pneumatic road tube counters

21
Pneumatic Road Tube Counters Version 3.0 K-Hill Signal Company, Inc. Model KBA-II (Press “Esc” to exit this presentation at anytime.)

Upload: dotruc

Post on 02-Jan-2017

222 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Pneumatic Road Tube Counters

Pneumatic Road Tube Counters

Version 3.0

K-Hill Signal Company, Inc.Model KBA-II

(Press “Esc” to exit this presentation at anytime.)

Page 2: Pneumatic Road Tube Counters

K-Hill Signal Company, Inc.Model KBA-II, Time Saver

Page 3: Pneumatic Road Tube Counters

KBA-II — Key Features 8-place alpha/numeric liquid crystal display (LCD) with backlight option;

Magnet zero reset;

Magnet interval length selection;

Selectable intervals: 1hr to 12 hrs., 1 day to 99 days, and continuous;

Magnet interval data read out;

Grand total and 24 recorded intervals;

5-year lithium batteries;

Simple to operate;

Waterproof / compact case;

1/4" (6 mm) thick walled aluminum case, with lock and chain.

Page 4: Pneumatic Road Tube Counters

KBA-II — OperationThe KBA-II Timesaver, traffic counter will count in intervals of days, or hours (in increments from 1 to 12 hours). You can log up to 24 intervals and the counter automatically stops after the last interval, for later viewing. Each logged interval will hold up to 9999 counts. The KBA II, can display the current total, each logged interval, and a real time update as vehicles pass over the road tube.

Page 5: Pneumatic Road Tube Counters

KBA-II — Operation

Toggle SideMenu Side

Display

Magnet

Note, disk magnets Note, disk magnets have been replaced have been replaced

with a wand.with a wand.

Page 6: Pneumatic Road Tube Counters

KBA-II — Operation

Ver 2.1KBA-II

No? / Yes?Turn Off

10 - 20 sec.?LCD View

Off? / Timed?Backlite

Always / IntervalCount

No? / Yes?Reset

*L:xxxxLog no00

Done / Interval / AlwaysC:000000

Each swipe will sequentially display the following screens:

Swipe the “M” (menu) sidewith magnet

Page 7: Pneumatic Road Tube Counters

KBA-II — Operation

Ver 2.1KBA-II

No? / Yes?Turn Off

10 - 20 sec.?LCD View

Off? / Timed?Backlite

1 hr, 2 hr . . . 99 daysInterval

Always / IntervalCount

No? / Yes?Reset

*L:xxxxLog no00

Done / Interval / AlwaysC:000000

Each swipe will sequentially display the following screens:

Swipe the “M” (menu) sidewith magnet

Page 8: Pneumatic Road Tube Counters

KBA-II — Operation

Ver 2.1KBA-II

No? / Yes?Turn off

10 - 20 Sec.?LCD View

Off? / Timed?Backlite

Always / IntervalCount

No? / Yes?Reset

L:xxxxLog no00

Done.C:0000

Each swipe will sequentially display the following screens:

Swipe the “T” (toggle) sidewith magnet to select options (shown here in blue).

Page 9: Pneumatic Road Tube Counters

Important NoteThe counter is designed to tally one-half count for each axle on the vehicle. Example, a two axle truck towing a two axle trailer will show up as a double count.

Page 10: Pneumatic Road Tube Counters

Important Note-cont’d

The counter will automatically shut off after completing the 24 hours of counting.

Page 11: Pneumatic Road Tube Counters

KBA-II — Installation Instructions

Step 1. Clear road surface of sharp debris that may cut the rubber tube; Step 2. Secure plugged end of the road tube to the road edge;Step 3. Secure counter end of the road tube to the opposite road edge;

Step 4. Reset (or zero) the counter and make a note of the time (on the Traffic Counter Data Collection Sheet).

Recommended Tools: Hammer

Page 12: Pneumatic Road Tube Counters

KBA-II — Calibration & Initial Setup

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

Interval or DoneC:000000

As you swipe the Menu side, the following sequence of information will be displayed. . .

Hint: set this toHint: set this to 20 sec. It will allow 20 sec. It will allow more time to view more time to view the display when the display when

extracting and extracting and recording data.recording data.

Page 13: Pneumatic Road Tube Counters

KBA-II — Calibration & Initial Setup

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

Done or Interval or AlwaysC:000000

Page 14: Pneumatic Road Tube Counters

KBA-II — Calibration & Initial Setup

“Resetting the Counter”

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

DoneC:000000

This must be set to This must be set to “Yes” by swiping with “Yes” by swiping with the magnet on the “T” the magnet on the “T” side of the counter, side of the counter, after you have after you have installed the counter installed the counter at the sampling site. at the sampling site.

Page 15: Pneumatic Road Tube Counters

KBA-II — Calibration & Initial Setup

Display

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

DoneC:000000

Total Counts

“Log no00” corresponds to the first hour (or interval period) of counts, Log no01 corresponds to the second hour of counts, and so on.

Number of counts for the 1 hour interval (Log no00). This is the number you will be entering into the summary sheet

Page 16: Pneumatic Road Tube Counters

KBA-II — Recording Collected Data

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

DoneC:000000

The “Done” will be displayed when the 24 hours of counts are completed.

Display

Page 17: Pneumatic Road Tube Counters

KBA-II — Recording Collected Data

Display

Ver 2.1KBA-II

NoTurn Off

20 sec.LCD View

OffBacklite

1 hrInterval

IntervalCount:

YesReset:

*L:xxxxLog no00

DoneC:000000

To advance the display of each “Log noXX”, you must swipe the “T” (toggle) side of the counter unit.

Page 18: Pneumatic Road Tube Counters

KBA-II — Recording Collected Data

Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter w as started

Time

Log noXX

Recorded Counts

12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30

Use this column, (rounded off to closest half hour) to indicate the time you started the counter. This will determine what row (on this form) to record your counts for each Log noXX.

Suggestions for using a form to record data:

Page 19: Pneumatic Road Tube Counters

KBA-II — Recording Collected Data

Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter w as started

Time

Log noXX

Recorded Counts

12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30

Use this column to keep track of the intervalLog no00, Log no01,…Log noXX.

Use this column to record counts for each interval, *L:xxxx.

Page 20: Pneumatic Road Tube Counters

KBA-II — Product Service Information

K-Hill Signal Company, Inc.326 West Third StreetUhrichsville, OH 44683-2036Contact: Bill HallPhone: 800-730-0872 or 740-922-0421Fax: 740-922-0421Website: www.khilltrafficounters.come-mail: [email protected]

Page 21: Pneumatic Road Tube Counters

End of Demonstration

Return Home