Made in Canada INTEGRITY INNOVATION PERFORMANCE Water Storage Guide AWWA D-102

Upload: others

Post on 01-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Potable Water Storage Tank Guide - Cloverdale Paint

Made in Canada

INTEGRITY • INNOVATION • PERFORMANCE

Water Storage GuideAWWA D-102

Page 2: Potable Water Storage Tank Guide - Cloverdale Paint

AWWA Designation

AWWA Designation

Primer Intermediate Topcoat

Primer Intermediate AWWA Min. DFTTopcoat

Outs

ide

Coat

ing

Syst

em (O

CS)

Insi

de C

oatin

g Sy

stem

s (IC

S)

ICS-1Lifelast Primall Epoxy

Lifelast Primall Epoxy

LifeLast DuraShield

Tank Guard DW

Tank Guard DW

Tank Guard DW

Tank Guard 412

LifeLast DuraShield

Tank Guard DW

Tank Guard DW

Tank Guard 412 Tank Guard 412

10 mils

20 mils

12 mils

8 mils

NSP Liquitile 1172 NSP Liquitile 1172

Tank Guard 412

Tank Guard DW

Tank Guard DW

ICS-2

ICS-3

ICS-4 No System Available

*

*

ICS-5

OCS-1-C 71044 Rustex 749 Marine & Maintenance 749 Marine & Maintenance

ClovaMastic 83110 Armour Shield 837/839

Armour Shield 837/839ClovaMastic 83110

ClovaZinc 3

ClovaMastic 83110

OCS-3

OCS-4Alternate

Barrier (Field)Resist 86 (Shop)

Ecologic 703 SeriesSpeed Enamel

Ecologic 703 SeriesSpeed Enamel

Hardtop Optima Polysiloxane

ClovaZinc 3 (Field)ClovaZinc 2 (Shop)

OCS-5

OCS-6

WATER STORAGE GUIDE AWWA D-102

AWWA Designation Primer Intermediate Topcoat

*Cloverdale does not recommend Zinc Rich primers for use in immersion service for potable water.

Page 3: Potable Water Storage Tank Guide - Cloverdale Paint

WATER STORAGE GUIDE AWWA D-102

1. All coating systems listed for OCS will meet VOC regulations for Field Applied Coatings.

2. Alternate coatings are available for shop applied coatings, as your Cloverdale Technical Representative.

3. Coatings suggested in this guide conform to the AWWA D102 standard. Systems provided don’t notnecessarilyreflectmaximumfilmbuildsandmaybeapprovedforadditionalfilmthickness

where required. Consult your Cloverdale Technical Representative for details.

4. Thesystemspecifiedisbasedonneworbaresteelsubstrates.ConsultyourCloverdaleTechnical Representative for optional overcoat systems if applicable.

5. ConsultyourCloverdaleTechnicalRepresentativetoensuretheNSF61andULcertificationis valid for the volume of your tank.

6. Coatings shall be applied in accordance with the product TDS.

Page 4: Potable Water Storage Tank Guide - Cloverdale Paint