Power & Control Equipment
Section 4
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Power & Control Equipment
Section 4
Power and control are at the heart of the lighting control systemforanyairfield.TheFederalAviationAdministrationhassetforth standards dictating how fixturesandsignsmaybepoweredand controlled.
Crouse-HindsAirportLightingProducts has the constant currentFerro-resonantand seriestyperegulatorsina varietyofsizesforallairports.Ourregulators and control geararedesignedtoprovide
precisioncontrolofairfieldcircuitsandinterfacewithawidearrayofcontrol and monitoring options.
Power Vault Lighting Control
Application Icons
4.1
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Section Head
REGFConstant Current Regulators - FerroresonantCompliances: FAAAC150/5345-10:L-828 ICAOAerodromeDesignManual,Part5
Small/4-10kWUnit
ApplicationsTheREGFConstantCurrentRegula-torisdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.TheFerroresonant core design runs more efficienctly.TheFerroresonantdesignalsocreatesacleanersinewavethatfunctionstoimprovecommunica-tion on the power lines and helps to prolong the life of the lamps on the circuit.Theequipmentcanbesup-plied with a wide range of control and monitoring options.
These regulators are air cooled and designedforindoorservice.
Features � ETLCertified � LowTotalHarmonicDistortion(THD)<10%
� Cleanoutputsinusodialwaveform � Stackabledesign(3HighMax) � SoftOn/Off � Air cooled � Ferroresonant Design � Built-indigitalammeter (0.5%accuracy)
� Regulation±1%over0to100%loadand+10%to-5%line voltagewithnotapchanges
� On-offswitchingunderload � Lightningandtransientprotection:
input and output lines � Efficiency–90%minimum (Highstep,fullyloaded)
� Highpowerfactor.99 (Highstep,fullyloaded)
� Remoteresetcapability � Output current maintained
with 30% open isolation transformer secondaries
� Open circuit protection � Overcurrentprotection � 10,000 feet remote control @120V
� Temperature–40°Cto+55°C � Singlecontrolboardforallsizes � Rotaryswitchforstep-control � Fieldselectablebrightness
steps (1, 3, 5) � Hingedfrontdoorwithhandle
CCRType: 8 =L-828
Frequency: 60 = 60Hz
RegulatorType: F = Ferroresonant
InputVoltage: 208 = 208V,60Hz 220 = 220V,60Hz 240 = 240V,60Hz 480 = 480V,60Hz
KilowattRating: 04 = 4.0kW 07 = 7.5kW 10 = 10kW
OutputBrightnessSteps: 1 = 1 Step (5.5A) 3 = 3Step(4.8,5.5&6.6A) 5 = 5Step(2.8,3.4,4.1,5.2&6.6A)
Options: B = Integralcircuitbreaker C = Computerreadyinterface* CA = IntergralS-1Cutout,Integralcircuitbreaker,Green/YellowGrounding Wires per Canadian Electrical Standards D = Digitrac™computerizedcontrolandmonitoringsystem (IncludesoptionC) M2 = IntegralMegatracearthleakdetector(includesoptionS2)** S2 = IntegralS-1Cutout S506A = Load Volts Metering** V = DCRemoteControl,internallysupplied(24,48&60VDC)
* Includespotentialandcurrenttransformersandrelaycontactsforindicationof loss of input power and local/remote control. ** RegulatorcannotbeorderedwithbothM2andS506Aoptions.
Standardremotecontrolvoltageis120VAC.
Power & Control Equipment
Ordering Information
- - - 8 2 8 6 0 F -
EATON’S CROUSE-HINDS BUSINESS4.2
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Dimensions: Inches (mm)
InstructionManual: 2501
4Kw 7.5kW 10kWShippingWeight: 490lbs. 581lbs. 711lbs. 222kg. 264kg. 323kg.
ShippingVolume: 9.2cu.ft. 9.2cu.ft. 9.2cu.ft. 0.26 cu.m. 0.26 cu.m. 0.26 cu.m.
Power Factor/Efficiency Data (100% load/10kw)
5-BrightnessStepCCR
Step (output) Power Factor Efficiency%
B5(6.6A) 0.99 93%
B4(5.2A) 0.98 93%
B3(4.1A) 0.98 91%
B2(3.4A) 0.98 89%
B1(2.8A) 0.79 84%
Outline Drawing
LOCALCONTROLSWITCH
1
2
3
45
OFFREMOTE
DANGERWHEN THE REGULATOR IS ENERGIZED
HIGH VOLTAGE PRESENT INSIDE CABINET
WINDSOR, CT U.S.A.SERIAL NUMBER
!
PART NUMBER
INPUT: VOLTS, Hz, A @ KW
CONTROL: VOLTS, Hz
SINGLE PHASECONSTANT CURRENT REGULATOR
3 4.8, 5.5, 6.6A 5 2.8, 3.4, 4.1, 5.2, 6.6A
BRIGHTNESS STEPS OUTPUT CURRENT
OUTPUT: KW @ 6.6A
IDENTIFICATION: FAA L-828 FAA L-829
PowerTrac TM
26.5(673.1)
24.0(609.6)
25.0(635)
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
15PINCableAssembly 34070Capacitor, 50uF, 660 VAC 32990KIContactor 10047-1249Switch&Displayprintedcircuitcard 32752Fuse1A,5x50mm 10047-2890Fuse125MA,5x20mm 10047-2889Fuse2A,5x20mm 10047-2920InterconnectP.C.Board 34054-1LA1LightingArrestor 10047-885LA2&LA3LightingArrestor,3kv 10053-703
Main printed circuit card, 120VACinternalcontrolvoltage 34031-1*Main printed circuit card, forusewithOptionV 34031-1V*DisplayMainPCBDRibbonCable 10047-2826SolidStateRelay&ThermalPad 34207Switchknob 10041-31RVIVaristor 10047-1297
* SerialNumberunitspriorto300consultfactory.
4.3
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
REGFConstant Current Regulators - FerroresonantCompliances: FAAAC150/5345-10:L-828 ICAOAerodromeDesignManual,Part5
Medium/15-20kWUnit
ApplicationsTheREGFConstantCurrentRegula-torisdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.TheFerroresonant core design runs more efficienctly.TheFerroresonantdesignalsocreatesacleanersinewavethatfunctionstoimprovecommunica-tion on the power lines and helps to prolong the life of the lamps on the circuit.Theequipmentcanbesup-plied with a wide range of control and monitoring options.
These regulators are air cooled and designedforindoorservice.
Features � ETLCertified � LowTotalHarmonicDistortion(THD)<10%
� Cleanoutputsinusodialwaveform � Stackabledesign(2HighMax) � SoftOn/Off � Air cooled � Ferroresonant Design � Built-indigitalammeter (0.5%accuracy)
� Regulation±1%over0to100%loadand+10%to-5%line voltagewithnotapchanges
� On-offswitchingunderload � Lightningandtransientprotection:
input and output lines � Efficiency–90%minimum (Highstep,fullyloaded)
� Highpowerfactor.99 (Highstep,fullyloaded)
� Remoteresetcapability � Output current maintained
with 30% open isolation transformer secondaries
� Open circuit protection � Overcurrentprotection � 10,000 feet remote control @120V
� Temperature–40°Cto+55°C � Singlecontrolboardforallsizes � Rotaryswitchforstep-control � Fieldselectablebrightness
steps (1, 3, 5) � Hingedfrontdoorwithhandle
CCRType: 8 =L-828
Frequency: 60 = 60Hz
RegulatorType: F = Ferroresonant
CabinetSize: 1 = Mid-Size
InputVoltage: 208 = 208V,60Hz 220 = 220V,60Hz 240 = 240V,60Hz 480 = 480V,60Hz
KilowattRating: 15 = 15kW,6.6A 20 = 20kW,6.6A 16 = 15kW,20A 21 = 20kW,20A
OutputBrightnessSteps: 1 = 1Step(5.5A)-6.6Aunitsonly 3 = 3 Step 5 = 5 Step
Options: B = Integralcircuitbreaker C = Computerreadyinterface* CA = IntergralS-1Cutout,Integralcircuitbreaker,Green/YellowGrounding Wires per Canadian Electrical Standards D = Digitrac™computerizedcontrolandmonitoringsystem (IncludesoptionC) M2 = IntegralMegatracearthleakdetector(includesoptionS2)** S2 = IntegralS-1Cutout S506A = Load Volts Metering** V = DCRemoteControl,internallysupplied(24,48&60VDC)
* Includespotentialandcurrenttransformersandrelaycontactsforindicationof loss of input power and local/remote control. ** RegulatorcannotbeorderedwithbothM2andS506Aoptions.
Standardremotecontrolvoltageis120VAC.
Power & Control Equipment
Ordering Information
- - - - 8 2 8 6 0 F 1
EATON’S CROUSE-HINDS BUSINESS4.4
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Power Factor/Efficiency Data (100% load/20kw)
5-BrightnessStepCCR
Step (output) Power Factor Efficiency%
B5(6.6A) 0.99 91%
B4(5.2A) 0.98 90%
B3(4.1A) 0.98 89%
B2(3.4A) 0.91 87%
B1(2.8A) 0.71 84%
Outline Drawing
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
CONTROLSWITCH
LOCAL
5 4
3
2
REMOTE OFF
1
BRIGHTNESS STEPS OUTPUT CURRENT
5 2.8, 3.4, 4.1, 5.2, 6.6A 3 4.8, 5.5, 6.6A
CONSTANT CURRENT REGULATOR
INPUT: VOLTS, Hz, A @ KW
WINDSOR, CT U.S.A.
HIGH VOLTAGE PRESENT INSIDE CABINETWHEN THE REGULATOR IS ENERGIZED
DANGER
OUTPUT: KW @ 6.6A
CONTROL: VOLTS, Hz
PART NUMBER
SERIAL NUMBER
!
IDENTIFICATION: FAA L-828
SINGLE PHASE
PowerTrac TM
FAA L-829
39.75(1009.6)
30.0(762)
25.0(635)
Dimensions: Inches (mm)
InstructionManual: 2334
15kW 20kWShippingWeight: 860lbs. 1070lbs. 390kg. 485kg.
ShippingVolume: 13.8cu.ft. 13.8cu.ft. 0.39 cu.m. 0.39 cu.m.
15PINCableAssembly 34070Capacitor, 50uF, 660 VAC 32990Kl Contactor, 95A 32084Kl Contactor, 120A 32085SwitchDisplayprintedcircuitcard 32752Fuse1A,5x50mm 10047-2890Fuse125MA,5x20mm 10047-2889Fuse2A,5x20mm 10047-2920InterconnectP.C.Board 34054-1LA1LightingArrestor 10047-885
LightingArrestor,3kv(6.6ACCR) 10053-703LightingArrestor,6kv(6.6ACCR) 10053-704Main printed circuit card, 120 VAC internal controlvoltage 34031-1Main printed circuit card, forusewithOptionV 34031-1VDisplay/SwitchRibbonCable 10047-2826K2SolidStateRelay&ThermalPad 34207Switchknob 10041-31RVIVaristor 10047-1297
4.5
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
REGFConstant Current Regulators - FerroresonantCompliances: FAAAC150/5345-10:L-828 ICAOAerodromeDesignManual,Part5
Large/30kWUnit
ApplicationsTheREGFConstantCurrentRegulator isdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.The Ferroresonant core design runs more ef-ficienctly.TheFerroresonantdesignalsocreatesacleanersinewavethatfunctionstoimprovecommunicationonthepowerlines and helps to prolong the life of the lampsonthecircuit.Theequipmentcanbesupplied with a wide range of control and monitoring options. These regulators are air cooled and designedforindoorservice.
Features � ETLCertified � LowTotalHarmonicDistortion(THD)<10% � Cleanoutputsinusodialwaveform � Stackabledesign(2HighMax) � SoftOn/Off � Air cooled � Ferroresonant Design � Built-indigitalammeter(0.5%accuracy) � LowTotalHarmonicDistortion(THD)<10% � Cleanoutputsinusodialwaveform � Stackabledesign(2HighMax) � Regulation±1%over0to100%loadand+10%to-5%linevoltagewithnotapchanges
� On-offswitchingunderload � Lightningandtransientprotection:input
and output lines � Efficiency–90%minimum(Highstep,fully
loaded) � Highpowerfactor.99(Highstep,fully
loaded) � Remoteresetcapability � Output current maintained with 30% open
isolation transformer secondaries � Open circuit protection and Overcurrentprotection
� 10,000feetremotecontrol@120V � Temperature–40°Cto+55°C � Singlecontrolboardforallsizes � Rotaryswitchforstep-control � Fieldselectablebrightness
steps (1, 3, 5) � Hingedfrontdoorwithhandle
CCRType: 8 =L-828
Frequency: 60 = 60Hz
RegulatorType: F = Ferroresonant
CabinetSize: 2 = Full-Size
InputVoltage: 208 = 208V,60Hz 220 = 220V,60Hz 240 = 240V,60Hz 480 = 480V,60Hz
KilowattRating: 30 = 30kW,6.6A 31 = 30kW,20A
OutputBrightnessSteps: 1 = 1 Step (5.5A) 3 = 3Step(4.8,5.5&6.6A) 5 = 5Step(2.8,3.4,4.1,5.2&6.6A)Options: B = Integralcircuitbreaker C = Computerreadyinterface* CA = IntergralS-1Cutout,Integralcircuitbreaker,Green/YellowGrounding Wires per Canadian Electrical Standards D = Digitrac™computerizedcontrolandmonitoringsystem (IncludesoptionC) M2 = IntegralMegatracearthleakdetector(includesoptionS2)** S2 = IntegralS-1Cutout S506A = Load Volts Metering** V = DCRemoteControl,internallysupplied(24,48&60VDC)
* Includespotentialandcurrenttransformersandrelaycontactsforindicationof loss of input power and local/remote control. ** RegulatorcannotbeorderedwithbothM2andS506Aoptions.
Standardremotecontrolvoltageis120VAC.
Power & Control Equipment
Ordering Information
- - - - 8 2 8 6 0 F 2
EATON’S CROUSE-HINDS BUSINESS4.6
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Power Factor/Efficiency Data (100% load/30kw)
5-BrightnessStepCCR
Step (output) Power Factor Efficiency%
B5(6.6A) 0.99 93%
B4(5.2A) 0.98 91%
B3(4.1A) 0.98 90%
B2(3.4A) 0.92 88%
B1(2.8A) 0.74 85%
Outline Drawing
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
CONTROLSWITCH
LOCAL
5 4
3
2
REMOTE OFF
1
BRIGHTNESS STEPS OUTPUT CURRENT
5 2.8, 3.4, 4.1, 5.2, 6.6A 3 4.8, 5.5, 6.6A
CONSTANT CURRENT REGULATOR
INPUT: VOLTS, Hz, A @ KW
WINDSOR, CT U.S.A.
HIGH VOLTAGE PRESENT INSIDE CABINETWHEN THE REGULATOR IS ENERGIZED
DANGER
OUTPUT: KW @ 6.6A
CONTROL: VOLTS, Hz
PART NUMBER
SERIAL NUMBER
!
IDENTIFICATION: FAA L-828
SINGLE PHASE
PowerTrac TM
FAA L-829
39.75(1009.6)
36.0(914.4)
25.0(635)
Dimensions: Inches (mm)
InstructionManual: 2349
ShippingWeight: 1,635lbs. 742kg.
ShippingVolume: 20.7cu.ft. 0.58 cu.m.
15PINCableAssembly 34070Capacitor, 50uF, 660 VAC 32990Displayprintedcircuitcard 32752KIContactor,200A 10047-2774KIContactor,120A 32085Fuse125MA,5x20mm 10047-2889Fuse2A,5x20mm 10047-2920InterconnectP.C.Board 34054-1LA1LightingArrestor 10047-885LightingArrestor,3kv(20ACCR) 10053-703LightingArrestor,6kv(6.6ACCR) 10053-704
Main printed circuit card, 120VACinternalcontrolvoltage(standard) 34031-1Main printed circuit card, forusewithOptionV 34031-1VDisplay/SwitchRibbonCable 10047-2826K2SolidStateRelay&ThermalPad 34207Switchknob 10041-31RVIVaristor 10047-1297
4.7
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
C-SGSCabinet - SwitchgearCompliances: UL891
Combinations(Specifyinstallationlineuplefttoright):
AirportCode:
ProjectNumber:
Power & Control Equipment
Ordering Information
- 8 2 8 S Y S -
ApplicationsTheCrouse-HindsSwitchgearSystem(SGS)utilizesaUL compliantbusforthedistributionof electrical power and the precisioncontrolofairfieldlightingcircuits.TheequipmentmeetsallapplicableULandNEMAstan-dards, integrates enhancedsafetyfeatures,providesforcost-effectiveinstallationandserviceability,isair-cooledanddesigned for indoor installations.
Thebenefittoinstallinga CCHSGSishavingallthe energyequipmentinasmallerareaandwhenaCCRneedstobereplaced,thenonlythecorecanbechangedprovidingahugelongtermcostsavings.
Features � ComplieswithUL891, standardfordead-front switchboard
� NEMA1cabinet
� Seismiczone4ratedsystem
� 65,000AICbusbracing
� 800 Amp copper main horizontalbuswithdeadfront
� 300Ampcoppergroundbus
� Fieldchangeable(CCR-SGS)loadbalancing
� Modulardesignforeasy add-onfieldinstallations
� Allcabinetsystemsareshippedinmodularformat.Assemblyrequired.
� Rated for 480 VAC
� Tworegulators(CCR-SGS) percabinet
Maximum Bus Bar System Capacity:280 kW (at 480V, Input Voltage)
CCR-SGS
PowerRequirementsData
480V,Input
CCR(Rated Current)
04kw 9 A
7.5kW 17 A
10kW 23 A
15kW 34 A
20kW 46 A
30kW 69 A
EATON’S CROUSE-HINDS BUSINESS4.8
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Outline Drawing
Renewal Parts
Description PartNumber Description PartNumber
Dimensions: Inches (mm)
InstructionManual: 2516
ShippingWeight: MainInputCabinet-700lbs. AuxiliaryCabinet-700lbs. ConstantCurrentRegulatorCabinet-1200lbs.
AuxiliaryCabinet 34125-XConstantCurrentRegulatorCabinet (2powermodules) 34192-XLowerTrackExtension 34127-HT
Note:Consultinstructionmanualand/orfactoryforassistance.
Maininputcabinet&circuitbreaker 34122-XS1Cabinet 34124-XUpperTrackExtension 34126-HT
3
2
1
5 4
LOCALCONTROLSWITCH
OFFREMOTE
CONTRAST
SETUP
ENTER
tracPower TM
FUNCTION
DEVICE
MAININPUT
CU
TOU
T
CU
TOU
T
CU
TOU
T
CU
TOU
T
CONSTANT CURRENTREGULATOR CABINET
AUXILARY CABINETFOR CCS
S-1 CABINET
FRONT VIEW
BOTTOM VIEW
P/N 34122 P/N 34192 P/N 34125 P/N 34124
VIEW SHOWNWITHOUT DOOR
98.0(249)
5.0 (12.7)
15.0(38)
20.0(51)
36.0 (91)TYP.
10.0(25.4)
10.0(25.4)TYP.
2.5 (6.4)TYP.
1.9 (4.8)TYP.
6.0 (15)TYP.
31.0 (79)TYP.
30.0˝(76)TYP.
38.0˝(97)TYP.
42.0˝(107)TYP.
16.0(41)TYP.
PER SECTIONØ0.625 (16 mm)TYP. (4)
128.0 (325)
4.9
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CCR-SGSConstant Current Regulator - Switchgear SystemCompliances: FAAAC150/5345-10:L-828
ApplicationsTheCrouse-HindsConstant CurrentRegulator-Switchgear System(CCR-SGS)utilizes Ferroresonant Transformer technologyforthedistributionofelectrical power and the precision controlofairfieldlightingcircuits.Theequipmentmeetsall applicableFAAstandards, integratesenhancedsafety features,providesforcost-effectiveinstallationandserviceability,isair-cooledanddesignedforindoorinstallations.
Features � ETLCertified
� Superior power factor and efficiencyoverallsteps (RefertoTableA,nextpage)
� Superiorlow-lineharmonics andlowEMIcharacteristics
� Standardized design for maximum space utilization
� Modular construction for interchangeability
� IntegratedModel2S-1Cutoutpro-videsaddedsafetyduringservicing
� Diagnostic LEDs, and digital am-meter for enhanced troubleshootingcapabilities
� Capabilityforlineandloadcircuitswitching while in operation
� Lightningprotectionforboth input and output lines
� Integratedsoftstartandremotereset functions
� Internal120VACControlVoltage
� IntegralCircuitBreaker
� RotarySwitchoff/remote &stepcontrol
� Air Cooled
� DesignedforIndoorInstallation
� Switchgearsystemincludes coremoduleandcabinetdoorwithallcircuitry
CCRType:L-828
SwitchgearCCRModel:
RegulatorType: F = Ferroresonant
InputVoltage: 480 = 480V,60Hz
KilowattRating: 04 = 4.0kW(6.6AUnitOnly) 07 = 7.5kW(6.6AUnitOnly) 10 = 10kW(6.6AUnitOnly) 15 = 15kW,6.6A 16 = 15kW,20A 20 = 20kW,6.6A 21 = 20kW,20A 30 = 30kW,6.6A 31 = 30kW,20A
OutputBrightnessSteps: 1 = 1Step(5.5A,notavailablewith20Aunits) 3 = 3 Step 5 = 5 StepOptions: C = Computerreadyinterface* D = Digitrac™computerizedcontrol&monitoringsystem (includes option C) M = Megatrac™Integralearthleakagedetector N = Nocabinetdoorincluded,onlycoremoduleforretrofitpurposes V = DCRemoteControl,internallysupplied(24,48&60VAC)
* Potential¤ttransformerincluded,CircuitBoardwithrelaycontacts forlossofinputpower&local/remotecontrol.
Standardremotecontrolvoltageis120VAC.
Power & Control Equipment
Ordering Information
- - - - 8 2 8 S G S
EATON’S CROUSE-HINDS BUSINESS4.10
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Dimensions: Inches (mm)
InstructionManual: 2447
4kW–10kW 15kW–20kW 30kWShippingWeight: 1230lbs. 1435lbs. 1650lbs. 558kg. 651kg. 748kg.
ShippingVolume: 36in.Wx48in.Dx57in.H
Table A – Power Factor/Efficiency Data (100% load)
5-BrightnessStepCCR 3-BrightnessStepCCR
Step (output)Power Factor Efficiency% Step (output)
Power Factor Step (output)
B5(6.6Aor20A) 0.99 94% B100(6.6Aor20A) 0.99 93%
B4(5.2Aor15.8A) 0.99 93% B30(5.5Aor16.5A) 0.98 91%
B3(4.1Aor12.4A) 0.94 91% B10(4.8Aor14.4A) 0.79 84%
B2(3.4Aor10.3A) 0.87 89% — — —
B1(2.8Aor8.5A) 0.79 81% — — —
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
Capacitor, 50uF, 660 VAC 32990Displayprintedcircuitcard 32752Main printed circuit card, 120VACinternalcontrolvoltage 34031-1
Main printed circuit card, forusewithOptionV 34031-1VK2SolidStateRelay&ThermalPad 34207SwitchKnob 10041-31
Outline Drawing
PULL HERE
DA
NG
ER
S-1 C
UT
OU
T
!
T5
T6
TB2
K1RV1
T2
K2
E1
E2
T3
T4
CB1
INP
T8
TB3CA
P1
CA
P2
DO NOT PULL ON SHEET METAL
T7
GND
INTINPUT
26.5(67.3)
38.5(97.8)
(4-10 kW)
43.8(111.2)
(15-30 kW)
4.11
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
REGWConstant Current Regulators-WetCompliances: FAAAC150/5345-10:L-828andL-829 ICAOAerodromeDesignManual,Part5 UFC3-535-01 USNNAVAIR51-50AAA-2
ApplicationsTheREGWConstantCurrentRegula-torisdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.Theequipmentcanbesuppliedwitha wide range of control and monitor-ing options.
These regulators are oil cooled and designedforindoorservice.
Features � ETLCertified(60HzOnly)
� Oilcooled(NoPCB’s), usesecofriendlymineraloil
� Advanceddiagnosticaids
� Shunttypeferro-resonant regulator
� SoftOn/Off
� Plug-inprintedcircuitboards
� SeparateHighVoltage compartment
� ElapsedTimeIndicator: each step and total
� Built-indigitalammeter (0.5%accuracy)
� Regulation±1%over0to100%loadand+10%to-5%line voltagewithnotapchanges
� On-offswitchingunderload
� Superior Lightning and transient protection:inputandoutputlines
� Efficiency—90%minimum
� Highpowerfactor
� Remoteresetcapability
� Output current maintained with 30% open isolation transformer secondaries
� Open circuit protection
� Overcurrentprotection
� CompatibilityofMultipleOptions
� IntegralL-829Monitoring
� 10,000 feet remote control @120V
� Temperature–40°Cto+55°C
CCRType: 828 = L-828 829 = L-829Frequency: 50 = 50Hz 60 = 60HzWetType: W = Oil Cooled
KilowattRating: 11 = 10kW 15 = 15kW 20 = 20kW 30 = 30kW 37 = 37.5kW(60HzOnly) 50 = 50kW 70 = 70kW(60HzOnly) (NotFAARecognized)InputVoltage:*** 1 = 20850/60Hz* 2 = 22050/60Hz* 3 = 23050Hz* 4 = 24050/60Hz**** 5 = 380,50Hz 6 = 400,50Hz 7 = 415,50Hz 8 = 480,60Hz 9 = 2400,60Hz**OutputCurrent: 66 = 6.6A* 20 = 20A(NotAvailableunder20kW)OutputBrightnessSteps: 01 = Fixed(HighestStep) 03 = 3 Steps 05 = 5 StepsOptions:See catalog page CCRO for a complete list of options.
* Notavailableabove30kW** Wyesystemisstandardwithone-polebreaker.ForDeltasystemseeOption94(Seepage4.19)***Only60HzInputVoltageisETLCertified****NotAvailableabove30kW50Hzand37.5kW60Hz
Power & Control Equipment
Ordering Information
- - W - - - -
EATON’S CROUSE-HINDS BUSINESS4.12
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
Fuse,1Amp,Slo-Blo 10047-1205Fuse,1/8Amp,Slo-Blo 10047-1005L-828ControlAssembly 32323-“X”-“Y”
L-829ControlAssembly 32323-“X”-“Y”-61SCR/HeatsinkAssembly,10-20KW 31505-1SCR/HeatsinkAssembly,30-70KW 31505-2
Outline Drawing
LIFTINGEYE
COOLINGRADIATOR
GROUNDLUG
OILDRAINVALVE
55.13(1400)
3.00 (76)
B
27.75(705)
A
CONTROLASSEMBLY KEYPAD
DIGITALDISPLAY
FRONTVIEW30KW,60HZUNITSHOWN
TOPVIEWOUTLINE
Dimensions: Inches (mm)
InstructionManual: 9525
Brightness Current Output Percentage (%)
Step 6.6ASystem 20ASystem Light Output
5 6.6 20.0 100.0
4 5.2 15.8 20.0
3 4.1 12.4 4.0
2 3.4 10.3 0.8
1 2.8 8.5 0.2
Shipping Weight Shipping Weight
KW Lb. Kg. Cu.Ft. Cu.M.
10 1575 715 103 2.92
15 1700 770 103 2.92
20 1825 830 103 2.92
30 2000 910 103 2.92
50 2600 1180 103 2.92
70 3000 1360 103 2.92
Radiators
KW A B R1 R2 R3
10 38.36(974)
27.75(705) — — —
15 43.19(1097)
27.75(705) Yes — —
20 43.19(1097)
27.75(705) Yes — —
30 43.19(1097)
31.63(803) Yes Yes —
50 43.19(1097)
38.25(972) Yes Yes Yes
70 43.19(1249)
38.25(972) Yes Yes Yes
Note:30kw,50Hzand37.5kw,usedataasshownfor50kw.
Insert1,3,or5inplaceof“X”forthenumberofbrightnessstepsrequired.Insert1for6,6Aor2for20Ainplaceof“Y”fortheoutputcurrentrequired.
4.13
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
REGDConstant Current Regulators-DryCompliances: FAAAC150/5345-10:L-828andL-829 ICAOAerodromeDesignManual,Part5 USNNAVAIR51-50AAA-2
Small/4-10kWUnit
ApplicationsTheREGDConstantCurrentRegula-torisdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.Theequipmentcanbe supplied with a wide range of control and monitoring options.
These regulators are air cooled anddesignedforindoorservice.
Features � ETLCertified(60HzOnly)
� Air cooled
� AdvancedDiagnosticAids
� Seriestransformertyperegulator
� SoftOn/Off
� ElapsedTimeIndicator: each step and total
� Built-indigitalammeter (0.5%accuracy)
� Regulation±1%over0to100%loadand+10%to-5%line voltagewithnotapchanges
� On-offswitchingunderload
� Lightning and transient protection:inputandoutputlines
� Efficiency–90%minimum
� Remoteresetcapability
� Output current maintained with 30% open isolation transformer secondaries
� Open circuit protection
� Overcurrentprotection
� CompatibilityofMultipleOptions
� IntegralL-829Monitoring
� 10,000 feet remote control @120V
� Temperature–40°Cto+55°C
� Plug-inprintedcircuitboards
� Circuitboardcompatible withlargedryCCR***
� Easyaccessslideoutdrawerforquickelectricaltroubleshootingandmaintenance
***Fieldadjustmentsmayberequired.
CCRType: 828 = L-828 829 = L-829Frequency: 50 = 50Hz 60 = 60HzDryType: D = Air CooledKilowattRating: 04 = 4.0kW 07 = 7.5kW 10 = 10kWInputVoltage:* 1 = 208,60Hz 2 = 220,50/60Hz 3 = 230,50Hz 4 = 240,50/60Hz 5 = 380,50Hz 7 = 415,50Hz 8 = 480,60HzOutputCurrent: 66 = 6.6 AmpsOutputBrightnessSteps: 01 = Fixed:FullBrightnessat6.6A 03 = 3 Steps 05 = 5 StepsOptions:See catalog page CCRO for a complete list of options.
*Only60HzInputVoltageisETLCertified
Power & Control Equipment
Ordering Information
- - D - - 6 6 - -
� Modularcontrolassembly
� Outputtapsproviderangeofefficientloadingoption
EATON’S CROUSE-HINDS BUSINESS4.14
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Dimensions: Inches (mm)
InstructionManual: 9517
4Kw 7.5kW 10kWShippingWeight: 250lbs. 325lbs. 370lbs. 114kg. 145kg. 168kg.
ShippingVolume: 17.6cu.ft. 17.6cu.ft. 17.6cu.ft. 0.50 cu.m. 0.50 cu.m. 0.50 cu.m.
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
L-828ControlAssembly-1Step 32322-1L-828ControlAssembly-3Step 32322-3L-828ControlAssembly-5Step 32322-5
Fuse,1Amp,Slo-Blo 10047-1205Fuse,1/8Amp,Slo-Blo 10047-1005
L-829ControlAssembly-1Step 32322-1-61L-829ControlAssembly-3Step 32322-3-61L-829ControlAssembly-5Step 32322-5-61
Q1&Q2SCR/HeatsinkAssembly, AllCCRsexceptbelow 31814Q1&Q2SCR/HeatsinkAssembly, 208-240VAC,10Kwunits 31817
Outline Drawing
REGDOutput Percentage (%)
Current (Amps) Light Output
BrightnessStep 3-Step 5-Step 3-Step 5-Step
5 — 6.6 — 100
4 — 5.2 — 20
3 6.6 4.1 100 4.0
2 5.5 3.4 30 0.8
1 4.8 2.8 10 0.2
Note:For10,15,20,and30KwshunttypeREGD regulators, refer to catalog page 4.2.
FRONTVIEW SIDEVIEW
2.0 (51)
FRONTOFUNIT
GROUNDINGSTUD
21.3 (541)
36.0*(914)
KEYPAD
CONTROLASSEMBLY
DIGITAL DISPLAY
CONDUITKNOCK-OUTAREA RIGHTANDLEFTSIDES
23.0 (584)
2.0 (51)
3.5 (89)
REMOVABLELIFTINGEYE
6.0 (152)
* The unit with options 41, 42, 43, or 44 is 12˝ higher.
4.15
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
REGDConstant Current Regulators-DryCompliances: FAAAC150/5345-10:L-828andL-829 ICAOAerodromeDesignManual,Part5 USNNAVAIR51-50AAA-2
Large/10-30kWUnit
ApplicationsTheREGDConstantCurrentRegula-torisdesignedtoprovideprecisioncontrolofrunwaylightingcircuits.Theequipmentcanbe supplied with a wide range of control and monitoring options.
These regulators are air cooled anddesignedforindoorservice.
Features � ETLCertified(60HzOnly) � Air cooled � Shunttypeferroresonant
regulator � SoftOn/Off � AdvancedDiagnosticAids � ElapsedTimeIndicator:
each step and total � Built-indigitalammeter (0.5%accuracy)
� Regulation±1%over0to100%loadand+10%to-5%line voltagewithnotapchanges
� On-offswitchingunderload � Lightning and transient protection:inputandoutputlines
� Efficiency—90%minimum � Remoteresetcapability � Output current maintained
with 30% open isolation transformer secondaries
� Open circuit protection � Overcurrentprotection � CompatibilityofMultipleOptions � IntegralL-829Monitoring � 10,000 feet remote control @120V
� Temperature–40°Cto+55°C � Plug-inprintedcircuitboards � Circuitboardcompatible withsmalldryCCR***
� Modularcontrolassembly designforquicktroubleshootingand replacement
CCRType: 828 = L-828 829 = L-829Frequency: 50 = 50Hz 60 = 60HzDryType: D = Air CooledKilowattRating: 11 = 10kW 15 = 15kW 20 = 20kW 30 = 30kWInputVoltage:* 1 = 208,50/60Hz 2 = 220,50/60Hz 3 = 230,50Hz 4 = 240,50/60Hz 5 = 380,50Hz 7 = 415,50Hz 8 = 480,60HzOutputCurrent: 66 = 6.6 A 20 = 20A(10kwavailablein6.6Ampsonly)OutputBrightnessSteps: 01 = Fixed:FullBrightnessat6.6A 03 = 3 Steps 05 = 5 StepsOptions:See catalog page 4.18 for a complete list of options.
*Only60HzInputVoltageisETLCertified**Wyesystemisstandardwithone-polebreaker.ForDeltaSystemseeOption94.
Power & Control Equipment
Ordering Information
- - D - - - -
***Fieldadjustmentsmayberequired.
EATON’S CROUSE-HINDS BUSINESS4.16
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Dimensions: Inches (mm)
InstructionManual: 9540
10Kw 15kW 20kW 30kWShippingWeight: 800lbs. 880lbs. 1015lbs. 1170lbs. 363kg. 399kg. 460kg. 531kg.
ShippingVolume: 84cu.ft. 2.37 cu.m.
Technical Data
Renewal Parts
Description PartNumber Description PartNumber
L-828ControlAssembly-1Step* 32323-“Y”-1L-828ControlAssembly-3Step* 32323-“Y”-3L-828ControlAssembly-5Step* 32323-“Y”-5
Fuse,1Amp,Slo-Blo 10047-1205Fuse,1/8Amp,Slo-Blo 10047-1005Fuse,2Amp,Slo-Blo 10047-1141
L-829ControlAssembly-1Step* 32323-1-”Y”-61L-829ControlAssembly-3Step* 32323-3-”Y”-61L-829ControlAssembly-5Step* 32323-5-”Y”-61
Q1&Q2SCR/HeatsinkAssembly,10-20KW 31505-1Q1&Q2SCR/HeatsinkAssembly,30KW 31505-2
Outline Drawing
REGDOutput Percentage (%)
Current (Amps) Light Output
BrightnessStep 3-Step 5-Step 3-Step 5-Step
5 — 6.6 20.0 — 100
4 — 5.2 15.8 — 20
3 6.6 4.1 12.4 100 4.0
2 5.5 3.4 10.3 30 0.8
1 4.8 2.8 8.5 10 0.2
Note:For4,7.5and10kwseriestypeREGDregulators, refer to catalog page 4.3..
FRONTVIEW SIDEVIEW
32.2(818)
LIFTINGEYES
REMOVABLELIFTINGEYES 2.3 (59)
36.0(914)
INPUTWIRING
PORT
FRONTOFUNIT
OUTPUTANDCONTROLWIRING
PORTS
1.3(33)
40.4(1027)
3.0 (76)
DIGITALDISPLAY
CONTROLASSEMBLY
KEYPAD
*Insert1for6.6Aor2for20Ainplaceof“Y”fortheoutputcurrentrequired.
4.17
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CCROConstant Current Regulator Options-
For REGD & REGW Units
ApplicationsTheoptionsdescribedbelowapplytotheCrouse-HindsREGDandREGWconstantcurrentregulators(CCR’s)listedinthecatalog. ManyoptionsmaybecombinedinoneCCR.However,contactCrouse-Hindswhenspecifyingmultipleoptionstoinsurecompatibility
Option Number Description
11 48 VDC Control Voltage (Remote Source) Theregulatorcontrolvoltageis48VDCsuppliedbytheuserfromaremotesource.ThesourceistypicallyaDCpower supplybutitmayalsobebatteries.Thisoptionreplacesthestandardinternal120VACsupply.
16 48VDCControlVoltage(InternalSource) Theregulatorcontrolvoltageis48VDCsuppliedbyabuilt-inpowersupply.Noseparatepowersupplyinthetoweris required.Usingindividualpowersuppliesforeachregulatorlessensthepossibilityofcontrolsystemfailurethanwhen usingasinglecentralsource.Thisoptionreplacesthestandardinternal120VACsupply.
21 On/OffOutputCurrentMonitor Alsocalledsimpleremotebackindication,thisoptionsuppliesasetofdrycontactsforremotemonitoringoftheoutput current.Itprovidesapositivesignaltothetowerthattheconstantcurrentregulatorisreally“on”,thatis,thereiscurrent output to the circuit.
22 IndividualStepOutputCurrentMonitor Thisoptionisremotebackindicationfortheindividualbrightnessstepsoftheconstantcurrentregulator.Itprovides apositivesignaltothetowerthattheconstantcurrentregulatorisreally“on”atthecommandedstep,thatis,there iscurrentoutputtothecircuit.Therearefive(5)normallyopencontactsforbrightnessstepindicationandone(1) normallyopencontactthatmonitorstwofaultconditions:overcurrentandopencircuit.
23T ComputerInterface ThisoptionisusedonlyforFAAL-828regulatorsandprovidessetsofdrycontactsforremotestatusmonitoring. Therearetwo(2)normallyopen/normallyclosedFormCcontactstomonitor:localorremotestatus;andregulator inputpowerindication.(ThisoptionprovidespotentialandcurrenttransformersandrelateditemsforaCROUSE-HINDS computerizedcontrolsystem).
31 LampFailureDetector(829X0only) ThisoptionisusedonlyforFAAL-829regulatorsandprovidesadditionaleight(8)drycontactsforremoteindication fromzerotoeight(8)individualfailedairfieldlightinglamps.
33 EarthLeakage/GroundFaultDetector Cableinsulationresistanceisbasedonsoilconditions,cablelengthandage,andothervariables.Thisoptionwill displayarelativepercentageleakagevalue.Thisoptionmayalsosubstituteforperiodiccircuitmeggerreadingsand providesprogrammablegroundfaultdetectionwithtwo(2)levelsofremotealarmviadrycontacts.Readingsare requestedusingthekeypadandappearontheCCRdigitaldisplay.TheinstallercalibratestheCCRtothe100%value (zeroohms)byshortingoneoutputterminaltoground.Whenfirstconnectedtothecircuit,theinitialreadingrepresents theexistingleakage(typicallylessthan20%).RecordthatinitialpercentagevalueP1asthebaselineandmeasurefuture percentageP2readingsrelativetoit.MeggerthecircuitthefirsttimeandrecordthatvalueasM1.Futuremegger readingsM2areperformedbyreadingP2andusingthefollowingformula:
M2 = M1 ( P1 3 P2 ) 100% = 0 ohmsP1=Initial%readingM1=InitialmeggerP2=Today’s%readingM2=Today’smegger
Theuserdeterminesandsetsthetwo(2)percentagealarmlevels.
Power & Control Equipment
EATON’S CROUSE-HINDS BUSINESS4.18
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Option Number Description
41 DigitalDisplayofLineVoltage&Current Displaysonone(1)metertheregulator’sinputlinevoltsandamps.
42 DigitalDisplayofLineVoltage,LineCurrent&LoadVoltage Combinesthefunctionsofoptions41and44usingtwo(2)meters.
43 DigitalDisplayofLineVoltage Displaysonone(1)metertheregulator’sinputlinevolts.
44 DigitalDisplayofLoadVoltage Displaysonone(1)metertheregulator’soutputseriescircuitvolts.
62 DiscreteStatusIndication(829X0only) ThisoptionisusedonlyforFAAL-829regulatorsandprovidesseven(7)drycontactsforremotestatusmonitoring oftheL-829functions.Withoutthisoption,theL-829alarmsareindicatedonlybyasingleglobalalarmsignal locallyattheregulator.
63T DigitracComputerInterface IntegratedDigitracUnitthatprovidesfullCCRcontrolandL-829monitoring,asdescribedbelow,toa Crouse-HindsAirfieldLightingControlSystem. 1) Loss of input power to the CCR. 2) CCRshutdownbyopen-circuit/over-currentprotectivedevices. 3) Drop of more than 10% in the CCR VA load. 4) FailureoftheCCRtodelivertheselectedoutputcurrent. 5) Thenumberofburnt-outlampsineachseriescircuit. 6) CCR status (local or remote control). 7) The actual CCR output current. 8) TheactualCCRoutputvoltage. 9) The actual CCR output load (wattage). 10) Thestatusofthecomputer-controlledinterposingrelaysthatactivatetheCCR(commandedbrightness acknowledge).
94 PrimarySwitch.2Poles Thestandardprimaryswitchfor2400VinputpowerismadeforaWyeconfiguration,whichconsistsof(1)2400V lineand(1)neutral.ThisOptionprovidesaprimaryswitchforaDeltaconfiguration,whichconsistsof (2) 1200V lines.
S-486 IntegratedMegatrac–REGDLargeDry(pages4.16&4.17) IntegratedMegatracUnitthatmonitorsanddisplaystheinsulationresistancetogroundoftheairfieldlighting seriescircuit.TheMegatracUnitalsoprovidesawarningand/oralarmwhenthecable’sinsulationresistance measurementfallsbelowcustomerselectablethresholds
S-548 IntegratedMegatrac–REGDSmallDry(pages4.14&4.15) IntegratedMegatracUnitthatmonitorsanddisplaystheinsulationresistancetogroundoftheairfieldlighting seriescircuit.TheMegatracUnitalsoprovidesawarningand/oralarmwhenthecable’sinsulationresistance measurementfallsbelowcustomerselectablethresholds
Note: Whereapplicable,thecontactsprovidedforexternalremoteindicationarelimitedtotwo(2)ampsresistiveload. TheexternalwiringandindicatorsarenotsuppliedbyCrouse-Hinds.Improperexternalwiringvoidstheregulatorwarranty.
4.19
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CSSCircuit Selector SwitchCompliances: FAAAC150/5345-5:L-847 UnifiedFacilitiesCriteriaUFC3-535-01
ApplicationsThe CSS Circuit Selector Switch is con-nected to the output of a single con-stant current regulator and switches thatoutputtooneormoreairfieldlighting series circuits. Common applicationsincludecircuitsforPAPIs,stopbars,andtaxiwaycenterlines.TheCSScanalsobeusedastheinterface betweenastandbybackupregulatorandseveraloperatingregulators.
Features � ETLCertified (6.6Ampcircuitsonly)
� SimultaneousorExclusiveSwitching
� For 6.6 or 20 Amp circuits
� LocallyandRemotelyControllable
� Unitsmaybeinterconnected toserveanynumberofcircuitswitha single regulator
� ClearDead-FrontCoverforhigh-voltagecompartment withinterlockswitch
� Wall or Conduit Mounting
� Deenergized Switching to protect regulatorcircuitry
� AmbientTemperatureRange -40°to+55°C
Power & Control Equipment
8 4 7 0 0 --
BasicNumber:
NumberofSeriesCircuits:1 to 4CurrentRating: 66 = 6.6A 20 = 20A(NotCertified)Options:Refertothechartbelow
SelectionChart:StandardFeatures&OptionsSelectonestandardfeatureoroptionwithineachgroup.Ifthetotalnumberofoptionsselectedexceedstwo(2),consultCrouse-Hindsfordeterminationofcompatibility.
GROUPA:INPUTVOLTAGE StandardFeature 120V,50/60Hz Option-2 220-240V,50/60Hz Option-15 480V,50/60HzGROUPB:CONTROLVOLTAGE StandardFeature 120V(InternalSource) Option-3 48VDC(RemoteSource) Option-4 120V(RemoteSource) Option-11 24VDC(RemoteSource)GROUPC:STATUSINDICATION StandardFeature NoStatusIndication Option-5 On/Off6.6ACircuitCurrentMonitor–ForfeedbacktoALCMSGROUPD:CIRCUITSELECTION StandardFeature Simultaneous:Anycombination Option-8 Exclusive:Onecircuitatatime Option-9 SpareRegulatorSwitching:Prevents InterconnectionofthetwoCCRs(2-circuitonly)GROUPE:CABINETTYPE StandardFeature NEMA1–Indoor(Painted) Option-10 NEMA4–Indoor/Outdoor(Painted) Option-12 CabinetDoorInterlockSwitch Option-13 NEMA4X–Indoor/Outdoor(StainlessSteel) Option-14 WithoutCabinet
Ordering InformationHowtoOrder:Tothebasiccatalognumber,addthenumberofseriescircuitstobeswitched andoptionsfromthechartbelow.
Examples:An84700-2-3-5isatwo-circuitselectorswitchforusewith48VDCremotecontrol. Itfeaturesarelayforon/offremotebackindication.
-
EATON’S CROUSE-HINDS BUSINESS4.20
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Renewal Parts
Description PartNumber Description PartNumber
Control Transformer 220/120 (84700w/Option2) 10047-1444CurrentSensingCircuitBoard (84700-1or3w/Option5) 31978-1CurrentSensingCircuitBoard (84700-2or4w/Option5) 31978-2Fuse2.0Amp(84700-1or2) 10047-1590Fuse3.0Amp(84700-3or4) 10047-1591K1andK2RelayModuleAssembly 30848-1RelayK1SPNC 34197
RelayInterfaceAssembly 34195*RelayInterfaceHarness 32849*RelayModuleK2DPNO 34196*TimingCircuitBoard(84700-1or2) 31955-1TimingCircuitBoard(84700-1or2, w/Option3) 31955-6TimingCircuitBoard(84700-1or2, w/Option8) 31955-3TimingCircuitBoard(84700-3or4) 31955-2TimingCircuitBoard(84700-3or4, w/Option3) 31955-7TimingCircuitBoard(84700-3or4, w/Option8) 31955-4
*Theseitemsmustbeorderedtogether
Wiring Diagrams
Outline Drawings
Dimensions: Inches (mm)
InstructionManual: 9131
-1-2 -3-4ShippingWeight: 70.0lbs. 95.0lbs. 31.8kg. 43.2kg.
ShippingVolume: 3.4cu.ft. 5.0cu.ft. 0.096 cu.m. 0.142 cu.m.
Suggested Conduit EntrancesA = Control PowerB=RegulatorC = Series Circuit
FRONTVIEW SIDEVIEW
CABINETSIZE24.0HX20.0WX8.0D(610X508X203)
B B
AA
CCCCCC
14.0(356)
24.0(610)
25.5(648)
25.5(648)
CABINETSIZE24.0HX30.0WX8.0D(610X762X203)
CABINETSIZE24.0HX20.0WX8.0D(610X508X203)
B B
AA
CCCCCC
14.0(356)
24.0(610)
25.5(648)
25.5(648)
CABINETSIZE24.0HX30.0WX8.0D(610X762X203)
4.21
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
RCRadio ControllerCompliances: FAAAC150/5345-49:L-854 NASAOGuidelines
ApplicationsThe Radio Controller permits the remote activationoftheairportlightingsystembythepilot.Thisisaccomplishedbykeyingtheaircraft’smicrophoneinaparticularse-quenceatadesignatedfrequency.Forthe1stepradiocontrollerthesystemisactivateduponreceivingaseriesofpulsesofradiofrequencyenergywithina5secondperiod.Afterreceiptoffivepulsestherelaycloses.The solid state timer will continue to oper-ate for 15 minutes after which it will cause thesystemtoreverttotheoriginal“off”condition.Thetimerisresetbythereceiptoffivepulsesatanytime,reinitiatingthe15minute“run”cycle.Theoperatingtimemaybeselectedin 15 minute increments from 15 minutes to 1 hourbysettingswitchesonthe TimerBoard
For the 3 step radio controller the systemsisactivateduponreceiving aseriesofpulsesofradiofrequency energywithinafivesecondperiod.Atthethirdpulsethefirstrelaycloses,atthefifthpulsethesecondrelaycloses,attheseventhpulsethethirdrelaycloses.Atanytimethepilothastheoptionofsendingthree,five,orsevenpulsestocommandtheintensityleveltohisdesires.Thesystemwillremainattheintensityofthelastcommandreceived.The solid state timer will continue to oper-ate for 15 minutes after which it will cause thesystemtoreverttothe“off”condition.TheTimerisresetbythereceiptofanycommandatanytime,re-initiatingthe15minute“run”cycle.
Features � ETLCertified
� Frequency:118to136MHz TheUNICOMfrequencyof122.8MHziscommonlyselected
� Outdoor Enclosure
� Whip or Remote Antenna
� InputVoltage:120V
� Solid-StateCircuitry
� AmbientTemperature:±55°C
Power & Control Equipment
Ordering InformationEachcontrollerincludesanantenna.Ifdesired,specifybydescriptionaremoteantennawith 50feet(15m)ofcoaxialcable.Specifytheradiofrequency.
RCproductsaremanufacturedbyControlIndustries
Description PartNumber
RadioControllerfor1Step RC-1T2ARadioControllerfor3Step RC-1T5ARegulatorInterfaceUnit RIU-1200*
* AregulatorinterfaceunitisnotrequiredfortheoperationofanyCrouse-Hindslatemodelregulator.
Outline Drawings
8.00(203)
10.00(254)
12.75(324)
12.00(305)
Receiver,Decoder,Tuner,andPower Supply
R3
R2
R1
CAP.
CONTROL 1CONTROL 2CONTROL 3120 VAC
5/16˝ DIA. MTG. HOLE4 PLACES
NEUTRAL
ANTENNA
FUSE
POWERTRANSF.
LED INDICATORS
Depth = 5.00 (127)
Dimensions: Inches (mm)
ShippingWeight: 18.0lbs. 8.2kg.
ShippingVolume: 0.62cu.ft. 0.018 cu.m.
EATON’S CROUSE-HINDS BUSINESS4.22
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
SPCSeries Plug Cutout Type S-1Compliances: FAA AC 150/5340
ApplicationsTheSeriesPlugCutoutTypeS-1isadeviceinstalledattheconstantcurrentregulator (CCR) output through which the series circuit passes. With the handle assemblyremoved,theSPCisolatestheCCRoutputfromairfieldseriesloopformaintenancepersonnelsafety.TheSPCalso shorts the series loop and shorts theregulatorsecondaryaidinginmain-tenancechecksandtroubleshooting.*
Features � Providespositiveproofthattheseriescircuitcannotbeenergizedduringmaintenance
� Shorts the series circuit for mainte-nancecontinuitychecks
� Shortstheregulatorsecondaryformaintenancechecks
� Bodyconstructedofhighstrengthengineered plastics
� Suitablefor6.6Aor20Acircuits � Protected against arcing
Power & Control Equipment
Renewal Parts
Description CatalogNumber
HandleAssembly 30779
Dimensions: Inches (mm)
InstructionSheet: 9208
ShippingWeight: 4.0lbs. 1.8kg.
ShippingVolume: 0.2cu.ft. 0.006 cu.m.
CatalogNumber:
Ordering Information
3 0 7 7 5
Wiring Diagrams
Outline DrawingsBODY
HANDLE/COVERASSEMBLY
9.25(235)
4.50(114)
6.38(162)
8.25(210)
4.25(108)
MOUNTING HOLE/SLOT0.41 x 0.62(10 x 16)
ENTRANCELOCATION FORSERIES LOOP CABLES
ENTRANCELOCATION FORCCR CABLES
* PrimarypowertotheCCRshouldalwaysbeshut-offandlockedoutbeforeremovingthehandleassembly.
S PC2
4.23
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
TRANSFORMERSSeries Isolation TransformersCompliances: FAAAC150/5345-47:L-830&L-831 ICAODesignManual,Part5 USMilitary STNA(France) CSA (Canada) IAF(India)
ApplicationsIsolationtransformersareusedinseriesairfieldandhighwaylightingcircuitstoelectricallyisolatethelightingfixturefromthemediumvoltageusuallypresent.Specialtytransformersarealsoavailablefornon-standardapplications.Thetransformersaretotallyencapsulat-edinTPRRubberand,whenappliedwith proper connections, are suit-ablefordirectburialinthesoil.
Features � ETLCertified
� MilitaryTransformerscomplywithMIL-T-27535
� TotallyEncapsulated
� PrimaryLeads(2)withplugandreceptacle
� SecondaryLead(1)withtwowirereceptacle
� For a grounded core and second-ary,add(-GRS)tothecatalognumber.(ContactCrouse-Hindsforsuitabilityandavailabilityofthis option.)
Power & Control Equipment
Ordering Information
Catalog Nominal Primary Secondary Number Wattage Rating Rating Specification
FAAIsolationTransformersL-83060Hz TA010666-XX 10/15 6.6A 6.6A FAA TA025666-XX 20/25 6.6A 6.6A FAA TA045666-XX 30/45 6.6A 6.6A FAA TA045266-XX 30/45 20A 6.6A FAA TA065666-XX 65 6.6A 6.6A FAA TA10066D-XX 100 6.6A 6.6A FAA TA100266-XX 100 20A 6.6A FAA TA150666-XX 150 6.6A 6.6A FAA TA150266-XX 150 20A 6.6A FAA TA200666-XX 200 6.6A 6.6A FAA TA200266-XX 200 20A 6.6A FAA TA300626-XX 300 6.6A 20A FAA TA300226-XX 300 20A 20A FAA TA300666-XX 300 6.6A 6.6A FAA TA300266-XX 300 20A 6.6A FAA TA500626-XX 500 6.6A 20A FAA TA500266-XX 500 20A 20A FAA TA500666-XX 500 6.6A 6.6A FAA TA500666-XX 500 6.6A 6.6A FAA TA200GH6-01/10 200 5.5A 6.2A FAA TA300GH6-01/10 300 5.5A 6.2A FAA
FAAIsolationTransformersL-83150Hz TA010665-XX 10/15 6.6A 6.6A FAA TA025665-XX 20/25 6.6A 6.6A FAA TA045665-XX 30/45 6.6A 6.6A FAA TA045265-XX 30/45 20A 6.6A FAA TA065665-XX 65 6.6A 6.6A FAA TA10066D-XX 100 6.6A 6.6A FAA TA100265-XX 100 20A 6.6A FAA TA150665-XX 150 6.6A 6.6A FAA TA150265-XX 150 20A 6.6A FAA TA200665-XX 200 6.6A 6.6A FAA TA200265-XX 200 20A 6.6A FAA TA300625-XX 300 6.6A 20A FAA TA300225-XX 300 20A 20A FAA TA300665-XX 300 6.6A 6.6A FAA TA300265-XX 300 20A 6.6A FAA TA500625-XX 500 6.6A 20A FAA TA500265-XX 500 20A 20A FAA TA500665-XX 500 6.6A 6.6A FAA TA500265-XX 500 20A 6.6A FAA
xx-suffix:01“TennisBall”FAAL823Style8“forfrangiblecouplinglightfixtures” -10“Straight”FAAL823,Style7
-01STYLE8 -10STYLE7
EATON’S CROUSE-HINDS BUSINESS4.24
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Technical Data
10-25WTransformer
30-65WTransformer
100-150WTransformer
150-500WTransformer
4.25
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CKPPrimary Connector KitsCompliances: FAAAC150/5345-26:L-823 ICAOAnnex14
ApplicationsThe connection of series isolation transformerstothepowercablesrequiresprimaryconnectorkitsthatcanbeappliedtocableendsinafewminutesbytheelectricalinstallerfol-lowing simple illustrated instructions.
Metalplugandreceptaclefittingsarecrimped onto the conductors and theninsertedintothemoldedrubberhousings.
Primarykitsprovidebothaplugandareceptacle.Onekitisrequiredforeachtransformer location for the ends of theseriescable.
Thecircuitsmaybereadilydisconnect-edfortestingorforreplacingfaultyequipmentandthenquicklyrejoinedforcontinueduse.Typically,L-823con-nections are taped and/or sealed using heatshrinkkits(HSK).RefertotheToolsandMarkersSectionforCablePenciller and Crimping Tools.
CKPProductsaremanufacturedbyAmerace
Power & Control Equipment
*54ClassicKitOnly-includesmoldedrubberadaptersaspartofkitBforsmalldiametercables.
Diametersvaryalongcablelengths.Takeseveralmea-surements.Selectatightfitratherthanalooseone.
*CableSizeTable
CableOutsideDiameter
SymbolWandY
Minimum Maximum
mm inches mm inches
5.0 0.195 6.6 0.260 B*
6.4 0.250 8.4 0.330 C
8.1 0.320 10.9 0.430 D
10.7 0.420 14.9 0.585 E
**ConductorSizeTable
Conductor Size
SymbolWandY
Concentric Stranded Solid
mm2 AWG mm2 AWG
4-6 10-12 4-6 8-10 6
10 8 10 6 4
16 6 16 4 3
- 4 - - 2
*54KitsOnly
ConnectorType: 52 = L-823SceenedCable 54 = L-823UnscreenedCable
PrimaryKitType:LeaveBlankforClassicKit S = ExtraColdShrinkSeal(54Only) SB = BareContinuityWire(52Only) SI = InsulatedContinuityWire(52Only)
ReceptacleCable: W = CableSize* X = ConductorSize**
PlugCable: Y = CableSize* Z = Conductor Size**
- -
Ordering InformationTospecifytheproperkitforaninstallation,selectfromthetablesbelowthesymbolswhichmeettherequire-mentsandsubstitutefor(W,X)and(Y,Z)respectively.
Examples:A52-D4-D4isaconnectorkitfor#8strandedconductorandacablediameterof.390inch.
EATON’S CROUSE-HINDS BUSINESS4.26
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CKSSecondary Connector KitsCompliances: FAAAC150/5345-26:L-823 ICAOAnnex14
ApplicationsSecondaryPlugKitType90PDesignedtomeetFAASpecificationsL-823,Figure4,style4,eachkitformsaplugfortwosingleconductorcablesforconnectiontoasecondaryreceptaclekitor to an isolation transformer. Bothcablesmustbethesamesize.
SecondaryReceptacleKitType90RDesignedtomeetFAASpecificationsL-823,Figure4,style11,eachkitformsa receptacle for two single conductor cablesforconnectiontoasecondaryreceptacleplugkit. Bothcablesmustbethesamesize.
SecondaryPlugKitType91PDesignedtomeetFAASpecificationsL-823,Figure4,style5,eachkitformsaplugforatwoconductorcableforcon-nectiontoasecondaryreceptaclekitorto an isolation transformer.
SecondaryReceptacleKitType91RDesignedtomeetFAASpecificationsL-823,Figure4,style12,eachkitformsa receptacle for a two single conductor cableforconnectiontoasecondaryplugkit.
Power & Control Equipment
ConnectorType: 90 = Terminating 2 single conductors 91 = Terminating2corecable
KitType: P = Plug R = Receptacle
CableSize:SelectSizeSymbolforCableSizeTable1
ConductorSize:SelectSizeSymbolforConductorSizeTable2
-
Ordering Information
Note: ToorderStyle6Plug&Style8 Connector,consultfactory.
RefertopageToolsandMarkers Section for Crimping Tools.
CKS products are manufactured byAmerace
9
ConductorSizeTable2
ConductorSizeAWGSize
SymbolConcentric Stranded Solid
2mm2 14-16 3mm2 12-14 8
2.5mm2 6
4mm2 10-12 6mm2 8-10 6
6mm2 8 10mm2 6 4
CableSizeTable1
CableOutsideDiameter
Size Symbol
Applicableto Kit
Models
Minimum Maximum
mm inches mm inches
3 0.120 4 0.160 S 90P, 90R
3.9 0.155 5.5 0.205 A 90P, 90R
5.0 0.195 6.6 0.260 B 90P, 90R
6.4 0.250 8.4 0.330 C 90P, 90R
8.1 0.320 10.9 0.430 D 91P, 91R
10.7 0.420 14.9 0.585 E 91P, 91R
14.6 0.575 19.9 0.785 F 91P, 91R
4.27
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
HSKHeat Shrink Kit
ApplicationsTheairportlightingHeatShrinkKitfeaturesamechanicallytoughpolyolefinheat-shrinkablesleeve.ThesleeveisdesignedsothatonediameterwillfitallcommonL-823connector/cablecombinationsincludingcablesassmallas0.360inchdiameter.The1-pieceHSKsleeveisfactorycoatedwithawaterproofsealantattheendsonly,leavingtheL-823connectorcleanandre-enterable.ThemainpurposeistosealtheL-823connector/cablejoint,nottosealtheplug/receptaclemating.The2-pieceHSKhas sealant the full length.
Thecrosslinkedpolyolefinsleeveprovidesexcellent moisture, oil and fuel protection forL-823connectorsusedinL-868andL-867bases,ordirectburied.Thesleevesaretoughandwithstanddirectburialabuse.
Upontheapplicationofheatinexcessof275°F(135°C)thesleevequicklyshrinkstoatightfit,conformingtotheirregu-larshapeoftheL-823connector/cabletransition.Theshrinkingactioncausesthesealanttomeltandflow,forcingitintocon-tactwiththeunder-lyingsurfaces.Uponcooling,thesealantformsapositivebarrierwithhighadhesivestrength.Theprocessiscompletewhenthesealantissqueezedfromtheendsofthesleeveandtheheat-sensitivepaintontheoutsideofthesleevechangescolorfrombluetogray.
Power & Control Equipment
Ordering Information
Description CatalogNumber
HSK(2-piece) 10047-1425
HSK(1-piece) 10047-2154
* Bothpiecescontainthesametotallengthof tubing:16inches(406mm)
ShippingWeight: 0.5lbs. 0.23kg.
ShippingVolume: 0.05cu.ft. 0.0014 cu.m.
RECEPTACLE
PLUGTRANSFORMERLEADS
TAPE WRAPBYOTHERS
PLUGL-823KIT
RECEPTACLEHSKSLEEVE(2-PIECE)
1. Slidethesleeveovercablebefore makingelectricalconnection.Mate connector sections and wipe dirt from connectorandcable.Cleancablewith solventwipe.
2. Pre-heatcablejacket.Beginshrinking atcenter,workingtowardbothends. Useaback-and-forth,sweepingmotion of the torch.
3. Shrinkingiscompletewhenmelted sealantissqueezedfrombothendsof thesleeveandallheat-sensitivepaint haschangedfrombluetogray.
Technical Data
Note: Usethe2-pieceHSKforconnections at the isolation transformer as illustratedbelow.Forcable-to-cable splices,usethe1-pieceHSKto enclose the entire connection.
EATON’S CROUSE-HINDS BUSINESS4.28
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
CACable AssembliesCompliances: FAAAC150/5345-26:L-823 FAAAC150/5345-7:L-824 ICAOAnnex14
ApplicationsAirfieldlightingCableAssembliesareused when the lights and/or isolation transformers are installed remote from theseriesprimarycablelocation.
Features � UsesFAAapprovedL-823
connectors
� UsesFAAapprovedL-824cables
� Factorymoldedforwatertightcon-nectionsbetweenconnectorsandcable
� Anylengthavailable
Power & Control Equipment
PrimaryCableAssembly: 54M =Primary
ConnectorConfiguration: P = Plug(male)connectorStyle2 R = Receptacle(female)connectorStyle9
LengthinMeters:
* Ifbothendsofthecablearetobeterminated,usetwoletters.Ifonlyoneendis tobeterminateduseonlyoneletter.Ifthecableisonlyterminatedononeend, theotherendwillbeunprepared.
-
Ordering Information
5 4 M -
SecondaryCableAssembly: 95M =Primary
ConnectorConfiguration: P = Style1Plug P6 = Style6Plug R7 = Style7Receptacle R8 = Style8Receptacle R8 = Style1PlugandStyle8Receptacle
CableSize†: F= TwoIndividual#12AWG(3.3mm2)thermoplasticinsulated,waterproofwires, rated600voltsbetweencontacts,1500voltstoearth,20amp,90CO.D.12.7mm G= 2/12AWG(3.3mm2)thermoplasticinsulatedwaterproofcable,rated600volts betweencontacts,1500voltstoearth,20amp,90CO.D.12.7mm H= TwoIndividual#16AWG(1.3mm2)thermoplasticinsulated,waterproofwires, rated600voltsbetweencontacts,1500voltstoearth,20amp,90CO.D.3.2mm I= 2/16AWG(1.3mm2)thermoplasticinsulatedwaterproofcable,rated600volts betweencontacts,1500voltstoearth,20amp,90CO.D.9.4mm K= TwoIndividual#14AWG(2.1mm2)Tefloninsulatedwires,rated600volts betweencontacts,1500voltstoearth,20amp,200C,wirescertifiedto UL1199andCSA1A/B L= SameasKaboveexpect#16AWG(1.3mm2)
LengthinMeters:
Availablein1/2meterincrementstoanylength
CAproductsaremanufacturedbyAmerace
- 9 5 M - -
SecondaryCA ConnectorConfigurations
Style8
Style7
Style9Style2
Style1
Style6
PrimaryCAConnectorConfigurations
4.29
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil