power | no-break : sys 33, by sensys group
TRANSCRIPT
Mission Critical Applications
INFINITE POWER
UPSUNINTERRUPTIBLE POWER SUPPLY
From 10 kVA to 300 kVA
Sys 33
Full IGBT double conversion technology allowingit to provide extraordinary savings, while at the same
time leading first class load protection
UPS 3 PHASE
IGBT Rectifier DesignDouble Conversion
True On-Line-VFI Green Power AvailabilityReliabilityEfficiency
GROUP
02
Data Center
IT Rooms
Manufacture Line
Process Units
Hospital Operating Rooms
Medical Equipments
Magnetic Equipments
Laboratory Systems
Security Systems
Financial Systems
Transportation & Infrastructure
Television Systems
Broadcasting and Transmission
Equipment
Radio and Telecommunication
Lighting and Emergency
Call Centre
Applications
Our task is to be a global leader, both in technology and engineering, to provide innovative solutions and expertisein reliable power, precision cooling systems, embedded computing, integrated racks and enclosures, power switching and controls, renewable energies, emergency and security, monitoring, management and connectivity. To follow the needs of today’s business, SENSYS offers a complete portfolioof critical power products and services, from basic UPSto engineered power systems, and from basic batterymaintenance to comprehensive service contracts covering every aspect of your power quality.
Maximized to guarantee reliability and availability, provides the best power protection technology for modern mission criticalIT and electronic loads.
The SYS-33 series is a three phase unit UPS, VFIdouble-conversion, full IGBT design and DSP in inverter/rectifier that features high efficiency up to 94.3%.
In addition is designed with increased power factor correction PFC (>0.99) and low THD(i) (down to 3%).
With an industry-leading, the SYS-33 series delivers remarkably low total cost of ownership in terms of both system and operation cost.
Sys 3310 kVA to 300 kVA
• Capability to supply loads with capacitive PF – Output PF
• Operates in VFI mode (Voltage Frequency Independent) compliant
the maximum levels of power reliability for all mission-critical processes.
• Intelligent design provides easy maintenance and installation
• Fault tolerance with built-in maintenance and static bypass
• Multi language LCD display
• Wide input voltage range
• Battery management system (extends battery lifetime)
• Optional model with built-in galvanic isolation transformer
• High overload capacity to improve downstream discrimination
• Redundant auxiliary power and control circuit ensures higher reliability
• Easy integration with networking (TCP/IP-SNMP) and BMS systems
• Energy savings up to 94.3% - high efficiency in battery or normal mode even at low % of load for lower operation costs
• Green power design allows to work at maximum efficiency by offering a new benchmark according to the load requirement
• Eco Mode permits an overall efficiency of 97%
• Small footprint
• High input power factor (PF>0.99) and low harmonic distortion (THD down to 3 %), saving in installation costs
• Fully compatible with generator installation
• Evolution and redundancy N+1 guaranteed by on site Parallel Ready
• Ergonomic design to enable easy diagnostic
03
Lowest TCO - (total cost of ownership)
Flexibility and Availability Power
SYS-33 series is a transformerless UPS designed to help your business, making it the perfect solution for continuous availability, flexibility, serviceability and performance. This system, DSP microprocessor controlled, much faster than the standard microprocessor, is able to deliver 10kVA up to 300 kVA of power in different sizes to suit the marketrequirements.
Sys 3310 kVA to 300 kVA
04
Technical Specifications
Topology : true on-Line, double conversion, VFI (Voltage and Frequency Independent) - EN 62040-3Technology : full IGBT, DSP controlled, redundancy design, continuous operationConstruction : available 10 up to 300 kVAOperating modes : double conversion, automatic bypass, frequency converter and parallel operation
Output power rating (kVA)
Nominal active power (kW)
Dimensions (*)
Weight (kg)
Efficiency - AC/AC
Efficiency - Eco Mode
Standards
Input voltage
Input voltage range
Input frequency range
Input power factor
Input current harmonic distortion
Output voltage
Output frequency
Output Voltage Wave Form
Output voltage
Output voltage THD at linear load
Overload
Link DC Voltage
Operating Range
Interface standard
Optional interface acces
Emergency power off
Bypass
Parallel kit
Dual input connection
10 15 20 30 40 60
8 12 16 24 32 48
410 x 800 x 1100 550 x 900 x 1400
105 120 120 130 185 205
Up to 93.4 %
Up to 97 %
EN 62040-1 (safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111)
380/220 , 400/230 , 415/240 (3 Phase, 4-wire plus ground) Vac
100% load ≈ 320Vac – 480Vac |50% load ≈ 210Vac – 480Vac |30% load ≈ 140Vac – 480Vac
50-60 Hz ± 10%
0.99
THD(i) down to 4% (CLEAN input)
380/220 , 400/230 , 415/240 (3 Phase, 4-wire plus ground) Vac
50-60 Hz ± 0.01% free running mode
Sine Wave
< 1%
< 3%
125% : 10minutes ; 150% : 1minute
± 372 Vdc
UPS: 0 ºC +40 ºC / Battery: 20-25 ºC
RS232, Smart Slot, RS485, Dry contacts, Generator port
SNMP card, Modbus card
Local and remote
Built-in static and manual bypass
Redundancy N+1 up to 4 units with parallel kit (optional)
Bypass and rectifier separated
(*) dimensions with casters
(optional)
Sys 3310 kVA to 300 kVA
05 (*) dimensions with casters
Technical Specifications
Topology : true on-Line, double conversion, VFI (Voltage and Frequency Independent) - EN 62040-3Technology : full IGBT, DSP controlled, redundancy design, continuous operationConstruction : available 10 up to 300 kVAOperating modes : double conversion, automatic bypass, frequency converter and parallel operation
Output power rating (kVA)
Nominal active power (kW)
Dimensions (*)
Weight (kg)
Standards
Input voltage
Input voltage range
Input frequency range
Input power factor
Input current harmonic distortion
Output voltage
Output frequency
Output Voltage Wave Form
Output voltage
Output voltage THD at linear load
Overload
Link DC Voltage
Operating Range
Interface standard
Optional interface acces
Emergency power off
Bypass
Parallel kit
Dual input connection
80 100 120 160 200 250 300
64 80 96 128 160 200 240
670 x 730 x 1630 850 x 780 x 1820
960 x 870 x 1860 1340 x 1080 x 1950
255 285 350 525 570 735 750
EN 62040-1 (safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111)
100% load ≈ 320Vac – 480Vac |50% load ≈ 210Vac – 480Vac |30% load ≈ 140Vac – 480Vac
50-60 Hz ± 10%
0.99
THD(i) down to 3% (CLEAN input)
380/220 , 400/230 , 415/240 (3 Phase, 4-wire plus ground) Vac
50-60 Hz ± 0.01% free running mode
Sine Wave
< 1%
< 3%
125% : 10minutes ; 150% : 1minute
± 372 Vdc ± 360 Vdc
UPS: 0 ºC +40 ºC / Battery: 20-25 ºC
RS232, Smart Slot, RS485, Dry contacts, Generator port
SNMP card, Modbus card
Local and remote
Built-in static and manual bypass
Redundancy N+1 up to 4 units with parallel kit (optional)
Bypass and rectifier separated (optional)
Efficiency - AC/AC
Efficiency - Eco Mode
Up to 94.3 %
Up to 97 %
380/220 , 400/230 , 415/240 (3 Phase, 4-wire plus ground) Vac
Sys 3310 kVA to 300 kVA
www.sensysgroup.com
GROUP