power field services hwx ecofit tm
TRANSCRIPT
Power Field Services
HWX ECOFIT TM
We help to define and implement the best
modernization solution, giving access to new
features
⚫ Retrofit and ECOFIT solutions
⚫ Modernization solutions
⚫ Infrastructure technology enhancement to comply with
latest regulations
⚫ Standard exchange programs
⚫ Revitalization programs
⚫ Upgrade equipment with new technologies
⚫ Enhance Cybersecurity
Power Field Services - Renew
Type of Modernization Services
Page 3Confidential Property of Schneider Electric |
• ECOFIT Solutions & Direct Replacement: Schneider pre-engineered retrofit solution for LV
and MV equipment
• Adaptation & Upgrade: addition of new feature
(Asset connect, sensors, new CT/VT)
• Revamping: Complete
Replacement/Modernisation Solutions
• Panel extension: extension by an identical one
or by currently commercialized switchgear
LV Renew MV Renew MV Relay
HWX Range
● Horizontal Isolation and Horizontal
draw out type VCB
● Floor Rolling
● System voltage till 12kV
● Continuous Current upto 5000A
● Breaking Capacity -50kA
● Short time current for 3 sec upto 50KA
● Internal Arc 40kA for 1sec
One of the Most widely sold MV
Switchgear range in India!
At minimum capex investment:
Upgrade legacy HWX circuit breakers with the latest technology using the HVX circuit breaker as a
direct replacement which offers higher reliability, longer spares support & more options for digital
features helping to increase the equipment lifespan and safety as well as help reduce risk of
failure.
Peace of mind through modernization expertise.
Page 5Confidential Property of Schneider Electric |
Value Proposition
Confidential Property of Schneider Electric
What are the benefits of ECOFIT™?
Cost
*Average time assessed by Field services representative
ECOFIT Life cycle
Confidential Property of Schneider Electric |
Initial
installation
End of
CommercialisationEnd of full spare
parts availability
Discontinuation
of spare parts
End of ECOFIT
commercialisation
End of ECOFIT
Spare parts
Original product
ECOFIT
Start of ECOFIT
Commercialisation
ECOFIT starts a new life cycle
Page 7
Ecofit Solution
Rated voltage :- 12 kV
Rated current :- 1250 A
STC :- 40KA/3 Sec
Rated frequency:- 50/60 Hz
Power freq. HV :- 28 kVrms/ 1 min sec
Impulse voltage :- 75 kVpeak
HWX-O EXISTING CB HWX-O WITH HVX-ROF RETROFIT CB
Page 9Confidential Property of Schneider Electric |
Ecofit solution
Complying to all safety
interlocks as per IEC/IS
Closed Door feature
enabled
Verification & Validation
Page 10Confidential Property of Schneider Electric |
Tests Test parameter Sample
No load characteristic of VCB
Timing and Speed CB
Mechanical operation test
100 Operations CB
JIG Test Alignment Check CB
Contact resistance At 100A DC CB and Panel
High Voltage Test At 28 kV for 1 minutes CB and Panel
Check of Interlock As per standard CB and Panel
Applicable IEC: 62271-100, 62271-1,62271-200
• All above test done at Ecofit as part of
verification plan.
• Timeline – One week (Week 2 Dec 2020).
Tests Test parameter Sample
Lightning Impulse test 75kVp VCB with Panel
Power Frequency test 28kv rms/1min VCB with Panel
Temperature Rise test 1250A VCB with Panel
Short Time withstand Current
40kA for 3s VCB with Panel
Mechanical & Electromechanical Operation Test
As per Standard VCB with Panel
Validation Plan @ Test LabVerification @ Ecofit
• All tests done at ERDA, Vadodara.
Applicable IEC: 62271-100, 62271-1,62271-200
Connected ready
Page 11© 2019 Schneider Electric, All Rights Reserved |
EcoStruxure Power
Scada Operation
EcoStruxure
Asset AdvisorEcoStruxure
Facility Advisor
EcoStruxure Power
Monitoring Expert
HMI (Substation
Monitoring Device)
Connect Products
Equipment Level
Edge Control
Facility Level
Apps and Analytics
Cloud Services Level
TH110
CL110
Arc flash
Zigbee / NFC Tag
Arc flash in MV switchgear
# Possibility of Arc Flesh during Manual Rack IN/OUT operation
# Inbuilt Motorize rack In/Out operation prevent any human injury
# Promotes unmanned substation
How arc flash create the situation during manual Rack IN/OUT operation
How The Inbuilt motorized racking feature works
To enhance SAFETY
Motorised Rack in–out feature
Upgraded Spare
HVX
HWX Panel
At Customer site*Panel Door to be replaced for closed door operation feature
Connected Ecofit CB
HVX Connected
HWX Panel
At Customer site*Panel Door to be replaced for closed door operation feature
With Motorised Racking
Ecofit++ Package your solution for
complete safety upgrade
Easergy P5Ecofit
Micom
HVX Connected
With Motorised Racking
With Arc Flash Protection
HWX Panel
At Customer site*Panel Door to be replaced for closed door operation feature
New Connected HWX Panel with HVX & Easergy : For
extension & replacement
Easergy P5
HVX Connected
New HWX Panel
From Ecofit
With Arc Flash Protection
ECOFIT vs competition
Confidential Property of Schneider Electric | Page 17
• Engineered solution with =S= warranty
• Type tested solution for improved safety
• Shorter downtime
• Manufacturer’s expertise and experience
• Qualified and trained FSR
• Associated spare parts (CB & switchboard)
• High maintenance capability
• Connected assets
• Asset Management Services
• Engineered solution with =S= warranty
• Type tested solution for improved safety
• Schneider equipment’s expertise &
experience
• Associated spare parts (CB & switchboard)
• Connected assets & Asset monitoring
Services
Local Panel Builder / Contractors
targeting
Schneider Installed base
Manufacturers
targeting
Schneider Installed base
New Business Model : Modernisation as a Service
Value Proposition –No Capex, New Assets
A) Service Plan (Multi Year Maintenance Contract)
• Maintain & support with spares as much as possible
• 24/7 hotline & Emergency onsite support
commitment
B) Modernization + Digital Services of selected assets
as per scheduled plan
• Replacement of Asset
C) Customer pays over 3/5 Years (Quarterly or Yearly)
Extend obsolete assets lifespan by maintaining in operation some extra years
and
replace by new range before the end of contract period
Advantage
Service Plan
Modernization
FSR
Visit
Preventive &
Breakdown
maintenance
support
Factory
Warranty