power control new

9
MS Power Control Parameter Default Value Ericsson R.V. MTN R.V. Value Range DTXFUL 5 5 0 to 40 INIDES -70 -70 -110 to -47 INILEN 2 2 0, 2 to 5 PMARG 8 6 0 to 20 LCOMPUL 70 50 0 to 100 QCOMPUL 30 60 0 to 60 QDESUL 20 0 0 to 70 QLEN 8 6 1 to 20 SSDES -85 -92 -110 to -47 SSLEN -85 -92 -110 to - 47 REGINT 5 1 1 to 30 BTS Power Control Parameter Default Value Ericsson R.V. MTN R.V. Value Range SSDESDL -70 -90 -110 to -47 QDESDL 20 30 0 to 70 LCOMPDL 70 5 0 to 100 QCOMPDL 30 55 0 to 100 REGINTDL 5 1 1 to 10 SSLENDL 5 3 3 to 15 QLENDL 8 3 1 to 20 SDCCHREG OFF ON ON, OFF BSPWRMIN -20 20 -20 to 50 UPDWNRATIO 200 300 100 to 700 Discrepancies

Upload: yayra-de-souza

Post on 08-Feb-2016

18 views

Category:

Documents


2 download

DESCRIPTION

Attached is a macro for tuning Ericsson parameters for dynamic BTS and MS power control. If you find it useful, kindly let me know please and don't forget the reputation.

TRANSCRIPT

Page 1: Power Control New

MS Power Control

Parameter Default Value Ericsson R.V. MTN R.V. Value RangeDTXFUL 5 5 0 to 40INIDES -70 -70 -110 to -47INILEN 2 2 0, 2 to 5PMARG 8 6 0 to 20LCOMPUL 70 50 0 to 100QCOMPUL 30 60 0 to 60QDESUL 20 0 0 to 70QLEN 8 6 1 to 20SSDES -85 -92 -110 to -47SSLEN -85 -92 -110 to - 47REGINT 5 1 1 to 30

BTS Power Control

Parameter Default Value Ericsson R.V. MTN R.V. Value RangeSSDESDL -70 -90 -110 to -47QDESDL 20 30 0 to 70LCOMPDL 70 5 0 to 100QCOMPDL 30 55 0 to 100REGINTDL 5 1 1 to 10SSLENDL 5 3 3 to 15QLENDL 8 3 1 to 20SDCCHREG OFF ON ON, OFFBSPWRMIN -20 20 -20 to 50UPDWNRATIO 200 300 100 to 700

Discrepancies

B5
Brandon: No. of measurement periods, after a call has been established on a TCH, before the full set of measurements shall be used.
B6
Brandon: Desired initial SS measured by the receiver in the BTS
B7
Brandon: Length of the initial SS filter. Recommended: INILEN < SSLEN
B8
Brandon: Power Margin - used on the new channel at assignment of a TCH, on the old channel at assignment failure or HO failure, and on the new channel at intracell HO and subcell change.
B9
Brandon: How much of the path loss that shall be compensated for
B10
Brandon: The weight of the quality compensation
B11
Brandon: Desired quality level measured by the receiver in the BTS
B12
Brandon: Length of the quality filter
B13
Brandon: Desired signal strength at the outerrim of the regulation area
B14
Brandon: Length of the stationary signal strength filter
B15
Brandon: Minimum time period between two consecutive power orders
B20
Brandon: Target value for desired SS measured by receiver in the MS at outer rim of the regulation area
B21
Brandon: Target value for desired quality measured by receiver in MS (transformed into dB units before used in algorithm)
B22
Brandon: How much path loss that shall be compensated for in the algorithm that regulates towards quality
B23
Brandon: Determines the weight of the quality compensation
B24
Brandon: Defines the regulation interval
B25
Brandon: Defines the length of the frequency plan filter
B26
Brandon: Defines the length of the quality filter
B27
Brandon: Switch for the regulation of SDCCH channels
B28
Brandon: Defines the minimum allowed output power for the BTS on the non-BCCH frequencies
B29
Brandon: ratio between the up and down regulation speed
Page 2: Power Control New

NGBSC1 NGBSC2 NGSBC3 NGBSC4 DBBSC1 DBBSC24 4 4

70 70 -702 26 6

50 5060 600 04 4

92 903 31 2

NGBSC1 NGBSC2 NGSBC3 NGBSC4 DBBSC1 DBBSC290 9030 07 7

70 71 13 33 4

OFF OFF20 -20

300

G8
Brandon: Some using 8
H8
Brandon: 1053A on 16
G9
Brandon: Some using 80
G15
Brandon: Some sites on 2
G22
Brandon: Some on 5
G23
Brandon: Some on 55
G26
Brandon: Some on 4
Page 3: Power Control New

UnitSACCH

dBmSACCH

dB %%

dtquSACCH

dBmdBm

SACCH

UnitdBmdtqu%%

SACCHSACCHSACCH

dBm%

Page 4: Power Control New

unconstrained power order: pu=max(dpu1,dpu2) QDESDLdown regulation in dBs: dpu1= LCOMPDL/100 * ( SSDESDL-SS_filtered)+ QCOMPDL/100 *(QDESDL_dB-Q_filtered) 0

dpu2= 0.3 * ( SSDESDL-SS_filtered)+ 0.4 *(QDESDL_dB-Q_filtered) 102030

to change the chart, 40set parameters values: 50LCOMPDL 5 60SSDESDL 90 70QCOMPDL 55QDESDL 30

implemented param. :

LCOMPDL 5

SSDESDL 90

QCOMPDL 55

QDESDL 30

default param.:

LCOMPDL 70

SSDESDL 70

QCOMPDL 30

QDESDL 20

recomended param.:

LCOMPDL 5

SSDESDL 90

QCOMPDL 55

QDESDL 30 *to change the view - click one of axis corners and drag it.

low signal110 106 102 98 94 90 86 82 78 74 70 66 62 58 54 SScomp (in dBm, absolute value)

23 0 0 0 0 0.8 2 3.2 4.4 4.8 5 5.2 5.4 5.6 5.8 6 6.2

19 1 0 0 0 0 0.4 1.6 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4

17 2 0 0 0 0 0 0.8 1.3 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9

15 3 0 0 0 0 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8

13 4 0 0 0 0 0 0 0 0 0 0 0 0.1 0.3 0.5 0.7

11 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

8 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

4 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 bad quality

RxQual_dB RxQual

value in the field is equal 0

01

23

45

67

0

5

10

15

20

25

30

110106

10298

9490

8682

7874

7066

6258

54

1101061029894908682

RxQual

dp

u(R

xQu

al,

SS

)

SS

Page 5: Power Control New

value in the field is greater then 0

Page 6: Power Control New

QDESDL_db231917151311

84

SScomp (in dBm, absolute value)

Page 7: Power Control New

unconstrained power order: pu= MSTXPWR - dpudown regulation in dBs: dpu= LCOMPUL/100 * ( SScomp- SSDES)- QCOMPUL/100 *4/10 *( Q_AVE- QDESUL)

to change the chart,set parameters values:LCOMPUL 55SSDES 92QCOMPUL 60QDESUL 0

implemented param. :

LCOMPUL 50

SSDES 92

QCOMPUL 60

QDESUL 0

default param.:

LCOMPUL 70

SSDES 85

QCOMPUL 30

QDESUL 20

recomended param.:

LCOMPUL 50

SSDES 92

QCOMPUL 60

QDESUL 0 *to change the view - click one of axis corners and drag it.

MTNNimplemented param. : low signalLCOMPUL 55 102 98 94 90 86 82 78 74 70 66 62 58 54 50 46 SS (in dBm, absolute value) SSDES 92 0 0 0 0 1.1 3.3 5.5 7.7 9.9 12.1 14.3 16.5 18.7 20.9 23.1 25.3

QCOMPUL 60 1 0 0 0 0 0.9 3.1 5.3 7.5 9.7 11.9 14.1 16.3 18.5 20.7 22.9

QDESUL 0 2 0 0 0 0 0 0.7 2.9 5.1 7.3 9.5 11.7 13.9 16.1 18.3 20.5

3 0 0 0 0 0 0 0.5 2.7 4.9 7.1 9.3 11.5 13.7 15.9 18.1

4 0 0 0 0 0 0 0 0.3 2.5 4.7 6.9 9.1 11.3 13.5 15.7

E/// recommend param. : 5 0 0 0 0 0 0 0 0 0.1 2.3 4.5 6.7 8.9 11.1 13.3

LCOMPUL 6 6 0 0 0 0 0 0 0 0 0 0 2.1 4.3 6.5 8.7 10.9

SSDES 95 7 0 0 0 0 0 0 0 0 0 0 0 1.9 4.1 6.3 8.5 bad qaulityQCOMPUL 75QDESUL 30 RxQual

value in the field is equal 0value in the field is greater then 0

01

23

45

67

0

5

10

15

20

25

30

10

2 98 9

4 90 8

6 82 7

8 74 7

0 66 6

2 58 5

4 50 4

6

10298949086827874

RxQual

dp

u(R

xQu

al,S

S)

SS

Page 8: Power Control New

SS (in dBm, absolute value)

Page 9: Power Control New

Lp=10*log10(P/P_ref) [dBm] -> P_ref=1 mW

P/P_ref= 210*log(2)= 3.010299957