portable instrument selection...

24
Portable Instrument Selection Guide

Upload: others

Post on 08-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Portable InstrumentSelection Guide

Page 2: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-33542

About MSA Instrument DivisionMSA's Instrument Division develops and manufactures portableand permanent gas-monitoring instruments for worker protectionand environmental monitoring, using sensing technologies fromcatalytic and electrochemical to infrared. We provide a family ofthermal imaging products to respond to a variety of needs,including increasing fire fighter safety by allowing workers to seethrough smoke. The Instrument Division also manufactures andsupplies medical instrumentation to protect healthcare employeesfrom hazards in the workplace and instruments for monitoringpatients. We have been designing and manufacturing gas detectionequipment for over 50 years and are dedicated to building thehighest-quality gas monitoring and medical instrumentation andsensors for our customers. The Instrument Division is a full-rangegas detection provider, engineering and producing our own sensors,pumps and other instrument components.

The Instrument Division meets the full ISO 9001 quality assurancerequirements of the International Organization for Standardization.This standard represents our commitment to continuousimprovement and quality from product design through productionto service at your site. In addition, many of our products have beenindependently tested and have earned global approvals.

The Instrument Division complex consists of a two-story, 54,000-square-foot administration building and laboratory, attached to aone-story, 152,000-square-foot manufacturing facility dedicated toinstrument and sensor assembly operations. Being a consolidatedmanufacturing facility allows us to communicate customer needsthroughout the production process and to provide rapid responsesto customer concerns.

MSA MissionStatementThat men and womenmay work in safetyand that they, theirfamilies and theircommunities may livein health throughoutthe world.

Our vision is to be theleading innovator andprovider of qualitysafety and instrumentproducts, services andspecialty chemicalsthat protect andimprove people'shealth, safety and theenvironment.

To provide satisfactionof customer needsthrough the efforts ofmotivated, involved,highly trainedemployees dedicatedto continuousimprovement inquality, service, cost,value, technology anddelivery.

Page 3: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Advanced TechnologyAdvanced technology in research anddevelopment as well as manufacturinghelps us to improve creativity, respondquickly to your changing needs, andcombine traditional value with constantproduct enhancement. Our innovative NewProduct Development process focuses ondesigning and developing instrumentsbased on customer input. By listening tothe voice of the customer throughout theproduct development process, we are ableto ensure MSA instruments meet userneeds.

Our products are tested with state-of-the-art computer equipment at everymanufacturing step, to ensure the highestquality possible. Although our facilities andequipment are new, we are still committedto the old-fashioned values of helping andsupporting our customers. MSA field salesrepresentatives and distributors arethoroughly trained in the use andapplication of our products. Ourapplications and inside sales departmentsare prepared to provide technical andcustomer service assistance. After the sale,we support our customers with the bestrepair and service organization in theindustry. Building on our experience, wecontinue to fulfill our leadership role in themedical, instrumentation and controlindustries by developing high-qualityproducts to solve our customers'monitoring needs.

Award-Winning Customer ServiceFinding the right instrument for your needs doesn't have to bedifficult if your first decision is to choose MSA. This selection guidewas designed to simplify your gas detection decision-makingprocess. It is just one example of MSA's commitment to providingsuperior customer service. With MSA, you also have access to themost dedicated and highly trained staff of portable detectorselection experts. We encourage you to use them. If you haveadditional questions at any point in the selection process or needassistance with an application not listed inthis guide, simply call our Customer ServiceTeam at 1-800-MSA-2222 (for InternationalCustomer Service call 1-412-967-3354). Inaddition to technical expertise, they canalso provide you with product data sheetsor the number of your local MSA distributor.

For informationon gas detectionin confinedspaces, consultMSA Bulletin5555-57, Closing InOn ConfinedSpaces: A PrimerOn Hazards andEquipment.

Cross-Sensitivity:Since sensoroutput is driven bychemical reactions,there arecircumstanceswhere gases otherthan those beingmonitored willcause a reading onthe instrumentdisplay. This isknown as "cross-sensitivity". Usersshould be aware ofthis potentialwhen selecting aninstrument. Formore informationconsult theinstrumenttechnical manualor MSA's CustomerService Center.

Purpose of GuideThis guide is designed to quickly and easily help you identify theportable gas detection solution to your specific needs. To assist inthis process, it identifies some of the atmospheric hazards that arecommonly found in various industries.

▲WARNINGThe information in this guide is not intended to be all-inclusive inscope or content and is not to be used as a substitute for acomprehensive hazards assessment. Contact MSA for moredetailed information. Failure to follow this warning can result inserious personal injury or death.

3Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

!

Page 4: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-33544

Do you know whichgas(es) you need to

detect?

Use the table on thefollowing page to

determine the gas(es)commonly found in your

industry.

Use the “Gas MonitoringCategories” table on the

following page todetermine your gas

category. Turn to theappropriate section for a

list of instruments in yourcategory.

Are you monitoring asingle gas?

Is it one of the following:O2, CO, H2S, Cl2, ClO2, or a

combustible gas?

See the “Single-GasInstruments” section of

the table on page 9.

How to Use This Guide

YES YES

NO

NO

NO

YES

Consult the Product Sectionbeginning on page 10 for

more information on aspecific instrument.

ContentsHazard Detection PageCombustible Gas Detection..................................6Toxic Gas & Oxygen Detection.............................7VOC Detection...........................................................8Dust & Particulate Sampling ...............................8

Product Section PageMultigas Instruments ..........................................10Single-Gas Instruments .......................................12PIDs, Detector Tubes & Sampling Pumps........14Calibration ................................................................16

Reference PageInstruments & Industries Table..........................18

Page 5: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

5Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

GasMonitoringCategories

COMBUSTIBLE GASESAcetone (C3H6O)Benzene (C6H6)Butane (C4H10)Ethylene (C2H4)Heptane (C7H16)Hydrogen (H2)Isobutane (C4H10)Methane (CH4)Pentane (C5H12)Toluene (C7H8)

TOXIC GASESAmmonia (NH3)Carbon Dioxide (CO2)Carbon Monoxide (CO)Chlorine (Cl2)Chlorine Dioxide (ClO2)Hydrogen Sulfide (H2S)Nitric Oxide (NO)Nitrogen Dioxide (NO2)Phosphine (PH3)Sulfur Dioxide (SO2)

Indu

stry

Gases/Hazards& Industries

Com

bust

ible

Gas

es

O2 D

efici

ency

/Enr

ichm

ent

Amm

onia

Carb

on D

ioxi

de

Carb

on M

onox

ide

Chlo

rine

Chlo

rine

Diox

ide

Form

alde

hyde

Hydr

ogen

Sulfi

de

Nitri

c Oxi

de

Nitro

gen

Diox

ide

Ozon

e

Phos

phin

e

Sulfu

r Dio

xide

Dust

& P

artic

ulat

e

VOCs

Agriculture

Asbestos Abatement

Aviation

Chemical

Construction

Fire Service

Food & Beverage Processing

Foundries

HazMat

Heavy Manufacturing

Iron & Steel

Mining

Nuclear

Oil & Gas/Petrochemical

Paper & Pulp

Pharmaceutical

Sand Blasting

Sanding & Grinding

Semiconductor

Shipyard/Marine

Spray Painting

Utilities

Water & Wastewater Treatment

Welding

••••••••••••

•••

••

•••••••

••••

•••

•••

•••

•••

••

••••

•••••••

•••••

••••••

••

•••

••

••

••

••

••

• •

••

••

••

•••

••

•••••

••

Gases/Hazards

Page 6: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

1

1

••

1

1

•••

Uniq

ue to

Orio

nFe

atur

esSe

nsor

Opt

ions

and

FiveS

tar

Combustible Combustible Gases,Combustible Gases Gases & O2 O2 & Toxic Gases

CombustibleGas DetectionInstrumentsFeatures

1

1

1

1

2

2

• •

••

5

11

•••••••••

••

•••••

••••

5

9

•••

•••

• •

•••

•••

5

7

•••

• •

••••••

4

4

•••

• •

••

And up to three of the following:

And up to twoof the following:

PORT

ABLE

INST

RUM

ENTS

Tita

n™ C

ombu

stib

leGa

s Det

ecto

r

Gasc

ope®

Com

bust

ible

Gas I

ndica

tor

Tank

scop

e® C

ombu

stib

leGa

s Ind

icato

r

Expl

osim

eter

®Co

mbu

stib

le G

as In

dica

tor

Micr

oGar

Porta

ble

Alar

m

FiveS

tar®

Ala

rm

Pass

port®

Per

sona

l Ala

rm

Wat

chm

an®

Mul

tigas

Mon

itor

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

* For sensor availability, call MSA’s Customer Service Center at 1-800-MSA-2222.

4

4

••

••

••

Number of Gases Detected

Number of Sensors Available

Combustible Gases

High-Range Methane Detection

Oxygen

Ammonia

Carbon Monoxide

Chlorine

Chlorine Dioxide

Hydrogen Sulfide

Nitric Oxide

Nitrogen Dioxide

Phosphine

Sulfur Dioxide

Analog Display

Digital Display

Alarms (Audible & Visual)

Vibrating Alarm

Hand Held

Pocket Sized

Hands-Free Operation

Memory Storage/Datalogging & Data Downloading

Datatagging

High RF Protection

Multilingual Display

Remote Alarm

Lockalarm™ Circuit

Autocalibration

Smart Sensors

Pressure Compensated O2

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-33546

Page 7: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

7Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Number of Gases Detected

Number of Sensors Available

Toxic—IDLH

Toxic—Non-IDLH

Volatile Organic Compounds (VOCs)

Combustible Gases

Oxygen

Ammonia

Carbon Dioxide

Carbon Monoxide

Chlorine

Chlorine Dioxide

Hydrogen Sulfide

Nitric Oxide

Nitrogen Dioxide

Phosphine

Sulfur Dioxide

Digital Display

Alarms (Audible & Visual)

Vibrating Alarm

Hand Held

Pocket Sized

Hands-Free Operation

Memory Storage/Datalogging& Data Downloading

Datatagging

High RF Protection

Multilingual Display

Remote Alarm

Lockalarm™ Circuit

Patented Button™ Sensors

Autocalibration

Smart Sensors

Pressure Compensated O2Uniq

ueto

Orio

nFe

atur

esSe

nsor

Opt

ions

and

FiveS

tar

1

5

••

••••

•••

1

3

••

••

Toxic Gas &OxygenDetectionInstrumentsFeatures

1

3

••

•••

****

•••

•••

••

****

••

•••

••

5

11

••

•••••••• ••

•••••

•••••

4

4

••

••

••

•••••

5

9

••

••

•••

• ••

• ••

•••

5

7

••

•••

•••

••••••

4

4

••

••

••

•••

And any three of the following:

And up to two of the following:

PORT

ABLE

INST

RUM

ENTS

Resp

onde

r® A

larm

s

PULS

AR™

Sing

le-G

asDe

tect

or

PULS

AR+

Sing

le-G

asDe

tect

or

Dete

ctor

Tube

s

Pass

port®

PID

II Or

gani

cVa

por M

onito

r

Pass

port®

VOC

2000

M

onito

r

FiveS

tar®

Ala

rm

Pass

port®

Per

sona

l Ala

rm

Wat

chm

an®

Mul

tigas

Mon

itor

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

1

*

•••

••••••

•••

* Detector tubes are available for the detection of over 170 gases. Contact MSA’s Customer Service Center for a complete list.** Instrument is pre-programmed for direct readings of 69 VOCs. Over 400 VOCs are potentially detectable. For a complete list, contact MSA’s Customer Service Center.

Toxic Gases Toxic Gases Toxic Gases Combustible Gases,& VOCs VOCs & O2 O2 & Toxic Gases

Page 8: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-33548

Number of Gases Detected

Toxic—IDLH

Toxic—Non-IDLH

Oxygen

Chlorine

Chlorine Dioxide

Hydrogen Sulfide

Phosphine

Acetone

Benzene

Chlorobenzene

Cyclohexane

Heptane

Hexane

Methyl Isobutyl Ketone (MIBK)

Methyl Tetrabutyl Ether (MTBE)

Octane

Propylene

Toulene

Trichloroethane

Many Other VOCs *

Digital Display

Alarms (Audible & Visual)

Hand Held

Memory Storage/Datalogging & Data Downloading

Feat

ures

Gase

s Det

ecte

d

VOCs & VOCs, Toxic Toxic Gases Gases & O2

*••

•••••••••••••••••••••

VOCDetectionInstrumentsFeatures

*••••••••••••••••••••••••

PORT

ABLE

INST

RUM

ENTS

Pass

port®

PID

II Or

gani

cVa

por M

onito

r

Pass

port®

VOC

2000

Orga

nic V

apor

&

Oxyg

en M

onito

r

* Instrument is pre-programmed for direct readings of 69 VOCs. Over 400 VOCsare potentially detectable. For a complete list, contact MSA’s Customer ServiceCenter.

Note: Detector tubes and sorbent tubes can also be used to identify specific VOCs.

Internal Secondary Calibration Standard

Timer

Coal Dust Sampling

Silica General Purpose

AsbestosSam

plin

gFe

atur

esCa

sset

tes

•••••

Dust &ParticulateSamplingPumpsFeatures

•••

PORT

ABLE

INST

RUM

ENTS

Esco

rtEL

Sam

plin

g Pu

mp

Esco

rt® LC

Sa

mpl

ing

Pum

p

Page 9: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

9Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Combustible Gases

O2 (Deficiency/Enrichment)

Ammonia—NH3

Carbon Dioxide—CO2

Carbon Monoxide—CO

Chlorine—Cl2

Chlorine Dioxide—ClO2

Formaldehyde—CH2O

Hydrogen Sulfide—H2S

Nitric Oxide—NO

Nitrogen Dioxide—NO2

Ozone

Phosphine—PH3

Sulfur Dioxide—SO2

Volatile Organic Compounds

Gases &PortableInstruments

•••

•••

• ••

•••••••

••••• • •

••••••

•••

••

••••••

•••

••

•••

••

•••

••

* For sensor availability, call MSA’s Customer Service Center at 1-800-MSA-2222.

Single-Gas Multigas Calibration GasInstruments Instruments & Accessories

PORT

ABLE

INST

RUM

ENTS

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

rGa

scop

e® C

ombu

stib

leGa

s Ind

icato

r

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r®Al

arm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Perso

nal A

larm

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Wat

chm

an®

Mul

tigas

Mon

itor

Dete

ctor

Tube

s

Esco

rtEL

F® Sa

mpl

ing

Pum

p

Esco

rt® LC

Sam

plin

g Pu

mp

Pum

pCal

ibra

tion

Chec

k Gas

Calib

ratio

n Ch

eck K

its

TIM®

Syst

em

PersonalSampling

Pumps

Gase

s

•••

•••

•••

••

••

••

••

•••

••

•••

••••

••••

••

•••

Inst

rum

ent

MSA PortableInstrumentApprovals

MET

MSH

A

PADE

P

UL Cana

da

Euro

ope

(CE)

Aust

ralia

ETL

Escort ELF® Sampling Pump

Escort® LC Sampling Pump

Explosimeter® Combustible Gas Indicator

FiveStar® Alarm

Gascope® Combustible Gas Indicator

MicroGard® Portable Alarms

Orion® Multigas Detector

Orion G Multigas & Leak Detector

Passport® Personal Alarm

Passport® PID II Organic Vapor Monitor

PULSAR™ Single-Gas Detector

PULSAR+ Single-Gas Detector

Responder® Alarms

Tankscope® Combustible Gas Indicator

Titan™ Combustible Gas Detector

VOC 2000 Organic Vapor & O2 Monitor

Watchman® Multigas Monitor

••

•••

•••

••

*

••

••

••

ATEX

ATEXATEX

ATEX

ATEX

cULcUL

cUL

cUL*

* Approvals pending

Page 10: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

10

FiveStar® Alarm

[Rugged, reliable 5-gasdetection at your fingertips]

• Sensors available: O2, CO,Cl2, ClO2, H2S, NO, NO2,PH3, SO2, NH3 andcombustible gas

• Autocalibration• “Smart sensors”• Pressure-compensated

oxygen• High levels of RFI protection• Multilingual display• Weather-resistant• World’s leading poison-

tolerant combustible sensor• Battery gas gauge• Fast charger option• Up to 20 hours of use with

optional NiMH battery• 2-year sensor warranty for

most sensors

(For more complete information,see Bulletin 0816-06.)

Features

MSA's multigas detectorscome equipped with thefollowing features:

• Audible & visual alarms• Push-button calibration*• Peak readings• STEL & TWA• Lockalarm™ feature

(instrument automaticallylocks in the alarm modewhen the gas exposure levelexceeds 100% LEL)

• Continuous pumpedoperation (as an add-on forsome instruments)

• Rechargeable or alkaline battery pack option**

* except MicroGard® Alarm** except Watchman® Multigas Monitor

Multigas InstrumentsMultigas detectors are used primarily to monitor immediatehazards. They can be used for both continuous and intermittentgas detection.

MSA offers a full line of multigas instrument accessories,including batteries, chargers, pumps, sample lines and probes.

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Orion® MultigasDetector

[ The standard for reliability, easeof use and durability ]

• Detects up to 4 gases including O2, CO, H2S,and combustible gas

• Simple, intuitive 2-button operation

• Rugged construction• Large display with great

contrast• Internal pump• 16-hr run time in pumped

mode• NiMH or alkaline batteries• TIM System-compatible• IP54-rated• Sensors are easy to change(For more complete information,see Data Sheet 08-16-27.)

Page 11: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

11Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Watchman® MultigasMonitor

[ Designed to withstand themost demanding environments ]

• Monitors up to 4 gases including O2, CO, H2S, NO,NO2, SO2 and combustible gas

• Extremely durable• High RFI protection• 14-hour battery run time as

standard feature• Remote alarm

(For more complete information,see Data Sheet 08-02-39.)

Passport® PersonalAlarm[ Known world-wide for itsreliability and long service life ]

• Detects up to five gases including NH3, O2, CO, Cl2,H2S, NO, NO2, SO2 and combustible gas

• Remote alarm• Over 50,000 sold

(For more complete information,see Data Sheet 08-00-39.)

Orion® G Multigas& Leak Detector[ Detects gas leaks atappliances, flues andunderground pipes ]

• Multi-functional flexibility;indoor, outdoor andunderground

• Measures low-level leaks, 0-100% LEL, 0-100% byvolume, O2, CO and H2S (anycombination)

• Fast response, intrinsicallysafe leak sensor

• Ergonomic design that fitssnugly in hand

• Long-life NiMH or alkalinebatteries (interchangeable)

• Large display, with greatcontrast for quick, easyreadings

• Bar-hole probe filter trapdesigned to keep out waterand dust

(For more complete information,see Data Sheet 08-04-27-MC.)MicroGard® PortableAlarms

[ Economical 2-gas instrumentfor detecting oxygendeficiency and combustiblegas ]

• Detects O2 and combustible gas

• Pocket-sized• Economical• Lightweight

Page 12: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335412

Single-Gas InstrumentsSingle gas detectors are an economical way to monitor a specificsingle gas. MSA toxic gas indicators can be used for continuousmonitoring of CO, O2, or H2S. MSA combustible gas indicatorscan be used to measure methane, pentane, and many othercombustible gases.

Responder® Series

[ Compact, lightweight andeasy-to-operate single gasdetector with display ]

• Units available to detect O2,CO, H2S, Cl2 or ClO2

• Digital display• Pocket-sized• Audible, visual & vibrating

alarms (audible & visualalarms for MiniOx)

• Adjustable alarm levels• Peak readings• MiniOx Remote Responder

available for remotesampling of confined spaces

(For more complete information,see Bulletin 0802-16.)

PULSAR™ Single-GasDetector[Everything you want in aportable, maintenance-freeinstrument]

• Units detect CO, O2 or H2S• Maintenance-free, two-year

service life• No need to calibrate

instrument• Long-life lithium battery,

33% longer than competition

• Large, easy-to-read, numericend-of-service-life indicator,characters 4x larger than other displays

• Distinctive audio, visual andoptional vibrating alarms

• Durable, passes 6-ft.drop test

• Water and dust resistant,passes IP54 rating

• MSA’s patented Button™ Sensors

(For more complete information,see Data Sheet 0802-18.)

PULSAR+ Single-GasDetector[Industry-leading performancewith a gas-concentrationdisplay]

• Units available to detect O2,CO or H2S

• MSA’s patented Button™ Sensors

• Autocalibration with no accessories needed

• Long-life, replaceable lithium battery

• Excellent water and dustresistance, IP54 rating

• Piercing audio, ultra-brightvisual and optional vibratingalarms

• Lifetime warranty

Page 13: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

13Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Explosimeter®Combustible GasIndicator[ Combustible detection withsimple analog operation ]

• Detects and measuresconcentrations ofcombustible gases or vaporsin the air

• Can be used in theimmediate environment orfor remote sampling ofconfined spaces

• Easy-to-read analog display• Hand-held

(For more complete information,see Data Sheet 08-00-03.)

Tankscope®Combustible GasIndicator, Model 62T

[ For combustible gasdetection in inertedenvironments ]

• Specifically designed todetect combustible gaslevels in inerted shipboardoil holds

• Easy-to-read analog display• Very simple to use

(For more complete information,see Bulletin 0804-29-MC.)

Gascope®Combustible GasIndicator[ Dual-range combustible gasdetector ]

• Detects, measures, andpinpoints leaks ofcombustible gases andvapors

• Wide detection rangeallows for readings abovethe UEL

• Dual-detection range givesreadings in both % LEL and% by volume

• Easy-to-read analog display

(For more complete information,see Data Sheet 08-01-04.)

Titan™ CombustibleGas Detector[ High-performancecombustible gas detector withinnovative design and smallsize ]

• Detects and measurescombustible gas or vaporconcentrations

• Reads % LEL or % by volume• Simple, intuitive, one-button

operation• Large, easy-to-read display• Audible and visual alarm

with optional vibratingalarm

• Optional NiMH battery pack• Full battery charge with

MSA Fast Charger• Strong construction, with

excellent resistance towater and dustpenetration–IP54 rating

• Features MSA Series 20LSensor for expanded sensorlife

• Sensor is very easy toreplace

(For more complete information,see Bulletin 0802-20.)

Page 14: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335414

Detector Tubes

• Available for the detection of over 170 gases and vapors

The MSA Kwik-Ref™ DetectorTube CD-ROM Database listsall tubes available, along withfacts on chemical reaction andcolor changes, interferences,cross-sensitivities, and more.

(For more complete information,see Data Sheet 08-00-02-MC.)

PIDs, Detector Tubes &Sampling PumpsPhotoionization detectors (PIDs) are primarily used for detectingVOCs or very low concentrations of toxic gases. They are suitablefor immediate as well as chronic hazard monitoring. Detectortubes are an inexpensive way to perform a quick atmosphericcheck. Sampling pumps and cassettes are particularly suited formonitoring chronic hazards related to dust, fibers andparticulate.

Passport® PID IIOrganic VaporMonitor

[ A convenient, portableinstrument for detecting lowconcentrations of VOCs ]

• Compact design• Built-in pump• 0.1 – 10,000 ppm operating

range• Graphic & numeric displays• Datalogging & data

downloading• Easy to use & operate

(For more complete information,see Data Sheet 08-01-39.)

Passport® VOC 2000Organic Vapor andOxygen Monitor

[ Detects VOCs and oxygenlevels in a variety ofmonitoring applications ]

• Integrated O2 sensor• Compact design• Built-in pump• 0.1 – 10,000 ppm operating

range• Graphic & numeric displays• Datalogging & data

downloading• Easy to use & operate

(For more complete information,see Bulletin 0816-19-MC.)

Detector Tube Pumps

MSA offers both manual andautomatic detector tubepumps.

Page 15: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

15Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Escort® LC SamplingPump

[ A durable and economicalsampling pump providingregulated flow for many typesof sample collection media ]

• For personal and areasampling

• Compact & lightweight• Timer• Engineered for use in

“hostile” environments• Can be used with many

types of sample collectionmedia, including filter discs,charcoal tubes & othersorbent tubes.

(For more complete information,see Data Sheet 08-04-01.)

Sampling PumpAccessories

MSA sampling pumpaccessories include filtermedia, a cyclone assembly,preweighed filter cassettes,filter holder assemblies,impingers, the Gemini® Twin-Port Sampler, sorbent tubes,and calibrators.

(For more complete information,see Data Sheet 08-09-01.)

Escort ELF® SamplingPump

[ State-of-the-art electroniclaminar flow sensor providesconstant flow control in acompact, lightweight samplingpump ]

• State-of-the-art electroniclaminar flow sensor

• For personal and areasampling

• Compact & lightweight• Timer• Engineered for use in

“hostile” environments• Can be used with many

types of sample collectionmedia, including filter discs,charcoal tubes & othersorbent tubes.

(For more complete information,see Bulletin 0810-38-MC.)

Page 16: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335416

Calibration Accessories

Regulators

MSA offers a complete line ofregulators to accurately matchgas delivery to instrument flowrequirements. Three types ofregulators are available: fixedflow, matched flow anddemand.

Computerized Calibrationand Record Keeping with The TIM® SystemCalibration checks help to ensure the accuracy of gas monitoringand detection equipment. To assist you in this essential process,MSA offers the TIM Total Instrument Manager System and acomplete line of calibration accessories.

The MSA TIM System is a computer-controlled, automaticcalibration system. The TIM System’s data software includes auser-friendly archive—with both view and print capability—of allcalibrations of all instruments that were bump-tested orcalibrated on the TIM System. The TIM System is compatible withthe MSA Orion Multigas Detector, FiveStar Alarm, PassportPersonal Alarm, Gasport Gas Detector and Watchman MultigasMonitor.

Additional features include:

• Can be configured to calibrate four instrumentssimultaneously & provide immediate results

• Auto-recognition of instrument sensor configuration• Computer-based test program• Calibration to factory recommendations• Permanent calibration history records• Record of sensor response after calibration• Print capability for all instrument test records• Immediate computer-generated test receipt

(For more complete information, see Bulletin 0818-02.)

Page 17: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

17Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Calibration Kits

A complete line of calibrationkits is available for instrumentcalibration. Kits include allnecessary tubing andadapters, regulators andcalibration instructions.Calibration kits are housed in aheavy-duty plastic case,complete with a molded insertto house all accessories,regulators and calibrationcylinders.

Test Kits

Squirt® Gas Bump Test Kits areavailable for testing theoperation of an instrumentbefore each use. Kits areequipped with all necessarytubing, adapters and squirtgas cylinder in a handycarrying case.

Calibration Cylinders

MSA offers a complete line ofcalibration gas to support allof your instrument calibrationneeds. Calibration gas issupplied in six cylinder sizes,ranging from 11-liter squirt gasfor bump testing to 552-litercylinders for large-volumeusers.

Each cylinder is shipped withan individual copy of an MSDSand a Certificate of Analysis,ensuring an exact calibrationfor both MSA and non-MSAinstruments. For yourconvenience, reactive gaseshave an expiration date listedon each cylinder.

MSA calibration cylinders arerecyclable. Contact theCustomer Service Center foradditional details.

Page 18: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335418

Instruments& Industries

Agric

ultu

reAs

best

osAb

atem

ent

Avia

tion

Chem

ical

Cons

truc

tion

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

rGa

scop

e® C

ombu

stib

leGa

s Ind

icato

r

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

& Le

ak

Dete

ctor

Pass

port®

Perso

nal A

larm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

Application/Task Gas/Hazard

chillers NH3

silos/confined space CO2

forklift operation CO

fumigant H2S

silos/confined space NO

silos/confined space NO2

silos/confined space O2Deficiency/Enrichment

insecticide for fumigation PH3

asbestos fibers & lead dust Dust &Particulate

engine repair & maintenance CO

CombustibleGases

confined space O2Deficiency/Enrichment

jet fuel vapors, solvents VOCs

NH3

general leak detection CO

Cl2

drying, milling & Dust &blending operations Particulate

general leak detection H2S

NO

NO2

confined space, liquidnitrogen carriers/storage, O2reactor work, tank maintenance,inspection tunnels Deficiency/Enrichment

SO2

organic synthesis operations,liquid-solid separation, cleaningagents VOCs

vehicle emissions (dieselexhaust), generators,digging operations,trenching CO

trenching Combustibleunderground construction Gases

underground construction,excavation, demolition, Dust &oil mist sampling Particulate

digging operationsunderground construction H2S

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

• • • •• •

• • • • • • • • •• • • • • • • • • • •

• • • •• • • • •

• • • • • • • • • •• • • • •

• • • • • • • • •• • • • • • • • •

• • • • • • • • • •• • • •

• • • • •• • • • • • • • •

• • • • ••

• • • • • • • • •• • • •• • • • •

• • • • • • • • • •

• • • • •• • • •

• • • • • • • • •

• • • • • • •

• • • • • • • • • • •

Page 19: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

19Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Foun

drie

sCo

nstr

uctio

nFir

e Se

rvice

Food

& B

ever

age

Proc

essin

gInstruments& Industries

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

rGa

scop

e® C

ombu

stib

leGa

s Ind

icato

r

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Perso

nal A

larm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

Application/Task Gas/Hazard

diesel exhaust NO

diesel exhaust NO2

confined spaces, trenching, O2underground construction Deficiency/Enrichment

VOCs

confined space entry (rescue) CO2

overhaul, homecalls (furnace leaks),trenching CO

underground construction, Combustibletrenching Gases

Dust &Particulate

H2S

confined space entry (rescue), O2underground construction Deficiency/Enrichment

refrigeration facilities& cold storage NH3

breweries & wineries,carbonated beverage bottling,fermentation tanks,refrigeration facilities, bakingfacilities CO2

forklifts CO

H2S

confined space, O2 packaging or gassing foodsDeficiency/Enrichment

PH3

furnace operation,coremaking,metalpreparation & pouring CO

Combustible Gases

mold preparation,casting cleaning,furnace changing, Dust &cleaning & finishing process Particulate

coremaking H2S

NO

NO2

SO2

confined space O2

• • • •• • • •

• • • • • • • • •• • • •

• • • •• • • • • • • • • •

• • • • • • • • • ••

• • • • • • • • • • • •• • • • • • • • • •

• • • • •

• •

• • • • • • • • •• • • • • •• • • • • • • • • •

• • • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • • •• • • •• • • • •• • • • •

• • • • • • •

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

Page 20: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335420

Instruments& Industries

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

r

Gasc

ope®

Com

bust

ible

Gas I

ndica

tor

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Perso

nal A

larm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

HazM

atHe

avy

Man

u-fa

ctur

ing

Iron

& St

eel

Min

ing

Application/Task Gas/HazardHazMat response NH3

CO

Cl2

Combustible Gases

Formaldehyde

H2S

PH3

SO2

VOCs

confined space,underground construction, O2 trenching Deficiency/Enrichment

manufacturing process emissions,forklift & crane operations various gases

blast furnace operation & maintenance, coke oven & converter operation,furnace & gas pipeline leaks,coking operations CO

Combustible Gases

handling of coal & ore,coke manufacturing, Dust & furnace maintenance Particulate

coking operations H2S

welding NO

welding NO2

confined space O2 Deficiency/Enrichment

coking operations SO2

motor maintenance & cleaning, coke oven emissions VOCs

confined space “Black Damp”(O2 Deficiency)

mechanized coal cutting “Fire Damp”(Combustible

Gases)

mining process “Stink Damp”(H2S)

result of combustion (fire),diesel-powered machinery, “White Damp”confined space, blasting (CO)

CO2

• • • • • •• • • • • • • • •

• • • • • • •• • • • • • • • • •

• • •• • • • • • • • • • •

• • • • •• • • • •

• • • •• • • • • • • • •

• • • •

• • • • • • • • •

• • • • • • • • •

•• • • • • • • • • • •

• • • •• • • • •

• • • • • • • • • •• • • • • •

• • •

• • • • • • •

• • • •

• • • • • • •

• • • • • • •

• •

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

Page 21: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

21Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Instruments& Industries

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

r

Gasc

ope®

Com

bust

ible

Gas I

ndica

tor

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Perso

nal A

larm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

Application/Task Gas/Hazard

drilling, blasting & cutting,coal transportation, Dust & mechanized mining Particulate

diesel exhaust NO

diesel-powered machinery,blasting NO2

confined space O2 Deficiency/Enrichment

petroleum refining NH3

incomplete combustion,conversion, coking,general processing,leak detection CO

conversion processes,isomerization, leak detection,catalytic reforming, Combustible treatment processes Gases

heavy hydrocarbon Dust & processing (coking) Particulate

refining process,general leak detection,treatment processes,crude separation,drilling rigs H2S

confined space, tank-cleaningoperations, enclosed buildings orstructures O2

Deficiency/Enrichment

refining process,process stream sample collection,general plant operations VOCs

paper production (bleaching) Cl2

paper production (bleaching) ClO2

wood preparation,pulping, Dust & wood dust sampling Particulate

chemical pulping,Kraft pulping H2S

chemical pulping,Kraft pulping SO2

paper production (coating & drying) VOCs

manufacturing NH3

manufacturing Cl2

manufacturing Combustible Gases

drying, milling & Dust & blending operations Particulate

manufacturing Formaldehyde

Min

ing

Nucle

arOi

l & G

as/P

etro

chem

ical

Pape

r & P

ulp

Phar

mac

eutic

al

•• • •• • • •

• • • • • • • • •

• • • • • •

• • • • • • • • •

• • • • • • • • •

• • • • • • • • • • • •

• • • • • • • • • •

• • • •

• • • • • • •• • •

•• • • • • • • • • • •

• • • •• • • •

• • • • • •• • • • •

• • • • • • • • ••

• • •

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

Page 22: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-335422

Instruments& Industries

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

r

Gasc

ope®

Com

bust

ible

Gas I

ndica

tor

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Pers

onal

Ala

rm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

Application/Task Gas/Hazard

manufacturing H2S

chemical synthesis, tank-cleaning,enclosed buildings O2or structures Deficiency/Enrichment

manufacturing SO2

organic synthesis,liquid-solid separation,compounding, granulating & tablet-coating operations,drying & packaging VOCs

general operations Dust & Particulate

grinding operations,manufacture of paints & glass, routine maintenance activities, Dust & construction, demolition Particulate

manufacturing NH3

manufacturing Cl2

manufacturing NO

manufacturing NO2

as doping agent in manufacturing, diffusion and ion implementation,chemical vapor deposition PH3

lithography, etching,oxidation, metallization,assembly & testing VOCs

confined space CO2

combustion CO

oil transshipment(combustible gas sampling in an Combustible inert environment) Gases

construction & repair(abrasive blasting operations,cutting & grinding, Dust & burning, heating) Particulate

tank emissions H2S

confined space,storage tanks, O2 cargo holds Deficiency/Enrichment

general operations Dust & Particulate

use of water-based paint Formaldehyde

use of solvent-based paint VOCs

Phar

mac

eutic

alSa

ndBl

astin

gSa

ndin

g &

Grin

ding

Ship

yard

/Mar

ine

Sem

icond

ucto

rSp

ray

Pain

ting

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

• • • • • • • • •

• • • • • • • • • •• • • • •

• • •

• • • • • •• • • • •

• • • •• • • • •

• • • • •

• • • •

• •• • • • • • • • •

• • • •

• • • • • • • • •• • • • • • • • •

•• • •

• • • •

Page 23: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

23Customer Service Center: 1-800-MSA-2222 • Website: www.MSAnet.com • Quicklit Fax Information: 1-800-672-9010 • MSA International: 1-412-967-3354

Instruments& Industries

Expl

osim

eter

® Co

mbu

stib

leGa

s Ind

icato

r

Gasc

ope®

Com

bust

ible

Gas I

ndica

tor

PULS

AR™

Singl

e-Ga

s Det

ecto

r

PULS

AR+

Singl

e-Ga

s Det

ecto

r

Resp

onde

r® A

larm

s

Tank

scop

e®,M

odel

62T

Com

bust

ible

Gas

Indi

cato

r

Titan

™ Co

mbu

stib

leGa

s Det

ecto

r

FiveS

tar®

Ala

rm

Micr

oGar

d® Po

rtabl

e Ala

rms

Orio

n® M

ultig

as D

etec

tor

Orio

n G

Mul

tigas

&Le

ak D

etec

tor

Pass

port®

Perso

nal A

larm

Wat

chm

an®

Mul

tigas

Mon

itor

Calib

ratio

n Ch

eck K

its

Dete

ctor

Tube

s

Pass

port®

PID

II Org

anic

Vapo

r Mon

itor

Pass

port®

VOC

2000

Org

anic

Vapo

r & O

xyge

n M

onito

r

Sam

plin

g Pu

mps

PORT

ABLE

INST

RUM

ENTS

Utilt

ies

Wel

ding

Wat

er &

Was

tew

ater

Trea

tmen

t

Application/Task Gas/Hazard

home furnace leaks CO

gas service safety surveyand leak detection, Combustible throughout processes Gases (CH4)

throughout processes H2S

fossil fuel power plants NO

fossil fuel power plants NO2

confined space O2 throughout processes Deficiency/Enrichment

fossil fuel power plants SO2

processing NH3

processing CO

digester process CO2

incinerators, stagnant gas in urbansewer system CO

processing Cl2

digester process, Combustible throughout process Gases (CH4)

sewer work, throughout process H2S

sewer treatment/maintenance, O2 confined space,throughout process Deficiency/Enrichment

dechlorinization process SO2

confined space welding,arcair cutting, digester processflux- & gas-shielded arc welding, metal cutting & flame gouging,gas pressure welding CO

thermite arc & studwelding,laser welding & chilling,arcair cutting, digester processelectric resistance welding,gas pressure welding,metal cutting & Combustible flame gouging Gases

Dust & Particulate

NO

arc welding & cutting,stud welding,arcair cutting,gas pressure welding,metal cutting & flame gouging NO2

confined space welding, O2 electron beam welding Deficiency/Enrichment

arc welding & cutting,stud welding,arcair cutting,electric resistance welding Ozone

• • • • • • • • • •• • • • • • • • • • •

• • • • • • • • • • • •• • • •• • • • •

• • • • • • • • • •• • • • •

• • • • •• • • • • • • • •

• •• • • • • • • •

• • • • • •• • • • • • • • • •

• • • • • • • • • • •• • • • • • • • •

• • • • •

• • • • • • • • •

• • • • • • • • • •

•• • •

• • • • •

• • • • • • • • •

• •

Single-Gas Multigas PIDs, Sampling Pumps &Instruments Instruments Calibration Accessories

Page 24: Portable Instrument Selection Guidemedia.msanet.com/NA/USA/PortableInstruments/ToxicGasandOxygen... · Advanced Technology Advanced technology in research and development as well

Exposure LimitsTerms and AbbreviationsIDLH (Immediately Dangerous to Life and Health)*– Themaximum concentration level of a substance (gas) from which a workercould escape within 30 minutes without developing immediate, severe orirreversible health effects, or other escape-impairing symptoms. IDLH levelsare measured in ppm (parts per million). * As defined by NIOSH (NationalInstitute for Occupational Safety and Health).

PEL (Permissible Exposure Limit) – An airborne concentration ofcontaminant that most workers can be exposed to repeatedly in a normal 8-hour day, in a 40-hour week, without adverse health effect. PEL levels aremeasured in ppm (parts per million) and are established by OSHA.

PPM (Parts Per Million) – The most common unit of measurement fortoxic gases. “10,000 parts per million” gas concentration equals 1% byvolume.

TLV (Threshold Limit Value)* – Refers to the airborne concentrationof substances to which most workers can be repeatedly exposed over aworking lifetime without adverse effects.* As defined by ACGIH (American Conference of Governmental Industrial Hygienists).

There are three categories of TLVs:

TLV – TWA (Time Weighted Average) – This is the averageamount of gas that a worker can be repeatedly exposed to in a normal8-hour day, in a 40-hour week, without adverse health effects.

TLV – STEL (Short Term Exposure Limit) – The gasconcentration that most workers can be continuously exposed to for a15-minute time period without suffering adverse health affects thatwould impair self-rescue or worker safety. This limit should not berepeated more than 4 times per day and there should be at least 60minutes between individual STEL exposure periods.

TLV – C (Ceiling) – The highest gas concentration to which workersmay be exposed. Ceiling TLVs should never be exceeded and they takeprecedence over all TWAs and STELs.

LEL (Lower Explosive Limit) – The lowest concentration of a gas orvapor that will ignite and sustain combustion. “% LEL” is a common unit ofmeasurement in combustible gas detection.

UEL (Upper Explosive Limit) – The maximum concentration at whicha gas will sustain combustion.

Oxygen Deficient Atmosphere – An atmosphere containing lessthan 19.5% oxygen by volume. (Possesses a risk of insufficient oxygen forbreathing.)

Oxygen Enriched Atmosphere – An atmosphere containing morethan 25% oxygen by volume. (Possesses an increased risk of explosion.)

Note: This Bulletin contains only ageneral description of the productsshown. While uses and performancecapabilities are described, under nocircumstances shall the products be used by untrained or unqualifiedindividuals and not until the product instructions including any warnings or cautions provided have been thoroughly read andunderstood. Only they contain thecomplete and detailedinformation concerningproper use and care ofthese products.

ID 0800-11-MC / Nov 2002© MSA 2002 Printed in U.S.A.

Corporate HeadquartersP.O. Box 426, Pittsburgh, PA 15230 USAPhone 412-967-3000www.MSAnet.comU.S. Customer Service CenterPhone 1-800-MSA-2222Fax 1-800-967-0398MSA CanadaPhone 1-800-MSA-2222Fax 905-238-4151MSA Mexico Phone 52-55 21 22 5770Fax 52-55 359 4330MSA International Phone 412-967-3354 Fax 412-967-3451

Offices and representatives worldwideFor further information: