polysun projekat 2013
DESCRIPTION
Izrada projekata za termo solarne sisteme pomocu Polysyn programaTRANSCRIPT
Professional Report
1 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Project COMPACT2 1000L
Location of the system
Switzerland
Rapperswil (SG)
Longitude: 8.82°
Latitude: 47.23°
Elevation: 417 m
This report has been created by:
Vela Solaris AG
System overview (annual values)
Total fuel and/or electrical energy consumption of the system [Etot]
5,346.1 kWh
Total energy consumption [Quse] 28,998.8 kWh
System performance (Quse / Etot) 5.42
Comfort demand Energy demand covered
Professional Report
2 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Overview solar thermal energy (annual values)
Collector area 99 m²
Solar fraction total 85.7%
Total annual field yield 25,999.7 kWh
Collector field yield relating to gross area 262.7 kWh/m²/Year
Collector field yield relating to aperture area 464.3 kWh/m²/Year
Max. fuel savings 3,059 l: [Heating oil]
Max. energy savings 30,587.9 kWh
Max. reduction in CO₂ emissions 9,196.9 kg
Solar fraction: fraction of solar energy to system [SFn]
Horizon line
Meteorological data-Overview
Average outdoor temperature 10.1 °C
Global irradiation, annual sum 1,103.5 kWh/m²
Diffuse irradiation, annual sum 578 kWh/m²
Component overview (annual values)
Boiler 1 Oil boiler, small
Power kW 15
Total efficiency % 81.2
Energy from/to the system [Qaux] kWh 4,320.8
Fuel and electrical energy consumption [Eaux] kWh 5,323.3
Energy savings solar thermal kWh 30,587.9
CO₂ savings solar thermal kg 9,196.9
Fuel savings solar thermal l 3,059
Professional Report
3 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Collector Collector field NSC-58-30
Data Source SPF
Number of collectors 20
Number of arrays 1
Total gross area m² 98.98
Total aperture area m² 56
Total absorber area m² 48.02
Tilt angle (hor.=0°, vert.=90°) ° 45
Orientation (E=+90°, S=0°, W=-90°) ° 0
Collector field yield [Qsol] kWh 25,999.7
Irradiation onto collector area [Esol] kWh 69,225.2
Collector efficiency [Qsol / Esol] % 37.6
Direct irradiation after IAM kWh 37,145.5
Hot water demand Constant
Volume withdrawal/daily consumption l/d 1,470.2
Temperature setting °C 45
Energy demand [Qdem] kWh 21,389.4
Pool Pool Outdoor pool
Pool type Outdoor pool
Length m 10
Width m 7
Average depth m 1.7
Energy from/to the system [Quse] kWh 6,664.9
External heat exchanger Pool heat exchanger Plate heat exchanger, small
Transfer capacity W/K 5,000
Pump Solar pump Pump Eco, small
Circuit pressure drop bar 0.015
Flow rate l/h 450
Fuel and electrical energy consumption [Epar] kWh 10.9
Pump Pool pump Pump Eco, small
Circuit pressure drop bar 0.002
Flow rate l/h 450
Fuel and electrical energy consumption [Epar] kWh 5.9
Pump Solar pool pump Pump Eco, small
Circuit pressure drop bar 0.042
Flow rate l/h 450
Fuel and electrical energy consumption [Epar] kWh 5.9
Professional Report
4 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Storage tank Hot water tank 2700l combined tank with integrated water heater
Volume l 2,640
Height m 2.1
Material Stainless steel
Insulation Rigid PU foam
Thickness of insulation mm 100
Heat loss kWh 576.6
Connection losses kWh 195.2
Loop
Solar loop
Fluid mixture Propylene mixture
Fluid concentration % 40
Fluid domains volume l 154.1
Pressure on top of the circuit bar 4
Solar thermal energy to the system [Qsol] kWh
Professional Report
5 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Heat generator energy to the system (solar thermal energy not included) [Qaux] kWh
Solar fraction: fraction of solar energy to system [SFn] %
Total fuel and/or electrical energy consumption of the system [Etot] kWh
Professional Report
6 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Solar thermal energy to the system [Qsol]
kWh 26000 1228 1540 2255 2473 2941 3038 3254 3115 2382 1731 1124 919
Heat generator energy to the system (solar thermal energy not included) [Qaux]
kWh 4321 617 478 152 73 110 431 291 310 172 268 604 814
Heat generator fuel and electrical energy consumption [Eaux]
kWh 5323 755 588 189 95 139 531 362 385 217 334 739 990
Solar fraction: fraction of solar energy to system [SFn]
% 85.7 66.6 76.3 93.7 97.1 96.4 87.6 91.8 90.9 93.3 86.6 65 53
Total fuel and/or electrical energy consumption of the system [Etot]
kWh 5346 756 589 192 98 141 533 364 387 218 336 740 991
Irradiation onto collector area [Esol]
kWh 69225 3190 4038 6215 7081 7843 7643 8391 8170 6671 4775 2882 2325
Electrical energy consumption of pumps [Epar]
kWh 23 1 2 2 2 2 2 2 2 2 2 1 1
Heat loss to indoor room (including heat generator losses) [Qint]
kWh 2181 195 166 130 131 151 226 212 211 167 167 200 226
Heat loss to surroundings (without collector losses) [Qext]
kWh 173 9 14 18 25 21 12 13 11 18 15 11 7
Total energy consumption [Quse]
kWh 28999 1769 1921 2289 2424 2913 3366 3389 3288 2377 1961 1649 1652
Professional Report
7 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Collector Collector fieldDaily maximum temperature [ °C]
Pool PoolTemperature [ °C] - Daily average
Professional Report
8 / 8 V5.10.13.17087 / 02.12.2012 / 21:48:40
Vela Solaris AG, their distribution partners or SPF do not accept any liability for the correctness of the specifications and the results.
Energy flow diagram