profil
Dimensionen Breite
Dimensionen Länge
Dimensionen Dicke
Order No. IP68, dark grey
Fits to conduit sizeNW profile
DimensionsWidth
DimensionsLength
DimensionsThickness
Bestell-Nr. IP68,dunkelgrau
Passend zu RohrgrösseNW Profil
Dimensionen Breite
Dimensionen Länge
Dimensionen Dicke
Order No. IP69, black
Fits to conduit sizeNW profile
Outside Diameter
DimensionsThickness
Bestell-Nr. IP69,schwarz
Passend zu RohrgrösseNW Profil
Aussen-Durchmesser
Dimensionen Dicke
• High-gradeformulatedpolyamide• Self-extinguishing• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C
• HochwertigformuliertesPolyamid• Selbstverlöschend• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C
• High-gradeformulatedpolyamide• Self-extinguishing• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C; Short-term to +160 °C
• HochwertigformuliertesPolyamid• Selbstverlöschend• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich:–40°Cbis+105°C;Kurzzeitigbis+160°C
• High-grade,speciallyformulatedpolyamide6,extremelyshockresistant• Self-extinguishing• Freefromhalogensandcadmium• BasedonPMAFIX/PMAFLEXsystemwithingressprotectionofIP68• Add.protectionagainstwaterjetimpact-increasedprot.uptoIP69K• Two-piecewaterimpactprotectionwithclickcap• Possibleforsubsequentinstallation,highretentionforces• FitstoallPMAFLEXconduitprofiles• Temperaturerange: –45 °C to +105 °C; Short-term to +160 °C
• Hochwertiges,speziellformuliertesPolyamid,hervorragendeSchlagfest.• Selbstverlöschend• Halogen-undcadmiumfrei• AlsBasisdientdasPMAFIX/PMAFLEX-System• ZusätzlicherstarkerStrahlwasserschutz-erhöhteDichtheitbisIP69K• ZweiteiligerWasserprallschutzmitSchnappverschluss• NachträglicheInstallationmöglich,hoheHaltekräfte• PassendzuallenPMAFLEX-Rohrprofilen• Temperaturbereich:–45°Cbis+105°C;Kurzzeitigbis+160°C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
102 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Lock Nuts, Polyamide / Gegenmuttern, Polyamid
MN Hexagonal Lock Nuts, metric / 6-kant Gegenmuttern, metrisch
MN Hexagonal Lock Nuts, PG / 6-kant Gegenmuttern, PG
BMN-M12 GMN-M12 M12x1.5 17 5.0 BMN-M16 GMN-M16 M16x1.5 22 5.0 BMN-M20 GMN-M20 M20x1.5 26 5.6 BMN-M25 GMN-M25 M25x1.5 32 6.0 BMN-M32 GMN-M32 M32x1.5 41 7.0 BMN-M40 GMN-M40 M40x1.5 50 7.0 BMN-M50 GMN-M50 M50x1.5 60 8.0 BMN-M63 GMN-M63 M63x1.5 75 8.0
BMN-07 GMN-07 7 19 5.0 BMN-09 GMN-09 9 22 5.0 BMN-11 GMN-11 11 24 5.0 BMN-13 GMN-13 13.5 27 6.0 BMN-16 GMN-16 16 30 6.0 BMN-21 GMN-21 21 36 7.0 BMN-29 GMN-29 29 46 7.0 BMN-36 GMN-36 36 60 8.0 BMN-48 GMN-48 48 70 8.0
Order No. black
Order No. grey
Fits to threadmetric
WrenchSize
DimensionsHeight
Bestell-Nr. schwarz
Bestell-Nr. grau
Passend zu Gewindemetrisch
Schlüssel- weite
DimensionenHöhe
Order No. black
Order No. grey
Fits to threadPG
WrenchSize
DimensionsHeight
Bestell-Nr. schwarz
Bestell-Nr. grau
Passend zu GewindePG
Schlüssel- weite
DimensionenHöhe
• High-grade,speciallyformulatedpolyamide6,30%glassfibrereinforced• Hightighteningtorques• Safesystemconnection• Verygoodchemicalproperties• Freefromhalogensandcadmium• Temperaturerange: –40 °C to +105 °C; Short-term to +150 °C
• Hochwertiges,speziellmodifiziertesPolyamid6,30%glasfaserverstärkt• HoheAnzugsdrehmomente• SichereSystemverbindung• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +150 °C
• High-grade,speciallyformulatedpolyamide6,30%glassfibrereinforced• Hightighteningtorques• Safesystemconnection• Verygoodchemicalproperties• Freefromhalogensandcadmium• Temperaturerange: –40 °C to +105 °C; Short-term to +150 °C
• Hochwertiges,speziellmodifiziertesPolyamid6,30%glasfaserverstärkt• HoheAnzugsdrehmomente• SichereSystemverbindung• SehrgutechemischeEigenschaften• Halogen-undcadmiumfrei• Temperaturbereich: –40 °C bis +105 °C; Kurzzeitig bis +150 °C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
103For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Lock Nuts, Metal / Gegenmuttern, Metall
MM Hexagonal Lock Nuts, metric, metal / 6-kant Gegenmuttern, metrisch, Metall
MM Hexagonal Lock Nuts, PG, metal / 6-kant Gegenmuttern, PG, Metall
GMM-M12 M12x1.5 15 2.8 GMM-M16 M16x1.5 19 2.8 GMM-M20 M20x1.5 24 3.0 GMM-M25 M25x1.5 30 3.5 GMM-M32 M32x1.5 36 4.0 GMM-M40 M40x1.5 46 4.5 GMM-M50 M50x1.5 60 5.0 GMM-M63 M63x1.5 70 5.5
GMM-07 7 15 2.8 GMM-09 9 18 2.8 GMM-11 11 21 3.0 GMM-13 13.5 23 3.0 GMM-16 16 26 3.0 GMM-21 21 32 3.5 GMM-29 29 41 4.0 GMM-36 36 51 5.0 GMM-42 42 60 5.0 GMM-48 48 64 5.5
Order No. metal
Fits to threadmetric
WrenchSize
DimensionsHeight (min.)
Bestell-Nr. Metall
Passend zu Gewindemetrisch
Schlüssel- weite
DimensionenHöhe (min.)
Order No. metal
Fits to threadPG
WrenchSize
DimensionsHeight (min.)
Bestell-Nr. Metall
Passend zu GewindePG
Schlüssel- weite
DimensionenHöhe (min.)
• Nickel-platedbrass• maximumpossibletorque• Safesystemconnection
• Messinggalvanischvernickelt• HöchstmöglicheAnzugsdrehmomente• SichereSystemverbindung
• Nickel-platedbrass• maximumpossibletorque• Safesystemconnection
• Messinggalvanischvernickelt• HöchstmöglicheAnzugsdrehmomente• SichereSystemverbindung
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
104 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Enlargers and Reducers, Metric / Erweiterungen und Reduktionen, Metrisch
ME Enlargers, metric, brass / Erweiterungen, metrisch, Messing
MR Reducers, metric, brass / Reduktionen, metrisch, Messing
M12M16M M12x1.5 5 M16x1.5 7.0 8.0 16.0 18M16M20M M16x1.5 5 M20x1.5 7.5 12.0 16.5 22M20M25M M20x1.5 6 M25x1.5 8.0 15.0 18.5 27M25M32M M25x1.5 7 M32x1.5 9.0 21.0 20.5 34M32M40M M32x1.5 8 M40x1.5 10.0 26.0 23.5 42M40M50M M40x1.5 8 M50x1.5 13.0 34.0 30.0 52M50M63M M50x1.5 9 M63x1.5 16.0 44.0 32.5 65
M16M12M M16M12M/6 M16x1.5 M12x1.5M20M12M M20M12M/6 M20x1.5 M12x1.5M20M16M M20M16M/6 M20x1.5 M16x1.5M25M16M M25M16M/6 M25x1.5 M16x1.5M25M20M M25M20M/6 M25x1.5 M20x1.5M32M20M M32M20M/6 M32x1.5 M20x1.5M32M25M M32M25M/6 M32x1.5 M25x1.5M40M25M M40M25M/6 M40x1.5 M25x1.5M40M32M M40M32M/6 M40x1.5 M32x1.5M50M32M M50M32M/6 M50x1.5 M32x1.5M50M40M M50M40M/6 M50x1.5 M40x1.5M63M40M M63M40M/6 M63x1.5 M40x1.5M63M50M M63M50M/6 M63x1.5 M50x1.5
Order No. metal, standard
Thread outside metric length
Thread inside metric length
InsideDiameter
DimensionsHeight
Wrenchsize
Bestell-Nr. Metall,Standard
Gewinde aussen metrisch Länge
Gewinde innen metrisch Länge
Innen-Durchmesser
DimensionenHöhe
Schlüssel-weite
Order No. metal, standard
Order No. metal, hexagonal
Thread outsidemetric
Thread insidemetric
Bestell-Nr. Metall,Standard
Bestell-Nr. Metall,6kant
Gewinde aussenmetric
Gewinde innenmetric
• Nickel-platedbrass• Forenlargementofanexistingthread
• Messinggalvanischvernickelt• ZurErweiterungeinesbestehendenGewindes
• Nickel-platedbrass
• Messinggalvanischvernickelt
Dimensions / Dimensionen in mm
•Usedtoenlargemetricthreads•Easymounting,equippedwithhexagonalring
•ZurErweiterungvonmetrischenAnschlussgewinden•LeichteMontierbarkeitdankSechskant
•Usedtoreducemetricthreads•Availableinroundandhexagonalform
•ZurReduktionvonmetrischenAnschlussgewinden•ErhältlichinrunderundinSechskant-Ausführung
105For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
EnlargersandReducers,PG/Erweiterungen und Reduktionen, PG
ME Enlargers, PG, brass / Erweiterungen, PG, Messing
MR Reducers, PG, brass / Reduktionen, PG, Messing
0709M 7.0 5.0 9.0 7.0 17.0 15.0 0911M 9.0 6.0 11.0 7.0 20.0 16.5 0913M 9.0 6.0 13.5 7.5 22.0 17.5 1113M 11.0 6.0 13.5 8.0 22.0 17.5 1116M 11.0 6.5 16.0 8.5 24.0 19.0 1121M 11.0 6.5 21.0 10.0 30.0 21.0 1316M 13.5 6.5 16.0 7.5 24.0 19.0 1321M 13.5 6.5 21.0 8.5 30.0 21.0 1621M 16.0 6.5 21.0 8.5 30.0 21.0 1629M 16.0 6.5 29.0 11.0 39.0 22.5 2129M 21.0 7.0 29.0 11.5 39.0 23.0 2936M 29.0 8.0 29.0 12.0 50.0 27.5 4248M 42.0 10.0 42.0 17.0 64.0 33.0
0907M 9.0 6.0 7 17.0 8.5 1107M 11.0 6.0 7 20.0 8.5 1109M 11.0 6.0 9 20.0 8.5 1307M 13.5 6.5 7 22.0 9.0 1309M 13.5 6.5 9 22.0 9.0 1311M 13.5 6.5 11 22.0 9.0 1607M 16.0 6.5 7 24.0 9.5 1609M 16.0 6.5 9 24.0 9.5 1611M 16.0 6.5 11 24.0 9.5 1613M 16.0 6.5 13.5 24.0 9.5 2111M 21.0 7.0 11 30.0 10.0 2113M 21.0 7.0 13.5 30.0 10.0 2116M 21.0 7.0 16 30.0 10.0 2916M 29.0 8.0 16 39.0 11.5 2921M 29.0 8.0 21 39.0 11.5 3621M 36.0 9.0 21 50.0 12.5 3629M 36.0 9.0 29 50.0 12.5 4229M 42.0 10.0 29 57.0 14.0 4236M 42.0 10.0 36 57.0 14.0 4836M 48.0 10.0 36 64.0 14.0 4842M 48.0 10.0 42 64.0 14.0
Order No. metal, standard
Thread outside PG length
Thread inside PG length
OutsideDiameter
DimensionsTotal Length
Bestell-Nr. Metall,Standard
Gewinde aussen PG Länge
Gewinde innen PG Länge
Aussen-Durchmesser
Gesamt-länge
Order No. metal, standard
Thread outside PG length
Thread inside PG
OutsideDiameter
DimensionsTotal Length
Bestell-Nr. Metall,Standard
Gewinde aussen PG Länge
Gewinde innen PG
Aussen-Durchmesser
Gesamt-länge
• Nickel-platedbrass
• Messinggalvanischvernickelt
• Nickel-platedbrass
• Messinggalvanischvernickelt
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
•UsedtoenlargePGthreads •ZurErweiterungvonPG-Anschlussgewinden
•UsedtoreducePGthreads •ZurReduktionvonPG-Anschlussgewinden
106 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Reducers,PG/Reduktionen, PG
NR Reducers, PG, Polyamide / Reduktionen, PG, Polyamid
1109N 11 9 22.5 24.5 1309N 13.5 9 15.0 26.0 1311N 13.5 11 24.0 26.0 1609N 16 9 16.0 29.0 1611N 16 11 16.0 29.0 1613N 16 13.5 27.0 29.0 2113N 21 13.5 16.0 35.5 2116N 21 16 16.0 35.5 2921N 29 21 17.0 43.0 3629N 36 29 24.0 54.0
Order No. Thread outside PG
Thread inside PG
DimensionsLength
OutsideDiameter
Bestell-Nr. Gewinde aussen PG
Gewinde innen PG
DimensionenGesamtlänge
Aussen-Durchmesser
• Polyamideglassfibrereinforced• Temperaturerange: –30 °C to +100 °C
• Polyamidglasfaserverstärkt• Temperaturbereich: –30 °C bis +100 °C
Dimensions / Dimensionen in mm
•Usedtoreduceconnectingthreads •ZurReduktionvonAnschlussgewinden
107For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Sealing Caps / Rohrdichtungen
NVN3 Sealing Caps, reinforced, IP68 / Rohrdichtungen, verstärkt, IP68
NFN3 Sealing Caps, IP67 / Rohrdichtungen, IP67
NVN3-07 7 10 9.0 NVN3-09 10 12 9.0 NVN3-11 12 16 12.0 NVN3-16 17 23 16.5 NVN3-21 23 25 13.0 NVN3-29 29 32 14.0 NVN3-36 36 40 17.5 NVN3-48 48 50 17.5
NFN3-07 7 10 9.0 NFN3-09 10 12 9.0 NFN3-11 12 16 9.0 NFN3-16 17 23 9.0 NFN3-21 23 25 9.0 NFN3-29 29 32 9.0 NFN3-36 36 40 11.0 NFN3-48 48 50 11.0
Order No. black
Fits to conduit size NW
Fits to conduit size metric
DimensionsLength
Bestell-Nr. schwarz
passend zu Rohrgrösse NW
passend zu Rohrgrösse metrisch
DimensionenLänge
Order No. white
Fits to conduit size NW
Fits to conduit size metric
DimensionsLength
Bestell-Nr. weiss
passend zu Rohrgrösse NW
passend zu Rohrgrösse metrisch
DimensionenLänge
• Speciallymodifiedpolyesterelastomer• Suitableforsealing• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C
• SpeziellmodifiziertesPolyesterelastomer• GeeignetzurAbdichtung• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich: –40 °C bis +105 °C
• Speciallymodifiedpolyesterelastomer• Suitableforsealing• Freefromhalogensandcadmium• Fitsbothconduitprofiles–fine(T)andcoarse(G)• Temperaturerange: –40 °C to +105 °C
• SpeziellmodifiziertesPolyesterelastomer• GeeignetzurAbdichtung• Halogen-undcadmiumfrei• PassendzuRohrprofilenfein(T)undgrob(G)• Temperaturbereich: –40 °C bis +105 °C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
•InconnectionwithPMAFIXconnectors(„V“series)and PMAFLEX corrugated conduits
•InVerbindungmitdenPMAFIX-Verschraubungen („V“-Modelle)undPMAFLEX-Wellrohren
•InconnectionwithPMAFIXconnectors(„F“series)and PMAFLEX corrugated conduits
•InVerbindungmitdenPMAFIX-Verschraubungen („F“-Modelle)undPMAFLEX-Wellrohren
108 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
FlatGaskets/Gewindeflachdichtungen
SVN4 Flat Gaskets, metric / Gewindeflachdichtungen, metrisch
SVN4 Flat Gaskets, PG / Gewindeflachdichtungen, PG
SVN4-M12 M12x1.5 12.0 20.0 1.5 SVN4-M12/02 M12x1.5 12.0 23.0 1.5 SVN4-M16 M16x1.5 16.0 22.0 1.5 SVN4-M16/02 M16x1.5 16.0 25.0 1.5 SVN4-M20 M20x1.5 20.0 27.0 1.5 SVN4-M20/02 M20x1.5 20.0 33.0 1.5 SVN4-M25 M25x1.5 25.0 35.0 1.5 SVN4-M25/02 M25x1.5 25.0 39.0 1.5 SVN4-M32 M32x1.5 32.0 43.0 1.5 SVN4-M32/02 M32x1.5 32.0 49.0 1.5 SVN4-M40 M40x1.5 40.0 55.0 1.5 SVN4-M40/02 M40x1.5 40.0 64.0 1.5 SVN4-M50 M50x1.5 50.0 69.0 1.5 SVN4-M50/02 M50x1.5 50.0 74.0 1.5 SVN4-M63 M63x1.5 63.0 75.0 1.5
SVN4-07 7 12.5 16.5 1.5 SVN4-09 9 15.2 20.0 1.5 SVN4-11 11 18.6 24.0 1.5 SVN4-13 13.5 20.4 31.0 1.5 SVN4-16 16 22.5 31.0 1.5 SVN4-21 21 28.3 37.0 1.5 SVN4-29 29 37.0 48.0 1.5 SVN4-36 36 47.0 57.0 1.5 SVN4-42 42 54.0 60.0 1.5 SVN4-48 48 59.3 69.0 1.5
Order No. IP68
Fits to threadmetric
InsideDiameter
OutsideDiameter
DimensionsWidth
Bestell-Nr. IP68
passend zu Gewinde metrisch
Innen-Durchmesser
Aussen-Durchmesser
DimensionenBreite
Order No. IP68
Fits to threadPG
InsideDiameter
OutsideDiameter
DimensionsWidth
Bestell-Nr. IP68
passend zu Gewinde PG
Innen-Durchmesser
Aussen-Durchmesser
DimensionenBreite
• NBRreinforcedwitharamidefibres(asbestos-free)• UptoIP68• Temperaturerange:–50 °C to +200 °C; Short-term +350 °C
• NBRmitAramidfaserverstärkt (asbestfrei)• BiszuIP68• Temperaturbereich:–50°Cbis+200°C;Kurzzeitig+350°C
• NBRreinforcedwitharamidefibres(asbestos-free)• UptoIP68• Temperaturerange:–50 °C to +200 °C; Short-term +350 °C
• NBRmitAramidfaserverstärkt (asbestfrei)• BiszuIP68• Temperaturbereich:–50°Cbis+200°C;Kurzzeitig+350°C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
•SuitableforthereinforcedPMAFIXconnectorswith polyamide or metal threads •GuaranteeingressprotectionofuptoIP68
•FürdieverstärktenPMAFIX-ArmaturenmitPolyamid- oder Metallgewinden geeignet •GarantiereneineSchutzartvonbiszuIP68
•SuitableforthereinforcedPMAFIXconnectors with polyamide or metal threads •GuaranteeingressprotectionofuptoIP68
•FürdieverstärktenPMAFIX-ArmaturenmitPolyamid- oder Metallgewinden geeignet •GarantiereneineSchutzartvonbiszuIP68
109For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
FlatGaskets/Gewindeflachdichtungen
SVN4 Flat Gaskets, Gas / Gewindeflachdichtungen, Gas
SVN4-G00 ¼" 13.2 20.0 1.5 SVN4-G01 3⁄8" 16.7 22.0 1.5 SVN4-G02 ½" 21.0 28.0 1.5 SVN4-G04 ¾" 26.5 34.0 1.5 SVN4-G06 1" 33.3 42.0 1.5 SVN4-G07 1 ¼" 41.9 53.0 1.5 SVN4-G08 1 ½" 47.8 62.0 1.5 SVN4-G09 2" 59.6 69.0 1.5
Order No. IP68
Fits to threadGas
InsideDiameter
OutsideDiameter
DimensionsWidth
Bestell-Nr. IP68
passend zu Gewinde Gas
Innen-Durchmesser
Aussen-Durchmesser
DimensionenBreite
• NBRreinforcedwitharamidefibres(asbestos-free)• UptoIP68• Temperaturerange:–50 °C to +200 °C; Short-term +350 °C
• NBRmitAramidfaserverstärkt (asbestfrei)• BiszuIP68• Temperaturbereich:–50°Cbis+200°C;Kurzzeitig+350°C
Dimensions / Dimensionen in mm
•SuitableforthereinforcedPMAFIXconnectors with polyamide or metal threads •GuaranteeingressprotectionofuptoIP68
•FürdieverstärktenPMAFIX-ArmaturenmitPolyamid- oder Metallgewinden geeignet •GarantiereneineSchutzartvonbiszuIP68
110 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Plug Screws / Verschluss-Schrauben
514 Plug Screws, metric / Verschluss-Schrauben, metrisch
514 Plug Screws, PG / Verschluss-Schrauben, PG
514-M12 M12x1.5 15.0 10.0 6.0 514-M16 M16x1.5 20.0 10.5 6.0 514-M20 M20x1.5 24.0 10.5 6.0 514-M25 M25x1.5 30.0 13.0 8.0 514-M32 M32x1.5 37.0 13.0 8.0 514-M40 M40x1.5 46.0 14.0 8.0 514-M50 M50x1.5 56.0 16.5 10.0 514-M63 M63x1.5 70.0 17.0 12.0
514-07 7 15.0 8.0 6.0 514-09 9 19.0 9.5 6.5 514-11 11 22.0 10.0 6.5 514-13 13.5 25.0 10.0 6.5 514-16 16 27.0 10.0 6.5 514-21 21 33.0 12.0 8.0 514-29 29 44.0 11.5 8.0 514-36 36 55.0 14.0 10.0 514-48 48 68.0 16.0 12.0
Order No. grey
Fits to threadmetric
OutsideDiameter
DimensionsHeight
ThreadLength
Bestell-Nr. grau
passend zu Gewinde metrisch
Aussen-Durchmesser
DimensionenHöhe
Gewinde-länge
Order No. grey
Fits to threadPG
OutsideDiameter
DimensionsHeight
ThreadLength
Bestell-Nr. grau
passend zu Gewinde PG
Aussen-Durchmesser
DimensionenHöhe
Gewinde-länge
• Polyamide6V-2,gasketringmadefromchloroprenerubberCR• Freefromhalogensandcadmium• IP65withincludedgasketring• Temperaturerange:–30 °C to +100 °C
• Polyamid6V-2,DichtringausChloroprenkautschukCR• Halogen-undcadmiumfrei• IP65mitmitgeliefertemDichtring• Temperaturbereich:–30 °C bis +100 °C
• Polyamide6glassfibrereinforced• Freefromhalogensandcadmium• IP54• Temperaturerange: –30 °C to +100 °C
• Polyamid6glasfaserverstärkt• Halogen-undcadmiumfrei• IP54• Temperaturbereich: –30 °C bis +100 °C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
•Suitableforanaccurateterminationwherenothread holes in casing and distribution boxes are needed
•GeeignetzumsauberenVerschliessenvonnichtbenötigten Gewindebohrungen in Gehäusen oder Verteilerdosen
•Suitableforanaccurateterminationwherenothread holes in casing and distribution boxes are needed
•GeeignetzumsauberenVerschliessenvonnichtbenötigten Gewindebohrungen in Gehäusen oder Verteilerdosen
111For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Accessories / Zubehör
Tools / Werkzeuge
PMACUT Cutting Tools / Schneidewerkzeuge
EWZ Draw-In Tools / Einzugswerkzeuge
PMACUT-38 FP-38 0 – 38 mm 7 – 29PMACUT-52 FP-52 0 – 52 mm 23 – 48
EWZ-02 EWZ-03 7.5 – 34 117.7 x 45.2 x 71.9
Order No.Cutting Tool
Order No.Spare blade
Cuttingrange
For PMAFLEXNW
Bestell-Nr.Schneidewerkzeug
Bestell-Nr.Ersatzklinge
Schneide-bereich
FürPMAFLEXNW
Order No.black with hole
Order No.black with handle
Fits toconduit size NW
DimensionsWidth x Length x Depth
Bestell-Nr.schwarzmitLoch
Bestell-Nr.schwarz mit Griff
passend zuRohrgrösse NW
DimensionenBreitexLängexTiefe
• Material:Metal• Colour:red
• Material:Metall• Farbe:rot
• Material:Polyamide6.6• Colour:black
• Material:Polyamid6.6• Farbe:schwarz
Dimensions / Dimensionen in mm
•ExcellenttoolforcuttingallPMAconduits•Guaranteespreciseandsafe90°anglecut
•GeeignetzumSchneidenvonPMA-Wellrohren•Ermöglichteinenexakten,geradenundsicherenSchnittim rechten Winkel
•Suitablefordrawingincablesorwiresinto PMADivisibleSystemConduitsorotherslitconduits•Designedinahandyshapeandareequippedwith a practical hand grip for wedging or with hole for direct holding of the wires•Canbeusedwheneveradrawing-in assistance for slit conduits is helpful
•GeeignetfürdasEinziehenvoneinzelnenodermehreren Kabeln/Litzeningeschlitzte(Wellrohre)oderPMADivisible SystemWellrohre•LiegengutinderHandundsindmiteinempraktischen HaltegriffzumKlemmenodermitLochzumdirektenHalten der Leitungen ausgerüstet•FindenüberalldortAnwendung,wobeigeschlitzten Wellrohren eine Kabel-Einzugshilfe von Nutzen ist
112
Connectors: Part Number Code / Anschlüsse: Nummernschlüssel
Connector SeriesAnschlussarmatur-Baureihen
PMA Smart Line Part Number Code / Nummernschlüssel
straight (N)gerade (N)
45° elbow (A)45° Winkel (A)
90° curved elbow (W)90° Bogenwinkel (W)
Modes of Ingress Protection / Schutzart: IP66 static / IP54 dynamicIP66statisch/IP54dynamisch
Thread size (Table 2)Gewindegrösse (Tabelle 2)
Type/Typ: PMA Smart Line
Nominal width conduit (Table 1)Nennweite Wellrohr (Tabelle 1)
Series / Bauformen: N = straight / gerade A = 45° elbow / 45° Winkel W = 90° curved elbow / 90° Bogenwinkel
Colours / Farben: A = black / schwarz S = grey / grau
A L N D – M 20 7
Thread type / Gewindeart: P = PG Thread/PGGewindeM = Metric Thread / Metrisches Gewinde
113
Connectors / Anschlüsse
Overview and Size Codes / Übersicht und Grössen-Codierung PMA Smart Line
Connectors: Part Number Code / Anschlüsse: Nummernschlüssel
Fittings:•One-piece–readyforinstallation•Simple“push-in”installation•Re-openingonlypossiblewithascrewdriver•Integratedsealinglipinthreadflange•Goodpull-outstrength•CompatibelwithallPMAconduitsseries
Conduits:•SuitableforallPMAfittingseries: PMA Smart Line, PMAFIX, EMC System and PMA Divisible System
PMA Smart Line articles are RoHS and WEEE compliant.
If PMA products are used in combination with non PMA products, all product liability claims will be rejected.
Verschraubungen:•Einteilig–montagefertig•EinfacheEinstossmontage•ÖffnungnurmitdemSchraubenziehermöglich•IntegrierteDichtlippegewindeseitig•HoheAusreissfestigkeit•KompatibelmitallenPMA-Wellrohren
Wellrohre:•PassendzuallenPMA-VerschraubungenderSerien: PMA Smart Line, PMAFIX, EMV System und PMA teilbares System
PMA Smart Line-Artikel sind RoHS-und WEEE-konform.
Jegliche Produktehaftung bezüglich der System eigenschaften erlischt, wenn das PMA-System mit Fremdprodukten kombiniert wird.
Functional and modern design with highest quality at an excellent price
Funktionelles und modernes Design bei höchster Qualität zu ausgezeichnetem Preis
Size Codes / Grössen-Codierungen
Table 1 Tabelle 1
PMA Conduit Codes PMA Rohr-Codierungen
Nominal Width Nennweite
Metric Sizes Metrische Grössen
PMA Code
7 10 M10 12 012 16 217 20 723 25 329 32 936 40 648 50 8
Table 2 Tabelle 2
Thread Codes Gewinde-Codierungen
Thread Metric Metrisches Gewinde
PMACode
M12x1.5 M12M16x1.5 M16M20x1.5 M20M25x1.5 M25M32x1.5 M32M40x1.5 M40M50x1.5 M50M63x1.5 M63
Thread PG PG Gewinde
PMACode
PG07 P07
PG09 P09
PG11 P11
PG13.5 P13
PG16 P16
PG21 P21
PG29 P29
PG36 P36
PG48 P48
114
Connectors / Anschlüsse
PMA Smart Line Installation / Montage
• OnepieceFittingwithintegralconeseal• IP66staticandIP54dynamic• Easy“push-in”installation• Fitsconduitswithcoarse(G)andfine(T)profiles• Excellentpull-outstrength• Re-openingforsafetyreasonsonlypossible with a screwdriver
• EinteiligeAnschlussarmaturmitintegrierterKonusdichtung• IP66statischundIP54dynamisch• EinfacheEinstossmontage• VerwendbarfürRohremitGrob-undFeinprofil(TundG)• AusgezeichneteAusreissfestigkeit• ÖffnungzurSicherheitnurmiteinem Schraubenzieher möglich
IP66 static and IP54 dynamic / IP66 statisch und IP54 dynamisch IP66Patent / Patentiert
Installation IP66 / Montage IP66
A. ConduitB. Fitting
A. WellrohrB. Anschlussarmatur
To disengage the locking mechanism introduce a size 1 screwdriver parallel to the conduit into the opening shown in the detail drawing.
Zum Entriegeln Schraubenzieher Gr. 1 parallel zum Rohr in den Öffnungsschlitz beim Rohraustritt stecken.
Push in the conduit (A) with a slight twist until the stop.
Einstossmontage des Wellrohres (A) mit leichter Drehbewegung. Rohr bis zum Anschlag einstossen.
Pull back the conduit (A) slightly to ensure the locking mechanism is fully engaged.
Wellrohr (A) leicht zurückziehen, damit die Verriege-lungselemente optimal einrasten.
A
B
A
A
B
1 2
3 4
A. ConduitB. Fitting
A. WellrohrB. Anschlussarmatur
To disengage the locking mechanism introduce a size 1 screwdriver parallel to the conduit into the opening shown in the detail drawing.
Zum Entriegeln Schraubenzieher Gr. 1 parallel zum Rohr in den Öffnungsschlitz beim Rohraustritt stecken.
Push in the conduit (A) with a slight twist until the stop.
Einstossmontage des Wellrohres (A) mit leichter Drehbewegung. Rohr bis zum Anschlag einstossen.
Pull back the conduit (A) slightly to ensure the locking mechanism is fully engaged.
Wellrohr (A) leicht zurückziehen, damit die Verriege-lungselemente optimal einrasten.
A
B
A
A
B
1 2
3 4
A. ConduitB. Fitting
A. WellrohrB. Anschlussarmatur
To disengage the locking mechanism introduce a size 1 screwdriver parallel to the conduit into the opening shown in the detail drawing.
Zum Entriegeln Schraubenzieher Gr. 1 parallel zum Rohr in den Öffnungsschlitz beim Rohraustritt stecken.
Push in the conduit (A) with a slight twist until the stop.
Einstossmontage des Wellrohres (A) mit leichter Drehbewegung. Rohr bis zum Anschlag einstossen.
Pull back the conduit (A) slightly to ensure the locking mechanism is fully engaged.
Wellrohr (A) leicht zurückziehen, damit die Verriege-lungselemente optimal einrasten.
A
B
A
A
B
1 2
3 4
A. ConduitB. Fitting
A. WellrohrB. Anschlussarmatur
To disengage the locking mechanism introduce a size 1 screwdriver parallel to the conduit into the opening shown in the detail drawing.
Zum Entriegeln Schraubenzieher Gr. 1 parallel zum Rohr in den Öffnungsschlitz beim Rohraustritt stecken.
Push in the conduit (A) with a slight twist until the stop.
Einstossmontage des Wellrohres (A) mit leichter Drehbewegung. Rohr bis zum Anschlag einstossen.
Pull back the conduit (A) slightly to ensure the locking mechanism is fully engaged.
Wellrohr (A) leicht zurückziehen, damit die Verriege-lungselemente optimal einrasten.
A
B
A
A
B
1 2
3 4
115For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
Metric, Polyamide / Metrisch, Polyamid PMA Smart Line
LND straight, metric / gerade, metrisch
LAD 45° elbow, metric / 45° Winkel, metrisch
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
ALND-M120 SLND-M120 M12x1.5 10 12 11.0 34.0 ALND-M160 SLND-M160 M16x1.5 10 12 11.0 34.0 ALND-M162 SLND-M162 M16x1.5 12 16 11.0 38.0 ALND-M200 SLND-M200 M20x1.5 10 12 11.0 34.0 ALND-M202 SLND-M202 M20x1.5 12 16 11.0 38.0 ALND-M207 SLND-M207 M20x1.5 17 20 11.0 41.0 ALND-M257 SLND-M257 M25x1.5 17 20 12.0 42.0 ALND-M253 SLND-M253 M25x1.5 23 25 12.0 45.5 ALND-M323 SLND-M323 M32x1.5 23 25 15.0 48.5 ALND-M329 SLND-M329 M32x1.5 29 32 15.0 50.5 ALND-M409 SLND-M409 M40x1.5 29 32 19.0 54.5 ALND-M406 SLND-M406 M40x1.5 36 40 19.0 60.5 ALND-M506 SLND-M506 M50x1.5 36 40 19.0 61.0 ALND-M508 SLND-M508 M50x1.5 48 50 19.0 61.0 ALND-M638 SLND-M638 M63x1.5 48 50 19.0 61.0
ALAD-M120 SLAD-M120 M12x1.5 10 12 11.0 42.5 x 33.0 ALAD-M160 SLAD-M160 M16x1.5 10 12 11.0 42.5 x 35.0 ALAD-M162 SLAD-M162 M16x1.5 12 16 11.0 47.5 x 39.5 ALAD-M202 SLAD-M202 M20x1.5 12 16 11.0 47.5 x 41.5 ALAD-M207 SLAD-M207 M20x1.5 17 20 11.0 54.0 x 46.0 ALAD-M257 SLAD-M257 M25x1.5 17 20 12.0 55.0 x 48.5 ALAD-M253 SLAD-M253 M25x1.5 23 25 12.0 63.5 x 55.5 ALAD-M323 SLAD-M323 M32x1.5 23 25 15.0 67.0 x 60.0 ALAD-M329 SLAD-M329 M32x1.5 29 32 15.0 72.5 x 63.5 ALAD-M409 SLAD-M409 M40x1.5 29 32 19.0 76.5 x 66.5 ALAD-M406 SLAD-M406 M40x1.5 36 40 19.0 87.5 x 78.0 ALAD-M506 SLAD-M506 M50x1.5 36 40 19.0 88.0 x 82.0 ALAD-M508 SLAD-M508 M50x1.5 48 50 19.0 97.5 x 88.0 ALAD-M638 SLAD-M638 M63x1.5 48 50 19.0 97.5 x 94.5
Order No. IP66 black
Order No. IP66 grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A)
Order No. IP66 black
Order No. IP66 grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A+B)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A+B)
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
patent / patentiert
patent / patentiert
116 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PMA Smart Line MetricandPG,Polyamide/Metrisch und PG, Polyamid
LND straight, PG / gerade, PG
LWD 90° elbow, metric / 90° Winkel, metrisch
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
*ALND-P070 *SLND-P070 7 10 12 7.0 44.0 ALND-P090 SLND-P090 9 10 12 11.0 34.0 *ALND-P092 *SLND-P092 9 12 16 8.0 50.0 ALND-P110 SLND-P110 11 10 12 8.0 45.5 ALND-P112 SLND-P112 11 12 16 11.0 38.0 ALND-P132 SLND-P132 13.5 12 16 11.0 38.0 ALND-P137 SLND-P137 13.5 17 20 11.0 41.0 ALND-P167 SLND-P167 16 17 20 11.0 41.0 ALND-P213 SLND-P213 21 23 25 12.0 45.5 ALND-P299 SLND-P299 29 29 32 12.0 47.5 ALND-P366 SLND-P366 36 36 40 13.0 54.5 ALND-P488 SLND-P488 48 48 50 13.0 55.0
ALWD-M120 SLWD-M120 M12x1.5 10 12 11.0 33.0 x 36.5 ALWD-M160 SLWD-M160 M16x1.5 10 12 11.0 33.0 x 38.5 ALWD-M162 SLWD-M162 M16x1.5 12 16 11.0 37.5 x 43.0 ALWD-M202 SLWD-M202 M20x1.5 12 16 11.0 37.5 x 45.0 ALWD-M207 SLWD-M207 M20x1.5 17 20 11.0 42.0 x 50.5 ALWD-M257 SLWD-M257 M25x1.5 17 20 12.0 43.0 x 53.0 ALWD-M253 SLWD-M253 M25x1.5 23 25 12.0 52.5 x 59.0 ALWD-M323 SLWD-M323 M32x1.5 23 25 15.0 56.0 x 62.5 ALWD-M329 SLWD-M329 M32x1.5 29 32 15.0 62.5 x 69.0 ALWD-M409 SLWD-M409 M40x1.5 29 32 19.0 66.5 x 72.0 ALWD-M406 SLWD-M406 M40x1.5 36 40 19.0 76.0 x 83.0 ALWD-M506 SLWD-M506 M50x1.5 36 40 19.0 76.0 x 87.0 ALWD-M508 SLWD-M508 M50x1.5 48 50 19.0 89.0 x 92.5 ALWD-M638 SLWD-M638 M63x1.5 48 50 19.0 89.0 x 99.0
Order No. IP66 black
Order No. IP66 grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A)
Order No. IP66 black
Order No. IP66 grey
Threadmetric
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A+B)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
Gewindemetrisch
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A+B)
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
* = on request /aufAnfrage
patent / patentiert
patent / patentiert
117For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Connectors / Anschlüsse
PG,Polyamide/PG, Polyamid PMA Smart Line
LWD 90° elbow, PG / 90° Winkel, PG
LAD 45° elbow, PG / 45° Winkel, PG
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
•Formachinebuilding,installationandconstruction industries.
•FürdenMaschinen-undApparatebausowieinder Installationstechnik
*ALWD-P070 *SLWD-P070 7 10 12 7.0 42.0 x 37.5 ALWD-P090 SLWD-P090 9 10 12 11.0 32.5 x 37.5
*ALWD-P092 *SLWD-P092 9 12 16 8.0 48.0 x 43.5 *ALWD-P110 SLWD-P110 11 10 12 8.0 44.0 x 40.0 ALWD-P112 SLWD-P112 11 12 16 11.0 36.5 x 43.5
*ALWD-P130 *SLWD-P130 13.5 10 12 9.0 37.5 x 40.0 ALWD-P132 SLWD-P132 13.5 12 16 11.0 36.5 x 45.0 ALWD-P137 SLWD-P137 13.5 17 20 11.0 41.0 x 50.5 ALWD-P167 SLWD-P167 16 17 20 11.0 41.0 x 51.5 ALWD-P213 SLWD-P213 21 23 25 12.0 52.0 x 61.0 ALWD-P299 SLWD-P299 29 29 32 12.0 58.5 x 70.5 ALWD-P366 SLWD-P366 36 36 40 13.0 70.0 x 85.0 ALWD-P488 SLWD-P488 48 48 50 13.0 83.0 x 97.5
ALAD-P090 SLAD-P090 9 10 12 11.0 42.5 x 34.0 ALAD-P112 SLAD-P112 11 12 16 11.0 47.5 x 40.0 ALAD-P132 SLAD-P132 13.5 12 16 11.0 47.5 x 41.5 ALAD-P137 SLAD-P137 13.5 17 20 11.0 54.0 x 46.0 ALAD-P167 SLAD-P167 16 17 20 11.0 54.0 x 47.0 ALAD-P213 SLAD-P213 21 23 25 12.0 63.5 x 57.5 ALAD-P299 SLAD-P299 29 29 32 12.0 69.5 x 65.0 ALAD-P366 SLAD-P366 36 36 40 13.0 81.5 x 80.0 ALAD-P488 SLAD-P488 48 48 50 13.0 91.5 x 93.0
Order No. IP66 black
Order No. IP66 grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A+B)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A+B)
Order No. IP66 black
Order No. IP66 grey
ThreadPG
Fits to conduit sizeNW metric
Threadlength (g)
Overalllength (A+B)
Bestell-Nr.IP66schwarz
Bestell-Nr.IP66grau
GewindePG
Passend zu RohrgrösseNW metrisch
Gewinde- länge (g)
Gesamt-länge (A+B)
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
• Speciallymodifiedpolyamide• IP66–One-piecefittingwithintegralconeseal• Self-extinguishing• Freefromhalogensandcadmium• Excellentimpactstrength• Temperaturerange: –45 °C to +105 °C; Short-term to +150 °C• Contentofdelivery:Fitting body with preinstalled retaining elements
• SpeziellmodifiziertesPolyamid• IP66 einteilige Anschlussarmatur mit integrierter Konusdichtung• Selbstverlöschend• Halogen-undcadmiumfrei• HervorragendeSchlagfestigkeit• Temperaturbereich: –45 °C bis +105 °C; Kurzzeitig bis +150 °C• Lieferumfang: Verschraubungskörper mit eingerasteten Sperrenelementen
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
* = these products will be delivered with a thread adapter dieseProduktewerdenmitGewindeadaptergeliefert
patent / patentiert
patent / patentiert
118 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Plastic Braided Hoses / Kunststoff-Geflechte
PMAJACK
F.66 Braided hose / Geflechtschlauch•Intheindustry,aviation,constructionofvehiclesand railways
•InderIndustrie,Luftfahrt,Fahrzeug-undBahnbau
F.66.03SW F.66.03GR 3 – 0.3 kg 2.0 5.0F.66.04SW F.66.04GR 4 – 0.4 kg 3.0 7.0F.66.06SW F.66.06GR 6 SRER-06 0.6 kg 5.0 8.0F.66.08SW F.66.08GR 8 SRER-06 0.8 kg 7.0 10.0F.66.10SW F.66.10GR 10 SRER-06 1.0 kg 9.0 13.0F.66.12SW F.66.12GR 12 SRER-06 1.4 kg 11.0 16.0F.66.16SW F.66.16GR 16 SRER-16 1.7 kg 15.0 21.0F.66.20SW F.66.20GR 20 SRER-16 2.0 kg 20.0 26.0F.66.25SW F.66.25GR 25 SRER-21 / SRER-29 2.4 kg 24.0 31.0F.66.30SW F.66.30GR 30 SRER-21 / SRER-29 3.5 kg 28.0 38.0F.66.40SW F.66.40GR 40 SRER-29 4.2 kg 38.0 49.0F.66.50SW F.66.50GR 50 SREV-40 / SRER-50 5.1 kg 48.0 65.0F.66.70SW F.66.70GR 70 SREV-40 / SRER-50 4.9 kg 48.0 85.0
Order No.black
Order No.grey
NW Fits to termination
Weight nom.per 100 m
Operative Rangemin. Ø
Operative Rangemax. Ø
Bestell-Nr.schwarz
Bestell-Nr.grau
NW Passend zuEndabschluss
Gewicht nom.pro 100 m
Einsatzbereichmin. Ø
Einsatzbereichmax. Ø
•Highgrade,speciallymodifiedPolyamidePA6.6•Surfacecoverage:>90%•Flammability:UL94V2•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), UL-File E 125 619, EN45545-2 HL3•Design:followingDIN65164part1+2•MonofileØ:0.28mmforincreasedabrasionproperties•Temperaturerange:–55 °C to +135 °C (UL +125 °C) Short-term:+160°C
•Hochwertiges,speziellmodifiziertesPolyamidPA6.6•Oberflächendeckung:>90%•Brandverhalten:UL94V2•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), UL-FileE125619,EN45545-2HL3•Geflechtskonstruktionangelehntan:DIN65164Teil1+2•MonofilØ:0.28mmfürerhöhteAbriebeigenschaften•Temperaturbereich:–55°Cbis+135°C(UL+125°C) Kurzzeitig:+160°C
Dimensions / Dimensionen in mm
Polyamide and polyester braids – an alternative way to bundle and protect electrical cable.
Applications: mechanicalcableprotection
Installation: simple,practicalinstallation, excellent termination
Standardcolours: blackandgrey
Kunststoffgeflechte aus Polyamid und Polyester – die andere Lösung um elektrische Kabel zu bündeln und zu schützen.
Anwendungen: mechanischerKabelschutz
Montage: einfache,praxisgerechteMontagefür saubere Abschlüsse
Standardfarben: schwarzundgrau
Braided Protection Geflochtener Schutz
119For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Plastic Braided Hoses / Kunststoff-Geflechte
PMAJACK
L.66 Braided hose / Geflechtschlauch
C.66 Braided hose / Geflechtschlauch
F.PX Braided hose / Geflechtschlauch
•Intheindustrialandautomobilesectors. •InderIndustrieundFahrzeugtechnik
•Intheindustrialandautomobilesectors. •InderIndustrieundFahrzeugtechnik
•Intheindustrialandautomobilesectors. •InderIndustrieundFahrzeugtechnik
L.66.04SW L.66.04GR 4 – 0.4 kg 4.0 5.0L.66.08SW L.66.08GR 8 SRER-06 0.5 kg 5.0 10.0L.66.10SW L.66.10GR 10 SRER-06 0.8 kg 7.0 13.0L.66.16SW L.66.16GR 16 SRER-16 0.9 kg 11.0 20.0L.66.20SW L.66.20GR 20 SRER-16 1.4 kg 17.0 33.0L.66.25SW L.66.25GR 25 SRER-21 / SRER-29 1.5 kg 21.0 34.0L.66.30SW L.66.30GR 30 SRER-21 / SRER-29 1.8 kg 25.0 45.0L.66.40SW L.66.40GR 40 SRER-29 1.9 kg 31.0 55.0L.66.50SW L.66.50GR 50 SREV-40 / SRER-50 3.2 kg 58.0 70.0
C.66.10SW C.66.10GR 10 SRER-06 0.7 kg 8.0 14.0 C.66.12SW C.66.12GR 12 SRER-06 / SRER-16 0.9 kg 9.0 18.0 C.66.16SW C.66.16GR 16 SRER-06 / SRER-16 1.2 kg 11.0 22.0 C.66.20SW C.66.20GR 20 SRER-16 / SRER-21 1.4 kg 14.0 26.0 C.66.25SW C.66.25GR 25 SRER-16 / SRER-21 1.4 kg 18.0 28.0 C.66.30SW C.66.30GR 30 SRER-21 / SRER-29 2.5 kg 25.0 43.0 C.66.40SW C.66.40GR 40 SRER-29 2.5 kg 30.0 52.0 C.66.45SW – 45 SREV-40 / SRER-50 4.0 kg 40.0 73.0
F.PX.04GR 04 – 0.3 kg 3.0 7.0 F.PX.06GR 06 SRER-06 0.5 kg 5.0 8.0 F.PX.08GR 08 SRER-06 0.7 kg 7.0 10.0 F.PX.10GR 10 SRER-06 0.8 kg 9.0 13.0 F.PX.12GR 12 SRER-06 1.1 kg 11.0 16.0 F.PX.16GR 16 SRER-16 1.3 kg 15.0 21.0 F.PX.20GR 20 SRER-16 / SRER-21 1.5 kg 20.0 26.0 F.PX.25GR 25 SRER-16 / SRER-21 2.0 kg 24.0 31.0 F.PX.30GR 30 SRER-21 / SRER-29 2.9 kg 28.0 38.0 F.PX.40GR 40 SREV-40 3.1 kg 38.0 49.0
Order No.black
Order No.grey
NW Fits to termination
Weight nom.per 100 m
Operative Rangemin. Ø
Operative Rangemax. Ø
Bestell-Nr.schwarz
Bestell-Nr.grau
NW Passend zuEndabschluss
Gewicht nom.pro 100 m
Einsatzbereichmin. Ø
Einsatzbereichmax. Ø
Order No.black
Order No.grey
NW Fits to termination
Weight nom.per 100 m
Operative Rangemin. Ø
Operative Rangemax. Ø
Bestell-Nr.schwarz
Bestell-Nr.grau
NW Passend zuEndabschluss
Gewicht nom.pro 100 m
Einsatzbereichmin. Ø
Einsatzbereichmax. Ø
Order No.grey
NW Fits to termination
Weight nom.per 100 m
Operative Rangemin. Ø
Operative Rangemax. Ø
Bestell-Nr.grau
NW Passend zuEndabschluss
Gewicht nom.pro 100 m
Einsatzbereichmin. Ø
Einsatzbereichmax. Ø
•Highgrade,speciallymodifiedPolyamidePA6.6•Surfacecoverage:>65%•Flammability:UL94V2•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2 HL3•Design:followingDIN65164part1+2•MonofileØ:0.25mm•Temperaturerange:–55°Cto+135°C;Short-term:+160°C
•Hochwertiges,speziellmodifiziertesPolyamidPA6.6•Oberflächendeckung:>65%•Brandverhalten:UL94V2•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2HL3•Geflechtskonstruktionangelehntan:DIN65164Teil1+2•MonofilØ:0.25mm•Temperaturbereich:–55°Cbis+135°C;Kurzzeitig:+160°C
•Highgrade,speciallymodifiedPolyamidePA6.6•Surfacecoverage:>75%•Flammability:UL94V2•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2 HL3•Design:followingDIN65164part1+2•MonofileØ:0.28mmforincreasedabrasionproperties•Temperaturerange:–55°Cto+135°C;Short-term:+160°C
•Hochwertiges,speziellmodifiziertesPolyamidPA6.6•Oberflächendeckung:>75%•Brandverhalten:UL94V2•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2HL3•Geflechtskonstruktionangelehntan:DIN65164Teil1+2•MonofilØ:0.28mmfürerhöhteAbriebeigenschaften•Temperaturbereich:–55°Cbis+135°C;Kurzzeitig:+160°C
•Polyester•Surfacecoverage:>90%•Flammability:UL94V0•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I1/F2), EN45545-2 HL3•Design:followingDIN65164part1+2•MonofileØ:0.28mmforincreasedabrasionproperties•Temperaturerange:–50°Cto+120°C;Short-term:+150°C
•Polyester•Oberflächendeckung:>90%•Brandverhalten:UL94V0•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I1/F2), EN45545-2HL3•Geflechtskonstruktionangelehntan:DIN65164Teil1+2•MonofilØ:0.28mmfürerhöhteAbriebeigenschaften•Temperaturbereich:–50°Cbis+120°C;Kurzzeitig:+150°C
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
120 For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Plastic Braided Hoses / Kunststoff-Geflechte
PMAJACK
L.PX Braided Hose / Geflechtschlauch
G.PX Open braided hose / offener Geflechtschlauch
HSG Hot cutting tool / Heiss-Schneidegerät
•Intheindustrialandautomobilesectors •InderIndustrieundFahrzeugtechnik
•Usedinawiderangeofapplications •IneinembreitenAnwendungsgebietverwendet
•Smallesthotcuttingtoolforpermanentusewithfixededge (working area 30 mm) for a quick and easy cutting of plastic braidings
•KleinstesHeiss-SchneidegerätfürDauerbetriebmitfestste- henderSchneide(Arbeitsbereich30mm),zumschnellen und sauberen Ablängen von Kunststoffgeflechtschläuchen.
L.PX.04SW L.PX.04GR 04 – 0.4 kg 3.0 8.0L.PX.08SW L.PX.08GR 08 SRER-06 0.5 kg 5.0 10.0L.PX.10SW L.PX.10GR 10 SRER-06 0.7 kg 7.0 14.0L.PX.16SW L.PX.16GR 16 SRER-16 0.8 kg 11.0 20.0L.PX.20SW L.PX.20GR 20 SRER-16 1.2 kg 19.0 28.0L.PX.25SW L.PX.25GR 25 SRER-21 / SRER-29 1.4 kg 21.0 34.0L.PX.30SW L.PX.30GR 30 SRER-21 / SRER-29 1.7 kg 25.0 40.0L.PX.40SW L.PX.40GR 40 SRER-29 1.7 kg 31.0 55.0L.PX.50SW L.PX.50GR 50 SREV-40 / SRER-50 2.7 kg 40.0 68.0
G.PX.05SW 05 25 1.6 kg 4.5 5.5 G.PX.08SW 08 25 2.0 kg 7.0 9.0 G.PX.10SW 10 25 2.3 kg 9.0 11.0 G.PX.13SW 13 25 2.5 kg 11.5 13.0 G.PX.16SW 16 25 3.4 kg 14.5 17.5 G.PX.19SW 19 25 3.8 kg 17.0 21.0 G.PX.25SW 25 25 4.8 kg 22.5 27.5 G.PX.29SW 29 25 5.3 kg 26.0 32.0G.PX.32SW 32 25 6.1 kg 29.0 35.0 G.PX.38SW 38 25 8.3 kg 34.0 42.0 G.PX.50SW 50 25 8.7 kg 45.0 55.0
HSG-00 HSG-00-SB
Order No.black
Order No.grey
NW Fits to termination
Weight nom.per 100 m
Operative Rangemin. Ø
Operative Rangemax. Ø
Bestell-Nr.schwarz
Bestell-Nr.grau
NW Passend zuEndabschluss
Gewicht nom.pro 100 m
Einsatzbereichmin. Ø
Einsatzbereichmax. Ø
Order No.black
NW Packing unitPU/m
Weight nom.per 100 m
Recommended Range min. Ø max. Ø
Bestell-Nr.schwarz
NW Verp.-EinheitVE/m
Gewicht nom.pro 100 m
Einsatzbereich min. Ø max. Ø
Order No.Hot Cutting Tool
Order No.Spare Cutting Tape
Bestell-Nr.Heiss-Schneidegerät
Bestell-Nr.Ersatz-Schneidband
•Polyester•Surfacecoverage:>65%•Flammability:UL94V0•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I1/F2), EN45545-2 HL3•Design:followingDIN65164part1+2•MonofileØ:0.22mm•Temperaturerange:–50°Cto+120°C;Short-term:+150°C
•Polyester•Oberflächendeckung:>65%•Brandverhalten:UL94V0•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I1/F2), EN45545-2HL3•Geflechtskonstruktionangelehntan:DIN65164Teil1+2•MonofilØ:0.22mm•Temperaturbereich:–50°Cbis+120°C;Kurzzeitig:+150°C
•Polyester•Overlapping:90°(+40°/–25°)•Flammability:UL94V0•Specifications:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2 HL3•Temperaturerange:–55 °C to +150 °C
•Polyester•Überlappungsgrad:90°(+40°/–25°)•Brandverhalten:UL94V0•Zulassungen:DIN5510(S4/SR2/ST2),NFF16-101/102(I3/F2), EN45545-2HL3•Temperaturbereich: –55 °C bis +150 °C
•Material:Metal•Tension:230V-50Hz(115V-60Hz)•Performance:40W•Lengthoftheconnectinglead:2m
•Material:Metall•Netzspannung:230V-50Hz(115V-60Hz)•Aufnahmeleistung:40W•LängederAnschlussleitung:2m
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
121For other sizes please contact your nearest PMA distribution partner or PMA headquarters. / Für andere Grössen kontaktieren Sie bitte Ihre nächste PMA-Vertretung oder PMA Schweiz.
Plastic Braided Hoses / Kunststoff-Geflechte
PMAJACK
RER/REV PMAJACK Termination / PMAJACK Endabschluss
REIR PMAJACK Polyamide female thread adapter PMAJACK Polyamid Innengewindeadapter
MREIR PMAJACK metal female thread adapter PMAJACK Metall Innengewindeadapter
•Forawiderangeofapplications •FüreinbreitesAnwendungsgebiet
•Forawiderangeofapplications •FüreinbreitesAnwendungsgebiet
•Forawiderangeofapplications •FüreinbreitesAnwendungsgebiet
SRER-06 (x) 06 0.2 kg 6.5 13 – – 13 21 33 13 6SRER-16 (x) 16 0.6 kg 16 24 – – 15 25 39 15 7SRER-21 (x) 21 1.1 kg 22 32 – – 20 29 43 15 7
SRER-29 (z) 29 1.5 kg 30 40 – – 18 29 43 39 7SRER-50 (z) 50 2.4 kg 50 61 – – 18 29 43 50 7
SREV-40 (y) 40 2.1 kg 47 58 34 44 20 24 44 38 10
BREIR-U2916 16 12-20 12-25 16-25 0.7 kg 36.2 20.5 10.5 36.5 9 15 25BREIR-U3516 16 12-20 12-25 16-25 0.9 kg 42.5 20.5 11.5 37.5 9 15 25
MREIR-U3529 29 25-40 30+40 25-40 0.7 kg 29 40.0 40.5 37.5 30.0
Order No.grey
NW Weight nom.per 100 pcs
Bestell-Nr.grau
NW Gewicht nom.pro 100 Stück
Order No.black
NW Fits to PMAJACK
Weight nom.per 100 pcs
Bestell-Nr.schwarz
NW Passend zuPMAJACK
Gewicht nom.pro 100 Stück
Order No.black
NW Fits to PMAJACK
Weight nom.per 100 pcs
Bestell-Nr.schwarz
NW Passend zuPMAJACK
Gewicht nom.pro 100 Stück
F.66 C.66F.PX
L.66L.PX
F.66 C.66 F.PX
•Highgrade,speciallymodifiedpolyamide6•Systembelongingto:PMAJACKF.66,C.66,L.66,F.PX,L.PX•Version:typeRER=roundversion/type REV = rectangular version•Temperaturerange:–40 °C to +105 °C Short-term:+160°C
•Hochwertiges,speziellmodifiziertesPolyamid6•Systemzugehörigkeit:PMAJACKF.66,C.66,L.66,F.PX,L.PX•Versionen:TypRER=rundeAusführung/ TypREV=rechteckigeAusführung•Temperaturbereich: –40 °C bis +105 °C Kurzzeitig:+160°C
•Highgrade,speciallymodifiedpolyamide6•Temperaturerange:–40°Cto+105°C;Short-term:+160°C•Systembelongingto:PMAJACKF.66,C.66,L.66,F.PX,L.PX
•Hochwertiges,speziellmodifiziertesPolyamid6•Temperaturbereich:–40°Cbis+105°C;Kurzzeitig:+160°C•Systemzugehörigkeit:PMAJACKF.66,C.66,L.66,F.PX,L.PX
•Femalethreadadaptersaremadeofblackanodisedaluminium, clampingringismadeofspeciallymodifiedPolyamide6•Temperaturerange:–40°Cto+105°C;Short-term:+160°C•Systembelongingto:PMAJACKF.66,C.66,L.66,F.PX,L.PX
•Innengewinde-AdapterausschwarzemeloxiertenAluminium, KlemmringausspeziellmodifiziertemPolyamid6•Temperaturbereich:–40°Cbis+105°C;Kurzzeitig:+160°C•Systemzugehörigkeit:PMAJACKF.66,C.66,L.66,F.PX,L.PX
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
Dimensions / Dimensionen in mm
AI AA BI BA H L G S C
Ø D1 Ø ID B G g H Ø D2
g Ø D1 Ø D2 L Ø ID
*ForexactbraidandterminationfittingconfigurationpleaserefertoPMAJACKdatasheets*FürdiegenaueGeflechtzuordnungsiehePMAJACK-Datenblätterx = with one mounting hole / mit Ein-Loch-Befestigungy = with two mounting holes / mit Zwei-Loch-Befestigungz = with three mounting holes / mit Drei-Loch-Befestigung
*ForexactbraidandterminationfittingconfigurationpleaserefertoPMAJACKdatasheets*FürdiegenaueGeflechtzuordnungsiehePMAJACKDatenblätter
*ForexactbraidandterminationfittingconfigurationpleaserefertoPMAJACKdatasheets*FürdiegenaueGeflechtzuordnungsiehePMAJACKDatenblätter
RER
(X)
REV
(Y)
RER
(Z)
BREIR
MREIR
Technical Annex / Technischer Anhang
Testing Methods / Prüfmethoden
122
Conformance withStandards:
Additional Services to Benefit you
PMA products conform to worldwide standards and regulations. As a pioneer in the field of cable protec-tion, we have al ways given high priority to our own testing facilities, and we have consciously introduced stringent in-house standards. This approach has enabled PMA AG to exercise a significant influence on the development of international stan-dards. Standards committees with res-ponsibility for cable systems regularly ask our company to provide advice or partici-pate as an active member.
High Quality Product from A – Z
From basic items to high-tech products, all of our products meet the most strin gent quality requirements. Some of the outstanding are:
• resistance to temperature, weathering, UV radiation, and chemical agents
• high system pull-out resistance
• excellent fire protection characteristics (flammability, smoke density, and toxicity)
• excellent system ingress protection up to IP68 and IP69K
• extremely long service life
• conformance to the EN ISO 9001:2000 quality standard
Normsicherheit:
Zusatzleistungen zum Profitieren
PMA-Produkte erfüllen weltweit aner-kannte Normen und Richtlinien. Als Pionier im Kabelschutz legen wir seit jeher grossen Wert auf die Durchführung eigener Prüfungsverfahren, wobei die Massstäbe von uns bewusst sehr hoch angesetzt werden. Mit dieser Arbeitsweise hat die PMA AG die Ent wicklung internati-onaler Standards massgeblich beeinflusst und geprägt. Unser Unter nehmen wird deshalb von Normierungsausschüssen von Kabelschutzsystemen regelmässig als Berater oder Aktivmitglied beigezogen.
Qualitätsprodukt von A – Z
Vom Basis- bis zum High-Tech-Produkt – alle unsere Artikel entsprechen den höchs ten Qualitätsanforderungen. Sie zeichnen sich speziell aus durch:
• Beständigkeit gegenüber Temperaturen, Witterung, UV-Strahlen und chemischen Einflüssen
• hohe System-Ausreissfestigkeit
• optimales Brandschutzverhalten hinsichtlich Brandeigenschaften, Rauchgasdichte und –toxizität
• ausgezeichnete Systemdichtheit bis IP68 und IP69K
• extrem hohe Lebensdauer
• Qualitätsstandard nach EN ISO 9001:2000
123
Technical Annex / Technischer Anhang
Testing Methods / Prüfmethoden
Testing Methods
Reversed Bending Test with Swinging Movements
This standard is based on a cyclic rever-sed bending test (pivoting) of conduits under various conditions (temperature). The conduits are dynamically loaded and evaluated at the upper and lower appli-cation temperature limits. The test is performed based on IEC EN 61386. The minimum requirement corresponds to the specifications of IEC EN 61386. For PMA, the test is not considered completed for final evaluation until cracking or fracture. The number of cycles to fracture determi-nes the fatigue strength of the conduit.
Reversed Bending Test
This standard describes a cyclic rever-sed bending test with additional tensile loading (lifting) on flexible conduits under standard ambient conditions (23°C/50% relative humidity). The conduit is loaded until fracture. The number of cycles to fracture determines the fatigue strength of the conduit.
Reversed Bending Test
This standard describes a cyclic bending test (rotation in an oval pattern) on flexib-le conduits under standard ambient con-ditions (23°C/50% relative humidity). The conduit is tested until failure. The number of cycles to fracture determi-nes the fatigue strength of the conduit.
DO 9.21-4425 IEC EN 61386
DO 9.21-4420
DO 9.21-4220
Prüfmethoden
Wechselbelastung mit Schwenkbewegung
Eine Wechselbelastungsprüfung Schwenk-bewegung) flexibler Wellrohre bei unter-schiedlichen Bedingungen (Temperatur) liegt dieser Norm zugrunde. Die Wellroh-re werden bei der unteren und oberen Anwendungstemperatur dynamisch be- lastet und beurteilt. Die Prüfung erfolgt in Anlehnung an IEC EN 61386. Die Mini-malanforderung entspricht den Vorgaben der IEC EN 61386. Zur abschließenden Beurteilung gilt die Prüfung für PMA erst nach Riss oder Bruch als beendet. Die Lastspielzahl bis zum Bruch bestimmt die Wechselbiegefestigkeit des Wellrohres.
Wechselbiegeprüfung
Diese Norm beschreibt eine Wechsel-biegebelastungsprüfung mit zusätzlicher Zugbelastung (Hubbewegung) an flexib-len Wellrohren bei Normklima (23°C / 50% relative Feuchte). Das Rohr wird bis zum Bruch belastet. Die Anzahl Zyklen bis zum Bruch bestimmen die Wechselbiegefestig-keit des Wellrohres.
Wechselbiegeprüfung
Diese Norm beschreibt eine Biege- belastungsprüfung (ovale Kreisbewegung) an flexiblen Wellrohren bei Normklima (23°C / 50% relative Feuchte). Das Rohr wird bis zum Versagen belastet. Die Anzahl Zyklen bis zum Bruch bestim-men die Biegefestigkeit des Wellrohres.
124
Technical Annex / Technischer Anhang
IEC EN 61386 Testing Methods / Prüfmethoden
Testing Methods
Peak Load Test
This standard describes the peak load test on conduits under standard ambient conditions (23°C/50% relative humidity). The conduit is deformed by a defined amount between two plates. The resto-ring force established over a specific time (by relaxation of the conduit) describes the crushing pressure or compressive strength.
Pull Out Test
This standard defines the system pull-out test on conduits and connectors under standard ambient conditions (23°C/50% relative humidity). The conduits are mounted with the appropriate system connectors. The pull-out strength of the system is determined in a tensile test.
Impact Test
This standard describes the impact strength test on conduits at various tem-peratures. The specimen is placed on a steel plate, centred under an impact head with a defined profile. The impact head im-pacts the centre of the specimen surface. In contrast to international specifications, deformation behaviour (buckling) is deter-mining rather than fracture behaviour. The impact test is considered to be passed if no fracture or cracking can be detected after the impact, as well as no excessive permanent deformation of the conduit in accordance with PMA specifications.
DO 9.21-4320IEC EN 61386
DO 9.21-4610 IEC EN 61386
DO 9.21-4330IEC EN 61386
Prüfmethoden
Scheitellastprüfung
Diese Norm beschreibt die Scheitellast-prüfung an Wellrohren bei Normklima (23°C / 50% r. F.). Das Rohr wird zwischen zwei Platten definiert verformt. Die sich über eine bestimmte Zeit einstellende Rückstellkraft (durch Relaxation) des Rohres beschreibt die Scheiteldruck- respektive die Trittfestigkeit.
Systemausreissfestigkeit
Diese Norm definiert die Systemausreisss-prüfung an Wellrohren und Verschrau-bungen bei Normalklima (23°C / 50% r. F.). Die Rohre werden mit den passenden Systemverschraubungen montiert. Im Zugversuch erfolgt die Prüfung der Ausreissfestigkeit des Systems.
Schlagprüfung
Diese Norm beschreibt die Schlagfestigkeits-prüfung an Wellrohren bei unter schiedlichen Temperaturen. Der Prüfkörper liegt auf einer Stahlplatte mittig unter einem definierten Schlagprofil. Das Schlagprofil trifft den Prüf-ling zentrisch auf die Oberfläche. Im Ge-gensatz zu internationalen Spezifikationen ist hierbei nicht nur das Bruchverhalten mass-gebend, sondern das Verformungsverhalten (Beulen). Die Schlag prüfung gilt als bestan-den, wenn nach dem Schlag kein Bruch oder Riss sowie gemäss PMA-Anforderungen keine übermässige, bleibende Verformung des Rohres festzustellen sind.
(EN 50086)
125
Technical Annex / Technischer Anhang
Testing Methods / Prüfmethoden IEC EN 61386
Testing Methods
Cold Bending Test
This standard describes a bending test on conduits at low temperatures. The specimens are stored in a controlled- climate cabinet at the specified test temperature. Loading is achieved by winding the specimen around a test mandrel with a defined diameter. The various products are classified based on the mandrel diameter which can be achieved.
Thermal Ageing Test
This standard describes a bending test on thermally aged specimens. The test con-duits are stored in a controlled-climate oven at the specified test temperature. After removal from the oven, they are cooled to room temperature. Loading is achieved by winding the specimen around a test mandrel with a defined diameter. The various products are classified based on the mandrel diameter which can be achieved.
Self-Extinguishing
This standard describes a flame test on conduits based on international specifica-tions. The conduit is exposed to a defined flame from a standard burner. The time of ignition, flame propagation behaviour as well as time of extinguishing after removal of the flame source are significant parame-ters for evaluating the flame behaviour of the products.
DO 9.21-4380
DO 9.21-4360
DO 9.21-4430IEC EN 61386
Prüfmethoden
Kältewickelprüfung
Diese Norm beschreibt eine Biegeprüfung an Wellrohren bei tiefen Temperaturen. Die Prüflinge werden im Klimaschrank bei vorgegebener Prüftemperatur gela-gert. Die Belastung entsteht durch das Umwickeln eines Prüfdorns mit definier-tem Durchmesser. Entsprechend dem erreichbaren Dorndurchmesser werden die verschiedenen Produkte klassifiziert.
Wärmealterung
Diese Norm beschreibt eine Biegebe-lastungsprüfung an thermisch gealter-ten Prüflingen. Die Testrohre werden im Klimaofen bei vorgegebener Prüftempera-tur gelagert. Nach der Entnahme aus dem Ofen, werden sie auf Raumtemperatur abgekühlt. Die Belastung entsteht durch das Umwickeln eines Prüfdorns mit defi-niertem Durchmesser. Entsprechend dem erreichbaren Dorndurchmesser werden die verschiedenen Produkte klassifiziert.
Selbstverlöschung
Diese Norm beschreibt eine Brandprüfung an Wellrohren in Anlehnung an internati-onale Spezifikationen. Die Rohre werden dabei mit einem definierten Normbrenner beflammt. Der Entzündungszeitpunkt, das Brandausbreitungsverhalten sowie die Verlöschungszeit nach dem Entfernen der Brandquelle sind wesentliche Grössen zur Beurteilung des Brandverhaltens der Bauteile.
(EN 50086)
126
Technical Annex / Technischer Anhang
IEC 60529 Ingress Protection / Schutzart
Ingress Protection (IP)according toEN 60529 / DIN 40050
Ingress Protection (IP)= A standard to classify product performance regarding ingress protection.
Different number –different protection!
For example, products classified as IPx8 are not automatically protected against jet water! Immersion tests for classifications IPx7 and IPx8 differ from the tests for protection against jet water for IPx6, IPx5, or IPx4.Therefore PMA cable protection systems are tested regarding different sealing requirements.
Protection against contact and penetration of foreign objectsDegree of protection (contact/foreign bodies)
Compliance certified by a independent test laboratory. Official approval documents available on request:[email protected]
The first digit stands for: Protection against
Dust
Schutzart (IP) nach EN 60529 / DIN 40050
Schutzart (IP)= Ein Standard zur Klassifizierung der Produkteigenschaften hinsichtlich Schutzart.
Verschiedene Nummern –verschiedener Schutz!
Zum Beispiel sind Produkte mit der IPx8- oder IPx7-Klasse nicht automatisch gegen Strahlwasser geschützt! Eintauchtests für die Klassifikation IPx7 und IPx8 unterschei-den sich von den Tests zum Schutz gegen Strahlwasser IPx6, IPx5 oder IPx4.Daher werden PMA Kabelschutzsysteme nach unterschiedlichen Dichtarten getestet.
Schutz gegen Berühren und Eindringen von FremdkörpernSchutzgrad (Berührung/Fremdkörper)
Die Einhaltung aller Richtlinien werden von einem unabhängigen Testlabor bestätigt. Offizielle Prüf-Dokumente können angefordert werden: [email protected]
Die erste Ziffersteht für:Schutz vor
Staub
PMA products offer complete protection!
PMA Produkte garan tieren kompletten Schutz!
IP68
No protection
Protection against large foreign bodies
Protection against medium foreign bodies
Protection against small foreign bodies
Protection against foreign grains
Dust-protected
Dust-tight
Kein Schutz
Schutz gegen grosse Fremdkörper
Schutz gegen mittel- grosse Fremdkörper
Schutz gegen kleine Fremdkörper
Schutz gegen korn- förmige Fremdkörper
Staubgeschützt
Staubdicht
No contact protection, no protection against solid particles and bodies.
Protection against large contact area with hands and foreign bodies with Ø > 50 mm.
Protection against contact with fingers, pro-tection against foreign bodies Ø > 12.5 mm
Protection against tool contact foreign bodies, wires or the like with Ø > 2.5 mm.
See 3, but Ø > 1 mm.
Full contact protection. Protection against dust deposits inside.
Full contact protection. Protection against dust penetration.
Kein Berührungsschutz,kein Schutz gegen feste Fremdkörper.
Schutz gegen grossflächige Berührung mit der Hand. Schutz gegen Fremdkörper mit Ø > 50 mm.
Schutz gegen Berührung mit den Fingern. Schutz gegen Fremdkörper mit Ø > 12.5 mm.
Schutz gegen Berührung mit Werkzeug, Drähten oder Fremdkörper mit Ø > 2.5 mm.
Wie 3, jedoch Ø > 1 mm.
Vollständiger Schutz gegen Berührung.Schutz gegen Staubablagerung im Innern.
Vollständiger Schutz gegen Berührung. Schutz gegen Eindringen von Staub.
0
1
2
3
4
5
6
0
1
2
3
4
5
6
127
Technical Annex / Technischer Anhang
Ingress Protection / Schutzart IEC 60529
PMA Products
Protection against fluidsDegree of protection (water)
The second digit stands for: Protection against
Water
PMA-Produkte
✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔
✔ ✔ ✔
✔ ✔ ✔
✔ ✔* ✔* ✔* ✔*
Schutz gegen FlüssigkeitenSchutzgrad (Wasserschutz)
Die zweite Ziffersteht für:Schutz vor
Wasser
IP68
No protection
Protection against dripping water
Protection against inclined water drops
Protection against spray-water
Protection against splash-water
Protection against water jets
Protection against powerful water jets
Protection against immersion
Protection against submersion
Protection against high pressure cleaning
Kein Schutz
Schutz gegen Tropfwasser
Schutz gegen schrägfallendes Tropfwasser
Schutz gegenSprühwasser
Schutz gegen Spritzwasser
Schutz gegen Strahlwasser
Schutz gegenstarkes Strahlwasser
Schutz gegen zeitweiliges Eintauchen
Schutz gegen dauern des Untertauchen
Schutz gegen Hochdruck-/ Dampfstrahl-Reinigung
No protection against water.
Protection against vertical water drops.
Protection against inclined water drops (any up to 15° to vertical line).
Protection against spray water from an of 60° to vertical line.
Protection against splash water from all directions.
Protection against water jets from any .
Protection against powerful waterjets from any .
Protection against water penetration 1 m below water.
Protection against pressure water for an indefinite time (customer tailored).
Protection against water from any with high pressure.
Splash water from all directionsSpritzwasser aus allen Richtungen
Jet water at any angleStrahlwasser (Düse) aus allen Richtugen
Powerful jet water from any angleStarkes Strahlwasser aus allen Richtungen
Submersion (1m, 30 min.)Untertauchen (1m, 30 min.)
Submersion at time and pressure >IPx7Untertauchen mit Dauer und Druck >IPx7
High pressure (up to 80 bar) water from any angleWasser aus allen Richtungen unter starkem Druck (bis zu 80 bar)
Kein Wasserschutz.
Schutz gegen senkrecht fallende Wassertropfen.
Schutz gegen schräg fallendes Tropfwasser (beliebiger bis zu 15° zur Vertikalen).
Schutz gegen Sprühwasser aus einem von bis zu 60° zur Senkrechten.
Schutz gegen Spritzwasser aus allen Richtungen.
Schutz gegen Strahlwasser (Düse) aus beliebigem .
Schutz gegen starkes Strahlwasser aus beliebigem .
Schutz gegen Wassereindringung bei vorübergehendem Eintauchen.
Schutz gegen Druckwasser für unbestimmte Zeit.
Schutz gegen Wasser aus beliebigemunter stark erhöhtem Druck.
0
1
2
3
4
5
6
7
8
9K
0
1
2
3
4
5
6
7
8
9K
IPx4
IPx5
IPx6
IPx7
IPx8
IPx9K
* EN 60529 / DIN 40050 can be fulfilled without WPS (Water impact protection ring). PMA recommends the use of the WPS ring for trouble free practical applications.
* EN 60529 / DIN 40050 kann ohne WPS (360° Wasserprallschutzring) erfüllt werden. Für eine praxisgerechte Anwendung empfiehlt PMA jedoch den Gebrauch eines WPS.
PMAFIX Pro PMAFIX PMAFIX PMAFIX PMASMART-LINEIP68 + WPS IP68/IP68GT IP66
128
Technical Annex / Technischer Anhang
Table of Thread Dimension / Gewindetabelle
Thread Dimensions Gewindetabelle
Metric Fine thread
PG Thread
GAS Pipe thread
EN 60423
DIN 40430
DIN 259 Bl. 3ISO 228/I
Metrisches Feingewinde
Stahlpanzerrohr-Gewinde
GAS-Rohrgewinde
55°
Ø D1Ø D2
12 1.5 12 10.16 12.0
16 1.5 16 14.16 16.0
20 1.5 20 18.16 20.0
25 1.5 25 23.16 25.0
32 1.5 32 30.16 32.0
40 1.5 40 38.16 40.0
50 1.5 50 48.16 50.0
63 1.5 63 61.16 63.0
07 1.270 12.5 11.28 12.7
09 1.411 15.2 13.86 15.4
11 1.411 18.6 17.26 18.8
13 1.411 20.4 19.06 20.7
16 1.411 22.5 21.16 22.8
21 1.588 28.3 26.78 28.6
29 1.588 37.0 35.48 37.4
36 1.588 47.0 45.48 47.5
48 1.588 59.3 57.78 59.8
1⁄4 " 1.337 13.157 11.445 13.43⁄8 " 1.337 16.662 14.950 17.01⁄2 " 1.814 20.955 18.631 21.33⁄4 " 1.814 26.441 24.117 26.8
1 " 2.309 33.249 30.291 33.7
1 1⁄4 " 2.309 41.910 38.952 42.4
1 1⁄2 " 2.309 47.803 44.845 48.31
2 " 2.309 59.614 56.656 60.2
PG mm mm mm mm
GAS mm mm mm mm
Metric mm mm mm mm
Pitch Major Ø Minor Ø HoleSteigung Aussen-Ø Kern-Ø Durchgangsbohrung
D1 D2 -0 / +0.3
Pitch Major Ø Minor Ø HoleSteigung Aussen-Ø Kern-Ø Durchgangsbohrung
D1 D2
Pitch Major Ø Minor Ø HoleSteigung Aussen-Ø Kern-Ø Durchgangsbohrung
D1 D2
Pitch Steigung
Pitch Steigung
Pitch Steigung
129
Technical Annex / Technischer Anhang
Table of Thread Dimension / Gewindetabelle
Thread Dimensions
Comparison Table
Inside diameter threads to inside diameter conduits
Gewindetabelle
Vergleichstabelle
Innen-Durchmesser Gewinde zu Innen-Durchmesser Rohre
American Standard Taper Pipe Thread
Connector PG Anschluss PG
NSI B2.1 / ANSI B2.2
ConduitRohr
Amerikanisches kegeliges Rohrgewinde
Connector MetricAnschluss Metrisch
IDIDNW
NW
ID
ID
1⁄4 " 1.411 13.616 13.93⁄8 " 1.411 17.055 17.41⁄2 " 1.814 21.223 21.63⁄4 " 1.814 26.568 26.9
1 " 2.209 33.227 33.7
1 1⁄4 " 2.209 41.984 42.4
1 1⁄2 " 2.209 48.053 48.5
2 " 2.209 60.091 60.6
07 1.270 12.5 11.28 12.7
09 1.411 15.2 13.86 15.4
11 1.411 18.6 17.26 18.8
13 1.411 20.4 19.06 20.7
16 1.411 22.5 21.16 22.8
21 1.588 28.3 26.78 28.6
29 1.588 37.0 35.48 37.4
36 1.588 47.0 45.48 47.5
48 1.588 59.3 57.78 59.8
1⁄4 " 1.337 13.157 11.445 13.43⁄8 " 1.337 16.662 14.950 17.01⁄2 " 1.814 20.955 18.631 21.33⁄4 " 1.814 26.441 24.117 26.8
1 " 2.309 33.249 30.291 33.7
1 1⁄4 " 2.309 41.910 38.952 42.4
1 1⁄2 " 2.309 47.803 44.845 48.31
2 " 2.309 59.614 56.656 60.2
NPT mm mm mm
Pitch Major Ø HoleSteigung Aussen-Ø Durchgangsbohrung
D1 D2 Pitch
Steigung
Tapering Konizität
6.25%
Nominal width Nennweite
NW
Inside diameter Innen-Durchmesser
mm (nom.)ID
Inside diameter Innen-Durchmesser
mm (nom.)ID
Inside diameterInnen-Durchmesser
mm (nom.)ID
Standard Inside Ø Thread size Metal Polyamide Thread size Metal Polyamidenominal thread thread thread thread
Standard Innen Ø Gewinde- Metall- Polyamid- Gewinde- Metall- Polyamid-nominal grösse gewinde gewinde grösse gewinde gewinde
NW07 6.2 PG07 - 8.0 M10 - -NW10 9.6 PG09 9.5 10.0 M12 5.7 8.0
M16 - 11.0NW12 12.0 PG11 12.5 13.0 M16 9.7 11.0
- - PG13.5 14.5 14.5 - - -NW17 16.2 PG16 16.5 17.5 M20 13.7 14.6NW23 22.6 PG21 22.5 22.5 M25 18.6 19.0NW29 29.0 PG29 30.5 30.5 M32 25.7 26.0NW36 36.5 PG36 40.5 37.5 M40 33.4 32.0
- - PG42 - 48.0 - - -NW48 47.5 PG48 52.0 50.0 M50 42.7 42.0
M63 54.0 53.0
130
Technical Annex / Technischer Anhang
Torques / Drehmomente
Recommended torques for PMA fittings
Empfohlene Drehmomente für PMA-Verschraubungen
For Threaded Bore Holes
With Lock Nuts
Strain Relief Fittings
Für Gewindebohrungen
Mit Gegenmuttern
Zugentlastungsverschraubungen
Thread Metal* PolyamideGewinde Metall* Polyamid
[Nm] [Nm]
M12 5.0 3.0M16 6.0 4.0M20 7.0 5.0M25 10.0 8.0M32 10.0 10.0M40 15.0 15.0M50 15.0 15.0M63 15.0 15.0
ThreadGewinde
Metal lock nut*Metall-Gegenmutter*
GMM-Mxx[Nm]
Polyamide lock nut**Polyamid-Gegenmutter**
B/GMN-Mxx[Nm]
M12 3.0 3.0M16 6.0 4.0M20 7.0 5.0M25 8.0 7.5M32 10.0 10.0M40 15.0 15.0M50 15.0 15.0M63 15.0 15.0
ThreadGewinde
MetalMetall
NVNZ-MxxxxNKNZ-Mxxxx
[Nm]EN
MetalMetall
NVNZ-Mxxxx/PNKNZ-Mxxxx/P
[Nm]
PolyamidePolyamid
S/BVNZ-Mxxxx[Nm]EN
M12 5.0 6.0 0.9M16 5.0 8.0 3.0M20 7.5 10.0 4.0M25 10.0 10.0 7.5M32 15.0 15.0 10.0M40 20.0 20.0 10.0M50 20.0 20.0 10.0M63 20.0 20.0 10.0
ThreadGewinde
PG07
MetalMetall
NVNZ-Pxxxx[Nm]6.25
MetalMetall
NVNZ-Pxxxx/P[Nm]6.0
PolyamidePolyamid
S/BVNZ-Pxxxx[Nm]
2.5PG09 6.25 8.0 3.75PG11 6.25 10.0 3.75PG13.5 6.25 10.0 3.75PG16 7.5 10.0 5.0PG21 10.0 15.0 7.5PG29 10.0 20.0 7.5PG36 10.0 30.0 7.5PG48 10.0 40.0 7.5
ThreadGewinde
Metal lock nut*Metall-Gegenmutter*
GMM-Mxx[Nm]
Polyamide lock nut**Polyamid-Gegenmutter**
B/GMN-Mxx[Nm]
PG07 2.5 2.5PG09 3.0 3.0PG11 6.3 3.8PG13.5 7.0 5.0PG16 7.0 5.0PG21 8.0 7.5PG29 10.0 10.0PG36 15.0 15.0PG48 15.0 15.0
Thread Metal* PolyamideGewinde Metall* Polyamid
[Nm] [Nm]PG07 4.0 2.0PG09 5.0 3.0PG11 6.0 4.0PG13.5 7.0 5.0PG16 10.0 8.0PG21 10.0 10.0PG29 15.0 15.0PG36 15.0 15.0PG48 15.0 15.0
* Thread combination: metal + metal / Gewindekombination: Metall + Metall ** Thread combination: metal + polyamide or polyamide + polyamide / Gewindekombination: Metall + Polyamid oder Polyamid + Polyamid
According to EN 50262Nach EN 50262
These values where gauged at standard climate (23°C/50% relative humidity) Diese Werte basieren auf Messungen bei Normklima (23°C/50% relative Luftfeuchtigkeit)
Note: The datas are approximate values. For application please take into account the influence of the counter-thread.Hinweis: Diese Angaben sind Richtwerte. Bei der Anwendung ist der Einfluss des Gegengewindes entsprechend zu berücksichtigen.
According to DIN VDE 0619 Nach DIN VDE 0619
131
Technical Annex / Technischer Anhang
Applications Engineering Information / Anwendungstechnische Hinweise
Applications EngineeringInformation
Anwendungstechnische Hinweise
Fill Factor, relevant Guidelines
The question of conduit capacity or fill factor arises in the use of cable protec-tion systems. This describes the extent to which a conduit can or should be filled with cables and/or conductors based on the available cross-sectional area.
In all cases, PMA recommends that a conduit capacity of 70% not be excee-ded. (Application-specific procedures and standards must also be considered.)This ensures that operation is not unne-cessarily impaired by increased friction between the individual conductors in dynamically moving systems. In addition, subsequent installation of additional con-ductors and/or cables is also possible if necessary.
Fill factor max. 70%Füllgrad max. 70%
fixation distances
Befestigungsdista
nz
Wiring Installation:Fixation
PMA AG recommends that cable protec-tion systems be fastened with a spacing of 300 mm to 500 mm between supports. This spacing can be varied depending on the application and location. This recom-mendation applies for all available dimen-sions. For larger diameters, the increased load due to the cables and conductors in the conduit is accounted for by adherence to the support spacing. PMA supplies sui-table system supports for various strength requirements and applications.European standard EN 50343:2003-5.15 “Railway applications – Rolling stock – Rules for installation of cabling” specifies the following spacing between supports for fastening conductors:
Horizontal wiring: 300 mmVertical wiring: 500 mm
(Application specific guidelines and stan-dards should also be considered.)
Füllgradempfehlung,relevante Vorschriften
Bei der Verwendung von Kabelschutzsys-temen stellt sich oft die Frage nach dem Füllgrad resp. Füllfaktor. Dieser beschreibt wie stark ein Wellrohr, bezogen auf den verfügbaren Querschnitt, mit Kabeln und/oder Leitern gefüllt werden kann oder soll.
PMA empfiehlt grundsätzlich den Füll-grad von 70% nicht zu überschreiten. (Anwen dungsspezifische Vorschriften und Nor men sind ergänzend zu berücksich-tigen). Dadurch wird bei dynamisch bewegten Systemen die Funktionswei-se nicht un nötig durch erhöhte Reibung zwischen den einzel nen Leitern beein-trächtigt. Zu dem wird im Bedarfsfall eine Nachin stal lation von zusätzli chen Leitern und/oder Kabeln ermöglicht.
Leitungsmontage:Befestigung
Für die Fixierung von Kabelschutzsyste men empfiehlt PMA AG eine Distanz zwischen den Montagehalterungen von 300 mm bis 500 mm. Je nach Anwendung und Lage können diese Abstände variiert werden. Diese Empfehlung gilt für alle erhältlichen Dimensionen. Bei grösseren Durchmes-sern wird der erhöhten Last durch die innenlie gen den Kabel und Lei ter, mit der Beibehal tung der Befesti gungsdistanzen Rechnung getragen. PMA bietet hierfür passende Sys tem halter für unterschied- liche Festigkeitsan for derun gen und An-wendungsbereiche an.Die Europäische Norm EN 50343:2003-5.15 “Bahnanwendungen – Bahnfahrzeuge – Regeln für die Installation von Leitungen” sieht für die Befestigung von Leitungen folgende Montagedistanzen vor:
Horizontale Verlegung: 300 mmVertikale Verlegung: 500 mm
(Anwendungsspezifische Vorschriften/Nor-men sind ergänzend zu berücksichti gen.)
132
Technical Annex / Technischer Anhang
Chemical Resistance / Chemische Beständigkeit
Chemical PA6 PA12 PP TPU PFA Formula Polyamide 6 Polyamide 12 Polypropylene
Chemische PA6.6 PA11 PE PVDFResistance against Beständigkeit gegen Formel Polyamide 6.6 Polyamide 11 Polyethylene Acetic acid (10%) Essigsäure (10%) C2H4O2 l ll lll m lllAcetone Aceton C3H6O lll lll lll m lllAmmonia (30%) Ammoniak (30%) NH3 lll lll lll m lllBenzine Benzin - lll lll ll l lllBrake fluid Bremsflüssigkeit - lll lll lll m lllCaustic soda Natronlauge HNaO lll lll lll l lllEthyl alcohol (40%) Ethanol (40%) C2H6O lll lll lll l lllGlycol Glykol C2H6O2 lll lll lll m lllHydrochloric acid (10%) Salzsäure (10%) HCL m l lll m lllMethanol Methanol CH4O ll lll lll l lllMethyl ethyl ketone Methylethylketon MEK C4H8O lll lll lll m lllNitric acid (10%) Salpetersäure (10%) HNO3 m m ll m lllOzone Ozon O3 ll ll ll l lllPaint thinner Nitroverdünner - lll lll l m lllPerchlorethylene Perchlorethylen C2Cl4 ll ll ll m lllParaffin Petroleum - lll lll l m lllPhosphoric acid (10%) Phosphorsäure (10%) H3O4P l ll lll m lllSea water Meerwasser - lll lll lll ll lllSoap solution Seifenlösung - lll lll lll ll lllSodium chloride Kochsalz NaCI lll lll lll lll lllSulphuric acid (10%) Schwefelsäure (10%) H2SO4 l ll lll m lllToluene Toluol C7H8 lll lll l m lllTrichlorethylene Trichlorethylen C2HCl3 l ll m m lllTurpentine Terpentin - lll lll m m lllUrine Urin - lll lll lll lll lll
Resistance against Beständigkeit gegenOils and Greases Öle und FetteCutting oils* Bohröle/Schneidöle* - lll lll ll l lllDiesel oil Dieselöl - lll lll ll ll lllASTM Oil Nr. 3 ASTM Oel Nr. 3 - lll lll ll l lllFuel oil Heizöl - lll lll ll l lllHydraulic oils* Hydrauliköle* - lll lll ll l lllMineral oils Mineralöle - lll lll ll lll lllSpark-erosion liquids Funkenerosionsflüssigkeiten - lll lll ll l lllSkydrol Skydrol - l ll ll m lllTransformer oils* Transformatorenöle* - lll lll ll l lll
* Synthetic additives can affect the oil resistance of plastics. Please contact PMA for further information.
lll Excellent resistance / suitable for permanent contactll Resistant / suitable for occasional contact l Relatively resistant / suitable for short-term contactm Not recommended
Important: The chemical resistance of plastic products is also dependant on factors such as temperature, amount of time exposed to chemicals (e.g. occasional contact or immersed) as well as the concentration of the specific chemicals.The stated chemical resistances are valid for a temperature of 20 °C. The chemical resistance table above serves only as a guide for the use of polyamide products in conjunction with the listed chemicals. Each specific application should be controlled for suitability by the end-user. A more detailed table can be found on the PMA Homepage under www.pma.ch.
* Synthetische Additive können die Beständigkeit von Kunststoffen gegen Öle beeinflussen. Bitte wenden Sie sich an PMA für weitergehende Informationen.lll Ausgezeichnete Beständigkeit / geeignet für Dauerkontakt ll Beständig / geeignet für gelegentlichen Kontaktl Bedingte Beständigkeit / geeignet für kurzzeitigen Kontakt
m Nicht empfohlen
Wichtig: Die chemische Beständigkeit von Kunststoff-Produkten ist ferner abhängig von der Temperatur, der Einwirk-zeit (dauerndes Ein tauchen in ein Medium oder nur gelegentlicher Kontakt) sowie von den Stoff-Konzentra-tionen. Die angegebenen Beständigkeiten gelten für eine Temperatur von 20 °C. Die aufgeführte Beständig-keitstabelle dient als Anhaltspunkt für den Einsatz von PA-Produkten in Verbindung mit den angege be nen Stoffen. Die Eignung muss jedoch in der spezifischen An wen dung durch den Benutzer über prüft werden. Eine weiterführende Tabelle finden Sie auf der PMA-Homepage unter www.pma.ch.
Chemical Resistance Chemische Beständigkeit
133
Index / Index
Products in alphabetical Order / Produkte in alphabetischer Folge
*FVD-100707GT 80*FVD-101010GT 80*FVD-121010GT 80*FVD-171010GT 80*FVD-171212GT 80*FVD-231717GT 80*GP-16G 84*GP-16T 84*GP-21G 84*GP-21T 84*GP-29G 84*GP-29T 84*GP-36G 84*GP-36T 84*GP-48G 84*GP-48T 84*GP-56G 84*VAD-G000GT 72*VAD-G012GT 72*VAD-G027GT 72*VAD-G043GT 72*VAD-G069GT 72*VAD-G076GT 72*VAD-G088GT 72*VAD-G098GT 72*VAD-M120GT 55*VAD-M160GT 55*VAD-M162GT 55*VAD-M202GT 55*VAD-M207GT 55*VAD-M253GT 55*VAD-M329GT 55*VAD-M406GT 55*VAD-M506GT 55*VAD-M508GT 55*VAD-M638GT 55*VAD-N022GT 74*VAD-N027GT 74*VAD-N043GT 74*VAD-N069GT 74*VAD-N076GT 74*VAD-N088GT 74*VAD-N098GT 74*VAD-P090GT 66*VAD-P112GT 66*VAD-P132GT 66*VAD-P137GT 66*VAD-P167GT 66*VAD-P213GT 66*VAD-P299GT 66*VAD-P366GT 66*VAD-P488GT 66*VAV-G000 72*VAV-G012 72*VAV-G027 72*VAV-G043 72*VAV-G069 72*VAV-G076 72*VAV-G098 72*VAV-M160 55*VAV-M162 55*VAV-M202 55*VAV-M207 55*VAV-M253 55*VAV-M329 55*VAV-M406 55*VAV-M506 55*VAV-M508 55*VAV-M638 55
*VAV-N022 74*VAV-N027 74*VAV-N043 74*VAV-N069 74*VAV-N076 74*VAV-N088 74*VAV-N098 74*VAV-P090 66*VAV-P112 66*VAV-P132 66*VAV-P137 66*VAV-P167 66*VAV-P213 66*VAV-P299 66*VAV-P366 66*VAV-P488 66*VBD-M207GT 56*VBD-M253GT 56*VBD-M257GT 56*VBD-M323GT 56*VBD-M329GT 56*VBD-M406GT 56*VBD-M409GT 56*VBD-M506GT 56*VBD-M508GT 56*VBD-M638GT 56*VBD-P167GT 66*VBD-P213GT 66*VBD-P299GT 66*VBD-P366GT 66*VBD-P488GT 66*VBV-M207 56*VBV-M253 56*VBV-M257 56*VBV-M323 56*VBV-M329 56*VBV-M406 56*VBV-M409 56*VBV-M506 56*VBV-M508 56*VBV-M638 56*VBV-P167 66*VBV-P213 66*VBV-P299 66*VBV-P366 66*VBV-P488 66*VH-17-000 83*VH-17-010 83*VH-17-020 83*VH-23-000 83*VH-23-010 83*VH-23-020 83*VH-29-000 83*VH-29-010 83*VH-29-020 83*VH-36-000 83*VH-36-010 83*VH-36-020 83*VH-48-000 83*VH-48-010 83*VH-48-020 83*VND-G000GT 72*VND-G00MGT 72*VND-G010GT 72*VND-G012GT 72*VND-G022GT 72*VND-G027GT 72*VND-G043GT 72*VND-G069GT 72
*VND-G076GT 72*VND-G088GT 72*VND-G098GT 72*VND-M120GT 54*VND-M12MGT 54*VND-M160GT 54*VND-M162GT 54*VND-M200GT 54*VND-M202GT 54*VND-M203GT 54*VND-M207GT 54*VND-M253GT 54*VND-M257GT 54*VND-M323GT 54*VND-M329GT 54*VND-M406GT 54*VND-M409GT 54*VND-M506GT 54*VND-M508GT 54*VND-M638GT 54*VND-N022GT 74*VND-N027GT 74*VND-N043GT 74*VND-N069GT 74*VND-N076GT 74*VND-N088GT 74*VND-N098GT 74*VND-P070GT-11 64*VND-P070GT-8 64*VND-P072GT-11 64*VND-P072GT-8 64*VND-P07MGT-11 64*VND-P07MGT-8 64*VND-P090GT-11 64*VND-P090GT-8 64*VND-P092GT-11 64*VND-P092GT-8 64*VND-P097GT-11 64*VND-P097GT-8 64*VND-P09MGT-11 64*VND-P09MGT-8 64*VND-P110GT-11 64*VND-P110GT-8 64*VND-P112GT-11 64*VND-P112GT-8 64*VND-P117GT-11 64*VND-P117GT-8 64*VND-P11MGT-11 64*VND-P11MGT-8 64*VND-P130GT-11 64*VND-P130GT-8 64*VND-P132GT-11 64*VND-P132GT-8 64*VND-P137GT-11 64*VND-P137GT-8 64*VND-P13MGT-11 64*VND-P13MGT-8 64*VND-P160GT-11 64*VND-P160GT-8 64*VND-P162GT-11 64*VND-P163GT-11 64*VND-P163GT-8 64*VND-P167GT-11 64*VND-P167GT-8 64*VND-P213GT 64*VND-P296GT 64*VND-P299GT 64*VND-P366GT 64*VND-P368GT 64
*VND-P428GT 64*VND-P488GT 64*VNDZ-M160GT 55*VNDZ-M162GT 55*VNDZ-M207GT 55*VNDZ-M253GT 55*VNDZ-M329GT 55*VNDZ-M406GT 55*VNDZ-M508GT 55*VNDZ-M638GT 55*VNDZ-P090GT 65*VNDZ-P112GT 65*VNDZ-P132GT 65*VNDZ-P137GT 65*VNDZ-P163GT 65*VNDZ-P167GT 65*VNDZ-P213GT 65*VNDZ-P299GT 65*VNDZ-P366GT 65*VNDZ-P488GT 65*VNR-RE12 98*VNR-RE12-24 98*VNR-RE1317 98*VNR-RE1317-28 98*VNR-RE17 98*VNR-RE17-28 98*VNR-RE23 98*VNR-RE23-32 98*VNR-RE29 98*VNR-RE29-44 98*VNR-RE36 98*VNR-RE36-50 98*VNR-RE48 98*VNR-RE48-65 98*VNR-REM162 98*VNR-REM162-24 98*VNR-REM187 98*VNR-REM187-28 98*VNR-REM207 98*VNR-REM207-28 98*VNR-REM253 98*VNR-REM253-32 98*VNR-REM329 98*VNR-REM329-44 98*VNR-REM406 98*VNR-REM406-50 98*VNR-REM508 98*VNR-REM508-65 98*VNV-G000 72*VNV-G00M 72*VNV-G010 72*VNV-G012 72*VNV-G022 72*VNV-G027 72*VNV-G043 72*VNV-G069 72*VNV-G076 72*VNV-G088 72*VNV-G098 72*VNV-M120 54*VNV-M12M 54*VNV-M160 54*VNV-M162 54*VNV-M200 54*VNV-M202 54*VNV-M203 54*VNV-M207 54*VNV-M253 54*VNV-M257 54
134
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
*VNV-M323 54*VNV-M329 54*VNV-M406 54*VNV-M409 54*VNV-M506 54*VNV-M508 54*VNV-M638 54*VNV-N022 74*VNV-N027 74*VNV-N043 74*VNV-N069 74*VNV-N076 74*VNV-N088 74*VNV-N098 74*VNV-P070 64*VNV-P072 64*VNV-P07M 64*VNV-P090 64*VNV-P092 64*VNV-P097 64*VNV-P09M 64*VNV-P110 64*VNV-P112 64*VNV-P117 64*VNV-P11M 64*VNV-P130 64*VNV-P132 64*VNV-P137 64*VNV-P13M 64*VNV-P162 64*VNV-P163 64*VNV-P167 64*VNV-P213 64*VNV-P296 64*VNV-P299 64*VNV-P366 64*VNV-P368 64*VNV-P428 64*VNV-P488 64*VNZ-M162S 55*VNZ-M207S 55*VNZ-M253S 55*VNZ-M329S 55*VNZ-M406S 55*VNZ-M508S 55*VNZ-M638S 55*VNZ-P090S 65*VNZ-P112S 65*VNZ-P132S 65*VNZ-P137S 65*VNZ-P163S 65*VNZ-P167S 65*VNZ-P213S 65*VNZ-P299S 65*VNZ-P366S 65*VNZ-P488S 65*VOD-P167GT 75*VOD-P213GT 75*VOD-P299GT 75*VOD-P366GT 75*VOD-P488GT 75*VOV-P167 75*VOV-P213 75*VOV-P299 75*VOV-P366 75*VOV-P488 75*VSGD-1212GT 99*VSGD-1717GT 99*VSGD-2323GT 99
*VSGD-2929GT 99*VSGD-3636GT 99*VSGD-4848GT 99*VSGR-1212 99*VSGR-1717 99*VSGR-2323 99*VSGR-2929 99*VSGR-3636 99*VSGR-4848 99*VTD-101010GT 81*VTD-121212GT 81*VTD-171717GT 81*VTD-232323GT 81*VTD-292929GT 81*VTD-363636GT 81*VTD-484848GT 81*VTR-101010 81*VTR-121212 81*VTR-171717 81*VTR-232323 81*VTR-292929 81*VTR-363636 81*VTR-484848 81*VWD-G000GT 73*VWD-G00MGT 73*VWD-G010GT 73*VWD-G012GT 73*VWD-G022GT 73*VWD-G027GT 73*VWD-G043GT 73*VWD-G069GT 73*VWD-G076GT 73*VWD-G088GT 73*VWD-G098GT 73*VWD-M120GT 56*VWD-M12MGT 56*VWD-M160GT 56*VWD-M162GT 56*VWD-M200GT 56*VWD-M202GT 56*VWD-M207GT 56*VWD-M253GT 56*VWD-M329GT 56*VWD-M406GT 56*VWD-M508GT 56*VWD-N022GT 75*VWD-N027GT 75*VWD-N043GT 75*VWD-N069GT 75*VWD-N076GT 75*VWD-N088GT 75*VWD-N098GT 75*VWD-P070GT-11 67*VWD-P070GT-8 67*VWD-P072GT-11 67*VWD-P072GT-8 67*VWD-P07MGT-11 67*VWD-P07MGT-8 67*VWD-P090GT-11 67*VWD-P090GT-8 67*VWD-P092GT-11 67*VWD-P092GT-8 67*VWD-P09MGT-11 67*VWD-P09MGT-8 67*VWD-P110GT-11 67*VWD-P110GT-8 67*VWD-P112GT-11 67*VWD-P112GT-8 67*VWD-P11MGT-11 67
*VWD-P11MGT-8 67*VWD-P130GT-11 67*VWD-P130GT-8 67*VWD-P132GT-11 67*VWD-P132GT-8 67*VWD-P137GT-11 67*VWD-P137GT-8 67*VWD-P13MGT-11 67*VWD-P13MGT-8 67*VWD-P167GT-11 67*VWD-P167GT-8 67*VWD-P213GT 67*VWD-P299GT 67*VWD-P366GT 67*VWD-P488GT 67*VWV-G000 73*VWV-G00M 73*VWV-G010 73*VWV-G012 73*VWV-G022 73*VWV-G027 73*VWV-G043 73*VWV-G069 73*VWV-G076 73*VWV-G088 73*VWV-G098 73*VWV-M120 56*VWV-M12M 56*VWV-M160 56*VWV-M162 56*VWV-M202 56*VWV-M207 56*VWV-M253 56*VWV-M329 56*VWV-M406 56*VWV-M508 56*VWV-N022 75*VWV-N027 75*VWV-N043 75*VWV-N069 75*VWV-N076 75*VWV-N088 75*VWV-N098 75*VWV-P070 67*VWV-P072 67*VWV-P07M 67*VWV-P090 67*VWV-P092 67*VWV-P09M 67*VWV-P110 67*VWV-P112 67*VWV-P11M 67*VWV-P130 67*VWV-P132 67*VWV-P137 67*VWV-P13M 67*VWV-P167 67*VWV-P213 67*VWV-P299 67*VWV-P366 67*VWV-P488 67*VYD-100707GT 80*VYD-121010GT 80*VYD-171212GT 80*VYD-231717GT 80*VYD-292323GT 80*VYD-362929GT 80*VYD-483636GT 80*VYR-100707 80
*VYR-121010 80*VYR-171212 80*VYR-231717 80*VYR-292323 80*VYR-362929 80*VYR-483636 800709M 1050907M 1050911M 1050913M 1051107M 1051109M 1051109N 1061113M 1051116M 1051121M 1051307M 1051309M 1051309N 1061311M 1051311N 1061316M 1051321M 1051607M 1051609M 1051609N 1061611M 1051611N 1061613M 1051613N 1061621M 1051629M 1052111M 1052113M 1052113N 1062116M 1052116N 1062129M 1052916M 1052921M 1052921N 1062936M 1053621M 1053629M 1053629N 1064229M 1054236M 1054248M 1054836M 1054842M 105514-07 110514-09 110514-11 110514-13 110514-16 110514-21 110514-29 110514-36 110514-48 110514-M12 110514-M16 110514-M20 110514-M25 110514-M32 110514-M40 110514-M50 110514-M63 110AFN2-07GT 101AFN2-10GT 101
135
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
AFN2-12GT 101AFN2-17GT 101AFN2-23GT 101AFN2-29GT 101AFN2-36GT 101AFN2-48GT 101ALAD-M120 115ALAD-M160 115ALAD-M162 115ALAD-M202 115ALAD-M207 115ALAD-M253 115ALAD-M257 115ALAD-M323 115ALAD-M329 115ALAD-M406 115ALAD-M409 115ALAD-M506 115ALAD-M508 115ALAD-M638 115ALAD-P090 117ALAD-P112 117ALAD-P132 117ALAD-P137 117ALAD-P167 117ALAD-P213 117ALAD-P299 117ALAD-P366 117ALAD-P488 117ALND-M120 115ALND-M160 115ALND-M162 115ALND-M200 115ALND-M202 115ALND-M207 115ALND-M253 115ALND-M257 115ALND-M323 115ALND-M329 115ALND-M406 115ALND-M409 115ALND-M506 115ALND-M508 115ALND-M638 115ALND-P070 116ALND-P090 116ALND-P092 116ALND-P110 116ALND-P112 116ALND-P132 116ALND-P137 116ALND-P167 116ALND-P213 116ALND-P299 116ALND-P366 116ALND-P488 116ALWD-M120 116ALWD-M160 116ALWD-M162 116ALWD-M202 116ALWD-M207 116ALWD-M253 116ALWD-M257 116ALWD-M323 116ALWD-M329 116ALWD-M406 116ALWD-M409 116ALWD-M506 116ALWD-M508 116
ALWD-M638 116ALWD-P070 117ALWD-P090 117ALWD-P092 117ALWD-P110 117ALWD-P112 117ALWD-P130 117ALWD-P132 117ALWD-P137 117ALWD-P167 117ALWD-P213 117ALWD-P299 117ALWD-P366 117ALWD-P488 117BAVD-10/07GT 99BAVD-12/10GT 99BAVD-17/10GT 99BAVD-17/12GT 99BAVD-23/10GT 99BAVD-23/12GT 99BAVD-23/17GT 99BAVD-29/10GT 99BAVD-29/12GT 99BAVD-29/17GT 99BAVD-29/23GT 99BAVD-36/29GT 99BAVD-48/36GT 99BAVR-10/07 99BAVR-12/10 99BAVR-17/10 99BAVR-17/12 99BAVR-23/10 99BAVR-23/12 99BAVR-23/17 99BAVR-29/10 99BAVR-29/12 99BAVR-29/17 99BAVR-29/23 99BAVR-36/29 99BAVR-48/36 99BCT-10 100BCT-12 100BCT-17 100BCT-23 100BCT-29 100BCT-36 100BFH-07-0 82BFH-10-0 82BFH-12-0 82BFH-17-0 82BFH-23-0 82BFH-29-0 82BFH-36-0 82BFH-48-0 82BFHS-00 82BFHS-PH 82BFHS-PH1 82BFIL-P070 77BFIL-P07M 77BFIL-P090 77BFIL-P112 77BFIL-P117 77BFIL-P132 77BFIL-P137 77BFIL-P160 77BFIL-P167 77BFIL-P213 77BFIL-P217 77BFIL-P293 77
BFIL-P299 77BFIL-P363 77BFIL-P366 77BFIL-P369 77BFIL-P488 77BGG-125 88BGG-56 88BGG-70 88BGG-95 88BGG-M6356 89BGG-P3656 89BGGV-56 87BGGV-70 87BGGV-95 87BGH-23 86BGH-29 86BGH-36 86BGH-48 86BGH-56 86BGH-56 91BGH-70 86BGH-70 91BGH-95 86BGH-95 91BGI-M7556 89BGL-07 86BGL-10 86BGL-12 86BGL-17 86BGL-23 86BGL-29 86BGN-S12T 85BGN-S17G 85BGN-S17T 85BGN-S23G 85BGN-S23T 85BGN-S29G 85BGN-S29T 85BGN-S36G 85BGN-S36T 85BGN-S48G 85BGN-S48T 85BGN-S70G 85BGO-56 88BGO-70 88BGO-95 88BGOV-56 87BGOV-70 87BGOV-95 87BGPS-17 84BGPS-23 84BGPS-29 84BGPS-36 84BGPS-48 84BGPS-56 84BKIHG-U212 48BKIHG-U217 48BKIHG-U242 48BKIHG-U243 48BKIHG-U247 48BKIHG-U292 48BKIHG-U293 48BKIHG-U297 48BKIHG-U299 48BKIHG-U353 48BKIHG-U357 48BKIHG-U359 48BKIHG-U433 48BKIHG-U439 48
BKIHG-U503 48BKIHG-U506 48BKIHG-U508 48BKIHG-U509 48BKIHG-U566 48BKIHG-U568 48BLN-M16 92BLN-M20 92BLN-M25 92BLN-M32 92BLN-M40 92BLN-M50 92BLNO-M160 92BLNO-M162 92BLNO-M202 92BLNO-M207 92BLNO-M253 92BLNO-M257 92BLNO-M323 92BLNO-M329 92BLNO-M406 92BLNO-M409 92BLNO-M508 92BMN-07 102BMN-09 102BMN-11 102BMN-13 102BMN-16 102BMN-21 102BMN-29 102BMN-36 102BMN-48 102BMN-M12 102BMN-M16 102BMN-M20 102BMN-M25 102BMN-M32 102BMN-M40 102BMN-M50 102BMN-M63 102BREIR-U2916 121BREIR-U3516 121BSS-17 100BSS-23 100BSS-29 100BSS-36 100BSS-48 100BSS-56G 100BSV-70G 100BVIDA-U150GT 78BVIDA-U152GT 78BVIDA-U15MGT 78BVIDA-U180GT 78BVIDA-U182GT 78BVIDA-U187GT 78BVIDA-U232GT 78BVIDA-U233GT 78BVIDA-U237GT 78BVIDA-U343GT 78BVIDA-U347GT 78BVIDA-U402GT 78BVIDA-U403GT 78BVIDA-U407GT 78BVIDB-U162GT 78BVIDB-U202GT 78BVIDB-U232GT 78BVIDB-U237GT 78BVIDB-U267GT 78BVIDB-U293GT 78
136
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
BVIDB-U297GT 78BVIDB-U323GT 78BVIDB-U353GT 78BVIDB-U357GT 78BVIDB-U359GT 78BVIDG-U212GT 79BVIDG-U217GT 79BVIDG-U242GT 79BVIDG-U247GT 79BVIDG-U293GT 79BVIDG-U297GT 79BVIDG-U353GT 79BVIDG-U357GT 79BVIDG-U359GT 79BVIDG-U433GT 79BVIDG-U436GT 79BVIDG-U439GT 79BVIDG-U506GT 79BVIDG-U509GT 79BVIDG-U566GT 79BVIDG-U569GT 79BVID-M12MGT 76BVID-M160GT 76BVID-M162GT 76BVID-M207GT 76BVID-M253GT 76BVID-M329GT 76BVID-M406GT 76BVID-M508GT 76BVID-M638GT 76BVIRA-U150 78BVIRA-U152 78BVIRA-U15M 78BVIRA-U180 78BVIRA-U182 78BVIRA-U187 78BVIRA-U232 78BVIRA-U233 78BVIRA-U237 78BVIRA-U343 78BVIRA-U347 78BVIRA-U402 78BVIRA-U403 78BVIRA-U407 78BVIRB-U162 78BVIRB-U202 78BVIRB-U232 78BVIRB-U237 78BVIRB-U267 78BVIRB-U293 78BVIRB-U297 78BVIRB-U323 78BVIRB-U353 78BVIRB-U357 78BVIRB-U359 78BVIR-M160 76BVIR-M162 76BVIR-M202 76BVIR-M207 76BVIR-M253 76BVIR-M257 76BVIR-M329 76BVIR-M406 76BVIR-M508 76BVIR-M638 76BVIR-P070 77BVIR-P090 77BVIR-P112 77BVIR-P167 77
BVIVG-U152 79BVIVG-U187 79BVIVG-U210 79BVIVG-U212 79BVIVG-U217 79BVIVG-U242 79BVIVG-U243 79BVIVG-U247 79BVIVG-U292 79BVIVG-U293 79BVIVG-U297 79BVIVG-U299 79BVIVG-U352 79BVIVG-U353 79BVIVG-U356 79BVIVG-U357 79BVIVG-U359 79BVIVG-U433 79BVIVG-U436 79BVIVG-U437 79BVIVG-U439 79BVIVG-U503 79BVIVG-U506 79BVIVG-U508 79BVIVG-U509 79BVIVG-U563 79BVIVG-U566 79BVIVG-U568 79BVIVG-U569 79BVIVG-U628 79C.66.10GR 119C.66.10SW 119C.66.12GR 119C.66.12SW 119C.66.16GR 119C.66.16SW 119C.66.20GR 119C.66.20SW 119C.66.25GR 119C.66.25SW 119C.66.30GR 119C.66.30SW 119C.66.40GR 119C.66.40SW 119C.66.45SW 119CUSG-17B 34CUSG-17S 34CUSG-23B 34CUSG-23S 34CUSG-29B 34CUSG-29S 34CUSG-36B 34CUSG-36S 34CUSG-48B 34CUSG-48S 34CYLG-125B 19CYLG-125B 90CYLG-125S 19CYLG-125S 90CYLG-23B 19CYLG-23S 19CYLG-29B 19CYLG-29S 19CYLG-36B 19CYLG-36S 19CYLG-48B 19CYLG-48S 19CYLG-56B 19CYLG-56B 90
CYLG-56S 19CYLG-56S 90CYLG-70B 19CYLG-70B 90CYLG-70S 19CYLG-70S 90CYLG-90B 90CYLG-95B 19CYLG-95S 19CYLG-95S 90CYLT-07B 19CYLT-07S 19CYLT-10B 19CYLT-10S 19CYLT-12B 19CYLT-12S 19CYLT-17B 19CYLT-17S 19CYLT-23B 19CYLT-23S 19CYLT-29B 19CYLT-29S 19CYLT-36B 19CYLT-36S 19CYLT-48B 19CYLT-48S 19DE-M120/P1 58DE-M120/P1 59DE-M120/P2 58DE-M120/P3 58DE-M160/P1 58DE-M160/P1 59DE-M160/P1 63DE-M160/P2 58DE-M160/P2 59DE-M160/P2 63DE-M160/P3 58DE-M160/P3 59DE-M160/P3 63DE-M202/P1 58DE-M202/P1 59DE-M202/P1 63DE-M202/P3 58DE-M202/P3 59DE-M202/P3 63DE-M202/P4 58DE-M202/P4 59DE-M202/P4 63DE-M207/P1 63DE-M207/P3 58DE-M207/P3 59DE-M207/P3 63DE-M207/P4 58DE-M207/P4 59DE-M207/P4 63DE-M207/P5 58DE-M207/P5 59DE-M207/P5 63DE-M253/P5 58DE-M253/P6 58DE-M257/P4 58DE-M257/P5 58DE-M257/P5 59DE-M257/P5 63DE-M257/P6 58DE-M257/P6 59DE-M257/P6 63DE-M323/P4 58DE-M323/P4 59
DE-M323/P4 63DE-M323/P5 58DE-M323/P5 59DE-M329/P2 58DE-M329/P2 59DE-M329/P3 58DE-M329/P3 59DE-M329/P4 58DE-M406/P1 58DE-M406/P2 58DE-M409/P1 58DE-M409/P2 58DE-M409/P3 58DE-M409/P3 59DE-M409/P4 58DE-M409/P4 59DE-M409/P5 58DE-M409/P5 59DE-M506/P1 58DE-M506/P1 59DE-M506/P3 58DE-M506/P3 59DE-M508/P2 58DE-M508/P2 59DE-M508/P3 58DE-M508/P3 59DE-M638/P1 58DE-M638/P1 59DE-M638/P2 58DE-M638/P2 59DE-P090/P1 69DE-P090/P3 69DE-P110/P1 69DE-P110/P1 69DE-P110/P3 69DE-P112/P1 69DE-P112/P3 69DE-P112/P4 69DE-P167/P3 69DE-P167/P4 69DE-P167/P5 69DE-P167/P6 69DE-P213/P1 69DE-P213/P4 69DE-P213/P5 69DE-P299/P3 69DE-P299/P4 69DE-P299/P5 69DE-P366/P1 69DE-P366/P2 69DE-P366/P3 69DE-P488/P1 69DE-P488/P2 69ESDG-56B 19ESDG-70B 19ESDG-95B 19ESDT-07B 19ESDT-10B 19ESDT-12B 19ESDT-17B 19ESDT-23B 19ESDT-29B 19ESDT-36B 19ESDT-48B 19EWZ-02 111EWZ-03 111F.66.03GR 118F.66.03SW 118F.66.04GR 118
137
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
F.66.04SW 118F.66.06GR 118F.66.06SW 118F.66.08GR 118F.66.08SW 118F.66.10GR 118F.66.10SW 118F.66.12GR 118F.66.12SW 118F.66.16GR 118F.66.16SW 118F.66.20GR 118F.66.20SW 118F.66.25GR 118F.66.25SW 118F.66.30GR 118F.66.30SW 118F.66.40GR 118F.66.40SW 118F.66.50GR 118F.66.50SW 118F.66.70GR 118F.66.70SW 118F.PX.04GR 119F.PX.06GR 119F.PX.08GR 119F.PX.10GR 119F.PX.12GR 119F.PX.16GR 119F.PX.20GR 119F.PX.25GR 119F.PX.30GR 119F.PX.40GR 119FP-38 111FP-52 111FVL-100707 80FVL-101010 80FVL-121010 80FVL-171010 80FVL-171212 80FVL-231717 80G.PX.05SW 120G.PX.08SW 120G.PX.10SW 120G.PX.13SW 120G.PX.16SW 120G.PX.19SW 120G.PX.25SW 120G.PX.29SW 120G.PX.32SW 120G.PX.38SW 120G.PX.50SW 120GMM-07 103GMM-09 103GMM-11 103GMM-13 103GMM-16 103GMM-21 103GMM-29 103GMM-36 103GMM-42 103GMM-48 103GMM-M12 103GMM-M16 103GMM-M20 103GMM-M25 103GMM-M32 103GMM-M40 103GMM-M50 103
GMM-M63 103GMN-07 102GMN-09 102GMN-11 102GMN-13 102GMN-16 102GMN-21 102GMN-29 102GMN-36 102GMN-48 102GMN-M12 102GMN-M16 102GMN-M20 102GMN-M25 102GMN-M32 102GMN-M40 102GMN-M50 102GMN-M63 102HSG-00 120KNH2-NW10 49KNH2-NW12 49KNH2-NW17 49KNH2-NW23 49KNH2-NW29 49KNH2-NW36 49KNH2-NW48 49L.66.04GR 119L.66.04SW 119L.66.08GR 119L.66.08SW 119L.66.10GR 119L.66.10SW 119L.66.16GR 119L.66.16SW 119L.66.20GR 119L.66.20SW 119L.66.25GR 119L.66.25SW 119L.66.30GR 119L.66.30SW 119L.66.40GR 119L.66.40SW 119L.66.50GR 119L.66.50SW 119L.PX.04GR 120L.PX.04SW 120L.PX.08GR 120L.PX.08SW 120L.PX.10GR 120L.PX.10SW 120L.PX.16GR 120L.PX.16SW 120L.PX.20GR 120L.PX.20SW 120L.PX.25GR 120L.PX.25SW 120L.PX.30GR 120L.PX.30SW 120L.PX.40GR 120L.PX.40SW 120L.PX.50GR 120L.PX.50SW 120LLPA-07* 38LLPA-10* 38LLPA-12* 38LLPA-17* 38LLPA-23* 38LLPA-29* 38LLPA-36* 38
LLPA-48* 38LLPAG-125* 38LLPAG-17* 38LLPAG-23* 38LLPAG-29* 38LLPAG-36* 38LLPAG-48* 38LLPAG-56* 38LLPAG-70* 38LLPAG-95* 38LLPF-07* 38LLPF-10* 38LLPF-12* 38LLPF-17* 38LLPF-23* 38LLPF-29* 38LLPFG-17* 38LLPFG-23* 38LLPFG-29* 38LLPFG-36* 38LLPFG-48* 38LLPO-07* 39LLPO-10* 39LLPO-12* 39LLPO-17* 39LLPO-23* 39LLPO-29* 39LLPO-36* 39LLPO-48* 39M12M16M 104M16M12M 104M16M12M/6 104M16M20M 104M20M12M 104M20M12M/6 104M20M16M 104M20M16M/6 104M20M25M 104M25M16M 104M25M16M/6 104M25M20M 104M25M20M/6 104M25M32M 104M32M20M 104M32M20M/6 104M32M25M 104M32M25M/6 104M32M40M 104M40M25M 104M40M25M/6 104M40M32M 104M40M32M/6 104M40M50M 104M50M32M 104M50M32M/6 104M50M40M 104M50M40M/6 104M50M63M 104M63M40M 104M63M40M/6 104M63M50M 104M63M50M/6 104MAVIK-M20/01 95MAVIK-M25/01 95MAVIK-M32/01 95MAVIK-M40/01 95MAVIK-M50/01 95MAVIK-M63/01 95MAVI-M20/01 95
MAVI-M25/01 95MAVI-M32/01 95MAVI-M40/01 95MAVI-M50/01 95MAVI-M63/01 95MKAH-M120-10 46MKAH-M160-10 46MKAH-M162-10 46MKAH-M202-10 46MKAH-M207-10 46MKAH-M253-11 46MKAH-M257-11 46MKAH-M323-13 46MKAH-M329-13 46MKAH-M406-13 46MKAH-M409-13 46MKAH-M506-14 46MKAH-M508-14 46MKAH-M638-14 46MKBH-M120-10 47MKBH-M160-10 47MKBH-M162-10 47MKBH-M202-10 47MKBH-M207-10 47MKBH-M253-11 47MKBH-M257-11 47MKBH-M323-13 47MKBH-M329-13 47MKBH-M406-13 47MKBH-M409-13 47MKBH-M506-14 47MKBH-M508-14 47MKBH-M638-14 47MKNH-M120-10 44MKNH-M160-10 44MKNH-M162-10 44MKNH-M202-10 44MKNH-M207-10 44MKNH-M253-11 44MKNH-M257-11 44MKNH-M323-13 44MKNH-M329-13 44MKNH-M406-13 44MKNH-M409-13 44MKNH-M506-14 44MKNH-M508-14 44MKNH-M638-14 44MREIR-U3529 121MVAV-M120-10 60MVAV-M120-5 60MVAV-M162-10 60MVAV-M162-5 60MVAV-M207-10 60MVAV-M207-6 60MVAV-M253-11 60MVAV-M253-7 60MVAV-M257-11 60MVAV-M323-13 60MVAV-M329-13 60MVAV-M329-8 60MVAV-M406-13 60MVAV-M406-8 60MVAV-M409-13 60MVAV-M506-14 60MVAV-M508-14 60MVAV-M508-9 60MVAV-M638-10 60MVAV-M638-14 60MVAV-P090 70
138
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
MVAV-P112 70MVAV-P137 70MVAV-P167 70MVAV-P213 70MVAV-P299 70MVAV-P366 70MVAV-P488 70MVBV-M207-10 61MVBV-M207-6 61MVBV-M253-11 61MVBV-M253-7 61MVBV-M257-11 61MVBV-M257-7 61MVBV-M323-13 61MVBV-M323-8 61MVBV-M329-13 61MVBV-M329-8 61MVBV-M406-13 61MVBV-M406-8 61MVBV-M409-13 61MVBV-M409-8 61MVBV-M506-14 61MVBV-M506-9 61MVBV-M508-14 61MVBV-M508-9 61MVBV-M638-10 61MVBV-M638-14 61MVBV-P167 70MVBV-P213 70MVBV-P299 70MVBV-P366 70MVBV-P488 70MVNV-M120-10 57MVNV-M120-5 57MVNV-M160-10 57MVNV-M160-5 57MVNV-M162-10 57MVNV-M162-5 57MVNV-M202-10 57MVNV-M202-6 57MVNV-M207-10 57MVNV-M207-6 57MVNV-M253-11 57MVNV-M253-7 57MVNV-M257-11 57MVNV-M257-7 57MVNV-M323-13 57MVNV-M323-8 57MVNV-M329-13 57MVNV-M329-8 57MVNV-M406-13 57MVNV-M406-8 57MVNV-M409-13 57MVNV-M409-8 57MVNV-M506-14 57MVNV-M506-9 57MVNV-M508-14 57MVNV-M508-9 57MVNV-M638-10 57MVNV-M638-14 57MVNV-P090 68MVNV-P112 68MVNV-P137 68MVNV-P167 68MVNV-P213 68MVNV-P293 68MVNV-P299 68MVNV-P366 68MVNV-P488 68
MVWV-M120-10 62MVWV-M120-5 62MVWV-M160-10 62MVWV-M160-5 62MVWV-M162-10 62MVWV-M162-5 62MVWV-M202-10 62MVWV-M202-6 62MVWV-M207-10 62MVWV-M207-6 62MVWV-M253-11 62MVWV-M253-7 62MVWV-M329-13 62MVWV-M329-8 62MVWV-M406-13 62MVWV-M406-8 62MVWV-M508-14 62MVWV-M508-9 62MVWV-M638-10 62MVWV-M638-14 62MVWV-P090 71MVWV-P112 71MVWV-P137 71MVWV-P167 71MVWV-P213 71MVWV-P299 71MVWV-P366 71MVWV-P488 71NFN3-07 107NFN3-09 107NFN3-11 107NFN3-16 107NFN3-21 107NFN3-29 107NFN3-36 107NFN3-48 107NKAH-M120-10 46NKAH-M160-10 46NKAH-M162-10 46NKAH-M202-10 46NKAH-M207-10 46NKAH-M253-11 46NKAH-M257-11 46NKAH-M323-13 46NKAH-M329-13 46NKAH-M406-13 46NKAH-M409-13 46NKAH-M506-14 46NKAH-M508-14 46NKAH-M638-14 46NKBH-M120-10 47NKBH-M160-10 47NKBH-M162-10 47NKBH-M202-10 47NKBH-M207-10 47NKBH-M253-11 47NKBH-M257-11 47NKBH-M323-13 47NKBH-M329-13 47NKBH-M406-13 47NKBH-M409-13 47NKBH-M506-14 47NKBH-M508-14 47NKBH-M638-14 47NKIS-M162 48NKIS-M207 48NKIS-M253 48NKIS-M329 48NKIS-M406 48
NKIS-M508 48NKIS-M638 48NKNH-M120-10 44NKNH-M160-10 44NKNH-M162-10 44NKNH-M202-10 44NKNH-M207-10 44NKNH-M253-11 44NKNH-M257-11 44NKNH-M323-13 44NKNH-M329-13 44NKNH-M406-13 44NKNH-M409-13 44NKNH-M506-14 44NKNH-M508-14 44NKNH-M638-14 44NKNZ-M120/P1 45NKNZ-M120/P2 45NKNZ-M120/P3 45NKNZ-M160/P1 45NKNZ-M160/P2 45NKNZ-M160/P3 45NKNZ-M202/P1 45NKNZ-M202/P3 45NKNZ-M202/P4 45NKNZ-M207/P3 45NKNZ-M207/P3-L 45NKNZ-M207/P4 45NKNZ-M207/P5 45NKNZ-M253/P5 45NKNZ-M253/P6 45NKNZ-M257/P5 45NKNZ-M257/P5-L 45NKNZ-M257/P6 45NKNZ-M257/P6-L 45NKNZ-M323/P2 45NKNZ-M323/P2-L 45NKNZ-M323/P4 45NKNZ-M323/P4-L 45NKNZ-M323/P5 45NKNZ-M329/P2 45NKNZ-M406/P2 45NKNZ-M409/P4 45NKNZ-M409/P4-L 45NKNZ-M409/P5 45NKNZ-M506/P1 45NKNZ-M506/P3 45NKNZ-M508/P2 45NKNZ-M508/P3 45NKNZ-M638/P1 45NKNZ-M638/P2 45NSBV-M207-10 94NSBV-M253-11 94NSBV-M329-13 94NSBV-M406-13 94NSBV-M409-13 94NSBV-M508-14 94NSBV-M638-14 94NSBV-P167-6.5 94NSBV-P213-7 94NSBV-P299-8 94NSBV-P366-9 94NSBV-P488-10 94NVAV-M120-10 60NVAV-M120-5 60NVAV-M162-10 60NVAV-M162-5 60NVAV-M207-10 60NVAV-M207-6 60
NVAV-M253-11 60NVAV-M253-7 60NVAV-M257-11 60NVAV-M323-13 60NVAV-M329-13 60NVAV-M329-8 60NVAV-M406-13 60NVAV-M406-8 60NVAV-M409-13 60NVAV-M506-14 60NVAV-M508-14 60NVAV-M508-9 60NVAV-M638-10 60NVAV-M638-14 60NVAV-P090 70NVAV-P112 70NVAV-P137 70NVAV-P167 70NVAV-P213 70NVAV-P299 70NVAV-P366 70NVAV-P488 70NVBV-M207-10 61NVBV-M207-6 61NVBV-M253-11 61NVBV-M253-7 61NVBV-M257-11 61NVBV-M257-7 61NVBV-M323-13 61NVBV-M323-8 61NVBV-M329-13 61NVBV-M329-8 61NVBV-M406-13 61NVBV-M406-8 61NVBV-M409-13 61NVBV-M409-8 61NVBV-M506-14 61NVBV-M506-9 61NVBV-M508-14 61NVBV-M508-9 61NVBV-M638-10 61NVBV-M638-14 61NVBV-P167 70NVBV-P213 70NVBV-P299 70NVBV-P366 70NVBV-P488 70NVIR-M120 76NVIR-M160 76NVIR-M162 76NVIR-M207 76NVIR-M253 76NVIR-M329 76NVIR-M406 76NVIR-M508 76NVIR-M638 76NVIZR-P07M 77NVIZR-P090 77NVIZR-P110 77NVIZR-P112 77NVIZR-P167 77NVIZR-P213 77NVIZR-P299 77NVIZR-P366 77NVIZR-P488 77NVN3-07 107NVN3-09 107NVN3-11 107NVN3-16 107
139
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
NVN3-21 107NVN3-29 107NVN3-36 107NVN3-48 107NVNV-M120-10 57NVNV-M120-5 57NVNV-M160-10 57NVNV-M160-5 57NVNV-M162-10 57NVNV-M162-5 57NVNV-M202-10 57NVNV-M202-6 57NVNV-M207-10 57NVNV-M207-6 57NVNV-M253-11 57NVNV-M253-7 57NVNV-M257-11 57NVNV-M257-7 57NVNV-M323-13 57NVNV-M323-8 57NVNV-M329-13 57NVNV-M329-8 57NVNV-M406-13 57NVNV-M406-8 57NVNV-M409-13 57NVNV-M409-8 57NVNV-M506-14 57NVNV-M506-9 57NVNV-M508-14 57NVNV-M508-9 57NVNV-M638-10 57NVNV-M638-14 57NVNV-P090 68NVNV-P112 68NVNV-P137 68NVNV-P167 68NVNV-P213 68NVNV-P293 68NVNV-P299 68NVNV-P366 68NVNV-P488 68NVNZ-M120R/P 58NVNZ-M120R/P-L 59NVNZ-M120S/P1 58NVNZ-M120S/P1-L 59NVNZ-M120S/P2 58NVNZ-M120S/P3 58NVNZ-M160R/P 58NVNZ-M160R/P-L 59NVNZ-M160S/P1 58NVNZ-M160S/P1-L 59NVNZ-M160S/P2 58NVNZ-M160S/P2-L 59NVNZ-M160S/P3 58NVNZ-M160S/P3-L 59NVNZ-M202R/P 58NVNZ-M202R/P-L 59NVNZ-M202S/P1 58NVNZ-M202S/P1-L 59NVNZ-M202S/P3 58NVNZ-M202S/P3-L 59NVNZ-M202S/P4 58NVNZ-M202S/P4-L 59NVNZ-M207R/P 58NVNZ-M207R/P-L 59NVNZ-M207S/P3 58NVNZ-M207S/P3-L 59NVNZ-M207S/P4 58NVNZ-M207S/P4-L 59
NVNZ-M207S/P5 58NVNZ-M207S/P5-L 59NVNZ-M253R/P 58NVNZ-M253S/P5 58NVNZ-M253S/P6 58NVNZ-M257R/P 58NVNZ-M257R/P-L 59NVNZ-M257S/P4 58NVNZ-M257S/P5 58NVNZ-M257S/P5-L 59NVNZ-M257S/P6 58NVNZ-M257S/P6-L 59NVNZ-M323R/P 58NVNZ-M323R/P-L 59NVNZ-M323R1/P 58NVNZ-M323R1/P-L 59NVNZ-M323S/P4 58NVNZ-M323S/P4-L 59NVNZ-M323S/P5 58NVNZ-M323S/P5-L 59NVNZ-M329R/P 58NVNZ-M329R/P-L 59NVNZ-M329S/P2 58NVNZ-M329S/P2-L 59NVNZ-M329S/P3 58NVNZ-M329S/P3-L 59NVNZ-M329S/P4 58NVNZ-M406R/P 58NVNZ-M406S/P1 58NVNZ-M406S/P2 58NVNZ-M409R/P 58NVNZ-M409R/P-L 59NVNZ-M409S/P1 58NVNZ-M409S/P2 58NVNZ-M409S/P3 58NVNZ-M409S/P3-L 59NVNZ-M409S/P4 58NVNZ-M409S/P4-L 59NVNZ-M409S/P5 58NVNZ-M409S/P5-L 59NVNZ-M506R/P 58NVNZ-M506R/P-L 59NVNZ-M506S/P1 58NVNZ-M506S/P1-L 59NVNZ-M506S/P3 58NVNZ-M506S/P3-L 59NVNZ-M508R/P 58NVNZ-M508R/P-L 59NVNZ-M508S/P2 58NVNZ-M508S/P2-L 59NVNZ-M508S/P3 58NVNZ-M508S/P3-L 59NVNZ-M638R/P 58NVNZ-M638R/P-L 59NVNZ-M638S/P1 58NVNZ-M638S/P1-L 59NVNZ-M638S/P2 58NVNZ-M638S/P2-L 59NVNZ-P090R/P 69NVNZ-P090R/P 69NVNZ-P090S/P1 69NVNZ-P090S/P3 69NVNZ-P110R/P 69NVNZ-P110R/P 69NVNZ-P110S/P1 69NVNZ-P110S/P3 69NVNZ-P112R/P 69NVNZ-P112R/P 69NVNZ-P112R/P 69
NVNZ-P112S/P1 69NVNZ-P112S/P3 69NVNZ-P112S/P4 69NVNZ-P160R/P1 69NVNZ-P160S/P1 69NVNZ-P167R/P 69NVNZ-P167R/P 69NVNZ-P167R/P 69NVNZ-P167R/P 69NVNZ-P167S/P3 69NVNZ-P167S/P4 69NVNZ-P167S/P5 69NVNZ-P167S/P6 69NVNZ-P213R/P 69NVNZ-P213R/P 69NVNZ-P213R1/P 69NVNZ-P213S/P1 69NVNZ-P213S/P4 69NVNZ-P213S/P5 69NVNZ-P299R/P 69NVNZ-P299R/P 69NVNZ-P299R/P 69NVNZ-P299S/P3 69NVNZ-P299S/P4 69NVNZ-P299S/P5 69NVNZ-P366R/P 69NVNZ-P366R/P 69NVNZ-P366R/P 69NVNZ-P366S/P1 69NVNZ-P366S/P2 69NVNZ-P366S/P3 69NVNZ-P488R/P 69NVNZ-P488R/P 69NVNZ-P488S/P1 69NVNZ-P488S/P2 69NVWV-M120-10 62NVWV-M120-5 62NVWV-M160-10 62NVWV-M160-5 62NVWV-M162-10 62NVWV-M162-5 62NVWV-M202-10 62NVWV-M202-6 62NVWV-M207-10 62NVWV-M207-6 62NVWV-M253-11 62NVWV-M253-7 62NVWV-M329-13 62NVWV-M329-8 62NVWV-M406-13 62NVWV-M406-8 62NVWV-M508-14 62NVWV-M508-9 62NVWV-M638-10 62NVWV-M638-14 62NVWV-P090 71NVWV-P112 71NVWV-P137 71NVWV-P167 71NVWV-P213 71NVWV-P299 71NVWV-P366 71NVWV-P488 71NVWZ-M160R/P 63NVWZ-M160S/P1 63NVWZ-M160S/P2 63NVWZ-M160S/P3 63NVWZ-M202R/P 63NVWZ-M202S/P1 63
NVWZ-M202S/P3 63NVWZ-M202S/P4 63NVWZ-M207R/P 63NVWZ-M207S/P1 63NVWZ-M207S/P3 63NVWZ-M207S/P4 63NVWZ-M207S/P5 63NVWZ-M257R/P 63NVWZ-M257S/P5 63NVWZ-M257S/P6 63NVWZ-M323S/P4 63OVN2-07 101OVN2-10 101OVN2-12 101OVN2-17 101OVN2-23 101OVN2-29 101OVN2-36 101OVN2-48 101PACOF-07B 36PACOF-07B 93PACOF-10B 36PACOF-10B 93PACOF-12B 36PACOF-12B 93PACOF-14B 36PACOF-14B 93PACOF-17B 36PACOF-17B 93PACOF-20B 36PACOF-20B 93PACOF-23B 36PACOF-23B 93PACOF-26B 36PACOF-26B 93PACOF-29B 36PACOF-29B 93PACOF-36B 36PACOF-36B 93PACOF-48B 36PACOF-48B 93PACOF-70B 36PACOF-70B 93PCLG-125B 20PCLG-125B 90PCLG-125S 20PCLG-125S 90PCLG-17B 20PCLG-17S 20PCLG-23B 20PCLG-23S 20PCLG-29B 20PCLG-29S 20PCLG-36B 20PCLG-36S 20PCLG-48B 20PCLG-48S 20PCLG-56B 20PCLG-56B 90PCLG-56S 20PCLG-56S 90PCLG-70B 20PCLG-70B 90PCLG-70S 20PCLG-70S 90PCLG-95B 20PCLG-95B 90PCLG-95S 20PCLG-95S 90
140
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
PCLT-07B 20PCLT-07S 20PCLT-10B 20PCLT-10S 20PCLT-12B 20PCLT-12S 20PCLT-17B 20PCLT-17S 20PCLT-23B 20PCLT-23S 20PCLT-29B 20PCLT-29S 20PCLT-36B 20PCLT-36S 20PCLT-48B 20PCLT-48S 20PCSG-17B 20PCSG-17S 20PCSG-23B 20PCSG-23S 20PCSG-29B 20PCSG-29S 20PCSG-36B 20PCSG-36S 20PCSG-48B 20PCSG-48S 20PCSG-56B 20PCSG-56B 90PCSG-56S 20PCSG-56S 90PCSG-70B 20PCSG-70B 90PCSG-70S 20PCSG-70S 90PCSG-95B 20PCSG-95B 90PCSG-95S 20PCSG-95S 90PCSLG-17B 21PCSLG-17S 21PCSLG-23B 21PCSLG-23S 21PCSLG-29B 21PCSLG-29S 21PCSLG-36B 21PCSLG-36S 21PCSLG-48B 21PCSLG-48S 21PCSLT-07B 21PCSLT-07S 21PCSLT-10B 21PCSLT-10S 21PCSLT-12B 21PCSLT-12S 21PCSLT-17B 21PCSLT-17S 21PCST-07B 20PCST-07S 20PCST-10B 20PCST-10S 20PCST-12B 20PCST-12S 20PCST-17B 20PCST-17S 20PELT-10S 22PELT-10SL 22PELT-12S 22PELT-12SL 22PELT-17S 22
PELT-17SL 22PELT-23S 22PELT-23SL 22PELT-29S 22PELT-29SL 22PELT-36S 22PELT-36SL 22PELT-48S 22PELT-48SL 22PHTG-17B 15PHTG-23B 15PHTG-29B 15PHTG-36B 15PHTG-48B 15PHTT-07B 15PHTT-10B 15PHTT-12B 15PHTT-17B 15PHTT-23B 15PIHG-125B 23PIHG-125B 90PIHG-125S 23PIHG-125S 90PIHG-56B 23PIHG-56B 90PIHG-56S 23PIHG-56S 90PIHG-70B 23PIHG-70B 90PIHG-70S 23PIHG-70S 90PIHG-95B 23PIHG-95B 90PIHG-95S 23PIHG-95S 90PISG-17B 23PISG-17S 23PISG-23B 23PISG-23S 23PISG-29B 23PISG-29S 23PISG-36B 23PISG-36S 23PISG-48B 23PISG-48S 23PIST-07B 23PIST-07S 23PIST-10B 23PIST-10S 23PIST-12B 23PIST-12S 23PIST-17B 23PIST-17S 23PIST-23B 23PIST-23S 23PIST-29B 23PIST-29S 23PIST-36B 23PIST-36S 23PIST-48B 23PIST-48S 23PLUG-17B 16PLUG-17S 16PLUG-23B 16PLUG-23S 16PLUG-29B 16PLUG-29S 16PLUG-36B 16PLUG-36S 16
PLUG-48B 16PLUG-48S 16PLUT-10B 16PLUT-10S 16PLUT-12B 16PLUT-12S 16PMACUT-38 111PMACUT-52 111POHG-17B 17POHG-17S 17POHG-23B 17POHG-23S 17POHG-29B 17POHG-29S 17POHG-36B 17POHG-36S 17POHG-48B 17POHG-48S 17POHT-10B 17POHT-10S 17POHT-12B 17POHT-12S 17POSG-29B 24POSG-36B 24POSG-48B 24POSG-70B 24POSG-95B 24POST-10B 24POST-12B 24POST-17B 24POST-23B 24POST-29B 24POST-36B 24POST-48B 24PPCOF-07B 37PPCOF-07B 93PPCOF-10B 37PPCOF-10B 93PPCOF-12B 37PPCOF-12B 93PPCOF-14B 37PPCOF-14B 93PPCOF-17B 37PPCOF-17B 93PPCOF-20B 37PPCOF-20B 93PPCOF-23B 37PPCOF-23B 93PPCOF-26B 37PPCOF-26B 93PPCOF-29B 37PPCOF-29B 93PPCOF-36B 37PPCOF-36B 93PPCOF-48B 37PPCOF-48B 93PPCOF-70B 37PPCOF-70B 93PSXG-17B 18PSXG-23B 18PSXG-29B 18PSXG-36B 18PSXG-48B 18PSXT-10B 18PSXT-12B 18PUEG-56B 24PUEG-56B 90PUEG-70B 24PUEG-70B 90
PUET-23B 24PUET-29B 24PUET-36B 24PUET-48B 24PUSG-17B 34PUSG-17S 34PUSG-23B 34PUSG-23S 34PUSG-29B 34PUSG-29S 34PUSG-36B 34PUSG-36S 34PUSG-48B 34PUSG-48S 34PVDT-10P 25PVDT-12P 25PVDT-17P 25PVDT-23P 25PVDT-29P 25RKS-07 100RKS-10 100RKS-12 100RKS-17 100RKS-23 100RKS-29 100RKS-36 100RKS-48 100RKS-56 100SCA-M16-10 97SCA-M20-10 97SCA-M25-11 97SCA-M32-13 97SCA-M40-13 97SCA-M50-14 97SCA-M63-14 97SCA-P09 97SCA-P11 97SCA-P16 97SCA-P21 97SCA-P29 97SCA-P36 97SCA-P48 97SFH-07-0 82SFH-10-0 82SFH-12-0 82SFH-17-0 82SFH-23-0 82SFH-29-0 82SFH-36-0 82SFH-48-0 82SFHS-00 82SFHS-PH 82SFHS-PH1 82SGB-07 85SGB-09 85SGB-11 85SGB-16 85SGB-21 85SGB-29 85SGB-36 85SGB-48 85SGG-125 88SGG-56 88SGG-70 88SGG-95 88SGG-M6356 89SGG-P3656 89SGH-23 86SGH-29 86
141
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
SGH-36 86SGH-48 86SGH-56 86SGH-56 91SGH-70 86SGH-70 91SGH-95 86SGH-95 91SGI-M7556 89SGL-07 86SGL-10 86SGL-12 86SGL-17 86SGL-23 86SGL-29 86SGO3-125 91SGO3-56 91SGO3-70 91SGO3-95 91SGO-56 88SGO-70 88SGO-95 88SGS-125 91SGS-36 91SGS-48 91SGS-56 91SGS-70 91SGS-95 91SLAD-M120 115SLAD-M160 115SLAD-M162 115SLAD-M202 115SLAD-M207 115SLAD-M253 115SLAD-M257 115SLAD-M323 115SLAD-M329 115SLAD-M406 115SLAD-M409 115SLAD-M506 115SLAD-M508 115SLAD-M638 115SLAD-P090 117SLAD-P112 117SLAD-P132 117SLAD-P137 117SLAD-P167 117SLAD-P213 117SLAD-P299 117SLAD-P366 117SLAD-P488 117SLND-M120 115SLND-M160 115SLND-M162 115SLND-M200 115SLND-M202 115SLND-M207 115SLND-M253 115SLND-M257 115SLND-M323 115SLND-M329 115SLND-M406 115SLND-M409 115SLND-M506 115SLND-M508 115SLND-M638 115SLND-P070 116SLND-P090 116SLND-P092 116
SLND-P110 116SLND-P112 116SLND-P132 116SLND-P137 116SLND-P167 116SLND-P213 116SLND-P299 116SLND-P366 116SLND-P488 116SLWD-M120 116SLWD-M160 116SLWD-M162 116SLWD-M202 116SLWD-M207 116SLWD-M253 116SLWD-M257 116SLWD-M323 116SLWD-M329 116SLWD-M406 116SLWD-M409 116SLWD-M506 116SLWD-M508 116SLWD-M638 116SLWD-P070 117SLWD-P090 117SLWD-P092 117SLWD-P110 117SLWD-P112 117SLWD-P130 117SLWD-P132 117SLWD-P137 117SLWD-P167 117SLWD-P213 117SLWD-P299 117SLWD-P366 117SLWD-P488 117SRER-06 121SRER-16 121SRER-21 121SRER-29 121SRER-50 121SREV-40 121SVN4-07 108SVN4-09 108SVN4-11 108SVN4-13 108SVN4-16 108SVN4-21 108SVN4-29 108SVN4-36 108SVN4-42 108SVN4-48 108SVN4-G00 109SVN4-G01 109SVN4-G02 109SVN4-G04 109SVN4-G06 109SVN4-G07 109SVN4-G08 109SVN4-G09 109SVN4-M12 108SVN4-M12/02 108SVN4-M16 108SVN4-M16/02 108SVN4-M20 108SVN4-M20/02 108SVN4-M25 108SVN4-M25/02 108SVN4-M32 108
SVN4-M32/02 108SVN4-M40 108SVN4-M40/02 108SVN4-M50 108SVN4-M50/02 108SVN4-M63 108SWA-M16-10 96SWA-M20-10 96SWA-M25-11 96SWA-M32-13 96SWA-M40-13 96SWA-M50-14 96SWA-M63-14 96SWA-P09 96SWA-P11 96SWA-P16 96SWA-P21 96SWA-P29 96SWA-P36 96SWA-P48 96TFIL-F08M 79TFIL-F120 79TFIL-F12M 79TFIL-F180 79TFIL-F18M 79TFIL-F300 79TFIL-F30M 79VAMG-17B 26VAMG-17S 26VAMG-23B 26VAMG-23S 26VAMG-29B 26VAMG-29S 26VAMG-36B 26VAMG-36S 26VAMG-48B 26VAMG-48S 26VAMLG-125B 27VAMLG-125S 27VAMLG-17B 27VAMLG-17S 27VAMLG-23B 27VAMLG-23S 27VAMLG-29B 27VAMLG-29S 27VAMLG-36B 27VAMLG-36S 27VAMLG-48B 27VAMLG-48S 27VAMLG-56B 27VAMLG-56S 27VAMLG-70B 27VAMLG-70S 27VAMLG-95B 27VAMLG-95S 27VAMLT-07B 27VAMLT-07S 27VAMLT-10B 27VAMLT-10S 27VAMLT-12B 27VAMLT-12S 27VAMT-07B 26VAMT-07S 26VAMT-10B 26VAMT-10S 26VAMT-12B 26VAMT-12S 26VAMT-17B 26VAMT-17S 26
VCSG-17B 28VCSG-17S 28VCSG-23B 28VCSG-23S 28VCSG-29B 28VCSG-29S 28VCSG-36B 28VCSG-36S 28VCSG-48B 28VCSG-48S 28VCSG-56B 28VCSG-56B 90VCSG-56S 28VCSG-56S 90VCSG-70B 28VCSG-70B 90VCSG-70S 28VCSG-70S 90VCSG-95B 28VCSG-95B 90VCSG-95S 28VCSG-95S 90VCST-07B 28VCST-07S 28VCST-10B 28VCST-10S 28VCST-12B 28VCST-12S 28VCST-17B 28VCST-17S 28VOHD-07B 29VOHD-07S 29VOHD-10B 29VOHD-10S 29VOHD-12B 29VOHD-12S 29VOHG-125B 29VOHG-125B 90VOHG-125S 29VOHG-125S 90VOHG-17B 29VOHG-17S 29VOHG-23B 29VOHG-23S 29VOHG-29B 29VOHG-29S 29VOHG-36B 29VOHG-36S 29VOHG-48B 29VOHG-48S 29VOHG-56B 29VOHG-56B 90VOHG-56S 29VOHG-56S 90VOHG-70B 29VOHG-70B 90VOHG-70S 29VOHG-70S 90VOHG-95B 29VOHG-95B 90VOHG-95S 29VOHG-95S 90VUSG-17B 35VUSG-17S 35VUSG-23B 35VUSG-23S 35VUSG-29B 35VUSG-29S 35VUSG-36B 35
142
Index / Index
Products in alphabetical order / Produkte in alphabetischer Folge
VUSG-36S 35VUSG-48B 35VUSG-48S 35WPS-NW10 101WPS-NW12 101WPS-NW17 101WPS-NW23 101WPS-NW29 101WPS-NW36 101WPS-NW48 101XPCLG-17BB 30XPCLG-17SB 30XPCLG-23BB 30XPCLG-23SB 30XPCLG-29BB 30XPCLG-29SB 30XPCLG-36BB 30XPCLG-36SB 30XPCLG-48BB 30XPCLG-48SB 30XPCLT-10BB 30XPCLT-10SB 30XPCLT-12BB 30XPCLT-12SB 30XPCLT-17BB 30XPCLT-17SB 30XSOLG-17BG 31XSOLG-23BG 31XSOLG-29BG 31XSOLG-36BG 31XSOLG-48BG 31XSOLLG-17BG 32XSOLLG-23BG 32XSOLLG-29BG 32XSOLLG-36BG 32XSOLLG-48BG 32XSOLLT-12BG 32XSOLT-10BG 31XSOLT-12BG 31XVCS1H-12BG 33XVCS1H-17BG 33XVCS1H-23BG 33XVCS1H-29BG 33XVCS1H-36BG 33XVCS1H-48BG 33
Contents / Inhaltsverzeichnis
Contents Inhaltsverzeichnis
About PMA
5 Company Profile 6 Who we are 8 Application Areas
Conduits
10 Conduit Guide 14 Conduits 15 PMAFLEX Pro 19 PMAFLEX 30 PMAFLEX Multilayer 34 PMA FLEXPLus 36 PMA Divisible System 38 PMA Smart Line
Connectors
PMAFIX Pro 40 Overview 42 Safety Sealing Systems Part Number Code 43 Size Codes / Installation 44 – Metric / Metal 48 – Female Thread Adapters 49 – Sealing element
PMAFLEX
PMAFIX Pro
Über PMA
5 Firmenvorstellung 6 Wer wir sind 8 Anwendungsgebiete
Wellrohre
10 Rohrübersicht 14 Wellrohre 15 PMAFLEX Pro 19 PMAFLEX 30 PMAFLEX Mehrschicht 34 PMA FLEXPLus 36 PMA Teilbares System 38 PMA Smart Line
Anschlüsse
PMAFIX Pro 40 Übersicht 42 Sicherheits- und Dichtsysteme Nummernschlüssel 43 Grössen-Codierungen / Montage 44 – Metrisch / Metall 48 – Innengewindeadapter 49 – Dichtelement
Important Information Wichtige Information
The specifications and instructions for our customers in this document reflect the product engineering level at the time of manufacturing. PMA AG accepts no liability for damages resulting from unprofessional installation or application or misuse for a purpose. This dis claimer also includes damages to third parties. It is the cus tomer‘s responsibility to check the delivered products and immediately notify PMA AG of detected faults. It is also the customer‘s res ponsibility to test the delivered product on its applicability for the intended purpose. PMA AG will accept no liability or responsibility for their products if a product or a PMA system is combined or used together with third-party products, i.e. products from other companies than PMA AG. Jurisdiction in all legal disputes concer-ning product liability have the courts of the canton of Zurich/Switzerland. Swiss law applies.
To guarantee punctual deliveries please check availability of products before orde-ring.
The text, pictures, drawings and applica-tion photos which are published in this document may not, in part, or totally, be copied or used by any third party in any form or way. Especially the downloading of text, pictures, drawings, and applica-tion photos onto Online Services is strictly forbidden, irrespective of if they are edited for this purpose or not. At all times PMA AG reserves the right to take all legal steps necessary.
For more information go to: www.pma.ch
Die in diesem Dokument für unsere Kunden enthaltenen Angaben und Instruktionen entsprechen dem neu-esten Stand unserer Technik zum Zeit-punkt der Herstellung des Produktes. Die PMA AG lehnt jede Haftung bei unsach-gemässer Montage oder Verwendung sowie Zweckentfremdung des Produktes ab. Dieser Haftungsausschluss umfasst auch allfällige Drittschäden. Es obliegt dem Kunden, die gelieferte Ware zu prüfen und allfällig festgestellte Mängel sofort der PMA AG anzuzeigen. Es obliegt ferner dem Kunden, die Ware auf ihre Eignung zwecks einer spezifischen Anwendung zu überprüfen. Die PMA AG lehnt jegliche Haftung für ihre Produkte ab, wenn ein einzelnes Produkt oder ein PMA-System mit Fremdprodukten, d.h. Produk-ten anderer Unternehmungen kombiniert bzw. verwendet wird.Gerichtsstand für Streitig keiten bezüg-lich Produkthaftung sind die Gerichte des Kantons Zürich/Schweiz. Es kommt Schweizer Recht zur Anwendung.
Um einen reibungslosen Bestellungs-ablauf zu garantieren, bitten wir Sie, die Produkteverfügbarkeit vorab zu klären.
Die in diesem Dokument publizierten Texte, Bilder, Skizzen und Anwen dungs-fotos dürfen von Dritten weder ganz noch teil weise kopiert, bearbeitet oder ander weitig ver wendet werden. Ausge schlossen ist insbesondere auch eine Einspeisung auf Online-Dienste, unab hängig da von, ob die Fotos, Skizzen oder Texte zu diesem Zweck bearbeitet werden oder nicht. PMA AG behält sich jederzeit rechtliche Schritte vor.
Ergänzende Informationen unter: www.pma.ch
PMA Main CataloguePMA Hauptkatalog
PMAFIX Pro • PMAFIX / PMAFLEX
PMA Smart Line • PMAJACKThe content of the Thomas & Betts catalogue has been carefully checked for accuracy at the time of print. However, Thomas & Betts doesn‘t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may result from any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain.
Copyright Thomas & Betts 2008. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part of this publica-tion may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Images, trade marks, brands, designs and technology are also protected by other intellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change and improve any product specifications or other mentions in the catalogue at its own discretion and at any time. These conditions of use are governed by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute.
Diese Thomas& Betts Broschüre wird ohne Gewähr im Hinblick auf die Korrektheit der darin enthaltenen Informationen, Produkt-und Leistungs-beschreibungen herausgegeben. Der Inhalt der Broschüre wurde sorgfältig überprüft. Gleichwohl haftet Thomas& Betts nicht für Verluste oder Schäden, die sich infolge von Unrichtigkeiten oder Lücken der darin enthaltenen Infor-mationen ergeben.
© Copyright 2008 Thomas& Betts. Das Urheberrecht an dieser Broschüre steht Thomas& Betts zu, soweit nicht anders angegeben. Ohne unsere vorherige schriftliche Zustimmung darf kein Teil der Broschüre in irgendeiner Form oder durch irgendwelche Mittel reproduziert, kopiert oder verbreitet werden. Abbil-dungen, Warenzeichen, Marken, Designs, und Technologie werden auch durch weitere Gesetze zum Schutz des Urheberrechts geschützt; sie dürfen ohne schriftliche Einwilligung ihrer jeweiligen Eigentümer in keiner Weise vervielfäl-tigt werden. Thomas& Betts behält sich das Recht vor, Produktspezifikationen und sonstige Angaben in dieser Broschüre jederzeit nach eigenem Ermessen zu ändern und zu verbessern. Diese Benutzungsbedingungen unterliegen dem Recht der Niederlande. Im Fall von Rechtsstreitigkeiten sind ausschließlich die Gerichte von Amsterdam zuständig.
PMA
-KA
T. 1
D/E
– V
1.1
– 01
/13
PMA has been developing, producing and selling top quality cable protection systems since 1975. Our high quality Swiss products have rapidly earned us an excellent reputation world-wide and established us as the market leader. Our range of more than 6,500 products gives customers the protection they need in railway, mechanical engineering and shipbuilding applications worldwide. PMA products are also the solution of choice in automation, building installations and other projects where power and data cables require dependable protection.
Seit 1975 entwickelt, produziert und vertreibt die PMA Kabelschutzsysteme von höchster Qualität. Mit unseren Schweizer Qualitätsprodukten haben wir uns innerhalb kurzer Zeit weltweit einen exzellenten Namen geschaffen und uns als Marktführer etabliert. Das heute über 6’500 Produkte umfassende Sortiment bewährt sich weltweit im Bahn-, Maschinen- und Schiffbau. Aber auch in der Automation, bei Gebäudeinstallationen und in vielen weiteren Bereichen, wo Energie und Datenleitungen zuverlässig geschützt sein müssen, werden bevorzugt PMA-Produkte eingesetzt.
Germany / DeutschlandPMA Deutschland GmbHRobert-Bosch-Strasse 7D-97437 Hassfurt Tel: +49 / 9521 957 71-0Fax: +49 / 9521 957 [email protected] · www.pma-de.com
Great Britain / GrossbritannienPMA UK LimitedUnit 4 Imperial Court, Magellan CloseWalworth Industrial Estate UK-Andover, Hants SP10 5NTTel: +44 / 1264 333527Fax: +44 / 1264 [email protected] · www.pma-uk.com
USA Thomas & Betts Corporation8155 T&B BoulevardUS-Memphis, TN 38125Tel: +1 / 901 252 8000Fax: +1 / 901 252 1354www.tnb.com
PMA Headquarters / PMA Hauptsitz
Switzerland / SchweizPMA AG (Headquarters)Aathalstrasse 90 · CH-8610 UsterTel: +41 / 44 905 61 11 · Fax: +41 / 44 905 61 [email protected] · www.pma.ch
PMA – We protect your cables. PMA – Wir schützen Ihre Kabel.
PMA Subsidiaries / PMA Tochterfirmen
Austria / ÖsterreichPMA GmbHPernerstorferstrasse 9A-2700 Wiener NeustadtTel: +43 / 2622 204 66 / 0Fax: +43 / 2622 203 [email protected] · www.pma-at.com
France / FrankreichPMA France S.A.R.L.18, Avenue du Québec, Néflier Villebon Silic 607F-91945 Courtabœuf CedexTel: +33 / 169 59 16 66Fax: +33 / 169 59 16 [email protected] · www.pma-fr.com
Italy / ItalienPMA Italia s.r.l.Via Marmolada 12I-20037 Paderno Dugnano (MI)Tel: +39 / 02 91084241Fax: +39 / 02 [email protected] · www.pma-it.com
Spain / SpanienThomas & Betts Spain S.L.Pol. Ind. Cardedeu SudAvda. Vallés, 22E-08440 Cardedeu (Barcelona)Tel: +34 / 938 45 45 70Fax: +34 / 938 45 47 80 [email protected] · www.pma-es.com