pneumatic solenoid valves (light type) - taiyo-ltd.co.jp valves... · pneumatic solenoid valves...

37
SR2/RB Pneumatic Solenoid Valves (Light Type) SR332/SR532……VA10 SR342/SR542……VA32 SR552………………VA54 SR562………………VA64 Precautions for Use/Selection Materials/Handling Instructions …………VA2

Upload: nguyentu

Post on 13-Feb-2018

225 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR2/RB

Pneumatic Solenoid Valves (Light Type)

SR332/SR532……VA10 SR342/SR542……VA32 SR552………………VA54

SR562………………VA64

Precautions for Use/Selection Materials/Handling Instructions …………VA2

Page 2: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR2/RB

2VA

Small-size Solenoid ValveSR2/RB

3VA

Imminent hazardous situation. Unless the situation is avoided, loss of life or serious injury may occur.

Potential hazardous situation. Unless the situation is avoided, loss of life or serious injury may occur.

Potential hazardous situation. Unless the situation is avoided, slight or medium injury, or physical damages may occur.

DANGERWARNINGCAUTION

The safety precautions stated below are to be followed to use the product safely and correctly and to safeguard both you and other persons and avoid property damage. The precautions are classified into three categories, DANGER, WARNING and CAUTION, to indicate the degree of hazard, damage and imminence. Strictly observe these important safety precautions in addition to the safety requirements specified in ISO 4414*1) and JIS B 8370*2) and other standards.

WARNING

*1)ISO 4414:Pneumatic fluid power Recommendations for the application of equipment to transmission          control systems*2)JlS B 8370:General rules of pneumatic system

●The suitability of pneumatic equipment shall be judged by the person who designs the pneumatic system or determines the specifications.●The equipment shall be handled by persons with sufficient knowledge and experience.Incorrect handling of compressed air can cause hazardous situations. Any machine or device using pneumatic equipment shall be assembled, operated and maintained by persons with sufficient knowledge and experience.●Never handle any machine or device or remove the equipment without ensuring the safety. 1) Before inspecting or servicing any machine or device, make sure that the object to be

driven is provided with drop or runaway preventing means. 2) Before removing the equipment, make sure that the above safeguard has been provided,

and discharge the compressed air in the system. 3) Before restarting any machine or device, make sure that jumping-out preventing measures

have been taken.●Use the product in an environment appropriate to the specifications.If the product is used in any equipment which may considerably affect persons or properties, such as nuclear, railroad, aircraft, vehicle and medical equipment, equipment in contact with drink or food, entertainment equipment, emergency shutoff devices, safeguards for press, brake circuits and safety equipment, particularly for a purpose requiring safety or in an outdoor area, contact us.

Precautions for use for SR SeriesPrinciple of operation

WARNING

External surge

CAUTION●For the DC solenoids of SR Series, the measures against surge shown in“Electrical Specifications” are a protective circuit for avoiding damage to the external contact due to internal surge generated when the solenoid valve is turned off (Flywheel diode). If external surge may be generated, it is necessary to provide another protective circuit for the solenoid.

●The 3-position valves, such as closed center valves, are kept in the normal position (the position to which the valve is switched when a control signal is not given to the valve) by the spring. If the supplied pressure becomes lower than the working pressure during switching, the valve will be switched to the normal position by the spring force. The unexpected operation may damage the machine or cause personal injury. Always use it within the working pressure range.

Precautions for Use Precautions for Use

Page 3: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR2/RB

4VA

Small-size Solenoid ValveSR2/RB

5VA

Model (applicable cylinders)

SR332(to φ32)

SR562(to φ125)

SR552(to φ100)

SR542(to φ50)

SR342(to φ50)

SR532(to φ32)

Numberof ports

3 VA10

VA10

VA10

VA32

VA32

VA32

VA54

VA54

VA64

VA64

5

3

5

5

5

Port size and effective sectional area(mm2)

M5

4.2

4.2

3.8

Rc1/8

4.2

4.2

3.8

10.2

10.2

9.0

Rc1/4

10.2

10.2

9.0

25

22

Rc3/8

40

35

Rc1/2 Rc3/4 Rc1Series variations Page

Normally closedNormally open

ReturnDetent

Closed centerExhaust centerPressure center

Normally closedNormally open

ReturnDetent

Closed centerExhaust centerPressure center

ReturnDetent

Closed centerExhaust centerPressure center

ReturnDetent

Closed centerExhaust centerPressure center

Valve Model and Cylinder Speed

Cylinder bore

125

Valvemodel

Piping innerdiameter

2.5

4.0

2.5

4.0

4.0

4.0

4.0

6.0

4.0

6.0

6.0

8.0

6.0

6.0

8.0

8.0

6.0

8.0

9.0

8.0

9.0

8.0

9.0

8.0

9.0

9.0

8.0

9.0

8.0

9.0

Cylinder speed [average speed in mm/s]

1000

Load rate 70%

Use the above table to find the approximate cylinder speed. Note that the actual speed varies depending on the operating conditions. Ensure that the working speed does not exceed the working speed range specified for each series.

■Setting conditions Pneumatic pressure : 0.5 MPa Piping length : 1 m on each of ports A and B Driving direction : Vertically upward Applicable cylinders : φ20 and φ25 10Z-3 Series  φ32 to φ125 10A-6 Series Cylinder stroke 150 mm

loadtheoretical cylinder thrust

Load rate=        ×100(%)One touch fittings

Load

Cylinder

0.5 MPa

100 200 300 400 500 600 700 800 900

20

25

32

40

50

63

80

100

SR532

SR542

SR532

SR542

SR542

SR552

SR542

SR552

SR562

SR542

SR552

SR562

SR552

SR562

SR552

SR562

SR562

SR532

Load rate 30%Load rate 50%

Selection MaterialsProduct Lineup

Page 4: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR2/RB

6VA

Small-size Solenoid ValveSR2/RB

7VA

●Cut the tube at a right angle. (Check for scratches on the outer surface.)Slowly push the tube all the way in. After fitting the tube, lightly pull the tube to ensure that it cannot be drawn out.

●Push the release sleeve sufficiently, and draw out the tube. (If the release sleeve is pushed insufficiently, the sleeve may bite into the tube, and the tube cannot be drawn out smoothly.)When reusing the tube, cut 15 mm or more from the tube end to avoid reuse of the bitten zone.

1. When 6 or more solenoid valves aresimultaneously operated, supply and discharge of air from and to only one end of the manifold may not give the specified flow rate. Supply and discharge air from and to both ends of the manifold.

2. In the sub-plate type and mono-manifold typevalves, there is a built-in check valve between the manifold and the solenoid discharge part of the valve to prevent backflow of pilot exhaust. The check valve cannot operate normally if the pilot exhaust pressure in the sub-plate or manifold increases. Secure an exhaust line.

CAUTION

1. Attaching and detaching the P/Q socketTake the tip of the lever with fingers, and fit it onto the pin. Push the lever until the pawl at the end of the lever engages with the convexity on the connector housing, and the socket will be attached.

①When attaching or detaching the socket, do not pull the lead wires. Doing so can cause connection failure or breaking of wires.②If the pin is bent, slowly straighten the pin with a precision screwdriver, and fit the socket.

2. Lead wire colorThe standard sockets have 300-mm lead wires. The standard lead wire colors are shown below.

●Optional valves with 1000 and 3000mm lead wires are available.●The optional valves of 2-wire type have a red wire + and a black wire - . The 3-wire type valves (for tandem solenoid) have red, white and black wires like the standard valves.

One touch fittings

One touch fittings

TubeRelease sleeve

Valve

Recommended Tubes

Material Model number Bore mmOuter dia.mm

Nylon

Urethane

Working pressure range (MPa)

0 to 1

0 to 0.5

N2-4×2

N2-6×4

TE-4×2.5

TE-6×4

φ4

φ6

φ4

φ6

φ2

φ4

φ2.5

φ4

Solenoid voltage

100 V AC

200 V AC

24 V DC

12 V DC

(Tandem solenoid)

Voltage symbol

1

2

8

6

Lead wire color

Yellow

White

Red + Black -

Brown + Black -

Red(SA)White(SB)Black(COM)

One touch fittings

Manifold

P/Q socket (SR Series)

CAUTION

1. SR*32/SR*42 Series ●Highly dust-proof and moisture-proof small connectors are available.

The solenoids provided with DC protective circuit and those provided with indicating lamp and protective circuit have polarity.If wires are connected to improper poles, short-circuiting will not occur, but the solenoid valve will not function.

All DIN sockets are provided with lamps. Therefore, the terminal block ❾ has a Y-shaped terminal for lamp circuit. When wiring, take care that the Y-shaped terminal for lamp circuit is not disconnected.Do not connect naked wire with the accessory 12. The terminal screw 11 cannot be tightened completely, and the Y-shaped terminal will come off, thereby causing lamp lighting failure or short-circuiting.

LED indicator(LED)

LED indicator, red

(+)

(-)

12

Solenoid terminalarray

Cover mountingscrew

Terminal bodyTerminal cover

Screwdriver(blade width: 4 to 4.5 mm)

2.SR552/SR562 Series

[Conforming to DIN43650 FORM B]

DIN terminal (SR Series)

Polarity of solenoid

: AC/gland

「2」:DC/+ AC/ to

「1」:DC/- AC/ to

2

1

DIN terminal type valve connecting procedures

DIN terminal type valve connecting procedures

Applicable cord (reference)JIS C3306 VCTF(vinyl cabtyre round cord)

Conductor sectional area0.75mm2

(equivalent to AWG18 to 20)

No. of cores2 cores3 cores

Finished cord outer dia.φ6.6mmφ7.0mm

●Remove the DIN socket from the valve, and separate the terminal cover ❹ and the terminal body ❻ using a screwdriver.

●Fit the cable gland ❶, washer ❷ and cable gasket ❸ onto the cable (cabtyre cord), and insert the cable to the terminal cover ❹.

●Remove about 15 mm of the cabtyre cord sheath, and remove about 5 mm of the lead wire coating.If the outer lead wire with respect to the lead wire leading out direction in the terminal cover is longer by about 8 mm than the inner lead wire, the terminal cover can be easily fitted.●Do not use crimp-style terminals for the lead wires. Insert the naked wire to the lead wire hole ❽, and tighten the set screw ❼.

*For SH Series, see the SH Series section.

❶❺

1011

12

❽ ❽

❸1

2

1

「1」:Plus「2」:Minus

1. Loosen the cover mounting screw ❶, remove the DIN socket from the solenoid, and separate the terminal cover ❷ and the terminal body ❸ with a screwdriver.

2. Fit the cable gland ❹, washer ❺ and cable gasket ❻ onto the cable (cabtyre cord), and insert the cable to the terminal cover ❷.

3. Remove about 25 mm of the cabtyre cord sheath, remove about 5 mm of the lead wire coating, and fit the crimp-style terminal 10.If the outer lead wire with respect to the lead wire leading out direction in the terminal cover is longer by about 8 mm than the inner lead wire, the terminal cover can be easily fitted.

4. Remove the terminal screw 11 from the terminal body ❸, insert the terminal (in the case of a Y-shaped terminal, loosen the screw, and fit the terminal on the screw), and tighten the terminal screw 11 to 49 N・cm±15%.*PolarityThe DC solenoid has polarity.The numbers “1” and “2” shown on the terminal screw areas of the terminal body ❸ indicate the plus and minus poles, respectively.

5. To assemble, fit the terminal cover ❷ to the terminal body ❸, and tighten the cable gland ❹.Set the gasket ❽ on the solenoid side in advance, and tighten the cover mounting screw ❶ to 30 N・cm±15% to secure the DIN socket.*Applicable cord (reference)JIS C3306 VCTF(vinyl cabtyre round cord)Sheath outer dia.: 6 to 8 mm Lead wire: AWG18 to 20

CAUTION

Handling InstructionsHandling Instructions

Page 5: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR2/RB

8VA

Small-size Solenoid ValveSR2/RB

9VA

1. Push the manual override all the way in, and operate it.The single solenoid is kept in the same state as the energized state while the manual override is held down. When the override is released, the solenoid will be restored.The double solenoid is switched to the same state as the energized state of S1 (S2) by pressing the manual override on the S1 (S2) side. The solenoid is kept in the state even if the manual override is released. To restore it, operate the manual override on the S2 (S1) side.

2. On the tandem solenoid, when the manual override is pressed all the way in with a precision screwdriver and turned to A clockwise based on the 0 position, the solenoid on the SA side is set to the same state as the energized state and locked. On the SB side, turn the override counterclockwise to B. To unlock, return the override to 0. The manual override will return to the original position with the aid of the spring, and the solenoid will be unlocked. The manual override may be damaged if it is turned excessively.

PUSH

Manual override

1. Leakage currentWhen the solenoid valve is operated by a programmable controller or is provided with a CR circuit for contact protection, ensure that leakage current of output is less than 5% of holding current. Otherwise, the solenoid valve may not turn off even if power is turned off.

2. When the solenoid valve is switched, surge voltage is generated. The surge voltage caused when the valve turns off may damage the control device contact. In such a case, it is recommended to use a valve provided with a protective circuit. (The circuit protects the solenoid also from external surge.)

When ports A and B are open to the atmosphere or port P is closed, the pressure drops when the solenoid valve operates, and it may malfunction. Keep the pressure of port P within the working pressure range.

Take care that the voltage is not dropped by the influence of other electric appliances while the valve is operating.

Use the valve constantly within the working pressure range.

Use the valve constantly within the working voltage range.

Control device

Working pressure

Power supply

CAUTION

CAUTION

●The port plug is only temporarily secured on the manifold. Reposition it appropriately to the purpose of use.If it is used at the position at which it is temporarily secured, retighten it without fail.●When assembling, carefully check for dust and scratches on the solenoid valve, manifold and gasket. (Particularly check carefully the mounting seal surfaces.)

The valve will be delivered without the sub-plate mounted. When assembling the sub-plate/manifold and valve, take care not to scratch the mounting surfaces (seal surfaces), and tighten the mounting screws to the specified torque.Take utmost care not to mount the valve in a wrong direction with respect to the sub-plate/manifold.

●Do not stack the solenoid valves. If vibration is applied to them, they may collapse, thereby causing accidents. The parts may be damaged.●Do not apply vibration or impact to the solenoid valves in stock. The parts may be damaged.

①Store the valves at a height of 30 cm or more from the floor in a cool and dark space (37℃ or less) away from direct sunlight and moisture.②Do not apply vibration or impact to the solenoid valves in stock. The parts may be damaged.

Dispose of the solenoid valves as incombustibles.Remove the pipes and joints from the manifolds, and dispose of them as aluminum materials.

Tightening Torque Table

SR332

SR342

SR532

SR542

SR552

SR562

0.4士0.05

0.5土0.05

0.4士0.05

0.5土0.05

1.1士0.1

1.4士0.1

Torque (N・m)

Assembly of sub-plate/manifold and valve

Storage

Disposal

CAUTION

Series

CAUTION

Handling InstructionsHandling Instructions

Page 6: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

10VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

11VA

3-port

2-position

Normally closed

SR332-NNO

SR332-NMM

SR332-ONO

SR332-OMM

SR532-RNO

SR532-RMM

SR532-DNO

SR532-DMM

SR532-CNO

SR532-CMM

SR532-ENO

15/20 ms or less

15/15 ms or less

15/20 ms or less

15/15 ms or less

15/30 ms or less

15/20 ms or less

15 ms or less

15 ms or less

75

80(180)

80

85(180)

125 145

150(245): Tandem type120(215)

SR532-EMM

4.2mm2 3.8mm2

4.0mm2 3.6mm2

1373.0m/s2 (294.2 m/s² in axial direction) 294.2m/s2

SR532-PNO

SR532-PMM

Direct

P・A・B

R1・R2

P・A・B

R1・R2

Normally open

5-port

2-position

Return Detent

Direct screw piping type: M5×0.8

With one touch fittings: φ4 and φ6 (tube outer dia.)

Direct screw piping type: Rc1/8

3-position

Model

ItemDirect typeEasy-manifoldSub-plate typeMono-manifold

Direct typeEasy-manifoldSub-plate typeMono-manifold

Valve Specifications

Air

Unnecessary

0.15 to 0.7 MPa

1.05 MPa

+5 to +50℃ (ambient temperature and fluid temperature)

Pushing

Free

JIS K2213 Class 1 (additive-free turbine oil ISO VG32) or its equivalent

Notes 1) Values at an air pressure of 0.5 MPa. The values were obtained at the opposite positions in thecase of 2-position valves or in the valve neutral state in the case of 3-position valves.

Notes 2) The parenthesized weight includes the weight of the sub-plate.

24 V DC, 12 V DC

100 V AC, 200 V AC

2

13

2

13

(A) (A)

(P)(R) (P)(R)

42

13 5

42

13S1 5

42

S1 S2S213 5

42

S1 S213 5

42(A)(B) (A)(B) (A)(B) (A)(B) (A)(B)

S1 S213 5(P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1)

Small-size lubrication-free solenoidvalves with valve width of 15 mmand effective sectional area of4.2 mm² (2-position type)●Suitable for driving cylinders with bores of up to 32 mm●As standard devices for protection from power surge, the valves for AC are provided with varistors, and those for DC are provided with flywheel diodes.

●The valves for AC power can be used at 100 to 120 V AC or 200 to 240 V AC available.

●The valves can be wired by various methods, e.g. Q socket, P socket, DIN socket and lead wire methods, and the Q socket, P socket and DIN socket type valves are provided with indicating lamps for easy confirmation as standard devices.

●One touch fittings for 4- and 6-mm dia. valves are standardized.●Compact tandem type double solenoid valves are available (sub-plate type, Mono-manifold type/24 V DC).

JIS symbol

Port size

Directtype

Sub-platetype

Sub-plateSub-plate/tandem type

Effectivesectionalarea

Working fluid

Lubrication

Working pressure range

Working temperature range

Manual override

Installing direction

Vibration resistance/impact resistance

Recommended lubricant

Proof test pressure

Note 1)Response timeIn ON/OFF state

Note 2)Weight (g) 130(225)    

Tandem type110(205)

Modelnumber

3-position closed center

3-position exhaust center

3-position pressure center

12 V DC

Flywheel diode against surge

140(1.7W)

8

Red

Flywheel diode

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

For 12 V DC and 24 V DC For 100 V AC and 200 V AC 24 V DC (tandem solenoid)

10.8 to 13.2

(12±10%)

Brown:+Black:-

Red:+Black:-

24 V DC (tandem solenoid)

50(1.2W)

2

Red

Surge absorbing transistor

21.6 to 26.4

(24±10%)

Red(SA)Black(COM)White(SB)

100 V AC

4

100 or more

50

36

24

60

32

20

Shading type Built-in surgeabsorbing transistor

Varistor

Yellow

90 to 132

(100  %)

Yellow

24 V DC

75(1.8W)

4

21.6 to 26.4

(24±10%)

Rated voltage

Electrical Specifications

Note) The 1 and 3m lead wires (code: 1L and 3L, optional) of the P socket and Q socket type valves are in red and black.

+32-10

200 V AC

2

50

18

12

60

16

10

Green

180 to 264

(200  %)

White

+32-10

Lead wire type: 300 mm, P/Q socket type: 300 mm (standard) P/Q socket type: 300 mm (standard)

(+)

(-)

Lead wire 12 V DC: Brown24 V DC: Red

Flywheeldiode

Lead wire: Black

Short-circuit preventing diode

Solenoid

Lead wire 100 V AC: Yellow 200 V AC: White

VaristorSolenoid

Lead wire 12 V DC: Brown24 V DC: Red

Lead wire: Black

LED indicator(LED)

LED indicator, red

100 V AC: Yellow200 V AC: White

Lead wire

LED indicator(LED)

LED indicator color 100 V AC: Yellow200 V AC: Green

Diode

SOL.A (SA): Red COM: Black

SOL.B (SB): White

S2

S1

DIN□(+)2

□(-)1

Type

Frequency Hz

Starting mA (r.m.s)

Exciting mA (r.m.s)

Current value(when ratedvoltageis applied)

Working voltagerange V

Allowable circuit leakage current value

Wiring method andlead wire length

mA

Insulation resistance MΩ

Note) Lead wire color

Color of LED indicatorMeasures against surge(standard device)

Lead wire type

Ele

ctric

circ

uit

Q socket typeP socket type

DIN socket type

Page 7: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

12VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

13VA

Mono-manifold

Common exhaust type

MF332M・MF532M

20 stations

2・4・6・8・10

P: Rc1/8 R: 1/4

Name

Port size

Piping specification

Type

Model number

Max. number of stations

Standard number of stations

Exhaust type

Direct screw piping type

Manifold Specifications

P・R1・R2・R

A・B

With one touch fittings

Side piping

Rc1/8 φ4・φ6

Easy-manifold

MF332E・MF532E

20 stations

2・4・6・8・10

P, R1, R2: Rc1/8

Direct screw piping type With one touch fittings

Front piping (valve piping)

M5×0.8 (valve piping) φ4・φ6

Item

3-port

2-position

Normally closed

SR332-NNO

SR332-NMM

SR332-ONO

SR332-OMM

SR532-RNO

SR532-RMM

SR532-DNO

SR532-DMM

SR532-CNO

SR532-CMM

SR532-ENO

75

80(180)

80

85(180)

125 145

150(245): Tandem type 120(215)

SR532-EMM

SR532-PNO

SR532-PMM

Normally open 3-position closedcenter

3-position pressure center

3-position exhaustcenter

5-port

2-position type

Return Detent

3-position

Model

Valve Specifications

●The parenthesized weight includes the weight of the sub-plate.

2 4 6 8 10

Mono-manifold

Easy-manifold

Mono-manifold

Easy-manifold

MF332M-**A

MF332M-**C

MF332M-**E

MF332E-**S

MF532M-**A

MF532M-**C

MF532M-**E

MF532E-**S

Manifold Weight Unit: g

Name

●Add the valve weight to the manifold weight.

Number of stations

135

151

145

60

180

194

188

70

225

257

245

90

300

328

316

110

315

363

345

120

420

462

444

150

405

469

445

150

540

596

572

190

495

575

545

180

660

730

700

230

Model number

Direct typeEasy-manifoldSub-plate typeMono-manifoldDirect typeEasy-manifoldSub-plate typeMono-manifold

Weight g130(225)     Tandem type 110(205)

Effective sectional area 4.2 mm²

0.1

00.1

100 200 300 400

0.20.30.40.50.60.7MPa

Valve outlet pressure

Valve outlet pressure

0.6

Flow rate ℓ/min(ANR) Flow rate ℓ/min(ANR)

0.20.30.40.5

Supply pressureMPa0.7

Effective sectional area 3.8 mm²

00.1

100 200 300 400

0.20.30.40.50.60.7MPa

0.20.30.40.5

0.7

0.1

0.6

Flow Characteristic Curves

How to read the chartWhen the flow rate is 210 ℓ/min (ANR) at a supply pressure of 0.5 MPa, the valve outletpressure is 0.4 MPa.

Supply pressureMPa

Page 8: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

14VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

15VA

■How to order valve only (3-port)●Model number of valve onlyDirect type (port size M5)Easy manifold

SR332- N NO 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plate

Sub-plate type (port size Rc1/8)Mono-manifold

SR332- N MM 1 RK - 1L - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red andblack.

Wiring methodWiring methodVoltage Symbol

Lead wire typeWith protectivecircuit

RK

Voltage (standard)

Voltage (option)

Symbol

AC100V  %(Lead wire color: yellow)

1NO

Q socket typeWith indicatinglamp/protectivecircuit

P socket typeWith indicatinglamp/protectivecircuit

DIN socket typeWith indicatinglamp/protectivecircuit

QW

PW

DW

Switching methodSwitching methodSymbol

Normally closed

N

Normally open

O

+32-10

AC200V  %(Lead wire color: white)

2+32-10

DC24V±10%(Lead wire color:+red, -black)

8

6

Other voltages9

Port sizePort size (standard)

Port size (option)

Symbol

Direct screw piping typeM5×0.8

MMFor sub-plate/Mono-manifold

VAOD of tube with jointon secondary side φ4

VBOD of tube with jointon secondary side φ6

WAOD of tube with jointson both sides φ4

WBOD of tube with jointson both sides φ6

Note) Valves with one touch fittings do not havethe two 3.2-mm dia. side mounting holes.

2

13

2

(A)

(A)

13

(P)(R)

(P)(R)

Note) The valve will be delivered without the sub-plate mounted.

◯ ◯

DC12V±10%(Lead wire color:+brown, -black)◯ ◯

How to order manifold●Model number of Mono-manifold

MF332M- 04 ASeries

How to order valve for manifold●Mono-manifold

●Mono-manifold

SR332- N MM 1 QW - 1L

■How to order seal plate SZZ

MF332-MS(for Mono-manifold)MF332-ES(for Easy-manifold)

■How to order gasket and bolt set SZZ

MF332-MGBS(for Mono-manifold)MF332-EGBS(for Easy-manifold)

Series For Mono-manifold

No. of manifold stationsNo. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Piping methodPiping methodSymbol

Side piping (direct screw piping type)

Side piping (with one touch fittings: φ4)

Side piping (with one touch fittings: φ6)

A

C

E

●Model number of Easy-manifold

MF332E- 04 SSeries

No. of manifold stationsNo. of stationsSymbol

02

04

06

08

10

Note) For details, see “How to order valve only.”

●Easy-manifold

●Easy-manifold

SR332- N NO 1 QW - 1LSeries

Port sizeNO:Direct screw piping type(M5)VA:With one touch fittings(φ4)VB:With one touch fittings(φ6)Note) For details, see “How to order valve only.”

How to order manifold

 ●A 4-station Mono-manifold type is shown as follows.  ●Manifold body   MF332M-04A  ●Valve block   SR332-NMM1RK   SR332-OMM1RK

Qty.1

22

●A 4-station Easy-manifold type is shown as follows. ●Manifold body  MF332E-04S ●Valve block  SR332-NNO1RK  SR332-ONO1RK

Qty.1

22

SR332-NMM1RK

SR332-OMM1RK

PR

3(R)1(P)2(A)

SR332-NNO1RKSR332-ONO1RK

3(R)1(P)

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

2 stations

4 stations

6 stations

8 stations

10 stations

Page 9: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

16VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

17VA

■How to order valve only (5-port)●Model number of valve onlyDirect type (port size M5)Easy manifold

SR532- R NO 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plateNote) Only return type

SR532- R MM 1 RK - 1L - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Wiring methodWiring methodSymbol

RK

Voltage (standard)Symbol

1NO

QW

PW

DW

Switching method Switching methodSymbol

Return

R

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

2

8

6

9

Port size (standard)Symbol

MM

VA

VB

WA

WB

Note) Valves with joints on both sides (WA and WB)come only in the return type.Valves with one touch fittings do not have the two3.2-mm dia. side mounting holes.

42

13 5

(A)(B)

(P)(R2)(R1)

42

13S1 5

(A)(B)

(P)(R2)(R1)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)

42(A)(B)

S1 S213 5(P)(R2)(R1)

S2

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red andblack.

Sub-plate type (port size Rc1/8)Mono-manifold

Note) The valve will be delivered without the sub-plate mounted.

Lead wire typeWith protectivecircuit

Q socket typeWith indicatinglamp/protectivecircuit

P socket typeWith indicatinglamp/protectivecircuit

DIN socket typeWith indicatinglamp/protectivecircuit

Port size

Port size (option)

Direct screw piping typeM5×0.8

For sub-plate/Mono-manifold

OD of tube with jointon secondary side φ4

OD of tube with jointon secondary side φ6

OD of tube with jointson both sides φ4

OD of tube with jointson both sides φ6

Voltage

Voltage (option)

AC100V  %(Lead wire color: yellow)

+32-10

AC200V  %(Lead wire color: white)

+32-10

DC24V±10%(Lead wire color:+red, -black)

Other voltages

◯ ◯

DC12V±10%(Lead wire color:+brown, -black)◯ ◯

■How to order valve only (5-port)●Model number of valve onlyTandem solenoid (port size Rc1/8)Mono-manifold

SR532- D DM 8 QW - 1D - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Tandem type

Lead wire lengthNo symbol: Standard (300 mm)1D: 1000 mm (order made)3D: 3000 mm (order made)Note) The lead wires are in

red, white and black.

Wiring methodWiring methodVoltage Symbol

VoltageSymbol

Q socket typeWith indicatinglamp/protectivecircuit

P socket typeWith indicatinglamp/protectivecircuit

QW

PW

Switching methodSwitching methodSymbol

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

DC24V±10%(Lead wire color: SA: red,SB: white, COM: black)

8

Note) The valve will be delivered without the sub-plate mounted.

42

13S1 5

(A)(B)

(P)(R2)(R1) S2(SB) (SA)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)(SB) (SA)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)(SB) (SA)

42(A)(B)

S1 S2(SB) (SA)

13 5(P)(R2)(R1)

Page 10: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

18VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

19VA

How to order manifold●Model number of Mono-manifold

MF532M- 04 ASeries

How to order valve for Mono-manifold●Single/double solenoid

How to order Mono-manifold  (5-port)

●A 4-station Mono-manifold is shown as follows. ●Manifold body  MF532M-04A ●Valve block  SR532-CMM1RK  SR532-DMM1RK  SR532-RMM1RK

Qty.1

112

●A 4-station Mono-manifold is shown as follows. ●Manifold body  MF532M-04C ●Valve block  SR532-CMM1RK  SR532-DMM1RK  SR532-RMM1RK

Qty.1

112

SR532- R MM 1 QW - 1L

■How to order seal plate SZZ

MF532-MS

■How to order gasket and bolt set SZZ

MF532-MGBS

Series For Mono-manifold

No. of manifold stationsNo. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Piping methodPiping methodSymbol

Side piping (direct screw piping type)

Side piping (with one touch fittings: φ4)

Side piping (with one touch fittings: φ6)

A

C

E

●Tandem solenoid

SR532- D DM 8 QW - 1DSeries Tandem type

Note) For details, see“How to order valve only.”

SR532-CMM1RK

SR532-DMM1RK

SR532-RMM1RK

PR1

3(R)

PR13(R)

PR2

Side piping(direct screw piping type)

1(P)

SR532-CMM1RK

SR532-DMM1RK

SR532-RMM1RK

1(P)PR2

Side piping(with one touch fittings: φ4)

How to order manifold●Model number of Easy-manifold

MF532E- 04 SSeries

How to order valve for Easy-manifold

No. of manifold stationsNo. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Model numberTube OD

M4-01M

M6-01M

F8-01MS

φ4

φ6

φ8

Model number

For M5 For Rc1/8

Tube OD

M4-M5M

M6-M5M

φ4

φ6

●Single/double solenoid

●One touch fittings

SR532- R NO 1 QW - 1LSeries

Note) The above three port sizes are available.

Note) For details, see“How to order valve only.”

■How to order seal plate SZZ

MF532-ES

■How to order gasket and bolt set SZZ

MF532-EGBS

■Related products: Joints and silencers More compact piping is enabled.

How to order Easy-manifold  (5-port)

●A 4-station Easy-manifold is shown as follows. ●Manifold body  MF532E-04S ●Valve block  SR532-CNO1RK  SR532-DNO1RK  SR532-RNO1RK

Qty.1

112

SR532-CNO1RK

SR532-DNO1RK

SR532-RNO1RK

5(R1)

1(P)

3(R2)

Note) The valve will be delivered without the manifold mounted.

Model numberModel number

For M5 For Rc1/8

SA2-M5 SA2-06(G1/8)

●Silencer

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

Port sizeNO:Direct screw piping type(M5)VA:With one touch fittings(φ4)VB:With one touch fittings(φ6)

Page 11: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

20VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

21VA

Unit: mm

(A)23(R)1(P) (A)2

3(R)1(P)

PR

Solenoid cover

Plunger

Manual override

Piston

Main body

End cover

Plunger pin

Plunger spring

Mold solenoid

Column

Main shaft

Lip seal

Flapper

Pilot valve body

Shading coil(only AC solenoid)

(A)23(R)

1(P)

PR

(A)23(R)

1(P)

(A)4(B)2

5(R1)

3(R2)1(P)

S2

S1

(A)4(B)2

5(R1)

3(R2)1(P)

PR

(A)4

(B)2

5(R1)

3(R2)

1(P)

PR1

PR2

S1

S2

(A)4

(B)2

5(R1)

3(R2)

1(P)

PR1

PR2

S1

S2

(A)4

(B)2

5(R1)

3(R2)

1(P)

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

Valve

Manifold

Main body

Main shaft

Lip seal

Flapper

Mounting base

Sub-base

Plunger

Column

Main body

Block plate

Seal

Electromagneticstainless steel

Name Material

Aluminum alloy(alumite)

Synthetic rubber(NBR)

Synthetic rubber(NBR)

Mild steel(galvanized)

Mild steel (nickel-plated)

Aluminum alloy (alumite)

Aluminum alloy (alumite)

Materials of Major Parts

Sectional Drawings■3-port

■5-port 2-position ■5-port 3-position

Return

SR532-DNOSR532-RNOIn non-energized state

Detent Closed center

SR532-CNO

Normally closed(NC) Normally open(NO)

SR332-NNO(Normally closed)

In non-energized state

SR332-ONO(Normally open)

In non-energized state

■Sub-plate type●SR332ーNMM Voltage RKーSP(normally closed)●SR332ーOMM Voltage RKーSP(normally open)

■Direct type●SR332ーNNO Voltage RK(normally closed)●SR332ーONO Voltage RK(normally open)

3-port/normally closed and normally open

Note) The valve will be delivered without the sub-plate mounted.

SR532-ENO

Exhaust center

SR532-PNO

Pressure center

15

Manual overrideNon-lock type

12.512

74.7

46.5

3-M5×0.82-φ2.8 spot facingφ5.4 depth 3 (Mounting holes)

2-φ3.2(Mounting holes)

PR

2-M2.6×0.45 depth 3Mounting screw holes

A

〈View A〉

20.5

3

5.55.5

99

4.5 4.5

3

18

11.514

15.5 25.5

Approx. 300 24

①②②

PR

10 20

3-Rc1/8102638

M5×0.8

46.5

74.7

15

3

3

24 30

18 10

32.2420.5

1025

2450

約300

20

③①

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

PR1

PR2

S1

S2

(A)4

(B)2

5(R1)

3(R2)

1(P)

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

PR1

PR2

S1

S2

(A)4

(B)2

5(R1)

3(R2)

1(P)

2-φ3.2(Mounting holes)

Manual overrideNon-lock type

CAD/DATAis available.SR332/TSR332A(B)

Page 12: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

22VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

23VA

Unit: mm Unit: mm

16.5

10

24Approx. 300

5

20

11.521.5

33

9

9 4.5 4.5

10

16.518

12.5

80.7

15

Manual overrideNon-lock type

5-M5×0.8

PR

32-φ2.8Spot facing φ5.4 depth 3(Mounting holes)

3

5.5 5.5

2-M2.6×0.45 depth 3Mounting screw holes

2-φ3.2(Mounting holes)

A

〈View A〉

⑤①④

PR1

PR2

2525

2020

2-φ3.2(Mounting holes)

27.530

2-M5×0.8

5-Rc1/8

12.5

46

4.5

5558.586.7

2134

7.5

17.515243 3

Manual overrideNon-lock type

30

11

17.5

202524

50Approx. 300

Approx. 300

Approx. 300

⑤④

5

5 5

5

10

10

9

9

31

59.2

118.4

15

S2

S1

33

5.5 5.5

24Approx. 300

2PR

5

2-manual overridesNon-lock type

2-manual overridesNon-lock type

5-M5×0.8

2-φ2.8Spot facing φ5.4 depth 3(Mounting holes)

④② PR1

PR2

25

20

31.72-φ3.2(Mounting holes)

27.530

12.5

46

4.5

5562

28.2

118.4

2134

7.5

17.515

243 3

Manual overrideNon-lock type

30

11

17.5

202524

50

2-M5×0.85-Rc1/8

S2S2

S1S1

⑤④

24Approx. 300

2-φ2.8Spot facing φ5.4 depth 3(Mounting holes)

5

5 5

5

10

10

9

941

33

69.2

61.2

130.4

15

S2

S1

33

5.5 5.5

2PR

5

5-M5×0.8

④②

PR1

PR2

25

20

41.7

2-φ3.2(Mounting holes)

27.530

12.5

46

4.5

55

33.7

74

28.2

130.421

34

7.5

17.515

243 3Manual overrideNon-lock type

30

11

17.5

202524

50

2-M5×0.85-Rc1/8

⑤④

■Direct type●SR532ーRNO Voltage RK(return)

■Sub-plate type●SR532ーRMM Voltage RKーSP(return)

●SR532ーDNO Voltage RK(detent) ●SR532ーDMM Voltage RKーSP(detent)

●SR532ーCNO Voltage RK(closed center)●SR532ーENO Voltage RK(exhaust center)●SR532ーPNO Voltage RK(pressure center)

●SR532ーCMM Voltage RKーSP(closed center)●SR532ーEMM Voltage RKーSP(exhaust center)●SR532ーPMM Voltage RKーSP(pressure center)

5-port/2-poition and 3-position

Note) The valve will be delivered without the sub-plate mounted.

⑤①③

⑤①③ ①

2-φ3.2(Mounting holes)

2-φ3.2(Mounting holes)

54(2.4) Pg7

(27) (34.5) (44.1)

7.5

C

13

φ14.8

1.6

24

5

79.7 (to valve upper surface)

14 14

2-φ4.5(Mounting holes)

40

1.6

24

5

85.7 (to valve upper surface)

14 14

2-φ4.5(Mounting holes)

40

1.8

20.5

8.8 for φ49.5 for φ6

8.8 for φ49.5 for φ6

M5×0.8

PR

One touch fitting

③①

②②

1.81.8

10

16.5

8.8 for φ49.5 for φ6

8.8 for φ49.5 for φ6

M5×0.8

PR

One touch fitting

⑤①

④②

36A

1034

LED indicator

29B

20.544.5

LED indicator

SR332-*N0**

SR532-RN0**

SR532-RMM**-SP

SR532-DN0**, SR532-DMM**-SP

SR532-(C, E, P)N0**, SR532-(C, E, P)*M**-SP

82.5

88.5

94.5

134

146

Standard type:300

Order made:

 1L:1000 3L:3000

 1D:1000 3D:3000

(For tandem solenoid)

Overall length to valve

or sub-base end face

Overall length to solenoid

end face on opposite side

75.5

81.5

87.5

120

132

90.6

96.6

102.6

150.2

162.2

Model numberSymbol A

Dimensional TableB C ℓ (lead wire length) Remarks

■Mounting plate SZZ SR532-F●3-port valve mounting dimensions

Option

●5-port valve mounting dimensions (only return type)

Note) The valve will be delivered without the mounting plate mounted.

■With one touch fittings●3-port valve dimensions ●5-port valve dimensions

■Wiring method●Q socket type ●P socket type ●DIN socket type

Note: PR is on the port side ②.The valve with a one touch fittings does not have the two 3.2-mm dia. side mounting holes.

Note: PR is on the port side ②④.The valve with a one touch fittings does not have the two 3.2-mm dia. side mounting holes.The valve with joints on both sides (ports ①②④)comes only in the return type.

CAD/DATAis available.SR532/TSR532A(B)

CAD/DATAis available.SR532/TSR532A(B)

Page 13: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

24VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

25VA

Unit: mm Unit: mm

A

A B

B

DC24V

30 4625

20

5556.5

84.592.798.7

152-LED indicators2430

Approx. 300

68

42 25

20

17.52-M5×0.8

3-RC1/811

13

7.5

17.537.5

Manual override2-φ2.8 (Mounting holes)φ5.4 deep spot facing depth 3

2-LED indicatorsManual override2-φ2.8 (Mounting holes)φ5.4 deep spot facing depth 3

2-φ3.2(Mounting holes)

2-RC1/8

PR1

PR2 ③

⑤①

A

A BC

A B

B

DC24V

30 46

PR1

PR2

25

20

5556.5

84.590.5

152430 Approx. 300 78.8

52.8 25

2017.5 2-M5×0.8

3-RC1/811

13

7.5

17.5

2-φ3.2(Mounting holes)

2-RC1/8

⑤①

5-port/tandem solenoid (2-position)●SR532-DDM Voltage QW-SP(detent)

●SR532-DDM Voltage PW-SP(detent)

Note) The valve will be delivered without the sub-plate mounted.

A

A B

B

DC24V

25

20

55

3.5

6694

102.2

152430

Approx.300

Approx.300

6842 25

2-M5×0.8

3-RC1/811

13

37.5

2-φ3.2(Mounting holes)

7.5

17.5

2-RC1/8

2-LED indicatorsManual override2-φ2.8 (Mounting holes)φ5.4 deep spot facing depth 3

2-LED indicatorsManual override2-φ2.8 (Mounting holes)φ5.4 deep spot facing depth 3

30 46

20

17.5

11

PR1

PR2

③①

A

A BC

A B

B

DC24V

30 4625

20

55

3.5

66

94

152430 78.8

52.8 25

2017.5 2-M5×0.8

3-RC1/811

13

2-φ3.2(Mounting holes)

PR1

PR2

7.5

17.5

2-RC1/8

⑤①

5-port/tandem solenoid (3-position)●SR532-CDM Voltage QW-SP(closed center)●SR532-EDM Voltage QW-SP(exhaust center)●SR532-PDM Voltage QW-SP(pressure center)

●SR532-CDM Voltage PW-SP(closed center)●SR532-EDM Voltage PW-SP(exhaust center)●SR532-PDM Voltage PW-SP(pressure center)

Note) The valve will be delivered without the sub-plate mounted.

Page 14: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

26VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

27VA

Unit: mm Unit: mm

158.5 15 8.5

1616 1616

P 3.53.5

L

74.7

Manual overrideNon-lock type

39

SR332-*MM*RK

16

5.2

42

SR332-*MM*RK

Seal plateMF332-MS

PR

Rc1/8

stn.1 stn.2

4-φ4.2(Mounting holes)

53

24 28

22.5

16

8

Approx. 300

13.529 36.5

2×1-M5×0.8(With 1 plug: temporarily tightened)2×2-Rc1/8(With 2 plugs: temporarily tightened)

2×1-M5×0.8(With 1 plug: temporarily tightened)2×2-Rc1/8(With 2 plugs: temporarily tightened)

8

19 16

② ②②

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

PR

158.5 15 8.5

1616 1616

P 3.53.5

L

74.7

39

SR332-*MM*RK

16

5.2

42

SR332-*MM*RK

Seal plateMF332-MS

One touch fitting

stn.1 stn.2

53

24 28

22.5

16

8

Approx. 300

13.529 36.5

8

19 16

6.8 for φ47.5 for φ6

② ② ②

Mono-manifold/MF332M (3-port)■Direct screw piping type

■With one touch fittings

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

Manual overrideNon-lock type

4-φ4.2(Mounting holes)

158.5 15 8.5

1616 1616

P 3.53.5

L

21

SR332-*NO*RK

1530

SR332-*NO*RK

Seal plateMF332-ES

stn.1 stn.2

2-φ4.2(Mounting holes)

43

24 18

11

8

4

Approx. 300

147

6

23

2×2-Rc1/8(With 2 plugs: temporarily tightened)

8.520.5

74.7

3

M5×0.8

Manual overrideNon-lock type

② ②

8.8 for φ49.5 for φ6 43

One touch fitting

20.5

1.8

③②

P

L

2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

Easy-manifold/MF332E (3-port)■Direct screw piping type

With one touch fitttings

Note: PR is on the port side ②.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

SymbolNo. of stations

CAD/DATAis available.SR332/TSR332K

CAD/DATAis available.SR332/TSR332K

Page 15: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

28VA

Small-size Solenoid Valve SR332/SR532SR2/RB SR332/SR532

29VA

Unit: mm Unit: mm

LP 3.5

1616 1615

S2 S2

S1S1

69.2

61.2

1315

29.535

60

24Approx. 300

335350

32.541

16158.5

3.5

31

59.2

21.5

Manual overrideNon-lock type

4-φ4.2(Mounting holes)

24.542

PR1

PR238

7.5

2×2-M5×0.8(With 2 plugs: temporarily tightened)2×1-Rc1/4(With 1 plug: temporarily tightened)2×1-Rc1/8(With 1 plug: temporarily tightened)

SR532-DMM*RKSR532-CMM*RK

SR532-RMM*RKSR532-RMM*RK

2-Rc1/8(for 1 station) Seal plate

MF532-MS

stn.1 stn.2 stn.3 stn.4 stn.55 3

7.5

19.5

④④

②②

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

LP 3.5

1616 16

S2 S2

S1S1

69.2

61.2

1315

29.535

60

24Approx. 300

335350

32.541

6.8 for φJ47.5 for φJ6

1615158.5

3.5

31

59.2

21.5

4-φ4.2(Mounting holes)

24.542

PR1

PR2

2×2-M5×0.8(With 2 plug: temporarily tightened)2×1-Rc1/4(With 1 plug: temporarily tightened)2×1-Rc1/8(With 1 plug: temporarily tightened)

SR532-DMM*RKSR532-CMM*RK

SR532-RMM*RKSR532-RMM*RK

2-one touch fittings (for 1 station)(for 1 station) Seal plate

MF532-MS

stn.1 stn.2 stn.3 stn.4 stn.55 3

6.5

20.5

38

7.5

②②

Mono-manifold/MF532M (5-port)■Direct screw piping type

■With one touch fittings

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

④ ④

④ ④

Manual overrideNon-lock type

A

A

ADC24V

C B

B

B

A

A

ADC24V

C B

B

B

SR532-DDM*PW

SR532-CDM*PWSR532-RMM*RK

SR532-RMM*RK

2-Rc1/8(for 1 station) Seal plateMF532-MS

stn.1 stn.2 stn.3 stn.4 stn.55 3

7.5

19.5

1315

29.535

88.8

52.8Approx. 300

6234.5

5350

32.5 15.532 24.5

42

PR1

PR238

7.5

2×2-M5×0.8(With 2 plugs: temporarily tightened)2×1-Rc1/4(With 1 plug: temporarily tightened)2×1-Rc1/8(With 1 plug: temporarily tightened)

3159.2

Manual override

21.5

2-φ4.2(Mounting holes)

LP 3.5

1616 16 1615158.5

3.5

②②

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

P

L

SymbolNo. of stations 2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

A

A

ADC24V

C B

B

B

A

A

ADC24V

C B

B

B

SR532-DDM*PW

SR532-CDM*PWSR532-RMM*RK

SR532-RMM*RK

Seal plateMF532-MS

stn.1 stn.2 stn.3 stn.4 stn.55 3

6.5

20.5

1315

29.535

88.8

52.8Approx. 300

6234.5

5350

32.5 15.532 24.5

42

PR2

PR138

7.5

2×2-M5×0.8(With 2 plugs: temporarily tightened)2×1-Rc1/4(With 1 plug: temporarily tightened)2×1-Rc1/8(With 1 plug: temporarily tightened)

3159.2

Manual override

21.5

2-φ4.2(Mounting holes)

LP 3.5

1616 16 1615158.5

3.5

7 for φJ47.5 for φJ6

2-one touch fittings(for 1 station)

②②

Mono-manifold/MF532M (5-port)■Direct screw piping type

■With one touch fittings

Note) For a wiring method other than that shown above, see dimensions of each valve.

Note) For a wiring method other than that shown above, see dimensions of each valve.

④ ④ ④

④ ④ ④

CAD/DATAis available.SR532/TSR532K

CAD/DATAis available.SR532/TSR532K

Page 16: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR332/SR532SR332/SR532 SR2/RB

30VA

Unit: mm

S2 S2

S1S1

SR532-DNO*RKSR532-CNO*RK

SR532-RNO*RKSR532-RNO*RK

Seal plateMF532-ES

stn.1 stn.2 stn.3 stn.4 stn.5

23

13

20 32

7

2×3-Rc1/8(With 3 plugs: temporarily tightened)

24

61.2

33463016

1541

69.2

181183

43Approx. 300

4-φ4.2(Mounting holes)

M5×0.8

3 3 3

5

5

3159.2

21.5

Manual overrideNon-lock type

LP 3.5

1616 16 1615158.5

3.5

438.8 for φ49.5 for φ6

One touch fitting

5

5

1.81.8

⑤④②

P

L

2

41

48

4

73

80

6

105

112

8

137

144

10

169

176

Table of Dimensions of Manifold

Easy-manifold/MF532E (5-port)■Direct screw piping type

With one touch fittings

Note: PR is on the port side ②④.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type andDIN socket type valves, see dimensions of each valve.

④ ④ ④ ④

②②②②

SymbolNo. of stations

CAD/DATAis available.SR532/TSR532K

Page 17: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

32VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

33VA

Small-size lubrication-free solenoid valves having a valve width of 18 mm and effective sectional area of 10.2 mm² (2-position type)●Suitable for driving cylinders with bores of up to 50 mm●As standard devices for protection from power surge, the valves for AC are provided with varistors, and those for DC are provided with flywheel diodes.

●The valves for AC power supply are applicable to 100 V AC to 120 V AC or 200 V AC to 240 V AC.

●The valves can be wired by various methods, e.g. Q socket, P socket, DIN socket and lead wire methods, and the Q socket, P socket and DIN socket type valves are provided with indicating lamps for easy confirmation as standard devices.

●Valves with one touch fittings for 4- and 6-mm dia. tubes are standardized.●Compact tandem valves of double solenoid type are available (sub-plate type/Mono-manifold type/24 V DC).

Lubrication

Working pressure range

Working fluid

Proof test pressure

Working temperature range

Manual Override

Installing direction

Vibration resistance/impact resistance

Recommended lubricant

JIS symbol

Model number

Item

3-port

2-position

Normally closed

SR342-NN1

SR342-NMM

SR342-ON1

SR342-OMM

SR542-RN1

SR542-RMM

SR542-DN1

SR542-DMM

SR542-CN1

SR542-CMM

SR542-EN1

15/20 ms or less

15/15 ms or less

15/20 ms or less

15/15 ms or less

15/35 ms or less

15/20 ms or less

15 ms or less

15 ms or less

95

105(250)

105

115(275)

155165(325)     Tandem type 135(295)

190

200(360): Tandem type150(310)

SR542-EMM

1373.0 m/s2 (294.2 m/s² in axial direction) 294.2 m/s2

SR542-PN1

SR542-PMM

Directtype

P・A・B

R1・R2

Sub-platetype

P・A・B

R1・R2

Normally open

5-port

2-position

Return Detent

Direct screw piping type: Rc1/8With one touch fittings: φ4 and φ6 (tube outer dia.)

Direct screw piping type: Rc1/4

3-position3-position closed center

Direct typeEasy-manifoldSub-plate typeMono-manifold

Direct typeEasy-manifoldSub-plate typeMono-manifold

3-position exhaust center

3-position pressure center

Model

Valve Specifications

Air

Unnecessary

0.15 to 0.7 MPa

1.05 MPa

+5 to +50℃ (ambient temperature and fluid temperature)

Pushing

Free

JIS K2213 Class 1 (additive-free turbine oil ISO VG32) or its equivalent

Note 1) Values at an air pressure of 0.5 MPa. The values were obtained at the opposite positions in the case of 2-position valves or in the valve neutral state in the case of 3-position valves.

Note 2) The parenthesized weight includes the weight of the sub-plate.

Port size

Note 1)Response timeIn ON/OFF state

Note 2)Weight g

24 V DC, 12 V DC

100 V AC, 200 V AC

Effective sectional area

10.2 mm2 9.0 mm2

8.2 mm2 8.2 mm2

DirectSub-plateSub-plate/tandem type

2

13

2

13

(A) (A)

(P)(R) (P)(R)

42

13 5

42

13S1 S2

5

42

S1 S213 5

42

S1 S213 5

42(A)(B) (A)(B) (A)(B) (A)(B) (A)(B)

S1 S213 5

(P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1) (P)(R2)(R1)

Type

Allowable circuit leakage current value

Insulation resistance MΩWiring method and lead wire length

Note) Lead wire color

Color of LED indicatorMeasures against surge(standard device)

Frequency Hz

Starting mA(r.m.s)

Exciting mA(r.m.s)

12 V DC

140(1.7W)

8

Flywheel diode against surgeBuilt-in surge

absorbing transistor

Red

Flywheel diode

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

For 12 V DC and 24 V DC For 100 V AC and 200 V AC 24 V DC (tandem solenoid)

Lead wire type

Ele

ctric

circ

uit

Q socket type

P socket type

DIN socket type

10.8 to 13.2

(12±10%)

Brown : +Black : -

24 V DC (tandem solenoid)

50(1.2W)

2

Red

Surge absorbing transistor

21.6 to 26.4

(24±10%)

Red(SA) Black(COM)White(SB)

100 V AC

4

100 or more

50

36

24

60

32

20

Shading type

Varistor

Yellow

90 to 132

(100  %)

Yellow

24 V DC

75(1.8W)

4

21.6 to 26.4

(24±10%)

Red : +Black : -

Rated voltage

Electrical Specifications

Note) The 1 and 3m lead wires (1L and 3L, optional) of the P socket and Q socket type valves are in red and black.

Current value (when rated voltage is applied)

+32-10

200 V AC

2

50

18

12

60

16

10

Green

180 to 264

(200  %)

White

+32-10

Lead wire type: 300 mm, P/Q socket type: 300 mm (standard) P/Q socket type: 300 mm (standard)

(+)

(-)

Lead wire 12 V DC: Brown24 V DC:  Red

Flywheeldiode

Lead wire: Black

Short-circuit preventing diode

Solenoid

Lead wire 100 V AC: Yellow200 V AC: White

VaristorSolenoid

□(-)

Lead wire 12 V DC: Brown24 V DC:  Red

Lead wire: Black

LED indicator(LED)

LED indicator, red

Lead wire  100 V AC: Yellow

200 V AC: White

LED indicator(LED)

LED indicator color 100 V AC: Yellow200 V AC: Green

Diode

SOL.A (SA): Red COM: Black

SOL.B (SB): White

S2

S1

DIN□(+)2

1

mA

Working voltagerange V

Page 18: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

34VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

35VA

Name

Type

Model number

Max. number of stations

Standard number of stations

Exhaust type

Port size

Piping specification

Easy-manifold

Common exhaust type

Rc1/4

MF342M・MF542M

20 stations

2・4・6・8・10

Direct screw piping type

Manifold Specifications

P・R1・R2

A・B

With one touch fittings

Side piping

Rc1/8 φ4・φ6

Easy-manifold

MF342E・MF542E

20 stations

2・4・6・8・10

Direct screw piping type With one touch fittings

Front piping (piping on valve side)

Rc1/8(piping on valve side) φ4・φ6

Model number

Weight g

Item

3-port

2-position

Normally closed

SR342-NN1

SR342-NMM

SR342-ON1

SR342-OMM

SR542-RN1

SR542-RMM

SR542-DN1

SR542-DMM

SR542-CN1

SR542-CMM

SR542-EN1

95

105(250)

105

115(275)

155 190

200(360): Tandem type150(310)

SR542-EMM

SR542-PN1

SR532-PMM

Normally open

5-port

2-position

Return Detent

3-position3-position closed center

Direct typeEasy-manifoldSub-plate typeMono-manifoldDirect typeEasy-manifoldSub-plate typeMono-manifold

3-position exhaust center

Model

Valve Weight

●The parenthesized weight includes the weight of the sub-plate.

Unit: g

2 4 6 8 10

Mono-manifold

Easy-manifold

Mono-manifold

Easy-manifold

MF342M-**A

MF342M-**C

MF342M-**E

MF342E-**S

MF542M-**A

MF542M-**C

MF542M-**E

MF542E-**S

Manifold Weight Unit: g

Name

No. of stations

●Add the valve weight to the manifold weight.

216

232

228

94

360

390

396

124

360

392

384

158

600

660

672

208

504

552

540

222

840

930

948

292

646

712

696

286

1080

1200

1224

376

792

872

852

350

1320

1470

1500

460

165(325)     Tandem type 135(295)

3-position pressure center

Effective sectional area 10.2 mm²

00.1

200 400 600 1000800

0.20.30.40.50.60.7MPa

Valve outlet pressure

Valve outlet pressure

Flow rate ℓ/min(ANR) Flow rate ℓ/min(ANR)

0.20.3 0.4

0.5

Supply pressureMPa

0.1

0.60.7

Effective sectional area 9.0 mm²

00.1

200 400 600 1000800

0.20.30.40.50.60.7MPa

0.20.30.40.5

0.1

0.60.7

Flow Characteristic Curves

How to read the chartWhen the flow rate is 460 ℓ/min (ANR) at a supply pressure of 0.5 MPa, the valve outlet pressure is 0.4 MPa.

Supply pressureMPa

Page 19: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

36VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

37VA

■How to order (3-port)●Model number of valve onlyDirect type (port size Rc1/8)Easy-manifold

SR342- N N1 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plate

Sub-plate type (port size Rc1/4)Mono-manifold

SR342- N MM 1Series

Sub-plateNo symbol: NoneSP: With sub-plate

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red and black.

Wiring methodWiring methodVoltage Symbol

Lead wire typeWith protective circuit

RK

Voltage (standard)

Voltage (option)

Symbol

100 V AC   %(Lead wire color: yellow)

1N1

Q socket typeWith indicating lamp/protective circuit

P socket typeWith indicating lamp/protective circuit

DIN socket typeWith indicating lamp/protective circuit

QW

PW

DW

Switching methodSwitching methodSymbol

Normally closed

N

Normally open

O

+32-10

200 V AC   %(Lead wire color: white)

2+32-10

8

6

Other voltages9

Port sizePort size (standard)

Port size (option)

Symbol

Direct screw piping typeRc1/8

MMFor sub-plate/mono-manifold

VAOD of tube with joint on secondary side φ4

VBOD of tube with joint on secondary side φ6

WAOD of tube with joints on both sides φ4

WBOD of tube with joints on both sides φ6

Note) The valve will be delivered without the sub-plate mounted.

RK - 1L - SP

2

13

2

(A)

(A)

13

(P)(R)

(P)(R)

24 V DC ±10%(Lead wire color: + red, - black)◯◯

12 V DC ±10%(Lead wire color: + brown, - black)◯ ◯

■How to order manifold●Model number of Mono-manifold

MF342M- 04 ASeries

■How to order valve for manifold●Mono-manifold

SR342- N MM 1 QW - 1L

■How to order seal plate SZZ

MF342-MS (For Mono-manifold)MF342-ES (For Easy-manifold)

Series For Mono-manifold

No. of manifold stationsNo. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Piping methodPiping methodSymbol

Side piping (direct screw piping type)

Side piping (with one touch fittings: φ4)

Side piping (with one touch fittings: φ6)

A

C

E

●Model number of Easy-manifold

MF342E- 04 SSeries

No. of manifold stationsNo. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Note) For details, see “How to order valve only”.

●Easy-manifold

SR342- N N1 1 QW - 1LSeries

Port sizeN1:Direct screw piping type(Rc1/8)VA:With one touch fittings(φ4)VB:With one touch fittings(φ6)Note) For details, see “How to order valve only”.

●Easy-manifold■How to order manifold

 ●A 4-station Mono-manifold type is shown as follows.  ●Manifold body   MF342M-04A  ●Valve block   SR342-NMM1RK   SR342-OMM1RK

Qty.1

22

●A 4-station Easy-manifold type is shown as follows. ●Manifold body  MF342E-04S ●Valve block  SR342-NN11RK  SR342-ON11RK

SR342-NMM1RKSR342-OMM1RK

PR

SR342-NN11RKSR342-ON11RK(A)2

●Mono-manifold

■How to order gasket and bolt set SZZ

MF342-MGBS (For Mono-manifold)MF342-EGBS (For Easy-manifold)

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

3(R)1(P)

2(A)

3(R)1(P)

Qty.1

22

Page 20: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

38VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

39VA

■How to order valve only (5-port)●Model number of valve onlyDirect type (port size Rc1/8)Easy-manifold

SR542- R N1 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plateNote) Only return type

Sub-plate type (port size Rc1/4)Mono-manifold

SR542- R MM 1 RK - 1L - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red and black.

Wiring methodSwitching methodSwitching methodSymbol

Return

R

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

Note) The valve will be delivered without the sub-plate mounted.

P

42

13 5

(A)(B)

(P)(R2)(R1)

42

13S1 S25

(A)(B)

(P)(R2)(R1)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)

42(A)(B)

S1 S213 5(P)(R2)(R1)

Wiring methodSymbol

Lead wire typeWith protective circuit

RK

Q socket typeWith indicating lamp/protective circuit

P socket typeWith indicating lamp/protective circuit

DIN socket typeWith indicating lamp/protective circuit

QW

PW

DW

VoltageVoltage (standard)

Voltage (option)

Symbol

100 V AC   %(Lead wire color: yellow)

1+32-10

200 V AC   %(Lead wire color: white)

2+32-10

8

6

Other voltages9

24 V DC ±10%(Lead wire color: + red, - black)◯◯

12 V DC ±10%(Lead wire color: + brown, - black)◯ ◯

N1

Port sizePort size (standard)

Port size (option)

Symbol

Direct screw piping typeRc1/8

MMFor sub-plate/mono-manifold

VAOD of tube with joint on secondary side φ4

VBOD of tube with joint on secondary side φ6

WAOD of tube with joints on both sides φ4

WBOD of tube with joints on both sides φ6

■How to order valve only (5-port)●Model number of valve onlyTandem solenoid (port size Rc1/4)Mono-manifold

SR542- D DM 8 QW - 1D - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Tandem type

Lead wire lengthNo symbol: Standard (300 mm)1D: 1000 mm (order made)3D: 3000 mm (order made)Note) The lead wires are in red,

white and black.

Wiring methodWiring methodVoltage Symbol

VoltageSymbol

Q socket typeWith indicating lamp/protective circuit

P socket typeWith indicating lamp/protective circuit

QW

PW

Switching methodSwitching methodSymbol

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

24 V DC ±10%(Lead wire color: SA: red, SB: white, COM: black)

8

Note) The valve will be delivered without the sub-plate mounted.

P

42

13S1 5

(A)(B)

(P)(R2)(R1) S2(SB) (SA)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)(SB) (SA)

42

S1 S213 5

(A)(B)

(P)(R2)(R1)(SB) (SA)

42(A)(B)

S1 S2(SB) (SA)

13 5(P)(R2)(R1)

Page 21: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

40VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

41VA

How to order manifold●Model number of Mono-manifold

MF542M- 04 ASeries

How to order valve for Mono-manifold●Single/double solenoid

SR542- R MM 1 QW - 1L

MF542-MS

Series For Mono-manifold

No. of manifold stations

02

04

06

08

10

Piping methodSymbol

A

C

E

●Tandem solenoid

SR542- D DM 8 QW - 1DSeries Tandem type

Note) For details, see “How to order valve only”.

■How to order seal plate SZZ

■How to order gasket and bolt set SZZ

How to order Mono-manifold(5-port)

 ●A 4-station Mono-manifold is shown as follows. ●Manifold body  MF542M-04A ●Valve block  SR542-CMM1RK  SR542-DMM1RK  SR542-RMM1RK

Qty.1

112

 ●A 4-station Mono-manifold is shown as follows. ●Manifold body  MF542M-04C ●Valve block  SR542-CMM1RK  SR542-DMM1RK  SR542-RMM1RK

SR542-CMM1RK

SR542-DMM1RK

SR542-RMM1RK

PR1

PR1

PR2Side piping(direct screw piping type)

SR542-CMM1RK

SR542-DMM1RK

SR542-RMM1RK

Side piping (with one touch fittings: φ4)

PR2

MF542-MGBS

5(R1)1(P)3(R2)

5(R1)1(P)3(R2)

No. of stationsSymbol

2 stations

4 stations

6 stations

8 stations

10 stations

Piping method

Side piping (direct screw piping type)

Side piping (with one touch fittings: φ4)

Side piping (with one touch fittings: φ6)

Qty.1

112

How to order manifold●Model number of Easy-manifold

MF542E- 04 SSeries

How to order valve for Easy-manifold

02

04

06

08

10

●Single/double solenoid

SR542- R N1 1 QW - 1LSeries

Port sizeN1:Direct screw piping type(Rc1/8)VA:With one touch fittings(φ4)VB:With one touch fittings(φ6)Note) The above three port sizes are available.

Note) For details, see “How to order valve only”.

MF542-ES

How to order Easy-manifold(5-port)

 ●A 4-station Easy-manifold is shown as follows. ●Manifold body  MF542M-04A ●Valve block  SR542-CMM1RK  SR542-DMM1RK  SR542-RMM1RK

Qty.1

112

SR542-CN11RK

SR542-DN11RK

SR542-RN11RK

Model numberTube OD

M4-01M

M6-01M

F8-01MS

φ4

φ6

φ8

For Rc1/8

●One touch fittings

MF542-EGBS

■Related products/Joints and silencers More compact piping is enabled.

Model numberModel number

For M5 For Rc1/8

SA2-M5 SA2-06(G1/8)

Model number

For Rc1/4

SA2-08(G1/4)

●Silencer

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

5(R1)1(P)3(R2)

(A)4

(B)2No. of manifold stations

02

No. of stationsSymbol

2 stations

4 stations

6 stations

8 stations

10 stations

■How to order gasket and bolt set SZZ

■How to order seal plate SZZ

Page 22: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

42VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

43VA

Unit: mm

(A)23(R)1(P) (A)2

3(R)1(P)

PR

Solenoid cover

PlungerPlunger spring

Manual buttonPiston

Main body

End cover

Plunger pin

Mold solenoid

Column

Main shaft

Lip seal

FlapperPilot valve body

Shading coil(only AC solenoid)

Spring

(A)23(R)

1(P)

PR

(A)23(R)

1(P)

Valve

Manifold

Main body

Main shaft

Lip seal

Flapper

Mounting base

Sub-base

Plunger

Column

Main body

Block plate

Seal

Aluminum alloy (alumite)

Synthetic rubber (NBR)

Mild steel (galvanized)

Aluminum alloy (alumite)

Aluminum alloy (alumite)

Mild steel (nickel-plated)

Synthetic rubber (NBR)

Electromagnetic stainless steel

Name Material

Materials of Major Parts

S2

S1

(A)4(B)2

5(R1)

3(R2)1(P)

PR1

S2

PR2

(A)4

(B)2

5(R1)

3(R2)

1(P)

(A)4(B)2

5(R1)

3(R2)1(P)

PR1

S2

S1

PR2

(A)4

(B)2

5(R1)

3(R2)

1(P)

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

PR

(A)4

(B)2

5(R1)

3(R2)

1(P)

Sectional Drawings■3-port Normally closed

(NC)Normally open(NO)

Return Detent

SR542- RN1In non-energized state

SR542- DN1

SR542- CN1

■5-port 2-position ■5-port 3-position

Normally closed

SR342-NN1(Normally closed)

In non-energized state

SR342-ON1(Normally open)

In non-energized state

2-M3×0.5 depth 4Mounting screw holes

9.59.5

5 5

0.5

6.5 6.5

Manual buttonNon-lock type

2-φ3.2 spot facing φ6 depth 3(Mounting holes)

3-Rc1/8

18

26.420

14.4

58.686.8

2-φ3.2 (Mounting holes)

PR

A

<View A>

20

14.4

20

19.432.6

Approx. 300 24

27

① ②

PR

123248

25

3-Rc1/4

M5×0.8

15 18 27 34

3.5

3.5

58.6

86.8

7 35

32.4522.4

2-φ4.5 (Mounting holes)

Manual buttonNon-lock type

Approx. 300

12

24

30

27

58

24

12③ ①

PR1

S2

S1

PR2

(A)4

(B)2

5(R1)

3(R2)

1(P)

PR1

S2

S1

PR2

(A)4

(B)2

5(R1)

3(R2)

1(P)

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

S1

S2

(A)4(B)2

5(R1)

3(R2)1(P)

■Sub-plate type●SR342ーNMM Voltage RK ー SP (Normally closed)●SR342ーOMM Voltage RK ー SP (Normally open)

■Direct type●SR342ーNN1 Voltage RK (Normally closed)●SR342ーON1 Voltage RK (Normally open)

3-port/normally closed and normally open

Note) The valve will be delivered without the sub-plate mounted.

SR542- EN1

Exhaust center

SR542- PN1

Pressure center

CAD/DATAis available.SR342/TSR342A(B)

Page 23: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

44VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

45VA

Unit: mm Unit: mm

PR

29.4

26.4

16.2

24Approx. 300

27

21

30

14.4

2-φ3.2 Mounting holes

15

18

Manual overrideNon-lock type 2-φ3.2 spot facing φ6 depth 3(Mounting holes)

5-Rc1/80.56.5 6.5

0.5

16

21.4

2-M3×0.5 depth 4Mounting screw holes

9.5

9.5

5 5

0.50.5

30

14.4

68.696.8

A

<View A>

⑤ ① ④

PR1

PR2

18

15

27 3.53.5

34

10

25.545.5

Manual overrideNon-lock type

2-φ4.5 (Mounting holes)

32

25.5

7174.7102.9

Approx. 300 24 2515

10

27 30

58

35.515.5

40 62

4.5

5-Rc1/4

2-M5×0.8

① ④

2-PR

13.213.2

24Approx. 300

27

21

1515

2-φ3.2 (Mounting holes)

15

18

2-manual overridesNon-lock type

5-Rc1/8

6.5 6.5

8

8

1515

67.4

39.2

134.8

S2

S1

⑤ ① ④

④ PR1

PR2

S2

S1

18

15

27 3.53.5

34

10

25.545.5

2-manual overridesNon-lock type

2-φ4.5 (Mounting holes)

32

25.5

78.4

28.2

134.8

Approx. 300 24 2515

10

27 30

58

35.515.5

40 62

4.52-M5×0.85-Rc1/431.9

71

① ④

2-PR

13.213.2

24約300

27

21

1515

15

18

5-Rc1/8

0.5 0.5

6.5 6.5

8

8

1515

80.4

70.2

52.2

42

150.6

S2

S1

⑤ ① ④

PR1

PR2

S2

S1

18

15

27 3.53.5

34

10

25.545.5

2-φ4.5

32

25.5

94.2

28.2

150.6

Approx. 300 24 25

15

10

27 30

58

35.515.5

40 62

4.52-M5×0.85-Rc1/4

44.9

71

34.7

① ④

■Direct type●SR542ーRN1 Voltage RK (return)

■Sub-plate type●SR542ーRN1 Voltage RKーSP (return)

●SR542ーDN1 Voltage RK (detent) ●SR542ーDMM Voltage RKーSP (detent)

●SR542ーCN1 Voltage RK (closed center)●SR542ーEN1 Voltage RK (exhaust center)●SR542ーPN1 Voltage RK (pressure center)

●SR542ーCMM Voltage RKーSP (closed center)●SR542ーEMM Voltage RKーSP (exhaust center)●SR542ーPMM Voltage RKーSP (pressure center)

5-port/2-poition and 3-position

Note) The valve will be delivered without the sub-plate mounted.

0.5 0.5

2-φ3.2 spot facing φ6 depth 3(Mounting holes)

2-φ3.2 (Mounting holes)

2-manual overridesNon-lock type 2-φ3.2 spot facing φ6 depth 3(Mounting holes)

2-manual overridesNon-lock type

(Mounting holes)

2-φ4.5 (Mounting holes)

1.6

26

5

91.8 (to valve upper surface)

16.5 16.5

45

1.6

26

5

101.8 (to valve upper surface)

16.5 16.5

2-φ4.5 (Mounting holes)

45

Rc1/8One touch fittings

26.4

7.8 for φ48.5 for φ6

7.8 for φ48.5 for φ6

① ②

0.5 0.5

2-Rc1/8

22.4

14

7.8 for φ48.5 for φ6

7.8 for φ48.5 for φ6

One touch fittings

① ④

36A

10

35.5

LEDindicator

29B

20.5

46

LEDindicator

55.5(2.4) Pg7

(27) (34.5) (44.1)

7.5

C

13

φ14.8

SR342-*N0**

SR542-RN1**

SR542-RMM**-SP

SR542-DN1**, SR542-DMM**-SP

SR542- (C, E, P) N1**SR542- (C, E, P) *M**-SP

94.6

104.6

110.7

150.4

166.2

Standard type: 300 mm

Order made:

1L: 1000 3L: 3000

1D: 1000 3D: 3000

(For tandem solenoid)

Overall length to valve or

sub-base end face

Overall length to solenoid

end face on opposite side

87.6

97.6

103.7

136.4

152.2

102.7

112.7

118.8

166.6

182.4

Model number Symbol A

Dimensional TableB C (lead wire length) Remarks

Option■Mounting plate SZZ SR542-F●3-port valve mounting dimensions ●5-port valve mounting dimensions (only return type)

Note) The valve will be delivered without the mounting plate mounted.

■With one touch fittings●3-port valve dimensions ●5-port valve dimensions

■Wiring method●Q socket type ●P socket type ●DIN socket type

CAD/DATAis available.SR542/TSR542A(B)

CAD/DATAis available.SR542/TSR542A(B)

Page 24: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

46VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

47VA

Unit: mm Unit: mm

A

A B

B

DC24V

40 6232

25.5

7172.6

100.6108.8114.9

182-LED indicators

2734

Approx. 300

7342 30

2515

2-M5×0.8

3-RC1/4

10

20

10

37.5

Manual override

2-φ3.2 (Mounting holes)φ6 deep spot facing depth 4

2-φ4.5(Mounting holes)

2-RC1/4

PR1

PR2 ③

① ④

A

A BC

A B

B

DC24V

Approx. 300

40 6232

25.5

7172.6

100.6106.7

182734

83.852.8

2530

15

2-M5×0.8

3-RC1/4

10

20

10

2-φ4.5(Mounting holes)

2-RC1/4

PR1

PR2 ③

① ④

●SR542ーDDM Voltage QWーSP (detent)

●SR542ーDDM Voltage PWーSP (detent)

5-port/tandem solenoid (2-position)

Note) The valve will be delivered without the sub-plate mounted.

2-LED indicatorsManual override

2-φ3.2 (Mounting holes)φ6 deep spot facing depth 4

A

A B

B

DC24V

40 6232

25.5

7184.8

112.8121

182-LED indicators

2734

Approx. 300

7342 30

2515

2-M5×0.8

3-RC1/4

10

20

6.1

10

37.5

Manual override

2-RC1/4

PR1

PR2 ③

① ④

A

A BC

A B

B

DC24V

Approx. 300

40 6232

25.5

71

182-LED indicators 27

34

83.852.8 30

2515

2-M5×0.8

3-RC1/4

10

20

10

Manual override

2-φ4.5(Mounting holes)

2-RC1/4

PR1

PR2

84.8112.8

6.1 ③

① ④

●SR542ーCDM Voltage QWーSP (closed center)●SR542ーEDM Voltage QWーSP (exhaust center)●SR542ーPDM Voltage QWーSP (pressure center)

●SR542ーCDM Voltage PWーSP (closed center)●SR542ーEDM Voltage PWーSP (exhaust center)●SR542ーPDM Voltage PWーSP (pressure center)

Note) The valve will be delivered without the sub-plate mounted.

5-port/tandem solenoid (3-position)

2-φ4.5(Mounting holes)2-φ3.2 (Mounting holes)

φ6 deep spot facing depth 4

2-φ3.2 (Mounting holes)φ6 deep spot facing depth 4

Page 25: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

48VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

49VA

Unit: mm Unit: mm

L

P

018101 18

19 19 19 19

5Manual overrideNon-lock type

5

2.4

86.8

4-φ4.2 (Mounting holes)

SR332-*MM*RKSR332-*MM*RK

Seal plateMF342-MSRc1/8

8

21 19stn.1 stn.2

50

20

4.5

52PR

58

27 28

2424

17

10

1534 46

② ② ②

L

P

018101 18

19 19 19 19

5Manual overrideNon-lock type

5

2.4

86.8

SR342-*MM*RKSR342-*MM*RK

Seal plateMF342-MSOne touch fittings

8

21 19stn.1 stn.2

50

20

4.5

52PR

58

27 28

2424

17

10

Approx. 300

1534 46

2×1-M5×0.8 (With 1 plug: temporarily tightened)

2×2-Rc1/4 (With 2 plugs: temporarily tightened)

4.8 for φ45.5 for φ6

② ② ②

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

Mono-manifold/MF342M(3-port)■Direct screw piping type

■With one touch fittings

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

Approx. 300

4-φ4.2 (Mounting holes)

2×1-M5×0.8 (With 1 plug: temporarily tightened)

2×2-Rc1/4 (With 2 plugs: temporarily tightened)

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

SymbolNo. of stations

SymbolNo. of stations

L

P

Rc1/8

018101 18

19 19 19 19

5Manual overrideNon-lock type

5

2.4

26.4

86.8

2-φ4.2 (Mounting holes)

SR342-*N1*RKSR342-*N1*RK

Seal plateMF342-ES

stn.1 stn.2

32

1938

53

27

2524

11

5

Approx. 300

16

5

929

7.8 for φ48.5 for φ6 53

One touch fittings

26.4

Easy-manifold/MF342E(3-port)■Direct screw piping type

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

With one touch fittings

② ②

2×2-Rc1/4 (With 2 plugs: temporarily tightened)

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of ManifoldSymbol

No. of stations

CAD/DATAis available.SR342/TSR342K

CAD/DATAis available.SR342/TSR342K

Page 26: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

50VA

Small-size Solenoid Valve SR342/SR542SR2/RB SR342/SR542

51VA

Unit: mm Unit: mm

4-φ4.2 (Mounting holes)

SR542-DMM*RKSR542-CMM*RK

SR542-RMM*RKSR542-RMM*RK

2-Rc1/8 (for 1 station) Seal plate

MF542-MS

stn.1 stn.2 stn.3 stn.4 stn.56 2

8

25

16.5344027

68

3740

17

PR1

PR2

62

6

24Approx. 300

LP 5

1919 19

S2 S2

S1S1

80.4

70.242

746820

27 52.2

191810

1518

5

39.267.4

29.4

Manual overrideNon-lock type

⑤ ①

④ ④

SR542-DMM*RKSR542-CMM*RK

SR542-RMM*RKSR542-RMM*RK

2-one touch fittings(for 1 station) Seal plate

MF542-MS

stn.1 stn.2 stn.3 stn.4 stn.56 2

7

25.5

16.5344027

68

3740

17

P

PR1

PR2

62

6

24Approx. 300

LP 5

1919 19

S2 S2

S1S1

80.4

70.2

427468

20

27 52.2

191810

1518

5

39.267.4

29.4

Manual overrideNon-lock type

4-φ4.2 (Mounting holes)

4.8 for φ45.5 for φ6

⑤ ①

④ ④

Mono-manifold/MF542M(5-port)■Direct screw piping type

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

② ② ②

② ②

2×2-M5×0.8 (With 2 plugs: temporarily tightened)

2×3-Rc1/4 (With 3 plugs: temporarily tightened)

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

■With one touch fittings

2×2-M5×0.8 (With 2 plugs: temporarily tightened)

2×3-Rc1/4 (With 3 plugs: temporarily tightened)

SymbolNo. of stations

SymbolNo. of stations

A

A

ADC24V

C B

B

B

A

A

ADC24V

C B

B

B

39.267.4

Manual overrideNon-lock type

29.4

70.242.5

746820.5

42.5

4-φ4.2 (Mounting holes)

20

27

LP 5

1919 19 191818

1510

5

SR542-DDM*PWSR542-CDM*PW

SR542-RMM*RKSR542-RMM*RK

2-Rc1/8 (for 1 station) Seal plateMF542-MS

stn.1 stn.2 stn.3 stn.4 stn.56 2

8

25

16.53440

93.8

52.8Approx. 300

37

40

17

PR1

PR2

62

6

A

A

ADC24V

C B

B

B

A

A

ADC24V

C B

B

B

39.267.4

Manual overrideNon-lock type

29.4

70.242

746820.5

43

4-φ4.2 (Mounting holes)

20

27

LP 5

1919 19 191818

1510

5

SR542-DDM*PWSR542-CDM*PW

SR542-RMM*RKSR542-RMM*RK

2-one touch fittings(for 1 station)

Seal plateMF542-MS

stn.1 stn.2 stn.3 stn.4 stn.56 2

7

25.5

16.53440

93.8

52.8Approx. 300

37

40

17

PR1

PR2

62

64.8 for φ45.5 for φ6

Mono-manifold/MF542M(5-port)

④ ④ ④

④④

② ② ②

② ② ②

④ ④

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of Manifold

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

■Direct screw piping type

■With one touch fittings

2×2-M5×0.8 (With 2 plugs: temporarily tightened)

2×3-Rc1/4 (With 3 plugs: temporarily tightened)

2×2-M5×0.8 (With 2 plugs: temporarily tightened)

2×3-Rc1/4 (With 3 plugs: temporarily tightened)

SymbolNo. of stations

SymbolNo. of stations

CAD/DATAis available.SR542/TSR542K

CAD/DATAis available.SR542/TSR542K

Page 27: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

Small-size Solenoid ValveSR342/SR542SR342/SR542 SR2/RB

52VA

Unit: mm

8 7

8

39.267.4

29.4

Manual overrideNon-lock type

70.2

42584220

1952.2

80.4

4-φ4.2 (Mounting holes)

S1

S2

S1

S2

Rc1/8

0.5 0.5

LP 5

1919 19 191818

1510

5

SR542-DN1*RKSR542-CN1*RK

SR542-RN1*RKSR542-RN1*RK

Seal plateMF542-ES

stn.1 stn.2 stn.3 stn.4 stn.5

29

18

22 40

9

27 251624117

53Approx. 300

⑤ ④ ④ ④

② ② ②

537.8 for φ48.5 for φ6

One touch fittings

7

7

0.50.5

⑤ ①

④ ④

② ②

Easy manifold/MF542E(5-port)■Direct screw piping type

Note) The above drawings show dimensions of the lead wire type valve. For the Q/P socket type and DIN socket type valves, see dimensions of each valve.

With one touch fittings

2×3-Rc1/4 (With 3 plugs: temporarily tightened)

P

L

2

47

57

4

85

95

6

123

133

8

161

171

10

199

209

Table of Dimensions of ManifoldSymbol

No. of stations

CAD/DATAis available.SR542/TSR542K

Page 28: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR552SR552 SR2/RB

Small-size Solenoid Valve54VA

SR552SR2/RB SR552

Small-size Solenoid Valve 55VA

SR552-RN2

SR552-RMM

SR552-DN2

SR552-DMM

SR552-CN2

SR552-CMM

SR552-EN2

15/30 ms or less

15/25 ms or less

15 ms or less

15 ms or less

20/25 ms or less

15/20 ms or less

230

240(460)

380

390(610)

SR552-EMM

1373.0 m/s2

(343.2 m/s2 in axial direction)1373.0 m/s2

(245.2 m/s2 in axial direction) 1373.0 m/s2 (441.3 m/s2 in axial direction)

SR552-PN2

SR552-PMM

5-port

2-position

Direct screw piping type: Rc1/4

Direct screw piping type: Rc1/4

3-position

Air

Unnecessary

0.17 to 0.7 MPa

1.05 MPa

+5 to +50℃ (ambient temperature and fluid temperature)

Pushing

Free

JIS K2213 Class 1 (additive-free turbine oil ISO VG32) or its equivalent

Note 1) Values at an air pressure of 0.5 MPa. The values were obtained at the opposite positions in the case of 2-position valves or in the valve neutral state in the case of 3-position valves.

Note 2) The parenthesized weight includes the weight of the sub-plate.

330

330(550)

AB

PR2 R1

AB

PR2 R1S1 S2

AB

S2S1PR2 R1

AB

S2S1 PR2 R1

AB

S2S1PR2 R1

Valve Specifications

22 mm2

20 mm2

25 mm2

22 mm2

Small-size lubrication-free solenoid valves having a valve width of 21 mm and effective sectional area of 25 mm² (2-position type)●Suitable for driving cylinders with bores from 63 to 100 mm●As standard devices for protection from power surge, the valves for AC are provided with varistors, and those for DC are provided with flywheel diodes.●The valves for AC power supply are applicable to 100 V AC to 120 V AC or 200 V AC to 240 V AC.●The valves can be wired by various methods, e.g. Q socket, P socket, DIN socket and lead wire methods, and the Q socket, P socket and DIN socket type valves are provided with lamps for easy confirmation as standard devices.

Lubrication

Working pressure range

Working fluid

Proof test pressure

Working temperature range

Manual override

Installing direction

Vibration resistance/impact resistance

Recommended lubricant

JIS symbol

Model number

Item

Directtype

P・A・B

R1・R2

Sub-platetype

P・A・B

R1・R2

Direct typeEasy-manifoldSub-plate typeMono-manifold

Direct typeEasy-manifoldSub-plate typeMono-manifold

Model

Port size

Note 1)Response timeIn ON/OFF state

Note 2)Weight g

24 V DC, 12 V DC

100 V AC, 200 V AC

Effective sectional area

DirectSub-plateSub-plate/tandem type

Return Detent 3-position closed center 3-position pressure center3-position exhaust center

□(-)

12 V DC

140(1.7W)

8

Flywheel diode against surge

Red

Flywheel diode

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

10.8 to 13.2

(12±10%)

Brown : +Black : -

100 V AC

100 or more

Lead wire type: 300 mm, P/Q socket type: 300 mm (standard)

50

55

24

60

49

19

Shading type

Varistor

Yellow

90 to 132

(100  %)

Yellow

24 V DC

75(1.8W)

4

21.6 to 26.4

(24±10%)

Red : +Black : -

RatingItem

Electrical Specifications

Note) The 1 and 3m lead wires (code; 1L and 3L, optional) of the P socket and Q socket type valves are in red and black.

+32-10

200 V AC

24

50

28

12

60

25

10

Green

180 to 264

(200  %)

White

+32-10

(+)

(-)

Lead wire 12 V DC: Brown24 V DC:  Red

Flywheel diode

Lead wire: Black

Short-circuit preventing diode

Solenoid

Lead wire 100 V AC: Yellow200 V AC: White

VaristorSolenoid

Lead wire 12 V DC: Brown24 V DC:  Red

Lead wire: Black

LED indicator(LED)

LED indicator, red

100 V AC: Yellow200 V AC: White

Lead wire

LED indicator(LED)

LED indicator color 100 V AC: Yellow200 V AC: Green

Diode

DIN□(+)

2

1

Type

Allowable circuit leakage current value

Insulation resistance MΩWiring method and lead wire length

Note) Lead wire color

Color of LED indicatorMeasures against surge(standard device)

Frequency Hz

Starting mA(r.m.s)

Exciting mA(r.m.s)

Lead wire type

Ele

ctric

circ

uit

Q socket type

P socket type

DIN socket type

Current value (when rated voltage is applied)

Working voltagerange

mA

V

Page 29: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR552SR552 SR2/RB

Small-size Solenoid Valve56VA

SR552SR2/RB SR552

Small-size Solenoid Valve 57VA

Name

Type

Model number

Max. number of stations

Standard number of stations

Exhaust type

Port size

Piping specification

Mono-manifold

Common exhaust type

Rc3/8

MF552M

10 stations

2・4・6・8・10

Direct screw piping type

Manifold Specifications

P・R1・R2

A・B

Side piping

Rc1/4

Easy-manifold

MF552E

10 stations

2・4・6・8・10

Direct screw piping type

Front piping

Rc1/4 (valve side)

Model number

Item

SR552-RN2

SR552-RMM

SR552-DN2

SR552-DMM

SR552-CN2

SR552-CMM

SR552-EN2

230

240(460)

380

390(610)

SR552-EMM

SR552-PN2

SR552-PMM

5-port

2-position

Return Detent

3-position

Direct typeEasy-manifoldSub-plate typeMono-manifoldDirect typeEasy-manifoldSub-plate typeMono-manifold

3-position exhaust center 3-position pressure center

Model

Valve Weight

Note) The parenthesized weight includes the weight of the sub-plate.

330

330(550)

2 4 6 8 10

Mono-manifold

Easy-manifold

MF552M-**A

MF552E-**S

Manifold Weight Unit: g

Name

No. of stations

1620

270

2680

440

3740

610

4800

780

5860

950

Note) Add the valve weight to the manifold weight.

3-position closed center

Note)Weight g

0.1

00.1

500 1000 1500 2000

0.20.30.40.50.60.7MPa

0.20.30.40.5

0.70.6

0.1

00.1

500 1000 1500 2000

0.20.30.40.50.60.7MPa

0.20.30.40.5

SupplypressureMPa

0.70.6

Flow Characteristic Curves

How to read the chartWhen the flow rate is 1050 ℓ/min (ANR) at a supply pressure of 0.5 MPa, the valve outlet pressure is 0.4 MPa.

Effective sectional area 25 mm² Effective sectional area 22 mm²

Valve outlet pressure

Valve outlet pressure

SupplypressureMPa

Flow rate ℓ/min(ANR) Flow rate ℓ/min(ANR)

Page 30: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR552SR552 SR2/RB

Small-size Solenoid Valve58VA

SR552SR2/RB SR552

Small-size Solenoid Valve 59VA

SR552- R N2 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plateNote) Only return type

Sub-plate type (port size Rc1/4)Mono-manifold

SR552- R MM 1 RK - 1L - SPSeries

Sub-plateNo symbol: NoneSP: With sub-plate

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red and black.

Wiring method (standard)Wiring methodSymbol

Lead wire typeWith protective circuit

RK

Q socket typeWith indicating lamp/protective circuit

QW

P socket typeWith indicating lamp/protective circuit

PW

DIN socket typeWith indicating lamp/protective circuit

DW

Switching methodVoltage

Voltage (standard)

Wiring method (option)

Symbol

Voltage (option)

100 V AC   %(Lead wire color: yellow)

+32-10

200 V AC   %(Lead wire color: white)

+32-10

Other voltages

24 V DC ±10%(Lead wire color: + red, - black)◯◯

12 V DC ±10%(Lead wire color: + brown, - black)◯ ◯

1

2

8

6

9

Return

R

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

AB

PR2 R1

AB

PR2 R1S1 S2

AB

S2S1PR2 R1

AB

S2S1PR2 R1

AB

S2S1PR2 R1

■How to order●Model number of valve onlyDirect type (port size Rc1/4)Easy-manifold

Note) The valve will be delivered without the sub-plate mounted.

Switching methodSymbol

■How to order manifold base●Model number of Mono-manifold

MF552M- 04 ASeries

■How to order manifold valve●Mono-manifold

SR552- R MM 1 QW - 1L

■How to order seal plate SZZ

MF552-MS (For Mono-manifold) MF552-ES (For Easy-manifold)

Series For Mono-manifold

No. of manifold stations

No. of stationsSymbol No. of stationsSymbol No. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Side piping (direct screw piping type)

●Model number of Easy-manifold

MF552E- 04 SSeries

No. of manifold stations

Note) For details, see “How to order valve only”.

For Easy-manifold

Note) For details, see “How to order valve only”.

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

●Easy-manifold

SR552- R N2 1 QW - 1LSeries

●Easy-manifold■How to order manifold

 ●A 6-station Mono-manifold type is shown as follows.  ●Manifold body   MF552M-06A  ●Valve block   SR552-RMM1QW   SR552-CMM1QW

Qty.1

33

Qty.1

33

●A 6-station Easy-manifold type is shown as follows. ●Manifold body  MF552E-06S ●Valve block  SR552-RN21QW  SR552-CN21QW

SR552-CMM1QWSR552-RMM1QW

PR1

PR2

R1

R2

SR552-CN21QW

SR552-RN21QW

R1PR2

 ●Mono-manifold

P

Side piping (direct screw piping type)

MF552-MGBS (For Mono-manifold)MF552-EGBS (For Easy-manifold)

Model numberPort size

SA2-M5

SA2-06

SA2-08

SA2-10

M5

G1/8

G1/4

G3/8

■Related products/Silencers More compact installation is enabled.

No. of stationsSymbol No. of stationsSymbol No. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

■How to order gasket and bolt set SZZ

Page 31: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR552SR552 SR2/RB

Small-size Solenoid Valve60VA

SR552SR2/RB SR552

Small-size Solenoid Valve 61VA

Unit: mm

B

AP

R2

R1

PR

Solenoid coverPlunger

Plunger spring

Piston

Main body

End cover

Plunger pinMold solenoid

Column

Main shaft

Lip seal

Flapper

Pilot valve body

Shading coil(only AC solenoid)

Manual override

R2

R1

PA

B

PR1

PR2

S2

S1

Seal

Flapper

Plunger

Column

Sub-base

Mounting base

Main body

Block plate

Seal

Aluminum alloy (alumite)

Synthetic rubber (NBR)

Aluminum alloy (alumite)

Mild steel (nickel-plated)

Synthetic rubber (NBR)

Electromagnetic stainless steel

Aluminum alloy (alumite)

Mild steel (galvanized)

AB

S1

S2

PR2R1 A

B

S1

S2

PR2R1 A

B

S2

S1

PR2R1

R2

R1

PA

B

PR1

PR2

S2

S1

R2

R1

PA

B

PR1

PR2

S2

S1

R2

R1

PA

B

PR1

PR2

S2

S1

AB P

R2R1 A

B PR2R1

S2

S1

Sectional DrawingsReturn Detent

SR552- RN2In non-energized state

SR552- DN2(Solenoid S1 in released state

after it is energized)

Closed center Exhaust center Pressure center

SR552- CN2(Solenoids S1 and S2in non-energized state)

SR552- EN2(Solenoids S1 and S2in non-energized state)

SR552- PN2(Solenoids S1 and S2in non-energized state)

Valve

Manifold

Name Material

Materials of Major Parts

Main body

Main shaft

Lip seal

2-φ3.2 (Mounting holes)

35Approx. 300

27.5

12

12 6 6

P

R1

R2

AA

<View A>

B20

33

54

16

54

16

94.5123

21Manual overrideNon-lock type

5-Rc1/4

PR

2

2-φ3.2 spot facing φ6 depth 3(Mounting holes)

2

16

AB

2-M4×0.7 depth 15Mouth φ4.5 depth 11

1 1

4340

23

P

R1

R2

R1P

R2PR2

PR1A

B 30

29

2-φ4.5 (Mounting holes)

40

2949

2-M5×0.8

5-Rc1/4

84

7

21

30

38

4 4

Manual overrideNon-lock type

1015

182535

61Approx. 300

98100.5

3959

129

10

S2

S1

35Approx. 300

27.5

P

R1

R2

AB

10

10

27

27

27

27

80

160

51.5

212-Manual overridesNon-lock type

5-Rc1/4

2-PR

22

88

AB

2-φ3.2 (Mounting holes)

20

20R1P

R2PR2

PR1A

B 30

31

160103

29

2-φ4.5 (Mounting holes)

40

2949

2-M5×0.8

5-Rc1/4

84

7

98

21

30

38

4 4

S2

S1

2-Manual overridesNon-lock type 10

15182535

61Approx. 300

3959

10

S2

S1

35Approx. 300

27.5

P

R1

R2

AB

10

10

27

27

27

27

95

190

95

66.5

66.5

212-Manual overridesNon-lock type

5-Rc1/4

2-PR

22

88

AB

2-φ3.2 (Mounting holes)

20

20

2-Manual overridesNon-lock type

R1P

R2PR2

PR1A

B 30

46

190133

29

2-φ4.5 (Mounting holes)

40

2949

2-M5×0.85-Rc1/4

84

7

98

21

30

38

4 4

S2

S1

1015

182535

61Approx. 300

28.5

3959

10

■Direct type●SR552ーRN2 Voltage RK (return)

■Sub-plate typeーSP (return)●SR552ーRMM Voltage RK

ーSP (detent)●SR552ーDMM Voltage RK

ーSP (closed center)●SR552ーCMM Voltage RKーSP (exhaust center)●SR552ーEMM Voltage RKーSP (pressure center)●SR552ーPMM Voltage RK

●SR552ーDN2 Voltage RK (detent)

●SR552ーCN2 Voltage RK (closed center)●SR552ーEN2 Voltage RK (exhaust center)●SR552ーPN2 Voltage RK (pressure center)

5-port/2-poition and 3-position

Note) The valve will be delivered without the sub-plate mounted.

2-φ3.2 spot facing φ6 depth 3(Mounting holes)

2-φ3.2 spot facing φ6 depth 3(Mounting holes)

CAD/DATAis available.SR552/TSR552A(B)

Page 32: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR552SR552 SR2/RB

Small-size Solenoid Valve62VA

SR552SR2/RB SR552

Small-size Solenoid Valve 63VA

Unit: mm Unit: mm

1.65.6

128.6 (to valve upper surface)

2-φ4.5 (Mounting holes)

35

181846

LED indicator

36A

10

45

φ18

φ6 to φ8Cabtyre cable OD21

16 Width across flats

C

79

40.6

(10)

Pg9

SR552-RN2

SR552-RMM**-SP

SR552-DN2, SR552-DMM**-SP

SR552- (C, E, P) N2, SR552- (C, E, P) MM**-SP

130.5

136.5

175

205

Standard type: 300 mm

Order made:

1L: 1000 mm 3L: 3000 mm

Overall length to valve or

sub-base end face

Overall length to solenoid

end face on opposite side

(145.2)

(151.2)

(204.4)

(234.4)

Model number Symbol A

Dimensional TableC (lead wire length) Remarks

■Mounting plate (only return type) SZZ SR552-F

Option

Note) The valve will be delivered without the mounting plate mounted.

■Wiring method●DIN socket type●Q socket type

SR552-CMM*RK

SR552-DMM*RK

SR552-RMM*RK

2-Rc1/4 (for 1 station)

Seal plateMF552-MS

stn.1 stn.2 stn.3 stn.4

A

B

3 92810

34

224657

93

35Approx. 300

30.5

26

22

77

12

R1

R2

P

PR1

PR2

2×2-Rc1/8 (With 2 plugs: temporarily tightened)

2×3-Rc3/8 (With 3 plugs: temporarily tightened)

50.580

43

Manual overrideNon-lock type

1901019630

34.5 66.5

66.5

4-φ5.5 (Mounting holes)

LP 14

31 22 312221 20.520.5 21

14

S2S2

S1S1

R1PR2

SR552-CN2*RK

SR552-DN2*RK

SR552-RN2*RK

Seal plateMF552-ES

stn.1 stn.2 stn.3 stn.4

131530

66

35Approx. 300

4056

12

2×3-Rc3/8 (With 3 plugs: temporarily tightened)

10

10

51.5

43

80

80

Manual overrideNon-lock type

95

95

806330

66.5

66.5

4-φ5.5 (Mounting holes)

L

S2S2

S1S1

AAA

B B B

P 522 2222 2221 11.511.5 21

5

2Rc1/4 2

P

L

SymbolNo. of stations 2

56

84

4

100

128

6

144

172

8

188

216

10

232

260

Table of Dimensions of Manifold

Manifold■Mono-manifold

■Easy-manifold

P

L

SymbolNo. of stations 2

56

66

4

100

110

6

144

154

8

188

198

10

232

242

Table of Dimensions of Manifold

CAD/DATAis available.SR552/TSR552K

CAD/DATAis available.SR552/TSR552A(B)

Page 33: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR562SR562 SR2/RB

Small-size Solenoid Valve64VA

SR562SR2/RB SR562

Small-size Solenoid Valve 65VA

SR562-RN3

SR562-RMM

SR562-DN3

SR562-DMM

SR562-CN3

SR562-CMM

SR562-EN3

310

320(680)

510

540(900)

SR562-EMM

1373.0 m/s2

(1373.0 m/s2 in axial direction)1373.0 m/s2

(245.2 m/s2 in axial direction) 1373.0 m/s2 (490.3 m/s2 in axial direction)

SR562-PN3

SR562-PMM

Specifications for Valve Only

420

440(800)

AB

PR2 R1

AB

PR2 R1S1 S2

AB

S2S1 PR2 R1

AB

S2S1PR2 R1

AB

S2S1PR2 R1

Small-size lubrication-free solenoid valves having a valve width of 27 mm and effective sectional area of 40 mm² (2-position type)●Suitable for driving cylinders with bores from 80 to 125 mm●As standard devices for protection from power surge, the valves for AC are provided with varistors, and those for DC are provided with flywheel diodes.●The valves for AC power supply are applicable to 100 V AC to 120 V AC or 200 V AC to 240 V AC.●The valves can be wired by various methods, e.g. Q socket, P socket, DIN socket and lead wire methods, and the Q socket, P socket and DIN socket type valves are provided with lamps for easy confirmation as standard devices.

JIS symbol

Effective sectional area

Working fluid

Model number

Item

Directtype

P・A・B

R1・R2

Sub-platetype

P・A・B

R1・R2

Direct typeEasy-manifoldSub-plate typeMono-manifold

Model

Port size

Lubrication

Working pressure range

Proof test pressure

Working temperature range

Manual override

Installing direction

Recommended lubricantDirect typeEasy-manifoldSub-plate typeMono-manifold

Note 1)Response timeIn ON/OFF state

Note 2)Weight g

24 V DC, 12 V DC

100 V AC, 200 V AC

Vibration resistance/impact resistance

5-port

2-position 3-position

Return Detent 3-position closed center 3-position pressure center3-position exhaust center

Direct screw piping type: Rc3/8

35 mm240 mm2

Direct screw piping type: Rc3/8

Air

Unnecessary

25/30 ms or less

25/25 ms or less

15 ms or less

15 ms or less

25/25 ms or less

25/25 ms or less

0.17 to 0.7 MPa

1.05 MPa

+5 to +50℃ (ambient temperature and fluid temperature)

Pushing

Free

JIS K2213 Class 1 (additive-free turbine oil ISO VG32) or its equivalent

Note 1) Values at an air pressure of 0.5 MPa. The values were obtained at the opposite positions in the case of 2-position valves or in the valve neutral state in the case of 3-position valves.

Note 2) The parenthesized weight includes the weight of the sub-plate.

□(-)

12 V DC

140(1.7W)

8

Flywheel diode against surge

Red

Flywheel diode

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

For 12 V DC and 24 V DC For 100 V AC and 200 V AC

10.8 to 13.2

(12±10%)

Brown : +Black : -

100 V AC

100 or more

Lead wire type: 300 mm, P/Q socket type: 300 mm (standard)

50

55

24

60

49

19

Shading type

Varistor

Yellow

90 to 132

(100  %)

Yellow

24 V DC

75(1.8W)

4

21.6 to 26.4

(24±10%)

Red : +Black : -

RatingItem

Electrical Specifications

Note) The 1 and 3m lead wires (code; 1L and 3L, optional) of the P socket and Q socket type valves are in red and black.

+32-10

200 V AC

24

50

28

12

60

25

10

Green

180 to 264

(200  %)

White

+32-10

(+)

(-)

Lead wire 12 V DC: Brown24 V DC:  Red

Flywheel diode

Lead wire: Black

Short-circuit preventing diode

Solenoid

Lead wire 100 V AC: Yellow200 V AC: White

VaristorSolenoid

Lead wire 12 V DC: Brown24 V DC:  Red

Lead wire: Black

LED indicator(LED)

LED indicator, red

100 V AC: Yellow200 V AC: White

Lead wire

LED indicator(LED)

LED indicator color 100 V AC: Yellow200 V AC: Green

Diode

DIN□(+)

2

1

Type

Allowable circuit leakage current value

Insulation resistance MΩWiring method and lead wire length

Note) Lead wire color

Color of LED indicatorMeasures against surge(standard device)

Frequency Hz

Starting mA(r.m.s)

Exciting mA(r.m.s)

Lead wire type

Ele

ctric

circ

uit

Q socket type

P socket type

DIN socket type

Current value (when rated voltage is applied)

Working voltagerange

mA

V

Page 34: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR562SR562 SR2/RB

Small-size Solenoid Valve66VA

SR562SR2/RB SR562

Small-size Solenoid Valve 67VA

Common exhaust type

Rc1/2

MF562M

10 stations

2・4・6・8・10

P・R1・R2

A・B Rc3/8

MF562E

10 stations

2・4・6・8・10

Rc3/8 (valve side)

SR562-RN3

SR562-RMM

SR562-DN3

SR562-DMM

SR562-CN3

SR562-CMM

SR562-EN3

310

320(680)

510

540(900)

SR562-EMM

SR562-PN3

SR562-PMM

420

440(800)

MF562M-**A

MF562E-**S

1685

430

2615

700

3545

970

4475

1240

5405

1510

Name

Type

Model number

Max. number of stations

Standard number of stations

Exhaust type

Port size

Piping specification

Mono-manifold

Direct screw piping type

Manifold Specifications

Side piping

Easy-manifold

Direct screw piping type

Front piping

Model number

Item

5-port

2-position

Return Detent

3-position

Direct typeEasy-manifoldSub-plate typeMono-manifoldDirect typeEasy-manifoldSub-plate typeMono-manifold

3-position exhaust center 3-position pressure center

Model

Valve Weight

Note) The parenthesized weight includes the weight of the sub-plate.

3-position closed center

2 4 6 8 10

Mono-manifold

Easy-manifold

Manifold Weight Unit: g

Name

No. of stations

Note) Add the valve weight to the manifold weight.

Note)Weight g

Effective sectional area 40 mm²

0.1

00.1

1000 2000 30003500

0.20.30.40.50.60.7MPa

0.20.3

0.5

0.70.6

0.4

Effective sectional area 35 mm²

0.1

00.1

1000 2000 30003500

0.20.30.40.50.60.7MPa

0.20.30.40.5

0.70.6

Flow Characteristic Curves

How to read the chartWhen the flow rate is 1900 ℓ/min (ANR) at a supply pressure of 0.5 MPa, the valve outlet pressure is 0.4 MPa.

Valve outlet pressure

Valve outlet pressure

Flow rate ℓ/min(ANR) Flow rate ℓ/min(ANR)

SupplypressureMPa

SupplypressureMPa

Page 35: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR562SR562 SR2/RB

Small-size Solenoid Valve68VA

SR562SR2/RB SR562

Small-size Solenoid Valve 69VA

SR562- R N3 1 RK - 1L - FSeries

Mounting plateNo symbol: NoneF: With mounting plateNote) Only return type

SR562- R MM 1 RK - 1L - SPSeries

AB

PR2 R1

AB

PR2 R1S1 S2

AB

S2S1PR2 R1

AB

S2S1PR2 R1

AB

S2S1PR2 R1

■How to order●Model number of valve onlyDirect type (port size Rc3/8)Easy-manifold

Sub-plate type (port size Rc3/8)Mono-manifold

Note) The valve will be delivered without the sub-plate mounted.

Sub-plateNo symbol: NoneSP: With sub-plate

Lead wire lengthNo symbol: Standard (300 mm)1L: 1000 mm (order made)3L: 3000 mm (order made)Note) Only Q and P socket types.

All lead wires are in red and black.

Switching methodVoltage

Voltage (standard)Symbol

Voltage (option)

100 V AC   %(Lead wire color: yellow)

+32-10

200 V AC   %(Lead wire color: white)

+32-10

Other voltages

24 V DC ±10%(Lead wire color: + red, - black)◯◯

12 V DC ±10%(Lead wire color: + brown, - black)◯ ◯

1

2

8

6

9

Return

R

Detent

D

Closed center

C

Exhaust center

E

Pressure center

P

Switching methodSymbolWiring method (standard)

Wiring methodSymbol

Lead wire typeWith protective circuit

RK

Q socket typeWith indicating lamp/protective circuit

QW

P socket typeWith indicating lamp/protective circuit

PW

DIN socket typeWith indicating lamp/protective circuit

DW

Wiring method (option)

●Easy-manifold■How to order manifold

SR562-CMM1QW

SR562-RMM1QW

PR1

PR2

R1

R2

SR562-CN31QW

SR562-RN31QW

R1PR2

 ●Mono-manifold

P

MF562M- 04 A

SR562- R MM 1 QW - 1L

MF562-ES (For Easy-manifold)

●Model number of Easy-manifold

MF562E- 04 SSeries

No. of manifold stations

For Easy-manifold

Note) For details, see “How to order valve only”.

●Easy-manifold

SR562- R N3 1 QW - 1LSeries

Note) Easy-manifold valves will not come with manifold mounting gaskets and bolts. When adding a valve to a manifold, place an order for a gasket and bolt set at the same time.

Model numberPort size

SA2-M5

SA2-06

SA2-10

M5

G1/8

G3/8

■Related products/Silencers More compact installation is enabled.

■How to order manifold base●Model number of Mono-manifold

Series

■How to order manifold valve●Mono-manifold

■How to order seal plate SZZ

MF562-MS (For Mono-manifold)

Series For Mono-manifold

No. of manifold stationsNo. of stationsSymbol No. of stationsSymbol No. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Side piping (direct screw piping type)

Note) For details, see “How to order valve only”.

MF562-MGBS (For Mono-manifold)MF562-EGBS (For Easy-manifold)

■How to order gasket and bolt set SZZ

 ●A 6-station Mono-manifold type is shown as follows.  ●Manifold body   MF562M-06A  ●Valve block   SR562-RMM1QW   SR562-CMM1QW

Qty.1

33

Side piping (direct screw piping type)

No. of stationsSymbol No. of stationsSymbol No. of stationsSymbol

2 stations02

4 stations04

6 stations06

8 stations08

10 stations10

Qty.1

33

●A 6-station Easy-manifold type is shown as follows. ●Manifold body  MF562E-06S ●Valve block  SR562-RN21QW  SR562-CN21QW

Page 36: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR562SR562 SR2/RB

Small-size Solenoid Valve70VA

SR562SR2/RB SR562

Small-size Solenoid Valve 71VA

B

A

P

R2

R1

PR

Solenoid coverPlunger

Plunger spring

Piston

Main body

End cover

Plunger pinMold solenoid

Column

Main shaft

Lip seal

Flapper

Pilot valve body

Shading coil (only AC solenoid)

Manual override

B

A

PR1

S2

S1

PR2

R2

R1

P

R2

R1

PA

B

PR1

PR2

S2

S1

R2

R1

PA

B

PR1

PR2

S2

S1

R2

R1

PA

B

PR1

PR2

S2

S1

AB P

R2R1

AB P

R2R1

S2

S1

AB

S1

S2

PR2R1 A

B

S1

S2

PR2R1 A

B

S2

S1

PR2R1

Sectional DrawingsReturn Detent

SR562- RN3In non-energized state

SR562- DN3(Solenoid S1 in released state

after it is energized)

Closed center Exhaust center Pressure center

SR562-CN3(Solenoids S1 and S2in non-energized state)

SR562-EN3(Solenoids S1 and S2in non-energized state)

SR562-PN3(Solenoids S1 and S2in non-energized state)

Seal

Flapper

Plunger

Column

Sub-base

Mounting base

Main body

Block plate

Seal

Aluminum alloy (alumite)

Synthetic rubber (NBR)

Synthetic rubber (urethane)

Aluminum alloy (alumite)

Mild steel (nickel-plated)

Synthetic rubber (NBR)

Electromagnetic stainless steel

Aluminum alloy (alumite)

Mild steel (galvanized)

Valve

Manifold

Name Material

Materials of Major Parts

Main body

Main shaft

Lip seal

1 1

R1

P2

P28

17

PR

R1

A

BR2

P

49.750 A

24.7

35Approx. 300

40

328

25

37.2

60

19.7

4-φ4.4 (Mounting holes)

21

27Manual overrideNon-lock type

5-Rc3/82 2

10.5 10.5

60

19.7

107.7136.2 A

B

<View A>

PR1

PR2

P

R1

R2

27

21

36 55

46

13

41.566.5

A

B

Manual overrideNon-lock type

2-φ4.5 (Mounting holes)

38

28.5

108112140.5

Approx. 300 35 26

21

13

40 33

74

5429

50 94

7

5-Rc3/8

2-M5×0.8

2-PR

R1A

BR2

P 25

25

35Approx. 300

40

328

12.5

12.5

30

30

4-φ4.4

21

272-Manual overridesNon-lock type

5-Rc3/8

2 2

10.5 10.5

30

30

58

86.5

173

A

S2

S1

B PR1

PR2

P

R1

R2

S2

S1

27

21

36 55

46

13

41.566.5

A

B

2-Manual overridesNon-lock type

2-φ4.5 (Mounting holes)

38

28.5

108

32.5

116

28.5

173

Approx. 300 35 26

21

13

40 33

74

54

29

50 94

7

5-Rc3/8

2-M5×0.8

2-PR

R1A

BR2

P 25

25

35Approx. 300

40

328

12.5

12.5

30

30

4-φ4.4 (Mounting holes)

21

272-Manual overridesNon-lock type

2-φ4.4 spot facing φ8 depth 4(Mounting holes)

5-Rc3/8

2 2

10.5 10.5

30

30

76.4

104.9

209.8

A

S2

S1

B

PR1

PR2

P

R1

R2

S2

S1

27

21

36 55

46

13

41.566.5

A

B

2-Manual overridesNon-lock type

2-φ4.5 (Mounting holes)

38

28.5

108

50.9

152.8

28.5

209.8

Approx. 300 35 26

21

13

40 33

74

5429

50 94

75-Rc3/8

2-M5×0.8

■Direct type ■Sub-plate type5-port/2-poition and 3-position

Note) The valve will be delivered without the sub-plate mounted.

●SR562ーRN3 Voltage RK (return) ーSP (return)●SR562ーRMM Voltage RK

ーSP (detent)●SR562ーDMM Voltage RK●SR562ーDN3 Voltage RK (detent)

ーSP (closed center)●SR562ーCMM Voltage RKーSP (exhaust center)●SR562ーEMM Voltage RKーSP (pressure center)●SR562ーPMM Voltage RK

●SR562ーCN3 Voltage RK (closed center)●SR562ーEN3 Voltage RK (exhaust center)●SR562ーPN3 Voltage RK (pressure center)

2-M4×0.7 depth 16.7Mouth φ4.5 depth 12.7

2-φ4.4 spot facing φ8 depth 4(Mounting holes)

(Mounting holes)

2-φ4.4 spot facing φ8 depth 4(Mounting holes)

CAD/DATAis available.SR562/TSR562A(B)

Page 37: Pneumatic Solenoid Valves (Light Type) - taiyo-ltd.co.jp Valves... · Pneumatic Solenoid Valves (Light Type) ... Slowly push the tube all the way in. After fitting the tube, lightly

SR562SR562 SR2/RB

Small-size Solenoid Valve72VA

SR562SR2/RB SR562

Small-size Solenoid Valve 73VA

Unit: mm Unit: mm

7

143.2 (to valve upper surface)

2

B

20 20

2-φ4.5 (Mounting holes)

50

40

36A

LED indicator

10

47.5

C

φ18

φ6 to φ8 Cabtyre cable OD

21

16 Width across flats

Pg981.5

40.6

(10)

SR562-RN3

SR562-RMM**-SP

SR562-DN3, SR562-DMM**-SP

SR562- (C, E, P) RN3, SR562- (C, E, P) MM**-SP

143.7

148

188

224.8

(158.4)

(162.7)

(217.4)

(254.2)

Model number Symbol A

Dimensional TableC

■Mounting plate (only return type) SZZ SR562-F

Option

Note) The valve will be delivered without the mounting plate mounted.

■Wiring method●DIN socket type●Q socket type

Standard type: 300 mm

Order made:

1L: 1000 mm 3L: 3000 mm

Overall length to valve or

sub-base end face

Overall length to solenoid

end face on opposite side

(lead wire length) Remarks

SR562-CMM*RKSR562-DMM*RKSR562-RMM*RK

Rc3/8

Seal plateMF562-MS

A

B

323 9

1343

stn.1 stn.2 stn.3 stn.4

28576840

109

5466

22

R1

R2

P

PR1

PR2

88

12

35Approx. 300 2×2-Rc1/8

(With 2 plugs: temporarily tightened)

2×3-Rc1/2 (With 3 plugs: temporarily tightened)

49.7

5886.5

86.5

Manual overrideNon-lock type

104.9

104.976.4

76.4

11210632

38

4-φ6.5 (Mounting holes)

LP

S2S2

S1S1

14142835 3528

27 2721.521

SR562-CN3*RKSR562-DN3*RKSR562-RN3*RK Seal plate

MF562-ESstn.1 stn.2 stn.3 stn.4

165

203540

76

46

30

31

R1

R2

P64

14

35Approx. 300

2×3-Rc1/2 (With 3 plugs: temporarily tightened)

49.7

5886.5

86.5

Rc3/8

Manual overrideNon-lock type

104.9

104.976.4

76.4

92743230

4-φ6.5 (Mounting holes)

LP

S2

A A A

B B B

S2

S1S1

772828 2828

27 2714.521

2 2

12.5

12.5

70

98

126

154

182

210

238

266

294

322

70

84

126

140

182

198

238

252

294

308

Manifold■Mono-manifold

■Easy-manifold

P

L

SymbolNo. of stations 2 4 6 8 10

Table of Dimensions of Manifold

P

L

SymbolNo. of stations 2 4 6 8 10

Table of Dimensions of Manifold

CAD/DATAis available.SR562/TSR562K

CAD/DATAis available.SR562/TSR562A(B)