Chamber Brite Chamber Brite™ - Powdered Autoclave Cleaner No Mess, No Hassles, No Measuring... Chamber Brite powder is simply the easiest way to keep autoclaves clean and free of water deposit build-up. Designed specifically for steam sterilizers, Chamber Brite effectively cleans and descales the chamber, tubing and reservoir in minutes. Convenient, pre-measured packets Cleans chamber, tubing and reservoir Uses less storage space Replaces messy liquid cleaners 1 9 2 5 -2 0 1 5 YEARS

Upload: lexuyen

Post on 12-May-2019

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Powdered Autoclave Cleaner Chamber Brite · Chamber Brite ™ Chamber Brite™ - Powdered Autoclave Cleaner No Mess, No Hassles, No Measuring... Chamber Brite powder is simply the

ChamberBrite ™

Chamber Brite™ - Powdered Autoclave Cleaner

No Mess, No Hassles, No Measuring...Chamber Brite powder is simply the easiest way to keep autoclaves clean and free of water deposit build-up. Designed specifically for steam sterilizers, Chamber Brite effectively cleans and descales the chamber, tubing and reservoir in minutes.

• Convenient, pre-measured packets• Cleans chamber, tubing and reservoir• Uses less storage space• Replaces messy liquid cleaners

1925-2015

YEARS

EZPLUS & EZ SERIES FULLY AUTOMATICSTERILIZERS FROM TUTTNAUER

Only Tuttnauer Gives You More Choices

9”, 10” or 11” Sizes • Closed Door Drying2 Year Parts & Labor Warranty

Tel: (800) 624 5836, (631) 737 4850Email: [email protected], www.tuttnauerUSA.com

Tuttnauer EZ AutoclavesNEW Tuttnauer EZPlus Autoclaves

Page 2: Powdered Autoclave Cleaner Chamber Brite · Chamber Brite ™ Chamber Brite™ - Powdered Autoclave Cleaner No Mess, No Hassles, No Measuring... Chamber Brite powder is simply the

2 53 64 7 8

Chamber Brite™ - Powdered Autoclave Cleaner

LTR330-0009/U

LF/USA

/V-3/07.15

Refill the reservoir with clean steam distilled water. Note: EZ models top fill only EZPlus models top and front fill available

Run a clean water cycle repeating steps 2, 3 & 4 BUT WITHOUT USING CHAMBER BRITE.This will remove any residue from the internal plumbing.

At the end of a cleaning cycle, open the chamber door and use the drain valve and drain hose to drain all of the water out of the reservoir into a pail. The Chamber Brite solution is in the waste water.

Water will begin to flow in from the back of the chamber. Monitor the flowuntil it gets to the indentation line at the front of the chamber.

The pressure gauge will rise to 30psi and when the timer reaches “Zero” the bell will ring. Immediately turn the multivalve to “EXH+DRY” and the dirty water in the chamber will be forced out and back into the water reservoir

Repeat steps 2, 3, 4, 5, 6, 7 & 8 BUT WITHOUT USING CHAMBER BRITE.

This will remove anyresidue from the internalplumbing.

TURN THE AUTOCLAVE OFF AND ALLOW THE CHAMBERTO COOL. Once the chamber is cool, wipe the inside of the chamber and the water sensor at the rear with a damp cloth or sponge to remove any residue.Cleaning the dirt off the sides of the sensor is more important than the tip. The unit is now ready to sterilize.

*Cleaning Instructions: EZPlus, EZ and EA Autoclaves

*Cleaning instructions: Manual Autoclaves

1

1

4

7

4

2

2

5

8

10

5

3

3

6

9

6

Cleaning needs to be done on a COLD chamber. Open the door and spread the ChamberBrite™ in a straighteven line along the bottomof the chamber, from back to front. Do not leave a pile of Chamber Brite in one spot

Cleaning needs to be done on a COLD chamber. Open the door and spreadthe ChamberBrite™ in a straight even line along the bottom of the chamber, from back to front. Do not leave a pile of Chamber Brite in one spot

Turn the multivalve to“STERILIZE” (OLDER modelsare labeled “STE”) Closeand lock the door

Once the pressure gaugereaches “ZERO”, open thechamber door and use thedrain valve and drain hose to drain ALL of the water out of the water reservoir into a pail. flush the reservoir with clean water. The Chamber Brite solution is in the waste water

Tuttnauer USA Co., Ltd. 25 Power Drive, Hauppauge, NY 11788 Tel: +800 624 5836, +631 737 4850 Fax: +631 737 0720E-mail: [email protected], www.tuttnauerUSA.com

2 3 4

EZPlus models: Select Chamber Brite cleaning program, close the door and start the cycle.

EZ & EA models: Select the Unwrapped cycle, start a cleaning cycle WITH WATER and NO DRYING CYCLE.

Make sure the waterreservoir is filled withsteam distilled water. Set temperature to 273˚F (134˚F). With the chamber door OPEN, turn the multivalve clockwise from“0“ to “FILL WATER “.

For Valueklave or any “MK” models, set timer to 12 minutes

For all other “M” models, set the timer to 30 minutes

Tighten the drain valve.Refill the water reservoir with clean steam distilled water

TURN THE AUTOCLAVE OFF AND ALLOW THE CHAMBERTO COOL. Once the chamber is cool, wipe the inside of thechamber with a damp cloth or sponge to remove any residue.

For best results, clean autoclave every 20 cycles or once per week as needed. It is essential to follow the equipment manufacturer’s directions for cleaning and maintenance. *For full instructions on how to use Chamber-Brite -follow the directions on the box. (Chamber Brite is not to be used in the Elara11 Pre/Post Vacuum Class B Sterilizer